Home
User Manual
Contents
1. RS 485 eS I If you are going to chain multiple illuminators use the D N status cable to make the connection D N Status Connector Pin Assignment D N Status Pin Name 1 VIDEO 2 GND 3 NC 4 COM 5 6 NO X Please refer to the diagram below for connection and make required DIP Switch settings Up to 127 illuminators can be chained D N Status Cable D N Status Cable Item DIP Switch Settings Illuminator ID SW2 Pin 1 7 1 2 3 RS 485 SW1 Pin 4 OFF OFF ON Telemetry SW2 Pin 8 OFF ON ON 2 Installation 2 2 Traffic Camera Application Connection for D N and Video Sync Illuminator as master If you are going to connect the illuminator to a traffic camera use a video sync cable op tional to make the connection as below GND amp BW pin Connect the gland side to the TELE VIDEO port on the illuminator e Terminate the other end of the cable Pin 5 amp 6 to the GND amp BW pin of the camera Terminate the video end of the cable Pin 1 amp 2 to the VIDEO port of the camera Video Sync Connector Pin Assignment Pin
2. X 10 2 1 Making the C0 8CV06 Misiccs orte ner niani iaaa aaia nix Rcs 10 2 2 Traffic Camera Application xoa eise 13 Remote Control 15 4 Specification E EET 17 1 Introduction 1 Introduction 1 1 Package Contents The package includes these items High Power Intelligent IR Illuminator xi CD ROM Remote Control Utility and User Manual x1 User Manual x1 Hexagonal Wrench x1 2 pin Screw Terminal Block x1 m Video Sync Link Cable optional xi W D N Status Cable optional x1 W Mains Input PSU 1 2 Hardware Overview 1 2 1 Dimensions e 233mm 9 17 e 167mm 6 57 9 c A gt N 5 g 8 m RO Ld E C S 176mm 6 93 1 Introduction 1 2 1 Part Names Photocell Sensor Pressure equalization valve D N Status For D N status Output AC24V DC12V White AC24V DC12V Black RS485 White RS485 Orange LED Failure_COM Red LED Failure_NO Green LED Failure_NC Blue TEL
3. efficiency surface mount power LED with advanced current limited integral control circuitry 10 50 20 60 40 80 60 100 300m 984 ft 240m 787 ft 170m 558 ft 130m 427 ft External adjustable by optical diffusion 12VDC 24VAC 50 60Hz 10 55W Max 3M waterproof cable for power input RS485 LEDs failure status Windows Based PC Software LED Power Control Light Sensor Sensitivity Video timing Control Telemetry Enfored IR ON OFF 1M waterproof cable for telemetry IR ON OFF control and Video input 1M waterproof cable for Day Night status output Mains Power Adaptor AC100 240V to DC12V Robust high quality aluminum extrusion Highly IR transmitted polycarbonate with enhanced surface protection 4 Specification 50 60oC 58oF 140 OF 50 60 C 4oF 140 OF 70 MAX 233 x 310 x 220 mm 9 17 x 12 2 x 8 66 5 6Kg 12 316 4 Specification h I
4. E VIDEO For telemetry IR ON OFF control and Video input Controls Loosen the 4 screws to expose the controls Mounting Bracket Bracket Knob o Loosen the knob to tilt the bracket 1 Introduction Controls Loosen the four screws securing the panel to 6X pose the controls and make required adjustments Important After setup make sure to lock all four screws tightly in sequence as indicated in the cau tion label after setup to ensure waterproofing 1 Diffuser Position Control Use the provided hexagonal wrench to loosen the screw and move the screw to desired position to adjust the LED beam angles 0 No diffuser to occupy over the LED 3 3 4 ON 2 2 4 ON Diffuser Position Control mum 4 ON wmm 1 1 4 ON wmm 0 OFF ign ark ON swe2 Sensitivity BHBHHBHB 12345678 ON AUTION Please lock all four screws tightly in order illustrated after setup to ensure the waterproof warranty A typical torque of 5 8 kgf cm is suggested e 154 Adjust the position of the diffuser The higher the number the greater the angle of illumination Actual illumination angle depends on the model 2 DIP SW1 Pin 1 3 To sync with the shutter speed of the camera Pin 1 Pin 2 Pin 3 Shutter Speed OFF OFF OFF No allowed O
5. N OFF OFF 1 250 Default OFF ON OFF 1 500 OFF OFF ON 1 1K e PIN 4 To turn on off the RS 485 impedance If you are chaining multiple illuminators set the last one as ON and the rest as OFF 3 DIP SW2 Pin 1 7 To set the ID of the illuminator when chaining multiple illumina tors ID Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 000 OFF OFF OFF OFF OFF OFF OFF 001 ON OFF OFF OFF OFF OFF OFF 002 OFF ON OFF OFF OFF OFF OFF 127 ON ON ON ON ON ON ON Pin 8 Set 8 to be ON to enforce the telemetry ON OFF function of the il luminator 1 Introduction LED Power Using a screwdriver loosen the screw and turn it clockwise to increase the power or counter clockwise to decrease Lo Hi the power LED Power Sensitivity The illuminator will automatically turn on when light ing condition become dark and off when lighting conditions become light To adjust the sensitivity use a screwdriver to turn the clock TO Dark wise to decrease the sensitivity or counter clockwise to increase Sensitivity the sensitivity 2 Installation 2 Installation 2 1 Making the Connection It s suggested to set up the illuminator at night for optimized illumination results 1 Attach the illuminator to desired location Use appropriate mounting bracket as required Using a wrench loosen the side bolts and then tilt the illuminator to desired angle Carefully t
6. Name Color Remark 1 VIDEO Brown 2 GND Blue 3 TELE A White SHORT IR OFF SW2 PIN 8 ON 4 TELE B Green OPEN IR ON 5 NO Yellow TELE VIDEO 6 COM Grey Settings Camera side Set the camera s Day Night mode to D N sync so that the camera changes D N mode as triggered by the illuminator Illuminator side Also make sure to set the illuminator s shutter speed as the same as the shutter speed of the camera 2 Installation Chaining up to 3 illuminators with traffic camera When connecting the illuminator to a traffic camera it s allowed to chain up to 3 illumi nators to sync the 3 illuminators D N status and shutter speed with the camera Refer to the diagram below for connection and make required DIP Switch settings Example Sycn to a traffic camera with shutter speed of 1 1000 D N Status Cable Pin Assignment Name VIDEO GND NC COM NO X D N Status rend oo Od oo FT D N Status Cable D N Status Cable Video Sync Cable Item DIP Switch Settings Illuminator ID SW2 Pin 1 7 1 2 3 Telemetry SW2 Pin 8 OFF ON ON Shutter Speed SW1 Pin 1 3 1 1000 1 1000 1 1000 RS 485 SW1 Pin 4 OFF OFF ON 3 Remote Control 3 Remote Control The CD comes with a u
7. User Manual High Power Intelligent IR Illuminator ZEIM 4000643G 080 A 2 Safety Information 1 Before using the product please carefully read through the safety information and operation instructions 2 Take note of the Caution labels Please follow the Caution labels on the product and User Manual to ensure operation safety 3 Cleaning Before cleaning the unit please first unplug the power 4 Peripheral accessories Do not place the unit on an unstable cart tripod or on a tabletop as personal injury and damage to the unit may occur due to a fall Please use officially certified support frames and accessories included with the product Follow the instructions in this Instruction Manual during installation to ensure the quality and maintain safety 5 Power Please follow the labeled specifications on the unit and supply with the cor rect power If unsure of the actual power requirements please contact the distrib utor and do not connect the power at will 6 Power cable The power cable must be properly secured as improper connections may cause a short circuit fire hazards or serious damage and hazards 7 Lightning strike During prolonged inactivity please unplug the power cable and the video cable to avoid damage from lightning strike and power surges 8 Foreign objects and fluids Please do not insert any objects into the unit or spill liquids to avoid short circuits 9 Warning High v
8. ilt the illuminator until the satisfied angle is achieved When it s done make sure to fasten the bolts Connect the illuminator to power supply Ensure that the polarity is correct when using DC power To sync the D N status use the video sync cable optional to make the connec tion Video Sync Connector Pin Assignment Pin Name Color Remark 1 VIDEO Brown 2 GND Blue 3 TELE A White SHORT IR OFF SW2 PIN 8 ON 4 TELE B Green OPEN IR ON 5 NO Yellow TELE VIDEO 6 COM Grey Connect the gland side to the TELE VIDEO port on the illuminator If using illuminator as the master Terminate the other end of the video sync cable Pin 5 amp 6 to the camera s connectors as shown below Make sure to set the camera s related action to D N 2 Installation Video Sync Cable Alarm IN Pin 5 GND Pin 6 GND Pin 5 BW Pin 6 Video Sync Cable If using the camera as the master Terminate the other end of the video sync cable Pin 3 amp 4 to the camera s Alarm Out connectors DIN STATUS 5 Optionally connect the LED failure signals to an alarm device When one of the LED fails you will be automatically informed A 6 7 2 Installation Optionally connect the RS 485 signals to computer for remote control reir T 9 otic
9. les lighting FCC This equipment has been tested and found to comply with the limits for a Class B digi tal device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the follow ing measures Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help u Table of Contents 1 Introduction I I 6 1 1 Package 2 condendi het CERRAR 6 1 2 Hardware OVervieW iis accuse edere here rhe o dx ages ERR T LR 6 _ 33_ _ _ _ lt _ _ _ _ _ __ _ _ 6 1 2 1 7 MM
10. oltage circuitry contained within the unit Do not disassemble to avoid electric shock All maintenance operations must be handled by qualified maintenance staff 10 Maintenance When the following occurs please first power off the unit and then perform maintenance by qualified maintenance staff e Damaged power cable or socket e Liquid spills or foreign objects in the unit e Inoperable unit when proper instructions are followed e Dropped unit or damaged shell e Other anomalies 11 Component replacement Replaced components by the maintenance staff must be official certified parts of identical specifications Using unauthorized components can cause fire hazards and electric shock damage 2N 12 13 14 Safety inspection After the unit maintenance 5 been completed the mainte nance staff must perform safety inspection to ensure proper operation The IR illuminator contains ultra intense LED emitters DO NOT STARE AT THE LED SOURCE Never open or remove the front cover while the IR illuminator is under operation Qualified personnel must perform all maintenance A CE Compliance The IR illuminator has been tested for compliance with CE Conformit Europ enne standards and guidelines and has been found to conform to applicable CE standards specifically e EN61000 6 3 for generic emissions e EN50130 4 for immunity e EN60598 1 for Luminaires e EN60598 2 5 for flood lights EN62471 for LED modu
11. tility to remotely configure the illuminators The utility required no installation Simply copy the executable file to your computer and double click the file to launch the utility From the menu bar click COM PORT and select a com port number according to your connection Check the Enable Remote Control check box and select the ID of the illuminator you want to set up Then make the configurations as required In addition to the settings correspond to the hardware controls of the illuminators you can also set these Sync Delay Adjust the delay for a best illumination condition when video sync is connected Usually the default settings Oms is recommended However you can try to select the parameter that gives optimal lighting so that a best image is Enforce LED ON OFF Externally Check this box to activate the telemetry LED ON OFF function LED Illuminator Controller m FILE COMPORT ABOUT ID List amp Alarm Inf a E ens Ame 3 Remote Control For your convenience you can enter a descriptive name for each illuminator To do so click the Modify ID List to pop up the dialog box Click Start Scan to search for the connected illuminators Then select the ID of target illuminator to modify the location name After entering the settings click OK Then wait a moment for the update to take effects Modify ID LOCATION 4 Specification 4 Specification High
Download Pdf Manuals
Related Search
Related Contents
FNQ-A_4PDE393319-1 Gardena SchnippSchnapp HyperFlex 12G - venue lighting effects Manual de referencia de escáner SICA20F2P 取扱説明書 SECTION A ---NÉCESSITÉS COURANTES DE LA VIE Manual de Instalação de VPN em Ambiente Windows RM-AV2500T User Manual and Transparency Document Copyright © All rights reserved.