Home

User Manual

image

Contents

1. adjacent to low water cutoff A 5 Adjust thermostat to highest setting 6 Check main burner flames See Figure 10 or 11 Flame should have clearly defined inner cones with no yellow tipping Orange yellow streaks caused by dust should not be confused with true yellow tipping If yellow flames are observed follow instructions TO TURN OFF GAS TO APPLIANCE see Figure 4 5 or 6 and contact a qualified service agency 7 Adjust thermostat to normal setting Figure 7 Typical Vent System Installation PILOT INCANDESCENT OUTER MANTLE BLUE WITH OC L ORANGE F SHING _ 3 8 9 5 mm OUTER CONE gt A DARKER TRANSPARENT BLUE es A INNER CONE SHARPLY OUTLINED WITH BRIGHT LIGHT BLUE A j FLAME RETENTION INNER CONE _ y THERMOCOUPLE PARTIALLY LIFTED FROM BURNER u 7 Figure 8 Pilot Burner Flame Continuous Ignition System Honeywell Q327 Pilot Figure 10 1 Inch Main Burner Flame E Schedule Inspection by Qualified Service Agency Annual or at Beginning of Heating Season For continued safe operation a qualified service agency must provide a more detailed inspection of burners heat exchanger and vent system and provide maintenance as specified in Installation Operating and Service Instructions INCANDESCENT OUTER MANTLE BLUE WITH OCCASIONAL ORANGE FLASHING OUTER CONE DARKER TRANSPARENT BLUE INNER CONE RE SHARPLY DUTLINED WITH CENTER BRIGHT LIGHT BLUE
2. FLAME COMBINATION IGNITION PARTIALLY LIFTED FROM BURNER ELECTRODE SENSING Figure 11 40mm Main Burner Flame GROUND LEAD WHEN REQ D 1 GROUND STRAP FIBERGLASS SLEEVE PILOT TUBING IGNITER SENSOR LEAD BLUE Figure 9 Pilot Burner Flame Intermittent Ignition System EI Honeywell Q3481 Pilot NOTICE This boiler contains controls which may cause the boiler to shut down and not restart without service If damage due to frozen pipes is a possibility the heating system should not be left unattended in cold weather or appropriate safeguards and alarms should be installed on the heating system to prevent damage if the boiler is inoperative All Independence Series Repair Parts may be obtained through your local U S Boiler wholesale distributor Should you require assistance in locating a U S Boiler distributor in your area or have questions regarding the availability of U S Boiler products or repair parts please contact U S Boiler Company Customer Service at 717 481 8400 or Fax 717 481 8408 SERVICE RECORD DATE SERVICE PERFORMED 10 DATE SERVICE RECORD SERVICE PERFORMED
3. b a constant burning pilot burner to provide the ignition source for main burners c a thermocouple to sense pilot burner flame and cause combination gas valve to turn off main burner and pilot burner gas flow should pilot burner flame extinguish B TOP PANELS REAR PANEL Instructions to place boiler in operation and to turn off boiler are shown on the Lighting or Operating Instruction label posted on the inside of the front removable door See Figure 3 for front door removal instructions The Lighting Operating Instructions are also shown in Figures 4 5 and 6 The boiler model number is printed on the rating label see Figure 1 STEP 1 Up LIGHTING OR OPERATING INSTRUCTIONS FRONT REMOVABLE PANEL SUE FORWARD STEP 3 DOWN LOWER FRONT TIE BAR SIDE VIEW Figure 3 Jacket Front Panel Removal FOR YOUR SAFETY READ BEFORE OPERATING POUR VOTRE SECURITE LISEZ AVANT DE METTRE EN MARCHE WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risque de d clencher un incendie ou une explosion entrainant des dommages des blessures ou la mort A This appliance is equipped with an ignition device which automatically lights the bumer Do not try to light the burner by hand BEFORE OPERATI
4. timent Appelez imm diatement votre foumisseur de gaz depuis voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies C Ne poussez ou toumez la manette d admission du gaz qu la main ne jamais utiliser d outil Si la manette reste coincee ne pas tenter de la r parer appelez un technicien qualifi Le fait de forcer la manette ou de la r parer peut d clencher une explosion ou un incendie D N utilisez pas cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau OPERATING INSTRUCTIONS NSTRUCTIONS DE FONCTIONNEMENT STOP Read safety information above to the left on this label Set the thermostat to lowest setting Turn off all electric power to the appliance This appliance is equipped with an ignition device which automatically lights the bumer Do not try to light the burner by hand Remove front door Locate the gas control valve at the end of the gas supply pipe going into the boiler The gas control is the brown or blue plastic knob located on top of the gas control valve Rotate gas control knob clockwise amp from ON position to OFF Make sure know rests against stop Wait five 5 minutes to clear out any gas Then smell for gas including near the fl
5. A la position ON Replacez la porte de devant Mettez l appareil sous tension R glez le thermostat la temp rature d sir e 1 R glez le thermostat la temp rature la plus basse 2 Coupez l alimentation lectrique de l appareil s il faut proc der l entretien 3 Enlever la porte de devant 4 Pousser l g rement le bouton de commande de gaz at tourner sens horaire sur OFF Ne forcez pas 5 Remplacer le porte de devant 104627 01 Figure 5 Lighting Instructions Continuous Ignition System 7000 ERHC Gas Valve I FOR YOUR SAFETY READ BEFORE OPERATING POUR VOTRE SECURITE LISEZ AVANT DE METTRE EN EN MARCHE A B EURPA oa 10 PAD AVERTISSEMENT entrainant des dommages des blessures ou la mort WARNING 1 you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risque de d clencher un incendie ou une explosion This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric swi
6. and VR8304 except Model IN12 Gas Valves MI FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SECURITE LISEZ AVANT D ALLUMER JM 3 4 5 B AVERTISSEMENT entrainant des dommages des blessures ou la mort WARNING if you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risque de d clencher un incendie ou une explosion A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified
7. de ON position OFF position Tourner le bouton de commande de gaz sur le deux robinets de gaz sens horaire de ON position OFF position Attendre cinq 5 minutes pour laisser chapper tout le gaz Reniflez tout autour de l appareil y compris pr s du plancher pour d celer une odeur de gaz Si vous sentez une odeur de gaz ARR TEZ Passez l tape B des instructions de s curit sur la portion sup rieure de cette tiquite S il n y a pas d odeur de gaz passez l tape suivante Tourner le bouton de commande de gaz sur les duex robinets de gaz sens antihoraire AN de OFF position ON position Ne Forcez pas Tourner la manivelle sur manuel robinet sens antihoraire AN de OFF position ON position Ne Forcez pas Replacez la porte de devant Mettez l appareil sous tension R glez le thermostat la temp rature d sir e Si l appareil ne se met pas en marche suivez les instructions intitul es Comment couper l admission de gaz de l appareil et appelez un technicien qualifi ou le fournisseur de gaz A i Y VANNES DE R GULATION GAZ ROBINET D ARR T LA CALA DEL GAS OFF BEE To TURN OFF GAS TO APPLIANCE COMMENT COUPER L ADMISSION DE GAZ DE L APPAREIL MN R glez le thermostat la temp rature la plus basse Coupez l alimentation lectrique de l appareil s il faut proc der l entretien Enlever la porte de devant Tourner la poign
8. pour d celer une odeur de gaz ARRETEZ Passez l tape B des instructions de s c rit sur la portion sup rieure a gauche cette tiquette S il n y a pas d odeur de gaz passez l tape suivante 9 Faites pivoter gas contr le bouton clockwisefrom la position ON OFF Assurez vous que pommeau repose contre stop Ne forcez pas 10 Remplacer la porte de devant 11 Allumer toute l nergie lectrique au appareil 12 R glez le thermostat la temp rature d sir e 13 Si l appareil ne se met pas en marche suivez les instructions intitul es Comment couperl admission de gaz de l appareil et appelez un technicien qualifi ou le fournisseur de gaz TO TURN OFF GAS TO APPLIANCE COMMENT COUPER L ADMISSION DE GAZ Set the thermostat to lowest setting Turn off all electric power to the appliance if service is to be performed Remove front door Rotate gas control knob clockwise 4 from ON position to OFF Make sure knob rests against stop Replace front door Remplacer le porte de devant DE L APPAREIL Regler le thermostat au plus bas regle Coupez l alimentation lectrique de l appareil si le service devrait tre ex cut Enlever la porte de devant Tourner le gaz regle le bouton dans le sens des aiguilles d une montre a partir 7 de position a de Assurer que le se repose contre arete 103028 02 Figure 4 Operating Instructions Intermittent Ignition System VR8204
9. voisin Suivez instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies C Ne poussez ou tournez la manette d admission du gaz qu la main ne jamais utiliser d outil Si la manette reste coinc e ne tentez pas de la r parer appelez un technicien qualifi Le fait de forcer la manette ou de la r parer peut d clencher une explosion ou un incendie D N utilisez pas cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau B O LIGHTING INSTRUCTIONS INSTRUCTIONS D ALLUMAGE M 1 ARR TEZ Lisez les instructions de s curit sur la portion sup rieure de cette tiquette R glez le thermostat la temp rature la plus basse Coupez l alimentation lectrique de l appareil Enlevez la porte de devant Localisez la valve du controle du Gaz a la fin du INDICATEUR DE POSITION depart de la pipe de la proovision du gaz dans l appareil Le bouton plastique brun ou bleu localise sur la valve du controle du gaz Voyez le diagramme LA CALA DEL GAS lt BOUTON DE COMMANDE DE GAZ MONTR EN POSITION OFF Pousser l g rement le bouton de commande de gaz at tourner sens horaire TK sur OFF NOTE Le bouton ne peut pas tre tourn PILOTE sur OFF moins que le bouton est l g rement
10. vous ne pouvez rejoindre le fournisseur de gaz appelezle service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels WARNING CAUTION Indicates a potentially hazardous situation Indicates a potentially hazardous situation which if not avoided could result in death which if not avoided may result in moderate or serious injury or substantial property damage minor injury or property damage Important Product Safety Information Refractory Ceramic Fiber Product Warning The Repair Parts list designates parts that contain refractory ceramic fibers RCF RCF has been classified as a possible human carcinogen When exposed to temperatures about 1805 F such as during direct flame contact RCF changes into crystalline silica a known carcinogen When disturbed as a result of servicing or repair these substances become airborne and if inhaled may be hazardous to your health AVOID Breathing Fiber Particulates and Dust Precautionary Measures Do not remove or replace RCF parts or attempt any service or repair work involving RCF without wearing the following protective gear 1 A National Institute for Occupational Safety and Health NIOSH approved respirator 2 Long sleeved loose fitting clothing 3 Gl
11. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water A General This boiler is equipped with controls for 2 Low Water Cutoff A device which automatically proper operation All controls must be in proper interrupts boiler operation when the surface of the working order Contact a qualified service agency boiler water falls to the lowest permissible operating to provide annual maintenance as specified in the level See Figure 1 The lowest permissible Installation Operating and Service Instructions operating level is indicated on a plate adjacent to the gauge glass The low water cutoff automatically WARNING resets when water returns to its normal level Boiler operation resumes with a call for heat Service on this boiler should be undertaken only 3 Blocked Vent Switch See Figure 7 A device by trained and skilled personnel from a qualified which automatically interrupts boiler operation service agency when excessive vent system blockage occurs Do not attempt to place boiler in operation if control was activated to interrupt boiler operation Contact a qualified service agency CAUTION Do not reset Blocked Vent Switch unless a 1 Limit A device which automatically interrupts boiler operation when the steam pressure exceeds the set point See Figure 1 Maximum allowable pressure is 15 psi Steam pressure can be read on the
12. NG smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or tum the gas control knob Never use tools If the knob will not turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water A Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse Ne tentez pas d allumer la veilleuse manuellement B AVANT DE FAIRE FONCTIONNER reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez pr s du plancher car certains gaz sont plus lourds que l air et peuvent s accumuler au niveau du sol QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur ne pas vous servir des t l phones se trouvant dans le b
13. Pressure Gauge qualified service agency has determined and corrected the cause of any blockage in the vent system or chimney _ VENT DAMPER A gt DRAFT HOOD FRONT DOOR REMOVAL yr INSTRUCTION PLATE 4 y RATING LABEL IGNITION MODULE PRESSURE GAUGE p FRONT REMOVABLE gt GAS LV DOOR BAG VALVE EE Y GAUGE Loa SLASS PO GLASS Me GL PT Fa Ber LIGHTING OPERATING a Z INSTRUCTIONS MOUNTED a x ON INSIDE OF FRONT Aa REMOVABLE DOOR WATER F CUTOFF L D G TC CAT SEF Zr 4 gt gt Pr RS er Figure 1 Control Locations OBSERVATION 4 Flame Rollout Switch See Figure 2 A device which automatically interrupts boiler operation when flames or excessive heat are present in the vestibule The control is a single use device Do not attempt to place boiler in operation if control was activated to interrupt boiler operation Contact a qualified service agency FLAME ROLLOUT SWITCH Figure 2 Flame Rollout Switch 5 Intermittent Ignition System See Figure 1 The Electronic Ignition EI System consists of a an ignition module to initiate monitor and stop burner operation b acombination gas valve to regulate gas flow to burners c apilot burner to provide the ignition source for main burners 6 Continuous Ignition System Standing Pilot See Figure 1 The Continuous Ignition System consists of a acombination gas valve to regulate gas flow to burners
14. US SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez a aucun interrupteur ne pas vous servir des t l phones se trouvant dans le b timent Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies C Ne poussez ou tournez la manette d admission du gaz qu la main ne jamais utiliser d outil Si la manette reste coinc e ne tentez pas de la r parer appelez un technicien qualifi Le fait de forcer la manette ou de la r parer peut d clencher une explosion ou un incendie D N utilisez pas cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualif et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau ARR TEZ Lisez les instructions de s curit sur la portion sup rieure de cette tiquette R glez le thermostat la temp rature la plus basse Coupez l alimentation lectrique de l appareil Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse Ne tentez pas d allumer la veilleuse manuellement Enlevez la porte de devant Placer le robinet d arr t et les deux valves de contr le de gaz la fin de le tuyau d alimentation de gaz entrant dans la chaudi re Tourner la poign e manuelle robinet sens horaire
15. USER S INFORMATION MANUAL INDEPENDENCE GAS FIRED BOILER WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 103539 02 8 13 AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entreposer ni utiliser d essence nid autres vapeurs ou liquides inflam mables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ e Ne pas tenter d allumer d appareils e Ne touchez aucun interrupteur Ne pas vous servir des t l phones dans le b timent o vous vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur e Si
16. e manuelle robinet sens horaire de ON position OFF position Tourner le bouton de commande de gaz sur le deux robinets de gaz sens horaire de ON position OFF position Replacez la porte de devant 1 2 3 4 104628 01 Figure 6 Operating Instructions Intermittent Ignition System VR8304 Gas Valves Model IN12 Only User Maintenance WARNING Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency Inspections should be performed at intervals specified in Installation Operating and Service Instructions and this manual Maintain manuals in a legible condition Keep boiler area clear and free of combustible materials gasoline and other flammable vapors and liquids Do not place any obstructions in boiler room that will hinder flow of combustion and ventilation air A General Housekeeping Continuous Collapsed vent pipe 1 Keep boiler area clear and free of combustible Disconnected or loose joints materials and obstructions to the free flow of combustion and ventilation air to the boiler Sags in horizontal runs Corrosion or other deterioration 2 Do not store or use gasoline or other flammable vapors or liquids in the vicinity of the boiler or any other appliance Broken or loose supports Blocked vent switch not attached to draft hood De ee 3 Do not store or use sources of hydrocarbons in the D Inspect Pilot and Main Burne
17. enforc Ne forcez pas Attendre cinq 5 minutes pour laisser chapper tout le gaz Reniflez tout autour de l appareil y compris pr s du plancher pour d celer une odeur de gaz Si vous sentez une odeur de gaz ARR TEZ Passez l tape B des instructions de s curit sur la portion sup rieure de cette tiquitte S il n y a pas d odeur de gaz passez l tape suivante D posez le panneau d acc s de br leur ue Veilleuse Trouver le pilote en suivant le tube en aluminium de la soupape de Thermocouple commande pour le pilote situ entre l acier br leurs tubulaires 10 Tournez bouton de contr le de gaz dans le sens antihoraire PT la position PILOTE Bouton de commande compl tement maintenez Imm diatement allumer la veilleuse avec un match de football Continuez appuyer sur le bouton de commande pour une 1 minute environ apr s que le pilote est allum Poign e de d brayage et il sautera vers le haut Pilote doit rester allum Si elle s teint R p tez les tapes 6 11 Si le bouton ne se soul ve pas de lui m me lorsqu on le rel che arr tez et appelez imm diatement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fournisseur de gaz Replacez le panneau d acc s de br leur Tournez bouton de de gaz dans le sens antihoraire
18. ety information above on this label If you don t smell gas go to the next step Rotate gas control knob on BOTH gas valves counterclockwise AN from OFF position to ON position Do Not Force AON O 11 Rotate handle on manual shut off valve counterclockwise AN from 11 OFF position to ON position Do Not Force 12 Replace front door 12 13 Turn on all electric power to the appliance 13 14 Set thermostat to desired setting 14 15 If the appliance will not operate follow the instructions To Turn Off Gas 15 To Appliance and call your service technician or gas supplier GAS CONTROL IM VALVES A MANUAL SP SHUT OFF VALVE SE J GAS INLET N on j orr x M Fa Set the thermostat to lowest setting Turn off all electric power to the appliance if service is to be performed Remove front door Rotate handle on manual shut off valve clockwise from ON position to OFF position Rotate gas control knob on BOTH gas valves clockwise A from ON position to OFF position Replace front door A Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse Ne tentez pas d allumer la veilleuse manuellement B AVANT DE FAIRE FONCTIONNER reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez pr s du plancher car certains gaz sont plus lourds que l air et peuvent s accumuler au niveau du sol QUE FAIRE SI VO
19. k up Pilot should remain lit If it goes out 11 repeat steps 6 11 If knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn gas control knob to OFF and call your service technician or gas supplier 12 Replace burner access panel 13 Turn gas control knob counterclockwise TN to ON position 14 Replace front door 12 15 Turn on all electrical power to the appliance 13 16 Set thermostat to desired setting 14 15 16 MI To TURN OFF GAS TO APPLIANCE COMMENT COUPER L ADMISSION DE GAZ DE L APPAREIL MN 1 Set the thermostat to lowest setting 2 Turn off all electric power to the appliance if service is to be performed Remove front door Push in gas control knob slightly and turn clockwise A to OFF Do not force Replace front door A Cet appareil est muni d une veilleuse qui doit tre allum e manuellement Respectez les instructions ci dessous la lettre Avant d allumer la veilleuse reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez pr s du plancher car certains gaz sont plus lourds que l air et peuvent s accumler au niveau du sol QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur ne pas vous servir des t l phones se trouvant dans le b timent Appelez imm diatement votre fournisseur de gaz depuis un
20. oor If you smell gas STOP Follow B in the safety information above to the left on this label If you don t smell gas go to the next step Rotate gas control knob counterclockwise from OFF to ON Make sure knob rest against stop Do not force 10 Replace front door 11 Turn on all electric power to the appliance 12 Set the thermostat to the desired setting 13 If the appliance will not operate follow the instructions To Tum Off Gas To Appliance and call your service technician or gas supplier GAS CONTROL KNOB LA PERILLA DEL CONTROL DEL GAS POSITION INDICATOR POSICIONE INDICADOR 1 ARRETEZ Lisez les instructions de s cOrit sur la portion sup rieure a gauche cette tiquette R glez le thermostat a la temp rature la plus basse Coupez l alimentation lectrique de l appareil Cet appareil est quip de l dispositif d allumage qui automobile allume maticallyle br leur Ne pas essayer d allumer le br leur pr s main Enlevez la porte de devant Localisez la valve du controle du Gaz a la fin du depart de la pipe de la proovision du gaz dans l appareil Le bouton plastique brun ou bleu localise sur la valve du controle du gaz Voyez le diagramme Faites pivoter le bouton de contr le du gaz dans le sens inverse A des aiguilles d une montre de OFF pour ON Attendre cinq 5 minutes pour laisser chapper tout le gaz Reniflez tout autour de l appareil y compris pr s du plancher
21. oves 4 Eye Protection Take steps to assure adequate ventilation Wash all exposed body areas gently with soap and water after contact Wash work clothes separately from other laundry and rinse washing machine after use to avoid contaminating other clothes Discard used RCF components by sealing in an airtight plastic bag RCF and crystalline silica are not classified as hazardous wastes in the United States and Canada First Aid Procedures If contact with eyes Flush with water for at least 15 minutes Seek immediate medical attention if irritation persists If contact with skin Wash affected area gently with soap and water Seek immediate medical attention if irritation persists If breathing difficulty develops Leave the area and move to a location with clean fresh air Seek immediate medical attention if breathing difficulties persist Ingestion Do not induce vomiting Drink plenty of water Seek immediate medical attention Basic Operation CAUTION Should overheating occur or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a location external to the appliance En cas de surchauffe ou si l admission de gaz ne peut tre coup e ne pas couper ni d brancher l alimentation lectrique de la pompe Fermer plut t le robinet d admission de gaz l ext rieur de l appareil Do not use this boiler if any part has been under water
22. r Flame Monthly vicinity of the boiler Sources of hydrocarbons 1 Adjust thermostat to lowest setting include bleaches cleaners chemicals sprays paint 2 Remove front removable panel See Figure 3 removers fabric softeners cat litter and refrigerants 3 Locate Pilot Observation Port See Figure 2 B Flush Low Water Cutoff Weekly or more 4 Check pilot burner flame frequently if needed Applicable to McDonnell a Intermittent Ignition EI see Figure 9 The amp Miller 67 float low water cutoff only Follow pilot burner produces three 3 flames The instructions on Blow Down Card affixed to Jacket center flame should be steady medium hard blue enveloping 3 8 to Y inch of sensing probe If flames are yellow and lazy follow instructions Inspect Vent System Monthly See Figure TO TURN OFF GAS TO APPLIANCE 7 Follow instructions TO TURN OFF GAS TO see Figure 4 for Models IN3I through IN11 or APPLIANCE see Figure 4 5 or 6 and contact Figure 6 for Model IN12 and contact a qualified a qualified service agency if any of the following service agency conditions are found b Continuous Ignition Standing Pilot Models IN10 IN12 See Figure 8 Pilot burner E UNED CHIMNEY produces three 3 flames The center flame hi should be steady medium hard blue enveloping 3 8 to inch of thermocouple If flames are yellow and lazy follow instructions TO TURN OFF GAS TO APPLIANCE see Figure 5 and contact a qualified service agency
23. service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above on this label POSITION 2 Set thermostat to lowest setting INDICATOR 2 3 Turn off all electrical power to the appliance ES 3 4 Remove front door on OFF lt q 4 5 Locate gas control valve at end of gas Seror 5 supply pipe going into boiler Gas GAS control knob is the gray or brown INLET GAS CONTROL KNOB plastic knob located on top of gas control valve OFF POSITION 6 Push in gas control knob slightly and turn clockwise TK to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 6 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in safety information above on this label If you do not smell gas go to next step NOTE Vent damper must 7 be open during this five 5 minute waiting period Pilot Burner 8 Remove burner access panel hermocouple 9 Find pilot by following aluminum tube from gas control valve to pilot located 8 between steel tube burners 9 10 Turn gas control knob counterclockwise AN to PILOT position 11 Push in control knob all the way and hold in Immediately light pilot with match Continue to hold control knob for about one 1 minute after pilot is lit Release knob and it will pop bac
24. tch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water MO OPERATING INSTRUCTIONS INSTRUCTIONS DE MISE EN MARCHE STOP Read safety information above on this label Set the thermostat to lowest setting Turn off all electric power to the appliance This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand Remove front door Locate manual shut off valve and both gas control valves at end of gas supply pipe going into boiler Rotate handle on manual shut off valve clockwise from ON position to OFF position Rotate gas control knob on BOTH gas valves clockwise from ON position to OFF position Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the saf