1. BATTERY LEVEL MEASUREMENT HOLD UNITS THERMOMETER DIGITAL cea READING MAIN MENU Single Axis Mode Operation Place the digital level on the surface to be measured Please ensure the contact surfaces of the device and measuring plane are clean and free from dust particles The green arrow sign on display indicates the higher side User may freeze the screen by pressing the HOLD button The icon 2 pops up to indicate the screen is paused To resume operation press the hold button once 2015 DIGIPAS USA LLC All Rights Reserved Dual Axis Mode Interface Dual Axis Mode Display Screen and Button Function _ _ HORIZONTAL X AXIS BATTERY LEVEL A DIGITAL READING N MEASUREMENT UNITS gt MEASUREMENT y UNITS THERMOMETER IN NS i VERTICAL Y AXIS MAIN MENU Digi Pas __ DIGITAL READING HOLD Dual Axis Mode Operation 77 ie N Place the digital level on the surface to be measured e R O Please ensure the contact surfaces of the device and measuring plane are clean and free from dust particles b e Digi Pas ___ The Target Ball or Bull Eye move towards the measured position similar to traditional Bubble vials The green arrow sign on display indicates the higher side of plane Once the measurement stabilizes the Target Ball or Bull Eye blinks Digi Pas _ 2015 DIGIPAS USA LLC All Rights Reserved Main M
2. Alternate Zero Sync Menu Angle Meter Vibro Meter Setting Menu CHAPTER 5 STORAGE AND CLEANING CHAPTER 6 WARRANTY APPENDIX USER CALIBRATION 2015 DIGIPAS USA LLC All Rights Reserved CHAPTER 1 DEVICE OVERVIEW Technical Specification DWL8500X Y Measurement Range O to 14400 arcsec Single Axis Mode 0 0000 to 4 0000 Measurement Range 0 to 7200 arcsec 2 Axis Mode 0 0000 to 2 0000 Resolution l arcsec lt 5um M 1 arcsec at 0 1080 arcsec Accuracy 3 arcsec at other angles Repeatability 1 arcsec lt 5um M Display Colour TFT LCD Power Supply 4 x AAA 1 5V Batteries USB Power source Material PC ABS Cast Iron Titanium USB 2 0 Cable S 5 metre Bluetooth lt 30 metre Connectivity PC SYNC Software Professional Edition Included Operating Temperature te OE P 8 P Calibrated for the entire temperature range Storage Temperature 20 C to 60 C Dimension mm 188 x 62 x 37 Nett Weight Approx 1150 gram Specifications are subject to change without notice Note Product performance to specification are comply with accredited Calibration amp Test Providers in USA Japan UK and Germany to conform with NIST JIS UKAS amp DIN under the International Laboratory Accreditation Cooperation ILAC and American Association for Laboratory Accreditation A2LA For more information please visit www digipas com 2015 DIGIPAS USA LLC All Rights Reserved
3. Device Overview Battery Compartment of 4 x AAA size 1 5V batteries Observe the polarity of the batteries indicated on the top of the battery cover USB Port USB power supply PC Synchronization Firmware update ON OFF Power On Off Escape from Mode function Scroll up LCD Colour graphic digital display CAL Activate calibration mode HOLD Freeze display value Buzzer sound alert Scroll right MODE Change the function and display mode UNIT Change the unit arcsec mm M of the Enter the function measurement Scroll down Scroll left FRONT VIEW Side screw holes For mounting purpose Using of three contact points screw on measuring plane surface Cast Iron Base BACK VIEW 2015 DIGIPAS USA LLC All Rights Reserved List of items included in DWL 8500XY product package 1 DWL 8500XY Ultra Precision Digital Level E l with Vibrometer amp Bluetooth function Certificate of Calibration 1 AAA batteries USB 2 0 cable 3 Meters l pe PC Sync PRO Software amp security dongle l pe M5 Button head screws 2015 DIGIPAS USA LLC All Rights Reserved CHAPTER 2 SETTING UP Operation Procedure 1 Insert 4 pieces of AAA batteries into the battery compartment and press ON OFF button Alternatively insert USB power source to the USB Port to power up the device Take note that the device performance might be affected when poorly regulated USB power source is
4. To set automatic dim according to user defined time period To turn on off the device buzzer Display Brightness To set LCD brightness according to user defined level 2015 DIGIPAS USA LLC All Rights Reserved CHAPTER 5 STORAGE AND CLEANING Storage Keep the device in the equipment box and maintain the storage temperature within 20 C to 60 C or 4 F to 140 F When the device is not in used the batteries are to be removed from the device Cleaning 1 Keep the device dry and clean Remove any moisture or dirt with a soft dry cloth before measurement to obtain the maximum accuracy Do not use harsh chemicals strong detergents or cleaning solvent to clean the device 2 Do not submerge device in liquid while cleaning 2015 DIGIPAS USA LLC All Rights Reserved CHAPTER 6 WARRANTY Digi Pas 2 Axis Ultra Precision Digital level is warranted to the original purchaser to be free from defects in workmanship and material JSB Tech will at its option repair or replace any defective part which may malfunction under normal and proper use within a period of 2 two years from the date of purchase The forgoing warranty shall not apply to defects resulting from misuse abuse assignment or transfer by the Buyer Buyer supplied software or interfacing unauthorized modification or operation outside of environment specifications for the product JSB Tech does not warrant that the operation of instrument software or firmware w
5. BACK TO PREVIOUS MENU i I 2 Magnitude AUTO SET SPEED HOLD SCALE g Time SELECTION SELECTION on Second ZOOM MENU ZOOM MENU ZOOM MENU TO SCALE MAGNITUDE amp TIME S ZOOM IN ZOOM OUT SPEED OF DATA ACQUISITION Vibro Meter Setting Vibro Meter Place the device on the surface to be measured A Press Auto Set button to set the line graph to the centre of display agnitude M Please ensure the contact surfaces of the device and measuring plane are clean and free from dust particles Vibro Meter When the device detects the vibration the relative magnitude g is shown on the graph Y Time s Magnitude g Vibro Meter To change the scale and speed of the line graph press the scale selection button or the speed selection button accordingly Magnitude mg 2015 DIGIPAS USA LLC All Rights Reserved To Setting Menu Display Screen and Button Function p Setting i C Units D Current Device Location E Country Sent p C AutoOff gt SELECTION SELECTION Auto Dim Buzzers D ONIN Display Brightness D SETTING PARAMETERS Units To change the measuring unit arcsec mm M To change the location of the device when you use it in a Current Device Location different country or city Select the nearest option when your location is not available in the default list AutoOfft To set automatic power off according to user defined time period
6. Digi Pas Innovation amp Technology Driven USER MANUAL 2 Axis Ultra Precision Digital Level Model DWL8500X Y www digipas com REVISION 2 20 Note Contents in this instruction manual is continuously updated please check Digi Pas website for latest version INTELLECTUAL PROPERTY This manual contains propriety information which is protected by copyrights All rights are reserved No part of this manual may be photocopied reproduced redistributed or translated to another language without prior written consent of JSB TECH Company The information in this manual was correct at the time of printing stored in CD or uploaded in the Company website However JSB TECH will continue to improve products and reserves the rights to change specification and maintenance procedures at any time without prior notice Digi Pas Products were manufactured under ISO9001 amp ISO14001 standards tested to comply by the followings certification bodies ISO9001 1S014001 OHSAS 18001 CE FE Ros 2015 DIGIPAS USA LLC All Rights Reserved Digi Pas logo is registered trademarks of JSB TECH Pte Ltd CONTENTS CHAPTER 1 DEVICE OVERVIEW Technical Specification Overview List of Items CHAPTER 2 SETTING UP Operating Procedure Mounting Device on Fixture CHAPTER 3 USER INTERFACE Single Axis Mode Interface Dual Axis Mode Interface Main Menu Icon Functions CHAPTER 4 FEATURES AND SETTING Absolute Level
7. G MOVE TO LEFT MOVE TO RIGHT Cursor SELECT ENTER SYNC via Current Status Bluetooth SYNC Menu Setting Synchronization _ Settin The status bar indicates current selected mode as USB To g change to Bluetooth mode scroll the right button and then USB Bluetooth press MODE button Bluetooth Sire Reboot the device by turning off the device and then turn on the device again to activate the new setting Once Bluetooth mode 1s activated the icon will display on the single and dual axis mode screen display 2015 DIGIPAS USA LLC All Rights Reserved p 9 Angle Meter Screen Display and Button Function BATTERY Angle Meter S LEVEL BACK TO MAIN MENU Time MEASUREMNT Second UNIT HOLD SELECT ENTER HORIZONTAL DIGITAL READING Angle Meter Setting Angle Meter Place the digital level on the surface to be measured Please ensure the contact surfaces of the device and measuring plane are clean and free from dust particles An gle Degree The Angle Meter displays real time continuous angle measurements in line graph Angle Degree User may freeze the screen by pressing the HOLD button The icon pops up to indicate the screen is paused To resume operation press the hold button once t ts Angle Degree 2015 DIGIPAS USA LLC All Rights Reserved Vibro Meter Screen Display and Button Function ERE BATTERY Vibro Meter TSA lt Evel
8. ations of liability set forth above shall apply to the maximum extent permitted under applicable law Distributed by Manufactured by JSB TECH PTE LTD Email info digipas com www digipas com JIM 2 08501 99 001 2015 DIGIPAS USA LLC All Rights Reserved APPENDIX USER CALIBRATION Calibration Instruments Granite Table Grade AA Levelled to lt 0 5 arcsec Granite Table Calibration Procedures Ensure the DWL8S500XY device is in power OFF condition Press and hold the CAL button by using a small Professional Digital Level pin and simultaneously press the ON OFF button The ana a LCD screen displays Calibration 1 Digi Pas 1 Place the device to Position 1 Press the MODE button once and wait until the countdown reach 0 the LCD screen displays Calibration 2 Position 1 2 Turn the device 180 to Position 2 Press the MODE button again to start the calibration at Position 2 and wait until the countdown reach 0 the LCD screen displays Calibration 3 Position 2 2015 DIGIPAS USA LLC All Rights Reserved 3 Place the device to Position 3 Press the MODE button once and wait until the countdown reach 0 the LCD screen display Calibration 4 Position 3 4 Turn the device 180 to Position 4 Press the MODE button again and wait until the countdown reach 0 the LCD screen will switch to measuring mode once calibration is compl
9. enu Icon Screen Display and Button Function TITLES EXIT MAIN MENU ICONS SCROLL LEFT SCROLL RIGHT SELECT ENTER ABSOLUTE LEVEL SETTING Enable user to ensure each measurement reading is in accordance to maximum device accuracy specified ALTERNATE ZERO SETTING Enable user to measure relative angles at a common plane with respect to a reference angle Set any angle to 0 as a reference SYNC MENU Enables user to select the connectivity USB Bluetooth with a computer installed with PC Sync Software 2015 DIGIPAS USA LLC All Rights Reserved ANGLE METER Enables user to obtain real time continuous angle measurements displayed in line graph VIBRO METER Enables user to obtain real time continuous vibration measurements displayed in line graph SETTING MENU Enable user to modify various parameters of the device HELP MENU Enable user to have a quick and easy reference on Device s button configuration 2015 DIGIPAS USA LLC All Rights Reserved CHAPTER 4 FEATURES AND SETTING DS iz Absolute Level Screen Display and Button Function BACK TO MAIN MENU Absolute Level Setting INSTRUCTION INDICATOR lt LOADING BAR SELECT ENTER Absolute Level Setting T Place the device on the surface to be measured Press MODE Absolute Level button to start the measurement and wait until the loading bar Setting is full A N Please ensure the contact surfaces
10. eted Position 4 Precaution To achieve maximum accuracy the device must be held firmly on to jig during calibration process Any movement on countdown during each calibration procedure would affect device accuracy 2015 DIGIPAS USA LLC All Rights Reserved
11. ill be uninterrupted or error free The exclusive remedy under any and all warrants and guarantees expressed herein and we shall not be liable for damages from loss or delay of equipment uses consequential or incidental damage No other Warranty is expressed or implied JSB Tech specifically disclaims the implied warranties of merchantability and fitness for a particular purpose Limitation of Liability In no event shall DIGIPAS USA LLC hereinafter the Company be liable to you or any third party for any indirect special incidental exemplary or consequential damages of any kind resulting from any breach of warranty or from the performance or use of the product This includes without limitation property damage loss of value of the product or any third party products that are used with the product or loss of use of the product or any third party products that are used with the product even if the Company has been advised of the possibility of such loss or damages The Company s total cumulative liability arising from or related to the product whether in contract tort including negligence or otherwise shall not exceed the amount actually paid by you for the product Some states and or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you If any limitation of liability shall be deemed invalid by any applicable law then the limit
12. of the device and measuring plane are clean and free from dust particles Note The device is able to auto detect its position is single axis position or dual axis Absolute Level Turn the device 180 and press MODE button again to start Setting the measurement When completed the above settings the ap logo is shown to indicate that the device is in the Absolute Level mode 2015 DIGIPAS USA LLC All Rights Reserved a Alternate Zero Screen Display and Button Function BACK TO MAIN MENU Alternate Zero Setting INSTRUCTION INDICATOR MEASUREMNT UNIT HOLD SELECT ENTER SINGLE OR Dual AXIS INDICATOR Alternate Zero Setting Place the digital level on the surface to be measured Press Alternate Zero MODE button to set the angle to 0 as a reference Setting Please ensure the contact surfaces of the device and measuring plane are clean and free from dust particles Note The device is able to auto detect its position is single axis position or 2 axis E o The Ex logo is shown to indicate that the device is in l Alternate Zero mode Dig Pas User may freeze the screen by pressing the HOLD button The icon pops up to indicate the screen is paused To resume operation press the hold button once 2015 DIGIPAS USA LLC All Rights Reserved e SYNC Menu Screen Display and Button Function Synchronization BACK TO MAIN MENU Setting USB Bluetooth
13. used Battery 4x AAA size 1 5V batteries Take note on the battery s polarity as indicated on top of the battery cover Initial Setup Default Units USB Port Current Device Location gt Country or select nearest country city 2 Initial Setup screen pops up Press ON OFF button to scroll up or MODE button to scroll down for selecting Default Units or Current Device Location Press UNITS or HOLD button to input the selected option Select the nearest option when your location is not available in the default list Scroll to select Done to continue 3 Allow sufficient time for the device to stabilise during initial power up When the thermometer on the screen turns green the device is ready to use Note For maximum accuracy perform calibration refer to APPENDIX User Calibration or Absolute Level refer to Chapter 4 Absolute Level for more details before measurement Mounting Device On Fixture or Work Piece The two threaded holes are provided for mounting the device onto user defined fixtures machinery P User defined fixture machinery To mount the device onto user s defined fixture or work piece Remove both the set screw M5 then replace with appropriate type of screws specified by user 2015 DIGIPAS USA LLC All Rights Reserved CHAPTER 3 USER INTERFACE single Axis Mode Interface EPN a Sata Professional Digital Level VibroMeter Digi Pas DWL 8500 XI
Download Pdf Manuals
Related Search
Related Contents
Manual Aquecedor Halógeno MA-012Hnovo.indd 2.0 Installing The Caller ID Device 第44回神戸まつり おまつり屋台村出店申し込み案内 D-Link DES-3226L User's Manual らくらくホン ベーシックS 取扱説明書 FOMA F883iS Philips CD4452S Cordless phone answer machine Guide d`administration système du serveur Netra 440 Anleitung Big Outdoor Lama-Deutsch.indd - RC-Toy dreamGEAR 24 Hour Fitness 4 in 1 Fitness Starter Kit for Wii Fit & Wii Fit Plus Copyright © All rights reserved.