Home
FlowMarker II
Contents
1. Fog Generator was especially developed for the visualization and photographic documentation of slow and weak airflows in the fields of science and technology Fog is produced with the world s unique and completely harmless SAFEX theatrical fog fluids The generation of low impulse thermal neutral fog helps to solve even very difficult problems of airflow visualization In areas with a calm airflow even small cavities can be filled with fog This fog as if flowing like water forms a fog lake on the surface where even very weak airflows can be recognized Furthermore new additional system components such as the FM HYDRA TUBE SYSTEM are available which makes it now possible to insert the fog for example via GAFM II 01 12 34 8 hoses or by means of different probes fog screens etc into difficult places or in a special way into air flows machinery etc See for this section G OPTIONAL ACCESSORIES The FlowMarker basic equipment consists of SYSTEM the FlowMarker Device itself COMPONENTS _ one Plug in Battery 12V 2 0Ah 20HR type LC TA122PU one unscrewable Application Tube type AR1 pressurized aerosol can FlowMarker Fog Fluid fogging agent 5 Condensation Absorbing Rings each type KR1 and KR2 two in the application tube one Plastic Tube for removing condensation absorbing ring KR1 alow voltage POWER SUPPLY 12 V 1 A 100 240 V gt 12 VA for charging the battery in
2. battery out of the device every time to prevent the device from starting The two contacts of the battery must also be covered e g with insulating tape etc The battery is correctly positioned in the luggage compartment if it is fully embedded with the naked contacts in the foam inlay with the back of the battery upwards battery back is up if the side inscription is in normal reading position TRANSPORT GAFM II 01 12 34 16 SAFETY INSTRUCTIONS F All SAFEX FOG GENERATORS and its accessories comply with DIN VDE Regulation 0700 part 245 as well with the EC directives 2001 95 EG 2006 95 EG 75 324 EWG and the regulation EG Nr 1272 2008 and therefore meet the legal regula tions of the European Community The FlowMarker fulfils international standards for low voltage operated electric devices The FlowMarker contains no freely accessible hazardous materials and only one heating element with circa 40 W power input The entire power supply takes place exclusively with protective low voltage provided the added mains charging adapter is used which fulfils local safety requirements Please notice 1 The machines are equipped with a safety device If the heating does not work properly the machine will turn in a safe condition 2 Replace fuses only while machine is switched off and the failure has been cleared by an expert Use only proper spare part fuse 5 x 20 mm type see chapter H TECHNICAL DATA on page 21 3 D
3. 80 of the window Do not overfill the tank under any circumstances Pull the valve stem out of the fill opening Put the valve protecting cap onto the can Prevent filling parts from getting dirty f Remove possible fluid remainders from the fill opening with a paper towel FOG FLUID is non toxic and harmless and bears no hazards 34 GAFM II 01 12 battery compartment safety screw INSERTING BATTERY The insert battery is delivered with a partial charge for the initial test of the device We recommend to entirely charge the battery before continuous use see also chapter D MAINTENANCE CARE a place the battery in the device first loosen the battery compartment safety screw see illustration with a screwdriver counter clockwise just one or two turns until the screw head corresponds with the outer surface of the device s housing Stop if there is noticeable resistance do not use force this may damage the battery compartment b Now push the battery into the battery compartment see illustration with contacts first and inscription LONG pointing up until the battery audibly and noticeably clicks into place Now fasten the battery securing screw by turning it clockwise again stop if there is noticeable resistance d This operation is necessary to prevent the battery from falling out By no means let the lead acid battery fall out of the device as it might break and cor
4. B rste oder einem kr ftigen Pinsel zu reinigen auch kann diese Stelle durch warmes Wasser gereinigt werden Alle Geh useteile sind aus Edelstahl Es darf jedoch kein Wasser in das Innere des Ger tes gelangen Selbstverstandlich ist das Bef llsystem des SAFEX FlowMarker mit einem hochwirksamen Filter ausger stet der bei Bedarf auf einfache Weise gewechselt werden kann Ist beim Nachf llen von Nebelfluid mit einer frischen mit ausreichend Druck versehenen Fluiddose zu beobachten dass sich nur sehr langsam oder praktisch kein GAFM II 01 12 34 28 BATTERIE WECHSEL BATTERIE EXTERN LADEN FLUIDF LLUNG UND TANK FILTERWECHSEL 29 34 GAFM II 01 12 NEBELFLUIDDOSE UND FLUIDDRUCK KONDENSAT AUFNAHMERINGE Fluid in den Tank einbringen l sst so kann neben einer leeren oder drucklosen Fluiddose als Ursache der Einf llfilter verstopft sein Der Filterwechsel ist dann wie folgt vorzunehmen 1 Einf ll Filterkartusche siehe Abb links mittels einer M nze durch Linksdrehen aus dem Ger t herausschrauben 2 Wei en Mikroporenfilter 30 my aus der Filterkartusche entnehmen ggf Pinzette verwenden und entsorgen Gleichzeitig auch schwarzen Dichtungs O Ring entfernen 3 Neuen Mikro Filter in vorgesehene Vertiefung ohne Kraftanwendung dr cken und ebenfalls neuen O Ring in Nut einlegen O Ring muss faltenfrei und gleichm ig in der Nut liegen Dabei auf u erste Sauberkeit achten 4 Jet
5. Heizelement mit ca 40 Watt Leistungsaufnahme Die gesamte Stromversorgung findet ausschlie lich mit Schutzkleinspannung statt vorausgesetzt der mitgelieferte vorschriftsm ige CE STECKERTRAFO wird verwendet Dennoch sind die folgenden Hinweise zu beachten 1 Die Ger te sind mit einer Defektschaltung versehen Fehlfunktion der Heizung schaltet sich das Ger t in einen sicheren Betriebszustand 2 Ein Auswechseln von Sicherungen darf nur bei abgeschaltetem Ger t nach Behe bung der Ausl seursache durch einen Fachmann unter Verwendung von geeigne tem Ersatzteil erfolgen Feinsicherung 5 x 20 mm Wert siehe im Abschnitt H TECHNISCHE DATEN S 34 3 Elektrische W rmeger te die durch Sturz besch digt werden konnten d rfen nicht wieder in Betrieb genommen werden da die Sicherheitseinrichtungen auch ohne sichtbare Sch den von au en besch digt sein k nnen In Zweifelsf llen Bat terie aus dem Ger t entnehmen und dieses zur Reparatur einsenden 4 Unsachgem e Reparaturen bzw Ver nderungen der Regeleinrichtungen k nnen zu Gefahren und zur Zerst rung des Ger tes f hren z B auch bei feh lerhaften Netzkabeln und Ladeger ten oder Kurzschluss in der Ladebuchse Repa raturen sollten nur durch autorisierte Werkst tten Hersteller vorgenommen werden 5 In R umen mit Publikumsverkehr sollte das Ger t f r Unbefugte nicht zugriffsbe reit sein Ger t und Zubeh r Fluiddose usw geh ren ebe
6. dabei senkrecht so halten dass das Tankfenster zu sehen ist Ger t jetzt leicht auf die Dose dr cken dabei wird das Nebelfluid aus der Dose das Ger t gedr ckt Wichtig Es d rfen keine Schmutzpartikel in die Bef ll ff nung gelangen d Der Bef llungsvorgang ist im Tankfenster erkennbar Der Tankkolben mit der gelben Markierung bewegt sich zur Ger ter ckseite Der Bef llungsvorgang ist zu beenden wenn die gelbe Markierung 80 des Sichtfensterausschnittes zur ckgelegt hat Tank keinesfalls berf llen e Fillstift wieder aus der Bef ll ffnung herausziehen und Ventil Schutzkappe zur ck auf die Dose setzen Verschmutzung der Bef llungsteile unbedingt ver meiden f Bef ll ffnung ggf mit einem Papiertuch von anhaftenden Fluidresten reinigen SAFEX NEBELFLUID ist ungiftig und ungef hrlich und stellt keine Gefahr dar 23 34 1 01 12 Sicherungs schraube BATTERIE EINSETZEN Die Einschub Batterie ist ebenfalls werkseitig teilgeladen um eine erste Erprobung des Ger tes zu erm glichen Es wird jedoch empfohlen die Batterie zun chst einmal vollst ndig zu laden Siehe dazu Abschnitt D WARTUNG PFLEGE a Zum Einsetzen der Batterie zuerst die Batteriefach Sicherungsschraube siehe Abb rechts mit einem Schraubendreher durch Linksdrehen soweit heraus schrauben bis der Schraubenkopf mit der Au enfl che des Geh uses in etwa fluchtet und ein leichter Widerstand zu sp ren i
7. der Garantiezeit bewirken ein sofortiges Erl schen jeder Gew hrleistung und der Haftung des Herstellers bzw des Vertreibers Ger t daher nicht unautorisiert ffnen keine Geh useschrauben l sen Reparaturen nur durch autorisierte Service Stellen durchf hren lassen Besch digte oder unvorschriftsm ige Ladeger te k nnen zu Zerst rung der Batterie oder zu elektrischem Schlag mit t dlichem Ausgang f hren daher nur gepr fte und geeignete Ladevorrichtungen verwenden Nebel oder Applikationsrohr nicht in K rper ffnungen einbringen G OPTIONALES ZUBEH R Alle SAFEX FlowMarker Gerate der Baureihe II Blaue Aufschrift blauer Nebelknopf sind mit einer Fernsteuer sowie einer Ladebuchse Niederspannungseingangsbuchse ausgestattet Die folgenden FlowMarker FERNSTEUERUNGEN k nnen so angeschlossen werden _FliowMarker Kabelfernsteuerung 10 m einfache jedoch robuste Kabelfernsteuerung mit hochflexiblen d nnem Kabel mit dem durch Knopfdruck der Nebelvorgang aus der Ferne ausgel st werden kann _SAFEX FM Funkfernsteuerung 30 m Reichweite kleine komfortable Funkfernsteuerung bestehend aus Sender und Empf nger Der Empf nger wird mittels VELCRO Klebepunkten abnehmbar am FlowMarker befestigt der Handsender erm glicht es eines oder mehrere Ger te kabellos fernzusteuern Die Fernsteuerung besitzt eine Zulassung f r den gesamten EU Bereich FM HYDRA SCHLAUCHSYSTEM zur flexiblen Leitung
8. des Nebels bestehend aus FM HYDRA SCHLAUCHVORSATZ Schlauch und weiterem Zubeh r siehe separates Informationsblatt FlowMarker Applikationsrohr Verlangerung AR3 75 cm lang Verl ngerung zum Aufstecken auf das Applikationsrohr um in schwierigen Positionen Nebel ausbringen zu k nnen FLOWTRACER 75 cm lang Nebelrechen Verl ngerungsrohr mit Bohrungen zur Erzeugung eines Nebelfadenvorhangs _FliowMarker NETZKABEL 10 m flexibles d nnes Kabel zur dauernden Stromversorgung des FlowMarker mittels des vorhandenen Netz Ladeger ts GA FM II 01 12 34 34 H TECHNISCHE DATEN FLOWMARKER BETRIEBSSPANNUNG STROMAUFNAHME LEISTUNG LADEGERAT INTERNATIONAL ABMESSUNGEN GEWICHT GEWICHT MIT KOFFER UND ZUBEHOR BATTERIE LADEZEIT BATTERIE BETRIEBSZEIT BATTERIE SPARMODUS SCHLAFMODUS GER TE SELBSTABSCHALTUNG AUFHEIZZEIT BETRIEBSSTOFF TANKINHALT FLUIDVERBRAUCH NEBELLEISTUNG FLUIDDOSE 12 Volt DC aus interner Batterie Stromaufnahme 3 4 A im Heizbetrieb Heizleistung 40 W Absicherung intern Sicherung 5 x 20 mm 6 3 Amp mitteltr ge Steckernetzteil Ladeger t f r alle Spannungen weltweit mit Steckadaptern f r EU GB USA Australien CE UL gelistet 100 240 V AC 50 60 Hz 250 mA 18 VA Output 12 V DC 1A 12 VA L nge 210 mm ohne Applikator mit Standard Applikationsrohr 500 mm Breite 90 mm H he mit Griff 135 mm 2 7 kg mit Batt
9. nimmt bei jedem F llvorgang ab Es dauert daher jedes Mal einige Sekunden l nger um den Tank zu bef llen Um die Dose nicht fehlerhaft zu entl ften darf der Bef llvorgang des Ger tes nur mit dem Ventilstift senkrecht nach oben erfolgen eine Bef llung in waagerechter oder anderer Position ist z Z noch nicht m glich F r spezielle Anwendungen kann es erforderlich sein dass nur sehr wenig Nebel erzeugt wird Da die Aussto menge vom Bef llungsgrad des Tanks abh ngig ist kann es daher sinnvoll sein den Tank ggf nur zu einem Drittel oder zur H lfte zu f llen W hrend der Nebelerzeugung entsteht unvermeidlich in den Applikationsrohren ein Nebelfluidniederschlag Geringe Mengen trocknen bei warmer Umgebungsluft nach einiger Zeit wieder weg so wie sich auch ein Nebelfluid Niederschlag z B auf kalten Oberfl chen nach kurzer Zeit r ckstandslos verfl chtigt wenn die Umgebung gut bel ftet wird Bei intensiverem Gebrauch des Ger tes wird jedoch speziell im Applikationsrohr der Niederschlag zunehmen wenn dieses nicht gut von warmer Luft durchstr mt wird Um heraustropfendes Fluid aus dem Rohr und damit Rutschgefahr zu vermeiden m sste das Rohr h ufiger w hrend des Einsatzes abgenommen und ausgewischt werden Einfacher ist jedoch die Verwendung der FM KONDENSAT AUFNAHMERINGE KR 3 und KR 2 die als Zubeh r erh ltlich sind Der gr ere Ring KR2 wird von der Gewindeseite so in das Applikationsrohr eingeschoben
10. the device leads to the immediate loss of any guarantee or liability on the manufacturer s or supplier s side Therefore do not open the device and do not unscrew any of its screws Repairs must be carried out only by authorized service centers Damaged or improper battery chargers may cause damaging of the battery and lethal electric shock Therefore use only checked and suitable charging devices which comply with national regulations Under no circumstances use device any longer if the red battery LED lights up permanently Do not put fog or application tube into orifices of the body G OPTIONAL ACCESSORIES All SAFEX FlowMarker series II blue inscription blue fog button are with a remote and acharging socket low voltage input jack The following FlowMarker REMOTE CONTROLS can be connected FlowMarker CABLE REMOTE CONTROL 10 m simple but robust cable remote control with highly flexible thin cables With a push of a button the fog can be triggered from distance _SAFEX FM RADIO REMOTE CONTROL 30 m operating range small comfortable remote control consisting of transmitter and receiver The receiver will be attached removable at the FlowMarker by means of VELCRO adhesive points the hand held transmitter allows the remote control of one or more devices wirelessly The remote control has a certification for the whole EU area TUBE SYSTEM for flexible ducting of the fog
11. C or in open flames Heat sources like lamps central heating or other closed heating systems or electric machines without red glowing parts or small flames like candles laboratory burner etc bear no hazard and need not to be given attention Use the FlowMarker only in dry condition do not pour water over the device or immerse it in water Any dirtying with aggressive media dust solvent etc may cause serious damage The FlowMarker is not suitable for use in explosive environment It has no EX protection Never use it in close proximity to open containers with inflammable liquids or in saturated areas with fumes of inflammable liquids or gases Due to physical processes longer or improper use will inevitably result in some fog fluid condensing inside the application tube The condensed fluid can easily be wiped off with a paper towel or washed off with water Remove fluid drops or spilled fluid on the ground as viscous fluids create a risk of skidding Fluid absorbent rings are available as accessory They are inserted on both ends of the application tube The larger ring KR2 has to be inserted from the threaded side of the application tube until it fits behind the air inlet holes at the recess It must not cover the air holes The smaller ring KR3 has to be inserted from the muzzle side of the black tube until it has completely slipped in The rings will absorb possible fluid condensation They have to be replaced period
12. SPEZIALEFFEKTE F R B HNE FILM FERNSEHEN A FlowMarker Iii Instruction Manual Gebrauchsanleitung 1 0 FM II 01 12 34 2 Dear SAFEX Customer Sehr geehrter SAFEX Kunde This instruction manual is bilingual you will find the German version in the 2nd part Questions regarding use and maintenance we are pleased to answer by phone or eMail Please read the safety instructions before use Diese Gebrauchsanleitung ist zweisprachig die deutsche Version finden Sie im 2 Teil Fragen zur Anwendung beantworten wir gerne auch per Telefon oder E Mail Die Sicherheitshinweise sollten vor Gebrauch unbedingt gelesen werden DISTRIBUTOR VERTRIEB Tintschl BioEnergie und Str mungstechnik AG Goerdeler Stra e 21 D 91058 Erlangen Tel 49 0 91 31 81 24 97 30 Fax 49 0 91 31 81 24 97 39 e mail best tintschl de MANUFACTURER HERSTELLER G NTHER SCHAIDT SAFEX CHEMIE GMBH D 22869 Schenefeld Blankeneser Chaussee 26 32 Tel 49 0 40 83 92 11 0 Fax 49 0 40 830 14 52 e mail info safex de COPYRIGHT 2001 2012 by GUNTHER SCHAIDT SAFEX CHEMIE GMBH Jeder Nachdruck und jede fototechnische Vervielf ltigung auch ber elektronische Verfahren ist nur mit Zustimmung des Copyright Inhabers zul ssig 34 GA 1 01 12 FLOWMARKER II INSTRUCTION MANUAL This instruction manual the MSDS for the Fog Fluid and other data sheets are available as PDF downloads at
13. ca 2 Minuten kein Nebel entnommen also der blaue Taster nicht erneut bet tigt schaltet sich das Ger t in den Sparmodus Dieser Sparmodus l sst die Verdampfertemperatur etwas absinken erlaubt aber dem Anwender jederzeit wieder den Nebelknopf zu bet tigen wobei dann die Nebelproduktion lediglich mit einigen Sekunden Verz gerung max 6 Sek je nach L nge der Nutzungsunterbrechung startet Wird jedoch auch in diesem Sparmodus kein Nebel erzeugt schaltet sich das Ger t nach weiteren 15 Minuten automatisch in den sog SCHLAFMODUS in dem auch die Heiz funktionen zum Erliegen kommen lediglich ggf eingesteckte Funk oder Kabel Fernsteuerungen werden noch unterst tzt Mit Hilfe dieser oder durch Bet tigung des NEBEL Knopfes am Ger t kann der SAFEX FlowMarker jedoch jederzeit wieder kurzfristig aktiviert aufgeheizt werden Dieser Schlafmodus wird ebenfalls f r weitere 2 Stunden aufrecht erhalten Sollte auch dieser Zeitraum ohne Nebelerzeugung verstreichen schaltet der eingebaute Micro prozessor das Ger t vollst ndig ab alle LEDs erl schen damit auch die Batterie eines vergessenen FlowMarkers sich nicht ber kurz oder lang zerst rerisch tief entl dt Der SAFEX FlowMarker Modell II ist auch hervorragend station r einsetzbar wobei die Nebelerzeugung in diesen F llen dann vorteilhaft mit einer Fernsteuerung ausgel st wird Dazu ist das Ger t mit einer FERNSTEUERBUCHSE ausger stet an die eine optio
14. ce are now controlled by a microprocessor which allows improved operation equipped with more features The unit now contains as standard a remote control socket for instant connection with a remote control The activation of the FOG FLOW will now be done by an ON OFF Switching Switching function no longer touch function The fog flow is now turned on by a short push onto the blue FOG button and as well shut off by pressing the button again in the same way as it has to be done with the new remote control s Dueto the new integrated microprocessor the device automatically switches into the so called ENERGY SAVING MODE for saving some battery capacity if no fog production is been done It further will be switched into the so called SLEEP MODE when continuously not be used and finally after a longer non use the unit turns itself off completely _ The battery capacity is spared in this way the unit will remain longer ready for use and also a harmful deep discharge of the battery is prevented The SLEEP MODE ensures that the unit uses very little battery power but it remains active for remote control In addition to the automatic shutdown after prolonged non use or lack of battery power the device is now also equipped with a manual shut off function with which it can be turned off at any time completely In addition the new MODEL II is optimized for new accessories A SYSTEM DESCRIPTION The SAFEX FlowMarker
15. chen versehenen Abschnitte sind besonders wichtig und sollten unbedingt beachtet werden Der SAFEX FlowMarker Modell II ist gegen ber seinem Vorg ngermodell erheblich verbessert worden Funktionen des Ger ts werden jetzt durch einen Mikroprozessor gesteuert der eine verbesserte mit mehr Funktionen ausgestattete Bedienung erm glicht Das Ger t enth lt nun standardm ig eine Fernsteuerbuchse zum sofortigen Anschluss einer Fernsteuerung Die Ausl sung der Nebelfunktion erfolgt jetzt durch AN AUS Schaltung Schaltfunktion nicht mehr Tastfunktion der Nebelfluss wird jeweils durch ein kurzes Dr cken des blauen NEBEL Knopfs an bzw ausgeschaltet genauso wie dies jetzt standardm ig mit jeder Fernsteuerungen erfolgen kann _ Durch den jetzt integrierten Mikroprozessor schaltet sich das Ger t selbstt tig bei Nichtverwendung nach einiger Zeit in einen Akku schonenden Spar sowie danach in einen sog Schlafmodus und bei l ngerem Nichtgebrauch sogar selbstst ndig aus Auf diese Weise wird die Batteriekapazit t geschont das Ger t bleibt l nger betriebsf hig und auch eine sch dliche Tiefentladung des Akkus wird sicher verhindert Der Schlafmodus sorgt daf r dass das Ger t nur wenig Akkukapazit t verbraucht jedoch f r Fernsteuerungen aktiv bleibt Neben der automatischen Abschaltung nach l ngerer Nichtbenutzung oder Batteriemangel ist das Ger t jetzt auch mit einer manuellen Abschaltfunktion aus
16. consisting of FM HYDRA HOSE ATTACHMENT hoses and other accessories see separate information sheet FlowMarker APPLICATION TUBE EXTENSION AR3 75 cm long extension for slipping over the application tube to bring out the fog even at difficult positions FLOWTRACER 75 cm long fog filament curtain extension tube with holes for the generation of a fog filament curtain See separate information sheet FlowMarker POWER CORD 10 m flexible thin cable for permanent power supply for the FlowMarker by means of the existing battery AC charger adapter 19 34 GA FM I 01 12 H TECHNICAL DATA FLOWMARKER OPERATION VOLTAGE POWER INPUT POWER SUPPLY INTERNATIONAL DIMENSIONS WEIGHT WEIGHT INCLUDING TRANSPORTATION CASE AND ACCESSORIES BATTERY BATTERY CHARGING TIME OPERATING TIME BATTERY ENERGY SAVING MODE OF DEVICE SLEEP MODE OF DEVICE SELF SHUTOFF OF DEVICE HEAT UP TIME FOGGING AGENT TANK VOLUME FLUID CONSUMPTION FOG PERFORMANCE FLUID CAN 12 Volt DC from internal battery 3 4 A in heating operation Heating power 40 W fuse intern 5 x 20 mm 6 3 A medium time lag for all international voltages with adapters for EU GB USA Australia wall outlets CE UL listed 100 240 V AC 50 60 Hz 250 mA 18 VA Output 12VDC 1A 12VA length 210 mm without application tube with standard application tube 500 mm width 90 mm height incl
17. d nicht verbrannt werden und sollte nur entleert im Hausm ll entsorgt werden Die Batterie des FlowMarkers ist eine versiegelte Blei S uregel Batterie Sie ist den Vorschriften entsprechend in Deutschland BattG zu entsorgen wenn sie nicht mehr verwendungsf hig ist Keinesfalls darf die Batterie ge ffnet verbrannt oder die Batteriepole kurzgeschlossen werden F r den Fall dass 7 durch Bruch S uregel aus der Batterie austritt sind betroffene K rperpartien sofort mit reichlich Wasser abzusp len bei Augenkontakt ist nach dem sofortigen Aussp len unverz glich ein Arzt aufzusuchen W hrend des Gebrauchs muss die Batterie mittels der Batteriefach Sicherungsschraube gegen Herausfallen gesch tzt sein Siehe Abschnitt B unter BATTERIE EINSETZEN Batterie w hrend des unbeaufsichtigten Transports aus dem Ger t entnehmen Batteriepole dabei nicht durch leitf hige Materialien kurzschlie en BRANDGEFAHR Batteriepole beim Transport ggf abdecken bzw abkleben GAFM II 01 12 34 32 RUTSCHGEFAHR NEBELFLUIDDOSE BATTERIE 33 34 1 01 12 FREMDE FLUIDE ANDERE FEHL BEHANDLUNGEN Das Ger t nimmt ernsten Schaden wenn andere Substanzen als SAFEX FlowMarker NEBELFLUID eingebracht werden Auch andere Nebelfl ssigkeiten Aerosoldosen von SAFEX oder anderen Herstellern sind ungeeignet HINWEIS Der Betrieb mit fremden Fl ssigkeiten oder ein ffnen des Ger tes w hrend
18. dass er hinter den Luft ffnungen ohne diese zu verdecken am Anschlag zu sitzen kommt Der kleinere Ring KR3 wird von vorne in die D se des jeweiligen schwarzen Rohres eingeschoben Die Ringe nehmen eventuell austretendes Kondensat auf und trocknen ggf wieder aus Sie m ssen jedoch bei intensiverem Gebrauch des Ger tes erneuert werden wenn ihre Aufnahmekapazit t ersch pft ist sie also v llig durchtr nkt sind Das Entfernen des vorderen Ringes erfolgt mit dem Hilfs Kunststoffrohr mit dem der Ring nach vorne ausgesto en werden kann Der hintere Ring nahe dem Applikationsrohr Gewinde sollte durch Durchsp len des Rohres mit warmem Wasser erweicht und dann von der Gewindeseite entnommen werden Ggf ist das Rohr f r einige Minuten in lauwarmes Wasser einzutauchen um den Ring aufzuweichen dabei k nnen Fluidreste und Verunreinigungen mit aus dem Rohr entfernt werden Das Rohr sollte erst trocken gewischt werden bevor es zur ck auf das Ger t montiert wird GAFM II 01 12 34 30 E LAGERUNG UND TRANSPORT Wird das Ger t l nger als 3 Monate nicht ben tigt und soll es nicht w hrend der Lagerung mit dem Netzteil verbunden bleiben so ist die Batterie nach abschlie ender Vollladung aus dem Ger t zu entnehmen Eine so vorbereitete Batterie ist ohne Schaden bis zu 2 Jahre lagerf hig Es muss darauf geachtet werden dass die Batteriekontakte bei Lagerung und Transport nicht durch leitf hige Materialien Metall Kohlenstof
19. diesen F llen ist das kurze Aufleuchten der roten LED nicht mit einem Batteriemangel gleichzusetzen FLUIDWEGE Zum optimalen Gebrauch m ssen die im Ger t befindlichen Fl ssigkeitswege nach jedem ENTL FTEN Auff llvorgang entl ftet werden a Ger t durch kurzes 1 maliges Bet tigen des blauen Nebelknopfes aktivie ren aufheizen b Nach vollst ndigem Aufheizvorgang der bei kaltem Ger t ca 30 Sek dauert gr ne LED BEREIT blinkt zun chst und leuchtet abschlie end permanent Ger t mit der D se bzw aufgesetztem Applikationsrohr senkrecht nach oben hal ten und mit einem kurzen Druck auf den Nebeltaster den Nebelfluss starten wei LED leuchtet bis gleichm ig Nebel austritt dies kann je nach vorhandener Luftmenge 10 30 Sek erfordern Ein weiterer Tastendruck stoppt den Nebel wieder Die Entl ftung kann nur senkrecht nach oben erfolgen GAFM II 01 12 34 24 INBETRIEBNAHME Das Ger t sollte dazu mit einem geladenen Akku versehen sowie mit ausreichend Nebelfluid bef llt sein Ger t durch kurze Bet tigung der blauen Taste starten die 3 Leuchtdioden blitzen kurz auf Das Ger t startet den Heizvorgang erkenntlich an einem sich steigernden Blinken der gr nen LED bis es die Betriebstemperatur erreicht hat welches an einem dauerhaften Aufleuchten der gr nen LED erkenntlich wird Das Ger t ist jetzt betriebsbereit Nebel kann jetzt innerhalb der n chsten 2 min ohne Verz ger
20. e LONG WP 1223 A 12 V 2 1 Ah SAFEX Qualit tskontrolliert
21. erie und Applikationsrohr AR1 ca 5 4 kg 12 V 2 1Ah Blei S ure Gelakku 20HR WP 1223 A min 2 Std 80 3 Std 100 bei st ndig eingeschaltetem Ger t ca 2 5 Stunden abh ngig von Dauer und H ufigkeit der Nebelerzeugung circa 2 min nach letzter Bet tigung des Nebeltasters 15 min andauernd circa 17 min nach letzter Bet tigung des Nebeltasters 2 h andauernd circa 2 h und 17 min nach letzter Bet tigung des Nebeltasters max 30 Sek bei kaltem Ger t ausschlie lich SAFEX FlowMarker NEBELFLUID Druckgasdose ca 18 ml ca 0 8 ml min bei Dauernebelerzeugung Tankinhalt reicht f r ca 21 min Dauernebel oder f r ca 420 Nebelzyklen von ca 3 sek Dauer Druckgaspackung klassifiziert nach UN 1950 DRUCKGASPACKUNG erstickend Inhalt 73 ml 75 g ausreichend fiir ca 2000 Nebelzyklen zu je ca 3 Sek OPTIONALES ZUBEHOR VERBRAUCHSMATERIAL UND ERSATZTEILE Siehe auch Kapitel G Optionales Zubeh r NEBELMITTEL KONDENSATAUFNAHMERINGE ERSATZFILTER ZUSATZLADEGER T INTENATIONAL RESERVEBATTERIE SAFEX FlowMarker NEBELFLUID Druckgaspackung mit 72 ml Packung mit 10 Stk Typ KR 3 Packung mit 10 Stk Typ KR 2 Packung mit 2 Filtern und 2 Dichtringen Steckernetzteil Ladegerat mit Ladeclip fiir Akku fiir alle Spannungen weltweit mit Steckadaptern fiir EU GB USA Australien CE UL gelistet 100 240 V AC 50 60 Hz 250 mA 18 VA Output 12 V DC 1A 12VA Blei Gelakku Typ
22. ery Einschub Batterie Figure 2 Abb 2 Use with application tube AR1 20 Neu Verwendung mit Applikatorrohr AR 1 Neu Thread for application tube Gewindeaufnahme f r Applikator Nozzle D se AR1 20 Neu with red or blue mark mit roter oder blauer Markierung Adjustment ring for air intake Verstellring Luftzufuhr charging battery SHEASIS AORN non Batterie laden 1 01 12 34 6 FLOWMARKER II Figure 3 Abb 3 Pressurized can Druckgasdose Battery charger Batterie Ladeger t Figure 4 Abb 4 Filling FLOW MARKER with FOG FLUID FLOWMARKER mit FOGFLUID bef llen Fill opening Bef ll ffnung Fill stem F llstift 7 34 GAFM II 01 12 SAFEX FLOWMARKER II MODIFICATIONES TO PREVIOUS MODEL For best use in all fields of application of the SAFEX FlowMarker Model Il it is recommended to read this instruction carefully even if one is already familiar with the previous model This instruction manual is to be supplemented if necessary with the instructions of each ancillary used optional FlowMarker accessory The safety instructions and all sections marked with the attention sign are especially important and should be given particular consideration The SAFEX FlowMarker Model II has been considerably improved compared to its predecessor functions of the devi
23. f r das Ladeger t als Sonderzubeh r zur Verf gung Mit diesem Zubeh rteil k nnen Reservebatterien unabh ngig vom Ger t geladen werden Dazu Ladeadapter Clip auf die Kontakte der Reservebatterie aufsetzen Ladeger t in vorschriftsm ige Steckdose 100 240 V stecken und so Batterie mind 2 Std vorzugsweise jedoch 3 Std aufladen Das Ende des Ladevorgangs wird durch einen Farbwechsel der LED am Ladeger t angezeigt Im Ger tetank befindliche Nebelfluide k nnen ohne Beeintr chtigung bis zu 2 Jahren im Ger t verbleiben Auch die SAFEX NEBELFLUID Druckgaspackung ist mindestens 2 Jahre lagerf hig Die Lagerung sollte nicht unter 15 C und bei max 30 C erfolgen Bei sehr langer Lagerung des Ger tes ist bitte der Hinweis bez glich des Tankkolbens am Anfang dieses Abschnitts zu beachten Durch sehr feine Konstruktionsdetails ist der SAFEX FlowMarker sehr empfindlich gegen Verschmutzung der Fl ssigkeitswege und des Nebelfluides selbst Daher m ssen die Bef llungs ffnung und das Dosenventil der Fluiddose vor Verschmutzung durch Fasern Fussel und klebrige Fl ssigkeiten aller Art gesch tzt werden Der Ventilstift der Fluiddose ist durch die Dosenkappe abzudecken er kann ggf mit war mem Wasser gereinigt werden Die Einf ll ffnung ist nach der Bef llung mit einem saugf higen Papier von ggf anhaften den Fluidresten zu reinigen und vor einer erneuten Bef llung von Fusseln und Staub mittels einer weichen
24. f Fasern Graphit Metallfolien usw kurzgeschlossen werden anderenfalls besteht ernste Brandgefahr Zum Transport ist der spezielle Koffer mit Facheinteilung f r das Zubeh r als Standardausstattung vorgesehen Dieser ist auch zur Aufnahme optionalen Zubeh rs wie z des FM HYDRA SCHLAUCHSYSTEMS und der FUNKFERNSTEUERUNG vorbereitet In verpacktem Zustand z B als Luftfrachtgut sollte die Batterie des Ger tes in jedem Falle entnommen werden damit sich das Ger t nicht durch ungewollten Druck auf den Nebeltaster einschalten kann Au erdem sollten durch richtige Verpackung bzw Positionierung die Pole der Batterie im Koffer vor Kurzschluss gesch tzt sein Die Batterie ist im Kofferfach richtig positioniert wenn diese mit den blanken Polen vollst ndig mit dem Batterier cken nach oben in der Schaumstoffeinlage eingebettet ist Batterier cken ist oben wenn sich die seitliche Aufschrift in normaler Leselage befindet TRANSPORT 34 GAFM I 01 12 Alle SAFEX NEBELGER TE und ihr Zubeh r sind entsprechend der DIN VDE Vor schrift 0700 Teil 245 sowie den EU Richtlinien 2001 95 EG 2006 95 EG 75 324 JEWG und der Verordnung EG Nr 1272 2008 bzw den in deutsches Recht umge setzten entsprechenden Rechtsverordnung konstruiert und gefertigt und entspre chen damit den gesetzlichen Bestimmungen in der Europ ischen Gemeinschaft ALLGEMEINES Pas Ger t enth lt keine frei zug ngigen gef hrlichen Stoffe und lediglich ein
25. fog generation in these cases is then beneficial started with a remote control For this the device is equipped with a remote control socket to which an optional available SAFEX RADIO or CABLE REMOTE CONTROL can be connected see chapter 0 OPTIONAL ACCESSORIES By each short pressing of the pushbutton of the remote control the fog flow will be turned on or off again However it may depending on the ready state of the device possibly take some seconds until the fog is released The switching status is recognizable again at the SAFEX FlowMarker by the white LED white LED lights up fog function is activated Because the SAFEX RADIO REMOTE CONTROL consumes for its reception ability some energy it will consume somewhat more battery capacity as with the energy neutral SAFEX FlowMarker CABLE REMOTE CONTROL Special behavior when using a remote control Is the FlowMarker in the sleep or energy saving mode the fog function will be triggered too by pressing a remote control key During the required heat up phase the fog function cannot be switched off inadvertently In this way an unintentional switching off due to e g a key double activation is prevented because the user wants to start with the remote control the fog release The device can be also optionally equipped with the FlowMarker STATIV MOUNTING PLATE which allows to set up the device with an usual photo tripod with standard thread This accessory is a
26. ger stet mit der es jederzeit komplett abgeschaltet werden kann _ Dar ber hinaus ist das neue Modell Il optimal auf neues Zubeh r abgestimmt A SYSTEMBESCHREIBUNG Das SAFEX FlowMarker Nebelger t ist ein speziell zur Sichtbarmachung und visuellen Dokumentation langsamer und schwacher Luftstr mungen entwickeltes Nebelger t f r Wissenschaft und Technik welches mit den weltweit einzigartigen und vollkommen ungef hrlichen SAFEX Theaternebel Fluiden Nebel erzeugt Durch die Erzeugung eines impulsarmen und thermisch praktisch neutralen Nebelflusses k nnen selbst schwierigste Aufgaben der Str mungsvisualisierung gel st werden In str mungsberuhigten Bereichen k nnen z B selbst kleine Vertiefungen mit Nebel gef llt werden der wie Wasser flie end einen Nebelsee ergibt und dessen Oberfl che auch schw chste Luftbewegungen erkennen l sst Weiterhin stehen neue erg nzende Systemkomponenten wie z B das FM HYDRA SCHLAUCHSYSTEM zur Verf gung die es jetzt erm glichen den Nebel z ber GAFM II 01 12 34 22 Schl uche oder mittels verschiedener Sonden Nebelrechen u auch an schwierige Orte oder auf besondere Weise in Luftstr mungen Ger te etc einzubringen siehe dazu Abschnitt G OPTIONALES ZUBEH R Der SAFEX FlowMarker Modell II besteht der Grundausstattung aus SYSTEM dem FlowMarker Gerat selbst KOMPONENTEN einer Einschub Batterie Blei Gel Akku 12 Volt 2 1 Ah 20HR Ty
27. he tank piston of the FlowMarker may lock itself PISTON This is however not a real malfunction but can be fixed simply by giving a small amount of fog fluid into the tank with the fog fluid aerosol can in the same way as the device is to be filled This releases the piston and the device is working again BATTERY Ifthe battery voltage decreases below 11 V the red LED starts flashing With further MONITORING declining of the battery voltage the off phase of the red LED is becoming even shorter until it permanently lights at about 10 Volt When the battery has reached 9 5 V the device turns off automatically With this signaling the user recognizes at an early stage that the battery capacity comes to an end and in regards to its working program taking this in consideration CHARGING THE The battery is charged regularly inside the device The included international mains BATTERY charging adapter generates the necessary DC voltage It is connected to the device with the inserted battery via the power input socket see figure 3 The power supply must be plugged into a regular 100 240 V AC 50 60 Hz socket The battery is automatically charged with the FlowMarker switched on or off After two hours 80 of the loading is done after 3 hours the battery is 100 loaded This is is apparent on the color change of the charger LED For frequent use the device should regularly be connected to the power supply and if possible remain connected ove
28. ically dependent on how intensive the device is used The SAFEX FOG FLUID AEROSOL is under pressure The propellant N is non inflammable non toxic and environmentally safe The pressurized fog fluid can like any aerosol can must never be heated above 50 C opened by force or burned When entirely empty dispose of it with domestic refuse The battery of the FlowMarker is a sealed lead acid gel battery If it is no longer usable dispose of it according to local regulations By no means open or burn the battery or short circuit the battery poles Should in case of damage any acid gel escape from the battery immediately rinse the affected parts of the body with ample water If eyes are affected rinse first then immediately consult a physician Before use check the battery safety screw to prevent the battery from falling out See chapter B Inserting Battery For unattended transport take the battery out of the device Prevent the battery contacts from being short circuited by conductive materials Serious fire hazard During transport cover battery contacts with non conductive material e g insulating tape GAFM II 01 12 34 18 The FlowMarker will get seriously damaged if filled with other substances than SAFEX STRANGE FLUIDS FlowMarker FOG FLUID Other fog fluids from SAFEX or other manufacturers are also OTHER POSSIBLE unsuitable CAUTION Operation with unsuitable fluids or opening
29. if the FlowMarker is not used However they have to be replaced periodically depending on the intensity of use at the latest when they are completely soaked To remove the front ring KR3 use the attached plastic tube and push it out from the rear end To remove the KR2 ring flush the tube inside with warm water and let the ring get soft before pulling it out If necessary put the applicator tube end in warm water for some 15 min remove the ring Clean it from fluid residues and other impurities and wipe the tube completely dry before mounting it back to the FlowMarker STORAGE AND TRANSPORTATION E If the FlowMarker will not be needed for more than 3 months and will not be connected to the power supply during this time charge the battery completely and take it out of the device Such preparation makes the battery storable for up to 2 years without suffering any damage During storage and transportation strictly prevent the battery contacts from being short circuited by conductive materials such as metal carbon fiber graphite foils etc Otherwise there is a serious fire risk For the transport of the FlowMarker its transportation case with special compartments for the acces sories is intended as standard equipment It is also prepared to host optional accessories such as e g the FM HYDRA TUBE SYSTEM and the RADIO REMOTE CONTROL Especially when wrapping or packing the FlowMarker e g as flight baggage take the
30. illustration from the device by turning it counter clockwise with a coin 2 Take the white micro filter 30 my out of the filter cartridge preferably with tweezers and dispose of it At the same time remove also the black o ring seal 3 Gently push the new micro filter into the recess and put a new o ring into the groove The o ring must lie in the groove crease free and evenly Pay attention to absolute cleanness 4 Gently screw filter cartridge hand tight into the device with a coin Do not clean or re use the removed filter and do not clean the fill opening with any sharp object Never use the FlowMarker without a filter Even very small particles can lead to serious damage of the device Blockage of the fluid channels or the heat exchanger must not be removed with acid de scaling agent or other detergents this would seriously damage the device Appropriate repairs can only be carried out at the manufacturer s works or at approved service centers Heaters for exchange are available as spare parts GAFM II 01 12 34 14 CHARGING BATTERY EXTERNAL FLUID FILLING AND TANK CHANGING THE FILTER 15 34 1 01 12 FOG FLUID CAN AND FLUID PRESSURE CONDENSATE ABSORBING RINGS The fog fluid itself is harmless and no hazardous material The can however is under gas pressure and therefore classified as hazardous material according to international transport regulations as UN No 1950 AEROSOL as
31. l voltages with adapters for EU GB USA Australia wall outlets CE UL listed 100 240 V AC 50 60 Hz 250 mA 18 VA Output 12 VDC 1A 12VA type LONG WP1223A 12 V 2 1 Ah SAFEX quality proofed INHALTSVERZEICHNIS Ansicht und Beschreibung der Bedienungselemente 5 5 6 GEBRAUCHSANWEISUNG A Systembeschreibung 5 21 Ger tevorbereitung S 22 S 24 D Wartung und Pflege S 27 Lagerung und 5 30 Sicherheitshinweise 5 30 G Optionales Zubeh r una 5 33 Technische Dateien ee 5 34 GA FM II 01 12 34 20 21 34 GAFM I 01 12 SAFEX FLOWMARKER II NDERUNGEN ZUM VORMODELL Um alle M glichkeiten des neuen SAFEX FlowMarker Modell Il voll ausnutzen zu k nnen ist es empfehlenswert diese Gebrauchsanleitung einmal komplett zu studieren auch wenn man bereits mit dem Vorg ngermodell vertraut ist Diese Gebrauchsanweisung ist ggf auch durch die Gebrauchsanweisungen des jeweils zus tzlich verwendeten neuen und optionalen Zubeh rs f r den FlowMarker zu erg nzen Die Sicherheitsanweisungen und die mit dem Ausrufezei
32. lauen Nebelknopf bei aktiviertem Ger t kurz dr cken ggf startet kurz der Heizvorgang siehe zuvor danach erzeugt das Ger t den Nebel Dieser Schaltvorgang aktive Nebelerzeugung ist an der wei en LED NEBEL zu erkennen diese leuchtet permanent auf solange die Nebelproduktion aktiviert ist Dies gilt auch f r die Bet tigung des Ger ts mittels einer Fernsteue rung Diese Anzeige der aktivierten Nebelerzeugung ist hilfreich wenn z B deren Nebelfluss durch Luft in den Fluidwegen oder durch Verwendung eines Zusatz schlauchs eines langen Applikationsrohres usw nicht sofort sichtbar wird Zur Beendigung des Nebelvorgangs ist die blaue Taste erneut kurz zu bet ti gen Ausschaltvorgang wei e LED NEBEL erlischt Soll die Arbeit mit dem Ger t sofort beendet werden erfolgt das komplette Ausschalten durch einen 4 s langen andauernden Druck auf den blauen Nebelknopf dabei leuchten alle Leuchtdioden kurz auf nach dem Erl schen der roten LED ist das Ger t dann komplett abgeschaltet GER T AKTIVIEREN NEBELERZEUGUNG 25 34 1 01 12 GER T ABSCHALTEN ENERGIESPAR MODUS BETRIEB MIT FERN STEUERUNGEN Der SAFEX FlowMarker ist dazu konstruiert in allen Betriebslagen eingesetzt werden zu k nnen Der Nebel kann daher mittels des Applikationsrohres in jeder Ger telage an die gew nschte Stelle bzw in den zu untersuchenden Luftstrom gebracht werden Bei gef lltem Tank und vo
33. llst ndig geladener Batterie ist eine ununterbrochene Nebel erzeugung ber ca 21 Minuten m glich blicherweise wird der Nebelfluss jedoch nur wenige Sekunden ben tigt das Ger t also impulsweise benutzt Das FlowMarker Modell II ist mit einer Abschaltfunktion versehen die es dem Anwender jederzeit erm glicht das Ger t komplett stromlos zu schalten Dazu ist die blaue Taste dauerhaft 4 s lang zu bet tigen zun chst leuchtet die wei e LED kurz auf dann erlischt diese und die rote LED zeigt das Abschalten an indem auch sie verl scht Das Ger t ist damit intern stromlos geschaltet nur die Ladebuchse ist noch mit der Batterie verbunden Sind Zusatzger te z B das FM HYDRA SCHLAUCHSYSTEM an die Ladebuchse des FlowMarkers angeschlossen m ssen diese deshab immer separat abgeschaltet werden sie schalten sich nicht automatisch aus Jetzt ist sichergestellt dass sich der eingebaute Akku nicht sch dlich tief entladen kann Allerdings sollte dieser bei sehr langem Nichtgebrauch zuvor einmal komplett aufgeladen werden da dies die Lebensdauer der Blei Gelakkus erheblich erh ht Wird vom Anwender das Ausschalten des Ger tes vergessen schaltet sich dieses zun chst in den Schlafmodus und dann ebenfalls automatisch nach 2 h total ab F r eine m glichst lange Batterienutzungsdauer ist das SAFEX FlowMarker Modell II jetzt mit einem ENERGIE SPARMODUS ausger stet Wird nach Aktivierung der Ger teheizung innerhalb von
34. ly before the device is not in use for very long time because this significantly increases the service life of the lead gel battery For a as long as possible battery life the FlowMarker model II is now equipped with an energy saving mode If after activating of the device heating no fog has been produced within 2 minutes in other words the blue button has not be pushed the device is switching into the energy saving mode This mode is decreasing the heat exchanger temperature slightly but allows the user any time to press the fog button again The fog production starts than only with some seconds of delay maximum 6 seconds depending on the length of the interruption of use Is no fog is generated in this mode within 15 minutes the device automatically switches into the so called SLEEP MODE in which the heating functions come to a standstill Only if necessary inserted wireless or cable remote controls are supported yet Using a remote control or pressing the fog button on the device the SAFEX FlowMarker however can always be briefly activated heated up again This sleeping mode is maintained also for 2 hours Should this period pass without producing fog the built in microprocessor switches off completely the device all LEDs go out to ensure that the battery of a forgotten FlowMarker will not soon or later destructively deep discharged The SAFEX FlowMarker can excellently be used also stationary where the
35. n Beh ltern mit leicht brennbaren L sungsmitteln bzw in L sungsmitteldampf Ansammlungen ist daher unzul ssig Durch physikalische Vorg nge ist es unvermeidbar dass sich bei l ngerem Gebrauch etwas Fluid an den Innenw nden der Applikationsrohre niederschl gt Dieser Niederschlag kann mit einem Papiertuch ausgewischt oder mit Wasser abgesp lt werden Da u U auch Fluid zu Boden tropfen kann ist dieses aufzunehmen weil viskose Fl ssigkeiten eine Rutschgefahr darstellen Gleiches gilt f r ausgelaufenes Nebelfluid Als Zubeh r sind daher Kondensat Aufnahmeringe erh ltlich die an beiden Seiten des Applikationsrohres eingeschoben werden k nnen Der gr ere Ring KR2 wird von der Gewindeseite so in das Applikationsrohr eingeschoben dass er hinter den Luft ffnungen ohne diese zu verdecken am Anschlag zu sitzen kommt Der kleinere Ring KR3 wird von vorne in die D se des jeweiligen schwarzen Rohres eingeschoben Die Ringe nehmen eventuell austretendes Kondensat auf m ssen jedoch bei intensiverem Gebrauch des Ger tes regelm ig erneuert werden Die SAFEX NEBELFLUID Druckgaspackung steht unter Druck Das Druckgas ist unbrennbar ungiftig und umweltvertr glich Kurioserweise muss die Dose bzw das Gas nach internationalem Transportrecht als erstickend bezeichnet werden obwohl es ein nat rlicher Bestandteil der Luft ist Sie darf auch wie jede Spraydose nicht ber 50 C erw rmt nicht gewaltsam ge ffnet un
36. nal erh ltliche SAFEX FUNK oder KABEL FERNSTEUERUNG angeschlossen werden kann siehe Abschnitt OPTIONALES ZUBEH R Durch jeweils kurze Bet tigung der Schalttaste der Fernsteuerung wird der Nebelfluss ein bzw wieder ausgeschaltet Allerdings kann es je nach Bereitschaftszustand des Ger ts u U bis zum Austreten des Nebels einige Sekunden dauern Der Schaltzustand ist am SAFEX FlowMarker wieder durch die wei e LED zu erkennen wei e LED leuchtet Nebelfunktion ist aktiviert Da die SAFEX FUNKFERNSTEUERUNG f r eine Empfangsbereitschaft etwas Energie verbraucht wird mit dieser etwas mehr Batteriekapazit t verbraucht als mit der Energie neutralen SAFEX FlowMarker KABELFERNSTEUERUNG Sonderverhalten bei Benutzung einer Fernsteuerung Befindet sich der FlowMarker im Schlaf oder Sparmodus so wird durch Bet tigen einer Fernsteuerungstaste auch die Nebelfunktion mit gestartet W hrend der dazu notwendigen Aufheizphase l sst sich die Nebelfunktion nicht versehendlich wieder ausschalten Auf diese Weise ist ein unbeabsichtigtes Ausschalten durch z B eine Tastendoppel Bet tigung etc verhindert da der Anwender ja mit der Fernsteuerung den Nebel ausl sen will Das Ger t kann auch optional mit der FlowMarker STATIV MONTAGEPLATTE ausgestattet sein die es erlaubt das Ger t mit einem blichen Fotostativ mit Normgewinde aufzustellen Diese Ausstattung wird werkseitig vorgenommen kann aber auch an
37. nfalls nicht in Kinder hand AKTIVER BETRIEB _ Die D se des Ger tes siehe Abb 2 wird bis zu 300 C hei ein Ber hren w hrend des Nebelerzeugung Betriebes f hrt zu einer punktf rmigen Verbrennung Der austretende Nebelstrahl ist ber ca 10 cm zun chst hei er sollte daher ohne App likationsrohr nicht auf Personen insbesondere nicht auf das Gesicht gerichtet werden Gefahr hei er Spritzer Der erzeugte Nebel sollte frei in den Raum austreten k nnen und sollte nur mit Abstand mind 0 5 m auf Personen gerichtet werden Ein Applizieren des Nebels auf hei e Oberfl chen bzw direkt in offene Flammen gl hende Heizspiralen usw ist unzul ssig Der ansonsten unbrennbare und gesundheitlich unbedenkliche Nebel kann sich allerdings nur auf sehr hei en Oberfl chen gt 200 C und in gro en Flammen thermisch zersetzen Kleine Flammen wie Kerzen oder Labor brenner sowie bliche W rmequellen wie Leuchten Zentralheizungen andere geschlos sene Heizsysteme und elektrische Ger te k nnen jedoch unber cksichtigt bleiben Des Weiteren darf das Ger t nur unter trockenen Bedingungen eingesetzt nicht mit Wasser bergossen oder darin eingetaucht werden Jede Verschmutzung mit aggressiven Medien Staub L sungsmitteln usw kann zu ernsthafter Besch digung f hren Der SAFEX FlowMarker ist nicht zum Einsatz explosiver Atmosph re geeignet kein EX Schutz Ein Arbeiten damit in unmittelbarer N he von offene
38. o not put electric machines in operation which may have been and since the safety devices may be affected even if there is no damage visible from the out side In cases of doubt immediately disconnect the machine from power and send it in for repair 4 Unauthorized repair or tampering with the regulation devices can lead to serious hazards and damage to the machine E g with incorrect power cords and power supplys chargers or short circuit in the charging socket Repairs should only be made by authorized service centers 5 In any places with public admittance the machine must be out of reach for unauthorized persons Electric installation must fulfill national safety require ments Keep the device fluid can and spare parts out of children s reach The nozzle of the device see figure 2 heats up to 300 C Do not touch during opera tion Danger of burning The discharging fog jet is hot at first about 10 cm Never direct it to persons particu larly not to the face without application tube Danger of small but hot splashes Allow fog to be blown towards open space Never blow it directly on persons minimum safety distance 0 5 m GENERAL ACTIVE USE Fog generation 17 34 1 01 12 SLIP HAZARD FLUID CAN BATTERY Do not blow fog on hot surfaces into open flames or into glowing heating elements etc The normally non flammable and non toxic fog can decompose on hot red glowing surfaces gt 380
39. old operation mode also in the same way as it was previously usual with the predecessor model This working mode Secondary Mode is intended for users which do not prefer the new operational mode To change the operation mode the FlowMarker must be switched off first The blue button must be then permanently pushed over 10 sec while all 3 LEDs light up briefly but go out than completely With the still permanently pushed button the red LED will light up after about 10 seconds and must be deleted now 3 times by pressing GAFM II 01 12 34 12 TRIPOD MOUNTING POWER SUPPLY CABLE APPLICATION TUBE EXTENTION CHANGING OPERATIONAL MODE 13 34 1 01 12 the blue button With the last delete the device switches in the new secondary mode and is therefore ready for use The new mode is displayed as follows Flashing of the green LED indicates the secondary mode Flashing of the white LED indicates the primary mode The device turns off automatically in secondary mode not as before after 3 minutes but switches first for 0 5 h in the sleep mode To immediately turn off the device in the secondary mode press the blue fog button quickly four times in a row All LED s extinguish permanently mode change back to the primary mode is to maintain in the same way as previously described and also possible only after prior turn off D MAINTENANCE AND CARE RELEASING TANK Occasionally after prolonged non use t
40. on the power supply charger Remainders of the fog fluid in the tank can be kept there for up to 2 years without suffering any harm The pressurized SAFEX FOG FLUID AEROSOL is also storable for at least 2 years It should be stored not below minus 15 C and at a maximum temperature of 30 C For very long storage of the device please pay attention to the note at the beginning of this maintenance section Due to its very fine construction details the SAFEX FlowMarker is very sensitive to dirt in the fluid channels and in the fog fluid itself Therefore the fill opening and the valve of the fluid can must be protected from fibres fluff and any sticky liquids The fill stem little tube of the fluid can must be covered with its cap It can be cleaned with warm water After every filling clean the fill opening of remaining fluid with absorbent paper Before the next filling clean the opening of dust and fluff with a soft brush or warm water All case components are made of stainless steel But do not let any water get into the device As a matter of course the filling system of the FlowMarker has a highly efficient filter which can be easily changed if required If the fog fluid from a new can fills the tank only very slowly or not at all the cause may be unless the can is empty or depressurized a blocked filter in the fill opening In this case change the filter as follows 1 Unscrew the filter cartridge see
41. p WP1223A dem aufschraubbaren Applikationsrohr Typ AR1 einer Druckgaspackung FlowMarker NEBELFLUID Nebelmittel in Aerosoldose je 5 Kondensat Aufnahmeringen Typ KR3 und KR2 2 St ck im Applikationsrohr einem Kunststoffrohr zur Entfernung des Kondensatrings KR1 einem Steckernetzteil Ladegerat 12 V 1 100 240 V gt 12 VA zum Laden der Batterie sowie 4 internationalen Steckdosenadaptern der Gebrauchsanleitung sowie dem FlowMarker Transportkoffer mit Facheinteilungen GERATE VORBEREITUNG Vor dem Erstgebrauch sind das Ger t und sein Zubeh r Koffer Inhalt zun chst auf Un ALLGEMEINES versehrtheit und Vollst ndigkeit des Standardzubeh rs zu pr fen Besch digungen und das Fehlen von Teilen sind unmittelbar beim Transportunternehmen bzw dem Lieferanten oder seiner Service Stelle zu reklamieren Das Ger t ist werkseitig bereits zu ca 50 mit Nebelfluid bef llt und entl ftet um eine erste Erprobung zu erm glichen a Dazu Nebelfluid Dose senkrecht auf eine Unterlage stellen Ventilschutzkappe NEBELFLUID EINF LLEN abnehmen und Dose mit einer Hand festhalten Eine Bef llung ist nur mit dem Ventilstift Stem senkrecht nach oben m glich nicht jedoch in waagrechter oder anderer Position der Dose b Jetzt FlowMarker am Handgriff mit seiner D se nach oben so auf die Dose aufsetzen dass die auf der R ckseite des Ger tes befindliche Bef ll ffnung den F llstift Stem der Dose aufnimmt Ger t
42. phyxiatin class 2 Cat 5A The pressure gas is non flammable non toxic and ecologically harmless The pressure of the can is independent of the temperature It gets less with every filling Hence every filling of the tank takes several seconds longer In order not to deaerate the can incorrectly always fill the device with the fill stem of the can pointing up Filling in a horizontal or other position of the can is actual not possible For particular applications it may be necessary to generate only very small amounts of fog As the amount of fog discharge depends on the amount of the tank filling it may be advantageous to fill the tank only at one third or halfway It is unavoidable that some condensation will occur in the fog application tube during intensive use of the FlowMarker In well ventilated warm areas a possible fluid condensation for example on a could surface will dry up without leaving a residue In the application tube however it is likely that under intensive use the condensed fluid film will increase and fluid may drop out of the tube To avoid a slide risk condensation absorbing rings are available as an accessory The smaller ring KR3 has to be inserted from the muzzle side of the black tube The larger ring KR2 has to be inserted from the threaded side of the application tube until it fits in behind the air inlet holes at the recess The rings will absorb possible fluid condensation and may dry out
43. plastic ring on the application tube base serves as controllable air inlet By turning the ring the six air inlets in the application tube can be reduced or completely closed This has a considerable influence on the fog and its flow The fog can therefore be generated according to the user s requirements To collect the fog fluid that unavoidably condenses in the tube the enclosed condensation absorbing rings should be inserted according to section MAINTENANCE AND CARE on page 13 Manual use If one would like to manually work with the device briefly press the blue 100 button then the device produces the fog if necessary the heating process starts first shortly see previously This switching operation active mist generation is recognizable by the white LED FOG it will light up permanently as long as the fog production is activated This also applies to the operation of the device by means of a remote control This display of the activated fog generation is useful when for example the fog flow is not immediately visible due to air in the fluid channels or by using an additional fog ducting hose or long application tube etc To stop the fog production the blue button is briefly to be pressed again switch off process white LED FOG goes off Should the work with the device be immediately terminated the complete power off is achieved by a 4 long ongoing pressure on the blue button All LEDs fla
44. r night IMPORTANT Please make sure that during storage or transport the fog button cannot be inadvertently pressed for instance by objects lying on the device CHANGING more than one battery is available the device can be equipped quickly with a full load BATTERY tery Loosen the battery compartment safety screw hold the device upright with the nozzle showing up and slightly beat the edge of the battery compartment on the ball of the thumb of your open hand until the battery loosens and slides into your palm Then insert according to section B chapter INSERTING BATTERY page 9 a newly full loaded battery Afterwards always screw down the battery safety screw The FlowMarker is designed for operation only with original batteries The batteries sold by SAFEX are specially tested and guarantee a safe and optimal function similar batteries even of the same brand available on the market are partly of inferior quality and may be not recommended In addition to the possibility to charge the battery inside the device a charging adapter clip for the power supply is available as an extra accessory With this accessory you can charge spare batteries independent of the device Put the clip of the charging adapter on the contacts of the spare battery plug the power supply into a regular 100 240 outlet and charge the battery for at least 2 or better 3 hours The end of the charging process is indicated by a color change of the LED
45. rosive acid might escape FlowMarker is now ready for operation If the battery is empty it has to be charged with the battery charger the red LED BAT TERY first flashes afterwards it lights up permanently See for this section D MAINTENACE AND CARE Charging the battery In this way the user can recognize early on that a recharging of the battery is impending one can therefore usually performing its current investigation until to its final end If the red LED lights up permanently there is a remaining battery capacity of approx imately 2 6 minutes for producing fog depending on the battery conditions After that the unit turns off itself completely to protect the battery against deep discharge NOTE A short flash of all LED s happens when switching the power ON or OFF it is a signal monitoring In these cases the brief flash of the red LED is no sign of a battery defect DE AERATING For optimum performance de aerate the fluid ways in the device after every refill FLUIDWAYS Activate and heat up the FlowMarker by pushing the blue fog button the green LED will flash b The heating up takes about 30 seconds when the device is cold After complete heat up green LED Ready lights up permanently hold the device vertically with its nozzle or application tube pointing up Press the fog button shortly to start the fog production white LED lights up for about 45 seconds un
46. several homepages the most actual versions are available at e www safex de e www tintschl best de Deutsche Gebrauchsanweisung beginnt auf Seite 20 TABLE OF CONTENTS ILLUSTRATIONS AND DESCRIPTION OF COMPONENTS 5 5 6 Instruction Manual A System description ae ae 7 Preparing device for operation 8 Using FlowMarker 10 Maintenance and 13 Storage and 1 lt 15 Safety INSINICHONS 16 Optional 50 322222 18 Technical data 19 GA FM II 01 12 34 5 34 GA 1 01 12 Signal LED Signallampen FOG aktivated Nebel aktiviert Heating FLOWMARKER II Figure 1 Abb 1 Multi function button Fog on Multifunktionstaster Nebel Aktivierung EIN Remote Control socket Fernsteuerbuchse Power input socket 12 V DC Ladebuchse 12 VDC Heizung Battery Fill openingffilter cartridge Bef ll ffnung Filterkartusche Batterie Tank control window Tanksichtfenster Battery compartement safety screw Batteriefachsicherung Battery compartment Batteriefach Batt
47. sh up briefly after the red LED has gone out the device is completely turned off The SAFEX FlowMarker has been constructed for use in any position of operation By means of the application tube the fog can be applied at the desired place or into the ACTIVATING DEVICE GENERATING FOG 11 34 GAFM I 01 12 TURNING OFF UNIT ENERGY SAVING MODE OPERATION WITH REMOTE CONTROLS airflow to be investigated in any position of the device When the tank is full and the battery completely charged fog can be generated continuously for about 21 minutes Usually the fog flow is only needed for some seconds i e the device will be used only impulsively The FlowMarker model II is equipped with a shut off feature it enables the user to turn the device completely off at any time For this the blue button must be pressed 4 s permanently First the white LED will light up briefly then it turns off and the red LED displays the switching off by extinguishing itself too after a second The unit is now internal completely powerless only the power input socket is still connected to the battery If there are additional devices connected to the charging socket of the FlowMarker g the FM HYDRA TUBE SYSTEM they must therefore always be switched off separately they cannot switch off automatically Now it is ensured that the built in battery will not be harmfully deep discharged However the battery should be charged complete
48. side the device together with 4 international wall outlet adapters the User Manual and the FlowMarker Carrying Case with compartments B PREPARING DEVICE FOR OPERATION Before first use check the device together with its accessories carrying case content GENERAL with regard to intactness and completeness of the standard parts Immediately report any damages or missing parts to the supplier or the supplier s service office The FlowMarker is delivered de aerated and with the tank approximately half full of fog fluid for a quick starting test a Place the fog fluid aerosol can upright on a solid base Remove the valve protection FILLING OPERATION cap Hold the can with one hand A filling is possible only with the valve pin stem pointing vertically upwards but not in horizontal or another position of the can b Hold the FlowMarker by its handle with the fog outlet pointing up Fit the fill Opening at the back of the device onto the valve stem of the can Make sure to hold the device upright with the tank control window being visible Press the can slightly against the device to inject the fog fluid from the can into the device Important No dust or dirt particles must get into the fill opening d filling procedure is visible in the tank control window The tank piston with the yellow mark moves towards the back of the device The filling procedure has to be stopped when the yellow mark has moved along
49. st Dazu keinesfalls vermehrte Kraft anwenden da sonst eine Besch digung des Batteriefachs unvermeidbar ist b Batterie jetzt in das Batteriefach des Ger ts so einschieben dass die Batterie mit der Beschriftung LONG nach oben und den Kontaktfl chen voraus im Batterie fach h rbar sp rbar einrastet und b ndig mit dem Geh use abschlie t Anschlie end Batterie Sicherungsschraube unbedingt wieder durch Rechtsdrehen festsetzen auch hier Schraube nur handfest anziehen d Diese Sicherungsma nahme ist erforderlich denn die Blei Gel Batterie soll te keinesfalls aus dem Ger t fallen k nnen da sie zerbrechen und tzende Batteries ure austreten kann e Das Ger t ist jetzt betriebsbereit Ist die Batteriekapazit t verbraucht muss die Batterie nachgeladen werden die rote Signal LED blinkt zun chst und leuchtet sp ter permanent auf Siehe dazu Abschnitt D Wartung und Pflege Auf diese Weise erkennt der Anwender recht fr h dass ein Nachladen der Batterie bevor steht er kann so in der Regel noch seine begonnene Str mungsuntersuchung zu Ende f hren Leuchtet die rote LED permanent stehen je nach Zustand der Batterie noch circa 2 6 min Batteriekapazit t zur Nebelerzeugung zu Verf gung Danach schaltet sich das Ger t zum Schutz vor Tiefentladung des Akkus komplett aus HINWEIS Ein kurzes Aufblinken aller LED s beim Einschalten oder Ausschalten des Ge r ts dient der Signal berpr fung in
50. t Ein Moduswechsel zur ck zum Prim rmodus ist auf die gleiche Weise wie zuvor be schrieben durchzuf hren und ebenfalls nur nach vorherigem Ausschalten m glich WARTUNG UND PFLEGE D TANKKOLBEN Gelegentlich kann sich nach l ngerem Nichtgebrauch der Tankkolben des FlowMar L SEN ker festsetzen Dies ist jedoch kein wirklicher Defekt sondern kann einfach behoben werden indem man mit der Nebelfluid Aerosoldose wie beim Auff llen einen kleinen Nebelfluidsto in den Tank gibt Dabei l st sich der Kolben und das Ger t funktioniert sofort wieder BATTERIE Sinkt die Akku Spannung unter 11 V so beginnt die rote LED zu blinken Bei weiter BERWACHUNG sinkender Akkuspannung werden die AUS Phasen der roten LED immer k rzer bis sie bei circa 10 Volt permanent leuchtet Unterschreitet der Akku 9 5 V schaltet sich das Ger t automatisch ab Durch diese Signalgebung erkennt der Anwender fr hzeitig dass die Batteriekapazit t zu Ende geht und er kann sich hinsichtlich seines Arbeitsprogramms darauf einstellen LADEN DER Die Batterie wird regul r im Ger t geladen Das mitgelieferte international verwendbare BATTERIE LADEGER T erzeugt die erforderliche Gleichspannung und wird ber die LADEBUCHSE siehe Abb 1 mit dem Ger t bei eingesetzter Batterie verbunden Das Ladeger t selbst ist in eine vorschriftsm ige Netzsteckdose mit 100 240 V 50 60 Hz einzuste cken Das Laden der Batterie erfolgt nach Netzverbindung au
51. til the fog comes out evenly A pushing of the blue button stops the fog production than De aerating can only be carried out in upward direction USING FLOWMARKER Il GAFM II 01 12 34 10 The device should be equipped with a charged battery the application tube and filled with an appropriate amount of fog fluid Start device by short pressing of the blue button the 3 LED s flash up briefly The device starts the heating operation recognizable by the increased flashing of the Green LED until it reaches the operating temperature after approximately 20 to 30 seconds This is recognizable by a permanent lighting up of the green LED The device is now ready for use Fog can be created now within the next 2 minutes without delay If the 2 minutes elapse without any fog produced the unit switches for 15 minutes in the energy saving mode which spares the battery capacity In this mode however fog can be produced at any time with a short delay of maximum 6 s To use the special advantages of the patented SAFEX FlowMarker the FOG APPLICATION TUBE is necessary for low impulse and thermal neutral fog generation By default the device is equipped with the 30 cm long version AR1 with the silver basic threaded part and a black plastic pipe 20 mm 00 Due to its special design and material the escaping fog is brought to the surrounding room temperature and is flow technological calmed down In addition a black
52. tomatisch auch bei ausge schaltetem Ger t Eine 80 ige Ladung ist nach ca 2 Std erreicht eine 100 ige La dung ben tigt ca 3 Std und ist am Farbwechsel der Ladeger t LED erkenntlich Bei h ufigem Einsatz empfiehlt es sich das Ger t bei Nichtgebrauch immer wieder mit dem Ladeger t zu verbinden und ggf auch ber Nacht am Netz zu belassen WICHTIG Es muss sichergestellt sein dass der Nebeltaster nicht bei Lagerung oder Transport versehentlich bet tigt wird z B durch darauf liegende Gegenst nde Stehen mehrere Batterien zur Verf gung kann das Ger t auch kurzfristig mit einer vollgeladenen AUSTAUSCH BATTERIE versehen werden Dazu Batteriefach Sicherungsschraube l sen Ger t ber einem Tisch o mit der D se nach oben halten und mit der Batteriefachkante leicht auf den Handballen der ge ffneten Hand schlagen bis sich die Batterie l st und in die Handfl che gleitet Anschlie end gem Abschnitt B unter BATTERIE EINSETZEN S 23 eine frische Batterie einsetzen Sicherungsschraube anschlie end unbedingt wieder anziehen Das Ger t ist nur f r den Betrieb mit Originalbatterien vorgesehen Die von vertriebenen Batterien sind speziell gepr ft und garantieren sichere und optimale Funktion gleichartige am Markt erh ltliche Akkus sind zum Teil von minderwertiger Qualit t und k nnen nicht empfohlen werden Neben der M glichkeit die Batterie im Ger t zu laden steht ein Ladeadapter Clip
53. ttached usually by the factory but can also be retrofitted to existing devices e g by service stations In particular for stationary as well as for mobile applications it can be useful to operate the FlowMarker permanently with power supply This is now possible with the 10 metre FlowMarker POWER CABLE with which the SAFEX FlowMarker will be connected to the standard battery AC charger adapter Due to the so established network connection the FlowMarker is virtually unlimited operational only smoke fluid must be refilled if necessary For this however disconnect temporarily the power supply For special applications extension tubes are available or can be developed Presently the following variations are available APPLICATION TUBE EXTENTION AR3 75 cm length furnished with a tube fitting system for an application length of up to 1 8 m This accessory is suitable for the investigation of airflows at ceilings and smoke detectors NEW is the also 75 cm long FLOWTRACER FOG FILAMENT CURTAIN DEVICE which is fitted in the same way on the application tube and is a simple solution for creating a fog filament curtain with 9 fog filaments with a distance of 8 cm With the newly developed optional available FM HYDRA TUBESYSTEM the fog filament curtain can still become improved because with it an additional air injection with variable speed comes to use The FlowMarker II also offers the possibility to work with it in the
54. ung erzeugt werden Verstreichen die 2 min ohne dass Nebel erzeugt wird schaltet das Ger t f r 15 min in den Sparmodus der die Batterie schont Es kann jedoch aus diesem Sparmodus heraus mit einer kurzen Verz gerung von maximal 6 s jederzeit Nebel erzeugt werden Um die besonderen Vorteile des patentierten SAFEX FlowMarkers nutzen zu k nnen ist f r impulsarme und thermisch neutrale Nebelerzeugung das NEBEL APPLIKATIONS ROHR erforderlich Standardm ig ist das Ger t mit der 30 cm langen Version AR1 mit silbernem Basis Gewindeteil sowie einem schwarzem Kunststoffrohr 20 mm AQ ausger stet Durch die besondere Form und den Werkstoff wird der aus dem Ger t austretende Nebel mit dem Applikationsrohr auf Raumtemperatur gebracht und str mungstechnisch beruhigt Zus tzlich ist die Applikatorbasis mit einer regelbaren Luftzufuhr in Form eines schwarzen Kunststoffringes versehen Durch seitliches Verdrehen des Ringes k nnen die sechs Luftzuf hr ffnungen im Applikator verkleinert oder ganz verschlossen werden was deutliche Auswirkung auf den Nebel bzw sein Flie verhalten hat So kann der Nebelfluss den Erfordernissen des Anwenders angepasst werden Zum Auffangen des unvermeidlich im Applikationsrohr entstehenden Nebelfluid Niederschlags sind die Kondensatringe in das Rohr gem Abschnitt D WARTUNG UND PFLEGE auf Seite 27 einzusetzen Manuelle Benutzung M chte dem Ger t manuell arbeiten b
55. ung zus tzlich zum Einsatz kommt 1 01 12 34 26 STATIV MONTAGE NETZKABEL APPLIKATIONSROHR VERL NGERUNG 27 34 GAFM II 01 12 BETRIEBSMODUS Der FlowMarker II bietet auch die M glichkeit in der alten Betriebsart zu arbeiten WECHSELN also in gleicher Art und Weise wie es bisher mit dem Vorg ngermodell blich war Diese Betriebsart Sekund r Modus ist f r Anwender gedacht die sich nicht mit der neuen Betriebsweise anfreunden k nnen Um die Betriebsart zu wechseln muss zun chst der FlowMarker ausgeschaltet werden Anschlie end ist die blaue Nebeltaste insgesamt 10 Sek dauerhaft zu dr cken dabei leuchten zun chst alle 3 Leuchtdioden kurz auf verl schen dann jedoch vollst ndig Bei weiter gedr ckter Taste leuchtet nach circa 10 Sek die rote LED auf und muss jetzt 3 mal durch kurzes Dr cken der blauen Taste gel scht werden Beim letzten L schen schaltet das Ger t in den neuen Sekund r Modus und ist damit betriebsbereit Der neue Modus wird wie folgt angezeigt Blinken der gr nen LED signalisiert den Sekund rmodus Blinken der wei en LED signalisiert den Prim rmodus Das Ger t schaltet sich im Sekund rmodus nicht wie fr her nach 3 min automatisch aus sondern schaltet zun chst noch f r 0 5 h in den Schlafmodus Um das Ger t im Sekund rmodus sofort auszuschalten die blaue Nebeltaste schnell viermal hinterei nander bet tigen Alle Leuchtdioden erl schen dauerhaf
56. usive handle 135 mm 2 66 kg including battery and application tube AR1 5 4 kg including battery and application tube AR1 12 V 2 1 Ah lead acid gel battery type WP1223A SAFEX quality proofed min 2 hours 80 3 hours 100 for constantly switched on device circa 2 to 5 hours dependent on duration and frequency of fog generation circa 2 minutes after last pressing fog button lasting 15 min circa 17 minutes after last pressing fog button lasting 2 hours circa 2 hours 17 minutes after last pressing fog button max 30 seconds for cold device max 6 sec in energy saving mode exclusively SAFEX FLOWMARKER FOG FLUID aerosol can circa 18 ml circa 0 8 ml min for continuous fog generation tank volume lasts for circa 21 minutes continuous fog or for about 420 fog cycles of circa 3 seconds each pressurized can according to UN No 1950 AEROSOLS volume 73 ml 75 g sufficient for about 2000 fog cycles of circa seconds each OPTIONAL ACCESSORY amp SPARE PARTS see also chapter G Optional Accessories FOGGING AGENT CONDENSATION ABSORBING RINGS SPARE FILTERS BATTERY CHARGER INTERNATIONAL SPARE BATTERY SAFEX FLOWMARKER FOG FLUID pressurized aerosol can with 72 ml pack containing 10 pieces type KR 3 since version 05 2005 pack containing 10 pieces type KR 2 pack containing 2 filters and 2 seal rings power supply with battery clip for external battery charging for all internationa
57. vorhandenen Ger ten nachger stet werden z B auch von Service Stationen Insbesondere f r station re aber auch f r mobile Anwendungen kann es sinnvoll sein den SAFEX FlowMarker st ndig mit Netzversorgung zu betreiben Dies ist jetzt mit dem 10 m langen FlowMarker NETZKABEL m glich mit dem der SAFEX FlowMarker mit dem Standard Ladeger t Lade Netzteil verbunden wird Durch die so hergestellte st ndige Netzverbindung bleibt der FlowMarker praktisch unbegrenzt betriebsf hig lediglich Nebelfluid muss bei Bedarf nachgef llt werden Dazu Netzverbindungen jedoch vor bergehend trennen F r spezielle Anwendungen sind Verl ngerungsrohre lieferbar bzw k nnen auch nach Kundenwunsch hergestellt werden Standardm ig steht z Z folgende Ausf hrung zur Verf gung FM APPLIKATIONSROHR VERL NGERUNG AR3 75 cm lang mit Steckmuffe mit dem eine Anwendungsl nge von 1 00 m erreicht wird Diese Ausstattung ist speziell zur Untersuchung von Luftstr mungen an Zimmerdecken oder z B von Rauchmeldern vorgesehen NEU ist der ebenfalls 75 cm lange FLOWTRACER NEBELRECHEN der auf gleiche Weise auf das Applikationsrohr gesteckt wird und dann eine einfache L sung zur Erzeugung eines Nebelvorhangs mit 9 Nebelf den im Abstand von 8 cm darstellt Mit dem neu entwickelten als Zubeh r erh ltlichen FM HYDRA SCHLAUCH SYSTEM l sst sich der Nebelvorhang Effekt noch verbessern da hier eine zus tzliche regelbare Luftzuf hr
58. zt Filterkartusche wieder in das Ger t schrauben und mittels M nze handfest anziehen Der ausgebaute Filter sollte nicht gereinigt oder wiederverwendet werden auch ist eine Reinigung der Bef llungs ffnung mittels spitzer Gegenst nde unangebracht Das Ger t sollte auch unter keinen Umst nden ohne Filter betrieben werden da bereits kleinste Partikel zu einer ernsthaften reparaturaufwendigen Besch digung des Ger tes f hren k nnen Eine Verstopfung der Fl ssigkeitswege oder des W rmetauschers kann nicht mit S uren Entkalkern oder anderen Reinigungsmitteln behoben werden ohne das Ger t ernsthaft zu zerst ren Eine sachgerechte Reparatur ist nur im Herstellerwerk m glich Austausch W rmetauscher stehen als Ersatzteil zur Verf gung Das in der Fluiddose befindliche Nebelmittel ist ungef hrlich und kein Gefahrstoff die Dose steht jedoch unter Gasdruck und ist daher als Gefahrgut im Sinne internationaler Transportvorschriften als UN Nr 1950 DRUCKGASPACKUNG erstickend Klasse 2 Kat 5A anzusehen Das Druckgas ist unbrennbar ungiftig und umweltneutral Nach ADR RID Vorschriften unterliegen SAFEX FlowMarker NEBELFLUIDDOSEN in Kontinentaleuropa in Packst cken bis 30 kg brutto jedoch sehr erleichterten Bedingungen beim Transport auf der Stra e bzw mit der Eisenbahn und m ssen u a lediglich gut verpackt und gekennzeichnet sein ADR RID 3 4 1 ehemals LQ Regelung Der Druck der Dose ist temperatur unabh ngig er