1. 4 MITSUBISHI ELECTRIC Air Conditioning Control System Centralized Controller AE 200A AE 50A AE 200E AE 50E CE Instruction Book Web Browser for User Contents Nes TAO UIC EOI reeniras EEEa 2 1 1 Terms Used in This Manual ccccccseccseecseeseeeseeeeeeeeeeeaeees 2 1 2 PC Requirements scscsccccrascocenencsenccesccnnedsxetewecencencetbunesdechoieeceteects 2 2 Setting the Operating Environment ccccccesseeeeeeees 3 2 1 Setting the IP Address of the PC a nnnnnnnnnnnnnnnnnnesnnnnnnnnnesnrnnnnne 3 2 2 Setting the Web BrOwSel sscgacoseunceteocand cettectes cenearetensectedewntsetentecen 5 3 Logging in to the Web Browser for USefL sccceeeeeees 8 4 Monitor Operation aiccuiwsancstarociusrndiontnaatinasenstanndeabegdieantionns 10 A 1 Condition 2 ee rr ee eee er a ee mere aie tia 10 Before using the controller please read this Instruction Book carefully to ensure proper operation Retain this manual for future reference 1 Introduction This Instruction Book explains how to monitor and operate the units connected to the AE 200A AE 50A and AE 200E AE 50E using a Web browser 1 1 Terms Used in This Manual Centralized Controller AE 200A AE 200E is referred to as AE 200 Centralized Controller AE 50A AE 50E is referred to as AE 50 Booster unit and Water HEX unit are referred to as Air To Water PWFY unit Hot Wat
2. Set temperature coi o ES PE p pe Cm f p EKE Air direction Filter Sign Reset Reset K Fan speed of interlocked LOSSNAY Filter Sign Reset Cancel Oke OK iick i Click to reflect the changes ick to return to the made previous screen without R0 making any changes Click Air conditioners to display the operation conditions of air conditioning unit groups Air conditioners HWHP LOSSNAY unit groups Air To Water PWFY unit groups and general equipment groups and click HWHP to display the operation conditions of HWWHP CAHV unit groups Click ON or OFF to turn on or off the units in a given group ON OFF Note Switching this switch will turn on or off the LOSSNAY unit as well that is interlocked with the operation of indoor units in the group To turn on or off the LOSSNAY unit only use the Interlocked LOSSNAY ON OFF switch Click the desired operation mode Air conditioning unit Cool Dry Fan Heat Auto Setback LOSSNAY unit Heat Recovery Bypass Auto Air To Water PWFY unit Heating Heating ECO Hot Water Anti freeze Cooling HWHP CAHV unit Heating Heating ECO Hot Water Anti freeze Note Only the operation modes available for the unit model will appear Note The Setback mode can be selected on the AE 200A AE 50A but not on the AE 200E AE 50E Click L J or CF to adjust the set temperature of the air conditioning unit or the Air To Water PWFY unit No
3. 6 TCP IPv6 zag intemet Protocol Version 4 TCP IPv4 4 Link Layer Topology Discovery Mapper I O Driver Link Layer Topology Discovery Responder 4 In the Internet Protocol Version 4 TCP IPv4 Properties window Internet Protocol Version 4 TCP IPv4 Properties check the radio button next to Use the following IP address Enter the PC s IP address e g 192 168 1 101 in the IP address teeny Ore you eed an your retoranatr field and enter the subnet mask 255 255 255 0 unless otherwise ai specified in the Subnet mask field Use the folowing IP address IP address 192 168 1 101 In the Default gateway field enter the gateway address as necessary Note Consult the system administrator to decide the IP subnet mask and gateway addresses Subnet mask 255 255 255 0 Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server 5 Keep clicking OK or Close to close all windows Alternate DNS server E Validate settings upon exit WT07140x01 4 2 2 Setting the Web Browser Web browser setting varies with the Internet connection type See the sections below for how to make Web browser settings for different types of Internet connection To prevent unauthorized access always use a security device such as a VPN router when connecting the AE 200 AE 50 to the Internet 2 2 1 No Internet connection To
4. Feed discovery gt Windows Update F12 developer tools Sun Java Console Internet options 2 3 4 5 6 In the Internet Options window click the Connections tab Check the radio button next to Never dial a connection in the middle of the window Click LAN settings under Local Area Network LAN settings In the Local Area Network LAN Settings window check Bypass proxy server for local addresses and click Advanced In the Proxy Settings window enter the AE 200 AE 50 s IP address e g 192 168 1 1 in the Exceptions field Then keep clicking OK or Close to close all windows If connecting multiple AE 200 AE 50 units enter their addresses e g 192 168 1 1 192 168 1 2 It is also possible to use an asterisk as a wildcard e g 192 168 1 WT07140X01 7 Dial up and Virtual Private Network settings Bat Ceci Choose Settings if you need to configure a proxy server for a connection Never dial a connection Dial whenever a network connection is not present Always dial my default connection Current None Set default Local Area Network LAN settings eet aa erpa e a __LANsettings for dial up settings Automatic Stat may override manual say To ensure the use of manual se automatic configuration E Automatically ae F Use automatic configuration script Address Proxy server iy Use a proxy server for your LAN These se
5. monitor and operate the air conditioning units from a PC with no Internet connection follow the instructions below to set the environment for the Web browser 1 Click Tools in the menu bar then click Internet options 2 In the Internet Options window click the Connections tab 3 Check the radio button next to Never dial a connection in the middle of the window and click OK to close the window WT07140X01 5 Edit View Favorites UES Help _ Delete browsing history Ctrl Shift Del dd The webp ag InPrivate Browsing Ctrl Shift P Tracking Protection ActiveX Filtering Things to try Diagnose connection problems Scar Reopen last browsing session Add site to Start menu Make sure View downloads Ctrl J check mark Pop up Blocker gt J SmartScreen Filter For offline Mae cad cae Compatibility View Compatibility View settings Subscribe to this feed Feed discovery j Windows Update F12 developer tools Sun Java Console Internet options Internet Options General Security Privacy Content Connections Programs Advanced ip To set up an Internet connection click Setup Dial up and Virtual Private Network settings amp Dial up Connection Choose Settings if you need to configure a proxy connection server for a r Never dial a connection Dial whenever a network connection is not present Always dial my default connection Current N
6. multiple groups the LOSSNAY unit may be in operation even when the Interlocked LOSSNAY OFP icon is displayed 3 The Occupancy Vacancy status icon will appear only when Show occupancy icon Show vacancy icon or Show both icons is selected in the Occupancy sensor display section under the Display Format section of the Basic System settings screen accessible via the Web Browser for Initial Settings 4 The Occupancy Vacancy status icon will not appear if the remote controller in the group does not have an occupancy sensor 5 The Occupancy Vacancy status icon takes priority over the Interlocked LOSSNAY ON or Interlocked LOSSNAY OFF icon 6 The Brightness Darkness status icon will appear only when Show bright symbol Show dark symbol or Show both symbols is selected in the Brightness sensor display section under the Display Format section of the Basic System settings screen accessible via the Web Browser for Initial Settings 7 The Brightness Darkness status icon will not appear if the remote controller in the group does not have a brightness sensor 8 The Setback ON icon takes priority over the Brightness Darkness status icon 9 The Starting up icon will stay when the unit cannot be recognized after startup Check for proper connection of the air conditioning unit and proper group settings 10 The Hold function can be used on the AE 200A AE 50A but not on the AE 200E AE 50E WT07140X01
7. the unit is stopped Select Snow to operate the fan even while the unit is stopped Click Reset to switch between resetting and not resetting the filter sign The rectangular icon next to Reset will appear in yellow green when it is set to Reset ff Note If a filter sign in the group has not been triggered then the item Filter Sign Reset will not appear Click ON or OFF to turn on or off the interlocked LOSSNAY unit Note For a group that is not connected to an interlocked LOSSNAY unit ventilator the item Interlocked ventilator ON OFF will not appear Click La or to adjust the fan speed of the interlocked LOSSNAY unit ventilator Note For a group that is not connected to an interlocked LOSSNAY unit the item Fan speed of interlocked LOSSNAY will not appear Filter Sign Reset Interlocked LOSSNAY ON OFF Fan speed of interlocked LOSSNAY Prohibition icon E will appear next to the item whose operation is prohibited If one or more operation items are prohibited Centrally Controlled will appear 1 The item may not be displayed depending on the unit model Prohibition icon 4 1 4 Operating the units in all groups 1 In the Air conditioners display of the Condition List screen click Select the operation units Batch Operations If air conditioner group LOSSNAY unit ventilator group Air To Water PWFY unit group and general equipment group l 7 exist together in the same syste
8. 11 Description 2 LOSSNAY unit ventilator group _ a a Filter sign ON Group icons 4 This icon will not appear for the HWHP CAHV unit groups 2 The Water temperature display icon will not appear for the HWHP CAHV unit groups 4 General equipment group Note Besides the lighting icons pump or card key icons are also available The icon can be selected on the group settings screen accessible via the Web Browser for Initial Settings WT07140X01 12 4 1 2 Checking the operation conditions of HWHP CAHV unit groups In the Air conditioners HWHP section select HWHP to display the operation conditions of the HWHP CAHV unit groups Note The HWHP button will not appear if no HWHP CAHV units have been registered to any group G _ http 192 168 1 1 en index htm S __ MITSUBISHI Air Conditione j tans Batch Operations f File Edit View Favorites Tools Help Click to operate the units Monitor Operation MTSU in all HWHP CAHV unit Condition List groups at once Update I Condition List W Air conditioners ee Air conditioners HWHP Click to show the most Update Auto Manual Batch Operations Weekly1 in period recent operation conditions _ Heat Representative Temp Outdoor Temp Inlet Temp Outlet Temp peas hats te ma Weekly schedule number Group name E Indicates the weekly W Hot Representative Temp Outdoor Temp Inlet Temp Outlet Temp schedule
9. Ej 260 Wj 28 50 Conference Room B Conference Room C Soe S Poe Mae B a so W se Room humidity 9 Conference Room D 10 Conference Room E E o E an WAN 25 vE Heat E an WA on Group icons The icons indicate the operation conditions of groups Click the icon to switch to the operation screen Room temperature Operation mode Click Air conditioners to display the operation conditions of air conditioning unit groups Air conditioners HWHP LOSSNAY unit groups Air To Water PWFY unit groups and general equipment groups and click HWHP to display the operation conditions of HWHP CAHV unit groups Update Click to show the most recent operation conditions Batch Operations A oy the units in all groups HWHP CAHV unit groups excluded at once See The name of the group will appear Operation mode The operation mode of the group will appear The set temperature of the group will appear Note For Air To Water PWFY unit groups the set water temperature will appear Note The temperature unit C or F can be set on the Basic System settings screen accessible via the Web Browser for Initial Settings Set temperature Indoor unit return air temperature will appear Note The temperature shown may be different from the actual room temperature Room temperature Note For Air To Water PWFY unit groups the current water temperature will appear Note The temperature unit C or F c
10. an be selected on the Basic System settings screen accessible via the Web Browser for Initial Settings WT07140X01 1 0 Description The reading of the humidity sensor on the ME remote controller North America PAR U01MEDU Europe PAR U02MEDA will appear Room humidity Note If an ME remote controller North America PAR U01MEDU Europe PAR U02MEDA is connected to the group and the built in humidity sensor is enabled the reading of the sensor will appear Each group icon indicates the operation condition of the group Move the cursor to the icon to display its group name Clicking the icon will bring up the operation screen The icons to indicate the operation conditions are shown below 1 Air conditioning unit group 2 ____orF __ _trr_ Filter sign ON Interlocked Interlocked OSSNAY ON 1 5 LOSSNAY OFF 2 5 OFF 2 5 Schedule set Schedule disabled Blue Gray Group icons Yellow Gray Note Besides the 4 way airflow unit icons 2 way airflow or ceiling suspended unit icons are also available Icons can be selected on the group settings screen accessible via the Web Browser for Initial Settings 4 If the LOSSNAY unit is interlocked with the operation of Mr Slim units Interlocked LOSSNAY ON icon will appear even when the LOSSNAY unit is operated individually Applicable M NET adapter model PAC SF48 50 60 70 80 81MA E 2 Ifa LOSSNAY unit is interlocked with the operation of indoor units in
11. e Although the address bar will turn red and a message Certificate error will appear you can still access the Web browser t x WT07140X01 9 lt 4 Sea Ea Go d http 192 168 4 1 en index htm X J MITSUBISHI Air Conditione x int we 22 File Edit View Favorites Tools Help MITSUBISHI ELECTRIC H Login Page Type your u me and passwo User name Password Login R10 mu seca x Go hitps 192 168 1 1 en index html P amp X E MITSUBISHI air Conditione x nt we 93 File Edit View Favorites Tools Help The security certificate presented by this website was not issued by a trusted certificate authority server 4 Monitor Operation This chapter explains how to monitor the operation conditions of all groups collectively and how to operate each group or all groups collectively 4 1 Condition List On the Condition List screen the operation conditions of all groups can be monitored The operator can also check the unit malfunctions on this screen and prevent the units from being left on unintentionally This section explains how to monitor the operation conditions of all groups HWHP CAHV unit groups excluded collectively see section 4 1 1 how to monitor the operation conditions of HWHP CAHV unit groups see section 4 1 2 and also explains how to operate each group see section 4 1 3 o
12. er Heat Pump unit is referred to as HWHP CAHV unit Screen images used in this manual are from Windows 7 and Internet Explorer 9 0 Note Windows is a registered trademark or trademark of Microsoft Corporation in the United States and other countries 1 2 PC Requirements Table1 1 PC Requirements Microsoft Internet Explorer 8 0 Microsoft Internet Explorer 9 0 Microsoft Internet Explorer 10 0 Java execution environment is required Browser Oracle Java Plug in Ver 1 7 0_51 Install Oracle Java Plug in that is appropriate for your operating system When using a 64 bit Internet Explorer install a 64 bit Java Plug in The version of the Oracle Java Plug in can be verified by clicking Java in the Control Panel On board LAN port or LAN card 100 BASE TX Note Microsoft is a registered trademark or trademark of Microsoft Corporation in the United States and or other countries Oracle and Java are trademarks or registered trademarks of Oracle Inc in the United States and or other countries WT07140X01 2 2 Setting the Operating Environment This chapter explains how to make PC settings and Web browser settings to monitor and operate the air conditioning units 2 1 Setting the IP Address of the PC Follow the instructions below to set the PC s IP address for the Web browser to recognize the AE 200 unit The PC s IP address must have the same network address as the AE 200 AE 50 s IP addre
13. le via the Web Browser for Initial Settings The representative water temperature outdoor temperature inlet water temperature and outlet water temperature will appear Temperature Note When there is a communication error the temperature value will be Note The temperature unit C or F can be selected on the Basic System settings screen accessible via the Web Browser for Initial Settings The fan mode of the group will appear WT07140X01 1 3 4 1 3 Operating the units in a given group In the Air conditioners display of the Condition List screen click one of the group icons to display its operation settings screen which shows the current operation conditions Change the desired settings and click OK to reflect the changes Click Cancel to return to the previous screen without making any changes Note To operate an HWHP CAHV unit group click the icon of the group on the HWHP display of the Condition List screen Group name __J http 192 168 1 1 en index htm g __ MITSUBISHI Air Conditione X File Edit View Favorites Tools Help Centrally Controlled Monitor Operation mark Condition List Bigckianic W Condition List a Air conditioners HWHP Meeting room 1F ON OFF 2 eee Interlocked LOSSNAY O OFF entraily Controtie L Operation mode Mode Cool Dy Ean fHeat PAuto Setback RE Ventilation ON OFF Set Temp Air Direction Fan Speed HON OFF se KAS Fan speed
14. m a screen to select a group type will E Beat EO NONANEN appear Click one of the group types to change its settings e Note To operate all HWHP CAHV unit groups click Batch Operations in the Se All LOSSNAY HWHP display of the Condition List screen i ji All air to water a Other Equipment 2 On the operation settings screen change the desired settings and click OK to reflect the changes Click Cancel to return to the previous screen without making any changes ee oe Note The settable temperature range is limited for the group whose set fos Ts ye ar temperature restrictions settings have been made ae Note If any group out of the given groups has an operation item that is ee prohibited the item for the group can not be operated ma xe WT07140X01 1 5 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations e Low Voltage Directive 2006 95 EC e Electromagnetic Compatibility Directive 2004 108 EC e Restriction of Hazardous Substances 2011 65 EU Please be sure to put the contact address telephone number on this manual before handing it to the customer MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT07140X01
15. net Explorer gt 1 Click Tools in the menu bar then click Internet options 2 On the General tab click Delete in the middle of the window 3 In the Delete Browsing History window click Delete lt Java gt 1 Click Control Panel from the Start menu 2 Click the Java icon to launch the Java Control Panel 3 On the General tab click Settings in the Temporary Internet Files section 4 Click Delete Files 5 In the Delete Files and Applications window click OK H Login Page Note The web page will be displayed in the same language as the operating system on the PC The web page can be displayed in other languages by entering the web page address as follows Chinese http IP address of each AE 200 AE 50 zh index html English http IP address of each AE 200 AE 50 en index html French http IP address of each AE 200 AE 50 fr index html German http IP address of each AE 200 AE 50 de index html Italian http IP address of each AE 200 AE 50 it index html Japanese http IP address of each AE 200 AE 50 ja index html Portuguese http IP address of each AE 200 AE 50 pt index html Russian http IP address of each AE 200 AE 50 ru index html Spanish http IP address of each AE 200 AE 50 es index html Note You can add the web page address to your Favorites on the login screen for easy access in the future 2 Enter the user name and the password in
16. one Set default Local Area Network LAN settings LAN Settings do not apply to dial up connections Choose Settings above for dial up settings x _concet_ toot 2 2 2 Dial up Internet connection To monitor and operate the air conditioning units from a PC that connects to the Internet through a dial up connection follow the instructions below to set the environment for the Web browser 1 Click Tools in the menu bar then click Internet options File Edit View Favorites ETS Help 2 In the Internet Options window click the Connections tab 3 Check the radio button next to Dial whenever a network connection is not present in the middle of the window and click OK to close the window By making these settings a message will appear asking whether or not to use a dial up connection when an Internet connection is necessary Follow the message to connect to the Internet 2 2 3 Connecting to the Internet via proxy server using an existing LAN Oo The webpag Things to try Connect ta Make sure check mark For offline Delete browsing history Ctrl Shift Del InPrivate Browsing Ctrl Shift P Tracking Protection ActiveX Filtering Diagnose connection problems Reopen last browsing session Add site to Start menu View downloads Ctrl J k Pop up Blocker gt SmartScreen Filter gt Manage add ons Compatibility View Compatibility View
17. r all groups collectively see section 4 1 4 After login a Condition List screen will appear which shows the operation conditions of all air conditioning unit groups LOSSNAY unit ventilator groups Air To Water PWFY unit groups and general equipment groups 4 1 1 Checking the operation conditions of all groups HWHP CAHV unit groups excluded In the Air conditioners HWHP section select Air conditioners to display the operation conditions of air conditioning unit groups LOSSNAY unit ventilator groups Air To Water PWFY unit groups and general equipment groups Batch Operations Click to operate the units in all groups HWHP CAHV unit groups excluded at Monitor Operation once Condition List W Condition List Update Batch Operations _4 http 192 168 1 1 en index htm Pr eX __ MITSUBISHI Air Conditione File Edit View Favorites Tools Help E y Air conditioners HWHP U pdate sim ones lt eekly1 in period ee ee eS a Weekly schedule number recent operation conditions Entrance Lobby South Ei Heat a 50 See Aut 230 50 Zz ea By 257 HM 25 e m Auto lsc Al o Lobby East Lobby Center v A A E 30 C i Fan c FH 2c EA Auto o Wj 23 50 Indicates the weekly schedule that is currently i effective Group name Lobby West Conference Room A n Set temperature F Auto a Fl 25 test
18. settings Subscribe to this feed Feed discovery gt Windows Update F12 developer tools Sun Java Console Internet options Setup To set up an Internet connection click Dial up and Virtual Private Network settings Choose Settings if you need to configure a proxy server for a connection Always dial my default connection Current None Local Area Network LAN settings LAN Settings do not apply to dial up connections Choose Settings above for dial up settings oc canei ay To monitor and operate the air conditioning units from a PC that connects to the Internet through a proxy server by connecting to an existing LAN such as a LAN within your company follow the instructions below to set the environment for the Web browser 1 Click Tools in the menu bar then click Internet options Edit View Favorites BEHAR Help y a AN ttp 2 168 1 1 en in File WT07140X01 6 oO The webpag Things to try Connect ta Make sure check mark For offline Delete browsing history Ctrl Shift Del InPrivate Browsing Ctrl Shift P Tracking Protection ActiveX Filtering Diagnose connection problems Reopen last browsing session Add site to Start menu View downloads Ctrl J k Pop up Blocker gt SmartScreen Filter gt Manage add ons Compatibility View Compatibility View settings Subscribe to this feed
19. ss i e AE 200 s IP address 192 168 1 1 PC s IP address 192 168 1 101 When connecting an AE 200 AE 50 to an existing LAN consult the system administrator to decide the IP addresses Note When using an AE 200 AE 50 dedicated LAN it is recommended that the AE 200 unit be assigned an IP address between the range 192 168 1 1 and 192 168 1 40 the AE 50 unit be assigned an IP address between the range 192 168 1 211 and 192 168 1 249 and that the PC connected to the AE 200 AE 50 be assigned an IP address between the range 192 168 1 101 and 192 168 1 150 1 Click Control Panel in the Start menu 2 Click Network and Sharing Center gt Local Area Setting In the Local Area Connection Status window click Properties 3 Click Internet Protocol Version 4 TCP IPv4 to select it and click Properties WT07140X01 3 Computer Control Panel EI E Windows Media Center sass Calculator H En change settii LW Sticky Notes k Default Programs Q Snipping Tool Help and Support gt All Programs Shut down gt Sent A Received Bytes 28 418 1 084 650 Properties Disable Diagnose Local Area Connection Properties Connect using This connection uses the following items M 0 Client for Microsoft Networks M S a0 Packet Scheduler M 42 File and Printer Sharing for Microsoft Networks Intemet Protocol Version
20. te The settable temperature ranges depend on the unit model Note If the indoor unit supports the dual set point function in the AUTO mode and when the operation mode above is set to Auto or Setback two set temperatures for Cool mode and Heat mode can be set Set temperature 1 Note When the indoor units that support the dual set point function and the indoor units that do not support the dual set point function exist in the same group only one set temperature can be set in the AUTO mode Note The temperature range restrictions settings on the Set Temperature Range Limit settings screen on the Web Browser for Initial Settings will be effective on this screen Note The temperature unit C or F can be selected on the Basic System settings screen accessible via the Web Browser for Initial Settings Click Lai or F to adjust the air direction Mid 3 Horizontal Bee Operation mode 1 Air Direction 1 Note Available air directions depend on the unit model WT07140X01 14 Click Lai or to adjust the fan speed Mid 2 Mid 1 High EG SADE AE nin pargo See paag ETETEN JENTIA Note Available fan speeds depend on the unit model Fan Speed 1 This item will appear only on the operation settings screen for HWHP CAHV unit groups The fan can be set to keep rotating even while the unit is stopped to avoid snow Fan Mode 1 accumulation on the fan guard during the winter Select Normal to stop the fan while
21. that is currently 60 0 C 59 0 C KOC 55 0 C 60 0 C effective HWHP CAHV unit group HOS icons W Anti F Representative Temp Outdoor Temp Inlet Temp Outlet Temp s a r a _ 4 o o o o OO now The icons indicate the ma nl scl mre i ages Group4 operation conditions of W ECO Representative Temp Outdoor Temp Inlet Temp Outlet Temp groups 34 0 C 70 30 0 35 0 Click the icon to switch to the operation screen Fan mode Temperature 100 v Operation mode Set temperature Description Click Air conditioners to display the operation conditions of air conditioning unit groups Air conditioners HWHP LOSSNAY unit groups Air To Water PWFY unit groups and general equipment groups and click HWHP to display the operation conditions of HWWHP CAHV unit groups Update Click to show the most recent operation conditions P When Auto is selected the operation conditions are updated automatically every minute Batch Operations Click to operate the units in all HWHP CAHV unit groups at once HWHP CAHV unit group Each group icon indicates the operation condition of the group Clicking the icon will bring icons up the operation screen The name of the group will appear Operation mode The operation mode of the group will appear The set temperature of the group will appear Set temperature Note The temperature unit C or F can be selected on the Basic System settings screen accessib
22. the login screen and click Login A Condition List screen will appear which shows the operation conditions of groups Note Consult the building manager for your user name and password WT07140X01 8 Encrypting the communication data and logging in to the Web browser HTTPS connection AE 200 AE 50 can encrypt communication data using HTTPS SSL When connecting the AE 200 AE 50 to the LAN that is accessible to the general public it is recommended that the following settings be made so that the units are monitored and controlled on the encrypted web page Note Depending on the operating system or the Java version HTTPS encrypted communication may not be enabled properly If this happens use an HTTP connection as explained in the previous page 1 Prefix the web address with https enter the rest of the address and press the Enter key https IP Address of each AE 200 AE 50 index html Note If the IP address of the AE 200 AE 50 is 192 168 1 1 the web page address is https 192 168 1 1 index html The encrypted data communication will begin and the Login screen will appear If a security certificate error page appears instead of the Login screen go to step 2 below 2 If the security certificate is invalid a security certificate error page as shown at right will appear Click Continue to this website not recommended 3 If the connection is successfully made the Login screen will appear Not
23. ttings will not apply to W dial up or VPN connections Address 192 168 1254 Port 8080 Advanced V Bypass proxy server for local addresses Proxy address to use HTTP 192 168 1 254 Secure 192 168 1 254 ETP 192 168 1 254 Socks Use the same proxy server for all protocols Exceptions A Do not use proxy server for addresses beginning with Y 192 168 1 1 J Use semicolons to separate entries Ca Cad 3 Logging in to the Web Browser for User 1 Enter the web page address in the address field of the Web browser as follows http IP address of each AE 200 AE 50 index html Press the Enter key A login screen will appear Note If the IP address of the AE 200 AE 50 is 192 168 1 1 the web page address is http 192 168 1 1 index html Note Default IP address of AE 200 and AE 50 is 192 168 1 1 When one or more AE 50 controllers are connected none of their IP addresses should overlap The recommended IP address ranges are as follows AE 200 Between 192 168 1 1 and 192 168 1 40 AE 50 Between 192 168 1 211 and 192 168 1 249 Note Log in to the AE 200 or AE 50 Web browser respectively to monitor or operate the units that are under the control of AE 200 or AE 50 The Web browser cannot be switched between the AE 200 and the AE 50 Note If the login screen does not appear then take the steps below to delete the temporary files lt Inter