Contents

1. Max 12m Max 15m Max 3 5m also be grounded to avoid static electricity The suction motor on the boilers storage has limitations in which underpressure it can produce Therefore it is important that the hoses between the switch and the boiler are not too long We can guarantee the function according to the distances on the sketch if you want a longer distance there is a risk for reduced feeding and disruptions to the boiler It is paramount that the connections against nozzles and switches are tight If there are leaks the suction capacity deteriorates significantly Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta m Electrical connection NOTE The boiler must be filled with water before the wiring begins For wiring to the motherboard you need to use a standard screwdriver with a tip width of 3mm a length of about e 12cm You can open the spring load of the motherboard in both the tracks that are on every cable entry When it s time to do the electrical connection you need to remove the front casing which is in front of the motherboard On the backside of the b
2. EFFECTA AB Vastra Ragdalsvagen 21 434 99 kungsbacka Tel 46 300 22320 Fax 46 300 22395 X E post info effecta se www effecta se 9 UPPDRAG NR RITAD AV HANDLAGGARE EA DATUM ANSVARIG lt SN SN 014 11 26 e NN NN KOMPLETT Ill LIGHT WITH ACCUMULATOR TANK AND SOLAR HEATING SKALA T NUMMER BET V49 05 69 EXPLANATION 1 OUT DOOR SENSOR 2 ROOM SENSOR 3 FLOW SENSOR G7 4 RADIATOR PUMP HOT WATER CIRCUIT 1 5 SHUNT MOTOR HOT WATER CIRCUIT 1 6 LOADING PUMP WITH THERMIC VALVE 7 SENSOR LOAD STOP G6 8 SENSOR LOAD START G5 9 SENSOR START STOP SOLAR EXTERNAL 10 RADIATORS gt e m mmm p a utum Eum e e o XX e x A a iem V e T V o 5 gt x S e o o LL pos z X gt gt gt o e m mmm e a ca Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Effecta AB EFFECTA AB Vastra Ragdalsvagen 21 434 99 kungsbacka Tel 46 300 22320 Fax 46 300 22395 E post info effecta se www effecta se UPPDRAG NR RITAD AV HANDLAGGARE E A 014 11 26 mo up Mun ree E TUNI Ann Md MM MM CIC ML pU SES V CREE DATUM ANSVARIG KOMPLETT Ill LIGHT WITH SEVERAL HEATING CIRCUITS SKALA NUMMER
3. 99 0 1004 08 X OSL 08 X OSL Je1euueip 1 4 o s o s ejnsseJd By 9 2 614 OLE 0921 ww 08r 1619 2201 ww 2201 IIl LL3 1d AO VIVO IVOINHO3L 2 1 ONILNSA t 6 V WOOO V V V NHOI3H V V MOM I IIl NOILVNV m gz S 8 ig 081 0S 1 051 104 0 e Bue Technical specification external storage 005 TELO GL Bao OS ya a 0601 39 B ao 099 028 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 138 YIWWNN NM S S8C 8l 5 TIVNSH3ANI IIl LLJ THAO V LO3333 90 21 10 DINVASNV Wniva 3uvBDY V3 OY LIN YN OWYdddN effecta es e1299egoJur 1sod 3 S6 20 00 0 X 4 06 2c 00 0
4. 2 Introduction 43 Cleaning 2 ocope of delivery 44 Cleaning and service 3 Warranty 45 Service 3 Warranty terms 46 Service 3 System data 47 Adjusting door to ash compartment 4 Contents 48 Troubleshooting 5 In general 49 Documentation of settings 5 Symbols in this document 49 Technical data 6 Your safety 50 Technical specification K3 external feeding 7 Safety components 51 Technical specification K3 internal storage 8 Components 52 Technical specification K3 suction system 9 Fuel 53 Connection suggestions internal hotwater and radiators 10 Boiler room 54 Connection suggestions radiators and heaters 11 Placement of components K3 external feeder 55 Connection suggestions accumulator tank with solar heating 12 Placement of components K3 internal storage 56 Connection suggestions several heating cicuits 13 Placement of components K3 vacuum system 57 Component placement K3 14 Placement of components K3 vacuum system 58 Component placement K3 15 Placement of components K3 internal storage 59 CE 15 Placement of components K3 electrical system 16 Placement of components K3 burner 17 Cleaning system burner 18 Cleaning system boiler 19 Disassembly for move 20 Function suction system 21 Suction system and storage 22 Installation of suction nozzles 22 Installation of hoses 23 Electrical connection 24 Outlets of the circuit board 25 Outlets of the circuit board 26 Electrical S
5. TELO 4 OST ejBue exXoug T 0 6 005 Technical specification suction system n 98170517051 O Lm OSSI OSI 0601 20 Qo e ao 8 c 0n0nanngnnnnanna A UU 1061 e d o 839 W 00 Qo goo e 0911 AE OZE T Org Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta m Connection suggestions internal hot water and radiators HEAT CIRCUIT CES CS fe Peel Me ed 2 mom mum Qu LDR gt rri 2 HHX INCOMING WATER COMPONENTS 1 ROOM OUT DOOR THERMOSTAT 2 RADIATOR VALVE 3 RADIATOR PUMP 4 REFILL 5 SHUNT WITH SHUNTMOTOR 6 MIXING VALVE 7 EXPANSION VESSEL WITH SAFETY VALVE 1 5 BAR 8 DRAIN COCK 9 DIRT FILTER EFFECTA AB V stra R gdalsv gen 21 43496 kungsbacka Tel 0300 22320 Fax 0300 22395 E post info effecta se www effecta se UPPDRAG NR RITAD AV HANDL AGGARE E A DATUM ANSVARIG 012 02 20 PRINCIPAL SCHEME EFFECTA KOMPLETT WITH HOT WAT
6. 9 safety Expansion card G9 Flow sensor shunt group 2 NTC 22 L1 Incoming 230 G10 Flow sensor shunt group 3 NTC 22 kO N Zero G11 Flow sensor energy measuring 1 NTC 22 PE Earth G12 Flow sensor energy measuring 2 NTC 22 kO PE Earth G13 Flow sensor energy measuring NTC 22 N Zero G14 Flow sensor energy measuring 4 NTC 22 kO 19 Radiatorpump shunt group 2 2A 230 VAC G15 Flow sensor loading circuit NTC 22 kO PE Earth G16 N Zero G17 20 Radiatorpump shuntgroup 2A 230 VAC G18 21 Shunt motor group 2 2A 230 VAC G19 N Zero 1 Flowmeter 1 5 22 Shunt motor group 2 2A 230 2 Flowmeter 1 5 23 Shunt motor group 3 230 VAC 3 Flowmeter 1 5 N Zero 4 Flowmeter 1 5 24 Shunt motor group 230 VAC PE Earth 64 Room sensor shunt group 2 1 N Zero 65 Room sensor shunt group 2 2 25 Suction motor 66 Room sensor shunt group 2 3 PE Earth 67 Room sensor shunt group 3 1 N Zero 68 Room sensor shunt group 3 2 26 Safety ball valve 230 69 Room sensor shunt group 3 3 PE Earth 70 Port free N Zero 71 Port free 27 Pump loading circuit 2A 230 VAC 72 Proximity sensor internal Brown PE Earth 73 Proximity sensor internal Black N Zero 74 Proximity sensor internal Blue 28 Additional fan speed controlled 2A 230 VAC 75 Proximity sensor internal White 29 Extra valve 2A 230 VAC 76 Proximity sen
7. Tm COLD 5 e Bue 005 0 1 GL OE U Ut 0002 0601 091 Ov dm Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 138 YAWWNN VIVAS E NM 6 6 81 WALSAS NOILONS III LL3 Td NO 193543 90 21 10 DB VASNV Wn va V3 JuVBDV IGNVH AV QVLIM YN D vu ddn 111 aS RSJ MMM 5 1500 3 S6EZZ 00 0 Xe4 Oc cc 00 0 191 exoeqsBunx 66rEr 12 ese 4 gy vrIO34433 NM 8 11 9 8 9 9 92 81 M Sv M Ort M1 Do OV Do 001 006 1911 901 OVA OEZ O91 Or 101 ed 01 9 291 66 OSL X 091 O S 9 2 092 uu z 1l NM 9 11 9 8 9 NM 98 92 81 M Sr M MI Oe 001 008 4ei 901 WW WW p OVA 088 08 091 07107
8. ___1200 002 When placing the nozzles on the bottom you need to decide how many to place We re commend a distance of 600mm from wall and 1200mm between the nozzles It is possible to place them further apart but it effects the ability to empty the storage completely Sloped wall In a storage with sloped walls we recommed a distance between the nozzles of 1200mm and 600mm from a vertical wall The wall the nozzle is to be mounted on must have a slope of 45 9 1200 600 VEM o 009 Mounting of hoses When mounting the hoses make sure that all connections are tight The hoses must
9. ALIHM Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Effecta AB 1 as L d 4 Fo E L 4 2 2 2 2 25 MOTHER BOARD LAMBDA CARD EXPANSION BOARD HIGH VOLTAGE 230 VAC LOW VOLTAGE POT FREE eo 123 123 LAMBDA CARD OVERHEAT PROTECTION WHITE FALLSHAFT BROWN BLACK Lb RED F GREY BLUE ot TACHO METER 1 1 DOOR SWITCH Use DISPLAY EFFECTA AB I Nid H31N3O H1HV3 133008 H31N3O Menu system OPERATION Fan Feeder settings Temperature set Information Service Installation VER 3 0 Fan boiler Fan lowspeed Fan lowspeed burner Fan lowspeed burner Fan larm Fan larm Support dose Pellets diameter Run start dose Run supp dose Run oper dose Acc high G5 Acc low G6 Stop G5 Start G6 max G1 Loading pump Start Loading pump Stop Igniter hours Oper pellets Clean number Reset info On Off Interval Number clean Clean pause Cleaning conv Flue gas Max time burner Ext contr Fill feeder Effect high speed Effect low speed Testblow start Phase out Fan pre oper Fan low pre oper Flame sensor Quickstart Lambda Lambda 2 Calibration sensor I a HEATING
10. Connection for filling pellets 14 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Placement of components internal storage Hose clamp 2pcs Meltable plastic tube Handle storage lid Gas damper Internal storage Internal feeder Internal feed motor Motherboard Card electrical heater Terminal block N and PE Power supply boiler 20A fuse USB connection for updating software Capacitor underpressure fan Expansion board Lambda board Mechanical overheat protection Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Placement of components burner effecta Ignition console oide Front Top 1 Outer tube 1 Combustion tube 1 Connection compressed air 2 Fallshaft 2 Fallout pellets 2 Connection flame sensor 3 Overheat protection fall shaft 3 Flame sensor hole 3 Power to the burner 4 Combustion fan 4 Hole for ignition element 5 Flame sensor 5 Hole for compressed air 6 1 Blowpipe to the compressor Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta a Cleaning system burner Remember to always cut the power to the boiler before starting
11. OL eyoeqsbuny 66r p 12 gy vIO333 MA S L1 8 8 9 MA 8 11 9 8 9 yeay euin NM 92 92 81 92 52 81 yndyno yesy M Sv uonunsuoo eou1o9 3 M Or v Ort 44618 uonuunsuoo e2u129 3 MI Aqpueys uonunsuoo e2u129 3 Do ut 001 2e 001 Bunegedo xey 008 008 901 1911 901 9185 t p 91846 sseuxyou1 19946 y t epnueuu sseuxpolui JOYS OVA OES OVA 08 08 uono2euuoo e2u129 3 ww 09 Oc I UU 091 02 Keuuiuo ulli ed 01 8 01 8 49JI6q pjoo eap 66 29 81 3EM 99 01 10014 OGI X OSI ww 061 X 051 Jejeuueip jusuyoeye o s 0 2 By SZZ 01 BIE 09 08 1 1 2111 uu 2411 LHOM IIl LILA Td ANOM VIVO IVOINHO3L 2 1 ONINJA 2 4 MOOONIVaG V V H31VM LOH Z V V H31VM LOH MO I IIl LLJ 1d NO9 SNOLLVNY 1dX4 Technical specification internal storage 981 0S1 0S1 0a gm 081 0S1 0S 1 spuemdn 104 OLD
12. 1 hour of run ning in to 6 minutes Measure the pellets and check that it is compatible with the building power demand If you have activated low speed also run and measure it Boiler temperature The bolier temperature is set in the Temperature set menu There are a number of different system that need different settings If the boiler has an internal hot water circuit you set start and stop temperature not to be to cold for hot water production for example start at 72 and stop at 80 If it is a Light you need to set the temperature to the external tank You place the sensor connected to G6 high in tank this is the temperature that starts the burner Sensor G5 is to be placed low in the tank this is the temperature that stops the burner Calculated operational doses of pellets with an energy content of 4 8 kWh kgl Effect kW 12 5 15 17 5 20 22 5 25 27 5 30 32 5 36 Added fuel kg h 2 6 3 1 3 7 4 2 4 7 5 2 5 7 6 25 6 7 7 5 Values Unit Recommended Values measured value CO 1 1 mg m ppm 40 300 Flue gas temperature 140 200 Vacuum in chimney Pa 15 20 Combustion efficiency 90 92 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Tuning the boiler Electrical heater You must choose which effect you want your electrical heater is to use if activated You can choose between 3 6 9 kW 9000W Note
13. 5 Return nozzle Suction to boiler Return from boiler Cover plate Suction nozzle Return nozzle 1 Suction nozzle 3 Connector Hose clamp 4 Hose for return 5 Hose Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 5m Installation of suction nozzles Regardless of the number of nozzles installed there will always be a certain amount of e pellets left in the bottom of the storage The nozzles are designed so that they can be mounted on the bottom of a flat storage or in a storage with a sloped wall It is important that the slope of the wall is 45 so that the mounting plate comes in at the right angle Make sure to seal behind the mounting plate so no dust can leak out When the nozzle is placed on the bottom of the storage it is important that it is bolted firmly due to the pressure it has to take when the storage is filled with pellets 7 Flat hottom 600 009
14. 8 JepeeJ 907 907 907 Z VIP JOLOW 20129 201479 01 9 9 1 1 JOJOW 280 280 280 L ll Josues 5 2299 2299 2299 JOJO 1801 1801 1801 L VL egoud opquup SLL SLL SLL 4 L tl sob 8801 8801 8801 62 92 0 MASE MASZ MAOZ NOILdlal2S3d 1 1 1onaosd 1a vd 69 0 08 138 YIWWNN VIVAS TAGOW NO SNIGN3d3G 5312119 DNIAHVA VL23333 SLNANOdWOD 50 40 6810 DINVASNV WNLVG 3uV5DV 10NYH OY LIN UN DYYAddN 9s e199jJ9 WWW 9s e129egoJur1sod 3 96222 0020 XP 02 202 00 0 19 eyoeqsbuny 12 enseA eaga V1O3433 EL Zl LI 01 i 10950 Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Effecta AB E Component placement TAGOW NO S312IL8V ONIAYVA VL23333 SLN3NOdWOD DIBVASNV S0 Z0 S10 Wniva 3uVDDV IONVH v3 AV QV LIJ YN 9 79099 9s e129 J9 WWM 5 1 1500 4 S6EZZ 00 0 X 4 OCECC 00 0 OL eyoeqsbuny 12 gy v1O3433 aya L 1 1
15. EN 61 000 3 3 1995 A1 2001 A2 2005 SPCR 028 Approval testing of welders fusion welding Heating boilers for solid fuels Metallic products type of inspection documents EMF Emission Immunity Safety of households for storage water heaters For gas oil and solid fuel burning appliances having electrical connections Harmonics equipment with rated current lt 16A phase Voltage fluctuations equipment with rated current lt 16A phase Kungsbacka 2014 04 20 hh Erik Andersson CEO Effecta Energy Solutions AB
16. El step A B C Fuse A El heater 6 kW El heater 3 kW Weekday Clock Calibrate sensors Function test Alarm Language Start guide Selection of shunt group Selection of shunt group Selection of shunt group Settings for the electrical heater Option of control Settings of the room temperature Temp to radiator underfloor heating Activates radiator pump Maximum allowed temperature to the flow Minimum allowed flow temp Maximum allowed room temp Minimum allowed room temp Shunt opens full at set temp Outdoor temp when heating turns off Rad pump is runned 1min 2hours Outdoor temperature at the outdoor sensor The heating curve for the heating control pg 36 38 Option of slope to the heat curve pg 36 38 Option of adjustment to the heat curve pg 36 38 Options for energy saver Options for DHW Priority Option of control Flow temperature Activates radiator pump Selection of system Options for energy saver Options for DHW Priority Weekly Schedule when the indoor temperature is lowered by a number of degrees Example At 06 returns to normal temperature and to be lowered again at 22 Example At 06 returns to normal lowered at12 and at 16 returns to normal again and lowered at 22 Temperature when shunt closes to priority hot water Maximum allowed temperature to the flow Choose between different effects on the electrical heater 1 phase is maximum 3kW Enter the house s main fuse Log
17. Loosen the bolts to the lid If the boiler has a suction sys Unscrew the 3 bolts holding Remember to disconnect all tem disconnect the safety ball the storage and remove it the cables to the suction sys valve Loosen the hose clamp tem before you remove the lid the fall shaft Loosen the 2 nuts which holds the safety ball valve to the storage and remove it all If there is an internal storage just remove the hose Disconnect all the cables to the burner Then unscrew the 4 bolts which holds the burner plate to the boiler Remove the burner straight out Make sure when you reassemble the storage that all hose clamps and other sealings are tight Leakage will e cause disruptions due to there being no underpressure Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 19 5 Function suction system If the boiler is equipped with a suction 4 system the menu on the right is shown Night blockage Yes In the INSTALLATION menu you need to Hl storage no amp change settings in order to customize the system for your energy needs j 5 Function The suction system includes a number of Consumption 2 O important components On the storage kW h kW day Time filling h there is a suction motor which builds up a 5 120 30 underpressure in the hose connected to the 10 240 15 filling outlet of the storage The proximity 15 360 10 sensor senses the need for filling
18. SYSTEM Shunt group 1 Shunt group 2 Shunt group 3 El heater Room temp 20 0 18 2 C Flow temp Radiator pump Max flow temp Min flow temp Max room temp Min room temp Heating off Outdoor temp Heat curve Slope Adjustment Energysaver DHW Priority Flow temp 18 2 C 10 Flow temp Radiator pump Max flow Min flow Max room temp Min room temp Power outlet A El heater 6 kW El heater 3 kW FanPulse 2 FanPulse 3 Fan start Oper Phase start Burner starts Igniter hours Oper pellet Ign sequence 1 Ign sequence 2 Ign sequence 3 Level oper Time oper Time phase out Temp down effecta Flue temp Flow temp Boiler temp CO2 Flame sens El heater Igniter Calib sensors Function test Alarms English Start guide V V V VM aa Sensor G2 Sensor G3 Sensor G4 Sensor G5 Sensor G6 Sensor G8 Sensor G8 Outdoor Indoor Feeder Fan Compressor Solenoid valve Test air cleaning Convection clean Shunt motor G Electrical heater Radiator pump Loading pump Flue gas fan Start phase failure Oper phase failure Max flow temp Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Menu system Flue gas temp Flow temp Boiler temp CO2 Flame sensor El heater lgniter Operation Heating system Other Burner Fan Fee
19. any work on it e Function On the side of the burner there is a compressor with a compressed air hose mounted which cleans the burner Compressed air is blown into the burner When the cleaning starts the com pressor builds up a pressure in the hose which then is released with a pressure shock and the ashes are removed from the burner You can set how often how long and during which times cleaning is allowed in the SERVICE menu Compressor The compressor builds up a pressure in the air hose The compressor has a life span of about 2500h and can then drop in pressure head or leak air Then there is a renovation set to renovate the compressor Compressed air hose The hose is only used to store air before it is released into the burner Pressure gauge ohows the pressure in the hose It is also an indicator when or if you need to adjust the pressure for optimisation Pressure switch otops the compressor when targeted pressure is reached there is a adjustment screw which is preset on 7 bar Compressor Capacitor Pressure switch Pressure gauge oolenoid valve gt Compressed air hose Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Cleaning system boiler Remember to always cut the power to the boiler before starting any e work on it Function On the boiler there is an magnet motor which does the mai
20. at the same time as the turbulators Do not forget the area below the boilers fan as there can be fly ash from the combustion 9 The fan Clean the fan twice a year Remove the 4 wingnuts 1 located on the mounting plate Lift fan and clean the wings 2 from dust and soot If the fan is not cleaned it will result in the boiler having slower heating and poor combustion Flue attachment Clean the connection to the chimney twice a year In time these will gather fly ash Loosen the 2 wingnuts which holds the lid on the angle Scrape or use suction to remove ash Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Service Don t tap the lamba against something in order to get it clean e Use a brush Lambda The Lambda needs to be cleaned once a year Unscrew it from the flue tube Brush it clean and make sure that the holes on the top are clean Outer tube After a period of heating up there will be dust and ash from the burner s inner and outer tube It must be removed to avoid deterioration in combustion and function We recommend that the cleaning is done after about 9 tonnes of pellets consumption After the cover is removed start by loosening the four wing nuts 1 wich are holding the burner in place and then unload according to description Then pull out the inner combustion tube 2 and clean from ash and
21. of runtimes of the different electrical heating steps Weekday settings Clock settings Options calibrate sensors Test mode of the products different functions Alarm log Choice of system language Initiates the Start guide Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Menu system Function Flame sensor Igniter Feeder Fan Compressor Solenoid valve Test air clean Convection cleaning Shunt motor El heater Radiator pump Loading pump Boiler fan Shunt motor 2 Radiator pump 2 Shunt motor 3 Radiator pump 3 Fill storage Function test of the flame sensor Must be illuminated to test function Activates ignitor the fan starts at 60 to protect the ignitor Activates the auger feeder Activates the fan Activates compressor for cleaning Activates opens solenoid valve for cleaning Activates and tests the full AERO cleaning cycle Activates the cleaning of the convection Activates the shunt motor open or close Activates electrical heater Activates the radiator pump Activates the loading pump for another unit such as Laddomat Activates and tests boiler fan Activates the shunt motor 2 Activates the radiator pump 2 Activates the shunt motor 3 Activates the radiator pump 3 Activates suction system R27 R28 VridM Ignition failure Start phase failure Oper phase failure Number of failed ignitions Number of Start
22. pellets 20 480 g when set time between fillings is reached 25 600 6 the safety ball valve closes and the suction system is allowed to start with a delay of 60sec The suction motor tries to fill the storage by running for 15min resting for 15min running for 15min and so on If the storage hasn t been filled after 80mins the boiler alarms Suction time A filling normally takes 15 20min suction time Time hetween fillings How often your system chooses to fill is down to your settings in the menu We recommend you set it as far a part you can but with a margin so that the storage never is empty A full storage contains roughly 200kWh of energy If your house consumes 8kWh the storage last for about 24hours Night blocking If the boiler is placed so you can hear it you can block refilling of pellets certain times of the day In the SERVICE menu you can set when refilling is allowed On and when its not allowed OfD Then refilling isn t allowed between these hours unless there is a risk of downtime of the burner in which case the filling cycle runs even though you have turned it off Fill storage If you activate Fill Storage the storage will be filled regardless of settings This function is used when you first start the system or if the storage is empty Note that if the storage has been emptied the feeder must be filled again In the Installation menu you find the function Fill feeder The boiler must be in
23. phase failure Number of Operation phase failure Alarm at disruption Alarm There has been a problem during operation phase The most likely problem is that the pellets have Burner run out The flame sensor can also be covered by soot Alarm The burner has missed the ignition phase The most likely problem is a poorly adjusted starting dose Ignition Also check the ignitor in the function test Alarm The flue gas temperature has been above 320 C This is an extremely high temperature please Flue gas check that the automatic cleaning is working function test and that the boiler is clean Also check the flue gas sensor Contact installer Alarm The temperature of the boiler has been above its max value Normally this can happen from Boiler temp the heat after the combustion cycle Try to lower the stopping temperature if the problem reoccurs Alarm Alarm from the Tachometer on the burner fan check for faults on the fan m USB connection Dont interrupt the download This will damage all software in the boiler Make sure that your USB stick contains the correct files There should be an hex and bin file on the USB stick In order to upgrade the software in the boiler you need to connect a USB memory to the boiler There is an connection cable located behind the cover plate Turn off the power to the boiler Insert the USB memory then turn the power back on The controller starts downloading the new
24. soot It is important that the holes are not clogged with ash as these are essential to good combustion Then clean the outer tube 3 from the ash and pellet residues Reassemble in reverse order Changing and or servicing the flame sensor Remove the contact to the flame sensor by pulling straight back 1 The outer nut of the flame sensor is loosened completely 2 Pull the flame sensor with nut and clamp bushing out of the container If you are going to replace the flame sensor move the nut and clamp bushing to the new sensor The clamp bushing is to be pushed fully back against the shrink tubing Mount the flame sensor in the container ocrew the nut by hand so that the sensor is tight but not overly Mount the flame sensors contact 1 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 45 46 m Service Internal feeder Remove cover plates Unscrew the 4 bolts which hold the motor in place 1 Pull the motor and spiral down diagonally 2 Use a vacuum cleaner to remove the dust If there is packed dust the spiral and motor needs to be separated Unscrew the bolt located on the shaft C3 Safety hall valve and angle If service or cleaning need to be done in the fallout bend that is located before the safety ball valve loosen the 2 nuts 1 which holds the bend in place Then loosen the hose clamp which holds the plastic hose to the ball valv
25. storage Flame sensor Level start Level oper Time oper Time phase out Snabbstart Temp down Temp down Lambda co2 level Calibrate FanPulse 1 FanPulse 2 FanPulse 3 Fan start Oper start Burner starts Igniter hours Oper pellets Number clean Ign Sequence 1 Ign Sequence 2 Ign Sequence 3 Option if cleaning should be done prior to or after the running cycle Time when AERO cleaning is allowed ON Time when AERO cleaning is not allowed OFP Setting of how many cleaning cycles Setting of the amount of blows in each cycle Time between each blow in a cleaning cycle Settings for cleaning the convection Temperature for the cleaning to start Max operation time of the burner before pause with AERO cleaning Choice of external START STOP control to the boiler Advanced settings requires password Activates feeder for 15min Only in mode Burner Off Setting for the burners effect in high speed Setting for the burners effect in low speed Seconds the fan blows before ignition phase Seconds the ignitor is active after the flame sensor has approved start value The fan speed before operation phase The fan low speed before operation phase Time that the fan afterblows before standby or cleaning To flame sensor menu To quick start menu To Lambda menu Time between fillings Time when filling is not allowed Manually filling of the storage Set value where the burner goes fro
26. temperature in each room you may have to adjust each radia tor separately When you choose more than one shunt group each one must be adjusted with the included room sensors More info about the shunt control is on pg 36 38 Energy saver In the shunt control there is also a possibility to lower the temperature certain time of the day or some days in the week Suction system If the boiler has a suction system you need to set the time when it is allowed not allowed to retrieve pellets from the storage You find the settings on pg 20 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Hot water Hot water is produced in a copper coil There are ribbed flanges on the outside on the coil for best heat absorption The cold incoming water is mixed with the heated water from the coil in the mixing valve 1 The mixing valve includes a thermostat where you set the temperature on the outgoing water If you don t run the boiler with pellets there also is a possibility to heat the hot water with the electrical heater which should be set to 70 for good hot water comfort If the operating temperature of the burner or electrical heater is too low the coil will not deliver the quantity of hot water as desired for larger amounts When hot water is prepared in a coil legionella bacteria cannot occur m Valve combination The combination valve is there so the hot water temperature cannot scald I
27. work You must submit your complaint without delay You must always state the type of product the date of purchase and the serial number Otherwise the heating and plumbing industry s current regulations apply in case of complaints Guarantee terms The guarantee is valid on condition that The boiler and the heating system have been installed in accordance with the installation instructions and in a professional manner The location where the product is installed is suitable for purpose The guarantee does not cover The overall function of the heating system costs incurred as a result of the heating system being out of operation or the cost of the temporary replacement of products Damage or injury caused by negligence during the installation or by operating the boiler in a way which conflicts with the installation and user instructions Damage caused by abnormal wear incorrect operation and maintenance Damage caused by the use of non original spare parts Damage caused by the boiler being positioned in an unsuitable location Damage caused by vermin The terms may be different from country to country Check with your installer System data Installer Date Electrical installer Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Contents
28. 40 30 20 Slope The heating curve chosen the software is the temperature to the flow at 15 C outdoor temperature Therefore the flow temperature will change with the outdoor temperature 30 Adjustment 25 20 15 10 b 0 5 10 15 20 25 Outdoor temperature When a adjustment of 5 C is done the heating curve is adjusted at all outdoor temperature with 5 Slope 50 C adjustment 5 Slope 50 C with no adjustment 30 25 20 15 10 b 0 5 10 15 20 25 Outdoor temperature If it is cold outdoors cold winter and the room temperature is too low Increase the slope by 1 2 C If it is cold outdoors cold winte and the room temperature is too high Decrease the slope by 1 2 If it is warm outdoors average autumn spring and the indoor temperature is too low Increase the adjustment by 1 2 C If it is warm outdoors average autumn spring and the indoor temperature is too high Decrease the adjustment by 1 2 C Wait at least 24 hours between adjustments and changes due to slow response of heating Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Mounting and adjusting of the draft stabiliser A draft stabiliser makes sure that a constant and stable draft is achieved Also condensation in the chimney
29. BET V49 05 65 EXPLANATION 1 HOT WATER CIRCUIT 1 2 HOT WATER CIRCUIT 2 3 HOT WATER CIRCUIT 3 4 FLOW SENSOR 1 G7 MOTHER BOARD 5 FLOW SENSOR 2 G9 EXPANSION BOARD 6 FLOW SENSOR3 G10 EXPANSION BOARD 7 SENSOR CYLINDER ONLY IN HOT WATER CIRCUIT 2 8 RADIATOR PUMP 1 RADIATOR PUMP 2 10 RADIATOR PUMP 3 11 SHUNT MOTOR 1 12 SHUNT MOTOR 2 13 SHUNT MOTOR 3 14 OUT DOOR SENSOR 15 ROOM SENSOR o A e o gt e e ET o 5 f e o gt gt o e e 1 e e c Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Component placement L L L eqni Ajejos 7200 7200 7200 El L Ul Oley 0611 0611 0611 el 1782 1782 1782 L L L jeuunq UOHOJNSUI e 024 oZz Ol L L L JOSS JdWO D OLLI OLLI OLLI L L L 1 920 920 920
30. EFFECTA KOMPLETT III 20 25 35 kW INSTALLING MAINTENANCE SERVICE ASSEMBLY effecta Rev JG 015 02 12 5m Introduction We at Effecta would like to thank you for putting your trust in us when choosing your new boiler The Effecta Komplett Ill has been developed to give you maximum performance comfort and quality In order to get the best results from your boiler we suggest that you follow the recommendations in this installation guide Checking your delivery Check that the boiler has not been damaged during transportation If the boiler has been damaged you must report this to the transportation company immediately Your safety If you discover any faults or defects in our products it is important that you report them as quickly as possible to your installation engineer so that the fault can be rectified Make sure that there are no flammable materials close to the boiler to help prevent risk of fire You must use your own judgement when operating the pellet boiler Remember that the hatches and some surfaces can get hot You must take care to avoid being burnt The user It is the user s responsibility to operate the boiler according to our instructions If you do not operate and maintain your boiler correctly the environmental impact of the boiler will be greater its efficency will be reduced and the service life of some components will be shorter If there is anything that you are not sure about please conta
31. ER CURCUIT AND RADIATOR SKALA NUMMER BET V50 05 79 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Connection suggestions radiators and heaters HHX KV PS V Z wy ZA R rllllll EFFECTA AB E j V stra R gdalsv gen 21 434 99 kungsbacka Tel 46 300 22320 Fax 46 300 22395 E post info effecta se www effecta se UPPDRAG NR RITAD AV HANDLAGGARE E A DATUM ANSVARIG 014 11 26 KOMPLETT Ill LIGHT SKALA NUMMER BET V49 05 68 EXPLANATION 1 2 3 4 5 6 7 8 9 1 OUT DOOR SENSOR ROOM SENSOR RADIATOR PUMP 1 MOTHERBOARD FLOW SENSOR 1 G7 MOTHERBOARD SHUNT MOTOR MOTHERBOARD SHUNT MOTOR EXPANSIONBOARD RADIATOR PUMP 2 EXPANSIONBOARD FLOW SENSOR G9 EXPANSIONBOARD WATER HEATER WITH LOADING CIRCUIT 0 RADIATOR CIRCUIT IAN Hk Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se
32. LECTRICAL HEATER 34 343 KW CIRCUIT DIAGRAM EFFECTA KOMPLETT DAT 014 02 06 HOJVIQvH 116 OLN 0 LZ 69 Q S 89 LIN YOLOW LNAHS ec HOSN3S HOLOIN LNDHS X N I ve 3d HOLONN NOLLOnS gt N SC 3d 99 Q 9 9 796 HOSN3S WOOU 65 015 MO YOLOW TIV8 AL34VS LLS ONIUNSVAW AOU3N3 9c dd Q3T1OH1NOO Wd N 10 3d did ONIGVOT 2 N 8 3d QHT10H1NOO Wd VHLX3 HN 6 3d 219 ONIUNSVAW AOU3N3 15 ONIENSVAW ADH3N3 VIO LONINNSVAW ADYANA 819 919 119 819 619 QS RQ nS MQ em eq eS INQ INQ WS Q S S S o N ONIYNSVAW AOU3N3 YOLVINWNOOV HOLOIN H3XIIN og qad 28 MOV I8 YOLOW YALINDI 4303434
33. LIZZI LIZZI LIZZI 9 169108 169108 169108 Gl ULL uoisubdx3 69 LOE 69 LOE 69 LOE yl 9 9 9 SIOLO NCUN 920 920 920 l UI Jojow 20195 20195 20195 Zl 1095 uooils C494 C19 191 UOHOJNSUI LIZZ LIZZ LIZZ 01 211 sqouy 86 86 86 6 06 108 06 108 06 108 8 171 JOJOSUBPUOD 105 10801 10801 10801 Z 2701 2701 2701 9 LUV JOUJOW 1102 1102 1102 G 1 4 09449913 64105 6410 6410 y ysy 718 718 718 JOOP 450 uouoinsu 124 TA IZZ JOOP USD 10 0 9 9 9 GE SZ 0Z MASE MASZ MAOZ 1 1 1 1a Vd 6S 70 0S 138 YSWWAN VIVIS l Gl 9 70086 1099905 o o 000 9o w di Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se effect F rs krar under eget ansvar att produkten F rs kran om verensst mmelse Declaration of confirmity Konformitatserklarung D claration de conformit Declare under our sole responsibility that the product Erkl ren in alleiniger Verantworten daB das Produkt D clare sous sa seule responsabilit que les mod les Pellet gasification hoiler Effec
34. al according to Effectas directions and current legislations Controls and tuning of the product should be made by a professional A chimney sweeper should also be contacted when commisioning the product The electrical connections must be done by a qualified electrician according to Effectas instructions in this manual The casing outside of the burner must always be fitted on the boiler when the boiler is connected to the electrical power Before cleaning and maintenance of the product make sure it is disconnected from the main power It is strictly forbidden to open any doors when the burner is igniting If any door or hatch is opened when the burner is running great caution must be taken Any kind of interference or use of anything other than original spare parts can result in damage to the product or person It also removes Effecta from any liability It is strictly forbidden to make any changes or alterations to the boiler without prior approval from Effecta If any changes are made the safety functions or any other function might not work as it is supposed to and all warranties and liabilites from Effecta are cancelled This manual should be kept during the whole life span of the product Any updates will be reported on the Effecta web page www effecta se Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Safety components Drop tube Between the storage and the feeder there is a m
35. amd 3ATVA GION3IOS IVNH3DG LIA H313AOHO VLL SE ama 99 OV I HOSS3HdOO zi Eg t 99 19 HOSN3S ONINV319 1 gt Te 4 HOSN3S 89 RO e 2 yl 1 oO ge P di dn 1 i I 1 xil e a eT 5 boo jz 1 5 20 5 8 54 2 l oo e 2 2 lt o E e 5 5 H m g T c m Emm e lt Q 4 e 2 I 5 5 gt lt O 2 x e B mmm FE e Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se SWITCH SAFETY MOTOR 6 19 Q 8 Q 09 Q LLO 69 5 919 199 9 5 7 ania S E S 5 D S x o c o S 5 e D S 2 Tel 0300 22320 Fax 0300 22395 E post info effecta se www effecta se dd dd dd HOLVIGVY N 6l dd oQ r AAE 5vIa 1 680 jez Q 21 Q mos lt J HOSNSS ALIAIXOtd RITAD AV Erik Andersson 50 12 11 NUMMER E
36. ant that the chimney is tested and approved by a HETAS approved installer before a new boiler is installed If the chimney is tall and has a lot of mass to heat up there is a risk of condensation Measure the temperature 1m down from the top when the burner is running the temperature should be 70 C Read more about the chimney on pg 42 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Placement of components K3 external feeder Front Back Top Adjustable feet Drain cock Flue gas measuring point Ash door Return hot water circuit Boiler fan Door switch Flow hot water circuit Cleaning access Front cover Hoses electrical wiring Flue connection Handle Front cover Display Shunt valve Conduit for sensor Draft stabiliser Fall shaft pellet burner Connector feed motor auger Not on Light Protective cover Mixing valve for hot water Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Placement of components internal storage Front Back Top Adjustable feet Drain cock Flue gas measuring point Ash door Return hot water circuit Boiler fan Handle ash door Flow hot water circuit Cleaning access Front cover Hoses electrical wi
37. chematic 27 Electrical Schematic 28 The menu system 29 The menu system 30 The menu system 31 The menu system 32 The menu system 32 Alarms 32 Update software 33 Tuning the boiler 34 Tuning the boiler 35 Hot water 35 Valve combination 36 Shunt control 37 Tuning the boiler 38 Examples of curves 39 Mounting draft regulator 40 Overheated fallshaft 40 Replacing the combustion fan 41 Replacing the igniter 42 The chimney 42 Flue attachment Effecta AB V stra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se E general The hoiler Effecta Komplett Ill is a boiler which is to be fueled with wood pellets No other kind of fuel is allowed not logs or oil Disassembly and disposal It will be many years before your Effecta boiler is worn out but it is important that you follow the regulations in force at the time concerning disassembly and disposal of your boiler The fuel The boiler should burn 6 mm e pellets which come either in sacks or are supplied by bulk truck If you have built a bulk storage you should follow the current recommendations to ensure that the quality of the pellets does not deteriorate Never use pellets which do not meet European pellet standards DIN as this may result in problems in operating the burner Symbols in this document Information This symbol is shown with to indicate important information the installer should know and e understand Neglecting
38. ct your installation engineer or Effecta for advice Warranty The warranty takes effect from the date on which the boiler is installed The supplied installation form must be completed and returned to Effecta You can find the other guarantee terms on page 3 Scope of delivery Please check all components delivered The standard delivery as follows Effecta Komplett IIl boiler Cleaning handle with brush Rake with scraper Flue attachment Draft stabiliser Turbulators 8pcs mounted Drain cock Shunt valve motorized shunt control not in Light version Electrical heater 3 9 mounted not in Light version Thermostatic mixer valve not in Light version Room thermostat optional in Light version Outdoor sensor optional in Light version Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Warranty Effecta products are guaranteed to be free of defects in materials The main body has a 5 year warranty against leakage of water and all other parts have a 2 year warranty The warranty also covers original spare parts Any faulty products will be replaced or repaired at the discretion of the retailer or Effecta If a faulty product is detected Effecta is entitled to replace it with a new or reconditioned product of the same or a similar type If you have a complaint you must contact your retailer before starting any servicing
39. d Convection clean does not clean Increase the number of cleanings The motor does not lift turbulators Increase in the Service menu Check function The burner tube does not get clean Low pressure from compressor The compressor leaks The compressor is not activated Check air pressure min 6bar Seals need to be replaced Activate in the Service menu The feeder does not feed pellets No underpressure Feeder broken Feeder filled with dust Overheat protection fallshaft tripped Check underpressure switch Check seals hoses Check the draft in the chimney Replace motor Check and clean the feeder Clean the boiler and burner Reset overheat protection A sensor shows wrong temperature The suction system does not fill the storage Sensor broken Calibrate System not activated Proximity sensor incorrectly set Replace sensor Calibrate in the Other menu Activate in the Installation menu Check and adjust sensor The suction system is running but no pellets comes through the hoses Connection hoses loose No pellets near a suction point The seal to the internal storage is loose Safety ball valve is open Missing screws on the storage Check for leaks Check the pellet level in the storage Check the seal Check function Check that all screws is in place Effecta AB Vastra Ragdalsvagen 21 434 99 Kun
40. der Temperature set Information Service Installation Fan burner Fan boiler Fan lowspeed Fan burner lowspeed Fan boiler lowspeed Fan larm Tacho Fan larm 55 Feeder Start dose Support dose Pellets diameter Run start dose Run supp dose Run oper dose Temperature set Boiler temp G1 Stop otart Acc tank high G6 Acc tank low G5 otop G5 Max G6 Start G1 Loading pump Start Loading pump Stop Number starts Igniter hours Oper pellets Clean number Reset info Current temperature of the flue gases G2 Current temperature of the flow G7 Current boiler temperature G1 Current CO2 value Current strength of flame in boiler Current effect of the el heater in the boiler Current burner mode Settings for burner Settings for heating systems Settings for other functions Burner mode on off Settings for the fan of the burner Settings of the augers feeding control password needed Settings for the burners operation temp Operations log of the burner Menu for burner service settings Settings for automatic cleaning etc Setting of the burner fan in operation mode Setting of the boiler fan in lowspeed Activating low speed On Off oettings of burner fan in lowspeed oettings of boiler fan in lowspeed Activates Tacho mode Time before alarm triggers Start dose size measured according to pg 33 oize of support dose dose is given between ignition and running mode oize of
41. door temperature must not be higher than 5 C Energy saver function must be switched off Valves on the radiators must be fully open Radiators must be checked and in function It is normal that during the first heating season changes must be done several times in order to find the right setting for the house If you do not know at all what temperatures your house needs you can use our recommended values Houses with underfloor heating in concrete Slope 35 Well insulated low energy house with low temp radiators Slope 40 factory settings A high temp radiator system in a older house with poor insulation Slope 55 Example of curve If the slope is set to 50 this is the temperature sent to the flow at an outdoor temperature of 15 C If the house has underfloor heating the temperature on the curve is set significantly lower Example of adjustment Adjustement of the curve means that you can raise or lower the indoor temperature at a certain outdoor temperature Curve adjustement means that the flow is 20 C when the outdoor temperature is 20 A curve adjustement of 5 means that the temperature is 15 C Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Example of curves Too low a heating curve will result in the house not having the correct indoor e temperature Temperature flow Temperature flow 80 70 60 50 40 30 20 80 70 60 50
42. e 2 The bend is now free and can be cleaned Make sure that there is no packed dust at the top of the feed beam When reassembling ensure the hose clamp is tight Internal storage To clean the internal storage do as follows Remove the insulated cover plate 1 Unscrew the 10 bolts which holds the lid to the storage 2 Clean the grate under the suction motor C3 if the grid gets clogged the suction deteriorates The proximity sensor is wiped carefully so no dust is sitting on the sensor 4 Clean the storage from dust etc Be extra careful at the inlet to the feeder 5 When reassembling make sure all sealing and bolts are tight If the storage is not tight there will be no underpressure and no pellets will feed through effecta Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Adjusting door to ash compartment There are several ways to adjust the door In the picture below you see the hinge to the door to the ash compartment After some time of use some adjustments may have to be done in order to ensure the door seals correctly 1 Depth adjustment If the seal is not tight on the hinge side loosen the 2 bolts that holds the hinge to the frame Loosen the bolts about two turns then adjust the door inward to tighten the door and reverse to loosen the pressure on the sealing 2 Vertical adjustment In order to centre the sealing
43. e feeder is ighited and combusted which heats up the water in the boiler Turbulators Within the tubes in the heat exchanger hang the turbulators The turbulators function eco is to transfer heat from the flue gas to boiler water They must always be placed in the boiler If the flue gas temperature in the chimney is too low the turbulators can be cut off to increase the temperature Draft stahiliser The draft stabiliser gives the boiler stabile draft conditions this improves combustion and efficiency Hot water coil Within the boiler is a hot water coil that heats up the water for the house The water you can drain from the boiler depends on the boiler temperature the mount of flow you through and which effect the boiler is set to We recommend a flow of 12 42l min in the taps In the Light model there is no coil here you heat your water in a external water heater The sealings The seals on the hatches must be checked every year If the hatches do not seal properly the efficiency and the combustion process of the boiler will deteriorate Dust and ash can also leak out during cleaning Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 5 The fuel Wood pellets are made of sawdust a byproduct from handling wood Wood contains lignin that makes the pellet hard without any glue or other binder being used There are several different kinds of pel
44. ed 91 8 28 091 X OSL 0 BY OLE 2311 jndino e y jndino e y uoneJedo uonuunsuoo je2u199 3 es uonunsuoo e9u1o9 3 Kqpueis uonuunsuoo e2u199 3 xew 5 19946 epnueui sseuxolu 12946 uonoeuuoo e2u19e 3 49 IOq Yeip pepueuuuiooeH jueuiuoeqe any 20 01 1004 Jejeuueip ejnsseud 1uDieH SZ LHOM Ill LLJ THAO VIVO WOINHOSL 669 2 1 7 0 1 MOOO amp V V H31VM LOH 4 V V H31VM LOH MOTH I Ill LLAIdWOY SNOILYNY 5 d SSS St 081 0S1 0S1 Bununouu 104 TELO
45. eltable plastic tube which is destroyed when it is overheated The overheat protection on the fall shaft This stops the feeding and the fire damper if the fan temperatures gets too high Reset is made manually The cover must always be in place when connected to main power It only cuts the power to the auger and fire damper Safety lock If the boiler is equiped with suction system there is a fire damper mounted This is closed during filling overheating or loss of power Flame sensor The flame sensor monitors the flame in the burner If a valid value is lost for more than 120sec the feeder stops The burner is cooled down with maximum rpm of the fan for OO minutes before stopping The pellets suction is not allowed to start if the flame sensor detects light verheat protection on the hoiler There is overheat protection on the boiler which cuts the power to both the boiler and the burner if the temperature in the boiler exceeds 95 C Compressed air cleaning On the cleaning to the burner there are two safety systems The controller limits the the time the compressor is allowed to run there is also a pressure switch which closes the compressor when preinstalled pressure is reached Flue gas fan A flue gas fan is mounted on the flue tube The fan helps to maintain a stable underpressure in the boiler and prevents back heat but also improves the com bustion More on the fans adjustement
46. er 3 tonnes of pellets consumption gt gt a dC un 3 Convection part after 3 tonnes of pellets 0 consumption A Qs gt Without automatic cleaning every other week in GUB n winter 4 Ash box as necessary B D Fan after 9 tonnes of pellets consumption 6 Flue attachment after 3 tonnes of pellets consumption 1 Cleaning the ash compartment Cleaning the ash compartment is done through the ash door on the front The easiest way is to use some type of ash cleaner If you do not have access to an ash cleaner remove the ash with a scrape and keep it in a fireproof bin Remember that ashes can contain hot particles for a long time and may not be stored near flammable materials effecta 9 2 Cleaning the burner tube Remove the ash contained in the burner tube this is done either through the ash compartment with the supplied scraper or by taking the burner tubes apart outside the boiler which sometimes can be the easiest way Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se E Service and cleaning 3 The tuhes After 3 4 tonnes of pellets consumption you need to clean the tubes Start by removing the cover plate on top of the boiler Unscrew the plastic knobs and remove the lid Lift the turbulators out of the tubes Use the included brush to clean the tubes 4 Ash hox Clean the ash box
47. er out Warmwasser Eau Chaude ECS Komplett III Light 5 Avluftning Venting Entl ftung Ventilation 49 148 VIVAS NM 92 92 8 39VuOLS TIVNH3 LX3 III LE3 13I AOM VLO3333 G0 2 1 7 LO DINVASNY Wniva V3 3uvBDv IGNVH AV OV LI YN D Yudddn 95 212 1500 4 96200 0020 94 OZEZZ 00 0 1191 exoeqsDun 6 z enseA 055 C69 l 0911 Hv NM S 11 8 8 9 MA S L1 8 8 amp 9 yeay NM 86 66 81 NM 92 92 81 yeay euurxejA M Sv M Sv uonunsuoo M Orr Ort 0215 uonuinsuoo e2u199 3 MI Aqpueijs uonunsuoo 4 ul 001 Do 001 xey 008 008 191 901 491 901 t t 91816 sseuxoiu1 19946 y y puew 12946 OVA OES OVA 088 08 uonoeuuoo 09 71 02 09 Or VOCI eeje Aouuiuo 01 8 ed 01 8 29111 66 81
48. erature you can mount insert tubes on the turbulators or add insulation to the chimney These suggestions increase the flue gas temperature without changing the effiency of the boiler The draft stabiliser vents the chimney from some condensation but it can not fix large quantities Dimension chimney Round Rectangular Komplett 20 kW o 120 mm 100x100 mm Komplett 25 kW 140 mm 120x120 mm Komplett 35 kW 160 mm 140x140 mm m Flue attachment You can mount the included flue attachment in any of the holes on the boilers flue tube Option 1 place the flue attachment on the hole on top of the flube tube and direct it to wanted direction In option 2 you place the flue attachment in any of the three holes around the flue adaptor di rect it in any direction but not downwards Option 3 is for chimneys placed directly over the flue tube this has to be specially ordered Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se A Cut the power to the boiler before starting the service We recommend good service clean of the burner and boiler 2 3 times a year Do as follows for the best result and minimizing the chances for downtime uu 46 5 Sweeping interval 1 Ash compartment as necessary or at about 3 4 tonnes of pellets consumption 7H lh 2 Burner tubes aft
49. ety Mother board G1 Temp sensor boiler NTC 22 kO PE Farth G2 oensor flue gas PT1000 N Zero G3 Extern control L1 Incoming phase 6 3 A 230 VAC G4 Tacho meter PE Earth G5 Sensor accumulator tank low NTC 22 kQ N Zero G6 Sensor accumulator tank high NTC 22 kO 11 Radiator pump 2A 230 VAC G7 Flow sensor NTC 22 12 Shunt motor 2A 230 VAC G8 Flame sensor N Zero 1U Connection to display board 13 Shunt motor 24 230 VAC 2U Connection to electricity board PE Earth N Zero 1 Outdoor sensor 14 Solenoid valve AERO 2A 230 VAC 2 Outdoor sensor PE Earth 3 Room sensor shunt group 1 N Zero 4 Room sensor shunt group 2 15 Compressor 2A 230 VAC 5 Room sensor shunt group 3 PE Earth N Zero 52 16 Magnet motor 2A 230 VAC 53 Tachometer N Zero 54 Tachometer 17 Loading pump 2 230 55 Amperemeter N Zero 56 Amperemeter 18 Alarm 230 VAC 57 Amperemeter 19 Alarm closed on larm 58 Joint 20 Alarm closed on larm Lambda board 1 Lambda White 2 Lambda Brown 3 Lambda Black 4 Lambda Red 5 Lambda Grey 6 Lambda Blue N Power Zero 230 VAC L Poiwer Phase 230 VAC Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se A m Outlets of the expansion card Remember to always cut the power to the boiler before starting any work on it All electrical work should be done by a certified electrician for your
50. ghten the two bolts Check that the square tube is in the middle of the hole in the inner tube AG 6 Hon When you reassemble the ignition device make sure to push it all the way to the front of the burner tube If there is a gap ignition and cleaning is impaired Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se The chimney Inspection We recommend you to let the local chimney sweep inspect give advise and instrucions about necessary actions on the chimney and connections Some points to consider before and after the commissioning of the installation Dimensions You can see suitable dimensions in the table below The chimney should be so long that the draught at standstill is between 5 10Pa A large or small chimney may have to be adjusted to give a tolerable draught and flue gas stream The included draft stabiliser should be used unless Effecta has recommended otherwise in specific cases The flue gas temperature must be controlled Directly after the boiler we recommend a flue gas temperature of 160 200 C With a high chimney or chimney with a big area there is a risk of condensation which can lead to corrosion and frost damage Measure the temperature 1m down from the top of the chimney the flue gas temperature should be at least 80 C measure when the burner almost has reached its stop temperature If you have too low flue gas temp
51. gsbacka 0300 22320 info effecta se Documentation of settings Before you as a installer commision the boiler system we ask you to fill out the different values set in the menus This is important for the future services and makes it easier in the communication between the customer and the installer and between the installer and Effecta Settings for the system Menu Parameters Value Temperature set Start temp burner Temperature set Stop temp burner Fan Burner fan speed Fan Burner fan lowspeed Fan Boiler fan operation speed Advance Fan start Advance Oper phase start Advance Fan Pulse 1 2 3 El heater Temperature el heater El heater Effect el heater Feeder Operation dose Feeder otart dose Installation Effect high and low if activated Installation Fan pre oper Installation Fan low pre oper ohunt group 1 Sensor heat curve room temp adjust Shunt group 2 Sensor room temp cylinder ohunt group 3 Sensor room temp cylinder Parameters operation with an accumulator tank Menu Temperature set Parameters Value Acc tank high G6 Temperature set Acc tank low G5 5 Type plate Tillverkare Manufactory Hersteller Fabricants Modell Model Effecta Komplett III Mod le Effecta Komplett III Light Effekt Heat output Heizleistung Puissance nominale kW Godk nd e
52. is avoided To confirm the desired effect is achieved it should be verified by the installer or property owner Tigex draft stabiliser has developed a design which enables mounting of the flue tube in all directions vertical angled as well as horizontal Tigex is mounted on a adaption plate which can be located where it is best suited on the flue tube Adjusting the balancing shaft To adjust this shaft loosen the two screws a bit and turn the shaft so that it is horisontally when the hatch is closed Then fasten the screws Adjusting the draft By moving the counterweight along the balance shaft the draft needed to open the hatch is adjusted About 1Pa per 2mm fig 2 The hatch is preset at about 10Pa A professional should measure the draft and make the adjustments Functions Tigex draft stabiliser opens the hatch just as much as is needed depending on the current draft The draft varies a lot depending on the chimney weather and also if the burner is running or not This means that the hatch can be open a lot a little or closed depending on the situation and the need for ventilation in the chimney The need for ventilation in the chimney varies greatly between different sites so the required pressure and ventilation needs must be determined on a case to case basis CLOSED LOCK OPEN i COUNTER WEIGHT CLAMP E BALANCE SHAFT Eur SCREWS FOR LOCKING n SF 10 Fa 15 m 20 25 P
53. let on the market The quality and energy can vary between them The diameter is 6 8mm the normal length is between 5 and 30mm High quality pellets have a density of 600 750 kg m3 The moisture content is 5 9 in weight Oil has an energy content of 9 9kWhr kg and wood logs about 4 0kWhr kg Wood pellets have a energy content of 4 7 5 0kWhr kg To maintain good combustion the pellets should be stored in a dry place and be protected from dirt Pellets are delivered in sacks with 10 15kg content or in bulk by truck The Effecta Komplett can handle most of the different types of wood pellets that are between 6 8mm but in UK only 6mm should be used The quality should meet DIN standards Good pellets with a small amount of dust and that are uniform helps achieve good combustion less maintenance of the product and also less environmentally harmful emissions The worse the quality of fuel is the more cleaning and maintenance of the product will be required The amount of pellets fed into the burner should be controlled every time the pellet brand or quality is changed If the deviation is more than 5kg hour compared to the a numbers in the Warranty and Installation paper the burner should be tuned Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 9 Boiler room It is time to install the Effecta Komplett IIl pellet boiler Please follow the examples we provide for a safe installation Afte
54. m ignition mode to operation mode Lowest approved value in operation mode If lower ALARM BURNER Time before ALARM BURNER when flame sensor lower than level oper Time before the fan goes to max speed Degrees temp shall fall before burner goes to quick start The time in which the temp shall fall CO degrees before burner activates quickstart oettings of required oxygen level in combustion Possible calibration of lambda Fan speed in Fan Pulse 1 Fan speed in Fan Pulse 2 Fan speed in Fan Pulse 3 Time before the fan starts Time before the burner goes into operation Number of registrated ignitions Number of hours the igniter has operated Number of hours the burner has operated Number of starts the compressor has done Registration of which Ign sequence ignition occurs Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Menu system Heating system Shunt group 1 Shunt group 2 Shunt group 3 El heater Shunt control Sensor Room temp Flow temp Radiator pump Max flow temp Min flow temp Max room temp Min room temp Heating off Outdoor temp Heat curve Slope Adjustment Energy saver DHW Priority Shunt group 1 amp 2 Sensor Flow temp Radiator pump Current control Energy saver DHW Priority Energy saver Lowering temp 5 C ore E AME VA 277 Tue AV Sion 477 DHW Priority Temp G1 min Max flow temp El heater
55. mode Off for this function Proximity sensor The proximity sensor is mounted from the factory When the light is on there are pellets near the top of the storage If the ATI a sensor needs to be adjusted it should be done when the storage Ve a full Find the setting for On Off on the screw Adjust it so that the light is lit Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta mm m Suction system and storage Storage If you build your own storage make sure that the walls can take the pressure of the pellets It is also important that the storage is completely tight so that it does not allow dust to escape An inspection hatch must also be installed so that you can serve and clean the storage when needed Suction nozzle In your system you need to install one or more suction nozzles The nozzle collect pellets from storage via the suction hose that is connected to the internal storage The number of nozzles needed depends one the size and shape of the storage On pg 22 you can see how to place them Switch For every nozzle you need a switch The switch is placed on the storage If several nozzles are installed you complement the switch with a connector and a cover plate When the pellets have ran out at a nozzle you just switch connector 1 Suction to boiler Return from boiler 3 Mounting plate inclined wall Mounting plate floor
56. n order to increase the temperature turn 1 towards You may also need to tune the flow valve 6 to reduce the flow through the coil There is a safety valve 9 that releases the water out of overflow tube 10 if the pressure the hot water 4 circuit is too high Note that overflow pipe should 6 2 always drain to a floor drain Temperature control Flow control valve Hot water Mixing valve Cold water Vent pipe Hot water out Safety valve 5 0 Cold water in Overflow pipe Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Shunt control In the Shunt control menu you choose how to control the heating of the house Start by deciding which sensors to use room outdoor sensor or both When you choose both the room sensor only works as a logger of the temperature which is shown in a curve The room sensor also lowers the flow temp by 5 C if max room temp is reached If both sensor are connected you have to choose both in the menu for the system to work Room sensor If the room sensor is used it is recommended to be installed in a open space near the center of the house The sensor shouldn t be influenced by draught doors sunlight directly to it or other heat sources since it then will affect the heating output to the entire house Loosen the control wheel by pulling outwards Then loosen the screw to
57. ngsbacka 0300 22320 info effecta se m Change of the igniter Cut the power to the boiler Loosen the main cable to the burner the cable to the flame sensor and the compressed air hose to the burner 1 Remove the four wing nuts 2 which are holding the rear housing against the end plate of the outer combustion tube Angle the rear housing and pull it upwards backwards so that the fall shaft loosens from the inner tube Then detach the pipe to compressed air by unscrewing the quick connector on the outside of the rear housing Then disconnect the ignition element wires on the terminal block located under the metal lid of the electrical console 3 Remove the ignition device from the rear housing by taking out the two screws on the bottom of the burner 4 Ignition element clamp is removed 5 and the element is pulled out of the square tube olide the new element in the square tube Push so it lies on the outer edge of the square tube 6 Install the clamp and tighten the screws with moderate force so that the element is not going to fly back and forth Insert the ignition device in the rear housing The cables should be pulled out through the fan s cable access Connect the cables on the console Secure the two cables to each other with a cable tie Reassemble in reverse order wait to fasten ignition device in the burner until the burner is mounted together with the outer tube Push the ignition device to the burner tube and ti
58. nl Approved by Zugelassen nach Approuv Effecta Energy Solutions AB Milj klass Emission class Emissionsklasse Classe d mission Max drifttryck Max pressure Max Betriebsdruck Pression maximum bar Max drifttemp Max temp C Max Betriebstemp Temp d op ration max Elinstallation Electrical suppl Elektroanschluss Branchement lectrique 230 380 50Hz El patron Electrical heater kW El Patrone El cartouche Vattenvolym Water volume Wasserinhalt Contenance d eau litre Bransleklass Fuel class Brennstoffklasse Classe d carburant EN Plus DIN Plus Tillverknings nr Manufacturing number Herstell Nr Num ro de fabrication Tillverknings ar Manufacturing year 2014 2015 2016 2017 2018 Tillverknings m nad Manufacturing month ul 48 MJ NM NJ of EIU 118 12m Effecta AB Sweden Kungsbacka www effecta se Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Temperature set Stop G5 Temperature set Max G6 Temperature set Start G6 Temperature set Max G1 Komplett 111 1 Radiator fram Flow Vorlauf Depart radiateurs 2 Radiator retur Return Rucklauf Retour radiateurs standard mounting of the pex tube 3 Kallvatten in Cold water in Kaltwasser Eau Froide ECS 4 Varmvatten ut Hot Wat
59. ntenance and ash cleaning of the con vection section The magnet is controlled from the Cleaning menu there you can set the times it allowed to clean The magnet is relatively quiet and if it doesn t disturb it should be allowed to clean around the clock Magnet The magnet is mounted on the right side of the boi ler The magnet lifts the turbulators in the tubes Lifting shaft Rotating the lift shaft lifts the turbulators and clean the tubes Turhulators The turbulators in the tube help by reducing the flue gas temperature and also cleaning the tubes when pulled up and down Suspension On every suspension there are two turbulators that are removed when cleaning the tubes with a brush Flipper Flips when the magnet motor activates 1 Magnet 2 Lifting shaft 3 Flipper 4 Susoension 5 Turbulator Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta mm Disassembly for move The boiler is fully mounted when delivered If the boilers width exceed the door you can disassemble it to a smaller size Remove the cover of the suc Then remove the 4 plastic Loosen the 4 screws and tion system If the boiler has covers which conceals the remove the cover plates an internal storage remove screws for the cover plates the screws which holds the They hold the coverplates to top part the internal storage Aj
60. oiler there are eight 1 conduits that end in the front of the boiler These are used to connect the sensors and electrical cables Don t put the low and high voltage in the same hose it can effect the showing of temperature To remove the front casing grab the two handles and pull it straight out hard Then connect the input voltage to the card s ports Power guard 208 If the electricity comsumption is high in the pro while the electrical heater is a operating there is a risk that the pro pertys main fuses will blow The Effecta Komplett Ill is equipped with a power guard which prevents electrical over load by redistributing the power supply between the phases Connection of current sensors To measure the power you must install one current sensor to each incoming phase in the house This must be done directly in the electrical control Con nect the sensors to a cable with the area of 0 5mm2 to the circuit board In the electrical heater menu you set the max power that s allowed on the fuses in your house Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 23 m Outlets of the motherboard Remember to always cut the power to the boiler before starting any work on it All electrical work should be done by a certified electrician for your 9 saf
61. open the box 1 Connected to number 3 on the motherboard 2 Connected to number 4 on the motherboard 3 Connected to number 5 on the motherboard Outdoor sensor If an outdoor sensor is used this should be mounted on the facade of the house It is important the sensor is mounted on the north side of the house Make sure that the sensor isn t disturbed from solar gain It is recommended that the sensor is mounted about 2 metres from ground level and if possible protected from water and such Loosen the screw and split the casing lt is then possible to mount the box to the wall 1 Connected to 1 on the motherboard 2 Connected to 2 on the motherboard Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Tuning the boiler The appropriate heating curve is essential in order to have the right indoor temperature The heating curve needs to be adjusted to the specific energy demands of the house it is installed in All houses have different demands which could mean that one house would need a 25 flow at a outdoor temperature of 0 C while another house needs 45 Adjustment to the heating curve is done in the Shunt control menu In this menu it is possible to alter both the slope and the adjustment to the curve To find and adjust the correct heating curve it is important that the following points are fulfilled The out
62. over the frame loosen the two bolts 2 on the outside of the door Loosen the bolts abouts two turns and adjust the door 3 Lateral adjustment To centre the sealing sideways loosen the two bolts 2 and adjust with the the two bolts C3 Make sure to tighten all bolts when adjustment is completed Adjustment of the door locking If the seal is not tight on the handle side loosen the two bolts 1 which holds the lock in place Loosen about two turns and push the lock inwards to tighten and reverse to loosen If the door handle is not in a horizontal position when the door is closed you can adjust the bolt 2 up or down to change the position Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se 47 Trouble shooting There are actions that the end user can take to fix a fault However a professional should always be advised before doing any adjustments Fault Cause Action No start dose while tuning No underpressure Seal the hole to the fallshaft Burner does not ignite Incorrect start dose High draft in the chimney gniter faulty gniter console poorly attached Burner tube filled with ash Adust start dose Adjust draft stabiliser Change igniter Adjust console Clean the burner Burner tube filled with ash Overheat protection fallshaft tripped Reset Feeder malfunction Check feeder The display is black Ove
63. r installation be sure to instruct the customer on how the heating system and the boiler works in order to avoid unnecessary complications in the future Set up The boiler is positioned so that the surface temperature of flammable building material does not exceed 80 C The boiler should be positioned at least 10 cm 1 from the wall If the distance between the flue tube and flammable wall is less than 30 cm an ignition protective covering must be used 4 In order to clean the boiler a minimum clear space of 1 metre 2 is required in front of the boiler A passage with a minimum width of 0 5m 3 ee i is required along one of the long sides of the boiler Check the regulations of your country in order to place the pellet hopper an approved distance from the boiler Boiler room The boiler must be installed in a boiler room or boiler house The ceilings and walls must be fitted with ignition protective covering and the floor must be made of non combustible material Minimum ceiling height in the boiler room is 2 metres The boiler room or boiler house must be equipped with a fresh air intake with the minimum dimensions 150 x 150 mm 5 or with a sufficiently large free sectional area to avoid low pressure in the boiler room It must be impossible to close the air intake Chimney The chimney should have enough area to manage the effect from the boiler At standstill the draft should be between 5 10pa It is import
64. rheat protection on boiler tripped Reset protection Overheat protection fallshaft tripped High back pressure in the chimney Check draft Clean the burner Ashes are totally black Poor combustion Contact your installer Poor hot water capacity Low temperature in the boiler Too high flow in the pipes Too big diff between start and stop Set the burners Stop temp higher Adjust the flow on the mixing valve Reduce diff Low high indoor temperature Soot in the boiler room Incorrect temp on sensor Sensor untrimmed Improperly placed room sensor Improper tuned curve to outdoor sensor Leaking seals Adjust temp curve to the sensor Calibrate the temp Move sensor to a suitable position Adjuste curve Contact your installer Alarm flue gas flue gases over 320 C Sooty boiler Poor combustion Broken sensor Clean the boiler Contact your installer Change Contact your installer No heat on radiators Shunt motor closed Shunt motor broken Radiator pump not activated Radiator pump broken Air in the radiator circuit Contact your installer Contact your installer Activate in Shunt control Contact your installer Vent the circuit White smoke from the chimney Low flue gas temperature Too big chimney Rain water in the chimney Cut turbulators increase effect Contact your installer Mount a rain hoo
65. ring Flue connection Handle Front cover Shunt valve BR OIN Handle storage lid Display Gas damper Conduit for sensor Connector feed motor auger RR WIN gt Internal storage Mixing valve for hot water 12 Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 Not on Light 22320 info effecta se m Placement of components vacuum system Front Back Top Adjustable feet Drain cock Flue gas measuring point Ash door Return hot water circuit Boiler fan Handle ash door Flow hot water circuit Cleaning access Front cover Hoses electrical wiring Flue connection Handle Front cover Shunt valve OINI gt Draft stabiliser Display Conduit for sensor Insulated cover plate Connector feed motor auger Not on Light Lower cover plate Mixing valve for hot water Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Placement of components vacuum system oide Front Top Meltable plastic tube Fallshaft Vacuum fan oafety ball valve oafety lock Connection hose suction nozzle Internal feeder 0 Internal feed motor 0 Capacitive sensor
66. s are on pg 33 Door switch The door switch stops the auger feeder and no more pellets are fed into the burner when the door to the combustion chamber is open Automatic fuses Automatic fuses are installed in the electrical system which are triggered if there are any eletrical faults in the boiler If triggered an authorized electrician should be contacted to determine the cause Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Components The shunt valve The shunt valve is connected to the boiler or accumulator tank The shunt valve controls the heat supply from the boiler to the heating circuits of the house Heat regulation The boiler is equiped with its own heat regulator In the Shunt control menu you can choose how to control the heat in the house More on how to regulate the heat is found on pg 36 The thermostatic mixer valve The mixing valve is used to ensure that the temperature of the hot water in your shower and elsewhere in the house is comfortable Set the system to the tem perature you want by turning the thermostat between If you have a Komplett Light the mixer valve is mounted on the accumulator tank Feeder The feeder is either internal or external on the boiler The feeder controls the amount of pellets fed to the burner The hurner The burner is mounted on either the right or left side The fuel from th
67. software It s important not to interrupt the updating procedure this will damage the controller Wait until the picture of flags comes up on the display Disconnect the USB memory Your boiler is now updated Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Tuning the boiler It is important that the start dose is absolutely accurate and 40 cl if it is incorrect the boiler will not run correctly The boiler is rough set when delivered Before the first start an easier tuning of the fans must be done Always use a flue gas alalyzer when tuning the combustion Fans In the Fan menu you set the fan speed After you have measured the start and support dose you fine tune the combustion with the burner fan speed The boiler fan must always have a speed that builds underpressure if not no pellets will be fed In operation the boiler fan is set 50 80 the higher effect of the boiler requires higher speed The burner fan fine tunes the combustion Start dose Before the start dose is adjusted you need to make sure that the feeder is filled You fill the the feeder by activating Fill feeder in the menu Then choose Run start dose in the feeders menu Measure 40cl Repeat several times Boiler effect In the Installation menu you set the boilers effect If you have activated low speed also set it Check the oper dose by activating Run oper dose The feeder then compresses
68. sor external Brown N Zero 77 Proximity sensor external Black 30 Extra 2A 230 VAC 78 Proximity sensor external Blue 79 Proximity sensor external White Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se e 5 O 5 il lt 9 1 Lu 2 09 XW a gt aa ha E i EE S H313IA 3H3d AV fio Y gt gt X E YSLSWOHOVL ama O S gt 1HVAS H313AOHOV L D oO yy by a e c o c S x Lu gt HOlVIQvH 5 O A Q HOLOW LNNHS gt anal umiog N3dO e 9 Lu us z 2o Svo 3n
69. ta Komplett Ill 20 25 35 kW Effecta Komplett Ill Light 20 25 35 kW som omfattas av denna f rs kran ar i verensst mmelse med f ljande direktiv to which this declaration relates is in confirmity with requirements of the following directives auf das sich diese Erkl rung bezieht konform ist mit den Anforderung der Richtlinien auxquels la pr sente d claration s applique sont conformes aux xigences des directives suivantes EC directive on Electromagnetic Compatibility EMC 2004 108 EC Machinery directive Low Voltage Directive LVD 2006 95 EC Pressure Equipment Directive PED 97 23 EC This pressurized equipments are not covered by Article 3 in EU Directive 97 23 EC However as prescribed in item 3 of this article the equipments are designed and manufactured in accordance with the sound engineering practice of a member state in order to ensure safe use Overensstammelsen kontrollerad i enlighet med f ljand EN stadarder The conformity was checked in accordance with the following EN standards Die Konformit t wurde berpr ft anhand der EN Normen Cette conformit t v rif e selon les normes suivantes EN 287 1 2004 EN 303 5 EN 10 204 2005 EN 50 366 2003 A1 2006 EN 55 014 1 2006 EN 55 014 2 1997 A1 2001 EN 60 335 1 2002 A1 2004 A2 2006 A11 2004 A12 2006 A13 2008 EN 60 335 2 21 2003 A1 2005 A2 2008 EN 60 335 2 102 2006 EN 61 000 3 2 2006
70. that you need to specify the main fuse of the house if you only have 16A it is not sure you can run the el heater in full effect 9kW then you need to install power monitors Set which temperature you want the el heater to start if there is a disruption or if the pellets has ran out Set the temperature 5 C below the burners start temperature so that it does not activate unnecessarily If you have a Light the boiler has no electrical heater Cleaning In the Service menu you set how often the boiler should be cleaned For minimal maintenance it should be actived as much as possible You can also block the cleaning during some times of the day night Clock In the Other menu you can set the clock The clock controls functions such as night blocking Shunt control In the shunt control you can choose between room sensor outdoor sensor both or constant You can activate 3 different shunt groups When you choose both the room sensor only works as a logger and a regulator of the indoor temperature Choose the appropriate curve for your house The curve might have to be ad justed several times before you find the ideal indoor temperature When you choose Room sensor the desired temperature is set on the included thermostat There is no temperature scale on the sensor so you change the temperature on the boiler Place the sensor in an open area of the house where there is no interference from other heat sources In order to get the right
71. the pellet Test run of start dose for measuring Only available in burner mode off Test run of supp dose for measuring Only available in burner mode off Test run of operation dose for measuring Only available in burner mode off Shows the boiler temp start stop sensor with overheating function Temperature when the burner goes to standby mode Temperature when the burner starts up from standby mode When loading acc tank sensor G6 is installed at the tank top of the primary tank The sensor starts the burner at set temp Only shown if mounted Temperature when burner stops Maximum allowed temperature G6 tank overheated Temperature when burner starts Temperature when loading pump starts Time loading pump runs Displays the number of burner starts been done Displays the number of hours ignitor has been lit Displays the number of hours the burners been running Displays the number of times the AERO unit has cleaned the burner Resets the information above Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Menu system Service Clean at phase out On Interval Number clean Clean pause Cleaning conv Flue gas Max time burner External control Installation Advanced Fill feeeder Effect high speed Effect low speed Testblow Phase out Fan pre oper Fan low pre oper Clean phase out Flame sens Quickstart Lambda Time between filling Night block Fill
72. this information can affect the performance of the product Dangerous electricity This symbol means that extra caution should be taken otherwise serious personal injury A might occur When maintaining the product where this symbol is present the power must be disconnected All electrical wiring must be done by a Professional and comply with current building regulations Hot surfaces This symbol is shown when there is a risk of burns to people Always wait for the boiler to cool down before you do any service The product manual is a document that gets updated You always find the latest version on our webpage www effecta se Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se Your safety Remember to always disconnect the power before working with the boiler N Wait until the boiler has cooled down before starting work et Before using the product the owner and or other user must read and understand the content in this manual The directions must be followed This is to make sure that the product is functioning correctly so accidents and injuries are avoided Incorrect use or burner adjustment can result in damage to property and personal injury or poorer performance of the product The boiler room where the product is installed the chimney and other components must be approved according to current legislation The commisioning of the product must be made by a profession
73. u m m mi mm 20 nmm 30 n 40 mm 20 10 n Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Overheated fallshaft There is a overheat protection located on the burners fallshaft This prevents back heat If the protection has tripped the power to the feeder is cut The cause of overheating is usually due to back pressure in the boiler being too large which in turn is usually due to The burner tube is full of ash The boiler is full of ash The chimney is too narrow The burner is set on a too high effect Reset the protection by removing the cover plates of the boiler Then press the reset button 1 you should hear a click when it is reset If the protection is tripped again we recommend you to contact your installer to look over the function and settings of the boiler E Change of burner fan Cut the power to the boiler Remove the cover plates needed Unscrew the lid of the electrical box 1 and remove the cable ties loosen the cables for the igniter 2 and the fan 3 Unscrew the four hexagon socket screws size 2 5 and remove the fan 4 The cable for the igniter is pulled through the fan Mount the new fan in reverse order After a change of burner fan measure the flue gases as you might have to tune the burner slightly due to fans having some variations in speed Effecta AB Vastra Ragdalsvagen 21 434 99 Ku