1. el plex TECHNOLOGIES LLC USER MANUAL Stand Alone Power Supply PSQ 2909 PSO 3909 PSO 4909 PSQ 2920 PSQ 3920 PSQ 4920 This page intentionally left blank Warning for Your Protection Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with a dry cloth Do not block any of the ventilation openings Install in accordance with the manufacturer s instructions ou no un PWN PR Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is u
2. Made in the USA Input 100 240 VAC y 50 60 Hz 120 50mA Output SVDC 1A Theries berplex com fi 301 604 0100 79 2006 6 Figure 2 PSQ 4909 Dimensions Input 1248 VDO Output SVDC 1A Poincar goce Iberplex com 301 604 fi 0100 SS Jl OL Figure 3 PSO 4920 Dimensions Pber pilex TECHNOLOGIES LLC 18040 412 Guilford Rd Annapolis Junction MD 20701 UMPX909 fiberplex com clients fiberplex com 301 604 0100 150724
3. TDU 4000 Size 3 PSQ 3909 PSQ 3920 FOI 4xxx thru FOI 9xxx Size4 PSQ 4909 PSQ 4920 Includes both FOI and FIS variants Other Considerations TEMPEST Support TEMPEST is a US Government specification and NATO certification intended to protect valuable and mission critical information from being intercepted through leaking emanations including unintentional radio or electrical signals sounds and vibrations The protection efforts are also known as emission security EMSEC which is a subset of communications security COMSEC Several FiberPlex Technologies FOI units have a variant designated with a T ST suffix which has been rigorously designed and tested to comply with TEMPEST requirements These units can easily be visually identified by their silver finish An RFI suppressed version of the PSQ 4909 AC power supplies have been tested with the TEMPEST FOI units and should be used with those units as part of a complete certified TEMPEST solution This version can be ordered using an R suffix after the model number PSQ 4909 R When using TEMPEST rated FOI much care must be taken in both the mating equipment and especially the copper cabling used in such connection In addition the power supplies and or chassis being uses must have an R suffix For standalone applications use a PSQ 4909 R or the older PSQ 4910 R power supply or for a chassis mounted solution use either an RMC 3101 R or RMC 2101 R chassis All the ite
4. installation must be monitored e g for fan failure or illumination with spot lamps the exhaust air temperature must be measured directly above the modules at several places within the enclosure Grounding and Power Supply Grounding of units with mains supply class I eguipment is performed via the protective earth PE conductor integrated in a NEMA 5 15P connector Units with battery operation lt 60 V class Ill equipment must be earthed using the 3 pin Phoenix connector Grounding the unit is one of the measures for protection against electrical shock hazard dangerous body currents Hazardous voltage may not only be caused by defective power supply insulation but may also be introduced by the connected audio or control cables This equipment may require the use of a different line cord attachment plug or both depending on the available power source at installation If the attachment plug needs to be changed refer servicing to qualified personnel Warranty Service and Terms and Conditions of Sale For information about Warranty or Service information please see our published Terms and Conditions of Sale This document is available on fiberplex com or can be obtained by requesting it from clients fiberplex com or calling 301 604 0100 Disposal Disposal of Packing Materials The packing materials have been selected with environmental and disposal issues in mind All packing material can be recycled Recycling packin
5. g saves raw materials and reduces the volume of waste If you need to dispose of the transport packing materials recycling is encouraged Disposal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer or via the public waste disposal system ensuring any material that can be recycled has been Please take care that your used equipment cannot be abused After having disconnected your used equipment from the mains supply make sure that the mains connector and the mains cable are made useless Disclaimer The information in this document has been carefully checked and is believed to be accurate at the time of publication However no liability is assumed by FiberPlex for inaccuracies errors or omissions nor for loss or damage resulting either directly or indirectly from use of the information contained herein Introduction The PSQ 2909 PSQ 3909 and PSQ 4909 are compact AC power supplies that attach to and provide operating voltage for FiberPlex s FOI series isolators The PSQ 2920 PSQ 3920 and PSQ 4920 are compact low voltage power supplies that attach to and provide operating voltage for FiberPlex s FOI series isolators They can power the FiberPlex FOI units with a 12 48 VDC or 10 32 VAC external supply These Low Voltage power supplies are not polarity sensitive V and V may be reversed f
6. ity of the operating environment must be within the specified limits during operation of the unit Values specified are applicable to the air inlets of the unit Condensation may not be present during operation If the unit is installed in a location subject to large variations of ambient temperature e g in an OB van appropriate precautions must be taken Unobstructed airflow is essential for proper operation Ventilation openings of the unit are a functional part of the design and must not be obstructed in any way during operation e g by objects placed upon them placement of the unit on a soft surface or improper installation of the unit within a rack or piece of furniture The unit must not be unduly exposed to external heat sources direct sunlight spot lights Ambient Temperature Units and systems by FiberPlex are generally designed for an ambient temperature range i e temperature of the incoming air of 5 40 C When rack mounting the units the following facts must be considered The permissible ambient temperature range for operation of the semiconductor components is O C to 70 C commercial temperature range for operation The airflow through the installation must allow exhaust air to remain cooler than 70 C at all times Average temperature increase of the cooling air shall be about 20 C allowing for an additional maximum 10 C increase at the hottest components If the cooling function of the
7. ms in the system must be TEMPEST compliant for the system to properly protect the information Specifications ELECTRICAL SPECIFICATIONS Min Typ Max Unit Power Requirement Input Voltage 100 240 VAC PSQ x909 AC Supplies Input Frequency 50 60 Hz Output Voltage 9 VDC Supply Current 1000 mA Output Power 9 Ww Power Requirement Input DC Voltage 12 48 VDC PSQ x920 Low Volt 97x320 Low Voltage Input AC Voltage 50 60 Hz 10 32 VAC Supplies Output Voltage 9 VDC Supply Current 1000 mA Output Power 9 3 Ww Environmental Storage Temperature 40 85 C Operating Temperature 0 50 C PSQ x909 NEMA 5 15P Permanently Affixed Power Connector PSQ x920 Phoenix Contact 1827716 PHYSICAL SPECIFICATIONS FOI Size Case Dimensions PSQ 2909 2 225in 57mm 2 56in 65mm 1 31in 33mm 0 8 lb 0 4 kg PSQ 3909 3 2 38in 60 mm 3 19in 81mm 1 45in 37mm 0 8 Ib 0 4 kg PSQ 4909 4 225in 57mm 2 56in 65 mm 1 45in 37mm 0 8 lb 0 4 kg PSQ 2920 2 2 25in 57mm 2 56in 65 mm 1 31in 33mm 0 8 lb 0 4 kg PSQ 3920 3 2 38in 60 mm 3 19in 81mm 1 45in 37mm 0 8 lb 0 4 kg PSQ 4920 4 2 25in 57mm 2 56in 65 mm 1 45in 37mm 0 8 lb 0 4 kg 2 56 65 1 2 25 38 57 1 9 5 Oe oo 3 O S r
8. or DC inputs They are equipped with a resettable fuse to protect both the supply and the FOI Getting Started Initial Inspection Immediately upon receipt inspect the shipping container for damage The container should be retained until the shipment has been checked for completeness and the equipment has been checked mechanically and electrically If the shipment is incomplete if there is mechanical damage or if the unit fails to operate notify FiberPlex and make the shipping materials available for the carrier s inspection Installation Instructions 1 Locate the FOI to the PSQ as shown the power plug slides straight into the mating receptacle 2 Start the captive screws into the FOI face Do not tighten completely until both are threaded 3 Tighten snugly the captive screws evenly drawing the faces together The mounting face of the FOI should be in uniform contact with the face of the PSQ D Figure 1 PSQ Installation Note The PSQ 4909 is shown The PSQ 2920 PSQ 3920 and PSQ 4920 Low Voltage power supplies do not have the AC adapter cable Compatibility The PSQ series power supplies are compatible with all FOI and FIS style Fiber Optic Isolators The table below shows compatibility See the specifications section in the user manual of your FOI to determine the Size of the FOI FiberPlex FOI Series Size AC Power Supply Low Voltage Power Supply FOI 2xxx Size 2 PSQ 2909 PSQ 2920 FOI 3xxx
9. sed use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to gualified service personnel Servicing is reguired when the apparatus has been damaged in any way such as power supply cord or plug is damaged liguid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped The apparatus shall not be exposed to dripping or splashing No objects filled with liguids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture General Installation Instructions Please consider these general instructions in addition to any product specific instructions in the Installation chapter of this manual Unpacking Check the eguipment for any transport damage If the unit is mechanically damaged if liguids have been spilled or if objects have fallen into the unit it must not be connected to the AC power outlet or it must be immediately disconnected by unplugging the power cable Repair must only be performed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperature and the relative humid