Home

Rental power box

image

Contents

1. 7 4 Physical installation Qa 9 4 1 Components of the rental power box 11 ysam EE Mela derit ee ed 9 42 Setup of the rental power 007 hh s a nh e n n n nn nnn 10 4 3 Connections between rental power box and 0 III mese ehm n enn 10 A Addendum 7 s ud L Saa 13 A 1 Identification system of a power distribution network according IEC 964 13 A2 Diagrams coro eter iren vs C ise ats eisai eid a aan x e Ne EDT ERO can s ERE C WERE RC EET Ie Hid 13 spo Sen ra E tin M A AES AAA E OA TO A SE 17 R5976615 RENTAL POWER BOX 14052004 1 Table of contents 2 5976615 RENTAL POWER BOX 14052004 7 Safety 1 SAFETY 1 1 Important Safety Instructions 1 2 Instructions Read this instructions Keep these instructions Heed all warnings Follow all instructions Do not use the power box in wet conditions Make sure that the power box is properly grounded For protection against electrocution a disconnect device must be provided in the beginning of the main power line to the power box Make sure the MAINS S
2. 14052004 Index INDEX A Power box 5 Addendum 13 P Power box 5 10 Cables 7 Connections 10 Components 9 General functionality 5 Connections 10 Order info 5 Power box 10 Set up 10 D R Diagrams 13 Rental Power Box 5 Technical summary 5 S General functionality 5 Power box 5 Safety 3 Important Safety Instructions 3 Important Warnings 3 Setup 10 Power box 10 IEC 364 13 Installation 9 Introduction 5 T Technical summary 5 0 Order info 5 7 R5976615 RENTAL POWER BOX 14052004
3. CEE form each protected with a 16 A switch fuse 20 kA short circuit rating AC MAINS 230 400 V switch Padlockable phase selector switch Changeover with centre off Select voltage between any two phases or between any phase and neutral Measure unit Power meter PM500 Measure functions 1 U F PGA PF THD Imax Pmax H E Protected with a 6 A switch fuse Input voltage 230 V 3 phase 400 V 3 plus neutral Maximum input current Suitable power nets TT and TN Can be used with a local power s but the centre point of the power generator must be grounded Output voltage 230 V on the multi pole connectors and on the auxiliary connectors Maximum output current 6 circuits of 16 A per multi pole connector 16 A on the auxiliary connectors Ruggedness IP30 Weight flightcase included 93 kg R5976615 RENTAL POWER BOX 14052004 5 2 Introduction Dimensions flightcase 685 x 656 x 670 W x D x H Regulation compliance CE IEC 60947 2 Output voltage 230V on each output circuit multi pole and auxiliary Maximum output current 16A maximum for each output circuit multi pole and auxiliary 6 5976615 RENTAL POWER BOX 14052004 3 Cables used with the rental power box 3 CABLES USED WITH THE RENTAL POWER BOX Cables This chapter only enumerates and describes power cables used between the rental power box and the Barco LED wall Power cables used between tiles are listed in the installation manual of the
4. concerned tile Some power cables can be used as well indoor as outdoor Other may only be used indoor The use of indoor or outdoor cables depend on the type of LED display 3 1 Order info power cables Order info R9851260 Multi power cable of 10 meter For indoor and outdoor use Used to distribute power between rental power box and spider connector R9851261 Multi power cable of 20 meter For indoor and outdoor use Used to distribute power between rental power box and spider connector R9851262 Multi power cable of 30 meter For indoor and outdoor use Used to distribute power between rental power box and spider connector R9851263 Multi power cable of 50 meter For indoor and outdoor use Used to distribute power between rental power box and spider connector R9851264 Multi power cable with custom length For indoor and outdoor use Used to distribute power between rental power box and spider connector R9851660 Waterproof spider connector for outdoor use with 6 power outputs C19 with different length Spider support bracket included Used to subdivide power from a multi power cable to a group of tiles R9851661 Waterproof spider connector for outdoor use with 6 power outputs C19 with same length Spider support bracket included Used to subdivide power from a multi power cable to a group of tiles R9851662 Waterproof spider connector for outdoor use with 6 power outputs C19 with custom length Spider support bra
5. BARCO EVENTS RENTAL POWER BOX OWNERS MANUAL 14052004 R5976615 01 Barco nv Events Noordlaan 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail events barco com Visit us at the web www barco com Printed in Belgium Copyright All rights reserved No part of this document may be copied reproduced or translated It shall not otherwise be recorded transmitted or stored in a retrieval system without the prior written consent of Barco Guarantee and Compensation Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee On receipt the purchaser must immediately inspect all delivered goods for damage incurred during transport as well as for material and manufacturing faults Barco must be informed immediately in writing of any complaints The period of guarantee begins on the date of transfer of risks in the case of special systems and software on the date of commissioning at latest 30 days after the transfer of risks In the event of justified notice of compliant Barco can repair the fault or provide a replacement at its own discretion within an appropriate period If this measure proves to be impossible or unsuccessful the purchaser can demand a reduction in the purchase price or cancellation of the contract All other claims in particular those relating to compensation for direct or indirect damage and also damage attributed to the operation of
6. UPPLY VOLTAGE selector is standing in the corresponding position to the supplied voltage before engaging the power box Measure the outgoing voltage on the power output connectors before connecting any devices with the power box Protect the power cords from being walked on or pinched particularly at plugs convenience receptacles and the point where they enter or exit the power box Refer all servicing to qualified service technicians personnel only Do not use this power box with an IT power distribution network A neutral conductor must be provided The centre point of the power generator must be grounded when using a local power generator Important Warnings Important warnings Risk of electrical shock CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Image 1 1 Risk of electric shock Do not open To reduce the risk of electric shock do not remove cover or back No user serviceable parts inside Refer servicing to qualified service personnel The lightning flash with an arrowhead within a triangle is intended to tell the user that parts inside this product may cause a risk of electrical shock to persons The exclamation point within a triangle is intended to tell the user that important operating and or servicing instructions are included in the technical docume
7. cket included Used to subdivide power from a multi power cable to a group of tiles R9851670 Spider connector for indoor use with 6 power outputs C19 with different length Spider support bracket included Used to subdivide power from a multi power cable to a group of tiles R9851671 Spider connector for indoor use with 6 power outputs C19 with same length Spider support bracket included Used to subdivide power from a multi power cable to a group of tiles R9851672 Spider connector for indoor use with 6 power outputs C19 with custom length Spider support bracket included Used to subdivide power from a multi power cable to a group of tiles R5976615 RENTAL POWER BOX 14052004 7 3 Cables used with the rental power box Image 3 1 Beeler multi pole connector plug Image 3 3 Multi power cable Waterproof spider connector output cables with different length Image 3 4 Image 3 5 Image 3 6 Waterproof spider connector output cables with same Spider connector for indoor use output cables with same Spider support bracket length length 8 lt _ 976615 RENTAL POWER BOX 14052004 4 Physical installation 4 PHYSICAL INSTALLATION 4 1 Components of the rental power box Rear side On the rear side of the rental power box are the connectors for power input and output as well the padlockable phase selector switch The number and the color of the output connectors correspond with the number and color of the
8. ected in parallel with the same power source cable Image 4 3 Power box Multi power cable Spider connector Power source cable spider output cable VOOD is limited Never connect more tiles than allowed See installation manual of the involved tiles to know the To protect against risk of fire by overloading of power cables the amount of tiles per power source cable maximum amount of tiles connected in parallel with the same power source cable R5976615 RENTAL POWER BOX 14052004 4 Physical installation Necessary parts Multi power cables Spider connectors Spider support brackets Power source cables How to realize the connections between the rental power box and the LED wall 1 a Oo Install a spider support bracket at the rear side of the LED wall Choose a place where all output cables of the spider connector will easily connect to the start point of a power branch Fasten the multi pole plug of a spider connector inside the spider support bracket Warning Always use waterproof spider connectors in case of an outdoor LED wall application Connect a single power source cable of the spider connector with the start point of a power branch of tiles in the LED wall Repeat step 3 until all six power source cables of the spider connector are connected with the LED wall Connect a multi power cable with the spider connector Ensure to fasten the locking cap of the spide
9. ge to the power box and the equip ment connected to it Tip Measure the voltage on the mains power cord before connecting to the rental power box 5 Place a padlock on the phase selector and connect the mains power cord to the rental power box 6 Switch on the main circuit breaker and the switch fuse named LOGIC This action will start up the power meter 7 Read out the phase to phase supplied voltages on the power meter See User manual of the power meter for instructions about reading out the phase to phase supplied voltages 8 Does the values of the phase to phase supplied voltages on the power meter correspond with the position of the padlocked phase selector If yes connect the equipment to the power box If no repeat this procedure starting from step 3 9 Now it is safe to switch on all other switch fuses of the rental power box 43 Connections between rental power box and LED wall General The rental power box is provided with multi pole power output connectors One multi pole connector contains six 6 power circuits each protected with a 16 ampere rated circuit breaker A multi power cable is used to transport the power from the multi pole connector to a spider connector This spider connector subdivide the power circuits into individual power source cables Each power source cable of the spider connector leads to a group of tiles See installation manual of the involved tiles to know the maximum amount of tiles conn
10. national Electro technical Commission R5976615 RENTAL POWER BOX 14052004 A Addendum 2 91 92 9 Inv N J N9V dC N09 nv 771 379 6 NOOM N093 Ah 2 91 92 N09 J N9L dZ N093 Jhv 7 Multi connector Image A 2 2 91 92 9 Inv Multi connector 19 pin S J V9L dz N09 nv 2 91 92 9 3 V9l dZ N093 2 791 92 NO93 2 91 92 N093 hv Image A 3 R5976615 RENTAL POWER BOX 14052004 14 A Addendum m Aut K60N 2P 16A C SS Romi Aut KOON 2P 16A C Gt Aut K60N 2P 16A C 95 Aut K60N 2P 16A C a Aut K60N 2P 16A C Aut K60N 2P 16A C a Image A 4 x lt lt a N S lt a 5 lt 5 CEE form 16A 2P A 16A 2P A AUX 1 AUX 2 Y Aut K60N 2P 16A C CEE form 16A 2P A AUX 3 Bm K60N 2P 16A C CEE form 6A 2P A LOGIC i Aut K60N 2P 6A C Power Meter Image A 5 R5976615 RENTAL POWER BOX 14052004 15 A Addendum 16 5976615 RENTAL POWER BOX
11. ntation for this equipment Wrong selection of the MAINS SUPPLY VOLTAGE can cause damage to the power box and the equipment connected to it R5976615 RENTAL POWER BOX 14052004 383 7 Safety 4 _ 5976615 RENTAL POWER 14052004 2 Introduction 2 INTRODUCTION 2 1 General functionality Overview The rental power box provides power 230VAC to run the full range of Barco LED Display systems i e DLite ILite and SLite It is dual voltage 230V 400V 3 phase and is eguipped with a digital power meter for easy voltage and current measurement The rental power box has three multi pole power output connectors which provide in total 18 protected power output circuits Furthermore the rental power box includes three multi purpose power outlets for energizing peripherals around the Barco LED wall 2 2 Order info rental power box Order info R9850990 Rental power box 2 3 Technical summary Summary Mains Input connector CEE form 63 A 3 phase plus neutral and protective earth PE Main circuit breaker 63 A maximum 3 phase plus neutral N Short circuit rating 10 kA 400 V or 20 kA 230 V Norm IEC 60947 2 Provided with a ground fault current interrupter of 300 mA Output connectors Three 19 pins circular multi pole connectors with each 6 circuits Each circuit is protected with a 16 A switch fuse 20 kA short circuit rating Three 2 phase plus protective earth auxiliary connectors
12. r connector Connect the other side of the multi power cable with one of the multi pole sockets on the rental power box Ensure to fasten the locking cap of the multi pole plug Warning Ensure the rental power box is switched off Repeat from step 1 until all multi pole sockets of the rental power box are used R5976615 RENTAL POWER BOX 14052004 4 Physical installation 12 85976615 RENTAL POWER BOX 14052004 A Addendum A ADDENDUM A 1 Identification system of a power distribution network according IEC 364 TT IT TN C and TN S The first character indicates the position of the neutral conductor Directly connected with the protective earth Isolated from the protective earth or connected through an impedance The second character indicates the grounding manner of electrical equipment T Directly connected with the protective earth N Connected with the neutral conductor of the power source The third character indicates the situation of the neutral N conductor and the protective earth PE conductor Common conductor for neutral and protective earth e S Separated conductors for neutral and protective earth A 2 Diagrams Internal wiring diagrams Phase Selector Switch 220V 400V 63A Power meter PM500 pe 12 L3 N3 Image A 1 1 Inter
13. software as well as to other services provided by Barco being a component of the system or independent service will be deemed invalid provided the damage is not proven to be attributed to the absence of properties guaranteed in writing or due to the intent or gross negligence or part of Barco If the purchaser or third party carries out modifications or repairs on goods delivered by Barco or if the goods are handled incorrectly in particular if the systems are commissioned operated incorrectly or if after the transfer of risks the goods are subject to influences not agreed upon in the contract all guarantee claims of the purchaser will be rendered invalid Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser e g interfaces Normal wear as well as normal maintenance are not subject to the guarantee provided by Barco either The environmental conditions as well as the servicing and maintenance regulations specified in the this manual must be complied with by the customer Changes Barco provides this manual as is without warranty of any kind either expressed or implied including but not limited to the implied war ranties or merchantability and fitness for a particular purpose Barco may make improvements and or changes to the product s and or the program s described in this publication at any time without notice This publication could con
14. switch fuses at the front side Image 4 1 Mains Input connector B Padlockable phase selector switch C Multi pole output connectors D Auxiliary output connectors Front side At the front side are the main circuit breaker and the switch fuses of each output circuit accessible The front side also contains the display of the power meter The number and the color of the switch fuses correspond with the number and color of the output connectors at the rear side Image 4 2 A Main circuit breaker B Power meter C Switch fuses for output circuits R5976615 RENTAL POWER BOX 14052004 9 4 Physical installation 4 2 Set up of the rental power box This rental power box can only be used on a TT or TN power distribution network Do not use this power box with an IT power distribution network A neutral conductor must be provided In case of using this power box with a power generator make sure that the centre point of the power generator is connected to the earth How to set up the rental power box 1 Place the rental power box in a safe and dry location which is only accessible by authorized persons 2 Lock the wheels of the flight case and remove the front and rear cover 3 Place all the switch fuses in the OFF position 4 Place the padlockable phase selector switch on the matching phase to phase voltage of the local power network Warning Make sure to select the correct mains voltage Wrong selection can cause dama
15. tain technical inaccuracies or typographical errors Changes are periodically made to the information in this publication these changes are incorporated in new editions of this publication Trademarks Brand and product names mentioned in this manual may be trademarks registered trademarks or copyrights of their respective holders All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufactures Table of contents TABLE OF CONTENTS LENITER 3 14 Important Safety Instructions liabet tot ks kunda aida Jul teste bL bte kc tK Ue 3 1 2 Important Warnings Mee ra pete 3 2 Introduction ur rca n Q a sa RR A a ADD AA E ERR ARR 5 2 1 General functionality 5 er ea arena LRL dish RE RERUM MN adds eee ANIMI NR AE 5 2 24 Order info rental power DOX irsi ciet kaka py eR decide pert ne PvE cheats edhe ed ak Aya xbv np 5 2 9 Technical summaty err pre Mee i AE aal onde goats PER IUE QUI TER UE EM Dui wate ed guess PO 5 3 Cables used with the rental power 001 7 3 1 Order info power cables ge o Aule REL EAM a UI