Home
Multi Layer Line Control - Sysmetric. Simply accurate.
Contents
1. Figure 3 5 4 Model screen Monitor 1 RPM the R P M of the extruder in percentage 2 Output the output of the extruder in Kg h 3 Reject minimum time delay between adjacent batches If a second batch is processed before this time has elapsed the system will temporarily disable the control and will preset the batch Counter to 4u 4 Counter batch counter that represents the system stability The system is considered stable when the counter 15 at zero 5 Last cap the last estimated extruder s capacity in gram per revolution It is calculated in relative units denoted by z The Last cap 1s compared to the min and max levels after every batch and if exceeds the Counter is preset to 4u Such an event occurs usually after interference in the material flow and it stops the values updating until the line stabilizes again Average cap the final filtered value of the extruder s capacity 7 S D the standard deviation of the screw capacity values in percentage units www sysmetric ltd com 19 Line Control 5 Layers with CD User Manual Setup 1 Max cap the maximum allowed value for the Last cap parameter 2 Min cap the minimum allowed value for the Last cap parameter 3 Reject Set the set value for the Reject timer www sysmetric ltd com 20 Line Control 5 Layers with CD User Manual 3 6 Mo
2. the maximum RPM of each extruder 2 Extruder Pressure Alarm the pressure at which the system will alarm 3 Extruder Pressure Stop the pressure at which the system will stop the extruder www sysmetric ltd com 17 Line Control 5 Layers with CD User Manual 3 5 2 IBC Tuning Screen The IBC tuning screen holds parameters for the IBC control To enter this screen press the LINE SERVICE button on the control display and then press JBC Control Bed un See the ABC user manual for details on the IBC parameters Figure 3 5 3 IBC Tuning screen www sysmetric ltd com 18 Line Control 5 Layers with CD User Manual 3 5 3 Model Screen The system uses control technique called modeling The modeling technique is a special control technique that enables stable and accurate control It 1s based on the actual terms involved in the process as opposed to the general control techniques PID etc The idea of the modeling technique is to evaluate the mass per revolution that the extruder screw pumps The model evaluation is capable of handling the screw nonlinearity as well All calculations are carried out in natural controller numbers rather than physical terms in order to obtain full accuracy for this reason some of the values will use z units To enter the model screen press the LINE SPEED button on the control display and then press MODEL Kg hr O A Kohr 8 8 Kohr 8 8 Kg hr Sl Pe Se
3. i m me edt 16 3 5 3 Model SCr Cn 0 ccc cccccccececnccccccucucuccececscscucucsccscecscecucucuceseecsctcucesesacs 19 3 6 MOTOR S TATUS OCR EEN ox 21 SN ALARMS SCRIE eio reo eT uet Spei onini ete pedes 22 4 PRODUCTION STABILITY AND 23 4 1 CD WEIGHING BUCKET LOADCBELL eene eene nemen 23 4 2 CD NIXER INEEEPROXIMITY 23 4 3 CD MIXER ROTATION PROXIMITY SWITCH 23 4 4 ROW MATERACE SUPPLY a D EIE Ed 23 4 5 BATCH PREPARATION PROCESS 24 4 6 iei a er Se Ad UM Les ED OAM CON MM DOLES DO ene er ee 24 4 7 SCREW CAPACITY OUT OF RANGE 24 www sysmetric ltd com Line Control 5 Layers with CD User Manual 1 Introduction 1 1 Blown Film Extrusion Blown film extrusion is the process of extruding plastic through a circular die and blowing the melted plastic into a bubble like expansion The bubble is pulled upwards until it passes through a nip roll where it is flattened to create what is known as lay flat of blown film At the end of this process the lay flat is winded on reels Extruding the plastic through the die can be done using several extruders in order to manufacture multi layer films with each layer being made from different materials with
4. calibration cage and the IBC system to produce the desired lay flat width ABC system e Temperature control over the temperature of the extruders and the die www sysmetric ltd com 4 Line Control 5 Layers with CD User Manual 2 System Overview 2 1 Control Panel o Q Q S EMERGANCY STOP Figure 2 1 1 Control panel The control panel of the system consists of the following Control voltage lamp indicates power supply Alarm silent push button for muting the alarm bell Extruders on off switch Nip roll on off switch and open close push button Nip rotation on off switch Air ring blower on off switch and speed control potentiometer IBC intake blower on off switch and speed control potentiometer Bubble cage open close and up down push buttons Line control switch to select control mode Emergency stop push button Auto pilot stages push buttons 0 I IIT IV Touch screen display for programming and monitoring www sysmetric ltd com 5 Line Control 5 Layers with CD User Manual 2 2 Control Display a i a rrr d ale s alea a a Figure 2 2 1 Control display The control display is a color touch screen panel Every operation on the display is carried out by pressing gently on the display Activating a button is carried out by pressing gently on the display where the button is drawn Changing numeric values is carried out by pressing
5. enter this screen press the DOSING button on the control panel 0 0 To set the dosing formula press the Extruder label open the formula screen enter the desired dosing formula for the specific extruder ensure that the Total is 100 0 and press Replace Formula to activate the new formula Figure 3 3 1 Dosing screen Figure 3 3 2 Extruder formula screen See the CD Series user manual for more details on the dosing formula www sysmetric ltd com 12 User Manual Line Control 5 Layers with CD Total Screen The total screen shows the amount of raw material that was dispensed at each channel of each dosing unit for each extruder To enter this screen press the Total button on the control panel 3 4 _ C c c3 c 23 _ c fs ee ee Mm ae a r c c c exem ee C C S C erem c cS co Figure 3 4 1 Total screen Press the RESET button to reset the accumulators 13 www sysmetric ltd com Line Control 5 Layers with CD User Manual 3 5 Line Service Screen The line service screen is used for setting and monitoring parameters of the line s speed and selecting spe
6. 3 B4 85 uan sv PV ExC les m ge Ex D M SV PV CD AL Figure 3 2 1 Line temperature screen 3 2 1 Quick Heat The buttons on the right side of the temperature screen enable quick adjustment of the temperatures Pressing these buttons will set all the temperatures to the preset value the preset values are determined in the General line service screen Pressing the OFF button will turn off all of the heaters Pressing the Profile button will set each zone to its working temperature www sysmetric ltd com 10 Line Control 5 Layers with CD User Manual 3 2 2 Extruders and Die Temperature Screens The extruders and the die temperature screens show extra data on the heaters SV the set temperature PV the actual temperature Eff the working ratio of the heater Amps the current that is driven to the heater A Amps the maximum allowed current A higher current will cause the system to alarm BONONIE UNUS ea 5 Figure 3 2 2 Extruder temperature screen a LINE SERVICE Figure 3 2 3 Die temperature screen www sysmetric ltd com 11 Line Control 5 Layers with CD User Manual 3 3 Dosing Screen The dosing screen shows the set dosing formula for each extruder and the actual formula according to the last batch that the system prepared To
7. Blown Film Extrusion Line Control 5 Layers CD Series IBC Temperature USER MANUAL Sysmetric 1122 Afula 18550 Israel Tel 972 4 6405857 Fax 4972 4 6405911 info sysmetric Itd com www sysmetric ltd com Manual Number 5CDIT102 January 2010 Line Control 5 Layers with CD User Manual Table of Contents 1 INTRODUCTION 203 eea aeaee eaae aaae 3 1 1 ee 3 1 2 EINE 3 1 3 THS VAIN 4 2 SYS PEM OVER Y IBN x iie esee e tvn Ea Re 5 2 1 CONTROL I DII LI S MR ID ee 5 232 CON ROCD TEA ieee D a EE 6 Z2 NUINCTIC Valle Susssontidintet esum eid inrita Reid T aid 6 Dis CD SERIES GRAVIMETRIC DOSING 8 7 3 MONITOR AND CONTROL SCREENG ccccsccscccccccccccccscccces 8 3 1 EINE SCREEN oA T E ETE T 8 3 2 LINE TEMPERATURE SCREEN ccccsccscsscscscucescssescecesceseusescsescusesceseess 10 Ids QUICK Heal 10 3 2 2 Extruders and Die Temperature Screens 11 323 DOSING SCREEN Sse eee 12 3 4 TOTAL de ae ea an de nae DE E Dd Or OE 13 3 5 LEINE SER VICE SCREEN 14 Shs Ganera SSCFOOIL a eben 16 9 945 ABC TUNNE SCFC eodein ei
8. ation The control unit of the CD doser combines automatic adaptive tuning and noise filtering algorithms with the ruggedness open architecture and extensibility of an industry standard PLC The CD Series dosing units are divided to 5 models for different capacities CDIOO for up to 100Kg h 0400 for up to 400Kg h CD800 for up to 800Kg h o CD 800HD200 for up to 1000Kg h o CD 800HD400 for up to 1200Kg h Note the stated capacities refer to granulated material with 0 5 Liter Kg density and may vary with different materials The Line Control operation principles are the same for all CD models and this manual refers to all models For detailed information on the CD Series dosing units operation and maintenance please refer to Sysmetric s CD Series user manual www sysmetric ltd com my Line Control 5 Layers with CD User Manual 3 Monitor and Control Screens 3 1 Line Screen The line screen is the main screen of the system This screen shows the extruders status and the production parameters Press the LINE button to switch the display to the line screen Lim amp om ur um im 0 g 5 T 2n Mint Width Melt Temp id CIS Figure 3 1 1 Line screen The line screen shows the following data e For each extruder Ex A Ex D Ex C Ex D Ex o SET and ACTUAL output as percentage of the total line throughput o Kg hr The output by Kg hr o RPM The extruder s RPM o LOAD T
9. different properties The bubble size in the blown film extrusion is dependent on the amount of air introduced into the bubble and the position of a calibration cage if exists The air inside the bubble can be continuously exchanged by what is known as IBC Internal Bubble Cooling system Cooling the air inside the bubble helps cooling the plastic faster and thus enables increasing the production throughput Manufacturing film by this process gives the ability to regulate the film s width and thickness by controlling the volume of air inside the bubble the output of the extruder and the speed of the nip roll 1 2 Line Control Sysmetric s Line Control systems are designed to control the different sub systems involved in the blown film production line in order to manufacture the film with the desired properties The different sub systems and controls are Raw material handling can be carried out by one of two systems Graviman loss in weight follow up on the extruder throughput o CD Series batch type gravimetric dosing units for preparing defined mixtures of raw material The extruder s throughput is determined and monitored by the batch preparation rate Material handling can also include conveying the raw material to the Graviman CD and to the extruder e Extruder controlling the extruder speed RPM BC and calibrator cage controlling the air exchange inside the bubble and the calibrator position
10. ed calibration mode Press the LINE SERVICE button on the control display to switch to the line service screen The system will request the access password The password 15 4321 won wr Lud Figure 3 5 1 Line service screen Set Speed Data 1 Ramp rate defines the time in seconds for ramping the production throughput from 0 to 100 2 Length pulse distance the circumference in millimeters of the roll where the digital speed proximity switch is installed 3 Length pulse per Rev the number of pulses that the digital speed proximity switch generates per one revolution of the roll where it is installed 4 Automatic start speed the minimum start speed of the nip roll This value is used by the control to start the nip roll when the production is in automatic mode Actual Speed Data 1 Maximum speed 1s the calculated maximum line speed This value is calculated based on the speed calibration 2 Analog speed the current line speed according to the analog input 3 Digital speed 1s the calculated line speed according to the digital pulses This value 1s averaged over 30 seconds and thus it 1s accurate only when the line speed has not been changed for at least 30 seconds 4 S d speed the standard deviation of the line speed in percentage units This value is calculated when the line is in automatic calibration www sysmetric ltd com 14 Line Control 5 Layers with CD User Manual Auto Ca
11. ely high more than 4 and the gram per revolution value Last cap will be instable 4 7 Screw Capacity Out of Range If the value of Last cap is out of range or close to the minimum or maximum levels please consult Sysmetric support www sysmetric ltd com 24
12. gently on the display where the value is written 2 2 1 Entering Numeric Values Several screens e g LINE screen have one or more editable numeric items e g the percentage of each layer To modify the value of an item carry out the following 1 Select the item that you want to edit by pressing gently on the display where that item appears A pop up screen with numeric keypad will appear on the display 2 Enter the new value using the numeric keypad If the item has a decimal point use the key to move to the fractional part For example to enter 12 3 press 1 727 followed by 3 3 Press the Enter key to confirm the change The keypad screen will close and the item will receive the new value Cancel editing by pressing the X button in the keypad screen Figure 2 2 2 Numeric keypad www sysmetric ltd com 6 Line Control 5 Layers with CD User Manual 2 3 CD Series Gravimetric Dosing Units The CD Series gravimetric dosing units are Sysmetric s solution to raw material dosing for extrusion and injection molding processes The CD doser reduces material cost utilizing its high accuracy to lower the amount of expensive additives in the product The batch weighing nature of the doser offers calibration free operation and up to the gram accumulation of raw material flowing through the system The mechanical simplicity of the CD series units and its practical design ensures easy maintenance free oper
13. he extruders motor LOAD shown in Amps or in percentages relatively to the maximum amps of the motor o Melt Temperature and Melt Pressure Set and actual WEB WIDTH and BUBBLE GAP Set and actual WEB THICKNESS and its calibration Factor Kg hr and THICKNESS for the Auto pilot stages I III IV Production parameters o Line speed by m min o Web s gram per meter by gr m o Line s throughput by Kg hr e Scanner On Off Web s thickness scanner control optional www sysmetric ltd com L8 Line Control 5 Layers with CD User Manual Control buttons on the line screen when the line control is in manual mode Ex Start Stop start and stop the extruder Ex increase and decrease the extruder s speed Control buttons on the line screen when the line control is in group mode Output increase and decrease the line s output Control buttons on the line screen when the line control 15 in automatic mode e Speed increase and decrease the line s speed nip roll speed www sysmetric ltd com 9 Line Control 5 Layers with CD User Manual 3 2 Line Temperature Screen The line temperature screen is used for setting and monitoring the desired and the actual temperatures of the extruders the die the IBC air and the cooling air ring Press the LINE C button to switch the display to the temperature screen EXATAT TA TAS DA LAS CID A Met EU Ring SV PV Ex B 8
14. libration The control system uses the analog speed for calculating the extruders speed in order to maintain the desired film s Kg M The analog speed calculated from the nip roll s motor driver reference voltage tends to vary with time and does not maintain stability When the system is set to automatic calibration mode it uses the digital speed sensor to continuously calibrate the analog speed thus maintaining the correct extruder speed and correct Kg M To enable automatic mode press the AUTO CALIBRATE push button in the control display The label next to the push button will display to indicate automatic mode Pressing the button again will disable the automatic mode Speed Calibration 1 Auto Cal Range defines the allowed range of automatic calibration 2 Manual Calibrate manually calibrating the line speed This calibration can only be carried out when the automatic calibration is disabled There are two ways to manually calibrate the line speed a Measure the actual line speed with a measuring device and enter that value in the Manual Calibrate field b Copy the Digital speed value to the Manual Calibrate value www sysmetric ltd com x15 Line Control 5 Layers with CD User Manual 3 5 1 General Screen The general screen holds general parameters of the line operation To enter this screen press the LINE SRVICE button on the control display and then press General Figure 3 5 2 General screen Hou
15. n the Last cap parameter should be stable it should be approximately twice the Min cap value and approximately half the Max cap value and it should be close to the Average cap value In addition the S D should be lower than 4 Monitoring these values for several consecutive batches will provide all the data necessary to locate any problem If the Last cap value is not stable and or the 5 0 15 relatively high more than 4 check the following 4 1 CD Weighing Bucket Loadcell 1 Clean the weighing bucket loadcell of the CD dosing unit 2 Check if the loadcell is connected tightly to the housing 3 Check if the weighing bucket is calibrated See Calibration chapter in CD Series user manual for more details 4 2 CD Mixer Inlet Proximity Switch 1 Stop the CD dosing unit 2 Open the weighing bucket service door on the CD mixer chamber and check that the proximity switch is free of dirt 3 Define the type of proximity switch installed in the system by checking its color and act accordingly e For orange Proximity Switch i Turn the sensitivity screw located at the back of the proximity switch clockwise until the indicator LED turns off Turn the sensitivity screw counterclockwise slowly until the indicator LED turns on ii Turn the screw counterclockwise half a turn more e For yellow Proximity Switch i Turn the sensitivity screw located at the back of the proximity switch clockwise until the indicator LED turns on Tu
16. r Counters 1 Extruder the total working hours of each extruder 2 Line the total working hours of the line 3 Vacuum Pump the total working hours of the vacuum pump Oscillating Table Oscillating Table Rotation Time defines the time to complete one rotation of the oscillating table Temperature 1 Temperature Range range of temperature around the set temperature that 15 considered normal When the extruder s actual temperature exceeds this range the system will indicate a too low temperature by a blue color on the temperature label or too high by a red color on the temperature label 2 Minimum Extruder Temperature the minimum temperature for activating the extruder 3 Minimum Extruder Soak Time the minimum time that the extruder is at the Minimum Extruder Temperature or higher temperature before allowing activating the extruder Minimum Die Temperature the minimum temperature for activating the die Minimum Die Soak Time the minimum time that the die is at the Minimum Die Temperature or higher temperature before allowing activating the line 6 Maximum Cabinet Extruder Temp the temperature to alarm on high temperature at the cabinet of the extruder s motor drivers oe www sysmetric ltd com 16 Line Control 5 Layers with CD User Manual 7 Temp Profile define the temperatures for the quick heat in the temperature screen Extruders 1 Extruder Max RPM
17. rn the sensitivity screw counterclockwise slowly until the indicator LED turns off ii Turn the screw counterclockwise one more turn 4 3 CD Mixer Rotation Proximity Switch Monitor the CD mixer rotation proximity switch to verify it works properly 1 While the production line and the CD unit are on verify that when the mixer rotates the sensor s indication light is blinking 2 Verify that the mixer is constantly stopping at the same angle 4 4 Raw Material Supply Check if the raw material supply to the CD unit is ok There should always be material in the hopper loaders of the CD when batches are prepared otherwise the batch preparation process can become too long and the supply continuity can be www sysmetric ltd com pod Line Control 5 Layers with CD User Manual damaged However one raw material supply problem in 10 minutes is still acceptable and will not disturb the stability and the accuracy 4 5 Batch Preparation Process Time Batch preparation process in the CD unit should always be shorter than 1 minute If the process is longer than minute monitor the CD unit and identify the cause of delay 4 6 Batch Size If the batch size of the CD unit 15 too small it causes the batches to be supplied from the dosing unit to the extruder in pairs and that can disturb the control process When it happens the interruption counter Counter of the system is preset to the value 4u standard deviation S D will be relativ
18. to form the desired width of lay flat e Nip roll tuning the nip roll speed for the desired Meter Minute e Tension and Winder adjusting the tension rolls and winder speed to tense the lay flat and wind it on the reels Temperature controlling the temperature of the extruder the die and the tension rolls e Remote control setting parameters to the production line and data acquisition from a remote PC Minuman software www sysmetric ltd com 3 Line Control 5 Layers with CD User Manual By controlling and monitoring these sub systems the Line Control can ensure film production with specific properties of e Width e Thickness gram per meter Layers Ratio in multi layer production lines The different models of Sysmetric s Line Control systems involve different combinations of the above mentioned sub systems of the production line and can control part or all the parameters of the blown film extrusion 1 3 This Manual This manual describes Sysmetric s line control system for blown film production lines which involves the following e 5 CD Series gravimetric dosing units the CD model is selected to fit the production line throughput e Control on the speed of the 5 extruders e Layers ratio adjusting the relative speeds of the extruders to receive the desired layers ratio Thickness adjusting the extruders speed to receive the desired film s thickness e Width control over the
19. tor Status Screen The motor status screen shows the line s motor drivers alarms The screen shows active alarms if exists and recent alarms memory alarms Press the Motor Status button on the control display to switch to this screen Figure 3 6 1 Motor Status screen www sysmetric ltd com 21 Line Control 5 Layers with CD 3 7 Alarms Screen User Manual The system creates an alarm log Press the ALARM button on the display to switch to the alarm log screen 408 2B MAB PA D2DIDIDIDI ddd PEEN M melos 43 4 3 2006 27 26 PM 2 27 19 PM 04 03 2006 03 26 58 04 03 2006 03 27 04 PM eneral Fault In Extruder one Al General Fault In Extruder B Zone Nip Dr iye jesse F 2 Dosing per empty ruder D ump Pressure Swi Dosing C Low pos n PLC osing Dosing de iron chl 82 Do T m AMA error Dosing A Bad Conveying Ch 1 Figure 3 7 1 Alarms screen The alarm log shows which alarms were active and the start and end time of each alarm www sysmetric ltd com 22 Line Control 5 Layers with CD User Manual 4 Production Stability and Accuracy The control on the extruder throughput relies on the known size batches of raw material supplied to the extruder continuously by the CD dosing unit During Operation every time a batch of raw material is supplied to the extruder the Last cap is updated In normal operatio