1. IEEE 488 5 V PCI Maximum data rate More than 900 KB s Buffering Built in Configuration Plug and play EMC and safety IEC 61326 1 Group 1 Class A IEC 61010 1 Warranty 1 year Dimensions Length width and height 122 mm L x 122 mm W x 22 mm H a full height PCI card Weight 0 091 kg Environmental Specifications Operating environment 0 C to 55 C Operating humidity Up to 90 at 40 C non condensing Storage environment Up to 90 at 65 C non condensing Additional detail and information in the Declaration of Conformity Agilent 82351A PCle GPIB Interface Card Features Compact half height size 68 9 mm e High transfer rate of 1 4 MB s e High flexibility via up plugging to x4 or x8 PCle slots e 3 3 V signal level for lower power consumption Compatibility with industry standard PCle rev 1 0a and IEEE 488 e Interface to 14 GPIB instruments max Best for e Bandwidth intensive PC applications e Adding GPIB connection for PCle based PCs or workstations High transfer rate for demanding test applications The Agilent 82351A PCle GPIB interface card is designed for integration into next generation PCs or workstations It offers fast data transmission for various demanding test applications that require data to be transferred to memory fast enough without any loss or overwriting PCle PCI Express is an evolutionary version of PCI that off
2. PCI and PCle e Compatibility with instruments and software from different vendors with the industry standard VISA 1 0 libraries Agilent connectivity software helps you establish a connection in less than 15 minutes The Agilent I0 Libraries Suite eliminates the many working hours it takes to connect and configure PC controlled test systems This connectivity software ships with each Agilent connectivity product and over 150 Agilent test and measurement instruments Connecting your instruments to a PC is as easy as connecting a PC to a printer even if you use multiple instrument vendors Now the enhanced version 15 0 or higher is with expanded compatibility with other vendors connectivity software You can now use any programming API with any standard T amp M software development environment Simply install Agilent s 10 Libraries Suite on your PC then cable the interfaces and instruments to your PC The IO Libraries Connection Expert utility will find the interfaces and instruments connected to your computer and configure them properly Agilent 10 Libraries Suite 15 0 or higher Summary of requirements e Microsoft Windows 2000 SP4 XP SP2 Vista note only supported with version 15 0 or higher 98 SE ME note only supported with version 14 0 Windows 7 supported with version 15 5 or higher e Microsoft Internet Explorer 7 or higher 800 MHz Intel Pentium processor 1 GHz 32 bit recommended for Vista and Windows 7 e 8
3. 00 x 600 display with 256 colors and supports DirectX 9 graphics e 256 MB RAM 1 GB or greater is recommended e 1 5 GB total hard disk space e Supported APIs include Agilent or NI VISA SICL VISA COM and NI 488 2 If you already own an Agilent connectivity product or instrument you can download the latest version of Agilent 10 Libraries Suite for free Agilent 82357B USB GPIB Interface Features e Fast and easy connection to GPIB instruments e Uses standard USB and IEEE 488 interfaces e Maximum GPIB transfer rate of more than 1 15 MB s e Use industry standard software e Parallel polling capability Best for e Easiest GPIB connectivity e Notebook computer GPIB connections Connect GPIB instruments quickly and easily to your computer s USB port The Agilent 82357B USB GPIB interface provides a direct connection from the USB port on your desktop and laptop computers to GPIB instruments Once the software is loaded your computer automatically detects the 82357B when it is connected to the USB port of the computer The 82357B is a plug and play device It is also hot pluggable making it easy to connect and disconnect without having to shut down the computer No external power supplies are necessary The 82357B USB GPIB interface implements USB 1 1 12 Mbits s and is compatible with USB 2 0 The 82357B USB GPIB interface uses a thin flexible high quality USB cable that is USB 2 0 compliant The USB cable is sh
4. 32 baud rates 300 1200 2400 4800 9600 19200 38400 57600 115200 230400 b s RS 232 flow control None RTS CTS XON XOFF DTR DSR RS 232 parity None Odd Even Space Mark RS 232 bits 5 6 7 8 RS 232 stop bits 12 RS 232 SRQ interrupts on RI DSR DCD CTS using connectivity libraries Maximum instrument connections 4 RS 232 instruments devices Configuration Plug and play Indicators Tri state LED displays device status and COM port activity EMC and safety CISPR 22 Class B CISPR 24 IEC 60950 Warranty 1 year Dimensions Length width and height 111 mm L x 183 mm W x 26 mm H Weight 0 311 kg Environmental Specifications Operating environment 0 C to 55 C Operating humidity Up to 90 at 40 C non condensing Storage environment 40 C to 70 C Storage humidity Up to 90 at 65 C non condensing Additional detail and information in the Declaration of Conformity Agilent E5813A Networked 5 Port USB Hub Features e Interface a variety of GPIB RS 232 and USB devices to complete your test system e Extend USB devices beyond five meters e USB ports appear to be locally attached and are locked to one computer Best for e Remote access to USB port devices or instruments Connecting remote USB GPIB or RS 232 instruments or devices via a standard LAN The Agilent E5813A networked 5 port USB hub uses LAN
5. Agilent Connectivity Hardware for PC to Instrument Connections Data Sheet GET A soKen with Agilent GPIB and Instrument Control Products EE Agilent Technologies e Choose the best way to connect your PC to GPIB USB and RS 232 instruments e Take advantage of standard PC interfaces USB LAN PCI e Protect your investment with industry standard connectivity software Table of contents 82357B USB GPIB Interface 3 82350B High Performance PCI GPIB Interface 82351A PCle GPIB Interface E5810A LAN GPIB Gateway E5805A USB 4 Port RS232 Interface 7 E5813A Networked 5 Port USB Hub 8 aon e Cables and Adapters 9 Choosing a remote connection 9 Ordering information 10 Related Agilent literature 10 Easily Connect your PC to GPIB USB and RS 232 instruments Connecting your PC to test instruments has become easier than ever before The Agilent connectivity hardware product family is designed to provide you a variety of interfaces and to simplify the connection The connectivity products featured in this data sheet will help you connect your current instruments with GPIB or RS 232 interfaces to your PC with ease Agilent Connectivity Software With Agilent GPIB and Instrument Control Products you can be assured of e Fast easy and rock solid connections to a wide range of instrument interfaces GPIB USB and RS 232 e Easy instrument connection to a variety of PC standard interfaces USB LAN
6. C 0 7 AMPS Power line frequency 50 to 60 Hz Output 5 V DC 3 AMPS max USB device power available 500 mA per device Connectors Maximum data rates LAN RJ 45 Standard USB A on each of the 5 ports 12 Mbps from each port Maximum instrument connections 5 USB instruments or devices Configuration Remote LAN configuration utility Indicators LEDs for system and device status EMC and safety CISPR 22 Class B CISPR 24 IEC 60950 ITE equipment intended only for use with ISM equipment Warranty 1 year Network and Device Recommendations IP addresses One IP address per unit E5813A device sharing Locked to one computer at a time One computer must release the E5813A before another computer can use it Network utilization Maximum network utilization below 50 Compatibility Compatible with bulk or interrupt type USB devices isochronous devices are not supported Dimensions Length width and height Device 112 mm L x 182 mm W x 26 mm H Power adapter 110 mm L x 60 mm W x 35 mm H Weight Device 0 284 kg Power adapter 0 25 kg Environmental Specifications Operating environment 0 C to 55 C Operating humidity Up to 90 at 40 C non condensing Storage environment 40 C to 70 C Storage humidity Up to 90 at 65 C non condensing Additional detail and informati
7. e only Warranty 1 year Dimensions Width depth and height 120 8 mm W x 158 0 mm D x 21 6 mm H Weight 0 082 kg Environmental Specifications Operating environment 5 C to 60 C Operating humidity Up to 90 at 40 C non condensing Storage environment 40 C to 70 C Storage humidity Up to 90 at 65 C non condensing Additional detail and information in the Declaration of Conformity Agilent E5810A LAN GPIB Gateway Features e Remote access and control of GPIB instruments via the LAN e Easy setup and use via digital display and web browser Best for e Connection to remote GPIB and RS 232 instrumentation e Shared test systems Remote access and collaboration with GPIB instruments via your LAN The E5810A can use DHCP if available to automatically configure necessary network parameters including its IP address The gateway can be controlled from multiple locations and by multiple users via your LAN so it is easy to share control of instruments from locations worldwide For easy remote access enter the IP address from the digital display as the URL in your web browser and gain access to connected GPIB and RS 232 instruments Then use your browser to send instrument commands interactively and quickly see your measurement results Use the digital display and LEDs to check the IP address and troubleshoot locally With 10 Libraries Suite 15 0 or hig
8. ers a higher transfer rate across a low number of wires It is also backward compatible with PCI software so you don t need to perform any code re configuration The powerful bus architecture of PCle allows bi directional data transmission and the implementation of a new class of test applications New standard for high speed internal devices 82351A Technical Specifications General Requirements Minimum system requirements Windows 2000 XP Vista Windows 7 Software required Agilent I0 Libraries Suite included 450 MHz Pentium II 1 GHz 32 bit recommended for Vista and Windows 7 256 MB RAM 1 GB or greater is recommended for Vista and Windows 7 1 5 GB free disk space 1 GB for Microsoft NET Framework 2 0 and 65 MB for Agilent I0 Libraries Suite is recommended PCI bus slot 3 3 V PCle slot 32 bits Supported standards PCle rev 1 0a IEEE 488 1 and IEEE 488 2 compatible General Characteristics Power Backplane 3 3 V PCle Connectors Standard 24 pin IEEE 488 1 5 V PCle Maximum data rate Maximum instrument connection Buffering 1 4 MB s or better 14 instruments daisy chain via GPIB Built in Configuration Plug and play EMC and safety IEC 61010 1 2001 EN61010 1 2001 Canada CSA C22 2 No 61010 1 2004 IEC 61326 2002 EN61326 1997 A1 1998 A2 2001 A3 2003 Pollution Degree 2 This product is rated for indoor us
9. her you are able to program the instruments in all standard development environments System use For system environments the E5810A gateway can be mounted on a rack The rack mount kit Option 100 allows two devices to be placed side by side in one rack width With its built in power supply there are no additional power modules to mount TE Agilent Technologies ESSIOA oun Take advantage of sete LAN technology for To 8 jG your GPIB instruments and test systems a i E5810A Technical Specifications General Requirements Minimum system requirements Available 10BASE T 100BASE TX LAN port client computers Windows 2000 XP Vista Microsoft Internet Explorer 5 01 or higher Microsoft Internet Explorer 7 or higher for Vista Operating system Supported web browser Web browser or for programmatic control Agilent 10 Libraries Suite included see requirements on page 2 Software required IEEE 488 1 and IEEE 488 2 compatible 10BASE T 100BASE TX networks VXI 11 protocol EIA 232 Supported standards General Characteristics Power supply 100 240 V 10 Power consumption 7 watts 25 VA peak Power line frequency 47 to 63 Hz Connectors Std 24 pin GPIB IEEE 488 RS 232 9 pin LAN RJ 45 Maximum data rates More than 900 KB s GPIB port 115 Kb s RS 232 port RS 232 baud rate 300 1200 2400 4800 9600 19200 38400 57600 115200 b s RS 232 flow contro
10. ielded and the connector is specified to 1 500 insertions ensuring a durable connection and reliable data transfer Boosting performance with simplest connectivity 82357B Technical Specifications General Requirements Minimum system requirements Windows 2000 XP Professional Vista Windows 7 450 MHz Pentium II 1 GHz 32 bit is recommended for Vista and Windows 7 256 MB RAM 1 GB or greater is recommended for Vista and Window 7 1 5 GB free disk space 1 GB for Microsoft NET Framework 2 0 and 65 MB for Agilent 10 Libraries Suite is recommended USB port OS and Microsoft NET Framework may require more resources Supported standards Supports USB 2 0 high speed and full speed Standard USB endpoints supported IEEE 488 1 and IEEE 488 2 compatible SICL and VISA 2 2 Unsupported GPIB modes of operation Pass Control e Non System Controller mode General Characteristics Power USB bus powered device 5 V 500 mA max 200 mA typ GPIB transfer rate 1 15 MB s or better Connectors Standard 24 pin IEEE 488 Standard USB A USB hubs Self powered hubs Parallel polling A single parallel poll can easily check up to eight individual devices at once corresponding to the number of data lines on the GPIB Cable 2 5 meters shielded connector rated for 1 500 insertions LED indicators READY ACCESS FAIL Maximum connections Maximum of 4 co
11. l None RTS CTS XON XOFF DTR DSR RS 232 parity None Odd Even Space Mark RS 232 bits 5 6 7 8 RS 232 stop bits 1 2 RS 232 SRQ interrupts on RI DSR DCD CTS Max instrument connections 14 instruments daisy chain via GPIB 1 RS 232 device Up to 16 simultaneous connectivity connections Indicators LEDs for Power Activity Fault EMC and safety IEC 61326 1 Group 1 Class A IEC 61010 1 Warranty 1 year See the E5810A User s Manual for supported network protocols and functions Network protocols Dimensions Width depth and height 211 mm W x 230 mm D x 41 mm H 1U height 1 2 rack Weight 1 6 kg Environmental Specifications Operating environment 0 C to 55 C Operating humidity Up to 90 at 40 C non condensing Storage environment 40 C to 70 C Storage humidity Up to 90 at 65 C non condensing Additional detail and information in the Declaration of Conformity Agilent E5805A USB 4 Port RS232 Interface Features e Easy connection from standard USB port on your PC to up to four RS 232 instruments or devices e Fully compatible with Windows COM driver and industry standard VISA 1 0 software Best for e Easy connection to RS 232 devices e RS 232 connection to a notebook computer Add four serial ports within minutes The Agilent E5805A USB 4 port RS 232 interface provides a direct connection from the USB port on your noteb
12. nverters can be connected to the PC Instrument connections 14 instruments daisy chain via GPIB Configuration Plug and play Warranty 1 year EMC and safety e IEC 61010 1 2001 EN 61010 1 2001 e Canada CSA C22 2 No 61010 1 2004 Dimensions Length width and height 105 mm L x 64 mm W x 30 mm H including connectors Weight 215 grams Environmental Specifications Operating environment 0 C to 55 C Operating humidity Up to 90 at 40 C non condensing Storage environment 40 C to 70 C Storage humidity Up to 90 at 65 C non condensing Additional detail and information in the Declaration of Conformity Agilent 82350B High Performance PCI GPIB Interface for Windows Features e PCI IEEE 488 interface for PCs e Transfer rates up to 900 KB s e Dual processor support on Windows 2000 XP Best for e Maximum GPIB throughput for all configurations High performance for manufacturing test applications The 82350B is Agilent s highest performance GPIB interface With a direct PCI computer connection transaction overhead is minimized for the best overall performance The 82350B card de couples GPIB transfers from PCI bus transfers Buffering provides connectivity and system performance that is superior to direct memory access DMA The hardware is software configurable and compatible with the plug and play standard for easy hard
13. on in the Declaration of Conformity Utilize the LAN to access remote Cables Agilent also offers a variety of cables that provide easy and reliable connections Agilent cables are engineered for exceptional reliability and durability even under the harshest conditions Cable Length 10833D GPIB cable 0 5 meter 10833A GPIB cable 1 meter 10833B GPIB cable 2m Choosing a remote connection If you are 1 Connecting to GPIB or RS 232 based instruments 2 Sharing your instruments with more than one user at atime Then select E5810A E5810A ee Up to 14 max via daisy chain You will obtain the best performance E5810A or E5813 1 Connecting to a mix of instruments 2 Allowing one user to access an instrument at a time to avoid access conflict Then select E5813A E5813A when you do the fewest format conversions For example using the E5810A LAN to GPIB data transfer will generally be faster than 10833C GPIB cable 4m 10833F GPIB cable 6m 10833G GPIB cable 8m Adapters 10834A GPIB to GPIB adapter The 10834A GPIB to GPIB adapter can help when limited rear panel space and other design considerations make cabling difficult The 10834A adapter extends the first cable by 2 3 cm away from the rear panel to provide clearance for other connectors switches and cables 82357B and an E5813A LAN to USB to GPIB 82350B GPIB aa 82351A
14. ook or desktop PC to up to four RS 232 instruments or devices There are no switches to set no PC cards to install and no external power supplies are required Simply install the driver and plug in the E5805A USB 4 port RS 232 interface to add four RS 232 ports to your computer The E5805A is a standard plug and play device Your computer automatically detects and configures it when it is connected to the USB port of the computer You can interface up to four devices with baud rates of up to 230 Kb s per serial port The E5805A provides four DB9 serial connectors and ships with a 1 8 meter USB cable Agilent Technologies E5805A USB 4 port RS232 Interface Turn your USB port into 4 additional RS 232 ports E5805A Technical Specifications General Requirements Minimum system requirements Windows 98 SE Me note 98 runs with version 14 0 only 2000 XP A USB port Software required E5805A driver included Software recommended Agilent connectivity Libraries Suite included see system requirements on page 2 Supported standards USB 1 1 fully compatible with USB 2 0 EIA 232 General Characteristics Power USB bus powered device 5 V 500 mA max 200 mA typ Support for USB hubs Self powered hubs Connectors Standard USB A RS 232 9 pin on each port Cable 1 8 meter USB USB A host side to USB B device side Maximum data rates 230 Kb s per port RS 2
15. technology to overcome the 5 meter distance limitation for USB cabling so you can place USB devices anywhere on a LAN With access to remote devices you can collect data perform measurements or monitor the progress of your tests Using the bundled 10 Libraries Suite you can connect an Agilent 82357B USB GPIB interface to one of the USB ports for access to GPIB devices You can additionally connect an E5805A USB 4 port RS 232 interface for access to RS 232 devices see figure on page 9 To prevent access conflicts only one computer at a time can access the E5813A The included software lets you lock the E5813A to your computer Once you unlock the connection another user can then connect from a different computer To choose between a E5810A or a E5813A for your applications please refer to page 9 Agilent Technologies E5813A Networked 5 port USB hub USB GPIB or RS 232 instruments or devices E5813A Technical Specifications General Requirements Minimum system requirements e Windows 2000 XP Available USB 1 1 or 2 0 port Software required E5813A driver included Software recommended Agilent connectivity Libraries Suite included see system requirements on page 2 Supported standards 10BASE T 100BASE TX networks USB 1 1 fully compatible with USB 2 0 General Characteristics Power supply External switching AC adapter Input power consumption 120 230 volts A
16. ter Related Agilent literature Modern Connectivity Using USB and LAN connectivity Converters Application note 1475 1 pub no 5989 0123EN Simplified PC Connections for GPIB Instruments Application note 1409 1 pub no 5988 5897EN e Using LAN in Test Systems The Basics Application note 1465 9 pub no 5989 1412EN Using LAN in Test Systems Network Configuration Application note 1465 10 pub no 5989 1413EN Using USB in the Test and Measurement Environment Application note 1465 12 pub no 5989 1417EN e Computer connectivity Considerations Application note 1465 2 pub no 5988 9818EN 10 Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2010 ee Printed in USA March 18 2010 Authorized Agilent Distributor 5989 1889EN Click here to Buy TRANSIT MEEN O l EERIE Transcat com ote Agilent Technologies
17. vice USB LAN LAN USB E ag i trigger stam RS 232 p Device Device GPIB a PCI PCle Ordering Information Product Number Product Description 82357B USB GPIB interface includes Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM 82350B High performance PCI GPIB interface includes Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM 82351A High performance PCle GPIB Interface Card includes Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM Additional manual set Option 0B1 Japanese User s Guide Option ABJ E5810A LAN GPIB gateway includes Agilent I0 Libraries Suite and VISA SICL programming manuals on CD ROM Rack mount kit for 1 or 2 E5810A s Option 100 E5818A LXI Class B Trigger Box includes Agilent 10 Libraries Suite and SCPI programming manuals on CD ROM E5805A USB 4 port RS232 interface includes USB cable Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM 5813A Networked 5 port USB hub includes power adapter Agilent 10 Libraries Suite and VISA SICL programming manuals on CD ROM 10833D 0 5 meter GPIB cable 10833A 1 meter GPIB cable 10833B 2 meter GPIB cable 10833C 4 meter GPIB cable 10833F 6 meter GPIB cable 10833G 8 meter GPIB cable 10834A GPIB to GPIB adap
18. ware installation The GPIB interface card plugs into a 5 volt PCI slot in the backplane of your PC Regarding programming capability you have access with the latest version of 10 Libraries suite version 15 0 or higher to program in all standard development environments Agilent s I0 Libraries Suite 15 0 or higher is easy to use and works with virtually any vendor s instrument or T amp M programming software application and includes automatic configuration for Agilent or NI VISA NI 488 2 or VISA COM connectivity Even if you use NI connectivity software Agilent will configure automatically so as a user you do not have to concern about the behind the scenes details i gt Agilent 82350B PCI GPIB This traditional GPIB connection still offers the highest throughput 82350B Technical Specifications General Requirements Minimum system requirements Windows 2000 XP Vista Windows 7 Software required PCI bus slot Agilent 10 Libraries Suite included 450 MHz Pentium II 1 GHz 32 bit recommended for Vista and Windows 7 256 MB RAM 1 GB or greater is recommended for Vista and Windows 7 1 5 GB free disk space 1 GB for Microsoft NET Framework 2 0 and 65 MB for Agilent I0 Libraries Suite is recommended 5 V PCI slot 32 bits Supported standards IEEE 488 1 and IEEE 488 2 compatible General Characteristics Power Backplane 5 V PCI Connectors Standard 24 pin GPIB

Download Pdf Manuals

image

Related Search

Related Contents

Lightolier 1050RNDL_3D User's Manual  マイコンポジショナ マイコンポジショナ(電空式) ME 1100/1200 シリーズ  BEDIENUNGSANLEITUNG MODE D´EMPLOI USER MANUAL  User`s Manual - B&H Photo Video Digital Cameras, Photography  Direction des relations du travail  Istruzioni d`uso Moisture Analyzer HR83 e HR83-P  Harman Kardon GPS-500 User's Manual  Switch RF serie RFS7000    基本 CMYK - アピックスインターナショナル  