EN6080 Users Manual

image

Contents

1. 3 18 15 06443E 2015 Inovonics www inovonics com 12 Home 2 1 1 System Connection Summary The system connection summary fields on the home screen allow the system to be viewed at a glance The Devices Registered field displays the total number of devices registered to the EN6080 area control gateway The Devices In Alarm field displays the number of registered devices that are in alarm The Devices Inactive field displays the number of registered devices that are inactive A device is considered inactive if the EN6080 area control gateway has not received a check in message from the device during the supervision window indicating the radio link has been broken 2 1 2 Device Information The device information table located below the system connection summary displays an overview of each registered device All columns are sortable simply click on any column header to sort in ascending or descending order The search field can be used to locate specific devices it covers data in all fields and accepts letters and numbers but no wildcard characters The following information is included The TX ID field displays the factory coded unique identification number of the transmitter The TX ID is primarily used for registration The Device Status field displays whether the device is active or inactive A device is considered active if a check in message has been received during the p
2. Figure 5 2 Repeater reset warning message 4 Alist of repeaters registered to the system will display in a pop up window Network Coordinator Update The network ID was updated successfully on the EN6080 The following repeaters will display a check mark once the EN6080 starts receiving communication from them 7848859 Repeater Terminal 5 9151017 Repeater 2 Figure 5 3 Registered repeaters 5 Go to the first repeater in your system 3 18 15 06443E 2015 Inovonics www inovonics com 27 Wireless Setup 6 Open the cover and press the reset button 7 Wait ten seconds and replace the cover 8 Make sure a check displays next to the repeater you just reset in the window shown in Figure 5 3 If not reset the repeater again making sure to wait ten seconds before replacing the cover if so reset the next repeater Repeat until all repeaters in the system have been reset 9 Once all repeaters are reset Click Close on the reset checkbox window All repeaters are now registered 10 Navigate to the home screen and ensure all repeaters are shown as active within three to four minutes 3 18 15 06443E 2015 Inovonics www inovonics com 28 Chapter 6 Device Setup The device setup tab is used to register unregister and manage the Inovonics devices and repeaters that make up your system It is only accessible to admin level users There are three ways to register the Inovonics end devices and repeate
3. 3 2 2 Configure a DHCP IP Address By default the EN6080 is configured with a static IP of 192 168 60 80 and a subnet mask of 255 255 255 0 You will also need to ensure that the target network has a DHCP server on it 1 2 3 Select the DHCP radio button Click Update A dialog box will display reading This update will require a reboot of the ACG Once you make this change the browser will automatically update to the new address Are you sure you want to make this change Click OK 3 18 15 06443E 2015 Inovonics www inovonics com 18 ACG Setup The EN6080 area control gateway will request a new IP address from the DHCP server and if successful display the IP update dialog box shown in Figure 3 3 Write down the new IP address displayed in the IP update dialog box IP Update EN6080 DHCP configuration started New pending address is 192 168 2 174 Accepting the IP address will cause the EN6080 to reboot Figure 3 3 IP update dialog box 4 Click Accept New IP 5 The EN6080 area control gateway will reboot When the Refresh button displays click it 3 3 Date and Time Setup The EN6080 area control gateway contains a real time clock that is used to tag events and log entries The date and time setup screen is used to configure the date and time of that clock It is only accessible to admin level users The area control gateway can either poll the Network Time Protocol servers to aut
4. The EN6080 area control gateway trims the extra spaces on the start and end and they are case insensitive TX ID Type and Supervision are required fields All other fields may be empty but must have a comma Following is an example of a correctly formatted csv file e 1050958 EN1249 all team 7200 1009716 EN1223S joes office 7200 1289716 EN1242 hallway 7200 1059246 EN1215W lab area 7200 1664246 EN1240 board room 7200 3 18 15 06443E 2015 Inovonics www inovonics com 35 Device Setup lt INOVONICS ACG Setup Wireless Setup l Device Setup File Management Manual Administration Automatic Administration Upload Administration Devices In Alarm 4 Upload Administration Select a comma separated csv file of devices to register Figure 6 4 Upload administration screen 6 3 1 Upload a Spreadsheet of Devices to Register 1 ST A o Click Browse Navigate to the csv file of devices you wish to register Click Open Click the Load button All devices that parse properly and are unregistered will be selected by default Deselect any devices that you do not want to register Click Register Note You can also unregister devices by highlighting the devices you want to unregister and clicking Unregister 3 18 15 06443E 2015 Inovonics www inovonics com 36 Device Setup If there are lines that cannot be parsed due to formatting erro
5. Microsoft Corporation in the United States and other countries Mozilla and Firefox are registered trademarks of the Mozilla Foundation Celeron Core Pentium and Intel are trademarks of Intel Corporation in the U S and or other countries All brand other names and product names used in this manual are trademarks registered trademarks or trade names of their respective holders 3 18 15 06443E 2015 Inovonics www inovonics com 4 Preface Technical Services Contact Information For Inovonics technical services E mail support inovonics com Phone 800 782 2709 303 939 9336 Document Conventions The following notices are used throughout this document Note Emphasizes points provides supplementary information or indicates minor problems in an expected outcome Caution Indicates possible damage to equipment or loss of data as well as potential problems in an expected outcome Warning Indicates the possibility of minor injury to oneself or others Danger Indicates the possibility of serious or fatal injury to oneself or others 3 18 15 06443E 2015 Inovonics www inovonics com 5 Chapter 1 EN6080 Area Control Gateway Overview 1 1 Introduction The Inovonics EN6080 area control gateway bridges the Inovonics proprietary commercial mesh network to a standard TCP IP over Ethernet LAN allowing the entire range of Inovonics physical security products to be added to any IP based or PSIA revision 0 8
6. any logs you need to save are updated to the host application before updating the firmware For more information about logs see Logs on page 38 Note The EN6080 area control gateway will not stream events while the update is in progress no alarms will be processed while this update is occurring 3 18 15 06443E 2015 Inovonics www inovonics com 45 File Management 8 2 1 Update Firmware Inovonics will send you firmware update files as necessary To update firmware 1 2 3 4 Click the Browse button Navigate to the firmware update file Click the Start Firmware Update button Once the firmware update is complete click the Close button The EN6080 area control gateway will reboot completing the update 3 18 15 06443E 2015 Inovonics www inovonics com 46 Glossary Alarm message The alarm message indicates an end device change of state such as an open close contact alarm Check in message A check in message is a Supervisory message sent between EchoStream devices at set periods of time to ensure the device is functioning properly Device Any component in an EchoStream system including end devices repeaters as well as the EN6080 area control gateway End device Any transmitter or transceiver used by an EchoStream system to send data Mobile duress pendant A pendant transmitter worn on a person allowing them to send an alarm anywhere within the coverage area NID network ID T
7. compliant system using RESTful web services Inovonics security products include motion detectors glassbreak sensors panic buttons and door window sensors All of these operate on the self monitored and fully supervised Inovonics EchoStream commercial mesh network Designed to move small amounts of data over a moderate range in commercial environments the commercial mesh network uses a frequency hopping spread spectrum technology that sends redundant messages across multiple channels to avoid interference obstacles Due to its low latency and high reliability the EchoStream commercial mesh network is an ideal solution for security applications The network is secure and dedicated ensuring personal security messages are delivered without interference from less critical applications The EN6080 area control gateway includes a built in web page server for complete system setup and configuration as well as enhanced on demand system supervision for detailed event audits This manual covers the EN6080 area control gateway s web page server For installation information see the EN6080 Area Control Gateway Installation Instructions for information about integrating the EN6080 area control gateway into a PSIA revision 0 8 system see the EN6080 Area Control Gateway Integration Guide 3 18 15 06443E 2015 Inovonics www inovonics com 6 EN6080 Area Control Gateway Overview 1 2 Recommended System Requirements The computer used
8. on any column header to sort in ascending or descending order The search field can be used to locate specific logs it covers data in all fields and accepts letters and numbers but no wildcard characters Note The alarm logs screen will only refresh when the Retrieve Logs button at the bottom of the screen has been clicked As a matter of course it is a good idea to click Retrieve Logs upon viewing any logs screen INOVONICS b Wireless Setup Alarm Logs SystemLogs File Management Trouble Logs Devices In Alarm 4 Date and Time Description Search Partitions 12 2 2014 17 40 06 744 700 12 2 2014 17 50 33 222 700 12 2 2014 19 22 11 739 700 ALARM 1 CLR 5 ALARM1CLR 6 ALARM 1 2 Ce 12 2 2014 19 51 09 381 700 12 2 2014 19 56 26 535 700 12 2 2014 19 56 09 244 700 12 2 2014 21 52 28 667 12 2 2014 21 52 28 667 700 12 2 2014 21 55 55 695 700 ALARM 1 CLR 12 3 2014 6 55 37 728 700 32 8 2014 6 5637 381 700 12 3 2014 7 00 36 302 700 12 3 2014 8 56 06 645 700 12 3 2014 8 57 02 700 12 3 20148 5702 763 700 12 3 2014 8 57 06 497 700 12 3 2014 8 57 37 860 700 12 3 2014 8 58 06 027 700 12 3 2014 8 58 06 705 700 EN12238S Pendant Soft Pointer EN1223S Pendant Soft Pointer EN1240 Activity EN1240 Activity Long Term Motion 4 15628128 ALARM 1 E ALARM 1 CLR 2 4 12 2 2014 19 13 45 495 700 ALARM 1 CLR 15627591 15628015 EN
9. to 99 Signal margin The difference between the signal level of a message and noise floor of channel Status message A status message is a supervisory message that contains information on the status of the device such as a low battery condition Supervision time The interval of time in which at least one supervision message must be received from a device before the EN6080 area control gateway considers it inactive Supervisory message Either a check in message sent by one device to another to verify a successful link between the devices or a status message sent to report a status change TXID Transmitter identification number A unique identifier assigned to each device at the factory primarily used for registration Transmitter A one way end device that transmits RF messages outward through the repeater network to the EN6080 area control gateway 3 18 15 06443E 2015 Inovonics www inovonics com 48 This page intentionally left blank
10. to access the EN6080 area control gateway should meet the following requirements e Windows 7 operating system or later e Mozilla Firefox version 35 or later Internet Explorer version 11 or later Wired Ethernet interface Minimum MTU 1280 bytes 1 3 EN6080 Area Control Gateway Initial Setup and Connection 1 3 1 Disable Delayed ACK Mode on the Windows 7 Operating System The EN6080 area control gateway currently does not respond to the delayed ACK mode of operation that some Windows 7 machines use Microsoft has provided a fix for this as outlined below A future revision of the EN6080 software will eliminate the need for this fix To disable delayed ACK mode in Windows 7 Service Pack 1 or above 3 18 15 06443E 2015 Inovonics www inovonics com 7 EN6080 Area Control Gateway Overview 1 Open up the registry Programs 1 ay regedit ex Open Run as administrator Scan with AVG Add to archive Add to regedit rar Compress and email Compress to regedit rar and email Pin to Taskbar Pin to Start Menu Restore previous versions Adobe Drive CS4 gt PowerlSO gt Send to gt Cut Copy Delete Open file location MJ Search Every p e roperties regedit exe x Shut down gt Figure 1 1 Open the registry 2 Un collapse the following entry HKEY_LOCAL_MACHINE SYSTEM CurrentControlSet services Tcpip P arameters Interfaces 3 You will pr
11. 0 area control gateway It is only accessible to admin level users INOVONICS ACG Setup Wireless Setup Partitions Device Setup File Management User Administration IP Administration Date and Time Setup Devices In Alarm Q IP Setup DHCP Static IP 192 168 2 160 Subnet 255 255 252 0 Gateway 192 168 1 1 Figure 3 2 EN6080 area control gateway IP setup screen 3 18 15 06443E 2015 Inovonics www inovonics com 17 ACG Setup 3 2 1 Configure a Static IP Address By default the EN6080 is configured with a static IP of 192 168 60 80 and a subnet mask of 255 255 255 0 Before configuring the IP address you will need to attain a known good static IP address subnet mask and gateway on the target network from your IP administrator To configure a static IP address 1 Do ms CES qu Select Static to choose a static IP address for the EN6080 area control gateway Enter the known good IP address in the IP field Enter the subnet mask of the IP network in the Subnet field Enter the gateway for this IP network in the Gateway field Click Update to configure the EN6080 area control gateway IP address A dialog box will display reading This update will require a reboot of the ACG Once you make this change the browser will automatically update to the new address Are you sure you want to make this change Click OK When the Refresh button displays click it
12. 1240 Activity EN1240 Activity Long Term Motion 4 Long Term motion 15628085 15628128 EN1240 Activity EN1240 Activity Long Term Motion 2 Long Term Motion 3 15627591 15628085 EN1240 Activity 15628085 eu 2 T eem EN1240 Activity Long Term Motion 3 Long Term Motion 4 manmi cin Zeen Ent2ao Ati Lang Term maton 5 15628085 EN1240 Activity LongTermMon3 BE EE ele Ee Ee EE 4 15628015 EN1240 Activity LongTermMotion2 EN1240 Activity Long Term motion e Figure 7 1 Alarm logs screen 3 18 15 06443E 2015 Inovonics www inovonics com 39 Logs 7 2 1 Retrieve and Save Logs 1 Click the Retrieve Logs button All available alarm events will display 2 Click Save Logs to open the list of events as a comma separated file in your web browser 3 Asdesired save the comma separated file as a text file to your computer 7 3 System Logs The system logs screen is used to view and save system events All columns are sortable simply click on any column header to sort in ascending or descending order The search field can be used to locate specific logs it covers data in all fields and accepts letters and numbers but no wildcard characters Note The systems logs screen will only refresh when Retrieve Logs has been clicked As a matter of course it is a good idea to click Retrieve Logs upon viewing any logs scr
13. EN6080 Area Control Gateway User Manual GED INOVONICS Table of Contents Preface 4 Chapter 1 EN6080 Area Control Gateway Overview 6 LB Te cO iD ec 6 1 2 Recommended System Requirements eeeeeenneee 7 1 3 EN6080 Area Control Gateway Initial Setup and Connection 7 1 3 1 Disable Delayed ACK Mode on the Windows 7 Operating System 7 1 3 2 Configure Network Settings for Windows 7 esses 9 1 3 3 Browse to the EN6080 Area Control Gateway Web Server Screens 10 1 3 4 License Key Setup E 10 Chapter 2 Home 12 VN PAID M CP t 12 2 1 1 System Connection Summary eeeesseseseeseneeneen entrent 13 2 1 2 Device Information esesseeeseseeseeeeenene nennen nnne entrent nnn nennen nnn 13 2 2 Site Information ET T 14 2 2 1 Le chldrTu Eu ITT 15 2 2 2 Contact Information eese eene 15 Chapter 3 ACG Setup 16 3 T User Administration 5 eret dei tre rae citu Ree Eassa 16 3 1 1 Update User or Admin Password eeeeeeeeeeeeen eene enne nennen 17 3 2 IP Administration o 5 rote eH Ea e eeu Reo naL eoe EK P Eeer 17 3 2 1 Configure a Static IP Address cccesseeeceseneeeee seen eeeeeeeseeeeeeeeeeeeeeeeeeesneeeaes 18 3 2 2 Configure a DHCP IP Address een 18 3 3 Date and Time S
14. SING 5 15628005 En1240 Activity Long TermMotion 3 5 5628085 15628085 EN1240 Activity Long Term Motion 3 Figure 7 3 Trouble logs screen 7 4 1 Retrieve and Save Trouble Logs 1 Click the Retrieve Logs button All available trouble events will display 2 Click Save Logs to open the list of events as a text file which can be saved to your computer 3 18 15 06443E 2015 Inovonics www inovonics com 42 Chapter 8 File Management 8 1 System and Configuration Files When the file management tab is clicked the system and configuration files screen displays The system and configuration files screen is used to back up and restore configuration files It is only accessible to admin level users Included in the configuration file are All end device information e All partition information All site information All user authorization information 3 18 15 06443E 2015 Inovonics www inovonics com 43 File Management CEP INOVONICS Home ACG Setup Wireless Setup Partitions Device Setup Logs File Management System and Configuration Files License Key Firmware Update Devices In Alarm 0 Restore Configuration Please select a configuration file and then click on Restore button to start the configuration restoration process Browse No file selected Backup Configuration Please click on Backup button to start the configuration b
15. a minimum of ten times the device s check in rate 3 18 15 06443E 2015 Inovonics www inovonics com 31 Device Setup 5 Click Register to complete registration of the device 6 1 2 Unregister a Registered Device To unregister a registered device 1 Click the checkbox next to the registered device you wish to unregister 2 Click Unregister 3 Click OK to confirm 6 2 Automatic Administration The automatic administration screen is used to discover Inovonics end devices and repeaters by the push of a reset button Once the EN6080 area control gateway is set into discovery mode a push of a transmitter s reset button will automatically populate the transmitter s identification number and product type All columns are sortable simply click on any column header to sort in ascending or descending order The search field can be used to locate specific devices it covers data in all fields and accepts letters and numbers but no wildcard characters lt E InovoniCS Home ACG Setup Wireless Setup Partitions Device Setup Logs File Management Manual Administration Automatic Administration Upload Administration Devices In Alarm Q Automatic Administration Discovered Devices f Supervision s Registered See Registered Devices Search Type Description Supervision s EN12238S Pendant Load Element 495 3400 a 495 D Le 5 EN1223S Pendant Load Element 496 EN1223S Pe
16. ackup process Figure 8 1 System and Configuration Files screen 8 1 1 Back Up Configuration Files To backup configuration files 1 Click the Backup button 2 Follow the prompts from your web browser to save the file 8 1 2 Restore Configuration Files To restore configuration files 1 Click the Browse button Navigate to the configuration backup file Click the Open button Click Restore Once configuration is restored click Close The EN6080 area control gateway will reboot completing configuration ST qe ge qe 3 18 15 06443E 2015 Inovonics www inovonics com 44 File Management 8 2 Firmware Update The firmware update screen is used to update the EN6080 area control gateway firmware to the latest version It is only accessible to admin level users INOVONICS ACG Setup Wireless Setup Partitions Device Setup File Management y Firmware Update System and Configuration Files License Key Devices In Alarm 1 Warning The system will restart after the update has been applied to complete the process It takes approximately 3 5 minutes gt to reboot To start Firmware update Click Browse or Choose File to locate the file Click Start Firmware Update to begin update ETT Start Firmware Update 0 62 69 Figure 8 2 Firmware update screen Note All of the EN6080 area control gateway s logs will be reset during the firmware process Ensure that
17. cs www inovonics com 14 Home 2 2 1 ACG Information Displays information about the EN6080 area control gateway The EN6080 Serial Number field displays the factory coded unique serial number of the EN6080 area control gateway The Manufacture Date field displays the manufacture date of the EN6080 area control gateway The Firmware Version field displays the version of the firmware loaded in the EN6080 area control gateway 2 2 2 Contact Information Though optional contact information should be provided to allow a remote administrator to contact the local technician in the event of maintenance or updates To fill out contact information 1 Enter the name of the facility in which the EN6080 area control gateway is being used in the Facility Name field Up to 30 characters can be entered Enter the first name of the contact for the facility in the First Name field Up to 100 characters can be entered Enter the last name of the contact for the facility in the Last Name field Up to 100 characters can be entered Enter the phone number for the contact for this facility in the Phone 1 field The two phone number formates accepted are XXX XXX XXXX and XXXXXXXXXX Optionally enter a second phone number for in the Phone 2 field The two phone number formates accepted are XXX XXX XXXX and XXXXXXXXXX Click Update to submit the site information to the EN6080 area control gateway for
18. e removed from a partition before it can be deleted To delete a partition 1 Click the partition you wish to delete 2 Click Delete 3 Click OK to confirm deletion 3 18 15 06443E 2015 Inovonics www inovonics com 25 Chapter 5 Wireless Setup 5 1 Wireless Setup The wireless setup tab is used to set up the network id NID of the EchoStream network The NID is used by the network of high power repeaters and two way end devices to keep messages in separate EchoStream networks from overlapping It is only accessible to admin level users T sS EXE Wireless Setup Partitions File Management Devices In Alarm Q Network Coordinator Administration Network ID NID 14 pain Figure 5 1 Wireless setup screen 3 18 15 06443E 2015 Inovonics www inovonics com 26 Wireless Setup 5 1 1 Update the NID To update the NID 1 Select a NID from the Network ID NID dropdown menu Make sure the NID you select is different from that of any other EchoStream systems that might interfere with yours Caution The NID setting of 0 is only used for diagnostics purposes Make sure the NID you pick is greater than 0 2 Click Update to change to the new NID 3 The following displays Click Update to continue Are you sure you want to change the Update Network ID This will require resetting all repeaters associated Cancel with this NID PEN
19. een 3 18 15 06443E 2015 Inovonics www inovonics com 40 Logs INOVONICS File Management Trouble Logs Devices In Alarm 4 iao13 101603 Power on aaen DHCPNTALENG 325946 EN6080 Receiver DELETED L n wceboww leg EetebRecewer oen EE EE UNEXPECTED SYSTEM RESETSEELOG 3237946 EN6080 Receiver DELETED PS L Namw3i amp 1741 700 PconPis CHANGE 3257946 EN6080 Receiver mm 1 some MM GN NEM assem e Figure 7 2 System logs screen 7 3 1 Retrieve and Save System Logs 1 Click the Retrieve Logs button All available system events will display 2 Click Save Logs to open the list of events as a text file which can be saved to your computer 7 4 Trouble Logs The trouble logs screen is used to view and save trouble events All columns are sortable simply click on any column header to sort in ascending or descending order The search field can be used to locate specific logs it covers data in all fields and accepts letters and numbers but no wildcard characters 3 18 15 06443E 2015 Inovonics www inovonics com 41 Logs Note The trouble logs screen will only refresh when Retrieve Logs has been clicked As a matter of course it is a good idea to click Retrieve Logs upon viewing any logs screen eL INOVONICS j AlamLogs SystemLogs Trouble Logs Devices In Alarm 4 Sea
20. etup EE 19 3 3 1 Poll NTP Servers for Time and Date eene 20 3 18 15 06443E 2015 Inovonics www inovonics com Table of Contents 3 3 2 Synchronize Time and Date with your PC eese 21 Chapter 4 Partitions 22 4 1 Partitions aiiai EE EEeNEE NSA aa aaea a anaana oaiae an 22 4 2 Define a New Partition 2 cccceceeeeeeeee eee eeee eee eee eees eee eneeeeeeeeeeeeeeeseeseeeeneaneeeees 24 4 3 Assign Devices to a Partition eeeseeeeeeeennnneenenn nennen 24 4 4 Remove Devices from a Partition c cceseeeeeeceeeeeeeeeeeeeeeeeeeeeseaneeeeeseeeeees 24 4 5 Update a Partition ceret cee c eene 25 4 6 Delete a Partition teen te eet 25 Chapter 5 Wireless Setup 26 5 1 Wireless Sett p 2 odere neret SEENEN 26 5 1 1 Update the NID 1 23 inue deele Eed 27 Chapter 6 Device Setup 29 6 1 Manual Administration ee EENEG 30 6 1 1 Manually Register a Device sek 31 6 1 2 Unregister a Registered Device ees 32 6 2 Automatic Administration eese nennen 32 6 2 1 Start DISCOVENY reiecit EENS eco ansa coca agn eU eu EENE 33 6 2 2 Edit and Register the Devices c sccccceeeeeeceeeeeeeeeeeeeesseaneeeeeseneeeeeeneeeeeeees 33 6 2 3 Unregister a Registered Device ees 34 6 3 Upload Administration cccccccceceeeeeeeeeeeeeeeeeceeeeeeeeeeeeeeeesseaneeeseeeeeeeeeeeeeee
21. he NID is used by the network of high power repeaters and two way end devices for avoiding messages sent from overlapping EchoStream networks The NID of the network coordinator is assigned a random value between 1 and 31 at the factory The NID of one way end devices is always zero and the NID of high power repeaters and two way end devices default to a value of zero from the factory but may be set to that of the network coordinator at time of registration in the system Your application controller may also change the NID in the event that there is a nearby EchoStream network with the same NID Noise floor The running average of signal strength for each channel that is measured when a valid signal is not present on the channel Partition Partitions are a security term used to group devices together so they can be acted upon as one entity In the context of the EN6080 area control gateway partitions are assigned to devices and typically describe the physical location of the device They are reported with the device s alarm Point A point is the programmable setting to which an end device is registered in the EchoStream system RF Radio frequency Repeater A line powered device that intelligently amplifies transmission from any EchoStream series transmitter while ignoring background noise 3 18 15 06443E 2015 Inovonics www inovonics com 47 Glossary Signal level Signal strength of a message as measured in decibels ranging from 0
22. ity to the lobby assigned to it so they can be managed together The EN6080 area control gateway can manage up to 500 individual partitions It is only accessible to admin level users All columns in the registered devices and partitions fields are sortable simply click on any column header to sort in ascending or descending order The search fields can be used to locate specific devices or partitions they cover data in all fields and accept letters and numbers but no wildcard characters 3 18 15 06443E 2015 Inovonics www inovonics com 22 Partitions lt gt INOVONICS sda ka Figure 4 1 Partitions screen Once a partition is defined the assigned number will display on the home page in the partitions field Placing the cursor over any number in the partitions column will display the name of the partition as shown in Figure 4 2 Partitions L oman 1 Figure 4 2 Partition name 3 18 15 06443E 2015 Inovonics www inovonics com 23 Partitions 4 2 Define a New Partition To define a new partition 1 Click Define New 2 Enter a descriptive name for the partition in the pop up text field The name can be up to 63 characters 3 Click Create The first partition will be created starting with an ID of 1 Additional partitions will be created with sequentially increasing IDs 4 3 Assign Devices to a Par
23. ndant Load Element 497 E EN1223S Pendant Load Element 498 502 EN12238 Pendant Load Element 499 EE EN12238 Pendant Load Element 500 Figure 6 3 Automatic administration screen 3 18 15 06443E 2015 Inovonics www inovonics com 32 Device Setup 6 2 1 Start Discovery To discover devices by automatic administration 1 Click Start Discovery to start discovery mode During discovery mode all unregistered end devices from which a reset message is heard will populate in the discovered devices field Press the reset button on all devices which you wish to register Note For specific information about the location of device s reset button refer to the installation instructions for the device you are registering All installation instructions are available at www inovonics com 3 When you have discovered all the devices to be registered click the Stop Discovery button 6 2 2 Edit and Register the Devices Once devices are discovered they must be registered to include a description and supervision window 4 All ofthe devices discovered in the last session will be highlighted in green indicating they are ready to be registered If you do not wish to register a device at this point click anywhere in the device s field to deselect it Click the Edit button Enter a text description 32 character or less of the end device in the Description field Typically thi
24. nistration screen is used to register Inovonics end devices and repeaters by uploading a spreadsheet with the transmitter information already entered The file needs to be a comma delimited text file and each device to be registered needs to be a separate line in the following format TX ID Type Description Supervision Window Reserved1 Reserved2 Reserved3 e TX ID is the unique serial number for each Inovonics end device The serial number can usually be found on the printed circuit board of the end device 3 18 15 06443E 2015 Inovonics www inovonics com 34 Device Setup Type represents the Inovonics model number of the end device including EN1210 EN1210 240 EN1210 60 EN1210EOL EN1210W EN1210W 60 EN1212 EN1212 60 EN1215 EN1215EOL EN1215W EN1215WEOL EN1216 EN1223D EN1223D 15 EN1223S EN1223S 15 EN1223S 60 EN1224 EN1224 ON EN1233D EN1233S EN1235D EN1235DF EN1235S EN1235SF EN1235SF 15 EN1236D EN1238D EN1240 EN1241 60 EN1242 EN1247 EN1249 EN1252 EN1260 EN1261HT EN1262 EN1265 EN1941 EN1941 60 Description is a 32 or less character string describing the device Typically this is a brief indication of where the end device is used or in the case of a mobile device such as a panic button the name of the person to whom it is assigned e Supervision is a decimal number between 1 and 999999999 up to nine digits representing the seconds to wait until a device is declared inactive
25. nter the transmitter number of the Inovonics device to be registered in the TX ID field The TX ID label is usually found on the printed circuit board of the device or in the case of some devices such as panic buttons on the external housing TX ID label Figure 6 2 TX ID label on a printed circuit board Note The TX ID consists of the initial two smaller digits and the following six larger digits Enter all digits In the example shown in Figure 6 2 for instance you would enter 07155450 2 Enter a 31 character or less text description of the device in the Description field Typically this is a brief indication of where the device is used or in the case of a mobile device the name of the person to whom it is assigned 3 Choose the Inovonics part number of the device from the Type drop down menu Note If the exact product match is not available choose the closest part number E g EN5040 may be selected for EN5040 20T 4 In the Supervision Window field enter a supervision window for the device in seconds Note The supervision window is the period of time during which the EN6080 must hear a check in message from the device or consider it inactive For instance if a device is set with a supervision window of 540 seconds and 540 seconds elapses without the EN6080 hearing a check in message then the device will be considered inactive A good rule of thumb is to set the supervision window at
26. obably find several subfolders Click through each folder until you find the one with the most entries in the right pane The correct interface will have many entries For example DGCPDefaultGateway DHCPDomain DHCPIPAddress Lease NameServer T1 etc A B Tcpip tp Enum Jj Linkage 4 1 Parameters 1 Adapters DNSRegisteredAdapters a d Interfaces 4s 84666342 7039 11de 9d20 806 d 8B175340 8986 4A4B 922C B32 Figure 1 2 Find the subfolder with the most entries 3 18 15 06443E 2015 Inovonics www inovonics com 8 EN6080 Area Control Gateway Overview 4 For each of those entries in the Interfaces folder create two DWORD registry keys called TCPAckFrequency and TCPNoDelay New gt Key 0x00000001 H String Value 0x4b999303 126835 Binary Value Ox4b9e84a3 126867 000000000 0 Figure 1 3 Create DWORD registry keys DWORD 32 bit Value Here s an example what it should look like e TcpAckFrequency 73 TCPNoDelay Figure 1 4 Edited entry example 5 Double click on each new registry key and change the value from 0 to 1 Base hexadecimal 6 Exit the registry editor 7 Reboot your PC 1 3 2 Configure Network Settings for Windows 7 The EN6080 area control gateway comes from the factory configured with a static IP address of 192 168 60 80 To initially communicate with the EN6080 area control gateway you will need to connect to a computer s Ethernet port This might mean disconnecting from y
27. omatically synchronize the time and date or synchronize time and date with the computer connected to the EN6080 If the time reported by the EN6080 area control gateway differs from the time setting on the computer by more than five seconds it will be reported on the home page Discrepancies as small as one second will be reported on the date and time setup page 3 18 15 06443E 2015 Inovonics www inovonics com 19 ACG Setup INOVONICS ACG Setup Wireless Setup Partitions Device Setup File Management User Administration P Administration Date and Time Setup Devices In Alarm Q Date and Time Setup 9 Use NTP IP 174 36 71 205 Sync with PC Monday March 4 2013 11 09 51 AM Figure 3 4 EN6080 area control date and time setup screen 3 3 1 Poll NTP Servers for Time and Date This requires that the EN6080 area control gateway be on a network that allows access to NTP servers To automatically synchronize time and date with Network Time Protocol servers 1 Click Use NTP IP 2 Adefault NTP server address displays If you do not want to use the default IP address enter any known NTP server IP address 3 Click Update 4 When the Date and Time configuration updated dialog box displays click OK If the new time setting differs from the time on your computer by more than one second it will be noted on the date and time setup page 3 18 15 06443E 2015 Inovonics
28. our LAN To connect to the EN6080 area control gateway you will first need to configure the network settings on your computer Note This procedure will change your network settings Make a note of your current network configuration so you can return to it when finished interfacing with the EN6080 area control gateway From the control panel click Network and Internet Click Network and Sharing Center Click Change adapter settings Pow E mg Right click on the local area connection used to connect to the network and select Properties 3 18 15 06443E 2015 Inovonics www inovonics com 9 EN6080 Area Control Gateway Overview Double click Internet Protocol Version 4 TCP IPv4 Select the Use the following IP address radio button Set the IP address to 192 168 60 1 Set the subnet mask to 255 255 255 0 Click OK O m ooo o 1 3 3 Browse to the EN6080 Area Control Gateway Web Server Screens 10 Open the Mozilla Firefox or Internet Explorer web browser and enter http 192 168 60 80 in the address field 11 When prompted enter the admin username and password 12 Click the OK button Note For more information about placing the EN6080 area control gateway on your local network see 3 2 IP Administration on page 17 1 3 4 License Key Setup You should have received a license key to enable your EN6080 area control gateway from the Inovonics customer service depar
29. rch Description Partitions 15627591 EN1240 Activity Long Term motion 15627591 EN1240 Activity Long Term motion 15628085 EN1240 Activity Long Term Motion 3 15628085 EN1240 Activity Long Term Motion 3 15627591 EN1240 Activity Long Term motion 15627591 EN1240 Activity Long Term motion 15628128 EN1240 Activity Long Term Motion 4 5628128 EN1240 Activity 15 Date and Time Event 12 3 2014 3 54 44 073 700 DEVICE MISSING DEVICE MISSING CLR DEVICE MISSING DEVICE MISSING CLR DEVICE MISSING DEVICE MISSING CLR DEVICE MISSING DEVICE MISSING CLR Long Term Motion 4 12 6 2014 14 29 20 315 700 DEVICE MISSING 4 15628015 EN1240 Activity LongTermMotion2 5 afofln njajafjn n T 715628015 ENi240Adiwiy LongTemMolon2 taT2014142541478 700 DEVICE MISSING 2 15627501 ENI24DAdiiy Long Termmotion v22014142712861 00 DEVICE MISSING CLR 2 19627591 ENIZADAGMy Long Temmoton ta72014160533542 700 DEVICE MISSING 4 15628015 ENI240Adiiy Long TermMotion2 32 2014 160653582 700 DEVICE MISSING CLR 4 19628015 ENIZADAGMy LongTemWolon2 27772014 22 32 10 686 700 DEVICE MISSING CLR 6 19628128 EN 240 Actvtly LongTemWolon4 12 20142 13395 700 DEVICEMSSNGCIR 4 19628015 ENIZADAGMy LongTemWolon2 T282014215751357 700 DEVICEMSSNGCIR 6 19628128 ENIZADAGMy LongTemWolon4 12 2014 2249 02783 700 DEVICE MIS
30. rogrammed supervision period indicating the radio link is sound The Alarm State field displays whether or not the device is in a state of alarm The Type field displays the Inovonics model number and device type The Description field displays the user defined description of the device Typically this is a brief indication of where the end device is used or in the case of a mobile device the name of the person to whom it is assigned The Partition field displays the user defined area to which devices are assigned as a single entity For instance front door or lobby Placing 3 18 15 06443E 2015 Inovonics www inovonics com 13 Home the cursor over any number in the partitions column will display the name of the partition as shown in Figure 2 2 Partitions 1 front door 1 Figure 2 2 Partition name 2 2 Site Information The site information screen is used to view EN6080 area control gateway information and edit site information It is only accessible to admin level users lt INOVONICS Wireless Setup Home Site Information Devices In Alarm Q EN6080 Serial Number 90920751 Manufacture Date 02 20 2013 Firmware Version 0 62 69 Contact Information Facility Name Engineering Lab First Name Last Name Phone 1 Phone 2 Figure 2 3 The EN6080 area control gateway site information screen 3 18 15 06443E 2015 Inovoni
31. rs a red warning with the number of unparsed lines will display in the bottom left portion of the screen as shown in Figure 6 5 Hold the cursor over the warning message for details D ia Lines not parsed 1 3002 3003 Lines should only contain seven fields Figure 6 5 Formatting errors message 3 18 15 06443E 2015 Inovonics www inovonics com 37 Chapter 7 Logs 7 1 Logs The EN6080 area control gateway stores logs of all events that impact the system Each log displays the entries in chronological order from oldest to newest Logs are stored in a circular buffer that overwrites the oldest entry when the log is full The logs tab is only accessible to admin level users The EN6080 area control gateway logs events into three categories alarm system and trouble Up to 3000 events can be stored The alarm log includes alarm and alarm clear events for Inovonics end devices The system log includes IP address changes reboot requests shutdowns and other system events The trouble log includes non alarm events for Inovonics end devices including repeater tampers repeaters resets and time adjustments 3 18 15 06443E 2015 Inovonics www inovonics com 38 Logs 7 2 Alarm Logs When the logs tab is clicked the alarm logs screen displays The alarm logs screen is used to view and save alarm events as well as to access the system logs and trouble logs screens All columns are sortable simply click
32. rs that make up your security system e Manually by inputting device information Automatically with a reset button push By uploading a csv file with all registration information already inputted Up to 3000 Inovonics end devices and 500 repeaters can be added to a single EN6080 area control gateway depending on the type of license purchased 3 18 15 06443E 2015 Inovonics www inovonics com 29 Device Setup 6 1 Manual Administration The manual administration screen is used to register unregister and manage devices and repeaters by directly inputting transmitter information All columns are sortable simply click on any column header to sort in ascending or descending order The search field can be used to locate specific devices it covers data in all fields and accepts letters and numbers but no wildcard characters INOVONICS Manual Administration Automatic Administration Upload Administration Devices In Alarm 0 Manual Administration Register a Device Description Supervision Window s P Endpoints 14 registered of 25 allowed TXID Search Supervision s 3600 7200 1059246 7200 7200 1009716 En12238 1050958 En1249 1059937 7200 Figure 6 1 Manual administration screen 3 18 15 06443E 2015 Inovonics www inovonics com 30 Device Setup 6 1 1 Manually Register a Device 1 E
33. s 34 6 3 1 Upload a Spreadsheet of Devices to Register seseuueusss 36 Chapter 7 Logs 38 n We CEET 38 T2 AER IR 39 7 2 1 Retrieve and Save Logs iue NEEN REENEN tnnt nnne 40 Ta ERR D 40 7 3 1 Retrieve and Save System Logs eese 41 TA Trouble Eogs ugein a R E Re E ein eee Ee ERE ER 41 7 4 1 Retrieve and Save Trouble Logs ee 42 3 18 15 06443E 2015 Inovonics www inovonics com 2 Table of Contents Chapter 8 File Management 43 8 1 System and Configuration Files ccccccsssseeeeeeeeeeeeeeeeeeeeneeeeeeeseneeeeeeneseeees 43 8 1 1 Back Up Configuration Files REENEN EEN 44 8 1 2 Restore Configuration Files ek 44 8 2 Firmware Update i si iniaa a Hr e ERERE Ere Taiapa Aina 45 8 2 1 Update Firmware gau Ee EDI dE EES 46 Glossary 47 3 18 15 06443E 2015 Inovonics www inovonics com 3 Preface Notice 2015 Inovonics Inovonics intends this manual for use by Inovonics customers only All comments concerning the contents of this manual should be directed to the Inovonics marketing department No part of this work covered by copyright may be reproduced in any form either graphically electronically or mechanically including photocopying recording taping or storing in an information retrieval system without prior written permission from Inovonics Document Part Number 06443E Trademarks Windows is a registered trademark of
34. s is a brief indication of where the end device is used or in the case of a mobile device such as a panic button the name of the person to whom it is assigned In the Supervision Window field enter a supervision window for the end device in seconds 3 18 15 06443E 2015 Inovonics www inovonics com 33 Device Setup Note Note The supervision window is the period of time during which the EN6080 must hear a check in message from the end device or consider it inactive For instance if a device is set with a supervision window of 540 seconds and 540 seconds elapses without the EN6080 hearing a check in message then the device will be considered inactive A good rule of thumb is to set the supervision window at a minimum of ten times the device s check in rate Most Inovonics security products have a check in time of three minutes or 180 seconds When you enter the supervision time for the first listed device it will automatically populate the supervision field for all other listed devices If this is desirable no further input for supervision time is needed If not you can overwrite devices with different supervision times 8 When you have edited all devices click Register 6 2 3 Unregister a Registered Device To unregister a registered device 1 Click the checkbox next to the registered device you wish to unregister 2 Click Unregister 3 Click OK to confirm 6 3 Upload Administration The upload admi
35. storage 3 18 15 06443E 2015 Inovonics www inovonics com 15 Chapter 3 ACG Setup 3 1 User Administration When the ACG setup tab is clicked the user administration screen displays The user administration screen is used to edit user and admin passwords and provides access to the IP administration and date and time setup screens It is only accessible to admin level users lt gt InoVOnICS ACG Setup Wireless Setup User Administration P Administration Date and Time Setup File Management Devices In Alarm Administrator Account Username Admin Password Reenter Password User Account Username User Password Reenter Password Figure 3 1 EN6080 area control gateway user administration screen 3 18 15 06443E 2015 Inovonics www inovonics com 16 ACG Setup 3 1 1 Update User or Admin Password To change the user or admin password 1 Enter the new password in the Password field under Username Admin or Username User Passwords must be 15 characters or less and can include alpha numeric characters only 2 Reenter the new password in the Reenter Password field 3 Click Update to change the password Note An admin password change will take effect immediately and you will be asked to re enter it to leave the page 3 2 IP Administration The IP administration screen is used to configure the IP address of the EN608
36. tition The create and assign partition field displays all devices in the system and allows them to be added and removed from partitions Each device can be assigned to up to four partitions so they can be managed separately For instance a door contact transmitter mounted on the door to a pharmacy ina supermarket might be assigned to both a pharmacy and a building partition That way one could manage the pharmacy separately from the rest of the building or manage the entire building as a whole To assign devices to a partition 1 Click the checkbox next to all devices you wish to assign to the partition 2 Select the partition to which you wish to assign the devices 3 Click the Assign to Partition button 4 4 Remove Devices from a Partition To remove devices from a partition 1 Click the checkbox next to all devices you wish to remove from a partition 2 Selectthe partition from which you wish to remove the end devices 3 Click the Remove from Partition button 3 18 15 06443E 2015 Inovonics www inovonics com 24 Partitions 4 5 Update a Partition The name of an assigned partition may be edited To edit an existing partition 1 Click the partition you wish to update 2 Click Edit 3 Edit the name of partition in the pop up text field 4 Click Update Once edited the ID number assigned when the partition was created will remain the same 4 6 Delete a Partition All devices must b
37. tment To enter the license key 1 Click the File Management tab 2 Click License Key to display the license key page 3 18 15 06443E 2015 Inovonics www inovonics com 10 EN6080 Area Control Gateway Overview ELA InovoniCS File Management LicenseKey Firmware Update System and Configuration Files No EN6080 license Only 5 endpoints available Devices In Alarm 0 License Key 0 of 5 endpoints available without a license have been registered Enter License Key Figure 1 5 The license key screen 3 Enter the license key received from Inovonics in the Enter License Key field 4 Click the Update button 5 Oncethe License Update message has displayed and the EN6080 area control gateway has rebooted click the Refresh button 6 Your EN6080 is now enabled to support the number of end devices allowed within the purchased tier 3 18 15 06443E 2015 Inovonics www inovonics com 11 Chapter 2 Home 2 1 Home The home screen displays a overview of system information and allows access to the site information screen INOVONICS Home Site Information Devices In Alarm Type a EN ee D En1223S Load Element 499 n1223S Load Element 497 En1223S8 Load Element 496 eem reen FEH En1223S Load Element 493 En1223S Load Element 492 oad Element 49 Figure 2 1 EN6080 area control gateway home screen
38. www inovonics com 20 ACG Setup If the IP address for the NTP server is invalid or the area control gateway is unable to connect a message will display reading NTP Time Server is unreachable and the area control gateway will continue trying again to retrieve the time once a minute until it is successful 3 3 2 Synchronize Time and Date with your PC To synchronize time and date with your computer 1 2 3 4 Ensure the time and date is correct on your host computer Click the Sync with PC button Click Update to update time and date When the Date and Time configuration updated dialog box displays click OK Note If the new time and date is earlier than what is currently set on the EN6080 area control gateway every event that happens after you set the new time will have a time stamp of 1 millisecond greater than the last entry before the time change This will continue until the current time is greater than what the modified event time would be At that point events will display the proper time stamp This prevents log irregularities 3 18 15 06443E 2015 Inovonics www inovonics com 21 Chapter 4 Partitions 4 1 Partitions The partitions tab is used to add delete and manage partitions Partitions are user defined controllable areas to which devices are assigned and managed as a single entity For instance lobby might be a partition with all the devices that provide secur

Download Pdf Manuals

image

Related Search

Related Contents

映像分配器 KBW-48A (4 入力 8 出力) 取扱説明書  IAN 113230 - Lidl Service Website  1. Visualiser la « carte » de mon réseau social  F55_F5_V3_operation_Manual  Ingenico 6500 Credit Card Machine User Manual  SCAMBIATORI DI CALORE A PACCO ALETTATO  Manual de instalação  Lichtsteuereinheit mit Empfänger  Samsung Profile User Guide  