Home

QSP-100 operator`s manual

image

Contents

1. Each 16C550 UART contains 8 I O registers The last of these registers located at Base address 7 is referred to as the Scratchpad Register and provides no functionality to the UART In place of this Scratchpad Register the QSP 100 implements an interrupt status register which can be accessed at Base address 7 of any UART The purpose of the interrupt status register is to give the software programmer an easy way to inspect the interrupt state of the entire QSP 100 with a single input operation The format of the interrupt status register is shown below D7 D6 D5 D4 D3 D2 D1 DO 0 0 0 0 Intr D Intr C Intr B Intr A When one or more UARTs have interrupts pending the associated bit s in the interrupt status register are set to logic 1 When all the pending interrupts have been serviced for a specific UART its interrupt status bit will be cleared to logic 0 automatically When all the pending interrupts from all UARTs have been serviced the entire interrupt status register will return logic 0 The application program should not exit its interrupt service routine until all pending interrupts from all channels have been serviced interrupt status register 0 or no additional interrupts will be received If an application requires the UARTs Scratchpad Registers the interrupt status register can be disabled using the p option on the QSP 100 Client Driver for DOS or the DOS Enabler command li
2. DOS memory when configuring a QSP 100 This region is 1000H bytes 4KB long and by default begins at address DOOOOH the default address may be changed using the W option If a memory manager such as EMM386 QEMM or 386Max is installed on the system this region of DOS memory must be excluded from the memory manager s control Consult the documentation provided with the memory manager software for instructions on how to exclude this memory region QSP 100 User s Manual 2 2 1 Command Line Options To configure a QSP 100 in the system the Enabler requires one command line argument from the user to determine the configuration of the card This argument must be enclosed in parenthesis and within the argument any or all of the following parameters may be specified using a comma no spaces to separate each parameter Ssocket Baddress lirg Waddress specifies which PCMCIA socket the QSP 100 must be inserted into for this configuration argument to be used socket must be in the range 0 15 This option is always required specifies the base I O address of the QSP 100 in hexadecimal and must reside on an even 32 byte 20H boundary This option is required if the R option is not used specifies the interrupt level IRQ of the QSP 100 in decimal irq must be one of the following values 3 4 5 7 9 10 11 12 14 15 or 0 if no IRQ is desired This option is required if the R option is not used spe
3. QSP 100 Settings 3 The New Hardware Found window provides several options to configure the QSP 100 card Click the Driver from Disk option button Click OK to continue 4 An Install from Disk dialog box shoud appear Insert the diskette with the QSP 100 INF file the MLTPT_SP INF and the SERIALOT VXD file into the disk drive select the correct drive letter and path and click OK Windows 95 will browse the path for the aforementioned files 5 During the installation process it may be required to supply the computer with the Windows 95 CD or installation diskettes The QSP 100 s child devices will require the file SERIALUI DLL Insert the CD or diskette and click OK a IMPORTANT NOTE If the user already has these files installed on the computer or if the installation disks are unavailable it may not be necessary to supply the computer with the Windows 95 CD or installation diskettes If prompted for the disks click OK A dialog box with an option to skip will appear Click the Skip button and the files will not be installed If the latest version of these files exist in the system directory those files will be used 6 The QSP 100 PC Card should now be configured In the future Windows 95 will automatically recognize and configure the QSP 100 QSP 100 User s Manual 21 4 2 Viewing the QSP 100 Resource Settings The following steps detail how to view the resource settings that Windows
4. interrupt status register will be disabled Scratchpad registers enabled and the BIOS equipment list will be updated 2 1 2 5 Example 5 DEVICE C QSP 100 QSP100CL SYS b300 i5 i10 In example 5 three command line arguments are provided The Client Driver will first attempt to configure a QSP 100 inserted into any socket with a base address of 300H and IRQ 5 If address 300H or IRQ 5 is unavailable the Client Driver will proceed to the second command line argument and attempt to configure the card with a base address assigned by Card and Socket Services and IRQ 10 If IRQ 10 is also unavailable the Client Driver will proceed to the third command line argument and attempt to configure the QSP 100 with a base address and an IRQ assigned by Card and Socket Services If the QSP 100 is successfully configured its interrupt status register will be enabled and the BIOS equipment list will not be updated 2 1 2 6 Example 6 DEVICE C QSP 100 QSP100CL SYS b300 i5 i10 In example 6 the three command line arguments of example 5 have been re arranged The Client Driver will first attempt to configure a QSP 100 inserted into any socket with a base address of 300H and IRQ 5 If address 300H or IRQ 5 is unavailable the Client Driver will proceed to the second command line argument and attempt to configure the card with a base address and IRQ assigned by Card and Socket Services Since the second command line argument includes all av
5. 00 The base address and IRQ parameters are ignored and may be omitted 2 2 1 6 Example 6 QSP100EN EXE s1 r wcc In example 5 the Enabler will release the configuration used by the QSP 100 in socket 1 using a configuration memory window at segment CCO00 12 2 2 2 Common Problems Memory Range Exclusion The Enabler requires a region of high DOS memory when configuring a QSP 100 This region is 1000H bytes 4KB long and by default begins at address DOO00H the default address may be changed using the W option If a memory manager such as EMM386 QEMM or 386Max is installed on the system this region of DOS memory must be excluded from the memory manager s control Consult the documentation provided with the memory manager software for instructions on how to exclude this memory region Furthermore some systems use the high memory area for BIOS shadowing to improve overall system performance In order for the Enabler to operate any BIOS shadowing must be disabled in the address range specified for the configuration window BIOS shadowing can usually be disabled through the system s CMOS setup utility Socket Numbers The Enabler requires the QSP 100 s socket number to be specified on the command line and the QSP 100 must be inserted into the socket before the Enabler is invoked Some vendors number their sockets from 1 to N while other vendors number their sockets from 0 to N 1 For the QSP 100 Enabler the lowest socket
6. 1 Introduction The QSP 100 provides four independent RS 232 asynchronous serial communications interfaces for systems equipped with PCMCIA Type II and or Type II expansion sockets The QSP 100 is a PCMCIA Type II 5 mm card and is PCMCIA PC Card Standard Specification 2 1 compliant The QSP 100 s serial ports are implemented using 16C550 Universal Asynchronous Receiver Transmitters UARTs which are the recommended communications interface for multitasking environments and with applications involving high data transfer rates The QSP 100 s four serial ports are addressed in a single 32 byte I O block for simplified programming and all four channels share a common interrupt IRQ A special interrupt status register is also available to simplify the software required to service multiple serial ports in an interrupt driven environments QSP 100 User s Manual 1 2 DOS Windows 3 x Installation Two configuration software programs are provided with the QSP 100 a Client Driver QSP100CL SYS and a card Enabler QSP100EN EXE Both of these programs are executed from DOS before entering Windows and allow operation of the QSP 100 in both the DOS and Windows 3 x environments For optimal operation however the Client Driver is the preferred method of installation and configuration The table below highlights the differences between these programs Client Driver recommended Enabler not recommended File name QS
7. 95 has allocated for the QSP 100 Double click on the My Computer icon located on the Windows 95 desktop This opens a folder showing various drives Control Panel etc Double click on the Control Panel icon This opens another folder with many different system utilities Double click on the System icon This opens the System Properties window Click on the Device Manager tab Double click on the item Ports Com amp LPT located within the list of hardware Double click on any of the items labeled Omega Multi port COM x where x represents the logical COM port number The items labeled Omega Multi port are the child devices of the QSP 100 parent device Click the Resources tab at the top of the System Properties box The base I O address and IRQ level displayed here is the base I O address and IRQ level of the entire parent device The resources cannot be modified here For information on how to change these settings got to the section labeled Changing Configuration of the QSP 100 Use the Logical Com Port name to access any of the particular serial ports on the QSP 100 This name is required by a Windows 95 application when accessing a particular port 22 4 3 Changing Configuration of the QSP 100 To change the hardware configuration of the QSP 100 follow the instructions below 1 Double click the My Computer icon located on the Windows 95 desktop 2 Double click on th
8. Driver reports Card and Socket Services not found a version of Card and Socket Services must be installed on the system or the QSP 100 Enabler program must be used to configure the adapter If the Client Driver reports the desired adapter configuration the installation process is complete and the QSP 100 may be removed and or inserted from the system as desired On each insertion into the PCMCIA socket the QSP 100 will be automatically re configured according to the command line options 2 1 2 Command Line Options The QSP 100 Client Driver accepts up to eight command line arguments from the user to determine the configuration of the QSP 100 If any arguments are provided the Client Driver will attempt to configure any QSP 100s with the options specified in the order they are entered on the command line Each argument must be enclosed in parenthesis and must be separated from other arguments by a space on the command line Within each argument any or all of the following parameters may be specified using a comma no spaces to separate each parameter Baddress specifies the base I O address of the QSP 100 in hexadecimal and must reside on an even 32 byte 20H boundary If this option is omitted a base address will be assigned by Card and Socket Services lirg specifies the interrupt level IRQ of the QSP 100 in decimal irq must be one of the following values 3 4 5 7 9 10 11 12 14 15 or 0 if no IRQ is desired If this opt
9. IRQ resources are available For OS 2 Warp users the RMVIEW utility may be useful in finding resource conflicts Type rmview at an OS 2 command prompt for details When using system assigned resources if the user knows the port number is available then the system may not have sufficient resources available to configure the QSP 100 Again the RMVIEW utility provided with OS 2 Warp may be useful in determining the problem Regardless of the configuration method each command line argument specifies the first of four COM ports for the QSP 100 If any of these COM ports are already installed the Client Driver will not load Parameter Overlapping When installing the QSP 100 each command line argument specifies the first of four COM ports If these arguments overlap the Client Driver will not load For example it is illegal to specify QSP100 SYS COM3 COM4 because the first argument requests COM3 COM6 and the second argument specifies COM4 COM7 Insufficient Number Of Command Line Arguments The QSP 100 command line must contain at least one command line argument for each QSP 100 to be installed QSP 100 User s Manual 19 4 Windows 95 Installation Windows 95 maintains a registry of all known hardware installed within the computer Inside this hardware registry Windows 95 keeps track of all the computer s resources such as base I O addresses IRQ levels and DMA channels In the case of aPC Card PCMCIA type board Wind
10. P100CL SYS File name QSP100EN EXE File type DOS device driver File type DOS executable Interfaces to PCMCIA Card and Interfaces directly to Intel 82365SL Socket Services software PCMCIA and other PCIC compatible host adapter independent PCMCIA host adapters Allows automatic configuration of Does not support automatic QSP 100 adapters upon insertion configuration of QSP 100 adapters Hot Swapping upon insertion Hot Swapping Requires PCMCIA Card and Socket Does not require PCMCIA Card and Services software Socket Services software Figure 1 Client Driver versus Enabler for DOS Windows 3 x Card and Socket Services software is commercially available from several vendors for most desktop and laptop PCs If you are unsure whether Card and Socket Services software is currently installed on your system install the QSP 100 Client Driver as discussed in following section When loaded the Client Driver will display an error message if Card and Socket Services software is not detected 2 1 QSP 100 Client Driver for DOS In order to use the QSP 100 Client Driver the system must be configured with Card and Socket Services software Card and Socket Services software is not provided with the QSP 100 but is available from Omega IMPORTANT Some versions of Card and Socket Services dated before 1993 do not support general purpose I O cards If after careful installation of the Client Driver the QSP 100 does not configure or ope
11. ailable address and IRQ resources the third command line argument will never be reached by the Client Driver It is the user s responsibility to place the command line arguments in a logical order 2 1 2 7 Example 7 DEVICE C QSP 100 QSP100CL SYS s0 b300 i5 s1 b340 i10 The type of configuration shown in example 7 may be desirable in systems where more than one QSP 100 is to be installed In this example the Client Driver will attempt to configure a QSP 100 inserted into socket 0 with a base address of 300H and IRQ 5 If the QSP 100 is inserted into socket 1 the Client Driver will attempt to configure it with base address 340H and IRQ 10 This allows the user to force the QSP 100 s address and IRQ settings to be socket specific which may simplify cable connections and software development As in the previous examples however if the requested address or interrupt resources are not available the QSP 100 will not be configured QSP 100 User s Manual 7 2 1 3 Common Problems Generic Client Drivers Many Card and Socket Services packages include a generic client driver or SuperClient which configures standard I O devices If one of these generic client drivers is installed it may configure the QSP 100 causing the QSP 100 client driver to fail installation In these cases the user should do one of the following 1 modify the operation of the generic client driver to disable the configuration of modem serial port cards Cons
12. ard and Socket Services may be required 2 2 QSP 100 Enabler for DOS For systems that are not operating PCMCIA Card and Socket Services software the QSP 100 DOS Enabler may be used to enable and configure the adapter This Enabler QSP100EN EXE will operate on any DOS system using an Intel 82365SL or PCIC compatible PCMCIA host adapter including the Cirrus Logic CL PD6710 6720 the VLSI VL82C146 and the Vadem VG 365 among others 7 IMPORTANT In order to use the QSP 100 Enabler for DOS the system MUST NOT be configured with Card and Socket Services software If a Card and Socket Services software is installed the QSP 100 Enabler may interfere with its operation and with the device s it controls The QSP 100 Enabler does not support automatic configuration of adapters upon insertion more commonly referred to as Hot Swapping This means the adapter must be installed in one of the system s PCMCIA sockets before executing QSP100EN EXE If more than one adapter is installed in a system the Enabler must be executed separately for each adapter Furthermore QSP100EN EXE should be executed to release the resources used by the adapter before it is removed from the PCMCIA socket Since PCMCIA adapters do not retain their configuration after removal any adapter that is removed from the system must be re configured with the Enabler after re inserting it into a PCMCIA socket IMPORTANT The Enabler requires a region of high
13. b300 In example 2 a single command line argument is provided The Client Driver will attempt to configure a QSP 100 inserted into any socket with a base address of 300H and an IRQ assigned by Card and Socket Services If address 300H is unavailable the QSP 100 will not be configured If the Client Driver can successfully configure the QSP 100 its interrupt status register will be enabled and the BIOS equipment list will not be updated QSP 100 User s Manual 5 2 1 2 3 Example 3 DEVICE C QSP 100 QSP100CL SYS s0 b300 i5 In example 3 a single command line argument is provided The Client Driver will attempt to configure a QSP 100 inserted into socket 0 with a base address of 300H and IRQ 5 If address 300H or IRQ 5 is unavailable the QSP 100 will not be configured In addition if a QSP 100 is inserted into any other socket it will not be configured If the Client Driver can successfully configure the QSP 100 its interrupt status register will be enabled and the BIOS equipment list will not be updated 2 1 2 4 Example 4 DEVICE C QSP 100 QSP100CL SYS i5 e u b300 In example 4 a single command line argument is provided Because the parameter order is not significant the Client Driver will attempt to configure a QSP 100 inserted into any socket with a base address of 300H and IRQ 5 If address 300H or IRQ 5 is unavailable the QSP 100 will not be configured If the Client Driver can successfully configure the QSP 100 its
14. cifies the base address of the memory window required to configure the QSP 100 Set address DO for a memory window at segment D000 address D8 for a memory window at segment D800 etc Valid settings for address are C8 CC DO D4 D8 and DC If this option is omitted a memory window at segment D000 will be used instructs the Enabler to disable the QSP 100 s interrupt status register and enable the Scratchpad registers of the individual UARTs This option is only required in very rare cases where an application program requires access to the UART s Scratchpad register If this option is omitted the QSP 100 s interrupt status register is enabled and the UARTs Scratchpad registers are disabled instructs the Enabler to update the BIOS equipment list with the addresses assigned to the QSP 100 This option is only required in very rare cases where an application program checks the BIOS equipment list to determine the address of a COM port If this option is omitted the BIOS equipment list is not updated 10 Before removing a QSP 100 from its PCMCIA socket the Enabler should be executed to free the system resources allocated when the card was installed For this operation the Enabler provides on additional command line option R instructs the Client Driver to release the resources previously allocated to the QSP 100 When the R option is used any settings specified by the B T U and E options are ignored This option m
15. e Control Panel icon 3 Double click the System icon inside the Control Panel folder This will open the System Properties box 4 Click the Device Manager tab located along the top of the System Properties box 5 Double click on the device group Omega Comm Adapters The QSP 100 model name should appear in this list If either the Omega Comm Adapters group or the QSP 100 model number does not appear contact Omega Technical Support for further assistance 6 Click on the QSP 100 item and then click on the button labeled Properties 7 Select the resource which requires a change I O range or IRQ and select Change Settings Make the desired changes and then click on OK A shutdown of the system may be required to allow the settings to change If prompted for a shutdown select the option which restarts Windows 95 8 The QSP 100 will be automatically re configured to the desired settings 9 The card is now ready for use QSP 100 User s Manual 23 5 Hardware Information The QSP 100 s four asynchronous serial ports are implemented using 4 standard 16C550 UARTs Each of these UARTs requires 8 bytes of I O space and when enabled QSP 100 RS 232 channel Address assignment Channel A Base Address 0 Channel B Base Address 8 Channel C Base Address 16 Channel D Base Address 24 which requires the QSP 100 to be located on an even 32 byte 20H boundary e g 300H 320H 340H etc
16. em assigned resources can be a problem however if DOS and or Windows applications will be accessing the serial ports This is because most DOS applications write directly to the communications hardware and the Windows Control Panel also wants to know the hardware configuration of the serial ports In these cases the user may want to configure the QSP 100 with user assigned resources 3 1 1 1 Example 1 DEVICE C QSP 100 QSP100 SYS COM3 In example 1 the Client Driver will attempt to configure the QSP 100 as COMS through COM6 If COM3 4 5 or 6 already exists in the system the QSP 100 will not be configured Furthermore only one QSP 100 can be installed in this system 3 1 1 2 Example 2 DEVICE C QSP 100 QSP100 SYS COM7 COM3 In example 2 the Client Driver will attempt to configure the QSP 100 as COMS through COM6 If COM3 4 5 or 6 already exists in the system the Client Driver will attempt to configure the QSP 100 as COM7 through COM10 If COM7 8 9 or 10 already exist in the system the QSP 100 will not be configured Up to two QSP 100s can be installed in this system OSP 100 User s Manual 15 3 1 2 Configuring With User Assigned Resources As mentioned in the previous section allowing the OS 2 Plug and Play system to assign the hardware resources to the QSP 100 is ideal for OS 2 programs but can be a problem if DOS and or Windows applications will be accessing the serial ports This is because most DOS applicatio
17. em has been configured to the above specifications the QSP 100 Client Driver may be installed with the following procedure 1 Copy the QSP100 SYS client driver file from the distribution disk to any convenient directory on the hard disk Open the CONFIG SYS file using any ASCII text editor Add the following line to the CONFIG SYS file DEVICE drive path QSP100 SYS options where options are the QSP 100 OS 2 Client Driver command line options discussed in the following sections Save the CONFIG SYS file exit the text editor shutdown the system and reboot to activate the changes 14 3 1 Command Line Options The QSP 100 Client Driver for OS 2 supports two methods of configuration using system assigned resources and using user assigned resources Both options provide full PCMCIA compliance and functionality including Hot swapping but each has some advantages and disadvantages as discussed in the following sections 3 1 1 Configuring With System Assigned Resources Allowing the OS 2 Plug and Play system to assign the hardware resources to the QSP 100 is the ideal choice when only OS 2 programs will access the serial ports When configuring the hardware the user simply specifies a list of COM port numbers When a QSP 100 is inserted into a PCMCIA socket the client driver will configure the card as a series of COM ports starting with the lowest available port number in the list Configuring a QSP 100 with syst
18. igured Furthermore only one QSP 100 can be installed in this system 16 3 1 2 2 Example 2 DEVICE C QSP 100 QSP100 SYS 7 120 15 3 300 4 In example 2 the Client Driver will attempt to configure the QSP 100 as COMS through COM6 using I O address 300 31F hex and IRQ 4 If COM3 4 5 or 6 already exists or if the I O address or IRQ resources are already in use the Client Driver will attempt to configure the QSP 100 as COM7 through COM10 using I O address 120 13F hex and IRQ 15 If COM7 8 9 or 10 already exists or if the I O address or IRQ resources are already in use the QSP 100 will not be configured Up to two QSP 100s can be installed in this system 3 1 3 Advanced Configuration Topics For some applications it may be desirable to specify the resources for one QSP 100 while allowing the OS 2 Plug and Play system to assign the hardware resources for any additional cards This can be accomplished by mixing the configuration methods on the QSP 100 Client Driver command line DEVICE C QSP 100 QSP100 SYS 3 100 5 COM7 It is important to remember that when a QSP 100 is inserted into a PCMCIA socket the client driver will configure the card as a series of COM ports starting with the lowest available port number in the list Another common application requirement is to have a QSP 100 inserted into socket 1 be configured as COM3 through COM6 while a QSP 100 inserted into socket 2 be configured as COM7 through COM10 This ty
19. ion is omitted an interrupt level will be assigned by Card and Socket Services Ssocket specifies which PCMCIA socket the QSP 100 must be inserted into for this configuration argument to be used socket must be in the range 0 15 If this option is omitted the configuration argument will apply to QSP 100s inserted into any socket U instructs the Client Driver to disable the QSP 100 s interrupt status register and enable the Scratchpad registers of the individual UARTs This option is only required in very rare cases where an application program requires access to the UART s Scratchpad register If this option is omitted the QSP 100 s interrupt status register is enabled and the UARTs Scratchpad registers are disabled E instructs the Client Driver to update the BIOS equipment list with the addresses assigned to the QSP 100 This option is only required in very rare cases where an application program checks the BIOS equipment list to determine the address of a COM port If this option is omitted the BIOS equipment list is not updated 2 1 2 1 Example 1 DEVICE C QSP 100 QSP100CL SYS In example 1 no command line arguments are specified The Client Driver will configure a QSP 100 inserted into any socket with a base address and IRQ assigned by Card and Socket Services The QSP 100 s interrupt status register will be enabled and the BIOS equipment list will not be updated 2 1 2 2 Example 2 DEVICE C QSP 100 QSP100CL SYS
20. nes 24 5 EXTERNAL CONNECTIONS The QSP 100 is fitted with a 33 pin 0 8mm shielded connector with the pins assigned as shown in the figure below A mating connector is available from AMP order part number 558126 4 20 25 30 33 RTS A RxD A DIR A CTS A DSR A DCD A TxD A RTS B RxD B DTR B CTS B DSR B DCD B TxD B RI B Signal Ground RTS RxD DTR CTS DSR DCD TxD RI C RTS RxD DTR CTS DSR DCD TxD RI D QSP 100 Aqaraan Vp DUD UD Figure 2 QSP 100 output connector QSP 100 User s Manual 25 An adapter cable is included with the QSP 100 to convert the 33 pin 0 8mm output connector into 4 standard D 9 male RS 232 connectors as shown in the figure below Port A Port B Port C Port D Figure 3 QSP 100 adapter cable to standard RS 232 connectors JOGOO 219919 Figure 4 Standard D 9 male RS 232 connector signal assignment 26 6 Specifications Bus Interface Physical Dimensions Maximum Baud Rate Power Requirements Connector PCMCIA PC Card Standard 2 1 compliant Type II PCMCIA card 5mm 120K 5 volts 35 85 mA typical 45 87 mA maximum Adapter to 4 standard male D 9 QSP 100 User s Manual 27
21. ns write directly to the communications hardware and the Windows Control Panel also wants to know the hardware configuration of the serial ports For this reason the QSP 100 Client Driver allows the user to request specific hardware settings using a series of command line arguments of the form port address irq port specifies the beginning COM port number address specifies the base I O address of the QSP 100 in hexadecimal and must reside on an even 32 byte 20H boundary irq specifies the interrupt level IRQ of the QSP 100 in decimal irq must be one of the following values 3 4 5 7 9 10 11 12 14 or 15 Each argument must be enclosed in parentheses and must be separated from other arguments by a space on the command line Within each argument the parameters must be separated using a comma no spaces When a QSP 100 is inserted into a PCMCIA socket the client driver will configure the card as a series of COM ports starting with the lowest available port number in the list IMPORTANT If the user specified resources are in use by other devices in the system the QSP 100 will not be configured 3 1 2 1 Example 1 DEVICE C QSP 100 QSP100 SYS 3 100 5 In example 1 the Client Driver will attempt to configure the QSP 100 as COMS through COM6 using I O addresses 100 11F hex and IRQ 5 If COM3 4 5 or 6 already exists or if the I O address or IRQ resources are already in use the QSP 100 will not be conf
22. number in the system is designated socket 0 Card and Socket Services Software In order to use the QSP 100 Enabler for DOS the system MUST NOT be configured with Card and Socket Services software If a Card and Socket Services software is installed the QSP 100 Enabler may interfere with its operation and with the device s it controls For systems configured with Card and Socket Services the QSP 100 Client Driver is the recommended method of configuration QSP 100 User s Manual 13 3 OS 2 Installation In order to use the QSP 100 Client Driver for OS 2 the system must be configured as follows 1 2 The system must be running OS 2 2 1 or later OS 2 PCMCIA Card and Socket Services support must be installed If PCMCIA support was not selected when OS 2 was installed it can be added using the Selective Install facility in the System Setup folder On OS 2 2 1 and 2 11 Socket Services must be added separately The necessary files can be found on Compuserve in the OS2SUPPORT forum and may be available elsewhere These files are not available from Omega Inc Omega s OS 2 serial port device driver QCOM version 2 01 or later must be installed The QSP 100 will not operate with the standard OS 2 serial port device drivers Omega Inc can not guarantee the operation of the QSP 100 with any other third party device drivers for OS 2 There must be at least 32 bytes of available I O space and 1 available IRQ After the syst
23. ows 95 configures the new hardware using free resources it finds within the hardware registry and updates the registry automatically Windows 95 handles the QSP 100 as a parent child device The QSP 100 is the parent device Each serial port is a child device of the parent device QSP 100 To allow easy configuration of Omega s QSP 100 two configuration files have been written for the QSP 100 These files are called INF files The OSP 100 INF file describes the resources of the QSP 100 parent device It also indicates the number of child devices There are 4 child COM ports for the QSP 100 The MLTPT_SP INF file describes the settings for each serial port including all the necessary device drivers Windows 95 allows changes in the system resources if the default choices are unacceptable But first allow Windows 95 to configure all of the devices Since the child COM ports are dependent on the parent devices resource allocations the resources can only be modified at the parent device Changing these resources is an easy task described in a later section 20 4 1 Installing a QSP 100 Under Windows 95 1 Insert the QSP 100 into any available PC Card socket 2 The first time a new PC Card type is installed the New Hardware Found window opens After this first installation Windows 95 will automatically detect and configure the card If the New Hardware Found window does not open then skip to the next section Viewing the
24. pe of configuration is supported by appending a Sx parameter after any command line argument DEVICE C QSP 100 QSP100 SYS COM3 S1 COM7 S2 DEVICE C QSP 100 QSP100 SYS 3 100 4 S1 7 300 3 S2 QSP 100 User s Manual 17 3 2 Monitoring The Status Of PCMCIA Cards OS 2 Warp provides a utility called Plug and Play for PCMCIA that can be used to monitor the status of each PCMCIA socket In OS 2 2 1 this utility is called Configuration Manager When a QSP 100 is inserted the Card Type for the appropriate socket will display Multi Function If the card is successfully configured the Card Status will display Ready If the card cannot be configured the Card Status will be Not Ready You can view the resources claimed by a configured card by double clicking on that card s line in the window 18 3 3 Common Problems Invalid I O Address When Using OS 2 2 1 PCMCIA Card Services for OS 2 2 1 sometimes fails to supply a valid I O address when using system assigned resources Use the Configuration Manager program to examine the I O address range assigned to the QSP 100 If this range does not begin on an even 32 byte 20H boundary the QSP 100 will have to be installed using user assigned resources to force a valid configuration There have not been any reports of this problem with OS 2 Warp Resources Not Available When using user assigned resources it is the user s responsibility to ensure the I O address and
25. rate properly an updated version of Card and Socket Services may be required 2 1 1 Client Driver Installation The following procedure is used to install the QSP 100 Client Driver 1 Copy the file QSP100CL SYS from the QSP 100 distribution diskette onto the system s hard drive Using an ASCII text editor open the system s CONFIG SYS file located in the root directory of the boot drive Locate the line s in the CONFIG SYS file where the Card and Socket Services software is installed AFTER the line s installing the Card and Socket Services software add the following line to the CONFIG SYS file DEVICE drive path QSP100CL SYS options where options are the QSP 100 Client Driver command line options discussed on the following pages Save the CONFIG SYS file and exit the text editor QSP 100 User s Manual 6 Insert the QSP 100 into one of the system s PCMCIA slots NOTE Since the QSP 100 Client Driver supports Hot Swapping it is not necessary to have the QSP 100 installed when booting the system By inserting the card before booting however the Client Driver will report the adapter configuration during the boot process thereby verifying the changes made to the CONFIG SYS 7 Reboot the system and note the message displayed when the QSP 100 Client Driver is loaded If the Client Driver reports an invalid command line option correct the entry in the CONFIG SYS file and reboot the system again If the Client
26. ult the Card and Socket Services documentation for availability and details of this feature 2 place the QSP 100 client driver before the generic client driver in the CONFIG SYS Available Resources One function of the Card and Socket Services software is to track which system resources memory addresses I O addresses IRQs etc are available for assignment to inserted PCMCIA cards Sometimes however the Card Services software assumes or incorrectly determines that a particular resource is used when it is actually available Most Card and Socket Services generate a resource table in a file typically in the form of an INI file which the user can modify to adjust the available system resources Consult the Card and Socket Services documentation for availability and details of this feature Multiple Configuration Attempts Some Card and Socket Services have a setting which aborts the configuration process after a single configuration failure such as a request for an unavailable resource The user should change this setting to allow for multiple configuration attempts Consult the Card and Socket Services documentation for availability and details of this feature Older Versions of Card and Socket Services Some versions of Card and Socket Services dated before 1993 do not support general purpose I O cards If after careful installation of the Client Driver the QSP 100 does not configure or operate properly an updated version of C
27. ust be omitted when installing a QSP 100 into the system 2 2 1 1 Example 1 QSP100EN EXE In example 1 no command line argument is specified The Enabler will report an error and display the proper usage of the command 2 2 1 2 Example 2 QSP100EN EXE s0 b300 i5 In example 2 the Enabler will configure the QSP 100 in socket 0 with a base address of 300H and IRQ 5 using a configuration memory window at segment D000 The QSP 100 s interrupt status register will be enabled and the BIOS equipment list will not be updated 2 2 1 3 Example 3 QSP100EN EXE i10 e u b340 s1 In example 3 the Enabler will configure the QSP 100 in socket 1 with a base address of 340H and IRQ 10 using a configuration memory window at segment D000 The QSP 100 s interrupt status register will be disabled Scratchpad registers enabled and the BIOS equipment list will be updated Note that the parameter order is not significant QSP 100 User s Manual 11 2 2 1 4 Example 4 QSP100EN EXE s0 b300 i3 wd8 In example 4 the Enabler will configure the QSP 100 in socket 0 with a base address of 300H and IRQ 3 using a configuration memory window at segment D800 The QSP 100 s interrupt status register will be enabled and the BIOS equipment list will not be updated 2 2 1 5 Example 5 QSP100EN EXE s0 b300 i5 r In example 5 the Enabler will release the configuration used by the QSP 100 in socket 0 using a configuration memory window at segment D0