1. sterilised in any other way than what is described above The drive must not be lubricated with oil This can otherwise lead to operative damage and downtime and is not recognised by the manufacturer as a customer complaint 959 8 Failure malfunction repairs customer complaints When device malfunctions occur you should first of all disconnect all components such as power supply unit and the hand piece from the device After you have checked all of the connections and reconnected them the device should work again If the malfunction of the device cannot be resolved then the device should be given to an authorised dealer Customer complaints are to be made to the dealer For the disposal the device must be sent back to the manufacturer Please contact your distributor on this matter WWW CHEYENNE TATTOO COM 21 MEDIZINGER TE 9 Scope of delivery Art No Article Scope of delivery CB 2 25 Cheyenne Hawk spirit Tattoo Machine 1 GCB 2 1 1 Connecting Cable for the Machine 1 0303 130 1 Liner Tattoo Needle Head b E 0309 F30 9 Flat Tattoo Needle Head 1 E 0313 F30 13 Flat Tattoo Needle Head 1 GCB 2 1 4 Adapter 1 7 2 25 Manual 1 If you need any further information on our current offers and selection of needle heads available then please do contact us at www cheyenne tattoo com oo 10 Warranty declaration With this device you have bought
2. t vibrate as much It does however have at its disposal a much more powerful puncturing capability and punctur ing rate than conventional devices The danger at the start is always that one tattoos much too deeply due to the running smoothness or sets the speed way too high and thereby cuts open the skin The Cheyenne Hawk spirit is only allowed to be used by experienced tattooists whereby a briefing by the Cheyenne tattooists is definitely recommended If you have any questions please use the con tact data at www cheyenne tattoo com 1 1 Manual This manual points out what the intended application of the tattoo device is and serves to prevent accidents and annul dangers This manual must be read and observed by all individuals that use ap ply maintain service or clean this device This manual is a part of the device as a whole and must be made available at all times to the person using or applying it If the device is passed on to third parties then the manual must be included in this transaction 1 2 Basics The Cheyenne Hawk spirit is only allowed to be used and operated by authorised or trained profes sional personnel and is only allowed to be used and operated for the purposes stated in this manual This manual does in no way replace the required training course that is necessary The contraindications in chapter 4 have to be observed at all times The user is obliged to comply with the basic hygienic and cleanliness s
3. Pflegearbeiten ist die Maschine vom Anschlusskabel 8 abzuziehen Die Maschine ist nach jedem Gebrauch zu reinigen Dabei soll nach folgendem Schema vorgegangen werden s Aufbauzeichnung Das Stromversorgungsger t abschalten Die Maschine vom Anschlusskabel 8 trennen Den Nadelkopf 1 aus der Maschine herausschrauben Die Fixiermutter 2 l sen abschrauben und die Griffh lse 4 vorsichtig vom Antrieb 6 trennen Dabei darauf achten dass der Pleuel 3 nicht verbogen wird 5 Den Antrieb 6 mit einem weichen Tuch und einem milden Desinfektionsmittel z B 50 ge w ssrige 1 reinigen 6 Die Griffh lse 4 ist nach Gebrauch zu autoklavieren Es d rfen ausschlie lich Sterilisatoren mit Vorvakuum verwendet werden Bei Verwendung eines Hei luftautoklaven kann es zu Ver nderung der Oberfl che der Griffh lse 4 kommen Dies hat keinen Einfluss auf die Funktion der Maschine trotzdem werden vom Hersteller daher Dampfsterilisatoren empfoh len 7 Bei sehr starker Verschmutzung die durch normalen Reinigungsaufwand nicht entfernt wer den kann ist die Griffh lse 4 in einem Ultraschallbad zu reinigen Dabei d rfen nur die Reiniger Tickomed 1 3 oder Tickopur R33 3 verwendet werden a Achtung Der Antrieb 6 darf nicht autoklaviert oder anders als oben beschrieben desinfiziert werden Der Antrieb darf ebenso nicht ge lt werden Dies f hrt zu Funktionsausfall und wird vom Hersteller n
4. ZUSAMMENBAU 11 8 FUNKTIONSAUSFALL REPARATUREN REKLAMATION 11 9 LIEFERUMFANG 2 2 11 10 GARANTIEERKL RUNG eeseesessesseseoseosesecsecssoscosessoseosesscoecseoscosesecsecseoscosesse 12 11 TECHNISCHE PARAMETER ae 12 12 TRANSPORT UND 13 1 ADRE SEN EAEE 13 20 14 Version 1 6 05 2011 WWW CHEYENNE TATTOO COM 3 MEDIZINGER TE Table of Contents 1 1 1 1 2 1 3 2 3 AREAS OF APPLICATION 4 5 6 6 1 6 2 6 3 6 4 6 5 6 6 MAINTENANCE STERILISATION 21 FAILURE MALFUNCTION REPAIRS CUSTOMER COMPLAINTS 21 SCOPE OF DELIVERY 22 2 kein 22 10 WARRANTY DECLARATION nenn aa 22 11 TECHNICAL KR SRA UNO Le 22 12 TRANSPORT AND STORAGE CONDITIONS 23 13 ADDRESSES Seesen 23 14 AUXILIARY aaa 24 Version 1 6 05 2011 MT DERM GmbH CHEYENNE Herzlichen Gl ckwunsch zum Kauf Ihrer neuen Cheyenne Hawk spirit Die Hawk spirit ist eine Hochleistungs Tattoo Maschine dessen Eigenschaften in mehrj hriger Ent wicklung von Ingenieuren und T towierern optimiert wurden F r eine einwandfreie Handhabung lesen Sie bitte die Gebrauchsanweisung vor der ersten Inbetrieb nahme sorgf ltig durch So werden Sie u a ein besseres Verst ndnis f r die technischen Funktionen und Einsatzm gli
5. device a visual inspection has to be undertaken in order to as certain if any transport damage has occurred If one can assume that the device cannot be operated safely anymore then it must be put out of commission and safeguarded against accidental or unau thorised use 13 Addresses Manufacturer MT DERM GmbH Gustav Krone Str 3 14167 Berlin Germany WWW CHEYENNE TATTOO COM 23 MEDIZINGER TE 14 Auxiliary equipment 14 1 The Cheyenne Hawk spirit was especially developed for use with the control unit PU II also manu factured by Cheyenne 14 2 Handle piece for the Hawk spirit For efficient work on multiple customers a separate handle piece for the Hawk spirit is available Handle piece for the Hawk spirit Further information on the Hawk spirit and details to dealers can be found at www cheyenne tattoo com 24 MT DERM GmbH CHEYENNE Notizen notes WWW CHEYENNE TATTOO COM 25 MEDIZINGER TE Notizen notes 26 MT DERM GmbH CHEYENNE Notizen notes WWW CHEYENNE TATTOO COM 27 GmbH Gustav Krone Str 3 14167 Berlin fon 49 0 30 845885 4 e mail info cheyenne tattoo com web www cheyenne tattoo com
6. DERM GmbH iist zertifiziert nach e DIN EN ISO 9001 2008 Qualit tsmanagement System zur Qualit tssicherung DIN EN ISO 13485 2007 Qualit tsmanagement System f r Medizinprodukte F r das Ger t gilt die gesetzliche Gew hrleistung von 2 Jahren auf Ger test rungen welche auf Ma terialfehler oder Verarbeitungsm ngel zur ckzuf hren sind F r Folgesch den wird keine Haftung bernommen F r Sch den die auf unsachgem e Behandlung oder Nichtbeachtung der Gebrauchs anweisung zur ckzuf hren sind werden grunds tzlich keine Gew hrleistungen bernommen 99 11 Technische Parameter Ger tetyp Cheyenne Hawk spirit Nennspannung 5 12 VDC Leistungsaufnahme 15 VA Arbeitsfrequenz 50 150 Stiche pro Sekunde Antrieb Pr zisionsmotor DC 12V Betriebsart Dauerbetrieb 12 MT DERM GmbH CHEYENNE Betriebsbedingunge Umgebungstemperatur 10 C bis 35 C relative Luftfeuchte 30 bis 75 Abmessungen Breite x H he x Tiefe 110 x 75 x 28 mm Gewicht des Handst cks ca 120 g Ger t entspricht den Anforderungen der Richtlinie 89 336 EWG EMV Richtlinie A Gebrauchsanweisung beachten 12 Transport und Lagerbedingungen Umgebungstemperatur 40 C bis 40 C relative Luftfeuchte 30 bis 75 90 Luftdruck 500 hPa bis 1060 hPa Vor Inbetriebnahme des Ger tes muss eine Sichtko
7. Hawk spirit GEBRAUCHSANWEISUNG MANUAL CHEYENNE Aufbau der Cheyenne Hawk spirit Construction design of Abb 1 Aufbauzeichnung Cheyenne Hawk spirit 1 Nadelkopf Modul 2 Fixiermutter 3 Pleuel 4 Griffhiilse 5 Index 6 Antrieb 7 Gleichstromanschluss max 12V 8 Anschlusskabel Cheyenne Hawk spirit Illustration 1 Construction design of the Cheyenne Hawk spirit 1 Needle head module 2 Fixing nut 3 Conrod 4 Grip sleeve 5 Index 6 Drive 7 Direct current connection max 12V 8 Connecting cable MT DERM GmbH CHEYENNE Inhalt 1 ALLGEMEINE KUN DK GA 5 1 1 GEBRAUCHSANWEISUNG re unsere aussah hassen akre EEEa 5 1 2 GRUNDL GEN AAE 5 1 3 TECHNISCHER FORTSCHRITT sepes adesa Reis REIHE 6 SARRAILAN KO PAA 6 3 ANWENDUNGSBEREICHE u 6 4 KONTRAINDIKATIONEN 2 ee 6 5 WICHTIGE HYGIENE UND SICHERHEITSHINWEISE 7 REO KIG BARIAIN EA PROSA UPA 8 6 1 GERATEAUFSTE ARIAS 8 6 2 GER TE NSCHLUSS E 8 6 3 BADEK OEE eretan E E E E a e Gra e 9 6 4 REGULIERUNG DER STICHFREQUENZ 10 6 5 SICHERHEITSHINWEISE ZUM NADELKOPF aa 10 6 6 PANTRIEB i ra a a sanctions ceases 10 7 WARTUNG STERILISATION
8. a high quality brand product The reliability of the device is guar anteed by the newest test techniques as well as certification MT DERM GmbH has been certi fied in accordance with DIN EN ISO 9001 2008 Quality management system for quality assurance DIN EN ISO 13485 2007 Quality management system for medical products The legal warranty for this device is 2 years for malfunctions that have to do with faulty material or manufacturing defects No liability is assumed for any subsequent damage For damage that is due to improper handling or not following the manual instructions no warranty is assumed ooo 11 Technical parameters Device type Cheyenne Hawk spirit Nominal voltage 5 12 V DC Input power consumption 15 VA Operational rate 50 150 punctures per second Drive Precision motor DC 12 V Operational mode Continuous long term operation 22 MT DERM GmbH CHEYENNE Operational requirements Ambient temperature 10 C to 35 C Relative humidity 30 to 75 Measurements T Weight of the handpiece 120 Device complies with requirements of Di rective 89 336 EEC EMC Directive Please adhere to manual 12 Transport and storage conditions Ambient temperature 40 C to 40 C Relative humidity 30 to 75 Air pressure 500 hPa to 1060 hPa Before the start of operation with the
9. abfall zu entsorgen Zur ordnungsgem en Entsorgung sind die lokalen Bestimmungen zu beachten Achtung Verletzungsgefahr Im Nadelkopf befinden sich Nadeln die bei unsachgem er Handhabung zu Verletzungen f hren k nnen daher sollten niemals e Nadeln von hinten am Nadelschaft aus dem Nadelkopf herausgedr ckt und Nadelspitzen bei eingeschaltetem Handst ck ber hrt werden Eine Verletzung mit einer kontaminierten Nadel kann die bertragung von gef hrlichen Krankheiten zur Folge haben In diesem Fall sollte sofort ein Arzt aufgesucht werden Das Handst ck sowie die Handst ckablage m ssen unmittelbar vor Gebrauch bzw vor der Behand lung durch Abwischen mit einem Desinfektions und Reinigungsmittel getr nkten weichen Tuch gereinigt werden Das Handst ck und das Steuerger t d rfen niemals in Desinfektionsmittel getr nkt werden da sonst die Teile im Inneren korrodieren k nnen Vor der Anwendung muss das Steuerge r t das Handst ck das Handst ckkabel sowie die Handst ckablage mit einer Schutzfolie bzw ei nem Schutzschlauch versehen werden WWW CHEYENNE TATTOO COM 7 MEDIZINGER TE Das T towieren muss in einem sauberen Raum stattfinden wobei auf ein striktes Rauchverbot ge achtet werden muss Bitte beachten Sie hierf r die lokalen Bestimmungen zur Arbeitsplatzgestal tung Achtung Es d rfen nur dermatologisch unbedenkliche und f r den jeweiligen Anwendungs zweck vorgesehene Farben
10. chkeiten der Hawk spirit erlangen 1 Allgemeine Hinweise Gegen ber herk mmlichen Tattoo Ger ten ist die Cheyenne Hawk spirit erheblich leiser und vibra tions rmer Dennoch verf gt sie ber eine wesentlich h here Einstichkraft und Stichfrequenz als herk mmliche Ger te Es besteht gerade am Anfang die Gefahr dass man bedingt durch die Laufru he zu tief t towiert oder die Geschwindigkeit zu hoch einstellt und somit die Haut aufschneidet Die Cheyenne Hawk spirit darf nur von erfahrenden T towierern benutzt werden wobei eine Ein weisung durch die T towierer von Cheyenne unbedingt zu empfehlen ist Bei Fragen nehmen Sie bitte Kontakt unter www cheyenne tattoo com auf 1 1 Gebrauchsanweisung Diese Gebrauchsanweisung weist auf die bestimmungsgem e Anwendung des Tattoo Ger tes hin und dient zur Verh tung von Gefahren Sie muss von allen Personen gelesen und beachtet werden die dieses Ger t einsetzen bzw anwenden pflegen oder warten Diese Gebrauchsanweisung ist Bestandteil des Ger tes und muss dem Anwender st ndig zur Verf gung stehen Bei Weitergabe des Ger tes an Dritte ist sie mit dem Ger t zu bergeben 1 2 Grundlagen Die Cheyenne Hawk spirit darf nur von autorisiertem bzw geschultem Fachpersonal und nur f r den in dieser Gebrauchsanweisung genannten Zweck betrieben werden Diese Gebrauchsanweisung er setzt nicht eine unbedingt erforderliche Schulung Die Kontraindikationen aus Kapitel 4 sind
11. dem Aufschrauben der si chere Sitz des Nadelkopfes am Handst ck zu pr fen WWW CHEYENNE TATTOO COM 9 MEDIZINGER TE Die Einstellung des Nadelherausstands muss stets der laufenden Maschine vorgenommen werden Durch Drehen der Griffh lse 4 s Abb 1 l sst sich der f r den jeweiligen Einsatzzweck optimale Nadelherausstand einstellen Der richtige Nadelherausstand unterscheidet sich bez glich der jeweili gen Anwendung des Hauttyps dem gew nschten Effekt und anderen Faktoren Das Wissen hier ber muss in einer Schulung erworben werden Unmittelbar vor der Anwendung soll die Nadelkopfspitze f r 2 bis 3 Sekunden in die Farbe einge taucht werden Die Farbe wird bei eingeschalteter Maschine angesaugt Ber hrungen mit dem Farb beh lter sind dabei zu vermeiden 95 6 4 Regulierung der Stichfrequenz Bei Verwendung mit der Cheyenne PU II l sst sich die Stichfrequenz im eingeschalteten Zustand in 10 Stufen von 50 bis 150Hz ber die 4 Taste schneller und die W Taste langsamer einstel len Wird die Hawk spirit nicht mit der PU II verwendet ist die Stichfrequenz direkt von der Betriebs spannung abh ngig Die empfohlene Betriebsspannungsbereich liegt zwischen 6V und 12V Dieses Spannungsbereich entspricht der Stichfrequenz zwischen 50Hz und 150Hz Stiche pro Sekunde Z B entsprechen 11V ca 140Hz Stiche pro Sekunde Die Cheyenne Hawk spirit ist nun einsatzbereit 6 5 Siche
12. h contaminated objects e g with clothing etc If this does happen then a new sterile needle head is to be used After the treatment the needle heads are to be disposed of in a safety box as hospital waste For the proper waste disposal management the local and national regulations are to be complied with Warning risk of injury In the needle head there are needles that can lead to injury if not dealt with or handled properly Therefore the following should never be done needles that are pressed out of needle head from the back at needle shaft and needle heads that are touched during operation of the handpiece Injuring oneself with a contaminated needle can lead to the transmission of dangerous diseases In such a case a doctor should be immediately consulted The handpiece as well as the handpiece storage equipment must be cleaned immediately before use or before the treatment by wiping over said objects with a soft cloth that has been soaked with disin fectant and cleaning agent The handpiece and the control unit are not allowed to ever be soaked in disinfectants as otherwise internal parts might start corroding Before use the control unit the hand piece the handpiece cable as well as the handpiece storage equipment must be covered with a pro tective cloth or sheet or with a protective sleeve or tube WWW CHEYENNE TATTOO COM 17 MEDIZINGER TE The tattooing must take place in a clean r
13. i tional adapter not illustrated is supplied The connecting cable 8 is supposed to be plugged into the direct current voltage connection 7 of the machine until it locks in place The red banana plug of the adapter is to be connected to the positive pole and the black banana plug to the minus pole of the device Afterwards the adapter is to be connected with the connection cable 8 Warning The machine is safeguarded against polarity or current reversal as well as overvolt age If it comes to a current reversal or overvoltage voltage higher than 12V the machine cannot be operated It stays turned off In the case of polarity reversal when it comes to the connector the plugs at the power supply unit have to be switched red black In the case of overvoltage taking place the voltage has to be decreased After this procedure the machine can be operated once again In addition one should make sure that the cable for the handpiece is not bent or folded Safe operation is not guaranteed if the device or the auxiliary equipment is clearly and markedly damaged the device does not work as it should it has been stored for a longer period of time not within the specified temperature range it has been damaged due to improper transport 18 MT DERM GmbH CHEYENNE In these cases the device should be given to an authorised dealer so that it can be properly checked 95 6 3 Needle head When using the needle head 1 see i
14. icht als Reklamationsgrund anerkannt 8 Funktionsausfall Reparaturen Reklamation Bei Funktionsst rungen des Ger tes sollten Sie zun chst alle Komponenten wie Netzteil und Hand st ck vom Ger t trennen Nachdem Sie alle Anschl sse berpr ft und neu angeschlossen haben soll te das Ger t wieder funktionieren Sollte sich die Funktionsst rung nicht beseitigen lassen ist das Ger t einem autorisierten Fachh nd ler vorzustellen Zur Entsorgung muss das Ger t an den Hersteller zur ck Reklamationen sind beim Fachh ndler geltend zu machen geschickt werden Kontaktieren Sie hierzu Ihren Vertriebspartner WWW CHEYENNE TATTOO COM 11 MEDIZINGER TE 9 Lieferumfang Art Nr Artikel Lieferumfang CB 2 25 Cheyenne Hawk spirit Tattoo Maschine 1 GCB 2 1 1 Anschlusskabel f r die Maschine 1 0303 130 3er Liner Tattoo Nadelkopf 1 E 0309 F30 9er Flat Tattoo Nadelkopf 1 E 0313 F30 1361 Flat Tattoo Nadelkopf 1 GCB 2 1 4 Adapter 1 7E CB2 25 Gebrauchsanweisung 1 Wenn Sie weitere Informationen zu unseren aktuellen Angeboten und der Auswahl an Nadelk pfen ben tigen nehmen Sie bitte Kontakt mit uns unter www cheyenne tattoo com auf oo 10 Garantieerkl rung Mit diesem Ger t haben Sie ein qualitativ hochwertiges Markenprodukt erworben Die Zuverl ssig keit des Ger tes wird durch die neuesten Pr ftechniken und die Zertifizierung gew hrleistet MT
15. irectly dependent on the oper ating voltage The recommended operating voltage range lies between 6V and 12V This voltage range corresponds with a puncture rate of between 50Hz and 150Hz punctures per second For ex ample 11V are about 140Hz punctures per second The Cheyenne Hawk spirit is now ready to be used oo 6 5 Safety instructions for the needle head In order to remove the needle head the machine must be switched off When unscrewing the needle head one should make sure that any rest or surplus colour does not run into the machine After the taking off it has to be ensured that the needle is completely immersed in the head in order to avoid any injury On the sterile packaged needle heads a label can be found with the lot number as well as the manu facturing and use by date The lot number serves to clearly identify the charge and when problems occur must be reported to the manufacturer When adhering to the transport and storage specifications listed in chapter 13 the manufacturer of the needle heads guarantees the sterility if the packages remain closed and undamaged for a period of 5 years The unused needle heads must be kept in the box of 10 95 6 6 Drive The machine especially the drive 6 see construction design that is located within it is mechani cal precision instrument that is not allowed to be contaminated Due to this no colour is allowed to enter the drive region The needle head 1 has a built in f
16. llustration 1 one definitely has to take note of Chapter 5 Important hygiene and safety instructions Illustration 2 Needle head usage The needle head is screwed onto the machine During this procedure the machine has to be switched off Directly after screwing on the needle head the secure fastening of the needle head on the hand piece has to be tested The setting of how far the needle sticks out always has to be adjusted when the machine is in opera tion By turning the grip sleeve 4 see Illustration 1 one can set the optimal sticking out of the nee dle for the different and individual applications and uses The right length of the needle sticking out WWW CHEYENNE TATTOO COM 19 MEDIZINGER TE is different for each application and depends skin type desired effect as well as other fac tors Knowledge on this topic has to be gained during training courses Just before application the needle head top must be dipped into the colour for 2 to 3 seconds The colour is sucked in whilst the machine is in operation Touching the colour holder and reservoir is to be avoided at all times oo 6 4 Regulating the puncture rate When using with the Cheyenne PU II the puncture rate can be set when on in 10 different steps from 50 to 150Hz using the A button faster and the 7 button slower If the Hawk spirit is not used with the PU II then the puncture rate is d
17. lowback safety system which stops colours from entering the machine Damage that can be traced back to the entry of colours into the drive will not be recognised by the manufacturer as a customer complaint oo 20 MT DERM GmbH CHEYENNE 7 Maintenance sterilisation assembly Before starting with any cleaning or maintenance work the connecting cable 8 is to be unplugged from the machine The machine has to be cleaned after every usage Thereby one should adhere to the following steps see construction design Switch off the power supply unit Unplug the connecting cable from the machine 8 Unscrew the needle head 1 from the machine Loosen the fixing nut 2 screw off and carefully separate the grip sleeve 4 from the drive 6 Please make sure that the conrod 3 is not bent 5 Clean the drive 6 with a soft cloth and a mild disinfectant for example 50 water 1 propanol solution 6 The grip sleeve 4 has to be autoclaved after usage Only steam autoclave sterilisers are to be used When using a hot air steriliser changes on the surface of the grip sleeve 4 can occur This has no influence whatsoever on the function of the machine 7 For strong contamination which cannot be removed with general cleaning the grip sleeve 4 can be cleaned in an ultrasonic bath For this only Tickomed 1 3 or Tickopur R33 3 are allowed as cleaning agent Warning The drive 6 is not allowed to be autoclaved
18. n W hrend der ersten 4 bis 6 Wochen nach dem Stechen nimmt die Intensit t der eingebrachten Farbe auf das dauerhafte Niveau ab Dies ist normal da sich die Epidermis Oberhaut erneuert und die Pigmente in diesem Bereich herauswachsen Die verbleibende sichtbare Farbe ist somit unter der Epidermis Die Dicke der Epidermis ist individuell unterschiedlich und h ngt auch von der K rper region ab 95 3 Anwendungsbereiche Die Cheyenne Hawk spirit wird f r K rpert towierung bei Menschen verwendet T towierungen im Gesicht und bei Minderj hrigen sind nicht zul ssig oo 4 Kontraindikationen Es d rfen keine T towierungen an Personen unter den folgenden Bedingungen vorgenommen wer den Bluterkrankheit Infektionskrankheiten Alkohol Drogeneinfluss Angeborene Herzfehler Diabetes Zuckerkrankheit Allergien Hautanomalien im zu pigmentierenden Bereich Schwangerschaft Einnahme bestimmter Medikamente konsultieren Sie den verschreibenden Arzt Kelloidenbildung MT DERM GmbH CHEYENNE Achtung Besteht der geringste Zweifel an der Sicherheit f r den Kunden so darf mit der Be handlung nicht begonnen werden bzw ist die Behandlung sofort abzubrechen und die Freiga be eines Arztes einzuholen Die Behandlung muss sofort unterbrochen werden bei e berm igem Schmerzempfinden e berm igen Austreten von Wundfl ssigkeiten e Ohnmachtsanf llen Schwindelgef hl 959 5 Wichtige Hygiene und Sicherhei
19. n type the sun exposure the depth of the pigmentation as well as other factors During the first 4 to 6 weeks after the tattooing the intensity of the inserted colour drops to the long term level This is normal as the epidermis upper layer of skin renews itself and the pig ments in this area grow out of it The remaining viewable colour is therefore located under the epi dermis The thickness of the epidermis is different for every individual and also depends on the re gion of the one is talking about oo 3 Areas of application The Cheyenne Hawk spirit is used for tattooing body parts on people However facial tattoos as well as tattooing underage children or minors is not allowed oo 4 Contraindications No tattooing is permissible on individuals if the following conditions apply or are in any way rele vant Blood diseases and disorders Infections and infection related diseases Under the influence of alcohol drugs Born with cardiac defect congenital heart defect Diabetes Allergies Skin anomalies in the area which is to be pigmented Pregnancy Taking certain medication please consult the doctor prescribing the medication Kelloid Formation 16 MT DERM GmbH CHEYENNE Note If there is any doubt at all as to the safety or well being of the client then one is not al lowed to start with the procedure or the procedure is to be stopped immediately if already in effect A doctor has to be consulted and app
20. ntrolle durchgef hrt werden um Transportsch den sofort festzustellen Wenn anzunehmen ist dass das Ger t nicht mehr gefahrlos betrieben wer den kann ist es au er Betrieb zu nehmen und gegen unbeabsichtigtes oder unbefugtes Benutzen zu sichern 13 Adressen Hersteller MT DERM GmbH Gustav Krone Str 3 14167 Berlin Germany WWW CHEYENNE TATTOO COM 13 MEDIZINGER TE 14 Zubeh r 14 1 Die Cheyenne Hawk spirit wurde speziell f r die Verwendung mit dem Steuerger t PU II von Cheyenne entwickelt 14 2 Griffst ck f r die Hawk spirit F r das z gige Arbeiten an mehreren Kunden in schneller Folge kann ein zus tzliches Griffst ck erworben werden Griffst ck f r die Hawk spirit Weitere Informationen zur Hawk spirit und Hinweise zu H ndlern finden Sie unter www cheyenne tattoo com 14 MT DERM GmbH CHEYENNE Congratulations on purchasing your new Cheyenne Hawk spirit This Hawk spirit is a high performance tattoo machine whose features have been optimised over a period of many years by both engineers and tattooists For flawless handling and application please read the manual carefully before first using the ma chine Amongst other things you will be able to better understand the technical functions and usage scenarios of the Hawk spirit 1 General remarks Compared with conventional tattoo devices the Cheyenne is a lot quieter and doesn
21. oom whereby smoking is forbidden With regard to this please observe the local regulations on the layout and organisation of workplaces Warning Only dermatologically safe and those colours needed for the individual application purposes are to be used 95 6 6 1 Device set up The Hawk spirit is to be used indoors It can be operated without any problems in room temperatures ranging from 10 C to 35 C Before the start of operation it should be ensured that the device has adjusted to the room temperature as otherwise the condensate that is created could damage the elec tronics when there is a temperature difference of 10 C or more then please wait at least three hours 95 6 2 Device connection The Hawk spirit has been designed to fit connect to the Cheyenne Power Unit II PU II or with the use of the adapter that has been delivered with it to another direct current voltage source When using with the PU II please also make sure to read the manual of this device More details to the PU II can be found at the end of this manual If the Cheyenne PU is not used then the operating current should be between 6V and 12V One should make sure that the direct current voltage source has a performance value of at least 1 5A at 12V When connecting one should also ensure that the correct polarity is given When connecting to a laboratory power adapter in addition to the connecting cable 8 see construction design an add
22. rheitshinweise zum Nadelkopf Zur Entnahme des Nadelkopfes muss die Maschine abgeschaltet werden Beim Abschrauben des Nadelkopfes ist darauf zu achten dass eventuell vorhandene Farbreste nicht in die Maschine laufen Nach der Entnahme muss sichergestellt werden dass die Nadel komplett in den Kopf zur ckgezogen ist um Verletzungen vorzubeugen Auf den steril verpackten Nadelk pfen ist ein Etikett mit der Lotnummer Herstellungs und Ver fallsdatum angebracht Die Lotnummer dient zur eindeutigen Identifizierung der Charge und muss bei Problemen dem Hersteller mitgeteilt werden Unter den in Kapitel 13 angegeben Transport und Lagerbedingungen garantiert der Hersteller der Nadelk pfe die Sterilit t bei verschlossener und unbesch digter Verpackung f r 5 Jahre Die unbe nutzten Nadelk pfe m ssen in der 10 er Box aufbewahrt werden oo 6 6 Antrieb Die Maschine insbesondere der darin befindliche Antrieb 6 s Aufbauzeichnung ist ein mechani sches Pr zisionswerk das nicht verunreinigt werden darf Aus diesem Grunde darf keine Farbe in den Antrieb gelangen Der Nadelkopf 1 besitzt daf r ein R ckflusssicherungssystem was Eindrin gen der Farbe in die Maschine verhindert Sch den die auf das Eindringen von Farbstoffen in den Antrieb zur ckzuf hren sind werden vom Hersteller nicht als Reklamationsgrund anerkannt 10 MT DERM GmbH CHEYENNE 7 Wartung Sterilisation Zusammenbau Vor Beginn s mtlicher Reinigungs und
23. roval has to be given The procedure has to be immediately stopped if the patientis suffering from excessive pain e there is heavy loss of wound liquids e fainting spells dizziness occur 5 Important hygiene and safety instructions Before application the skin of the client is to be sterilised using a mild cleaning agent and disinfect ant Hereby the national guidelines for choosing the proper disinfectant have to be observed The operator has to protect him herself against possible infections by putting on disposable gloves One is not allowed to touch any unsterile or not disinfected objects with the gloves One should also avoid touching the freshly tattooed and still open skin This is both valid for disposable gloves as well as for all unsterile other utensils For every client and for every treatment only new and sterile needle heads are to be used and worked with They are only to be used once and should only be taken out of the sterile packaging before ap plication Here one should ensure that the packaging is not damaged or torn If the packaging is dam aged or torn the sterility of the needle heads is not guaranteed any more Needle heads are to be used before the expiry use by date and not any other ones When in use it should be ensured that the nee dle head is not touched at the front top In addition during the treatment and procedure one should make sure that the needle head does not by accident come into contact wit
24. stecker an den Minuspol des Ger tes anzu schlie en Der Adapter soll anschlie end mit dem Anschlusskabel 8 verbunden werden Achtung Die Maschine ist gegen Verpolung und berspannung gesichert so dass bei Verpo lung bzw Uberspannung Spannung ber 12V kein Betrieb der Maschine m glich ist Die Maschine bleibt au er Funktion Im Falle einer Verpolung des Anschlusses sind die Stecker am Netzger t umzustecken rot schwarz Im Falle einer Uberspannung muss die Spannung nach unten geregelt werden Danach ist die Maschine wieder betriebsbereit Ferner ist darauf zu achten dass das Kabel am Handst ck nicht geknickt wird Ein gefahrloser Betrieb ist nicht garantiert wenn das Ger t bzw das Zubeh r sichtbare Besch digungen aufweist wenn das Ger t nicht ordnungsgem arbeitet MT DERM GmbH CHEYENNE e nach l ngerer Lagerung au erhalb des vorgeschriebenen Temperaturbereiches bei Transportsch den nach unsachgem em Transport In diesen F llen sollte das Ger t grunds tzlich dem autorisierten Fachh ndler zur berpr fung ber geben werden 6 3 Nadelkopf Zur Verwendung des Nadelkopfes 1 s Abb 1 ist unbedingt Kapitel 5 wichtige Hygiene und Sicherheitshinweise zu beachten Abb 2 Einsetzen des Nadelkopfes Der Nadelkopf wird auf die Maschine aufgeschraubt W hrend des Aufschraubens des Nadelkopfes muss die Maschine unbedingt ausgeschaltet sein Es ist unmittelbar nach
25. tandards and to only work with sterile or disinfected work ing material Further information is listed in chapter 5 under the heading Important hygiene and safety instructions Please inform your clients about possible risks before starting any procedures Knowledge of the risks that are related to tattooing usually however with a very small chance of these occurring can be learned in training courses Here one can list the following risk of being scarred allergies and toxicological effects WWW CHEYENNE TATTOO COM 15 MEDIZINGER TE The manual must be read from front to back before starting with any operative use of machine The manufacturer does not assume any responsibilities or liabilities if this device is not used or oper ated for the explicitly stated purposes and the effects caused by this misuse non proper use oo 1 3 Technological advances The manufacturer would like to point out that the Cheyenne Hawk spirit is subject to alterations and modifications without prior notice at any time 95 2 Mode of operation When tattooing through the puncturing of the skin by the needle colour pigments are placed into the skin which are clearly visible and thereby lines as well as different shades are drawn The colour stays permanently within the skin Fading can possibly start after 3 to 5 years this is not always the case though The process depends very much on the colours used the ski
26. tshinweise Vor der Anwendung ist die Haut des Kunden mit einem milden Reinigungs und Desinfektionsmittel zu behandeln Dabei m ssen die nationalen Richtlinien bei der Auswahl der geeigneten Desinfekti onsmittel des jeweiligen Landes beachtet werden Der Anwender muss sich vor m glichen Infektionen durch Einmalhandschuhe sch tzen Es d rfen mit den Handschuhen keine unsterilen bzw nicht desinfizierten Gegenst nde angefasst werden Die Ber hrung der frisch t towierten und noch offenen Haut ist zu vermeiden Dies gilt sowohl f r die Einmalhandschuhe als auch f r alle nicht sterilen sonstigen Utensilien F r jeden Kunden und jede Behandlung sind ausschlie lich neue sterile Nadelk pfe zu verwenden Sie sind zum einmaligen Gebrauch bestimmt und erst unmittelbar vor der Anwendung aus der Steril verpackung zu entnehmen Hierbei ist darauf zu achten dass die Verpackung unbesch digt ist Bei besch digten Verpackungen ist die Sterilit t der Nadelk pfe nicht gew hrleistet Es sind nur Nadel k pfe vor Ablauf des Verfallsdatums zu verwenden Beim Einsetzen ist darauf zu achten dass der Nadelkopf nicht im vorderen Bereich angefasst wird Auch w hrend der Arbeit ist darauf zu achten dass der Nadelkopf nicht versehentlich mit kontaminierten Gegenst nden z B mit der Kleidung in Ber hrung kommt Falls das passieren sollte ist ein neuer steriler Nadelkopf zu verwenden Nach der Behandlung sind die Nadelk pfe in einer Safety Box als Klinik
27. unbedingt zu beachten Der Anwender ist verpflichtet die Grunds tze von Sauberkeit und Hygiene einzuhalten und nur mit sterilen bzw desinfizierten Ar beitsmaterialien zu arbeiten Weitere Informationen sind unter Kapitel 5 Wichtige Hygiene und Sicherheitshinweise aufgef hrt Informieren Sie die Kunden vor der Anwendung ber m gliche Risiken Wissen ber Risiken die mit der T towierung allerdings mit sehr geringer Auftrittswahrscheinlichkeit verkn pft sind wird in einer Schulung erlernt Hierzu z hlen unter anderem Risiken der Narbenbildung Allergien und toxikologische Wirkung WWW CHEYENNE TATTOO COM 5 MEDIZINGER TE Die Gebrauchsanweisung muss vor der Inbetriebnahme der Maschine komplett gelesen werden F r eine von dieser Gebrauchsanweisung abweichende Inbetriebnahme oder Verwendung des Ger tes und deren Folgen bernimmt der Hersteller keine Haftung oo 1 3 Technischer Fortschritt Der Hersteller beh lt sich nderungen im Sinne des technischen Fortschrittes vor oo 2 Wirkungsweise Beim T towieren werden durch die Einstiche der Nadel Farbpigmente sichtbar in die Haut eingetra gen und so Linien und Schattierungen gezeichnet Die Farbe verbleibt dauerhaft in der Haut Ein Verblassen beginnt evtl nach 3 bis 5 Jahren ist aber nicht immer gegeben Der Prozess ist abh ngig von der verwendeten Farbe dem Hauttyp der Sonnenbelastung der Tiefe der Pigmentierung und anderen Faktore
28. verwendet werden oo 6 Inbetriebnahme 6 1 Ger teaufstellung Die Hawk spirit ist f r die Verwendung in Innenr umen bestimmt Sie kann ohne Beeintr chtigung bei einer Raumtemperatur von 10 C bis 35 C betrieben werden Vor Inbetriebnahme des Ger tes muss darauf geachtet werden dass sich das Ger t an die Raumtemperatur angepasst hat da sonst das entstehende Kondensat die Elektronik besch digt bei 10 C Temperaturunterschied mindestens drei Stunden warten oo 6 2 Ger teanschluss Die Hawk spirit ist zum Anschluss die Cheyenne Power Unit II PU oder mittels des beilie genden Adapters an eine andere Gleichspannungsquelle konzipiert F r eine Verwendung mit der PU II beachten Sie bitte auch die Gebrauchsanweisung dieses Ger tes N here Hinweise zur PU II fin den Sie am Ende dieser Gebrauchsanweisung Wird nicht die Cheyenne PU II verwendet sollte die Betriebsspannung zwischen 6V und 12V liegen Es ist darauf zu achten dass die verwendete Gleichspannungsquelle eine Leistung von mindestens 1 5A bei 12V aufweist Beim Anschluss soll auf die richtige Polung geachtet werden F r ein An schlie en an ein Labornetzteil liegt zus tzlich zum Anschlusskabel 8 s Aufbauzeichnung ein Adapter nicht abgebildet im Lieferungsumfang bei Das Anschlusskabel 8 soll auf den Gleich stromanschluss 7 der Maschine aufgesteckt werden bis er einrastet Der rote Bananenstecker vom Adapter ist an den Pluspol und der schwarze Bananen
Download Pdf Manuals
Related Search
Related Contents
Comment consulter les archives Le Luberon: la fin d`un territoire d`exception? DeLOCK Adapter mini Displayport / VGA FM Netgear 7200 Series User's Manual Milltronics MUS - Lesman Instrument Company Comrac Deluxe arm, grommet fitting, black Manual do Usuario WD1855-WD1856 Page 1 Page 2 このたびは、 PR。VーDENCE/PEC Copyright © All rights reserved.