Home

TSI 8530-DPM PORTABLE DPM MONITOR

image

Contents

1. MENTS ti EE FA p J i i pe U ma Y i pe a J L m Y E lt p m With superior optics and particle detection system TSI s portable DPM monitors offer accuracy and resolution down to 1ug m3 versus 100ug m3 or worse on some competitive products That is a factor of 100 times better resolution compared to some competitive instruments TSl s 8530 DPM represents the very latest technology with all digital signal processing and a USB interface rather then the old RS232 interface still found on some competitive products The 8530 DPM also provides a multitude of popular latest generation communication options including Ethernet 4 20mA voltage outputs a relay contact closure amp USB for connection to almost any data logging SCADA or telemetry system The 8530 DPM represents rock solid and constantly evolving technology It is simply the smartest investment for any organisation undertaking portable diesel particulate measurements Another great feature of the 8530 DPM is the built in 60 000 point data logger which allows clients to log and later view or print out test results The 8530 DPM also features a large 5 7 touch screen graphical VGA color display variable flow rate up to 3 lpm for better particle transport up to 18 hour battery run time 2 internal batteries needed and many other popular enhancements Proper calibr
2. fitted on supply Sheath Air System Patended sheath air system and recessed optics to keep the optics clean during sampling Power Requirements Operates off either single re chargeable or dual re chargeable hot swappable batteries as well as 12 volts DC and ora 240v AC adapter supplied CE Rating Immunity EN61236 1 2006 Emissions EN61236 1 2006 Included Components 8530 DPM portable monitor 1 x 6600mA internal battery 240 volt battery charger Carry case Zero filter checker General accessories User manual amp calibration certificate Software amp PC interface cable Full 2 year warranty Options amp Accessories Spare internal battery SMS amp email messaging kit Web based data collection kit Internal shealth air filters Solar power system 20 per month web hosting of data Annual maintenance contract Annual clean amp calibration phTloy a 4 NATA Ww AOCREDITED FOR TECHNICAL COMPETENCE ace ta CEATIFIED GUALITY MEMEDCMADYT STEM ji t iti m Specifications are subject to change without notice Microsoft and Windows are trademarks of Microsoft Corporation Kenelec Scientific Pty Ltd VIC 23 Redland Dr Mitcham VIC 3132 T 1300 732 233 F 1300 732 244 NSW 8 L2 49 Frenchs Forest Rd Frenchs Forest NSW 2086 T 02 8977 4017 F 02 8977 4000 National Freecall No 1300 732 233 www kenelec com au
3. guidelines Uses the latest 90 degree light scattering technology 0 001 mg m3 high resolution measurements Built in pump 3 Ipm flow rate variable from 1 4 to 3 lpm 3 lpm flow rate provides better particle transport 60 000 point data storage once a minute for 45 days 5 7 inch real time VGA colour graphical touch screen display Fully menu driven and easy to use Excellent correlation with laboratory reference instruments Patented sheath air system amp recessed optics Made in the USA by world renowned TSI Incorporated Enhanced Features Include Both audible amp visual alarms to instantly alert users Provides 8 hour TWA data or data over any work shift Can be used as a highly accurate real time DPM monitor or highly accurate dust monitor 2 instruments for the price of one Includes 1um 2 5um 4um amp 10um impactors for PM fraction dust monitoring if switched to and used in dust monitor mode Easy zero check to validate field measurements Operates for up to 18 hours off 2 internal batteries Hot swappable batteries for no data loss during swap over 240 volt mains powered or powered from 12 volts DC Includes powerful Windows based analysis software Rugged construction for reliability in the field Field adjustable calibration factor adjustments capabilities Optional SMS amp Email messaging amp remote telemetry Service Support amp Calibration Fully serviced and supported in Australia by Kenelec Scientific Fully c
4. System Operates off 1 x 6600mA lithium ion battery for approximately 9 hours or 2 x 6600mA batteries hot swappable for 18 hours 4 hour per battery typical charge time Sampling Conditions May be used for normal ambient air DPM measurements up to typically 50 deg C Can be expanded adapted to make direct vehicle exhaust measurements TWA amp Shift Sampling Provides valuable data logging and 8 hour TWA measurements along with the ability to monitor over specific work shift periods Kenelec Scientific Measurement Device Primary Sensing Device TSI 8530 DPM new generation laser photometer with patented sheath air system and recessed optics Sensor Type 90 light scattering Particle Size Range Dust Mode 0 1um to 10 um Particle Size Range DPM Mode 0 1um to 1um Flow Rate 3 0 L min set at factory 1 40 to 3 0 L min user adjustable Flow Accuracy 5 of factory set point fully internal flow controlled Particle Concentration Range 0 001 to 400 mg m3 elemental carbon Measurement Resolution 0 1 of reading or 0 001 mg m3 whichever is greater Zero Stability 0 002 mg m3 per 24 hours at 10 sec time constant Temperature Coefficient 0 001 mg m3 per C Display 5 7 inch VGA colour touch screen Communications 1300 732 233 NATIONAL FREE CALL NUMBER USB 2 interface for PC connection and manual data download Data dump straight to any USB flash drive Field programmable fir
5. alibrated both optically and electronically to 1S012103 1 international standards by Kenelec Scientific Kenelec Scientific is Australia s leading NATA accredited and fully IS021501 compliant NATA calibration laboratory Lifetime FREE technical support rental options available Lifetime FREE firmware and software updates Kencl Scientific Modularity amp Expandability Use your 8530 DPM as a portable handheld meter to track down DPM sources and monitor background levels add an external data logger plug it into your existing SCADA system telemeter data back to base via the internet or other means Users can even buy an optional vehicle exhaust test kit where the 8530 DPM can be used to make direct vehicle exhaust diesel particulate measurements Smart Messaging amp Telemetry Options The 8530 DPM utilizing optional components is even capable of sending SMS and email messages to mobile devices and PC s via the internet on DPM alarm alerts It can also transmit valuable measurement data back to mobile devices and PCs via the internet for remote data storage and analysis Network connections include 3G NEXTG mobile underground mesh and others Constantly Evolving Technology Innovative design free updates numerous add ons plug ins and accessories available SPECIFICATIONS General Information Physical Case Rugged ABS plastic Dimensions 13 5 x 21 6 x 22 4cm Weight 2kg with 1 battery installed Internal Battery
6. ation of any optical electronic device of this type is absolutely paramount to ensure accurate reliable amp repeatable measurements Kenelec Scientific has decades of experience with optical electronic particle counting and sizing instruments With advanced service facilities and full NATA amp 18021501 accreditation in the calibration of optical particle counting sizing instruments no other company comes close to matching the experience and capabilities that Kenelec Scientific offers in Australasia Checking flow rates or using zero filters in the field is not enough In following global standards all instruments of this nature need to be calibrated on an annual basis in the laboratory by experienced optical electronic technicians Unlike some competitive companies that send equipment overseas for repairs or calibrations or do sub standard calibrations verifications in the field Kenelec Scientific sells services fully calibrates and supports all of our systems and instruments locally in Australia to the highest possible standards SMART DIESEL PARTICULATE MONITORING SOLUTIONS Designed for Portable Background Monitoring Standard Features Include 100nm to 1000nm particle size range 10um with inlet removed Real time on screen results to instantly inform users 37mm filter sample collection for NIOSH 5040 analysis 0 001 to 400mg m3 wide particle concentration range Fully compliant with both AIOH amp MDG29 Australian
7. mware updates all models Ethernet port for full remote control and access to data Outputs amp Alarms Internal audible amp visual alarms to warn users 0 to 5 VDC or 4 20mA outputs Fully user selectable scaling range Relay contact closure for local alarms standard Local warning lights and sirens available optional SMS messaging on alarms on SMS amp remote capable systems Telemetry amp Data Access Options Manual download using any USB flash drive 3G NEXTG mobile network data access capabilities Underground mesh network back to base capabilities SMS amp Email messaging with optional hardware update Full data access using internet amp web browser Internet data collection plans available from only 20 per month Primary Data Storage 5MB of onboard memory 60 000 data points providing logging once a minute for 45 days Secondary Data Storage Up to 64GB data storage for units fitted with companion data loggers for SMS and remote data access Logging Interval 1 second to 1 hour user adjustable Time Constant 1 second to 60 seconds Humidity Range 0 to 95 operational humidity range with the unit ideally not used in condensing environments Temperature Range 0 to 50 deg C operational temperature range and 20 to 60 deg C storage temperature range Size Selective Inlets All models come with 4 size selective inlets for PM1 PM2 5 PM4 and PM10 measurements PM1

Download Pdf Manuals

image

Related Search

Related Contents

User manual  WD TV Play Media Player User Manual  Bosch WZMB.001  TDS-3DK  GLOBALE Le nouvel événement culturel à l`ère du numérique  Win-Duo DM-985 User Manual  16697_MANUAL BETONEIRA MOB-400 G2_REVISAO 1  TFT LCD MONITOR USER MANUAL HSDE Series 10.4”,12.1”,15  Compte rendu de l`Assemblée Régionale extraordinaire du 21  Istruzioni per l`uso Periferiche  

Copyright © All rights reserved.
Failed to retrieve file