1. h the overhead lights manufacturer NOTE A LO BAT signal will be displayed if the battery needs to be changed Output measurements should be taken whenever there is a condition that may affect the phototherapy light output such as but not limited to 1 Before each patient use 2 Operating hours of Photobilirubin device 3 Cleanliness of device s optical system and 4 Condition of light emitting pad BATTERY INFORMATION The Joey Dosimeter operates with a single nine volt 9V nonrechargeable battery REPLACING THE BATTERY 1 Remove the battery compartment cover on the lower back side of the Joey Dosimeter 2 Lift out the 9 volt battery and replace it with a battery of the same type 3 Replace the battery compartment cover MAINTENANCE CLEANING Avoid getting fingerprints grease or dust on the sensor A dirty sensor will result in false low intensity readings Clean the sensor with a water dampened lens paper and then wipe dry DO NOT immerse in water or apply any water or commercial cleaning agents directly to the sensor and or digital display as this will cause damage to the device CAUTION We recommend that the display window only be wiped using a soft damp cloth while exerting very little pressure Rubbing your fingers across the display window creates static electricity which caused false readings BATTERY A weak battery will be shown automatically on the digital display LO BAT RECALIBRATION The Ph
2. iN RESPIRONICS THE JOEY DOSIMETER USER INSTUCTIONS DESCRIPTION The Joey Dosimeter is a wide band spectroradiometer used in neonatal phototherapy The response curve of the sensor is between 425nm 475nm with the peak at 450nm The meter measures irradiance in units of microwatts per centimeter per square nanometer uw cm nm The Joey Dosimeter should only be used to measure the irradiance of the wavelengths of blue light 425nm 475nm and for no other purpose A USE WITH FIBEROPTIC PHOTOTHERAPY DEVICES 1 Place photosensor face down on fiberoptic panel 2 Press the PUSH TO READ button 3 The Joey Dosimeter measuring device has one scale ranging from 00 0 to 99 0 uw cm nm 425 475 The light intensity uw cm nm can be read directly from the digital display B USE WITH OVERHEAD PHOTOTHERAPY DEVICES 1 Aim photosensor face towards the light source and press the PUSH TO READ button 2 Position the photosensor head close to the mid point of the infant s body and at the same level as the upper surface of the body To assure reproducible measurements the sensor head should be placed in the same relative position to the phototherapy light and the infant for each reading 3 The Joey Dosimeter measuring device has one scale ranging from 00 0 to 99 0 uw cm nm 425 475nm The light intensity uw cm nm can be read directly from the digital display NOTE For optimum placement of the Joey Dosimeter check wit
3. otobilirubin meter is calibrated against lamp standards traceable to the National Institute of Standards Technology It is calibrated to be 2 or one digit the least significant digit Proper calibration can only be accomplished with a National Institute of Standards traceable lamp standard It is recommended that the instrument be returned to Respironics Inc for recalibration immediately if the meter has been physically abused e g dropped jarred Otherwise the recommended time period for recalibration is ANNUALLY Send the Joey Dosimeter measuring device for recalibration to RESPIRONICS INC RESPIRONICS 1001 Murry Ridge Lane Deutschland Murrysville Pennsylvania Gewerbestrasse 17 15668 8550 USA 82211 Herrsching Germany WARRANTY RESPIRONICS INC WARRANTS THAT THE JOEY DOSIMETER WILL AT THE TIME OF SHIPMENT BE FREE AND CLEAR OF ALL LIENS AND ENCUMBRANCES AND WILL BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF PURCHASE FROM RESPIRONICS INC RESPIRONICS INC EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT WILL RESPIRONICS INC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES DUE TO BREACH OF THIS WARRANTY OR ANY OTHER OBLIGATION 577 0017 00 HM 12 16 02

Download Pdf Manuals

image

Related Search

Related Contents

NRB-2 NRB-4 - Pentair Nocchi  CASE STUDY5 もうけ話にご用心  Samsung NP-P428-DB01IN User Manual (FreeDos)  Samsung 7 Series NP730U3E  AirTies WUS-201  Yamaha DD45 drum  A1 User Manual - All Languages  TM889 USER'S MANUAL  REINER`S BÄHNLE - Reiners Bähnle  

Copyright © All rights reserved.
Failed to retrieve file