Home

2320 Rev C

image

Contents

1. readout rise and falltime transition time O level 100 level with markers at 10 and 90 Accuracy As oscilloscope Dual Input Meter The specified accuracy is valid over the temperature range 18 C to 28 C 64 F to 82 F Add 10 of specified accuracy for each C below 18 C or above 28 C 64 F to 82 F Max meter bandwidth 40 MHz Fluke 124 20 MHz Fluke 123 Voltage measurements Measurement selection Vdc Vac rms Vac dc rms Vpeak max Vpeak min Vpk px Ranges 500 mV 5 V 50 V 500 V 1250 V Full scale reading 5 000 counts Accuracy Vdc 0 5 5 counts Vac rms 1 Hz to 60 Hz 1 10 counts 60 Hz to 1 kHz 2 5 15 counts 20 kHz to 1 MHz 5 20 counts Vac dc true rms DC to 60 Hz 1 10 counts 60 Hz to 1 kHz 2 5 15 counts 20 kHz to 1 MHz 5 20 counts Vpeak Max peak or Min peak 5 of full scale Peak to peak 10 of full scale Ohms Ranges 500 Q 5 KQ 50 KQ 500 KQ 5 MQ 30 MQ Max resolution 5 000 counts Accuracy 0 6 of reading 5 counts Capacitance Ranges 50 nF to 500 pF Max resolution 5 000 counts Accuracy 2 of reading 10 counts Other meter functions Frequency Up to 70 MHz Fluke 124 or up to 40 MHz Fluke 123 Continuity Beeper on lt 30 Q Diode test Up to 2 8 V Amps Amp dc Amp ac Amp ac dc using an optional current clamp or shunt Scaling factors 0 1 mV Amp to 100 V Amp Temper
2. Real time clock Time and date stamp TrendPlot recording Power Line power Country specific line voltage adapter battery charger included Battery power Rechargeable Ni MH BP 130 installed in Fluke 124 or rechargeable NiCd BP 120 installed in Fluke 123 Battery operating time Up to 7 hours using BP130 up to 5 hours using BP120 Battery charging time 5 hours Fluke 123 7 hours Fluke 124 Battery power saving functions Auto power down with adjustable power down time On screen battery power indicator Accessories Standard Accessories Fluke 123 Fluke 124 Rechargeable battery pack installed Mechanical data Size 50 x 115 x 232 mm 2 x 4 5 x 9 1 in Weight 1 2 kg 2 64 lbs Safety Compliance EN61010 1 1993 Pollution degree 2 UL3111 1 1994 CAN CSA C22 2 No 1010 1 1992 ANSI ISA 82 01 1994 Input voltage ratings Maximum input voltage 600 V CAT III Maximum voltage between input and reference lead Maximum input voltage using VPS40 Probe 600 V CAT III 1000 V CAT II Maximum voltage between probe tip input and reference lead Floating voltage 600 V CAT III Maximum voltage between earth ground and any terminal signal input or reference lead Maximum voltage between reference leads Instrument has common grounds connected via self recovering fault protection For different ground potential measurements between inputs use DP 120 differential voltage probe Environmental Operati
3. V 10 A max AC80 Hook Style Test Clips for banana plugs red amp black 1000 V 3 A max AC83 Pin Grabber Test Clips for banana plugs red amp black 1000 V 1 A max AC85A Large Jaw Alligator Clips for banana plugs red amp black 600 V 10 A max AC120 Alligator Clips 120 red gray black For STL 120 and TL75 Test Leads 600 V 10 A max HC120 Hook Clips 120 red gray For STL 120 and TL75 Test Leads 600 V 3 A max Slim Reach Test Probes for banana plugs red amp black TP1 Flat blade for North American wall sockets TP2 2 mm diameter tip for electronics work TP4 4 mm diameter tip for European wall sockets TP38 With insulated tips TP74 Lantern tip banana style spring contacts with nickel plated brass ends Meet GS 38 safety Guidance Note issued by UK Ministry of Health and Safety TP80 Electronic Test Probe for banana plugs red amp black For electronic probing of high density boards Max Signal Voltage amp Voltage to Ground 600 V rms CAT III Rated for 10 A and 1000 V CAT III environments Page 5 of 6 Document 2321 ScopeMeter Accessories 2001 Fluke Corporation Rev A 9 2001 Safety Designed Cables and Adapters PAC91 Printer Adapter Cable 0 25 m Safety designed optical to parallel printer adapter cable See instrument Manual for compatible print
4. digits 80TK Thermocouple Module For Type K thermocouples with connector Range 50 C to 1000 C or 58 F to 1832 F Output 1 mV per C or F Accuracy 0 5 2 C or 0 5 3 6 F Optional probes for 80TK 80CK M Male Mini Connectors 80PK 1 K Type General Purpose Probe 80PK 2A K Type Immersion Probe 80PK 3A K Type Surface Probe 80PK 4A K Type Air Probe 80PK 5A K Type Piercing Probe 80PK 6A K Type Exposed Probe 80PK 7 K Type Industrial Surface Probe 80PK 8 K Type Pipe Clamp Probe Pressure Probes PV350 Digital Pressure Vacuum Module Measures pressure to 500 psi 3447 kPa and vacuum from O to 76 cm Hg 0 to 29 9 Hg All ratings per IEC 1010 2 032 Pollution Degree 2 Fluke Keeping your world up and running Fluke Corporation PO Box 9090 Everett WA USA 98206 Fluke Europe B V PO Box 1186 5602 BD Eindhoven The Netherlands For more information call In the U S A 800 443 5853 or Fax 425 446 5116 In Europe M East Africa 31 40 2 675 200 or Fax 31 40 2 675 222 In Canada 800 36 FLUKE or Fax 905 890 6866 From other countries 425 446 5500 or Fax 425 446 5116 Web access http www fluke com
5. external trigger All inputs isolated from each other and ground Input coupling AC or DC with ground level indicator Input sensitivity 2 mV div to 100 V div Fluke 190C Series 5 mV div to 100 V div Fluke 190B Series Variable attenuator Variable gain on input channel A Input voltage 1000 V CAT II 600 V CAT III rated See general specifications for further details Vertical resolution 8 bit Accuracy 1 5 of reading 0 04 x range div Input impedance 1 MQ 1 15 pF 2 pF Horizontal Maximum real time sample rate Number of 2 2 2 digitizers Time base range Fluke 199C Fluke 199B 2 5 GS s Fluke 196C Fluke 196B Fluke 192B 500 MS s 5 ns div to 5 s div 10 ns div to 5 s div Maximum record length 1 200 points per input in Scope mode 27 500 points per input in ScopeRecord roll mode 5 ms div to 2 min div Accuracy 0 01 of reading 1 pixel Glitch capture 50 nsec at 5 usec div to 1 min div 250 nsec at 2 min div Display and Acquisition 144 mm 5 67 monochrome LCD Input A input B dual average invert replay persistence on off 144 mm 5 67 full color LCD Input input B dual average invert replay Digital Persistence mode short medium long infinite Display Display modes Visible screen width 12 divisions in scope mode Waveform mathematics A B A B A B all with user selectable scaling of resul
6. memory locations that each can contain two waveforms plus corresponding setup Recorder memories 2 memory locations that each can contain 100 captured dual input scope screens or a dual input ScopeRecord 27 500 Min Max pairs per input or a dual input Trendplot 18 000 min max pairs average values Real Time Clock Time and date stamp for ScopeRecord 100 captured screens and TrendPlots Power Line power Country specific line voltage adapter battery charger included Battery power Rechargeable NiMH installed Battery operating time 4 hours Battery charging time 4 hours Battery power saving functions Auto power down with adjustable power down time On screen battery power indicator Mechanical Data Size 256 x 169 x 64 mm 10 1 x 6 6 x 2 5 in Weight 2 kg 4 4 lbs Accessories Rechargeable battery pack installed Safety Compliance EN61010 1 1993 Pollution degree 2 UL 3111 1 1994 CAN CSA C22 2 No 1010 1 1992 ANSI ISA 82 01 1994 Input Voltage Ratings Maximum probe voltage 1 000 V CAT II 600 V CAT III Maximum voltage between 10 1 probe tip VPS200 and reference lead Floating voltage 1 000 V CAT II 600 V CAT III Maximum voltage between earth ground and any terminal signal input or shielding Independently isolated inputs 1 000 V CAT 11 600 V CAT Ill Maximum voltage between any terminal of one input or probe VPS200 and any other terminal of another input or probe VPS2
7. 0 1 10 A 100 mV A 1 1 5 Hz 100 kHz 0 1 100 A 10 mV A 1 1000 A 1 mV A i2000flex 2 200A 10 mV A 1 FS 1 Hz 20 kHz 20 2000 A 1 mV A i3000s 1A 30 10 mV A 2 2 A 10 Hz 100 kHz 1A 300A 1 mV A 1A 3000 A 0 1 mV A AC DC Current Clamps Type Ranges Basic Accuracy reading Usable Frequency Range Ps 80i 110s A N 0 1 10 A AC DC 100 mV A 3 50 mA DC 100 kHz P 1 100 A AC DC 10 mV A 10A A 4 Ny 600 V CAT II j 300 V CAT III rated WY i410 1 A 400 A AC DC 1 mV A 3 5 0 5 A DC 3 kHz 11010 1 A 600 A AC 1 mV A 2 0 5 A DC 10 kHz 1 A 1000 A DC 1 mV A CS20MA 4 20 mA shunt 0 1 DC 10 kHz 10 Q 10 mV mA 30 V CAT III rated 600 V CAT III rated FLUKE Page 4 of 6 Document 2321 ScopeMeter Accessories 2001 Fluke Corporation Rev A 9 2001 Industrial Test Leads and Accessories STL120 1 2 m Industrial Shielded Test Lead Set 12 5 MHz for ScopeMeter 120 Series red gray Compatible with AC120 amp HC120 Maximum current 1A TL20 1 6 m Industrial Silicone Test Lead Set Incl Test Probes and Alligator Clips for banana plugs red and black TL24 1 6 m Silicone Test Leads red and black TL75 1 2 m Hard Point Right Angle Test Lead Set red amp black Compatible with AC120 amp HC120 AC20 Industrial Alligator Clips for banana plugs red amp black 1000
8. 00 Maximum voltage on BNC input directly input A or B 300 V CAT III Maximum voltage on meter input 1 000 V CAT II 600 V CAT III Environmental Operating temperature O C to 50 C Storage temperature 20 C to 60 C Humidity 10 C to 30 C 95 RH non condensing 30 C to 40 C 75 RH non condensing 40 C to 50 C 45 RH non condensing Maximum operating altitude 3 000 m 10 000 feet Maximum storage altitude 12 km 40 000 feet Electro Magnetic Compatibility EMC EN 61326 1 for emission and immunity Optically Isolated PC Printer Interface PC communication Transfer instrument settings screen images waveform data and waveform references compatible with FlukeView software for Windows via optional PM9080 To printer Supports HP Laserjet DeskJet Epson FX LQ and Postscript printers via optional PAC 91 Warranty 3 years parts and labor on mainframe instrument 1 year on accessories Standard Accessories Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B BP190 Line voltage adapter Battery charger BC190 Voltage probes and accessories 10 1 voltage probe VPS200 1 red 1 grey including hook clip ground lead with mini alligator clip ground lead with hook clip 4 mm add on probe tip ground lead to 4 mm banana plug Multimeter test leads TL75 Hard Point test lead set lred 1 black User manual 9 language versions on CD ROM Getting Starte
9. CAT III 1000V CAT II rated 200 1 20 1 1200 Vp 120 Vp 20 MHz 20 MHz ITP120 Optically isolated trigger probes 1 2 m for ScopeMeter 123 Incl Hookclip with ground lead Max signal voltage amp voltage to ground 600 V rms CAT II Safety Designed Oscilloscope Probe Accessories For VPS Series probes AS200 G Probe Accessory Set Gray AS200 R Probe Accessory Set Red Set includes 600 V CAT III 1000 V CAT II rated Industrial Alligator for Probe 2 mm Test Probe for Probe 2 mm Test Probe for Banana Industrial Alligator for Banana Ground Lead 4 mm Banana RS200 Probe Replacement Set Set includes 600 V CAT III 1000 V CAT II rated Hook Clip for Probe Tip 2 red 1 gray 4 mm Test Probe for Probe 1 red 1 gray Ground Lead with Hook Clip 1 red 1 gray Ground Lead with Mini Alligator 2 black 30 V CAT II rated Ground Spring for Probe Tip 5x PM9090 Pin grabber red and gray Maximum Voltage 600 V rms CAT III Page 3 of 6 Document 2321 ScopeMeter Accessories 2001 Fluke Corporation Rev A 9 2001 FLUKE o AC Current Clamps Range Basic Accuracy reading Usable Frequency Range i200s 0 1 20 A 100 mV A 1 5 0 5 A 40 Hz 10 kHz 0 5 200 A 10 mV A 80i 500s 1 500 A 1 mV A 2 5 Hz 10 kHz i1000s
10. Fluke Corporation Rev C 12 2002 International Safety Standards Overvoltage Category Summary description CAT IV Three phase at utility connection any outdoors conductors under 1 000 V e Outside and service entrance e Service drop from pole to building Run between meter and panel Overhead line to detached building Underground line to well pump Three phase distribution under 1 000 V including single phase commercial lighting and distribution panels Feeders and short branch circuits e Distribution panel devices Heavy appliance outlets with short connections to service entrance Single phase receptable connected loads Outlets and long branch circuits All outlets at more than 10 m 30 ft from Category III source All outlets at more than 20 m 60 ft from Category IV source Electronic Electronic equipment Low energy equipment with transient limiting protection CAT III CAT II CAT I To protect your instrument and more importantly yourself choose a test tool that can withstand the electrical hazards present in the environment in which you plan to use it EN61010 establishes international safety require ments for electrical measurement equipment It separates the various electrical environments into installation categories based on the danger from high FlukeView ScopeMeter FlukeView software adds PC power to your Fluke ScopeMeter Test T
11. Page 1 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002 Fluke Corporation Rev C 12 2002 ScopeMeter 190C 190B Series and ScopeMeter 120 Series ScopeMeter 190C and 190B Series Speed performance and analysis power For demanding applications the ScopeMeter 190C and 190B Series high performance oscilloscopes offer specifications usually found on top end bench instruments With up to 200 MHz bandwidth 2 5 GS s real time sampling and a deep memory of 27 500 points per input they re ideal for engineers who need the full capabilities of a high performance scope in a hand held battery powered instrument Connect IeW Dual input 200 100 or 60 MHz bandwidth Up to 2 5 GS s real time sampling per input Connect and View automatic triggering a full range of man ual trigger modes plus external triggering Digital Persistence for analyzing complex dynamic signals like on an analog oscilloscope 190C Fast display update rate for seeing dynamic behavior instantaneously Automatic capture and replay of 100 screens FLUKE Technical Data 27 500 points and more per input record length using ScopeRecord mode TrendPlot paperless recorder for trend analysis up to 22 days 1 000 V CAT II and 600 V CAT III safety certified Waveform reference for visual comparison and automatic pass fail testing 190C of waveforms Up to 1 000 V independently floating isolated in
12. VPS40 40 MHz 10 1 Voltage probe set for use Fax 425 446 5116 Fluke 120 Series with Fluke 120 Series Web access http www fluke com Page 1 of 6 Document 2321 ScopeMeter Accessories 2001 Fluke Corporation Rev A 9 2001 ScopeMeter Accessories PC Software SW9OW FlukeView ScopeMeter Software for Windows For Fluke 190 amp 120 Series ScopeMeter Windows 95 98 NT 4 0 2000 e Requires one free RS 232 port COM port Optional PM9080 RS 232 Adapter Cable required SCC120 Software Cable Case 120 Series SCC190 Software Cable Case 190 Series Accessories Package including e FlukeView ScopeMeter Software for Windows English French and German languages PM9080 Optically Isolated RS 232 Adapter Cable e Hard Carrying Case C120 or C190 C120 Hard Carrying Case for 120 Series C190 Hard Carrying Case for 190 Series Storage compartments for test leads probes instruction manual power adapter and other small accessories C195 Soft Carrying Case Universal Durable soft case Adjustable storage compartments suitable for all ScopeMeter models Storage compartments for test leads probes instruction manual power adapter and other accessories C125 Compact Soft Case 120 Series Zippered carrying case black for 120 Series Pouch is designed to carry test leads and probes Convenient belt l
13. Waveform compare Max record length in Scope Mode in ScopeRecord mode Number of inputs Number of digitizers Independently floating isolated inputs Input sensitivity 512 min max points per input 2 2 1200 points per input channel 27 500 points per input or more 5 ms div to 2 min div 2 plus external DMM input all isolated from each other and from ground 2 Up to 1000 V between inputs references and ground 2 mV div to 100 V div 5 mV div to 100 V div 5 mV div to 500 V div Glitch capture Up to 3 ns using pulse width triggering 50 ns peak detect at 5 ms div to 1 min div 40 ns Timebase range in Scope mode 5 ns div to 2 min div 10 ns div to 10 ns divto 20 ns div to 2 min div 1 min div 1 min div Trigger types Connect and View Free Run Single Shot Edge Delay Video Frame Connect and View Free Run Video Line Selectable Pulse Width and External Single Shot Edge Video Scope measurements 7 cursor measurements 30 automatic measurements cursors 26 26 automatic automatic measurements measurements Waveform mathematics A B A B A x B A versus B X Y mode giving Lissajous diagrams ScopeRecord trigger modes Start on trigger stop on trigger Capture last 100 screens Automatic with replay capability Dual input TrendPlot Yes with cursors and zoom Yes Memory for screens and 10 screens with set up set ups 5 more memories are made available upon
14. ature C F With optional accessories Scale factors 1 mV C or 1 mV F Number of inputs 2 Input impedance 1 MQ 1 10 pF 2 pF Advanced meter functions Auto manual ranging TouchHold Relative measurements zero reference TrendPlot recording Page 6 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002 Fluke Corporation Rev C 12 2002 Recorder Mode Trendplot recording Dual input electronic paperless chart recorder Plots and displays the actual minimum maximum and average of any measurement Source and display Input A Input A and B Range 15 s div to 2 days per division automatic Recorded timespan Up to 16 days with a resolution of 1 5 hours Recording mode Continuous with automatic vertical scaling and horizontal time compression Measurement speed 2 5 measurements per second maximum Horizontal scale Time from start General Specifications Case Design Rugged shock proof with integrated protective holster Drip and dust proof IP51 according to IEC529 Shock and vibration Shock 30 g Vibration 3 g sinusoidal according to MIL PRF 28800F Class 2 Display Bright LCD with CCFL backlight 60 35 cd m2 with without power adapter Size 72 x 72 mm 2 8 x 2 8 inch Resolution 240 x 240 pixels Contrast and brightness User adjustable temperature compensated Memory Save and Recall 20 10 in Fluke 123 instrument screens with user set ups and user text
15. ccuracy 0 1 of reading 1 pixel Glitch detect 40 ns Display and acquisition Display modes Input A input A and B envelope smooth Acquisition modes Normal including glitch capture single shot roll Trigger and delay Source Input A input B external via optional ITP120 Modes Automatic Connect and View Free Run Edge Single Shot Video Video Line Connect and View Advanced automatic triggering that recognizes signal patterns and automatically sets up and continuously adjusts triggering time base and amplitude Automatically displays stable pictures of complex and dynamic signals like motor drive and control signals Video triggering NTSC PAL PAL SECAM Includes line select Time delay Up to 10 divisions pre trigger view Measurements Vdc Vac Vac dc Vpeak max Vpeak min Vpeak to peak frequency Hz positive pulse width negative pulse width positive duty cycle negative duty cycle Amp ac Amp dc Amp ac dc Phase Temperature C Temperature F dBV dBm into 50 Q and 600 Q Amps C or F with optional probes Cursor Measurements 124 only Sources Input A Input B Modes Single or dual vertical cursor dual horizontal cursor rise or falltime Measurements Single vertical line Average min value max value time from start of recording in roll mode Dual vertical lines AV at markers time between cursors 1 T between cursors in Hz Dual horizontal lines High low or AV
16. ce and instructions e Capture complete Replay sequence into the PC for further analysis and documentation e English French and German versions included on a single CD ROM Note Some functionality may be available with specific ScopeMeter models only System requirements e Pentium 90 or better e CD ROM drive e Windows 95 98 Me NT 4 0 2000 XP e One free RS 232 port e PM9080 Optically isolated RS 232 adapter cable available separately or included in SCC190 SCC120 kit and in ScopeMeter S versions Supported Instruments Full support for Fluke 199C 199B 199 196C 196B 196 192B 192 124 123 FLUKE FLUKE Page 8 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002 Fluke Corporation Rev C 12 2002 Selection Guide 190C Color ScopeMeter Series 190B ScopeMeter Series Fluke 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 124 Fluke 123 Bandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHz Max real time sample rate 2 5 GS s 1 GS s 2 5 GS s 1 GS s 500 MS s 25 MS s Max equivalent time sanble nite 2 5 GS s 1 25 GS s 144 mm full color LCD 144 mm monochrome LCD 102 mm monochrome LCD Yes gives analog oscilloscope like waveform decay user selectable Yes Visual reference and automatic Pass Fail testing Display Digital persistence Yes Yes Visual reference Envelope mode
17. d booklet included with instrument Page 5 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002 Fluke Corporation Rev C 12 2002 FLUKE Technical Specifications ScopeMeter 120 Series Oscilloscope Mode Vertical deflection Bandwidth and Risetime Fluke 124 Fluke 123 Bandwidth risetime e with VPS40 probes 40 MHz 20 MHz e input A and B directly 40 MHz 20 MHz e with STL120 Shielded Test Leads 12 5 MHz 12 5 MHz Instrument risetime input directly 8 75 ns 17 5 ns Number of inputs 2 Input coupling AC DC with ground level indicator Input sensitivity 5 mV to 500 V div with the included VPS40 Fluke 124 and STL120 shielded test leads measure up to 600 Vrms CAT III Input voltage 600 V CAT III See General Specifica tions for more detailed information Vertical resolution 8 bit Accuracy 2 of reading 0 05 x range div Input impedance 1 MQ 1 225 pF with STL120 shielded test leads 1 MQ 1 20 pF 3 pF with BB120 5 MQ 1 15 5 pF with VPS40 10 1 Volt age probe Horizontal Max sample rate both channels simultaneously Fluke 124 2 5 GS s for repetitive signals 25 MS s for single shot Fluke 123 1 25 GS s for repetitive signals 25 MS s for single shot Number of digitizers 2 Time base range 10 ns div to 1 min div Fluke 124 20 ns div to 1 min div Fluke 123 Maximum record length 512 Min Max points per input A
18. ers FLUKE PM9080 Optically isolated RS 232 Interface Adapter PM9081 Dual banana plug 4 mm male to female BNC Adapter The set consists of two adapters PM9082 Dual banana jack 4 mm female to male BNC Adapter The set consists of two adapters PM9091 50 Ohm Coaxial BNC cable set 3 x 1 5 m Three colored BNC male connectors red gray and black for easy identification PM9092 50 Ohm Coaxial BNC cable set 3 x 0 5 m Three colored BNC male connectors red gray and black for easy identification PM9093 Male BNC to dual female BNC T piece Set consists of two adapters BB120 Two shielded Banana to BNC Adapters Adapting Probes and BNC adapters to 120 Series ScopeMeters Max Signal Voltage 300 V rms CAT III Max Voltage to Ground 600 V rms CAT III Page 6 of 6 Document 2321 ScopeMeter Accessories 2001 Fluke Corporation Rev A 9 2001 Temperature Probes 80T 150U Universal Temperature Probe For air surface and non corrosive liquids Range 50 C to 150 C or 58 F to 320 F Output 1 mV per C or F Accuracy 1 C 1 8 F O C to 100 C FLUKE o 80T IR Non Contact Infrared Temperature Probe For hazardous to touch moving easily contaminated or difficult to reach surfaces Range 18 C to 260 C or O F to 500 F Output 1 mV per C or F Accuracy 3 of reading 3
19. g Fluke 196C Color ScopeMeter 100 MHz 1 GS s Windows Fluke 199B S ScopeMeter 200 MHz 2 5 GS s with PM9080 Optically isolated RS232 adapter cable SCC190 kit SCC190 Software Cable Case kit for Fluke Fluke Corporation Fluke 199B ScopeMeter 200 MHz 2 5 GS s 190 Series PO Box 9090 Everett WA USA 98206 Fluke 196B S ScopeMeter 100 MHz 1 GS s with SCC120 Software Cable Case kit for Fluke SCC190 kit 120 Series Fluke Europe B V Fluke 196B ScopeMeter 100 MHz 1 GS s C195 Durable universal soft carrying case for PO Box 1186 5602 BD Fluke 192B S ScopeMeter 60 MHz 800 MS s with ScopeMeters and accessories Eindhoven The Netherlands SCC190 kit C190 Hard shell protective carrying case for For more information call Fluke 192B ScopeMeter 60 MHz 500 MS s Fluke 190 Series ScopeMeters In the U S A 800 443 5853 or Fluke 124 S Industrial ScopeMeter 40 MHz with C125 Durable protective soft carrying case for Fax 425 446 5116 SCC120 kit Fluke 120 Series ScopeMeters In Europe M East Africa 31 0 40 2675 200 or Fluke 124 Industrial ScopeMeter 40 MHz C120 Hard shell protective carrying case for Fax 31 0 40 2675 222 Fluke 123 S Industrial ScopeMeter 20 MHz with Fluke 120 Series ScopeMeters In Canada 800 36 FLUKE or SCC120 kit DP 120 Differential Voltage Probe for use with Fax 905 890 6866 Fluke 123 Industrial ScopeMeter 20 MHz Fluke 120 Series From other countries 425 446 5500 or BP120 Rechargeable NiCd Battery for use with
20. iv to 48 hr div in view all mode giving overview of total record Recorded timespan Up to 22 days with a resolution of 1 minute Recording mode Continuous roll for the duration of the full recordable timespan Measurement speed 5 measurements per second Horizontal scale Time from start time of day Zoom Up to 64x zoom Memory Up to 2 TrendPlot recordings can be saved for later recall and analysis Cursor measurements all recorder modes Source Input A B or DMM input Dual vertical lines Min Max or Average voltage Time between cursors Single vertical line Min Max or Average voltage Absolute date and time or time from start Page 4 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002 Fluke Corporation Rev C 12 2002 General Specifications Case Design Rugged shock proof with integrated protective holster Drip and dust proof IP51 according to IEC529 Shock and Vibration Shock 30 g Vibration sinusoidal and random 3 g according to MIL PRF 28800F Class 2 Fluke 199C 196C Bright full color LCD with CCFL backlight Fluke 199B 196B 192B Bright monochrome LCD with CCFL backlight 125 75 Cd m with without power adapter Display 80 30 Cd m with without power adapter Display size 115 2 x 86 4 mm 4 54 x 3 4 in Resolution 320 x 240 pixels Contrast and brightness User adjustable temperature compensated Memory Save and Recall Scope memories 10
21. ng temperature O C to 50 C Storage temperature 20 C to 60 C Humidity 10 C to 30 C 95 RH non condensing 30 C to 40 C 75 RH non condensing 40 C to 50 C 45 RH non condensing Maximum operating altitude 2 000 m 6 500 feet 3 000 m 10 000 feet voltages lt 400 V Maximum storage altitude 12 km 40 000 feet Electro Magnetic Compatibility Emission EN50081 1 EN55022 and EN60555 2 Immunity EN50082 2 IEC 1000 4 2 3 4 5 Optically isolated PC Printer interface To printer Supports HP Laserjet Deskjet Epson FX LQ and postscript printers via optional PAC91 To PC Transfer instrument settings screen images and data compatible with FlukeView software for Windows via optional PM9080 Warranty 3 years parts and labor on mainframe instrument 1 year on accessories BP120 Fluke 123 BP130 Fluke 124 Line voltage adapter Battery charger PM8907 STL120 Shielded Test lead set VPS40 high impedance 10 1 probe 40 MHz 1 black included with Fluke 124 only HC120 hook clips ground leads with mini alligator clips AC120 alligator clips BB120 BNC to Shielded banana adapter TL75 Hard Point test lead 1 black 14 language versions on CD ROM Getting Started booklet included with instrument Voltage probes and accessories Multimeter test leads User manual Page 7 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002
22. ools FlukeView ScopeMeter software helps you get more out of your ScopeMeter e Store instrument s screen copies on the PC in color with Fluke 190C Series or in black and white Fluke 190B and 120 Series e Copy color screen images into your reports and documentation color screen images with Fluke 190C Series only e Capture and store waveform data from your ScopeMeter on your PC e Create and archive waveform references for auto matic Fluke 190C Series or visual Fluke 190B and 190C Series comparison e Use cursors for parameter measurement e Includes waveform analysis e g FFT spectrum analysis e Copy waveform data into your spreadsheet for detailed analysis e Extended recording of up to four user selected measurements help you monitor and analyze slow moving signals and related events e Logging of other readings directly into other appli cation programs eg spreadsheet voltage energy transients To choose the right tool the voltage rating alone does not determine the safety It is the combination of voltage rating and installation category that determines maximum tran sient withstand capability of the tool CAT III rated instruments are recommended for measurement on industrial power distribution systems Software for Windows e Add user text to instrument setups and send these to the instrument for operator referen
23. oop accommodates tool belt Powering and Charging pi PM8907 Line Voltage Adapter Battery Charger 120 Series SS gt BC190 Line Voltage Adapter Battery Charger 190 Series P 801 Europe 230 V 10 803 North America 120 V 10 a 804 United Kingdom 230 V 10 806 Japan 100 V 10 Qi 807 Australia 230 V 10 w 808 Universal switchable 115 V 15 or 230 V 15 Page 2 of 6 Document 2321 ScopeMeter Accessories 2001 Fluke Corporation Rev A 9 2001 Safety Designed Oscilloscope Probes Double insulated GOOV CAT III 1000V CAT II rated FLUKE Type Description Attenuation Max Signal Voltage Band Width VPS200 G DO Voltage Probe Set 10 1 1000 V 200 MHz one gray VPS200 R DO Voltage Probe Set 10 1 1000 V 200 MHz one red c us LISTED VPS201 O 100 1 Voltage Probe Set 100 1 1000 V 200 MHz red and gray VPS250 P 2 5 m Voltage Probe Set 10 1 1000 V 75 MHz as red and gray n eo VPS121 c UL us 1 1 Voltage Probe Set 1 1 300 V 12 MHz LISTED probe one black Probe sets include 600 V CAT III 1000 V CAT II rated Voltage Probe 1 2 m Hook Clip for Probe Tip 4 mm Test Probe for Probe Ground Lead with Hook Clip Ground Lead with Mini Alligator 30 V CAT II rated Ground Spring for Probe Tip DP120 Differential probe 1 5 m with shrouded banana probe tips red and black 600V
24. puts Four hours rechargeable NiMH battery pack ScopeMeter 120 Series Three in one simplicity The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and installation applications It s a truly integrated test tool with oscilloscope multi meter and paperless recorder in one affordable easy to use instru ment Find fast answers to problems in machinery instrumentation control and power systems e A dual input 40 MHz or 20 MHz digital oscilloscope e Two 5 000 counts true rms digital multimeters e Cursor measurements Fluke 124 e A dual input TrendPlot recorder e Connect and View trigger simplicity for hands off operation e Shielded test leads for oscillo scope resistance continuity and capacitance measurements e Full bandwidth VPS40 10 1 40 MHz probe included standard with Fluke 124 e Up to seven hours battery operation 600 V CAT III safety certified Optically isolated RS 232 interface e Rugged compact case Page 2 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002 Fluke Corporation Rev C 12 2002 Technical Specifications 190C and 190B Series Oscilloscope Mode Vertical Deflection Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Bandwidth 200 MHz 100 MHz 60 MHz Rise time 1 7 ns 3 5 ns 5 8 ns Bandwidth limiter User selectable 10 kHz 20 MHz or off Number of inputs 2 plus
25. registration of the ScopeMeter 20 10 Two each can store 100 scope screens a ScopeRecord or a TrendPlot 5000 counts Volts Amps Ohms Continuity Diode Temp 1000 V CAT II 600 V CAT III instrument and included accessories 600 V CAT III instrument and included accessories 7 hr NiMH 5 hr NiCd Memory for recordings True rms multimeter Safety certified EN61010 1 Battery installed 4 hr Ni MH BP190 Line Power Adapter battery charger included Size 25 x 16 9 x 6 4 cm 10 1 x 6 7 x 2 5 in 232 x 115 x 50 mm 9 2 x 4 5 x 2 in Weight 2 kg 4 4 1b 1 2 kg 2 64 lbs PC and Printer Interface Using optional optically isolated RS 232 adapter cable Warranty 3 years on main instrument 1 year on the standard accessories Detailed technical specifications and optional accessories can be found on the Fluke web site There you can also download a fully functional instrument which is based on the real instrument firmware Check it out at www fluke com scopemeter gdel Tglele Risiiolgest tilele Fluke 199C S Color ScopeMeter 200 MHz 2 5 GS s BP130 Rechargeable NiMH Battery for use with with SCC190 kit Fluke 120 Series Fluke 199C Color ScopeMeter 200 MHz 2 5 GS s BP190 Rechargeable NiMH Battery for use with Fluke 196C S Color ScopeMeter 100 MHz 1 GS s Fluke 190 Series ScopeMeters Fluke Keeping your world with SCC190 kit SW90W FlukeView ScopeMeter Software for up and runnin
26. rives and frequency inverters Cursor Measurements Source Input A input B or the Mathematical Result trace Dual horizontal lines Voltage at cursor 1 and 2 voltage between cursors Dual vertical lines Time between cursors 1 T between cursors in Hz voltage between markers risetime with markers falltime with markers Single vertical line Min Max and Average voltage at cursor position Zoom Up to 8x horizontal zoom Page 3 of 8 Document 2320 ScopeMeter 190C 190B Series and ScopeMeter 120 Series 2002 Fluke Corporation Rev C 12 2002 Meter Mode Via 4 mm banana inputs Fully isolated from scope inputs and scope ground The specified accuracy is valid over the temperature range 18 C to 28 C 65 F to 82 F Add 10 of specified accuracy for each degree C below 18 C or above 28 C Maximum Resolution 5 000 counts Voltmeter Ranges 500 mV 5 V 50 V 500 V 1 000 V Accuracy Vdc 0 5 5 counts Vac true rms 15 Hz 60 Hz 1 10 counts 60 Hz 1 kHz 2 5 15 counts Vac dc true rms dc 60 Hz 1 10 counts 60 Hz 1 kHz 2 5 15 counts Ohms Ranges 500 Q 5 KQ 50 KQ 500 KQ 5 MQ 30 MQ Accuracy 0 6 5 counts Other Meter Functions Continuity Beeper on lt 50 Q 30 Q Diode test Up to 2 8 V Amps Adc Aac Aac dc using an optional current clamp or shunt Scaling factors 0 1 mV A 100 V A Temperature C F With optional accessories Scale fac
27. tant A versus B X Y mode Acquisition modes Normal auto single shot ScopeRecord roll glitch capture waveform compare waveform compare with automatic Pass Fail testing in 199C and 196C only Trigger and Delay Source Input A input B external trigger input All input references isolated from each other and from ground Modes Automatic Connect and View free run single shot edge delay video video line selectable pulsewidth Connect and View Advanced automatic triggering that recognizes signal patterns automatically sets up and continuously adjusts triggering time base and amplitude Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals Video triggering NTSC PAL PAL SECAM Includes field 1 field 2 and line select Pulse width triggering Pulse width qualified by time Allows for triggering lt t gt t t t where t is selec table in minimal steps of 0 01 div or 50 nsec Time delay One full screen of pre trigger view or up to 100 screens 1200 divisions of post trigger delay Automatic Capture of 100 Screens The instrument ALWAYS memorizes last 100 screens no user interaction or setup required When an anomaly occurs on screen the HOLD button can be pressed to review the full screen sequence over and over Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in paby sit mode and
28. tors 1 mV C or 1 mV F Input impedance 1 MQ 1 10 pF 2 pF Advanced meter functions Auto manual ranging relative measurements Zero reference TrendPlot recording FLUKE Recorder Mode ScopeRecord Roll Mode Dual input waveform storage mode Source and display Input A Input B Dual Memory depth 27 500 points per input or more Each point consists of Min Max pair Min Max values Min Max values are measured at high sample rates ensuring capture and display of glitches 5 ms div to 1 mia Recorded timespan 6 sec to 24 hr Glitch capture 50 ns Sample rate 20 MS s Resolution 200 jisec to 2 sec 250 ns 4 MS s 4 8 sec Recording modes Single sweep continuous roll Start on Trigger Stop on Trigger Stop on Trigger through external ScopeRecord mode can be stopped by an individual trigger event or by an interruption of a repetitive trigger signal Horizontal scale Time from start time of day Zoom Up to 100x Memory Up to 2 dual input ScopeRecord waveforms can be saved for later recall and analysis TrendPlot recording Single or dual input electronic paperless chart recorder Plots displays and stores meter and scope measurements Source and display Input A Input B or DMM input Memory depth 18 000 points recording Per record point a minimum a maximum and an average value plus a date and timestamp are recorded Ranges 5 s div to 30 min div in normal view mode 5 min d
29. will capture 100 events Alternatively the 199C and 196C can be set up in waveform compare mode to store only matching Pass or only non matching Fail acquired wave forms in the replay memory bank for further analysis Replay Manual or continuous replay Displays the captured 100 screens as a live animation Each screen is labelled with date and timestamp The contents can also be viewed by manually scrolling backwards and forwards screen by screen Replay storage Up to 2 sets of 100 screens each can be saved for later recall and analysis Waveform Compare and Pass Fail Testing Waveform compare Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms Reference is derived from an acquired waveform and can be modified in the ScopeMeter or externally using FlukeView Software Pass Fail Testing 199C 196C In waveform compare mode the Color Scopemeter can be set up to store only matching Pass or only non matching Fail acquired waveforms in the replay memory bank for further analysis Automatic Scope Measurements Vdc Vac rms Vac dc Vpeak max Vpeak min Vpeak to peak Aac Adc Aac dc frequency Hz risetime fall time power factor Watts VA VA reactive phase pulse width pos neg dutycycle pos neg temperature C temperature F dBV dBm into 50 Q and 600 Q Vpwm ac Vpwm ac dc for measurement on pulse width modulated motord