APCEM Instruction Manual
Contents
1. INSTRUCTIONS ourepilor DESKTOP CO2 MONITOR APCEM INSTRUCTIONS OVERVIEW Thank you for selecting the APCEM desktop CO monitor It is smart compact and easy to use In addition to measuring the CO concentration The APCEM can also measure the ambient temperature and the relative humidity This product is developed to detect the presence of CO in ambient air and help plants to grow well The APCEM can be used in greenhouse hydroponics room and other place where plants need to grow well FEATURES e The built in Data logger can store 48 sets of CO and temperature and RH in the past 24 hours one log per 30 minutes e Max Min mode can record the maximum and minimum concentration of CO since the device has been last turned on e The RCFS Mode can recover the original factory settings after the CO device has been recalibrated altered or damaged 1 Enter Button 4 Mode Button 7 Yellow LED Display 300 1300ppm 10 Power inlet 5 LCD display 8 Green LED Display gt 1300ppm 11 RJ45 socket only for factory use 3 Up Button 6 Red LED Display lt 300ppm 9 Gas Entry Hole SE RoFS MAXMINLOG CALIBRATING co U59 e ERE 85 2055 ER A Re 005 60 LE T ALTI ALARM12 OUTSIDE ZG1f63R CO2 Monitor LU oi II MODE FUNCTIONS There are several Modes which can be adjusted by user These modes are ALTI Mode OUTSIDE Mode CALI Mode LOG Mode MinMax Mode and RcFS Mode in sequence Compensate
2. Kaufdatum gilt jenes Datum das dem Kaufticket im Original zu entnehmen ist APCEM Instructions rev 08 07 2015 www Hydrofarm com
3. OOTING amp SPELS SPECIFICATIONS CO SPECIFICATION Measurement Range 0 3 000 ppm display Display Resolution 1ppm at 0 1 000ppm 5ppm at 1 00172 000ppm 10ppm at 2 001 3 000ppm 0 2 000ppm 70 ppm or 5 of reading whichever is greater over 2000ppm Accuracy 7 o Typ 0 2 of reading per C or 2 ppm per C whichever is greater referenced Temperature Dependence to 25 C Pressure Dependence 0 13 of reading per mm Hg Corrected via user input for altitude i 0 Repeatability 20 ppm 400ppm About 2min for 63 of step change o Red lt 300ppm Yellow Warm Up Time lt 60 seconds at 22 C Zone LED Display 300 1300ppm Green gt 1300ppm TEMPERATURE SPECIFICATION 0 C to 50 C 32 F to 3 3 Temperature Range 122 F display Display Resolution 0 1 C 0 1 F 5 20 30 minutes case must a pone TIME equalize with environment 1 C 2 F When the fan blows to the device directly the accuracy of temperature is 1 5 degC Accuracy RH SPECIFICATION Operating Conditions Measurement Range 20 90 RH 0 C to 50 C 32 F to 122 F Temperature Display Resolution 1 RH Humidity Range 0 95 RH non condensing Accuracy 5 RH 23 C Storage Conditions i o Response Time L 4 11 Storage 20 C to 60 C 4 F to 140 F change Temperature POWER SUPPLY Power geg 100 240 VAC 50 60 Hz 6 VDC from external AC DC adapter which is included in ER package Use specified AC adapter only FAUL
4. OR PRODUCT To ensure you receive the maximum benefit from using this product please observe the follow guidelines 1 1 Cleaning Disconnect the power before clean Use a damp cloth Do not use the liquid cleaning agent such as benzene thinner or aerosols 2 2 Repair Do not attempt to repair the product or modify the circuitry by yourself Please contact with the local dealer or a qualified repairman if the product needs servicing 3 3 Air circulation The vents allow the air circulation liquid for measurement of the CO2 concentration and the ventilation should not be blocked CUSTOMIZE SETTINGS CUSTOMIZE SETTINGS When the power has been connected the APCEM CO2 monitor will begin to work In order to meet your personal requirements it is advisable to set up the customizing parameters WarmUp It lasts approximately 1min before WARM UP disappears all MODE functions will not response during warm up TEMPERATURE 2C 2F RH AND VENTILATION RATE a DBS wes 0652 mes 10652 ce 0 10652 me 2057 GOs BUTTON me 6097 E Burton 19 m EI Burton 169 60 V _ 1 Press up down to select the temperature RH and ventilation rate modes 2 When pressing up button the LCD display sequence is Temp 2C gt Temp gt gt Vent Rate Ips gt Vent Rate cfm p When pressing down button The LCD display sequence is reverse NOTE Temp C refers to Temperature in Celsius Temp 2F refers to
5. T CODES amp TROUBLESHOOTING GUIDE FAULT ICON DESCRIPTION OF THE FAULT SUGGESTED ACTIONS The ambient temperature has exceeded the This error will clear when the operating temperature range 0 C to 50 C temperature returns to the range 32 F to 122 F between 0 C to 50 C 32 F to 122 F Please reconnect AC adapter to the APCEM CO2 Monitor If the Err5 EEPROM System problem Err6 still appears please contact the Service Department for further assistance WARRANTY Year Warranty LIMITED WARRANTY Hydrofarm warrants the APCEM to be free from defects in materials and workmanship The warranty term is for one year beginning on the date of purchase Misuse abuse or failure to follow instructions is not covered under this warranty Hydrofarm will at our discretion repair or replace the APCEM covered under this warranty if it is returned to the original place of purchase To request warranty service please return the APCEM with original sales receipt and original packaging to your place of purchase The purchase date is based on your original sales receipt GARANTIA LIMITADA Hydrofarm garantiza que APCEM no presenta defectos en los materiales ni la fabricaci n La vigencia de la garant a es un a o que comienza en la fecha de compra Esta garant a no cubre el uso err neo el abuso o el incumplimiento de las instrucciones Hydrofarm segun si criterio reparar o sustituir APCEM incluido en esta garantia si se d
6. Temperature in Fahrenheit Vent Rate Ips refers to Liter Per Second Vent Rate cfm p refers to Cubic Feet Per Minute INSTRUCTIONS USING THE ALTI MODE o EGR mee IDES ze DES MODE ENTER me COS BU BUTTON we d 60 BUTTON 0a 60 XL Bi MG J um J N D 1 Press Mode be ALTI icon flashes 2 Press Enter ALTI shows on the display press the mode button to alter between the m meter and ft feet 3 Adjust altitude step 100m 500ft by up down button 4 Press Enter again to save the data USING THE OUTSIDE MODE co ESA ze p DER 2 065 MODE ENTER me OD ew BL BUTTON re COS m 60 BUTTON 105 Smor 60 PA 1 Press Mode the OUTSIDE icon flashes 2 Press Enter shows OUTSIDE CO2 and ppm flashes Press the Up Down to adjust the data 3 Press Enter to save the setting After the modification the VENT Rate will change NOTE Ventilation rate represents how much air is introduced into the indoor space from outside Low numbers indicate low ventilation rates and potentially poor air quality High levels indicate excessive ventilation and potential excessive energy usage To obtain an accurate measurement reading should be taken 2 3 hours after occupancy has stabilized in a space or at a peak in daily CO2 concentrations For indoor air quality control CO2 value is an indicator of ventilation rate 400ppm Parts Per Million is the default CO2 concentration outside ac
7. cording to ASHRAE Ameri can Society of Heating Refrigeration and Air conditioning Engineers USING THE CALI CALIBRATION MODE a ESA ze a D A oes IDES MODE ENTER me 005 60 BUTTON m 205 60 Button 105 Smo bi 1 Expose the unit to fresh air by bringing it outside Avoid direct contact with automobile exhaust furnace exhaust etc DO NOT BREATH ON THE UNIT DURING THE CALIBRATION PROCESS Connect the power supply 2 Move away from the unit to allow the reading to stabilize for approximately 20 minutes 3 Press Mode the CALI icon flashes 4 Press enter the screen shows the CALI icon without flashing 4 www Hydrofarm com INSTRUCTIONS 5 Press Mode for more than 10 seconds CALIBRATING flashes Calibration will be done automatically after about 3 minutes and the LCD will display PASS or FAIL If it shows FAIL please try again 6 After calibration is complete disconnect power supply for a few seconds USING THE LOG MODE o DESA an o DBS a a OBSA MODE ENTER me C09 m BU BUTTON re CUS BOs BUTTON we COS m 60x 1 Press Mode LOG icon flashes 2 Press Enter CO2 reading and Temperature show on the LCD 3 Press Up Down to page up down the reading NOTE With the Built in Datalogger the APCEM can provide the past CO2 temperature and RH reading within the past 24 hours The log interval is 30 minutes per data APCEM is connected with power and used fo
8. evuelve al centro original de compra Para solicitar el servicio de garantia devuelva APCEM con el tique de compra y el embalaje originales a su centro de compra La fecha de compra se basa en su tique de compra original GARANTIE LIMIT E Hydrofarm garantit que APCEM ne pr sente pas de d fauts de mat riel ni de fabrication La garantie est en vigueur un an partir de la date d achat Cette garantie ne couvre pas l utilisation incorrecte labus ou le non respect de la notice Hydrofarm selon ses crit res r parera ou remplacera APCEM couvert par cette garantie s il est renvoy au centre original d achat Pour demander le service de garantie renvoyer APCEM avec le ticket d achat et l emballage originaux au centre d achat La date d achat est indiqu e sur le ticket d achat original BEGRENZTE GARANTIE Hydrofarm gew hrleistet dass APCEM ohne Material und Herstellungsmangel geliefert wird Die Garantiedauer betragt ein Jahr und beginnt zum Kaufdatum zu laufen Schaden die aufgrund eines unsachgemafsen Gebrauchs oder der Nichteinhaltung der Anleitungen entstehen sind von der Garantie nicht gedeckt Hydrofarm wird den unter Garantie stehenden APCEM nach eigenem Ermessen entweder reparieren oder ersetzen sofern die Ruckgabe an der Verkaufsstelle an der er erworben wurde erfolgt Fur die Beantragung der Garantieleistungen ist der APCEM mit der Quittung und in der Originalverpackung an der Verkaufsstelle zuruckzugeben Als
9. r the first time If the working time is more than 30 minutes the APCEM will have CO2 RH and temperature reading in datalogger if the working time is less than 30 minutes the LCD will display NULL while using the LOG function USING THE MAX MIN MODE o hte fo CO 055 o CO 055 e CO 055 Lan CO 055 205 50 me 205m 60 BUTTON D 60 BUTTON CL r m 60 iS 1 Press Mode the MAX MIN icon flashes 2 Press Enter the MAX and MIN CO2 reading alternatively shows 3 Press Down and the CLr will flash on the LCD Press Enter to CLEAR the MAX and MIN record NOTE With the Built in MAX MIN mode the APCEM can provide the Maximum and Minimum CO2 readings since the device has last been turned on If users press up down to clear the MAX and MIN CO2 reading record the APCEM w ill provide the new MAX and MIN CO2 reading from that time INSTRUCTIONS USING THE RCFS MODE a DESA os i0652 e no ae HEES me 205 504 BUTTON mo d E BUTTON me 205 60 BUTTON mo 205 60 1 Press Mode The RcFS icon flashes 2 Press Enter the icon no shows on the LCD Press the Up Down to select the no yes 3 After selecting press Enter to save the setting NOTE If the user sets the data or calibrates the the APCEM incorrectly use the RcFS recover the factory Setting to come back the default factory setting D www Hydrofarm com TROUBLESH
10. the m gt Modify the outside pressure changes with co IU bb OUTSIDE CO concentration appropriate altitude of for calculating the location when measure bg di m bl ventilation rate Calibrate the sensor Show the past CO while the reading CO H dech Temperature and RH CO IU nec deviates from the actual records in the past 24 CO concentration m SKI hours 005 bls BS factory setting to cancel being cleared or after customize setting we 005 60 SE 205 50 Show the Max and Min CO reading before co IU EG Di E CO UI 0652 2 www Hydrofarm com INSTRUCTIONS SAFETY INSTRUCTIONS N WARNING Your safety is very important to us To ensure to use the product correctly and safely we ould like to draw your attention to read the warning and entire User Manual before us ing the product These are important safety information and should be observed at all times 1 Please handle the devices lightly do not subject the product to impact or shock Do not immerse the product in water Water can cause electric shock fire or malfunction which may result in damage 3 Do not keep the product in a hot and moist environment Keep the product away from the heat source or near water 4 Please use only the included power adaptor Improper power adaptor or power sources can cause serious damage to the product or result in injury or death to the user CARING F