Home

REACH SD Encoder ENC110

image

Contents

1. Copyright Shenzhen Reach IT Co Ltd 11 12 User Manual REACH REACH ENC110 SD Encoder 2 7 3 Caption setting Through the caption setting you can set captions in the image acquired by the encoder The caption position can be set thorough the horizontal coordinate and vertical coordinate parameters To ensure the consistence between the image acquisition time and local time you can synchronize the time through TE Synchronize Subtitles Setting P Display Time TE Synchronize Content 2 7 4 PTZ setting and control The remote control of the camera can be realized through the SD encoder Before using the PTZ control function of the encoder please check the control protocol of your camera The SD encoder currently supports VISCA PELCO D and PELCO P protocols PTZ Protocol i FTZ Control et o We Speed O Low Medium High Copyright Shenzhen Reach IT Co Ltd 12 12
2. REACH SD Encoder ENC110 User Manual V2 5 2012 01 Copyright Shenzhen Reach IT Co Ltd User Manual REACH REACH ENC110 SD Encoder Shenzhen Reach IT Co Ltd provides full technical supports for the customers If you have any inquiries please contact the local Reach office or directly contact the headquarters of the company Shenzhen Reach IT Co Ltd Address Unit 601 Block B Kingdee Software Park No 2 Postal code Technology Southern No 12 Rd South District of 518057 Hi Tech Industrial Park Nanshan District Shenzhen Website http www szreach com Tel 0755 86073600 Customer 4007160868 service hotline Customer 0755 86073689 service fax Copyright Shenzhen Reach IT Co Ltd 2011 All rights reserved Any part of this document including the text image and graph is the property of Shenzhen Reach IT Co Ltd No part of this document shall be copied in any means without the prior written consent of Shenzhen Reach IT Co Ltd Reach reserves the right to revise this document without any prior notice Reach provides warranty of limited liabilities for the software and hardware product For any loss of the users caused by the design defect of the software and hardware Reach will compensate the user with the amount up to the price specified in the product purchase contract Trademark Statement gwe Reach REACH Pss and Reach Software are the trademarks of Shenzhen Reach IT Co Ltd Windows
3. Windows 95 Windows 98 Windows NT Windows 2000 Windows 2003 Windows XP and Win are the trademarks of Microsoft Other trademarks are the properties of their respective owners Note This user manual is compiled to ensure easy installation and configuration of the product Please read carefully this manual before using the product so that you can make best use of all its functions This manual is subject to update from time to time without prior notice If you come Copyright Shenzhen Reach IT Co Ltd 2 12 REACH REACH ENC110 SD Encoder User Manual across any problem that cannot be solved according to the manual please contact our technical department for solutions Thank you Copyright Shenzhen Reach IT Co Ltd 3 12 User Manual REACH REACH ENC110 SD Encoder Contents Be e Tt ee 5 e Relief edu tee Ee Le une 5 1 2 Product Palamelers unse re a nennen een en 5 1 3 PIOQUC VE We en ee ee ee ei 6 1 4 Product Interface aus a eek ren 6 BO ele LIS EE 6 Product Configuration nun een Lee 7 h KIEL AN EE 7 22 IP Address VIG WING EE T 2 3 Normal Startup Confirmation sense ea 7 2 4 Logging on Encoder Configuration Interface 8 2 9 Dy SIC oe MN E 9 2 6 1 Set system language 1ccscecccsseeccseneecsasecsausecsaueeessauseesauseessuesessuesessunsessansessans 9 26 2 Change password een ee eA een ee eee en ene ne ee eee 10 2 6 3 Upgrade System EE 10 2 6 4 Change encoder IP address en nnnn en nnnnnnnnnnen nennen
4. automatically to complete the change 2 6 Parameter Setting Through the parameter setting you can set the frame rate code rate of the encoder to acquire the video audio signal the recording quality the coded image position as well as the caption adding function 2 7 1 Video setting Through the video setting you can set the coding frame rate for the encoder to acquire the video signal and the image mode The coding mode includes the fixed code rate mode and fixed quality mode The users with low available network bandwidth are advised to adopt the fixed code rate mode especially those with the activity of public network live broadcast They can adjust the coding bandwidth to the appropriate range in the fixed code rate mode Video Setting Video Frame Rate 25 de 30 video Mode 4CIF we Save 2 7 2 Audio setting Through the audio setting you can set the sampling rate and coding frame rate for the encoder to acquire the audio signal and select the audio acquisition interface according to the actual situation This product currently supports the acquisition of Mic audio signal and linear audio signal The users with low available network bandwidth are advised to adopt low audio code rate especially those with the activity of public network live broadcast They can adjust the audio code rate to the appropriate range according to the actual needs Audio Setting Sampling Frequency KHZ Bandwidth kbps Ome ue fo Save
5. 10 2 6 Parameter Sellind u ccssansenienn herein nenne nennen ee 11 ZA VIISO SOWA EE 11 Le AO ee EE 11 2 7 3 CPN SE e EE 12 2 7 4 PTZ setting and control 12 Copyright Shenzhen Reach IT Co Ltd 4 12 User Manual REACH REACH ENC110 SD Encoder I Product Overview 1 1 Product Introduction The SD encoder ENC110 is the special hardware equipment developed by Shenzhen Reach IT Co Ltd for SD video signal D1 CIF coding and network transmission It can be used together with the full range of Multimedia Record amp Play Servers of Reach The SD encoder adopts DSP processing chip and embedded operating system and features high stability and reliability This product supports WEB interface management and can be widely used in the applications that require the acquisition of SD video signal and IP based network transmission It meets the requirements of SD video conference teaching record amp play applications 1 2 Product Parameters Hardware parameters Outline dimensions L x W x H 240mmx 170mmx45 5mm Weight 1 35kg Environmental parameters Relative humidity 5 95 Operating temperature 20 C to 60 C Electrical specifications Operating voltage DC12V 3A Power consumption 8W Network interface LAN LAN interface connected to Intranet Copyright Shenzhen Reach IT Co Ltd 5 12 REACH REACH ENC110 SD Encoder User Manual 1 3 Product View Fig 1 REACH ENC110 SD Encoder 1 4 Product Inter
6. Co Ltd 9 12 REACH REACH ENC110 SD Encoder User Manual 2 6 2 Change password Change Password ee Enter the old password and then enter the new password and click save 2 6 3 Upgrade system Update System Upgrade File Browse Attention 1ittakes some time to Upload Updated file please do not make other operations while the file is uploading 2 After Uploaded a Updated file please restartthe system to complete the upgrade operation 1 Prepare the upgrade package 2 Click browse to locate the upgrade package file 3 Click upload 4 When the upgrade is completed the encoder will restart automatically You can view the system information to check whether the system upgrade is successful or not Note The upgrade takes about 3 minutes Do not perform any other operation during this period When the upgrade process is finished the system will restart automatically The system upgrade is completed after restart 2 6 4 Change encoder IP address IF Address Modification IF Address 192 168 23 3 Subnet Mask 55 755 0 0 2 Modify Attention 1 Please check the IP address carefully to avoid address conflict 2 The encoder will restart automatically after the IF address is modified Copyright Shenzhen Reach IT Co Ltd 10 12 User Manual REACH REACH ENC110 SD Encoder 1 Enter new IP address 2 Click change 3 The encoder will restart
7. face 1 2 3 4 5 6 1 Fig 2 Interfaces of ENC110 1 Power Input 5 Line In 2 Composite Video in BNC 6 LAN 3 Line Out 7 COM RS232 4 MIC In XLR 1 5 Packing List SE SD video signal acquisition and coding ENC110 encoder 1 set equipment Power adaptor 1 PCS To supply power to encoder To supply power to encoder power to encoder EN Network cable 1 PCS TTocomectLAN TTocomectLAN LAN To transmit the video audio signal to the Video audio cable 2PCS encoder To change the composite video interface of BNC connector 1 PCS the BNC and RCA connector Certificate of conformity Copyright Shenzhen Reach IT Co Ltd 6 12 User Manual REACH REACH ENC110 SD Encoder ll Product Configuration 2 1 Unit Startup Check the power cable and ensure that the power adaptor is properly and reliably connected to the unit When the power adaptor is connected to the encoder the PWR LED on the panel will be on indicating that the external power is connected and the equipment has started operation 2 2 IP Address Viewing The default IP address of the encoder is a random address You can view the IP address of the current encoder at the rolling information display field of the LCD panel Note For the convenience of illustration assuming that the IP address of the encoder is 192 168 1 100 and the subnet mask is 255 255 255 0 To ensure the normal network connection between your computer and
8. ield and then the following log on page will appear c REACH SD Encoder DSS ENC 110 Passwora ME CC Enter user name admin default administrator user Enter password admin default administrator password Note The default administrator account name of the system cannot be changed but you can change the password according to the actual needs Click log on button to enter the encoder management configuration page as shown in the following figure Copyright Shenzhen Reach IT Co Ltd 8 12 REACH REACH ENC110 SD Encoder User Manual SN HCS 8316AV Type DSS ENC 110 Core Version 1 0 8 System Version V1 2 2 Web version 1 0 8 IP Address 192 168 23 3 Subnet Mask 255 255 0 0 Gateway 192 168 6 1 MAC Address 48 91 F6 00 07 D7 The encoder system configuration interface mainly includes system information parameter setting system setting restart and exit 2 5 System Setting Select the system setting menu and then you can set the encoder system language change the password upgrade the system and change the encoder IP address 2 6 1 Set system language English Simplified Chinese The system supports simplified Chinese interface and English interface To set the system language you need to select the corresponding language and then click save The system will exit the log on interface and you need to log on the system again Copyright Shenzhen Reach IT
9. the encoder change the IP address of your computer to the same network segment of the encoder e g 192 168 1 110 255 255 255 0 2 3 Normal Startup Confirmation Before setting the IP address of the encoder check if the encoder has been normally started Open the command line mode window with the system tool For instance in the Windows system click Start run command to open the command line window and enter lt ping 192 168 1 100 gt in the command line window and then click Enter key If the following message appears it indicates that the encoder has been normally started Copyright Shenzhen Reach IT Co Ltd 7 12 REACH REACH ENC110 SD Encoder User Manual CH CO WINNT system327 cmd exe l K loj IC WINNT Ss ystem32 gt ping 172 168 1 160 Pinging 192 168 1 108 with 32 bytes of data Heply From 172 165 1 168 bytes s2 timetibns IL b4 Reply from 192 168 1 186 hytes 32 timeti me TIL 64 i i Reply from 192 168 1 188 bytes 32 time lt 1 me TTL 64 18 hytes 32 tinmetifms TIL 64 Reply From 1927 168 Ping statistics for 192 168 1 168 Packets Sent 4 Received 4 Lost CH loss Approximate round trip times in milli seconds Ainimun fins Maximum fins Average Aris 2 4 Logging on Encoder Configuration Interface The encoder has built in WEB server All the encoder configurations can be performed through the web browser e g Internet Explorer Enter 192 168 1 100 to the browser address f