1. 5 2 5 System PSW You can set new user password Please refer to the installation instruction Sound User PSW Adjustment Language System PSW Confirm 23 Click dim icon input the password the system will enter into the following interface please refer to the installation instruction IP Mask Gateway Server DNS 5 4 Room No Click icon input the password the system will enter into the following interface please refer to the installation instruction Building Door Device Sync 24 5 5 VOIP Click i icon input the password the system will enter into the following interface please refer to the installation instruction Realm Password Stun IP Stun Port 5 6 Upgrade a Click icon input the password the system will enter into the following interface please refer to the installation instruction za Upgrade 25 5 7 Version 1 Ul 1 1 0 20130201 std 2 RES 1 0 1 20130129 overseas 3 FW 1 1 1 20121208 4 MAC 00 1F D0 7C A9 2B 5 SLAVE 0 5 8 Adjust Screen A Warning End users are not allowed to set this feature please ask your installer for assistance When you touch the screen and find the icons cannot react normally please make the screen calibnation by yourself a Slowly sliding along the direction of arrow horizontal or vertical on the LCD as follows 26 b If your indoor monitor has O unlock button
2. During the communication with the visitor click BY icon to zoom in the visitor s image and click fey icon to snap the visitor s more images During the call Click a icon the system will record the video click jj icon the system will record the audio 2 2 4 Calling the management center The system can connect max 5 pcs management center Click i icon to call the management center when center 1 is busy it will call the next management center from 2 5 wy i Calling center 1 2 3 Records Click icon the system will enter into the following interface Date amp Time Address Image is refer to outgoing call is refer to received calls is refer to missed calls It stores the calling records The max quantity of records is 20pcs 11 Click amp Jicon the system will enter into the following interface Address Image b Return Click icon the system will display the visitor s image video and audio if recorded click B icon it will be paused click IE icon the system will return to the previous interface 2 4 Community message Note only install the management software on PC which usually locate at guard center the indoor monitor can receive the message sent by PC icon the system will enter into the following interface O puue _ S Date amp Time 2012 06 18 14 34 2012 06 18 14 24 amp is refer to the unread message When there are some unread messages the
3. interface Each sensor type can be set up as Smoke Gas PIR Door Window Panic Flood Pull Cord and Bed Mat F l Window Panic Flood Pull Cord Bed Mat When alarm sensor is triggered the indoor monitor will make a loud alarm sound the system will enter into the following interface and send alarm message to management center if your system installed management center You can see the No and sensor type in red color showed at the top of interface For example 2 Smoke 3 Smoke to indicate that Zone 2 and Zone 3 Smoke sensor are triggered To stop the alarm sound input the password the default password is 1234 1 3 Scene Mode Click kJ icon input the user password with 4 digits the default password is 1234 the system will enter into the following interface Bilis refer to Alarm ON is refer to Alarm OFF To set the sensor of alarm stations you can click the corresponding station with icon Remark If the system is on Alarm ON mode Scene Mode cannot be operated 1 4 IP Camera Click icon the system will enter into the following interface A Q Click a or a icon to select the IP Camera to monitor Click a icon to monitor Click icon to stop the monitor 2 Communication Click v icon in the main interface to enter communication interface it includes Monitoring Calling Records and Community message Monitoring Calling Records Community Message 2 1 Monitoring Cli
4. is closed if click o icon the curtain is paused 3 5 Elevator Click Licon the system will enter into the following interface 1 ELEV Available Floor Click E or HE to control the elevator to up and down Click icon to open the floor that the indoor monitor locates Remark To support this interface your system must connect with Elevator Control module Kindly check with your system provider 15 3 6 Room Settings Click icon to enter into room settings interface 3 6 1 Room You can add delete room data and change the room name The room types includes Living Dining Master Sub Study Kitchen There are max 20 rooms you can set After setting click M icon to save it a d 3 6 2 Light There are max 8 routes light for each room You can set the corresponding room s lamp Choose the room type firstly then you can set the name for each light the lamp includes Lamp Wall Ceiling Table Floor Pendant Crystal and Spot Click g or v icon to see all lights After setting click M icon to save it a a 16 4 Multi media icon to enter into the following interface hy na amp Aje Voice Message Music Player Video Player Photo Frame 4 1 Voice message Click icon to enter into the following interface hy ai Click icon to record The longest recording time is 30 seconds Click con to stop recording and store it If the recording time is
5. press this button on the indoor monitor for 5 seconds the system will enter into the following interface Then click the center of cross intersection from to in turn After adjustment the system will be exited automatically 27
6. video intercom between each indoor monitor 7 Communicate with VOIP PSTN or mobile phone 8 Support Web Browser appointed by system provider 9 Connect max 6pcs indoor monitors in one house 10 Image video audio records from outdoor panel 11 Message receiving from management center Max 60 pcs 12 Answering machine with video audio message 13 Multimedia playing such mp3 mp4 and photo frame with SD card 14 Support Smart Home control module 15 Easy installation use international standard RJ 45 16 Use TCP IP protocol base on LAN network no distance and apartment quantity limitation multi channel intercom 17 Easy maintenance automatic fault detection software upgrade with SD card Technology Parameters Voltage DC 12V Rated power 6W Standby power consumption 2 5W Display screen 7 10 2 Resolution 800 480 1024 600 Operating temperature 0 C 50 C Relative huminity 20 93 CPU 350MHz Memory DDR2 1 Gbit 2 Flash 16Gbit Max SD card capacity 32G We just use the below picture as an example to describe the feature of each icon NZ Power indicator Hand free Photo frame Message indicator D Calling management center Alarm setting indicator Alarm indicator amp Monitoring rr O Unlocking SD card port ao ior A N m d Gc th a C Microphone USB port AN ba Home Security Communication Home Con
7. IF etc formats can be supported for picture Each picture should be less than 1M If it is on stand by mode for 2 minutes the system will switch into screensaver mode If there is no image in SD card the screensaver will display as the clock if there are some pictures in SD card the screensaver will display pictures which are stored in SD card the screensaver time is about 10 minutes 5 System Settings Click icon to enter the following interface for A VOIP Upgrade Version 19 5 1 Normal Click J icon to enter the normal setting interface Normal setting includes Intercom Date amp Time and Wallpapers 5 1 1 Intercom The system supports video intercom between each indoor monitor when the camera is set as ON it allows other indoor monitor can see you by your camera when it is set as OFF this feature is not allowed Answering machine set Video and Audio REC as ON when someone calls but indoor monitor has no answer it will auto answer and make video amp audio record set Video REC as ON it will auto answer and make video record only set Audio REC as ON it will auto answer and make audio record only Kindly note that SD card should be inserted in it and the record can be reviewed in the communication record Monitor you can set the default monitoring object Wallpapers Audio REC OFF 7 Camera Monitor Main vV 5 1 2 Date amp Time You can set Time zone Date and time After setting c
8. Operation Manual For TCP IP with SIP Digital 700 System The Seasons Series a Indoor Monitor Remark Please follow the user manual for correct installation and testing if there is any doubt please call our tech supporting and customer center Our company applies ourselves to reformation and innovation of our products No extra informing for any change The illustration shown here only used for reference if there is any difference please take the actual product as standard product lt gt Product Features nnn nnn tnnnnnnnnitnnniinnsiinnisnntnnanninnsnetit Technology Parameters rten Product PICTUIES vitsttssrsrtsssssrrrtreestsssrrrereestnsssrrereeennsnsrrrrreeentnnrrereent Oe eee ee a ee 1 HoMe Security iien 2 Communication Sige eee acca cca tn uaa cou ented ede eect taeeaecatencscued erty lebeteettoes iucutcaeceiiaedd 3 Home Control ee nee eee eee ee 4 Multi media ee ee 5 System settings E TEE EE E E E Product Features 1 7 or 10 Touch screen 2 Friendly interface easy change to match with your decorative style The seasons spring Summer autumn and winter bring you different feelings 3 Intercom with Outdoor panel flat panel and Management Center 4 Support 8 alarm stations can be extended to 16 alarm stations Emergency Smoke Gas IR Magnetic contact for door or window 5 Monitor Max 8pcs IP cameras ONVIF protocol 6 Audio
9. ck a icon to enter the following interface A Q Click Maint icon to switch into monitoring Main or Sub door panel Click or gt icon to select the monitoring object When select Main 1 9 it monitors outdoor panel when select Sub 1 9 it monitors the flat panel Click icon to monitor click oa icon to cancel the monitor click icon to unlock the door 2 2 Calling 2 2 1 Calling Other Indoor Monitor Input 1 to 4 digits Building 1 to 2 digits Door 1 to 4 digits room No then click ewe icon For example you would like to call indoor monitor 0001010807 You can input 1 and click Building icon then input 1 and click Door icon and then input room No 0807 finally click Bicon Click icon to delete the wrong input Q sommunication _ 2 2 2 Calling your sub Indoor Monitor If it connects with sub indoor monitor click icon to select the corresponding device to make internal intercom 2 2 3 VOIP phone You can dial the phone number which registered in the SIP server then the system will get through the phone Please refer to the installation instruction about VOIP setting 2 2 3 Answer the call When someone calls in the system will enter into the following interface 1 1 705 Call in Click J icon to answer the call click icon to hang up click icon to unlock the door If one calls the monitor and no one answers the system will snap the visitors 1pc image automatically
10. iconWQin the interface will light up and when enter the message interface the icon will light off Click icon to page up click M icon to page down click icon to delete the record 12 3 Home Control Attention Home control function should be connected with smart home module to use otherwise this function is invalid In the main interface click icon the system will enter into the following interface E cae aa q r 1 Air Condition Bo Elevator Room Settings 3 1 Scene Mode cick icon the system will enter into the following interface OOGO Home Out Sleep Party Dinner Scene mode includes Home Out Sleep Party and Dinner 13 3 2 Light Click icon to enter the following interface Living Set the light of corresponding room such as Master Sub Living and Dining see the room setting for details 8 lights can be set in every room at most Click the corresponding light icon then you can control the light turn ON OFF 3 3 Air condition Click icon to enter the following interface Living Dining i Set the air condition switch of corresponding room Click icon to turn air condition on off click Eicon to cool click icon to heat click icon to ventilate 14 3 4 Curtain Click T icon in the home control interface the system will enter into the following interface Living Click Gi icon the curtain is open if click icon the curtain
11. lick to save it The date and time on the main interface will be adjusted accordingly TimeZone DateTime 20 Remark When the power recovers after outage the date and time will be returned to factory default mode you must set it again If the indoor monitor connects with management software or Internet the date and time will be synchronized automatically 5 1 3 Wallpapers In this interface you can choose the wallpaper you want Four types of wallpapers for option Spring Summer Autumn and Winter After setting click to save it Intercom Date amp Time Valasa Summer 5 2 Others Click icon the system will enter other settings interface 5 2 1 Sound You can set System and In call volume also set Ring and Press type After setting click to save it User PSW Adjustment Language System PSW System O o In call VOL a_j Ring v Press 21 5 2 2 User PSW You can set new user password The default password is 1234 User password is used for Home security After setting click to save it Adjustment Language System PSW Confirm 5 2 3 Adjustment You can set Brightness and Contrast After setting click to save it Sound User PSW ET Language System PSW Brightness Contrast A Ke 29 5 2 4 Language You can choose the language you want After setting click vy Ee save it Sound User PSW Adjustment EIET System PSW English
12. reached to 30 seconds the system will end the record and save it automatically Select anyone in records click icon to play Click o icon to delete the selected record Click or E icon to listen the previous or next voice message 17 4 2 Music player Click a icon to select the file catalogue of SD card then select the music folder Select a song then click icon to play it Click O Acon to select songs Click icon to stop playing the music The playing type can be set Chaos and Cycling Click icon to random play the music click E icon to cycle play the music WAV Mp3 etc formats can be supported for music gt Dasss gt 4 3 Video player Click gjicon to select the file catalogue of SD card then select video folder The system will enter into the following interface 2 Dasss a Select one video click icon to play in full screen click the screen again to quit the full screen mode If it has incoming call during video playing the video will be pause After the call the video will recover to playing from breakpoint automatically to keep on playing the video after the call AVI MP4 MOV WMV RMVB MPG etc formats can be supported for video 18 4 4 Photo frame Click icon then search SD card or picture files in USB flash disk select picture folder then the system will enter into the following interface double click the selected picture to browse in full screen JPG PNG BMP GIF T
13. ring the alarm delay time Click icon the system will sound a tone then the alarm is stopped 1 1 3 Alarm OFF If the system is on Alarm ON mode and need to cancel the alarm now you must input the user password with 4 digits the default password is 1234 Password 1 2 Setting Click icon then input the user password with 4 digits the default password is 1234 the system will enter the following interface Sensor Delay refer to the delay time of alarm on It can be set as following Os 30s 40s 60s 100s 300s For example if you set it as 30s it will be alarm on after 30s Remark If the system is on Alarm ON mode zone setting cannot be operated 1 2 1 Alarm Type Click type input box it will popup a dialog box as the following In this interface you can set alarm Type as 24H Normal and Emergency 24H and Emergency type are always active ay 1 2 2 Delay Time It refers to the delay time of giving an alarm Click Delay setting box it will popup a dialog box as the following interface with followings Os 5s 10s 15s 20s 25s 40s and 60s and choose the desired delay section For example you select the delay time 5S Once the alarm sensor is triggered 5 seconds later the indoor monitor will sound sirens A Zonet 24Hour Zone2 24Hour 24Hour 24Hour 1 2 3 Sensor Type Click sensor type input box it will popup a dialog box such as the following
14. trol Multi media System Settings iE Service Call amp Info T W H Main interface Home Security Communication Home Control Multi media and System Settings Status bar Service Call amp Info SIP mark Voice message Alarm status Mute mode Community message and Network mark Status bar instruction 1 Service Call info to browse the appointed website 2 SIP mark When register SIP server successfully the mark is lighted 3 Voice message Q Click to listen the voice message 4 Alarm status it will flash and you ll hear DI DI tone when setting up to indicate your alarm sensors will be actived after 100 seconds 5 Mute mode CD Click to set ON or OFF of mute mode 6 Community message FJ Click to read the community message 7 Network mark 64 Connect with network properly or not 1 Home Security Each indoor monitor can be connected with max 16 alarm zones Click icon igon the main interface the system will enter the following interface Alarm ON OFF Setting Scene Mode IP Camera Three security alarm models for option At home Outside and Sleep Athome Outside 1 1 Alarm ON OFF 1 1 1 To Alarm Click At home Outside or Sleep icon to active the alarm sensors the icon Bj on the main interface will light with a Di Di tone After the delay time the security alarm will operate and this icon will always light up 1 1 2 Stop Alarm Du