1. 2 to 100 2 to 100 2 to 100 2 to 100 63mm to 2500mm 63mm to 2500mm 63mm to 2500mm 63mm to 2500mm sds 3 2 to 100 63mm to 2500mm 2 to 100 63mm to 2500mm 500 2 to 100 63mm to 2500mm 500 2 to 100 63mm to 2500mm 500 Note Consult the factory for an updated list of pipe materials _ oO 3 3 3 Steel carbon m a gt 3 x 13mm Accuracy Flow Rate Averaging Time Transit Time Accuracy at at Nominal Pipe Sizes 1 of rate gt 1 ft sec 0 01 ft sec lt 1 ft sec 1 of rate gt 5 ft sec 0 05 ft sec lt 5 ft sec 2 of rate gt 12 ft sec 0 25 ft sec lt 12 ft sec 5 0 Seconds default setting 1 0 Seconds 0 5 Seconds Flow Rate Averaging Time 5 0 Seconds default setting Doppler Accuracy at Nominal Pipe Sizes 2 of rate gt 12 ft sec 0 25 ft sec lt 12 ft sec 2 of rate gt 12 ft sec 0 25 ft sec lt 12 ft sec 2 of rate gt 12 ft sec 0 25 ft sec lt 12 ft sec 1 0 Seconds 0 5 Seconds Shipping Specifications Carton Dimensions 21 x 17 x 9 1 2 Carton Weight 24 Ibs 10 9 Kg aia ol 3 3 Ss S lt lt x lt e pra Q oO 3 3 3 3 gt x SPU Signal Processing Unit Enclosure NEMA 4X IP66 Powder coated aluminum SS cla
2. A AIA lw QIN Metric Pipe Size a ON aw 3 3 3 3 Omm Omm 25mm KININ aja 4 4 4 je 0o63 oso 110 _ 125 140 160 180 200 _ 225 250 _ 280 2 315 355 400 450_ 500 _ 560 630 _ 101 S S S E SK __ Sch5 ASTM D 1785 _ _ 5B Sch 20 ASTMD 1785 ISD_ Sch40 ASTMD 1765 SE __ Sch 60 ASTM D 1785 SF__ Sch 80 ASTM D 1785 __ ISG Sch 100 ASTM D 1785 SH_ Sch 120 ASTM D 1785 s Scn 140 ASTMD 1785 IDA SDR41 ASTMD 224 DB_ SDR 26 ASTM D 2241 DD_ SDR 13 5 ASTM D 2241 _ _ PB__ PN 6 Metric DIN 8062 _ PD__ PN 16 Metric DIN 8062 _ _ PE PN 20 Metric DIN 8062 BD_ CLASS D British BS 3506 BE CLASS E British BS 3506 Pipe Material JA Brass Naval B Copper ID firon cast o E lron ductiley o F nyn OOOO SSS S e _ Polyethylene HDPE H Polyethylene LDPE Polypropylene K PVDF o IM__ Stainless Steel 304L_ IN Stainless Steel 316 0 o Steel 1 Carbon hardened P Steel carbon Q Titanium o 9 225 in 234 mm 3D 0 0 in Signal MEEO W42 Rate U S Gallons min M e E E y o E E e e With Wall Mount Hardware Watersa SSCS AN Water sea User configured 1 Unless equipped with the communications option and user software models S1 and S2 are factory configurable only A Pipe 2 to 100 63mm to
3. e 0 1000 Hz Pulse output fully configurable invertible Data Logging Date time stamped flow rate and flow total data in FAT32 file format easily imported into Excel Configurable to trigger on time interval 1 999 999 sec rate and or total set point values Over 500 000 log events possible with included 32MB SD Card Process Control Three independently configurable 10 amp Form C NO NC relays e Configure to flow rate for high low range rate alarm Programmable release values enable auto release or manual latching operation e Configure to flow total for manual trigger batch operations or automatically triggered timed batch operations External Communications Computer connection via RS 232 RS485 USB Ethernet e Includes user communication and configuration software e Permits remote internet access through local network set up e Remotely access and upload data logging files Clamp On Transducers Housing NEMA 6P IP67 Nickel plated aluminum SS clamps amp hardware Dimensions 3 12H x 2 95W x 1 60D in 79H x 75W x 41D mm Weight excluding cable 0 8 Ib 0 4 kg each Cable Shielded coaxial RG U Type 59 PVC jacket black ROHS Compliant Standard length 10 ft 3m Optional lengths available 25 ft 7m 50 ft 15m 100 ft 80m Pipe Surface Temperature 20 F to 300 F 34 C to 150 C 3 of 4 TDS 85000 077 rev 06132008 SONIC PRO Ultrasonic Flow Meters Engineering and echnical Data
4. 2500mm Cable Length 2 Smart Communications Option B process control relays requires either the S3 configurable display or the communications option for relay configuration 010 10feet 025 25feet 050 _ 50feet_ 100 100feet 3 Other display volume units including custom units are available Contact the factory for ordering information 4 Not all pipe sizes pipe pressure ratings pipe materials and fluids are shown here Contact the factory for more information 5 The basic Sonic Pro model number includes one set of transducers Optional transducer set ordering information is shown to enable ordering replacement or secondary sets All trademarks are the property of their respective owners 4of4 TDS 85000 077 rev 06132008
5. Dimensions 8 600 in 5 000 in 3D0 0in Signal 9 MMO W42 Rate U S Gallons min 11 70 in 297 mm 11 00 in 279 mm ee ee Model Number Matrix 750 in 19mm 1 513 in 38 mm 20 mm TYP 7 826 in 199 mm 264 mm 2 95 in 75 mm ra B TRANSDUCER Series A and B Sonic Pro Ordering Information Sonic Pro Part Number Matrix Base Electronics Package Factory configured without display 1 Factory configured with display Factory configured with user configurable display Smart Communications and Control Communications Includes Ethernet USB RS 232 RS 485 connections and user configuration and monitoring PC software A Process control Includes three 10 amp form C relays iti Recon a dei ortecormancaine ton 1 U S 125VwithNEMAS 15 plug OO OO O OOS 2 European 250V with CEE 7 Vilpug SSS C3 U S 250V wth NEMAG 5plug SOS Model A with 25 ft cable Model A with 50 ft cable Model A with 100 ft cable N minal Pipe Size Select from options list o elect from options list Pipe Material Display language E English ooo y Ps Spans O O G German oo y O E French oS s3 c 1 a1 o60 so y c m ac EOTS Optional replacement set of transducers Notes Ula O pA oy Q N N 9 es N Q NINININ TT w w NJQ W gt A oo
6. ProSeries SONIC PRO_ Ultrasonic Flow Meters Engineering and Technical Data SONIC PHO S3c Hybrid Ultrasonic Flowmeter gt E Pral Fyi gt at Be Selectable Doppler or Transit Time Non Invasive clamp on transducers High quality QVGA display NEMA 4X IP 66 washdown enclosure Full function front panel interface Smart external communications Process control features pt tp PE Liq id Applications ff NEMA4X CE GD A L O TO N Applications Features e Sewage e Selectable Doppler or Transit Time operating mode e Custom quality metric algorithms and DSP technology ensures reliable high e Wastewater accuracy measurements e Pulp amp Paper Slurries e Quick and easy clamp on transducer installation Proprietary AGC Automatic Gain Control algorithm eliminates manual gain adjustment Di water e User programmable via 5 button menu driven interface e Discharge water e Factory configured for easy installation Includes five user programmable password protected configurations for multiple user and portable applications e Caustics e High quality 320 x 240 pixel QVGA backlit LCD e Chemical Slurries e Data logging to standard SD Card format User configurable to time interval flow rate and total set point triggers 500 000 events with included 32MB SD Card Ground water e Isolated 4 20 mA output fully configurable e Food and Beverage e 0 1000Hz Pulse
7. equired for accuracy will depend on the type of disturbance Minimum Straight Pipe Length Requirements The meter s accuracy is affected by disturbances such as pumps elbows tees valves etc in the flow stream Install the meter in a straight run of pipe as far as possible from any disturbances The distance required for accuracy will depend on the type of disturbance Type of Disturbance Straight Lengths of Pipe Required Upstream from Transducers Downstream from Transducers Two 90 Elbows 1 Direction 15 x Nominal Pipe Size 5 x Nominal Pipe Size Two 90 Elbows 2 Directions 20 x Nominal Pipe Size 5 x Nominal Pipe Size Gate valve or Pump 25 x Nominal Pipe Size 5 x Nominal Pipe Size Transducer Mounting Location The meter can be mounted on horizontal or vertical runs of pipe Mounting on the sides 3 o clock and 9 o clock position on horizontal pipe is recommended Mounting anywhere around the diameter of vertical pipe is acceptable however the pipe must be completely full of fluid at all times Back pressure is required on downward flows to ensure a full pipe See the minimum straight length of pipe requirement chart above The meter can accurately measure flow from either direction NO Pipe must be full Air bubble Down flows must have L gt 10D k gt T See minimum straight length requirements above NO Sediment 2of4 TDS 85000 077 rev 06132008 SONIC PRO Ultrasonic Flow Me
8. mps and hardware Dimensions 11 00H x 8 60W x 5 00D inches 279H x 218W x 127D mm Weight 9 5 Ib 4 3 Kg Mounting Wall pipe vertical or horizontal or panel mounting Hardware included Panel opening 10 63H x 8 10W inches 270H x 206W mm Panel Depth Rear 2 78 inches 71 mm Front 2 18 inches 55 mm Power Requirements 95 264 VAC 50 60Hz or 15 30 VDC 30 watts maximum Operating Temperature 14 F to 140 F 10 C to 60 C Storage 40 F to 158 F 40 C to 70 C Display 320 x 240 pixel QVGA backlit LCD UV resistant Simultaneous Rate and Total 10 digit maximum exponent to E 32 Decimal location configurable to 10 places Display Languages English Spanish French or German selectable Keypad Five button positive action tactile switch keypad Security Programmable master password and individual configuration passwords Display Volume Units Independently configurable Rate and Total display units in U S Gallons ounces barrels US liquid barrels US oil cubic feet acre feet Imperial British gallons liter cubic meter or user defined custom units Rate display in feet or meters per second Display Time Units Seconds minutes hours days Display Output Update Time Selectable 0 25 0 50 1 0 default 2 5 5 0 seconds Flow Rate Display Averaging Selectable 0 50 1 0 2 5 5 0 default 10 0 seconds Data Outputs e Isolated 4 20 mA output fully configurable invertible
9. output fully configurable e Computer connection via RS 232 RS 485 USB Ethernet Permits remote access and control of all functions including real time display system configuration data logging remote data capture and process control functions Software permits remote internet access through local network set up Petrochemical e Any sound conducting liquid e Process control via three independently configurable 10 amp form C relays Configure to flow rate for high low range rate alarm or to flow total for either manual trigger batch operations or flow triggered batch operations 1 of 4 TDS 85000 077 rev 06132008 SONIC PRO Ultrasonic Flow Meters Engineering and lechnical Data Installation Fluid Requirements The Sonic Pro series Hybrid Ultrasonic Flow Meters can measure fluid flow in virtually any fluid in which sound waves can travel The Sonic Pro meters are considered hybrid because they can measure fluid flow using either the Doppler or Transit Time methods The Sonic Pro ultrasonic sound transducers are clamped to the outside of the pipe wall and include no moving parts This method of flow measurement is safe non intrusive and very easy to service The Doppler measurement method requires particles be present in the flow stream to reflect the sound waves The meter may be operated in the Doppler mode when the fluid contains 0 02 to 15 200 to 150 000 ppm of particles The Transit Time measuring method req
10. ters Engineering and lechnical Data Specifications General Operation Measuring Principle Hybrid User selectable Doppler or Transit Time operating modes Fluid Types Virtually any acoustically conductive fluid Transit time mode from 0 to 10 0 to 100 000 ppm particulate Doppler mode from 0 02 to 15 200 to 150 000 ppm of 50 micron particulate Fluid Velocity Range 0 25 to 30 feet per second 0 07 to 9 meters per second Nominal Pipe Sizes 2 0 inch 100 inch 63mm to 2500mm Pipe Liner Materials Most plastic liners Pipe Materials Most metal and plastic pipes Pipe Material Pipe Size Ranges 2 to 100 63mm to 2500mm 2 to 100 63mm to 2500mm 2 to 100 63mm to 2500mm 2 to 100 63mm to 2500mm Max Pipe Wall 500 13mm 500 500 500 500 2 00 2 00 1 00 500 1 2 00 500 1 500 500 Brass Naval 13mm O O O O D FRP fiberglass Reinforced Plastic To 3 3 13mm 13m 50m Iron cast lron ductile 2 to 100 2 to 100 2 to 100 2 to 100 63mm to 2500mm 63mm to 2500mm 63mm to 2500mm 63mm to 2500mm 3 x gt x Polyethylene HDPE Polyethylene LDPE 3 En oO 3 3 N On 3 3 Polypropylene PVC CPVC 304 Stainless Steel 304L Stainless Steel 316 Stainless Steel Steel 1 carbon hard
11. uires relatively clean fluid to enable the sound waves to complete their circuit The meter may be operated in the Transit Time mode when the fluid contains 0 to 10 0 to 100 000 ppm of particles To allow for changes in the fluid s particle count the Sonic Pro monitors the signal gain and employs an Automatic Gain Control AGC algorithm that periodically adjusts the gain maintain the optimum power level The speed at which sound travels in the fluid must be known The factory will configure the meter for a known fluid during the initial configuration The Sonic Pro model S3c includes a 5 button user interface and remote PC software that can be used to configure the meter Many common fluids are listed in the software and can be selected directly from the menu Provided the speed of sound in the fluid is known custom unknown fluids can be input manually by the user A list of various fluids and their sound speeds are provided in the user manual Flow Stream Requirements The Sonic Pro s sound wave beam is only affected by fluid that actually passes through the beam and therefore the meter will not measure accurately if the fluid velocity is not consistent across the entire pipe diameter Flow disturbances such as pumps elbows tees and valves in the flow stream can cause swirl patterns and vortices that will affect the measurement Install the transducers on a straight run of pipe as far as possible from any disturbances The distance r