PS1 Installation Instructions and User Guide (694 KB PDF)

image

Contents

1. OutBack breakers are warranted for 10 years and are available in 10 15 20 30 and 50 amp single breakers OutBack offers ganged dual 10 15 20 25 and 30 amp breakers for 240VAC loads PSX 240 must be included in the system for 240 VAC loads Dual breakers require two spaces in the PS1 s AC sub panel EXTERNAL SUB PANELS e An external sub panel must have the branch circuit rated breakers installed e The second 50 amp breaker from the left in the PS1 breaker panel the breaker furthest to the right of the AC Bypass Mechanism will provide an AC disconnect for the external sub panel at the source the PS1 Run the external sub panel off of the AC Out Hot AC Neutral and Ground bus bars AC INPUT e The dwelling s main service entrance must have a 60 amp branch circuit rated breaker feeding the AC In Hot terminal bus bar of the PS1 e There must also be neutral and ground connections Figure 9 between the PS1 and the main service panel Connect the neutral wire to the AC Neutral bus bar and the ground wire to the Ground bus bar e The third 50 amp breaker from the left directly under the words AC GRID in Figure 7 provides a local AC input disconnect at the PS1 LIGHTNING ARRESTORS e The PS1 includes two lightning arrestors one for the AC Input and one for the DC system e There are three 1 2 knockouts on the bottom of the PS1 that can be used to fit these arrestors see Figure 7 e The installer can mount the l
2. Code NEC Handbook Photovoltaic Power Systems is helpful 35 OutBack Power Systems Five Year Limited Warranty OutBack Power Systems Inc warrants that the PS1 2500 and the PS1 3000 it manufactures will be free from defects in materials and workmanship for a period of five 5 years subject to the conditions set forth below The limited warranty is extended to the original user and is transferable The limited warranty term begins on the date of invoice to the original user of the product The limited warranty does not apply to any product or part thereof damaged by a alteration or disassembly b accident or abuse c corrosion d lightning e reverse polarity f repair or service provided by an unauthorized repair facility or g operation or installation contrary to instructions pertaining to the product OutBack Power Systems liability for any defective product or any part thereof shall be limited to the repair or replacement of the product at OutBack Power Systems discretion OutBack Power Systems does not warrant or guarantee the workmanship performed by any person or firm installing its products THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE OR JURISDICTION TO JURISDICTION OUTBACK POWER SYSTEMS RESPONSIBILITY FOR MALFUNCTIONS AND DEFECTS IN HARDWARE IS LIMITED TO REPAIR AND REPLACEMENT AS SET FORTH IN THIS LIMITED WARRANTY STATEMENT ALL
3. EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD SET FORTH ABOVE AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER SUCH PERIOD SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU OUTBACK POWER SYSTEMS DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES SET FORTH IN THIS LIMITED WARRANTY STATEMENT OR LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION ANY LIABILITY FOR PRODUCTS NOT BEING AVAILABLE FOR USE SOME STATES OR JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU 36 During the five year period beginning on the invoice date OutBack Power Systems will repair or replace products covered under this limited warranty that are returned to OutBack Power Systems facility or to an OutBack Power Systems authorized repair facility or that are repaired on site by an OutBack Power Systems authorized repair technician To request limited warranty service you must contact OutBack Power Systems at 360 435 6030 within the limited warranty period If limited warranty service is required OutBack Power Systems will issue a Return Material Authori
4. Note A combiner is essentially a sub panel for the solar array Each string a string is a group of PV panels wired in series only requires a circuit breaker inside a combiner OutBack OBPY series circuit breakers are available for the PSI s integral PV combiner For those users who already have external PV combiners these combiners can continue to be used without the additional cost of OutBack PV array breakers inside the PS1 e Each PV breaker can be connected to a 48V 60V or 72V nominal PV string Note Every string must be the same nominal voltage e The PV breakers must be the correct amperage as given by the PV panel manufacturer do not undersize Each breaker must be equal in ampacity to the UL listed series fuse rating e All wiring to and from the PS1 cabinet must use rain tight or wet location conduit and connector fittings e When using the PS1 s PV combiner area located to the left of the OBDC GFP 2 breaker connect the supplied fingered bus to the PV Positive connection 1 in Figure 10 See the next section Using the PS1 s Integral Combiner Area for more complete instructions e There is space inside the PS1 for eight OutBack OBPV Series breakers available in 4 6 8 9 10 15 20 and 30 amps current ratings See Figure 11 showing the hook up of the PV panels directly to the PS1 s PV combiner area e If an external PV combiner is used connect the PV positive wire to the OBDC GFP 2 s left stud using a
5. Solar modules can produce hazardous voltages when exposed to light Cover them with opaque material before servicing any connected equipment 6 The PS1 must be properly grounded for safe operation 7 Do not disassemble the PS1 refer all servicing to qualified service personnel Incorrect re assembly risks electric shock or fire REGULATORY COMPLIANCE The PS1 has been ETL tested to UL standard 1741 and is also CSA certified to C22 2 No 107 1 01 ETL is a Nationally Recognized Testing Laboratory NRTL FACTORS AFFECTING PS1 PERFORMANCE A correctly installed PS1 will perform in accordance with the power available to it whether from a grid or a renewable source This performance is affected by PV array factors and certain inefficiencies in the equipment and wiring PV array factors include Real world conditions rarely meet ideal factory conditions used to rate panels Typically an array will produce 60 70 of its rated output High temperatures reduce an array s efficiency especially roof mounted systems The array s orientation the angle of the sun shade smog and the amount of daily sunlight all affect results GENERAL MAINTENANCE Occasionally inspect the PS1 for loose wires and connections When replacing batteries in a PS1 BE Battery Enclosure OutBack recommends using four of one of the following types of batteries Do not mix battery types gt Trojan 31 AGM or 27 AGM gt MK 8A31 or 8A27 AGM or 8G3
6. is also the tie point for the MX60 s battery positive connection There are no over current protective devices between this tie point and battery positive Do not hook any other circuits to this tie point without proper over current protection No 4 Battery Negative Connection Connect the battery negative cable to the left side of the battery negative connection the DC shunt The DC shunt has voltage sense connection points for those installations desiring an amp hour meter In normal use there will be almost no measurable current flowing to or from the battery The only time an amp hour meter would register is during an outage when the batteries are being drained or during recharging Torque this connection to the DC Shunt specification in Table 1 28 AC WIRING INSTRUCTIONS No 5 a AC Out Hot Bus b Integral Sub Panel 5a This AC OUT HOT bus bar is used to connect to the AC sub panel either internal or external Use 6AWG black THHN wire to connect from the PS1 s AC OUT HOT bus to the AC HOT IN bus of an external AC sub panel Longer wire runs will require an increase in the wire size per NEC and local code Use the torque specs on the label inside the PS1 see Figure 1 5b The PS1 s integral AC sub panel can house up to four branch circuit breakers for the loads backed up by the PS1 The PS1 includes one 15 amp and one 20 amp breaker and two more breaker slots for additional OutBack OBAC circuit breakers sold separ
7. now before the battery cables are installed Attach each RTS to the surface of the same battery any battery is acceptable e Use the three 21 cables supplied to make the three series interconnects see Figure 6 e With the FX battery breaker off see 4 in Figure 7 connect the 39 red cable with red ends to the top battery s PLUS terminal run the cable through the conduit and connect the other end to the DC Positive Bus in the PS1 see 3 Figure 10 using the hardware supplied and a 1 2 wrench and socket The battery cable lug must contact the bus bar e Wrap the bottom lug of the 49 black cable with black ends with several layers of electrical tape to prevent it from accidentally shorting out against the battery Connect the top end of this cable to the left side of the DC shunt inside the PS1 see Figure 10 location 4 Battery Negative Connection Run this cable through the conduit to the battery enclosure Carefully remove the tape from the bottom end of the battery negative cable and connect it to the battery negative post of the bottom battery Once it is connected the battery to PS1 system is fully connected e Make sure the cables look like Figure 6 as well as like the PS1 DC Wiring diagram see Figure 12 Note In an enclosure other than the PSI BE be sure the FX battery breaker is OFF Run each RTS from the PS1 to the battery bank before running the battery cables Attach each RTS to the same battery cell a
8. 1 4 ring terminal tighten to the GFP 2 torque specification in Table 1 See the Using the External PSPV Combiner Box section for more information and instructions if using OutBack s PSPV Combiner 25 Figure 11 s 1 DIN rail 4 OBDC GFP 2 PV Positive connection 2 box lug 5 wire connecting fingered bus to PV Positive connection 3 fingered bus USING THE PS1 s INTEGRAL PV COMBINER AREA Refer to Figure 11 e Remove the PS1 breaker cover by unscrewing the four Phillips head screws e Install the OBPV breakers to the DIN rail securing them with their yellow clips e On the PS1 breaker cover punch out the knockouts for the OBPV breakers and position the OBPV breakers so the PS1 breaker cover can be reinstalled e Locate the fingered bus box lug star washer and screw Attach the box lug to the fingered bus using the star washer and screw e Insert the fingered bus into the top of the PV breakers and tighten the PV breakers to the fingered bus using the AC and PV breakers torque specification in Table 1 26 e Runa wire from the box lug behind the DIN rail to the PV connection on the OBDC GFP 2 The wire must be capable of carrying the combined PV current per the NEC and local code A ring terminal not included with 1 4 hole must be used to connect the wire to the OBDC GFP 2 e Run the PV positive strings to these OBPV breakers and tighten to the AC and PV breakers torque specs in Table 1 USING T
9. ATION WILL BE ENTIRELY AT THE USER S RISK Date and Revision June 22 2006 Contact Information OutBack Power Systems 19009 62nd Ave NE Arlington WA 98223 Phone 360 435 6030 Fax 360 435 6019 www outbackpower com PS1 Grid Tie with Battery Backup Installation Instructions and User Guide 6 22 2006 Copyright 2006 OutBack Power Systems Inc Rev 1 0 Prlim 900 0048 1 Warranty Summary Dear OutBack Customer Thank you for your purchase of OutBack products We make every effort to assure our power conversion products will give you long and reliable service for your renewable energy system As with any manufactured device repairs might be needed due to damage inappropriate use or unintentional defect Please note the following guidelines regarding warranty service of OutBack products e Any and all warranty repairs must conform to the terms of the warranty e All OutBack equipment must be installed according to their accompanying instructions and manuals with approved over current protection in order to maintain their warranties e The customer must return the component s to OutBack securely packaged properly addressed and shipping paid We recommend insuring your package when shipping Packages that are not securely packaged can sustain additional damage not covered by the warranty or can void warranty repairs e There is no allowance or reimbursement for an installer s or user s labor or travel time required to
10. HE EXTERNAL PSPV COMBINER BOX The OutBack PSPV is an external rainproof combiner capable of connecting up to 12 strings using OBPV circuit breakers rated up to 150 VDC The wiring from the combiner to the PS1 must be large enough to keep voltage losses at a minimum The PSPV and the bus bars inside the PS1 will accept up to 1 0 wire If the run is long enough to require larger wire then it will need to be reduced at the point of termination Consult the MX60 manual for a good description of wire loss and trade offs See Figure 13 to view a diagram of PV hook up utilizing an external combiner box Array Example PS1 3000 Three 165 watt 24 volt nominal PV panels can be wired in series to produce a 72 volt nominal array 132 volts open circuit This string of three panels is equal to 495 watts You can safely put six of these strings into the PS1 3000 combiner area 6 X 495 2970 watts which is under the 3200 watt maximum for a PS1 3000 but not under the 2700 watt limit of the PS1 2500 There are eight PV breaker slots inside the PS1 but in this case you would only be using six of the slots for PV breakers 72 volt arrays can only be used where temperatures do not drop below 5 degrees Fahrenheit In colder climates it is suggested to use either a 60 volt array or a 48 volt array due to excessively high open circuit voltages during cold weather A 48 volt nominal array requires e 165 watt 24 volt nominal PV panels e wire two panels in se
11. Installing the MATE Remote Status Display 33 Operation 33 Power Usage 33 DC Ground Fault Detector Interrupter 34 Utility Connection and Inspection 35 Warranty 36 READ FIRST Please read pages 5 12 before installing the PS1 IMPORTANT READ AND SAVE THESE SAFETY INSTRUCTIONS This manual contains important instructions to follow during the installation and maintenance of the OutBack Power Systems PS1 Grid Tie with Battery Backup system 1 Read all instructions and cautionary markings on the PS1 the batteries and all appropriate sections of this installation and user manual as well as included manuals for other components before using the system 2 Install all components and wiring according to national and local electrical and building codes This includes but is not limited to submitting a plan to the local building department passing inspection and requiring a licensed electrician to do the work when mandated OutBack Power Systems cannot be responsible for system failure damages or injury resulting from improper installation of their products 3 Use only the recommended wire sizes or greater Be sure all wires are in good condition 4 Avoid damaging the PS1 or its components prior to or during installation Do not install damaged units 5 To reduce the risk of electrical shock disconnect AC DC and PV power from the PS1 before cleaning or doing any maintenance work Turning off the PS1 alone may not eliminate this risk
12. OutBack Power Systems PS1 Grid Tie with Battery Backup Installation Instructions and User Guide The OutBack Power Systems PS1 Grid Tie with Battery Backup is a complete power conversion center designed to meet UL CSA NEC and IEEE standards The PS1 is assembled from UL ETL and CSA listed components all factory wired and tested for integrated operation and performance Please read all the component manuals included with the PS1 OutBack Power Systems highly recommends the use of an OutBack MATE sold separately for monitoring and programming your PS1 system About OutBack Power Systems OutBack Power Systems is a leader in advanced energy conversion technology Our products include inverter chargers charge controllers auto transformers system communication components as well as battery temperature sensors breaker panels breakers and assembled systems Notice of Copyright OutBack Power Systems PSI Grid Tie with Battery Backup Installation Instructions and User Guide All rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING OUTBACK POWER SYSTEMS a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORM
13. UL1077 50 amp AC output breaker UL1077 50 amp AC input breaker UL1077 one 20 amp and one 15 amp branch circuit rated load circuit breakers UL489 and space for two more eight breaker spaces for use as an internal PV combiner OBDC GFP 2 ground fault protector PV disconnect amp MX60 battery disconnect triple ganged UL489 125 amp 125 VDC FX circuit breaker 25 000 AIC UL489 500 amp 50mv shunt for external meter monitoring external meter not included 10 AC IN HOT AC OUT HOT AC NEUTRAL GROUND and DC NEGATIVE terminal bus bars knockouts for side and bottom conduit entry lockable flip up circuit breaker cover 1 4 thick polycarbonate viewing window two RTS battery temperature sensors 50 foot CAT 5 cable for remote monitoring through the optional MATE or MATE2 AC and DC lightning arrestors fingered bus connector to combine PV strings 2 PS1 BE Battery Enclosure Note The PSI Battery Enclosure PS1 BE is sold separately from the PS1 Ventilated rainproof aluminum enclosure with the following equipment shelves to hold four group 27 or group 31 sealed required AGM or gel batteries placed on their side battery hold down straps 1 0 flexible MTW2 cable for battery positive battery negative and battery interconnects one 1 4 x 6 rigid conduit nipple and two waterproof TYPE 3R conduit hubs also called Myers hubs to connect the PS1 directly over the PS1 BE knockouts on top and each side for connecti
14. URES section of this manual For battery installation and maintenance read the battery manufacturer s instructions prior to installation and operation See the BATTERY SELECTION AND INSTALLATION section for more information All installations must comply with local and national electrical codes and standards If a remote or automatic generator start system is used disable the automatic starting circuit and or disconnect the generator from its starting battery to prevent starting during installation or servicing GROUNDING NOTICES This product s intended installation is as part of a permanently grounded electrical system per the National Electrical Code NEC The equipment ground on the PS1 is marked GROUND BUS and is located inside the PS1 s Wiring Compartment In the electrical system the AC Neutral conductor must be grounded to a single point only This bonding should already be present at the main service entrance panel The negative battery conductor must be grounded to only a single point in the system This bonding is already achieved through the pre wired OBDC GFP 2 inside the PS1 Never positive ground the PS1 LIST OF INCLUDED ITEMS 1 PS1 2500 or PS1 3000 Ventilated rainproof aluminum enclosure with the following equipment GTFX3048 PS1 2500 or the GVFX3648 PS1 3000 inverter charger MX60 PV MPPT charge controller HUB4 communications manager thermally actuated cooling fan 50 amp AC bypass breaker
15. X STRINGS OF 24V X 3 PANELS WIRED IN SERIES AGES Ene i es SIMPLIFIED SCHEMATIC AUN We 48VDC GRIDTIE SYSTEM i 1 SHOWING SELLBACK PATH A imal SUBPANEL ll a BREAKER BOX So AS CR a P Ta 1 ith 5 m N FB UTILITY MICROWAVE FRIDGE LIGHTS METER SPINS OR TV BACKWARDS Figure 14 Power Flow Diagram DC GROUND FAULT DETECTOR INTERRUPTER The OBDC GFP 2 device used in the PS1 to comply with section 690 5 of the NEC ANSI NFPA 70 meets the requirements of UL1741 sections 31 2 31 6 and 53 56 as verified by ETL This device recognizes current flowing in the ground connection ground fault and immediately disconnects the PV and MX60 circuits 34 UTILITY CONNECTION AND INSPECTION Utility companies are not always PV friendly You must work with your utility company to meet all of their demands on interconnecting with their system The federal government has mandated that the utilities must purchase your PV generated power but the utility companies set the rules Your utility company might require additional AC and battery disconnects between the PS1 and the meter Requiring PV disconnects and battery disconnects outside by the meter can be construed as unnecessary costs calling a professional installer to deal with the local utility company and its inspectors could be prudent Familiarity with Article 690 of the National Electrical
16. a system display and controller which increases the user s system options Please see the MATE User s Manual for more information on OutBack s website www outbackpower com manuals htm The MATE connects to the PS1 using non crossover CATS cable The PS1 comes with 50 feet of CATS hooked up and ready for connection to the MATE CATS cable up to 1000 feet from an outdoor installed PS1 to the MATE must be run in approved conduit Note Signal degradation can result if the CAT 5 cable is run in conduit with AC wiring or in other electronically noisy environments these can affect the maximum length the cable can run without incurring transmission errors OPERATION e To energize the PS1 turn on the FX battery breaker and the OBDC GFP 2 at the same time see Figure 7 e Next turn on the AC and PV breakers and set the AC bypass mechanism to normal e Within 30 seconds the PS1 will connect to the grid which will then power the back up load The PS1 will not charge or sell for five minutes due to UL regulations After five minutes the PS1 will charge the battery bank to ensure a fully charged battery should the grid fail This normally takes 1 2 hours e After charging the batteries the PS1 looks for any available excess renewable energy to power loads or sell to the grid e Until the grid fails and reconnects the PS1 will not use the grid to perform another charge The PS1 comes pre wired and programmed with pre set s
17. ately The installer must use 12AWG black THHN wire for the 20 amp breaker and 14AWG black THHN wire for 15 amp breakers Connect these internal AC sub panel breakers to the AC OUT HOT bus located within the PS1 Use the torque specs on the label inside the PS1 see Figure 1 for bus bar connections No 6 AC In Hot Bus From a 60 amp branch rated breaker the main service panel s hot conductor connects to the AC IN HOT bus bar This terminal bus bar is the point where current will flow back to the main service panel when selling excess power or flow from the main service entrance panel when buying Main service panels typically utilize stab in thermal circuit breakers The NEC allows only 80 load on these types of breakers This equates to 48 amps The PS1 has 50 amp hydraulic magnetic breakers that are rated for the full 50 amps of continuous duty Use 6AWG black THHN wire minimum for this connection For long wire runs refer to the NEC and local codes for the correct wire size Connect the AC Lightning Arrestor s black wire to this bus bar as well Use the torque specs on the label inside the PS1 see Figure 1 for bus bar connections No 7 AC Neutral Bus Connect the main service panel s neutral conductor here and from here to the external AC sub panel if present Use 6A WG white THHN wire for this connection or greater if required by a longer wire run If the PS1 s internal AC sub panel is used run wire from this bus bar to the
18. backed up loads Refer to the NEC and local codes for proper wire size Connect the white wire of the AC Lightning Arrestor to this bus bar as well Use the torque specs on the label inside the PS1 see Figure 1 for bus bar connections No 8 Ground Bus Connect the green or bare copper conductor from this terminal bus bar to the earth ground connection in the main service panel If an external AC sub panel is used connect a 29 conductor from this bus bar to the external AC sub panel If the PS1 s internal AC sub panel is used run wire from this bus bar to the backed up loads Refer to the NEC and local codes for the accurate wire size Connect the green wires of both the AC and DC Lighting Arrestors to this bus bar as well as the PV ground wire Use the torque specs on the label inside the PS1 see Figure 1 for bus bar connections No 9 GFCI Outlet Mounting Locations One or two GFCI outlets can be added to the sides of the PS1 Outdoor installations require IN USE covers to meet NEC ANSVNFPA 70 section 410 56 i Either the 15 amp or 20 amp circuit breaker can be used for the GFCI circuit 30 gt ce a lt a Figure 12 PS1 DC Wiring Diagram 31 HE BATTERY BO 32 Figure 13 PS1 DC Wiring Diagram with External PSPV Combiner Box INSTALLING THE MATE REMOTE STATUS DISPLAY The optional OutBack MATE is
19. bout one half way up Both the battery to battery and the battery bank to PSI connections should be done with 2 0 cables The cables must be run through the same conduit and should be run the shortest distance possible Connect the battery positive cable to the PS1 first The last battery cable connection should be to the negative post of the battery bank 17 Figure 5 FX Series Inverter Charger Wiring Compartment TESTING THE BATTERY INSTALLATION AC HOT OUT e With the batteries connected and all the breakers OFF switch the FX breaker ON to test the battery FX circuit e The green INVERTER light and one of the battery level lights on the FX Series Inverter Charger should illuminate Look through the viewing window to verify this refer to Figure 5 e Once this has been verified BATTERY MATE turn the FX battery breaker off INVERTER TEMP HUB e Install the cover on the PS1 ONOFF BE with the included four 10 ALN 32 x 7 16 pan head screws AUK and four nylon washers AC NEUTRAL OUT CHASSIS GROUND CHASSIS GROUND AC NEUTRALIN AC HOT IN 5 gt 5 r a XY i 2 a 5 Z SILY JANI g ER BATTERY STATUS INVERTER green light 18 Figure 6 Battery Enclosure Positive red battery cable Negative black battery cable P positive terminals N negative terminals I series interconnect cables 19 AC CONNECTIONS Local building codes might mandate only license
20. bs so the overall length is 8 3 4 end to end Remove the 1 3 4 diameter knockout on the bottom of the PS1 From the outside of the upper cabinet push one end of the conduit along with the Myers hub through the knockout hole Replace the locknut tightening it enough to stay attached but leave the hub loose until the battery enclosure is installed Hold a carpenter s level or carpenter s square to the lower sections of each side of the PS1 and draw pencil lines down the wall These will act as guides for lining up the PS1 BE Verify the studs location with the stud finder For mounting the PS1 BE under the PS1 cabinet Remove the 1 3 4 diameter knockout on the upper surface of the PS1 BE The PS1 BE will hang approximately 7 under the PS1 cabinet Confirm the conduit knockout is aimed upward Hold the PS1 BE to the wall and move it upward so the conduit slips through the PS1 BE s knockout Line up the PS1 BE with the pencil lines Check that the PS1 BE is level Hammer a 16d nail through one of the fastener openings on each side of the PS1 BE so it can temporarily hang on them checking again that the cabinet is level and square Drill pilot holes top middle and bottom for at least six or more 5 16 X 2 1 2 lag bolts using a 3 16 bit Install the lag bolts washers and nuts and tighten securely 15 e Remove the 16d finish nails if desired e Replace the locknut on the Myers hub in the PS1 BE Tig
21. d center having multi wire common neutral branch circuits connected Use a PSX 240 Auto Transformer if you have a 120 240 VAC load bank Please refer to the PSX 240 Auto Transformer Installation Manual available on line at http outbackpower com manuals htm for installations that require 120 240 VAC wiring 20 Figure 7 PS1 s Internal Breaker Panel AC BYPASS IMPORTANT SAFETY INFORMATION PS1 GRID TIE INVERTER OutBaek r in order to completely shut down this system tum off both of the AC b kors lett on UP right one SYSTEM Power SUDER DOWN AC GRID Inverter Disconnect and PV Array Disconnect bro hie w rn ol tho power a BOTH BREAKERS WP to the backed up AC load circuits PV DISCONNECT CAUTION HAZARDOUS AC amp DC VOLTAGES MAY STILL BE PRESENT INSIDE THIS ENCLOSURE GROUND FAULT WNERIER EVEN WHEN THE BREAKERS ARE IN THE OFF POSITION PROTECTION This device actuates 3 devicos peer BACKED UP AC LOADS PV ARRAY COMBINER 4 An extemal AC load sub panel These spaces ato provided to allow installation of options OBPY mame breakers to protect the individual sarias connected PY modules P1 PV Array Disconnect P2 DC GFP Detection System 1 2 Knockouts 1 AC Bypass Mechanism 2 AC Breakers AC Input and AC Sub Panel 3 OBDC GFP 2 PV Disconnect Ground Fault Detector MX60 Disconnect Lightning arrestors install 4 FX Battery Disconnect in knockouts 5 Integral PV Combiner Breaker Panel 21
22. d electricians handle the AC connections and hook ups of your PS1 OutBack Power Systems urges compliance with local regulations for both safety and legal reasons Insurance might not cover any damage or injury done to property or person as a result of an incorrect installation or one that has not passed inspection Before doing this part of the installation please refer back to the safety instructions at the beginning of this manual This section includes connecting the AC Output to a sub panel and the AC Input connections from the utility AC OUTPUT e This system requires a sub panel to service the backed up loads The PS1 s internal panel can act as an AC sub panel for up to four branch circuits see 2 in Figure 7 For more than four branch circuits a separate sub panel must be installed If the system is powering a 120 240 VAC load bank OutBack s PSX 240 Auto Transformer must be installed e Rectangular knockouts on either side of the PS1 can be removed to install GFCI outlets Either or both locations can be used Outdoor locations must have an IN USE raised cover over the GFCI This is required per NEC Code ANSVNFPA 70 section 410 56 i Use the two pre installed 15 amp and 20 amp circuit breakers to protect the GFCI outlets e The AC output of the PS1 is protected by a 50 amp 100 rated hydraulic magnetic circuit breaker W Warning To reduce the risk of fire do not connect the PS1 to both hot legs of a 120 240 VAC loa
23. disconnect service or reinstall the damaged component s e OutBack will ship the repaired or replacement component s prepaid to addresses in the continental United States where applicable Shipments outside the U S will be sent freight collect e In the event a product malfunction OutBack cannot bear any responsibility for consequential losses expenses or damage to other components e Please read the full warranty at the end of this manual for more information Scope The manual provides safety guidelines and installation information It does not provide information about specific brands of solar panels and supplies limited information on batteries TABLE OF CONTENTS Read First 5 Important Safety Instructions 5 Regulatory Compliance 5 Factors Affecting PS1 Performance 6 General Maintenance 6 Torque Requirements 7 Features 8 Battery Precautions 9 Additional Notices 10 Grounding Notices 10 List of Included Items 10 Additional Equipment Tools and Parts Required 11 Mounting the Enclosures 14 Battery Selection and Installation 16 Battery Selection 16 Suggested Batteries 16 PS1 BE Battery Installation 17 Testing the Battery Installation 18 AC Connections 20 AC Output 20 External Sub panels 22 AC Input 22 Lightning Arrestors 22 Internal PS1 Connections 25 PV Wiring Instructions 25 Using the PSI s Integral PV Combiner Area 26 Using the External PSPV Combiner Box 27 DC Wiring Instructions 28 AC Wiring Instructions 29
24. e location CAUTION To reduce risk of injury charge only deep cycle lead acid lead antimony lead calcium gel cell or absorbed glass mat type rechargeable batteries Other types of batteries may burst causing personal injury and damage Never charge a frozen battery PERSONAL PRECAUTIONS Someone should be within range of your voice to come to your aid if needed Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes Wear complete eye protection Avoid touching eyes while working near batteries Wash your hands with soap and warm water when done If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye flood eye with running cool water at once for at least 15 minutes and then get medical attention immediately Keep a supply of baking soda on hand to neutralize lead acid battery electrolyte NEVER smoke or allow a spark or flame in vicinity of a battery or generator Be extra cautious to reduce the risk of dropping a metal tool onto batteries It could short circuit the batteries or other electrical parts that may result in fire or explosion Remove personal metal items such as rings bracelets necklaces and watches when working with a battery A battery can produce a short circuit current high enough to weld a ring or the like to metal causing severe burns ADDITIONAL NOTICES For instructions on mounting see the MOUNTING THE ENCLOS
25. hten both lock nuts inside each cabinet until the conduit is secure BATTERY SELECTION AND INSTALLATION The PS1 requires a 48V battery bank with at least 100 amp hours 20 hour rate of battery capacity The battery bank capacity of a PS1 2500 should not exceed 700 amp hours and the PS1 3000 should not exceed 900 amp hours When using a battery enclosure other than the PS1 BE be sure the enclosure is vented if using vented batteries The positive and negative battery cables should run together and travel as short a distance as possible BATTERY SELECTION The PS1 BE is meant to use sealed gel or AGM batteries only OutBack Power Systems has worked with three battery manufactures to ensure the PS1 system will give the best battery backed grid tie inverter system performance Concorde MK and Trojan all make group 27 or group 31 AGM batteries that are ideal for just this application These manufactures are well known in the renewable energy RE industry A 48V nominal battery bank is required whether a PS1 BE is used or not Only use batteries built for RE applications Other types such as automobile batteries are not suitable OutBack Power Systems believes properly maintained batteries can last a good ten years in a PS1 application SUGGESTED BATTERIES e Trojan 31 AGM or 27 AGM e MK 8A31 or 8A27 AGM or 8G3 lor 8G27 Gel e Concorde PVX 1080T or PVX 1040T AGM The PS1 s battery voltage set point for selling power back to the gr
26. id is 52 VDC This means any excess RE beyond what is required to maintain the 52 VDC charge is sold The system s energy demands along with normal energy losses from the batteries will cause a drop in the battery voltage thus a small amount of energy is required to maintain the 52 VDC charge even when the battery is not supplying power to other loads OutBack testing with sealed AGM batteries for example shows it takes about 10 watts to keep four group 31 batteries at the sell voltage during sunlight hours Ten watts is a minor use of RE given the benefits of battery back up The PS1 BE comes with everything needed to install and hook up the batteries except the batteries themselves e four battery straps to secure the batteries e three 21 1 0 battery cables to connect the batteries in series e one 39 1 0 battery cable to connect the battery positive to the PS1 s DC Positive bus e one 49 1 0 battery cable to connect the battery negative to the PS1 s DC shunt negative bus 16 PS1 BE BATTERY INSTALLATION gt Batteries are a live power source Be cautious when connecting cables gt Refer to the Table 1 Torque Requirements for the DC battery DC shunt and DC Positive Bus connections e Install the sealed batteries on their sides with the PLUS positive terminal on the left side as shown in the Figure 6 e Secure the batteries with the battery straps e Run both Remote Temperature Sensors RTS through the conduit
27. ightning arrestors by removing two of the 1 2 knockouts removing the lock nut from each arrestor inserting the threaded end of the arrestor through the knockout and reinstalling and tightening the lock nut see Figure 8 Figure 8 locknut PS1 Lightning Arrestor Qe LAA Or use on Do I Maximum g RA 600 5 f si or REbtning Arrest iE Spring Texts 22 Note DC lightning arrestor is not shown Figure 9 PS1 AC Wiring Diagram OPTIONAL EXTERNAL AC SUB PANEL WIRING DIAGRAM om p02 0011 1 23 Figure 10 Internal PS1 Connections 1 PV Positive Connection 2 DC NegativeBus 3 DC Positive Bus 4 Battery Negative Connection 5a AC Out Hot Bus 5b Integral AC Sub Panel 6 AC In Hot Bus 7 AC Neutral Bus 8 Ground Bus 9 GFCI Outlet Mounting Locations 2 24 INTERNAL PS1 CONNECTIONS e No terminals or lugs are required for hook up of the AC wiring AC wiring must be copper wire and rated for 75 C or higher e Crimped and sealed copper ring terminal lugs with a 3 8 hole should be used to connect the battery cables to the DC terminals of this PS1 Soldered cable lugs are also acceptable e Wires and lugs are required for hooking up the PV wiring PV WIRING INSTRUCTIONS Refer to Figure 10 No 1 PV Positive Connection e This is a 1 4 stud on the lower left of the OBDC GFP 2 for connecting the PV positive from the internal or external combiner
28. is is a single phase system with a sine wave output e The PS1 is approved for outdoor mounting TYPE 3R only in the vertical position All wiring to and from the PS1 enclosures must be suitable for rain tight or wet locations in compliance with UL514B The conduit hub connecting to the PS1 must have a TYPE 3R waterproof rating e The PSI includes one FX Inverter Charger one MX60 Charge Controller and accommodates two weatherproof GFCIs e PV panels up to 2700 W for PS1 2500 or 3200 W for PS1 3000 connect to the PS1 e When the grid is connected the PS1 can provide power to the backed up loads and sell power to the utility When the grid fails the PS1 will power backed up loads utilizing battery power e Mounting holes are 16 apart to secure to standardized stud spacing e OutBack pre wires the PS1 to save onsite installation time materials and difficulties BATTERY PRECAUTIONS WARNING WORKING IN THE VICINITY OF LEAD ACID BATTERIES IS DANGEROUS NON SEALED BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION Provide ventilation to the outdoors from the battery compartment The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas in pockets at the top of the enclosure Vent the battery compartment from the highest point if using a battery enclosure other than the PSI BE A sloped lid can be used to direct the flow of hydrogen to the vent opening at the highest possibl
29. lor 8G27 Gel gt Concorde PVX 1080T or PVX 1040T both AGM type Refer to your local regulations for battery disposal requirements TORQUE REQUIREMENTS CONNECTION TORQUE IN POUND MEASURES AC and PV breakers to 22 inch lbs 2 48 Nm GFP 2 assembly to 30 inch lbs 3 39 Nm DC shunt to 10 foot Ibs 13 6 Nm DC battery to 10 foot Ibs 13 6 Nm connections DC Positive Bus to 10 foot lbs 13 6 Nm Terminal Bus Bars See note below Table Torques for Installation Note The terminal bus bars have different torque requirements depending on hole and wire sizes refer to the label attached to the inside of the wiring compartment see Figure I for label location CONNECTION TORQUE IN POUND MEASURES FX s DC Terminals to 5 foot lbs 6 77 Nm FX s AC Terminals to 30 inch Ibs 3 38 Nm FX battery breaker to 45 inch Ibs 5 08 Nm MX60 s PV and to 35 inch lbs 3 95 Nm Battery Terminals MX60 s Ground Lug to 35 inch lbs 3 95 Nm Table 2 Additional Torques for Maintenance E fy piewe Torque value label for Terminal Bus Bars Figure 2 PS1 as seen through its metal enclosure A upper enclosure PS1 B battery enclosure PS1 BE C conduit D FX Series Inverter Charger E MX60 Charge Controller F breaker panel G battery bank H GFCI breaker and weatherproof cover supplied by installer I PS1 s wiring compartment FEATURES e Th
30. lthough the PS1 is rainproof install the system under an overhang if possible to minimize rain exposure e Mount the system to posts or wall studs as far off the ground as is practical to see the viewing window The combined height of the PS1 and the PS1 BE is about 67 1 2 They are connected with a six inch section of conduit and two Myers hubs which when threaded add about seven inches to the overall height approximately 74 1 2 Use this as your working height when locating and mounting the sections one over the other A person 5 10 tall can comfortably read the viewing window if the PS1 BE is about five inches off the ground e The PS1 BE can be mounted next to the PS1 with modified cable length Additional PS1 BE s can be installed side by side using waterproof conduit Note If the cabinets are mounted side by side they might require more or less than the included six inches of conduit to connect them depending on their proximity to each other e Install the batteries after installing the PS1 BE e The PS1 and the PS1 BE each mount sixteen inches on center This allows for overlapping mounting flanges when adding additional PS1 BEs See flange mounting detail in Figure 4 Figure 4 WASHER CT MOUNTING FLANGE 5 MOUNTING FLANGE E SHEATHING BOLT STUD 14 After establishing the height and placement use the stud finder to locate the wall studs and mou
31. nt the PS1 first This cabinet weighs approximately 107 pounds and OutBack Power Systems strongly recommends two people handle its installation Note Use at least six 5 16 x 2 1 2 lag bolts and flat washers to secure both the PS1 and PS1 BE to the wall studs OutBack Power Systems cannot be responsible for damage done to an improperly secured system The PS1 has 16 openings for fasteners to secure it to a wall Determine the location of two of these on the same level and hammer two 16d finish nails at least 2 1 2 into the wall studs Check that they are level Carefully lift and temporarily hang the PS1 on these nails and verify the PS1 is level Drill pilot holes top middle and bottom for six or more 5 16 X 2 1 2 lag bolts using a 3 16 bit Install the lag bolts washers and nuts and tighten securely The 16d finish nails can be removed if desired For battery enclosures other than the PS1 BE connect the battery enclosure to the PS1 at this time with approved conduit for this installation do not install and connect the battery bank yet Note OutBack does not recommend installing the PS1 without some form of battery enclosure connected with conduit The following installation instructions apply to the PS1 BE The PS1 BE weighs approximately 29 pounds and is more easily installed by two people Install both Myers hubs on the six inch conduit and remove the locknuts from the outside ends Tighten both Myers hu
32. on to the PS1 or additional PS1 BEs lockable front cover plate Note Each PS1 BE stores 4800 watt hours of power when using group 31 size batteries and slightly less for group 27 size batteries ADDITIONAL EQUIPMENT TOOLS AND PARTS REQUIRED Equipment 48 72VDC nominal PV array up to 2700 W for the PS1 2500 and 3200 W for the PS1 3000 PV combiner if not using the integral combiner slots in the PS1 one OBPV breaker for every PV string when using the integral PV combiner mounts and wiring for the PV array 48V nominal battery bank lockable and visible AC disconnect not an NEC or UL requirement but may be required by the utility company Note In accordance with the National Electrical Code ANSI NFPA 7 a 60 amp branch circuit rated breaker offering AC branch circuit over current protection for the PSI s AC input must be used in the main service entrance panel 11 gt Your utility might require a separate AC input meter for monitoring power production gt To fully monitor PV production sold to the grid and sent downstream to house loads install two separate meters one on the AC Input to the PS1 and one on the AC Output to the PS1 gt Install a Form 12S meter to monitor all power produced A Form 12 S meter can be used for Green Tag programs See the setup at www outbackpower com technicalnotes htm Tools Required for Installation flathead screwdriver torque measuring recommended Phillips scre
33. ries to yield a 48V 330 watt string e eight paralleled string arrays 2640 watts 48V nominal A 60 volt nominal array requires e 125 watt 12 volt nominal PV panels e wire five panels in series to yield a 60V 625 watt string e five paralleled string arrays 3125 watts 60V nominal Any variety of arrays can be constructed depending on your power needs but an array should not exceed the maximum wattage of the PS1 and the nominal panel voltage should be between 48V and 72V 27 DC WIRING INSTRUCTIONS No 2 DC Negative bus Connect all PV negative string conductors or the combined PV negative conductor to this bus bar Also connect the black wire of the DC lightning arrestor to this bus bar follow ing the specifications found on the torque label inside the PS1 s wiring compartment see Figure 1 No 3 DC Positive bus Connect the positive battery cable and the ring terminal of the DC lightning arrestor to this bus bar using the stainless steel bolt nut flat washers and lock washer included on this bus Connect the hardware and cable lugs as shown in the diagram below and tighten to the DC Positive Bus torque specification see Table 1 using the 1 2 wrench and ratchet The battery cable lug should contact the bus bar with the ring terminal directly on top of it CI Nut Lock Washer Flat Washer e DC Positive Bus Battery Lug ina aia eens ae Lightning Arrestor Lug Flat Washer Bolt This
34. wdriver torque measuring recommended ratchet torque measuring recommended with 1 2 and 9 16 attachments drill and 3 16 bit hammer 1 2 wrench wire stripper stud finder carpenter s level Additional Parts Required e four 16d finish nails e six or more 5 16 X 2 1 2 lag bolts per PS1 and PS1 BE with 5 16 washers and nuts for each lag bolt e one 1 4 ring terminal to connect the PV positive wire to the OBDC GFP 2 inside the PS1 ring terminal must fit the gauge of the PV positive wire 12 Figure 3 Note The center of the viewing window is 5 2 from the bottom of the PS1 BE PS1 3000 utvsack 5 Outs dpe PS1 2500 VIEWING WINDOW COVER PLATE EACH SIDE TO ALLOW FOR GCI INSTALLATION LS75 L09 KNOCK OUTS EQTH SIDES FOR 3 4 amp 1 CONDUIT T gt 11 4 X 6 CONDUIT NIPPLE e a AND VATER PROOF HJES SUPPLIED WITH P31 BE 175 KNOCK DUTY BOTH SIDES FIR 14 CONDUIT KNOCKOUTS ee oO ATTACH pues FORCED AIR INLET FOR UPPER CABINET ON BOTTOM SURFACE AND ON BACK OUTLET ON BACK CONVECTION AIR COOLING HOLES FOR PS1 BE ON BACK BOTH CABINETS ARE ALUMINUM TYPE 3R CRAINPROOF gt 13 MOUNTING THE ENCLOSURES Consider the following before locating and mounting your PS1 e Avoid exposure to the sun The system will be running in a very high ambient temperature condition and full sunlight reduces its power output e A
35. ystem and battery voltages The optional OutBack MATE allows user monitoring of the system and changing of set points if desired The PS1 system will not draw power from the utility at night to recharge the batteries Power for backed up load circuits is provided by the utility when solar power is not available and from batteries during grid failure The only time the PS1 will use utility power to recharge batteries is after an outage directly after the initial power up or if DC loads connected directly to the battery bank require more power than the PV can provide This insures the batteries are fully charged in case there is a grid failure POWER USAGE Figure 14 displays a grid tie system using a PS1 Although the system s MX60 might show the system producing power this does not mean there is available power to sell back to the utility company 33 e DC power from the PV array passes through the MX60 where it s transformed from higher voltage lower current to battery voltage higher current e The MX60 recharges the batteries as needed e Once the batteries are recharged the power from the MX60 will go directly to the FX Series Inverter Charger which will convert the DC power to AC e Power from the FX will feed designated loads through the sub panel e Any excess power not needed by loads or batteries is sold back to the utility COMBINER PHOTOVOLTAIC ARRAY IN A 48V SYSTEM CAN BE WIRED FOR 48V OR 72V NOMINAL VOLTAGE SHOWN IS SI
36. zation RMA Number Mark the outside of the package with the RMA number and include a copy of the purchase invoice in the package You must ship the products back to OutBack Power Systems in their original or equivalent packaging prepay shipping charges and insure the shipment or accept the risk of loss or damage during shipment OutBack Power Systems will ship the repaired or replacement products to you freight prepaid if you use an address in the continental United States where applicable Shipments to other locations will be made freight collect 37

Download Pdf Manuals

image

Related Search

Related Contents

GUIDE UNAC N. 2 POUR L`INSTALLATION DES  Manual - G  manuale utente 0893  Dell Force10 E1200i Installation Manual  Apostila Navioonline – Editada  Actes de l`Atelier « EIAH et situations de handicap - LIRIS  Sony VPL-SC50U User's Manual  User Manual / Installation Guide Model No. ITR  取扱説明書  X-Analysis manuel d`utilisateur  