Home
EKI-2541M/SC EKI-2541S/SC User Manual
Contents
1. 2 1 1 2 Dual Power InpUt 2 1 1 3 Flexible Mounting 2 1 1 4 Advanced Protection 2 1 1 5 Wide Operating Temperature 2 1 1 6 Easy Troubleshootind 2 2 aa 6 k eee eee ee ee ene ene mee een ene 3 1 3 Specification cc csscetan vas bareauciue cca ceytane Soucksaatade duces 4 1A Packing HISUxccssscaniniiransenrneeetoran atau 6 1 5 Safety Precaution civics svete vane svrnacecststuadetevededvauaents 6 Chapter 2 Installation ceeeceeeeeeeeeee eee 8 21 CED GICAONS ise tiia eri tesa 8 Table 2 1 EKI 2541M S LED Definition 8 22 DIPSSWIHGH cctvvec 2s hicccccs nae seca vans acess ane 9 Table 2 2 EKI 2541M S DIP Switch Definition 9 2 3 Dimensions units MM 10 Figure 2 1 Front View of EKI 2541M S 10 Figure 2 2 Side View of EKI 2541M S 11 Figure 2 3 Rear View of EKI 2541M S 12 Figure 2 4 Top View of EKI 2541M S 13 ZA MONING e r E 14 2 4 1 Wall mounting sceescconssdviiicciberiewedeewcosdedey 14 Figure 2 5 Combine the Metal Mounting Kit 14 2 4 2 DIN rail Mountind 15 Figure 2 6 Installation to DIN r
2. 2 3 W EKI 2541S 2 x Unregulated 12 48 Voc 1 Relay Output 37 x 140 x 95 mm IP30 Metal shell with solid mounting kits DIN rail Wall 4000 Voc 3000 Voc Present 10 60 C EKI 2541M 2541S 40 75 C EKI 2541MI2541SI 5 95 non condensing Storage Temperature 40 85 C Certifications Safety UL 60950 1 CAN CSA C22 2 No 60950 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 1 1 12 EN61000 6 2 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Chapter 1 4 Packing List 1 x EKI 2541M or EKI 2541S Industrial Ethernet to Fiber Optic Converter 1 x eAutomation Industrial Communication CD ROM with software and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2541M 2541S Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input EKI 2541M amp 2541S User Manual 6 CHAPTER Installation Sections include e LED Indicators e Dimensions e Mounting e Network Connection e Power Connection Chapter 2 Installation In this chapter you will be given an overview of the EKI 2541M 2541S hardware installation procedures 2 1 LED Indicators There are few LEDs display the power status and network status located on the front panel
3. Wall 2 4 1 Wall mounting EKI 2541M 2541S can be wall mounted by using the included mounting kit Then hang on the EKI 2541M 2541S to the nails on the wall First use the screws included in the package to combine the EKI 2541M 2541S and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below Figure 2 5 Combine the Metal Mounting Kit EKI 2541M amp 2541S User Manual 14 2 4 2 DIN rail Mounting You can also mount EKI 2541M 2541S on a standard DIN rail by below steps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 2541M 2541S to the DIN rail with angle of inclination See figure 2 6 Figure 2 6 Installation to DIN rail Step 1 15 Chapter2 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 EKI 2541M amp 2541S User Manual 16 2 5 Network Connection e Twisted pair segment can use unshielded twisted pair UTP or shielded twisted pair STP cabling The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long e Fiber segment using single mode connector type must use 9 125um si
4. Fail help you diagnose immediately EKI 2541M amp 2541S User Manual 2 1 2 Features Provides 1 x 10 100Mbps Ethernet ports with RJ 45 connector Provides 1 x SC multi mode amp single mode fiber connector Supports full nalf duplex flow control Supports store amp forward transmission supports auto negotiation Supports MDI MDI X auto crossover Provides surge protection EFT 3 000 Vpc for power line Supports 4 000 Vpc ESD protection for Ethernet Supports 12 48 Vpc power input Provides flexible mounting DIN rail Wall Mounting Supports operating temperatures from 40 75 C wide operating temperature model or 10 60 C standard model 3 Chapter 1 3 Specification Communications Compatibility LAN Transmission Distance Transmission Speed Interface Connectors LED Indicators Power Current Overload Protection Power Consumption Power Input Fault Output Mechanism Dimensions WxHxD Enclosure Mounting Protection ESD Ethernet Surge EFT for power Reverse Polarity Environment Operating Temperature Operating Humidity EKI 2541M amp 2541S User Manual IEEE 802 3 802 3u 802 3x 10 100Base TX Multi mode Fiber Up to 2km Single mode Fiber Up to 30km Up to 100 Mbps 1 x RJ 45 1 x SC type fiber connector 6 pin removable screw terminal power amp relay Unit P1 P2 P Fail Ethernet 10 100M LNK ACT Fiber HDX FDX LNK ACT 0 9A 12Vpc 25 2 7 W EKI 254 1M
5. EKI 2541M SC Ethernet to Multi mode SC Type Fiber Optic Converter EKI 2541S SC Ethernet to Single mode SC Type Fiber Optic Converter User Manual Copyright The documentation and the software included with this product are copyrighted 2007 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Part No 1st Edition Printed in China April 2007 EKI 2541M amp 2541S User Manual ii Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of purchase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel au
6. LED Indicators The switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying If the power indicator does not light up when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If user still cannot resolve the problem contact the local dealer for assistance If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit please check your system s Ethernet devices configuration or status EKI 2541M amp 2541S User Manual 20 A Pin Assignment amp Wiring APPENDIX Appendix A Pin Assignment amp Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Pint lt _ Pin8 Figure A 2 EIA TIA 568B Pint 4 Pin8 Figure A 3 EIA TIA 568A EKI 2541M amp 2541S User Manual 22 aA A Ww N oN A White Orange Orange White Green Blue White Blue Green White Brown Brown 1 White Green A e Ww N co A Green White Orange Blue White Blue Orange White Brown Brown
7. Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the user s manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 40 C 40 F OR ABOVE 85 C 185 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components EKI 2541M amp 2541S User Manual vi Contents Chapter 1 OverVvieW 2 Vet Introductionis lI el eae See 2 1 1 1 Fast Fiber Converters Module
8. ail Step 1 15 Figure 2 7 Installation to DIN rail Step 2 16 2 5 Network Connection 17 2 6 Power Connection 17 Figure 2 8 Pin Assignment of the Power Connector 17 Chapter3 Troubleshooting 20 Appendix A Pin Assignment amp Wiring 22 Figure A 1 RJ 45 Pin Assignment 22 Figure A 2 EIA TIA 568B EK 22 Figure A 3 EIA TIA 5684A ee 22 vii Contents EKI 2541M amp 2541S User Manual viii CHAPTER Overview Sections include e Introduction e Features e Specifications e Packing List e Safety Precaution Chapter1 Overview 1 1 Introduction The EKI 2541M 2541S is a cost effective solution for the converting between 10 100Base TX and 100Base FX cabling it allows you to extend the cabling distance of your 100Base FX network up to 2 kilometers for multi mode fiber or 30 kilometers for single mode fiber The Fast Fiber Converter module gives you the option to choose from the most popular fiber cabling connectors SC multi mode and single mode connector 1 1 1 Fast Fiber Converters Module The EKI 2541M 2541S provides you with one Fiber connector for your fiber optic cable and one Ethernet RJ 45 port Auto MDI MDIX for your 100Base TX copper cable connection There are four DIP switches to set the operation mode for UTP F
9. eed additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc Acomplete description of the problem The exact wording of any error messages EKI 2541M amp 2541S User Manual iv Safety Instructions 1 2 3 an 10 11 12 13 14 15 Read these safety instructions carefully Keep this User s Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage
10. for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer iii Declaration of Conformity CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recommend the use of CE compliant industrial enclosure products FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site at www advantech com support where you can find the latest information about the product Step 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you n
11. iber ports and Link Fault Pass Through function 1 1 2 Dual Power Input EKI 2541M 2541S redundant power input design is with power reserve protection to prevent the switch device broken by wrong power wiring When one of power input is fail P Fail LED will turn on and send an alarm through a relay output for notifying user 1 1 3 Flexible Mounting EKI 2541M 2541S is extremely compact 37 x 140 x 95 mm and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment 1 1 4 Advanced Protection EKI 2541M 2541S supports up to 3 000 VDC surge protection for power line and also supports 4000V ESD for Ethernet ports With these 2 strong protections it can secure equipment against unregulated voltage and make systems safer and more reliable Further EKI 2541M 2541S provides currency overload protection with a resettable fuse to ensure that the device component wont be damaged by overload current 1 1 5 Wide Operating Temperature The operating temperature of the EKI 2541M 2541S is between 40 75 C wide operating temperature model or 10 60 C standard model With such a wide range you can use the EKI 2541M 2541S in some of the harshest industrial environments that exist 1 1 6 Easy Troubleshooting LED indicators make troubleshooting quick and easy The 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and P
12. ngle mode cable You can connect two devices in the distance of 30 kilometers in full duplex operation For half duplex operation the recommended maximum distance is 412 meters 1 352 ft e Fiber segment using multi mode connector type must use 50 or 62 5 125 u m multi mode fiber cable You can connect two devices up to a 2 kilometer 6 562 ft distance 2 6 Power Connection The EKI 2541M 2541S supports dual 12 48 Vpc power inputs and power fail relay output PWR2 1A 12V PWR1 LILIILIII V2 V2 LW V1 V1 12 48 voc P Fail Figure 2 8 Pin Assignment of the Power Connector You can connect an alarm indicator buzzer or other signaling equipment through the relay output The relay opens if power input 1 or 2 fails Open means if you connect relay output with an LED the light would be off 17 Chapter2 EKI 2541M amp 2541S User Manual 18 3 Troubleshooting CHAPTER Chapter 3 Troubleshooting 1 Power Input Verify that is using the right power cord adapter 12 48 Vpc please don t use the power adaptor with DC output voltage higher than 48V or it will burn this converter down 2 Cable Select the proper UTP Fiber cable to construct your network The single mode converter must use single mode fiber cable Please check that you are using the right cable 3 DIP Switch Check the configuration DIP switch It must be setting in the same operation mode with the link partner 4 Diagnosing
13. of EKI 2541M 2541S each of them has its own specific meaning as below table Table 2 1 EKI 2541M S LED Definition LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 has failed P Fail Red Off Power input 1 and 2 are both functional or no power input On Ethernet port full duplex HDX FDX fiber port Yellow Off Ethernet port half duplex or not connect to network On Connected to network LNK ACT fiber port Green Flashing Networking is active Off Not connected to network On Link to 100M bps network 10 100M RJ 45 Yellow Off Link to 10M bps network On Connected to network LNK ACT RJ 45 Green Flashing Networking is active Off Not connected to network EKI 2541M amp 2541S User Manual 8 2 2 DIP Switch The DIP Switch is used to configure operation mode for LFP Link Fault Pass Through and operation mode for UTP Fiber port The default value of DIP switch is OFF Table 2 2 EKI 2541M S DIP Switch Definition S W No Status Description ON Enables Port Power Alarm OFF Disable Port Power Alarm ON Enables LFP 3 OFF Disables LFP ON 100Base FX Half mode OFF 100Base FX Full mode j ON Pure Converter mode 100TX to 100FX OFF Switch Converter mode LFP Link Fault Pass Through When LFP i
14. s enabled it allows UTP link failures to be reported to the fiber side and also allows Fiber link failures to be reported to the UTP side Therefore an LFP feature is provided in both UTP and Fiber side Pure Converter mode DIP Switch 4 When pure converter mode is enabled on it operates with the minimum latency The transmission flow does not wait until entire frame is ready but instead it forwards the received data immediately after the data being received And UTP port should be forced at 100M in this application When DIP Switch is in Switch Converter mode off the converter function is same as Switch Note Please dont change the DIP switch setting when UTP or fiber port is transmitting or receiving data It may cause some data error Besides if you change the DIP switch setting please power off the converter and power on again to make the setting effective 9 Chapter2 2 3 Dimensions units mm P1 P2 P Fail EEE HDX LNK FDX ACT P1 P2 P Fall EEE HDX LNK FDX ACT EKI 2541S Figure 2 1 Front View of EKI 2541M S EKI 2541M amp 2541S User Manual 10 Zou 140 00 eet 104 00 Figure 2 2 Side View of EKI 2541M S Chapter2 77 3 50 Figure 2 3 Rear View of EKI 2541M S EKI 2541M amp 2541S User Manual 12 Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2541M S 13 Chapter2 2 4 Mounting The EKI 2541M 2541S supports two mounting methods DIN rail amp
15. thorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible
Download Pdf Manuals
Related Search
Related Contents
le t em ps et l`es pa ce à tra v ers duqu éb ec culturelle d ire la Glacier Bay 51901-0004 Installation Guide SERVICE MANUAL Programmes de la deuxième année Manuel d`utilisation du logiciel de Programmation pour Tir Samsung WF-R1062 Uživatelská přiručka Adam Equipment SERIE AZextra - Balances industrie, laboratoire Canon Digital IXUS 310 HS Sony WM-FX195 User's Manual Copyright © All rights reserved.
Failed to retrieve file