1. Laboratory Balances PCE JS 100 User Manual Instruments PCE Americas Inc PCE Instruments UK Ltd 711 Commerce Way Units 12 13 Suite 8 Southpoint Business Park Jupiter Ensign way FL 33458 Hampshire Southampton USA United Kingdom SO31 4RF From outside US 1 From outside UK 44 Tel 561 320 9162 Tel 0 2380 98703 0 Fax 561 320 9176 Fax 0 2380 98703 9 info pce americas com info pce instruments com www pce instruments com english www pce instruments com Thank you for purchasing our pocket scale Please read all operating instructions carefully before use It may be necessary to calibrate the scale before the first use Precautions Please check the capacity Never load the scale with more than the maximal capacity Avoiding any exposure to extreme heat or cold your scale works better when operated at normal room temperature Always allow the scale to acclimate to normal room temperature for at least one hour before use Give your scale sufficient warm up time Usually 30 60 seconds before calibrating to give the internal components a chance to stabilize Keep your scale in a clean environment Dust dirt moisture vibration air currents and a close distance to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale Handle with care Gently apply all items to be weighed onto tray top Although this scale is designed to be quite durable try to avo
2. Remove the weight and press ON OFF to turn off the scale Finish 6 Ifa calibration error has occurred FAIL will be display Please repeat step 1 5 Counting Function With PCS key l 2 Press and hold PCS for two seconds then you will see 100 Press MODE CAL and you will see 25 50 75 100 Please select the number that you are willing to put as the sample number Then put the relevant amount of goods that you are going to count as the sample Then press PCS to confirm it Now you can put the goods that you want to count on the center of the platform and the LCD will show the actual number of the goods on the platform
3. id rough treatment as this may permanently damage the internal sensor Avoid shaking dropping or otherwise shocking the scale This is a precision instrument and must be handled with extreme care Only operate the scale on stable vibration free surface Specifications Capacity 100 g Resolution 0 01 g Linearity 0 02 g Repeatability 0 02 g Units g oz ct gn Tare Range tare full capacity Power 2xAAA batteries or 1x CR2032 battery etc Operation temp 10 30 C Function key introduction 1 Switsching Key ON OFF 2 Units Key MODE CAL 3 Tare Key TARE 4 Counting Key PCS Operation Please scale on a horizontal flat surface Press ON OF Wait until 0 0 is displayed stably Put the object s on the weighing platform Wait until the reading is displayed stably You can read it ee oe Press MODE CAL you can swich among the weighing units Tare weighing 1 Turn on the scale as described above 2 Place the tare item on the platform 3 Press TARE and wait until 0 0 is displayed 4 Add the net weight item Calibration 1 Turn on the scale 2 Press MODE CAL and hold on 2 seconds until CAL will be dislayed 3 Press MODE CAL again CAL will twinkle three times and the display reads 100 0 4 Place a 100 g weight in the middle of the platform Wait 3 to 4 seconds the LCD display reads PASS 5
Download Pdf Manuals
Related Search
Related Contents
manual técnico de instalación vers. 13 - ES Conclusions - Georgian College PDFをダウンロード 第1号(平成14年12月 Hardware User Guide Bta 040-581 RevB Serie CCM Safelex Cable Lockout - User Manual Copyright © All rights reserved.
Failed to retrieve file