A956WGOT-TBD User`s Manual (Hardware)

image

Contents

1. b For A8GT C100 200 300BS e Cut the ground wire from the core where it protrudes from both ends of the cable n rM wire Cut 28 e Peel the sheath with the length shown below at both ends of the cable and expose the shield braided wire for grounding GOT side Ferrite core GOT side ZCAT3035 1330 130 5 12 5 12 Within 360 40 40 _ Within 360 14 17 1 57 1 57 14 17 Dien ei c For A8GT C100 200 300EXSS 1 POINT The A8GT C100 200 300EXSS 1 is a combined product of the A8SGT EXCNB and A8GT C100 200 300BS e Cut the ground wire from the core where it protrudes from the A8GT EXCNB For A8GT EXCNB A8GT C100 130 Ferrite core 200 300BS side PLC sid rs 5 12 ZCAT3035 1330 l 1 f E Ground wire Unit mm inch e Cut the ground wires protruding from both ends of the A8GT C100 200 300BS with the length shown below e Peel the sheath with the length shown below at both ends and expose the shield braided wire for grounding For A8GT C100 200 300BS A8GT EXCNB side Ferrite core GOT side ZCAT3035 1330 a Within 360 40 Within 360 14 17 1 57 1 57 14 17 Ground wire 450mm Ground wire 280mm Connect to FG of the Connect to FG of the GOT main unit PLC power supply module power terminal block
2. Grounding wire gt Grounding 1 Use the thickest possible max 2 mm 14 AWG wires for the 100 200 VAC and 24 VDC power cables Be sure to twist these wires starting at the connection terminals To prevent a short circuit should any screws loosen use solderless terminals with insulation sleeves 2 When the LG terminals and FG terminals are connected be sure to ground the wires Do not connect the LG terminals and FG terminals to anything other than ground If LG terminals and FG terminals are connected without grounding the wires the PLC may be susceptible to noise In addition since the LG terminals have potential the operator may receive an electric shock when touching metal parts 5 6 Connection Cable Wiring e Do not bind connection cables with the main circuit high voltage heavy current or I O signal cables or lay them close to each other e When using A8GT CLIEXSS 1 or A8GT CL_IBS ground wires as below i When using A8GT CLIEXSS 1 cable Disconnected Plc GOT 3 A8GT CLIBS _ a 2 i D P l osn e ene J Q A a ie 2SQ wire FG terminal i cm or less X sS 1 Connect the LG and FG terminals of GOT unit power to the ground through the terminal block with one wire 2 Use FG wires of 28 cm or less for the A8GT CLIBS cab
3. 1M byte Built in memory Possible to expand to A956W GOT A956WGOT TBD a maximum of 9M bytes by using a memory board 24VDC Debug stand A9GT 50WSTAND Debug stand for A956W GOT Protective sheet A9GT 50WPSC Transparent protective sheet for A956WGOT A9GT 50WQBUSS For A956WGOT bus connection small connector type Bus connection For QCPU Q mode board For A956WGOT bus connection small connector type RST ONES For A QnA Motion controller CPU For Multi drop bus connection small connector type MO TFOBUSZSU For QCPU Q mode Bus connection For bus connection small connector type For Multi drop bus connection small connector type For AY56WGOT Direct connection to CPU Computer link AYGT 50WRS2 connection Microcomputer connection and RS 232C connection For A956WGOT Direct connection to CPU Computer A9YGT 50WRS4 link connection Microcomputer connection and RS 422 connection Serial communication board A7GT J71AP23 For MELSECNET II optical link connection Data link module A7GT J71AR23 For MELSECNET II coaxial link connection A 7GT J71AT23B For MELSECNET B connection A7GT J71LP23 For MELSECNET 10 optical loop network connection A 7GT J71BR13 For MELSECNET 10 coaxial bus network connection Control PN A8GT J61BT13 For CC Link connection for use as inteligent device Communication station w Link A8GT J61BT15 For CC Link connection for use as remort device station Ethernet Communication A9GT J71E71 T For Etherne
4. Analog I O signal lines gt 250V DC power type Immunity test in which Power line between line lightening surge is applied and ground 0 5kV to the product Data communication port 0 5kV Power line 3V Data communication port 3V Immunity test in which burst noise is applied to the power line and signal lines EN61000 4 4 Fast transient burst noise EN61000 4 5 Surge immunity EN61131 2 22 993 Immunity test in which a noise inducted on the power and signal lines is applied Instantaneous Test for checking normal power failure operations at DC power type and voltage dips instantaneous power 10ms interval 1s or more immunity failure Test for checking normal Radiated RF operations when the DC power type immunity power supply unit input 20 4V 28 8V voltage is fluctuated Test for checking if the External power unit becomes faulty with a supply transient voltage of the DC power type fluctuation internal and external input 20 4V 26 4V immunity sides of the power supply unit or unit power supply EN61000 4 6 Conducted RF immunity 19 1 The GOT is an open type device device installed to another device and must be installed in a conductive control panel The above test items are conducted in the condition where the GOT is installed on the conductive control panel and combined with the Mitsubishi PLC 2 QP Quasi peak value Mean Average value 3 The above test items are conducted in
5. Common grounding e For grounding a cable use the cable of 2 mm or more Position the ground contact point as closely to the sequencer as possible and reduce the length of the grounding cable as much as possible a An example of independent grounding Power equipment Servo etc Connection cable E Grounding terminal block Panel Grounding terminal roundin g g block Grounding for control system Grounding for power system For control system grounding apply single point grounding for one system Especially for the devices communicating each other be sure to earth the grounding wire at one point 15 b An example of common grounding Power equipment Servo etc Grounding terminal block Panel grounding Use a grounding wire as thick and short as possible Apply single point grounding for one system 5 5 Connecting to the GOT Power Section The following diagram shows the wiring example of power lines grounding lines etc to the GOT power section os 100 110VAC When using 100VAC a 0 INPUT h D 100 240VAC Fuse Da a Le FG Z a KAKA IK RIRIRICY LDC 9 i 24VDC 9 When using 24VDC A956GOT 9 INPUT FG OV 24V RIRES Booo aoaaa naana ao
6. Unit mm inch 29 d For other Bus Connection cables e Wrap the cable shield material around the cable so that the back aluminum foil side shield side of the cable shield material is exposed at both ends of the cable Ferrite core GOT side 7 RCAT3035 1330 PEG SIUR 130 6127 Cable shield material 1 5 12 Within 250 Within 250 Unit mm inch 1 The back aluminum foil side of the cable shield material shield side should be exposed The aluminum foil side is exposed z Aluminum foil side Cable Shield material 30 2 CPU Direct Connection a For RS 232C cable QC30R2 e Peel the sheath with the length shown below at both ends of the cable and expose the shield braided wire for grounding Ferrite core GOT side _ _ ZCAT3035 1330 _ PLC CPU side 5 12 Within 300 1 57 11 81 Unit mm inch b For RS 422 cable AC30 100 300R4 25P e Peel the sheath with the length shown below at both ends of the cable and expose the shield braided wire for grounding Ferrite core GOT side Fe ed eee PLC CPU side Yj i 5 12 Within 250 Unit mm inch 1 The back aluminum foil side of the cable shield material shield side should be exposed Refer to section 6 3 2 1 b 31 3 Computer Link Connection a For
7. chances of this phenomenon occurring With the LCD panel situations with luminous points points that stay lit up and dark points points that do not light up may occur This is a feature of the LCD panel and is not a malfunction The built in FLASH ROM memory allows old data be overwritten by new data Data backup power supply is not needed Note that either of the communication board slot and communication module interface may only be used The A956WGOT backlight cannot be replaced by the user The screen saving back light OFF function of GOT is extended thus reducing burn in of the display panel and extending longevity of the back light 3 3 Power Supply Specifications Item Input power supply voltage 24VDC 10 15 Input max power W 22 Inrush current Ap 61 max 30VDC max load Permissible instantaneous 1 19 2VDC or more power failure time ms er By noise simulator of 500Vp p noise voltage 1s noise width and 25 to 60Hz noise frequency TR 500VAC for 1 minute across DC external terminals and Dielectric withstand voltage sarih Insulation resistance 10M2 or larger by insulation resistance tester Applicable wire size mm 0 75 to 2 Applicable solderless terminal RAV1 25 3 V2 S3 3 V2 N3A FV2 N3A Applicable tightening torque Necm 59 to 88 Terminal block terminal screw When an instantaneous power failure occurs for the time exceeding the permissible instantaneous power failure time in the
8. 24VDC power supply the GOT may be reset In such a case the GOT will automatically return and start communicating As the communication between the GOT and PLC is stopped when an instantaneous power failure occurs some object functions may not be performed normally 4 Names of the Parts 1 00000000000000000 M 8 Description Shows the screen 2 Used to reset the hardware of the GOT invalid for bus Reset button connection Used to set the condition of access to the compact flash card when it is loaded during power on Factory set to OFF Compact flash card OFF Access from GOT to compact flash card inhibited access switch ON Access from GOT to compact flash card enabled When a memory card interface unit is used a compact flash card cannot be used Therefore turn this switch OFF Indicates whether the compact flash card may be loaded unloaded or not Off Compact flash card may be loaded unloaded When switch 3 is OFF On Compact flash card must not be loaded unloaded When switch 3 is ON RS 232C interface ron connection of personal computer For connecting the bar code
9. is installed on the GOT their mounting positions should be as shown in the figures below Z Communication module 80mm 3 15inch le C x or more ld gt B i 100mm 3 94inch 7 4 gt or more 50mm omore y5 Other yy 1 97inch i or more h device Vj 80mm 3 15inc or more te fA Vb Communication module Mounting Communication module Connection cable Dimension mm ee meee cable 114 Connect to option module E meee A9GT BUSSU A9GT BUS2SU MAX 185 ATGT J71AP23 ATGT J71LP23 J71AP23 A7GT J71LP23 ATGT J71AP23 ATGT J71LP23 MIN MN A7GT J71AR23 A7GT J71BR13 A9GT 50WRS2 A9GT 50WRS4 B A9GT 50WQBUSS A9GT 50WBUSS 74 RS 232C cable for connecting the personal computer and the bar code reader Connect to interface RS 232C 1 At least 80 mm is necessary for the A section measurement Varies depending on the connection cable s curve radius 2 At least 50 mm is necessary for the A section measurement 11 3 Mounting method a Put the GOT main unit into the panel opening with its front facing outward b Mount the GOT in the following four locations on its top and bottom Top Bottom ol MN AN omar a o 00000000000000000 n yg a o 00000000000000000 p o oer Mounting Position Mounting Position c How to mount and fix the mounting fixture is given below 1 In
10. substances such as sawdust or wiring debris inside the modle GOT main unit e General view of noise countermeasures There are two types of noise radiated noise which is transmitted through the air and conducted noise which is transmitted through a connection wire In noise countermeasures the both two types of noise should be taken into account As the noise countermeasures there are the following three methods 1 Block noise a Keep signal wires away from a possible noise source as power wires or high power driving circuits b Shield signal wires 2 Reduce generated noise a Reduce the noise generated from high power motor drive circuits 3 Ground noise without fail a Earth the grounding wire to the ground without fail b Use a grounding wire as thick and short as possible to ensure low grounding impedance c Separate the grounding between power and control systems 13 1 Power supply wiring e Separate the GOT s power supply line from the lines for I O devices and power devices as shown below When there is much noise connect an insulation transformer Power supply wiring diagram Main power GOT power Insulation supply supply Transformer FN Fuse 200VAC O Oo O Oo 3 3 L AC DC GOT LT I O power supply LoS o O gt O equipment Main circuit equipment AN Lo o Main circuit equipment e 24VDC wires should be
11. twisted as dense as possible Connect the modules with the shortest distance Also to reduce the voltage drop to the minimum use the thickest wires possible 0 75 to 2mm Use a solderless terminal for M3 screw Also be sure to tighten the M3 screw within tightening torque 0 55 to 0 88 Nem in order not to cause trouble e Do not bundle the 24VDC wires with or run them close to the main circuit high voltage large current and I O signal lines Reserve a distance of at least 100 mm from adjacent wires e As a countermeasure to power surge due to lightening connect a surge absorber for lightening as shown below Lightening surge absorber connection diagram anz Surge absorber for lightening POINT 1 Separate the ground of the surge absorber for lightening E1 from that of the GOT E2 2 Select a surge absorber for lightening whose power supply voltage does no exceed the maximum allowable circuit voltage even at the time of maximum power supply voltage elevation 2 Grounding e For grounding perform the following Use a dedicated grounding wire as far as possible Grounding resistance of 100 or less e When a dedicated grounding cannot be performed use 2 Common Grounding shown below Also be sure to take noise countermeasures other than grounding Power equipment Q Grounding Class 3 grounding ingee Good 3 Joint grounding Not allowed 1 Independent grounding Best 2
12. 0EXSS 1 a QCPU QC06 12 30 50 100B a Q mode A9GT QC150 200 250 300 350BS x RS 232C i aa A peed connection RS 422 AC30 100 300R4 25P Ep communication Co RS 232C oo User created cable f RS 422 AC30 100 300R4 25P connection OR communication User created cable CC Link connection CC Link dedicated cable Ethernet connection Category 5 twisted pair shield cable 10BASE T O To make applicable to the EMC directive each cable including user created cables must be manufactured Refer to section 6 3 2 for the cable manufacturing method 26 6 3 Wiring precautions the part which matches the EMC Directives Connect and wire GOT equipment as instructed below If the GOT equipment is configured in a way that differs from the following instructions then the system will not comply with EMC directives 6 3 1 Method to connect the power wire and ground wire 1 With the power wire be sure to attach the ferrite core TDK type ZCAT3035 1330 within 90 mm of the GOT terminal module Lead the power wire and ground wire as shown in Section 6 1 2 2 Always ground the FG wires GOT terminal block Within 90mm 3 54 inch Ferrite core 4 Wrap the power wire around the ferrite core a When connecting CC Link use the grounding wire of the FG1 terminal on the CC Link communication module to connect to the FG terminal of the GOT power section Use a grounding wi
13. False output or malfunction can cause an accident A 4 STARTUP MAINTENANCE PRECAUTIONS When opening the panel on which the GOT is installed always power off the GOT Not doing so can cause the GOT to fail or malfunction When power is on do not touch the terminals Doing so can cause an electric shock or malfunction Do not change the extension number setting switch and I O slot setting switch setting during power on Doing so can cause a malfunction Before starting cleaning or terminal screw retightening always turn the power OFF before starting cleaning or terminal screw retightening Not switching the power off in all phases can cause a module failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or module When touching the GOT communication unit and or option unit or before touching the panel with the GOT installed touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause the unit to fail or malfunction CAUTION Do not disassemble or modify the module Doing so can cause a failure malfunction injury or fire Do not touch the conductive and electronic parts of the module directly Doing so can cause a module malfunction or failure The cables connected to the module must be run in ducts or clamped Not doing so can cause th
14. Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
15. MITSUBISHI AIYS6WGOT TBD User s Manual Hardware Thank you for choosing the MELSEC GOT Series To ensure correct use of this equipment please read this manual carefully before operating it MODEL AQS56WGOT U HW pads 1DM104 IB NA 0800184 G 0608 MEE MITSUBISHI Graphics Operation Terminal SAFETY PRECAUTIONS Always read before starting use When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in the manual Also pay careful attention to safety and handle the module properly These precautions apply only to the installation of Mitsubishi equipment and the wiring with the external device Refer to the user s manual of the CPU module to be used for a description of the PLC system safety precautions These e SAFETY PRECAUTIONS e classify the safety precautions into two categories DANGER and CAUTION a Procedures which may lead to a dangerous condition and DANGER cause death or serious injury if not carried out properly Procedures which may lead to a dangerous condition and Z CAUTION cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by Z CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it t
16. OT backlight goes out the display section turns black and causes the monitor screen to appear blank while the input of the touch switch s still remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate Note that the following occurs on the GOT when the backlight goes out e The monitor screen disappears even when the screensaver is not set e The monitor screen will not come back on by touching the display section even if the screensaver is set CAUTION Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm apart Not doing so noise can cause a malfunction A 2 MOUNTING PRECAUTIONS Before installing or removing the GOT main unit to or from an enclosure always turn the GOT power OFF before installing or removing the GOT main unit to or from an enclosure Not doing so can cause a module failure or malfunction Before loading or unloading the communication board communication module external I O interface module or memory card interface module to or from the GOT always turn the GOT power OFF before loading or unloading the communication board communication module external I O interface module or memory card interface module to or
17. Our tests have been carried out on a panel having the damping characteristics of 37 dB max and 30 dB mean measured by 3 m method with 30 to 300 MHz 2 Connection of power and ground wires Ground and power supply wires for the GOT must be connected as described below a Provide an earthing point near the GOT Earth the power supply s FG terminal FG Frame Ground with the thickest and shortest wire possible The wire length must be 30cm 11 18in or shorter The FG terminal function is to pass the noise generated in the GOT to the ground so an impedance that is as low as possible must be ensured As the wires are used to relieve the noise the wire itself carries a large noise content and thus short wiring means that the wire is prevented from acting as an antenna Note A long conductor will become a more efficient antenna at high frequency 21 3 Electrical shock prevention In order to such as the operators from electric shocks the control box must have the following functions a The control cabinet must be equipped with a lock so that only skilled or qualified personnel b The control cabinet must be fitted with advice which automatically stops the power supply when the cabinet is opened 4 Dustproof and waterproof features The control box also has the dustproof and waterproof functions Insufficient dustproof and waterproof features lower the insulation withstand voltage resulting in insulation destructi
18. RS 232C cable The user needs to fabricate the RS 232C cable which is used to connect the GOT and Computer link unit side serial communication computer link module or PLC CPU with computer link function The RS 232C cable connection diagram and the connector are as follows 1 Connection diagram e If D sub 9 pin is used for the connector of the computer link unit A1SJ71QC24 R2 A1SJ71UC24 R2 A1SJ71C24 R2 A1SCPUC24 R2 A2CCPUC24 QJ71C24 R2 QJ71CMO GOT side Computer link module side e If D sub 25 pin is used for the connector of the computer link unit AJ71QC24 R2 AJ71UC24 GOT side eser e oroj ome a Braided shield 32 2 Precautions for manufacturing cable e Make a twisted pair for each signal and SG e Connect the braided shield to the connector shell both ends e The cable used for the Mitsubishi EMC Directive compatibility test had the following specifications Specification Cable type Twisted pair shield cable Conductor section area mm 0 2 3 Connector connector cover e GOT connector Use the connector matching the following model for the GOT 9 pin D sub male inch screw type manufactured by DDK 17JE 23090 27 D3CC e Connector of computer link unit Refer to the user s manual of the serial communication computer link module or PLC CPU with computer link function 4 Cable production method e Peel the sheath with the length shown below at both ends of the cab
19. T A956GOT User s Manual Sold separately 1DM103 Relevant Manuals For relevant manuals refer to the PDF manual stored within the drawing software A 8 1 Overview This user s manual describes the system configuration specifications part names handling and outline dimensions of the A956WGOT Graphic operation terminal Referred to as GOT hereafter 1 1 Packing List After unpacking confirm that you have received the following products Quantity a ear GOT main unit Mounting fixture ae Sa Communication module securing fixture Seal For use when closing the bus connection board setting 1 switch confirmation hole oO If the protective sheet needs to be replaced please obtain the one that is to be purchased separately 2 System Configuration If AIS6WGOT is applicable to the EMC directive note that there are restrictions for the connection conditions For details refer to Chapter 6 EMC Directive 2 1 Overall Configuration Drawing software Communication module Communication board 1 Option e Memory board Compact Flash card Commercially Memory card interface module 1 External I O interface module 1 e Printer interface module 1 e Backlight e Protective sheet Debug stand Others Bar code reader Commercially 1 1 For details of the system configuration refer to the GOT A900 Series User s Manual Connection System Manual 2 2 Component List 256color
20. ambient temperature 25 C 50 000 Time when display luminance reaches 50 at the operating ambient temperature of 25 C Touch key 1 million times or more operating force 0 98N max Built in memo Number of write times 100 000 times Environmental protective Front section Equivalent to IP67 NEMA4 structure Panel inside IP2X tea ar ghd 215 8 46 W x 133 5 24 H x 70 8 2 79 D Panel cutting dimensions mm inch 205 5 8 09 W x 123 5 4 86 H Weight kg Ib c tibl ft k SW5D5C GTWORKS E Version K or later ompatible sottware package sw5D5C GOTR PACKE Version K or later Life 7 Backlight Hr 8 ia Wes 2 23 4 5 6 When parts must be changed consult your sales representative 8 If you run the monitor with A9S56WGOT the screen may flicker depending on the type of object shape fill pattern used when creating images This is due to the specifications of the LCD panel and is not a malfunction Be sure to check the combination of the type of pattern and color on the machine before using For patterns likely to flicker and countermeasures against flickers refer to the reference manual of GT Designer or GT Designer 2 Depending on the display color combination the visibility of the screen may be lower from certain viewpoints Before using check the color combination with the machine installed in the usage environment By designating bright colors for the basic color types you can decrease the
21. connector conversion box 3 Specifications 3 1 General Specifications litem O Specifications ambient 0 to 55 C temperature Storage ambient tutors Ol Ptr to 60 C temperature Operating ambient 10 to 90 RH non condensing humidity Storage ambient 10 to 90 RH eee humidit Vibration __ Frequency Acceleration Amplitude Sweep Count Conforms In case of 10 to 57Hz 10 to 57Hz 57Hz 0 075mm 10 times in to JIS intermittent 57 to 9 emis each of X Y B3502 and vibration 150Hz and Z Resistance IEC Incase of 10 to 57Hz Eas 0 035mm directions 61131 2 continuous 57 to Tone for 80 vibration 150Hz SS minutes Shock Conforms to JIS B3502 and IEC 61131 2 resistance 147m s 3 times in each of X Y and Z directions Operating No corrosive gas atmosphere Operating 2000m max altitude Installation site Inside control box Overvoltage ll or less category 1 Contamination 2 or less level 2 rile 2 3 Indicates the element in the distribution system between the public electricity grid and the mechanical equipment inside the premises that the relevant device is assumed to be connected to Category II applies to devices such as those that draw their power supply from fixed installations The surge voltage withstand capability of devices with ratings up to 300V is 2 500V This index gives a measure of the incidence of conductive materials in the environme
22. d 1 Bus connection board Serial communication board face module t Communication cable 1 Bus connection cable CC Link dedicated cable Twisted pair shield cable RS 232C cable RS 422 cable 1 See section 6 2 2 or section 6 2 3 for information about models and hardware versions that are applicable to the EMC directive 2 EMC directive is not applicable when using an option module 23 6 2 2 Connection Format Connection conditions where the A956WGOT is applicable to the EMC directive are shown below CPU Direct connection Computer link connection RS 422 E 0203 MELSECNET connection x CC link Intelligent device E 0203 connection x Ethernet connection E 0203 lt How to read the table gt The table indicates the GOT compatible hardware version for each connection pattern and the compatibility date Please use the GOT whose hardware version is later than that described E 0203 _ Compatibility 0203 3 date Month Hardware version Year Last 2 digits of A D year X indicates the product is not compliant with the EMC Directive If connecting to a PLC not from this company MELSEC Q series MELSEC QnA series MELSEC A series refer to the manual of the connected device PLC microcomputer for information about the applicability of the EMC directive 24 6 2 3 When the communication board module is used Be sure to use the communication boards communica
23. dseteQerecaatinteess soavemsdieesderteanpecsaitaiwdabsnapeundncasdentenacesee 18 6 1 Requirements for conformance to EMC Directive cccceecceeeeeeeees 18 6 1 1 Standards applicable to the EMC Directive ccccceeessseeeeeeeees 19 671 2 Controleabin Gt nre ira a E serene 21 6 1 3 Grounding esea eras Bases atten ech ene eet a leat E heres 22 6 2 System Configuration when EMC Directive is Applicable 0 23 6 2 1 Overall COMMGUPALON ssri yee res lewadis ste aana ENESE Nae nee 23 6 2 2 CONMNGCHON FORMAL cc ccaetecstesccessawacdoiules Neceas seaedcea AOA AAEE 24 6 2 3 When the communication board module is used 000eeeeeee ees 25 6 2 4 About the Cable Used mined ei e E E eiti 26 6 3 Wiring precautions the part which matches the EMC Directives 27 6 3 1 Method to connect the power wire and ground Wire e c0eee 27 6 3 2 Grounding the ground Cable cccceecccceceseeeeeeeeseeeeeeeeeeeaaeeeeeeees 28 6 3 3 Grounding NG CaDl eG riea ade ln Aare Alt 37 PROD CNC OS enpa E EA EA A E ue ne une elie es 38 Appendix1 External DIMENSIONS cccccseecesseseeeeeeeeeessaseeeeseeseensaseeeenees 38 Appendix2 Depth Dimensions when Mounting Various Modules 39 A 7 Manuals The following manuals are related to this product Refer to the following list and request the required manuals Detailed Manual Type Core A950GOT A951GOT A953GO
24. e module or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault When unplugging the cable connected to the module do not hold and pull the cable portion Doing so can cause the module or cable to be damaged or can cause a malfunction due to a cable connection fault DISPOSAL PRECAUTIONS Z CAUTION When disposing of the product handle it as industrial waste A 5 Revisions The manual number is noted at the lower right of the top cover Feb 2001_ IB NA 0800184 A First edition May 2001 IB NA 0800184 B Section 2 1 Partial addition Section 3 2 Feb 2002 IB NA 0800184 C Partial correction correction Faria corector PRECAUTIONS Mar 2002 B NA 0800184 D Partial correction correction Taniel correction 2 1 Chapter 6 EMC Directive Aug 2004 IB NA 0800184 E Manuals Section 3 1 3 2 6 2 3 Appendix1 Section 5 4 5 5 5 6 MODEL CODE change Changed from 13JT56 to 1DM104 Dec 2005 IB NA 0800184 F Partial corrections Section 3 2 Aug 2006 IB NA 0800184 G Partial corrections Section 2 1 3 2 3 3 6 1 1 6 3 2 Partial additions SAFETY PRECAUTIONS Manuals Section 6 2 4 6 3 1 6 3 2 6 3 3 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi electric Corporation cannot be held responsible for any problems
25. e mounting angle other than the above Therefore the temperature inside the enclosure should be within 40 C Tighten the screws in the following specified range Tightening Torque Range Ground terminal screw M3 screw i Terminal block terminal screw M3 screw PHO OON EM Mounting fixture screw M4 screw Communication board mounting screw M3 screw Communication module mounting screw M3 screw 36 to 48Necm Option module mounting screw M3 screw Case fixing screw M3 screw RS 232C connector mounting screw 4 40 UNG inch screw PAGANE Memory board mounting screw M2 6 screw 25 to 35Necm 5 2 Installation Method 1 Mounting panel cutting dimensions When mounting the GOT on a control box door user made mounting base or the like the door or mounting base must be cut as indicated below L A j A mm inch B mm inch 205 5 8 09 123 5 4 86 Panel opening m A956WGOT 14 0 0 04 0 0 1 0 0 04 0 0 2 Mounting position When mounting the GOT the following clearances must be left from the other devices 4 YY Vt 80mm 3 15inch 100mm 3 94inch or more or more a gt 7 lt gt Y Other 50mm 50mm 1 97inch 1 97inch device or more or more 80mm 3 15inch Plate a or more pe within 2 to 4mm 0 08 to 0 16inch a When a communication module or a connection cable is installed When a communication module or a connection cable
26. e to the panel with a cable clamp AD75Ck e For another bus cable or RS 422 cable ground the shield side of the cable shield material to the panel with a cable clamp AD75CK Cable clamps 37 Appendices Appendix1 External Dimensions 23 5 168 6 61 j e T 0 61 T ee Tr om ise LU amp J tt i 168 6 61 OQ gt ej 215 8 46 i 205 8 07 l Unit mm inch 38 Appendix2 Depth Dimensions when Mounting Various Modules Communication Communication board loading module loading Alm Goh Bimm inch Communication _AOGT 50WQBUSS 55 2 17 z aem A9GT 50WRS2 A9GT 50WRS4 103 4 06 A9GT QBUS2SU A9GT BUSSU CT PO 105 4 13 99 8 3 93 c a A7GT J71AP23 A7GT J71LP23 99 8 3 93 ommunication A7GT J71AR23 A7GT J71BR13 99 8 3 93 mene A7GT J71AT23B 121 8 4 80 A8GT J61B113 A8GT J61BT15 104 8 4 13 A9GT J71E71T 96 0 3 78 1 This dimension is between 185mm 7 28 maximum and 80mm 3 15 minimum depending on the optional fiber cable and connector connected 2 This dimension is between 80mm 3 15 maximum and 53mm 2 09 minimum depend
27. from the GOT Not doing so can cause a module failure or malfunction CAUTION Use the GOT within the general specifications environment given in this User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When mounting the GOT main unit to an enclosure tighten the mounting screws in the specified torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or module When loading the communication module to the GOT main unit fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to the damage of the screws or module WIRING PRECAUTIONS Before starting wiring always turn the GOT power OFF before starting wiring Not doing so may cause an electric shock product damage or malfunction A 3 WIRING PRECAUTIONS CAUTION Please make sure to ground FG terminal of the GOT power supply unit by applying Class D Grounding Class 3 Grounding Method or higher which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the power supply module on the GOT after confirming the rated voltage and terminal arrangement of the prod
28. he sections 6 1 1 through 6 3 3 summarize the precautions on conformance to the EMC Directive of the machinery constructed using the GOT The details of these precautions has been prepared based on the requirements and the applicable standards control However we will not assure that the overall machinery manufactured according to these details conforms to the above mentioned directives The method of conformance to the EMC directive and the judgment on whether or not the machinery conforms to the EMC Directive must be determined finally by the manufacturer of the machinery 6 1 1 Standards applicable to the EMC Directive Standard value 30M 230MHz QP Electromagnetic I0ABHV MOM apie Ses emesos ron he measurement range adiated noise product are measured 230M 1000MHz QP EN61000 6 4 f 37dBuV m 30m 2001 measurement range Electromagnetic 150k 500kHz QP 79db EANN emissions from the l Mean 66dB noe product to the power line 500k 30MHz QP 73qB are measured Mean 60dB Immunity test in which 2 3 2 3 EN61000 4 2 static electricity is applied 4kV Contact discharge Electrostatic ee rae to the cabinet of the 8kV Aerial discharge immunity equipment EN61000 4 3 Immunity test in which 80 1000MHz 10V m Radiated field _ field is irradiated to the 1 4 2GHz 10V m AM modulation product 80 AM modulation 1kHz Power line 2kV Digital I O 24V or more 1kV Digital I O 24V or less gt 250V
29. hen using a CC Link dedicated cable between GOT and GOT Ferrite core GOT side _ _ ZCAT3035 1330 _ GOT side 130 6 12 5 12 Within 230 40 49 Within 230 Unit mm inch 9 06 1 57 1 57 9 06 34 5 Ethernet Connection Twisted pair shield cable e Peel the sheath with the length shown below at both ends of the cable and expose the shield wire for grounding Ferrite core GOT side ZCAT3035 1330 Ethernet module side 5 12 Within 230 40 40 Within 400 Unit mm inch gt 9 06 1 57 1 57 15 75 6 Other PLC and Microcomputer connection It is necessary for the user to create the cable used to connect GOT with a PLC or a microcomputer from another company RS 422 cable or RS 232C cable Refer to the GOT A900 series User s Manual Connection System Manual for information about the cable creation method POINT When connecting GOT to a PLC or microcomputer from another company configure the system so that the EMC directive specifications from the connection destination are applicable The contents shown below are a collection of the contants that should be enforced when made applicable to the EMC directive however the final decision to make the device applicable to the EMC directive and how to make it applicable must be made by the manufacturer of the machine device a For RS 422 cable e Each signal wire excluding SG and FG shou
30. ing on the coaxial cable connected 39 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties N For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a Country Region Sales office Tel U S A Brazil Germany U K Italy Spain France South Africa Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Mitsubishi Electric Euro
31. involving industrial property rights which may occur as a result of using the contents noted in this manual 2001 MITSUBISHI ELECTRIC CORPORATION A 6 Contents TOVGTVIGW meara teanen ua aa a ea Pau S se E atasue a seen d se E T 1 Lil PACKING LIS cinisdocsvsscecetnnandoveudecaratanntidsldedcdaasnasedsusdlesertdsaeddenes EREEREER 1 2 System Configuration a esre d eter cies Gc odusk des pest iaaa E EER E inata Ean eae 2 2 1 Ov rallGonfig ration renn E E E E ER 2 2 2 Component Listrier a e a a ae Se 2 SS POCINC ALOIS ara a Sr E NEA E N AN Y 4 31 General Specifications sisa rss e E E EA ES 4 3 2 Performance SPecificauions wives eile ee etait ees 5 3 3 Power Supply Specifications ccccccsseecececeesseeeeeeeeesseeeeeeeeesseeesesanaaees 7 4 Names ofthe Pans iseto ienai erii a A ei i EEE E E aE 8 Haee ae MEE E teat aude sv E N A E E A SaaC es 10 5 1 Handling INSUUCTIONS susie Sevsetce rel ets te ed Cocaine et ae whe 10 5 2 Installation Method i 1 p sai tadessccmane vnisnsen dxncnunnrs varius auseuaah Wa anevcacucuiuh denetweawete 10 Bid WINING Cia Pa M creases siete cine resr taut bee a E a S S 12 5 4 The precautions on the wiring ccccssececssseeeceeeseenseseeeeeeeeeensaseeeneaeeeens 13 5 5 Connecting to the GOT Power Section c ecceeeeeeseeeeeeeeeeaeeeeeeeeens 16 5 6 Connection Cable WIninG iiio s2 1escees20 iV eeune arcade y sraasves tod eceumeetsacede padres 17 6 EMC Directive ccc sacccnceecc
32. ld be made into a two power wires and connected then twisted e Make the SG wire more than two wires and connect e Wrap the cable shield material around the cable so that the back aluminum foil side shield side of the cable shield material is exposed at both ends of the cable 35 Ferrite core Other PLC and GOT side 7 2CAT3035 1330 n Microcimputer side Near the connection destination Near the connection destination Unit mm inch 1 The back aluminum foil side of the cable shield material shield side should be exposed Refer to section 6 3 2 1 b b For RS 232C cable e Each signal wire excluding SG FG is twisted with SG RD E SD SG SG e Peel the sheath with the length shown below at both ends of the cable and expose the shield braided wire for grounding Ferrite core Other PLC and A a E AT3035 1 S60 ee side Near the connection destination 5 12 Within 230 Q 9 06 1 57 1 57 Near the connection destination Unit mm inch 36 6 3 3 Grounding the cable Ground the cable grounding sections and grounding wire to the control panel where the GOT and base unit are grounded A the panel with the e Bus connection cable For A8GT C100 C200 300EXSS A8GT C100 200 300EXSS 1 A8GT C100 200 300BS RS 232C cable CC Link dedicated cable and Twisted pair shield cable ground the shield braided wire and grounding wir
33. le 3 Do not connect the FG grounding wire of ABGT EXCNB cable 4 Connect the A8GT CLIBS cable s FG wire to FG of the GOT unit power terminal block 5 Connect the A8GT CLIBS cable s FG wire on the PLC side to FG of the PLC power supply module 6 Connect the LG and FG terminals of the terminal block on the PLC to ground with one wire 2 When using A8GT CL_IBS cable Connect the A8GT CLIBS cable s FG wires on the both sides to the FG terminals on the power terminal block of the both side GOTs 17 6 EMC Directive For the products sold in European countries the conformance to the EMC Directive which is one of the European Directives has been a legal obligation since 1996 Also conformance to the Low Voltage Directive another European Directives has been a legal obligation since 1997 Manufacturers who recognize their products must conform to the EMC and Low Voltage Directives required to declare that their products conform to these Directives and put a CE mark on their products POINT Products that the EMC directive applies to are marked with the CE mark logo 6 1 Requirements for conformance to EMC Directive The EMC Directive specifies that products placed on the market must be so constructed that they do not cause excessive electromagnetic interference emissions and are not unduly affected by electromagnetic interference immunity The applicable products are requested to meet these requirements T
34. le and expose the shield braided wire for grounding e The cable must be 15m or shorter Ferrite core GOT side p ZCAT3035 1330 Computer link module side 130 6 12 6 12 Within 230 40 40 Within 400 9 06 1 57 1 57 j 15 75 Unit mm inch 33 b For RS 422 cable AC30 100 300R4 25P User created cable Refer to the GOT A900 series User s Manual Connection System Manual for information about the cable creation method e Wrap the cable shield material around the cable so that the back aluminum foil side shield side of the cable shield material is exposed at both ends of the cable Ferrite core GOT side 7 ZCAT3035 ae PLC Ore side at 5 12 a shield material 1 Within 250 Within 400 Unit mm inch 9 84 15 75 PLC CPU side connector varies depending on the cable used 1 The back aluminum foil side of the cable shield material shield side should be exposed Refer to section 6 3 2 1 b 4 CC Link Connection CC Link dedicated cable e Peel the sheath with the length shown below at both ends of the cable and expose the shield braided wire for grounding e When using a CC Link dedicated cable between GOT and PLC Ferrite core GOT side _ _CAT3035 1 330 _ PLC sige 130 130 5 12 5 12 Within 230 _ 40 49 Within 400 Unit mm inch 9 06 4 57 1 57 15 75 e W
35. nt in which the device is used A contamination level of 2 indicates an environment in which there is only contamination by non conducting materials but due to occasional condensation conductivity may occur Please do not use or store GOT in an environment with atmospheric pressure greater than the atmospheric pressure at sea level Om There is a possibility errors may occur if this point is not observed 3 2 Performance Specifications Specifications TFT color liquid crystal f display size Display Type 7 18 section 7 Resolution pixels 480 x 234 Disneys 155 52 6 12 W x 87 75 3 45 H color Flash ROM Memory 4 Capacity 1M byte built in user area A maximum of 8Mbytes can be extended Reference value for data transmission time When installing OS 640 to 760 seconds For basic functions BUS driver and system monitor approx 1 3Mbytes When downloading screen data 330 to 570 seconds For approx For RSAC 30 screens approx 600kbytes communication For connection of personal computer for bar code reader Roae uments connection 1 channel Option module For option module loading 1 channel interface Communication module vo H For communication module loading 1 channel interface 5 Communication board slot 5 Memory board slot Compact flash card slot Buzzer output Backlight 6 Cold cathode fluorescent tube backlight Backlight OFF screen saving time setting allowed ae Section 50 000 Operating
36. o the end user DESIGN PRECAUTIONS Depending on the GOT main unit communication board communication module or cable fault the output from the GOT interface module may remain ON or may remain OFF An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative For bus connection The CPU becomes faulty and the GOT inoperative For other than bus connection The GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction A 1 DESIGN PRECAUTIONS Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the G
37. on The insulation in our GOT is designed to cope with the pollution level 2 so use in an environment with pollution level 2 or better Pollution level 1 An environment where the air is dry and conductive dust does not exist Pollution level 2 An environment where conductive dust does not usually exist but occasional temporary conductivity occurs due to the accumulated dust Generally this is the level for inside the control box equivalent a control room or on the floor of a typical factory Pollution level 3 An environment where conductive dust exits and conductivity may be generated due to the accumulated dust An environment for a typical factory floor Pollution level 4 Continuous conductivity may occur due to rain snow etc An outdoor environment 6 1 3 Grounding It is necessary to use the GOT grounding terminal only when it is in the grounded condition Be sure to ground the grounding for the safety reasons and EMC Directives Functional grounding Improves the noise resistance 22 6 2 System Configuration when EMC Directive is Applicable Connection conditions and models where the EMC directive is applicable are shown below Available August 2006 6 2 1 Overall Configuration Soll Qmm Option m g A956WGOT External Memory 4 Option ee x Memory board Communication module 1 Compact Par eats Bus connection module CC Link communication module Ethernet communication module Communidation boar
38. pe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 l 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 China Taiwan Korea Singapore Thailand Indonesia India Australia Country Region Sales office Tel Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Mitsubishi Electric Asia Pte
39. re of 300 mm or less CC Link communication module terminal block iel eleli GOT FG AOINE terminal OO wmo E POINT Use a CE compatible product for 24 V DC external common power source for GOT Ground wire The EMC test run by our company was confirmed with the same panel components as the DENSEI LAMBDA type JWS 50 24 or DLP120 24 1 installed 27 6 3 2 Grounding the ground cable Manufacture the cable used with the GOT with the following method When manufacturing the cable a ferrite core cable clamp and cable shielding material are required The cable clamp used by Mitsubishi Electric for the EMC specification compatibility test is shown below e TDK brand ZCAT3035 1330 Ferrite Core e Mitsubishi Electric Model AD75CK cable clamp e Japan Zipper Tubing Co Ltd Zipper tube SHNJ type 1 Bus Connection a For A8GT C100 200 300EXSS e Cut the ground wire from the core where it protrudes from both ends of m Se wire Cut the cable e Peel the sheath with the length shown below at both ends of the cable and expose the shield braided wire for grounding Ferrite core PLC side lt 2CAT3035 1330 130 iin 360 40 40 Withi a5 ithin ithin Pi 14 17 Unit mm inch 14 17 1 57 1 57
40. reader Communication module Interface for communication module loading interface Compact flash card LED Compact flash card slot Slot for Compact flash card loading For connection Printer I F module Memory card I F module 8 Option module interface External I O module Cover of the memory board slot and the communication 9 Slot cover board slot Memory board slot Slot for memory board loading Communication board slot Slot for communication board loading Terminal block For power input Mounting fixture fitting portion For mounting fixture fitting 14 Ground terminal For earthing For safety please make sure to ground this terminal For confirming the extension number of the I O slot number B set with the bus connection board 15 us connection board setting If you are not using the A9GT 50WBUSS it is possible to switch confirmation hele attach the seal included with the GOT main unit to cover the Be careful not to touch the board inside the GOT main body by hand when mounting the memory board and the communication board 5 Handling 5 1 Handling Instructions When mounting the main unit to a control box or the like set the display section as shown below When the temperature inside the enclosure is 40 to 55 C or less the mounting angle should be in the range 60 to 105 degrees GOT Display section Enclostre etc The GOT will be deteriorated earlier if it is used at th
41. sert the mounting fixture into the fixture fitting portion of the GOT main unit 2 Tighten and fix the mounting screw within the specified torque range 5 3 Wiring diagram POINT Note that the terminals of the A956WGOT are arranged in the reverse order of the terminals of the A950GOT A951GOT A953GOT A956GOT 5 4 The Precautions on the Wiring Completely turn off the externally supplied power used in the system when installing or placing wiring Not completely turning off all power could result in electric shock damage to the product CAUTION Be sure to ground the FG terminal and LG terminal of the GOT power supply section to the protective ground conductor Not doing so could result in electric shock or erroneous operation When wiring in the GOT power section be sure that it is done correctly by checking the product s rated voltage and the terminal layout Connecting a power supply that is different from the rating or incorrectly wiring the product could result in fire or erroneous operation Tighten the terminal screws of the GOT power supply section within the specified torque range If the terminal screws are loose it could result in short circuits erroneous operation or erroneous operation Tightening the terminal screws too far may cause damages to the screws and or the module resulting in fallout short circuits or erroneous operation Be sure there are no foreign
42. t connection module A9GT FNB Exclusively used for optional function OS storage A9GT FNB1M Ay oe function OS storage expansion memory AQGT ENB2M For optional function OS storage expansion memory 2M byte AQGT ENB4M RA ee function OS storage expansion memory Memon poata For optional function OS storage expansion memory A9GT QFNB Exclusively used for optional function OS storage A9GT QFNB4M Fa oe function OS storage expansion memory A9GT QFNB8M a ie function OS storage expansion memory Compact flash Commercially available Compact Flash PC card card Compliant with FlashTM 1 Memory card ntetaco modile A1SD59J MIF For loading memory card PC card PC cards that can be used with memory card interface SRAM type module Compliant with PCMCIA Ver 2 1 or later Memory card A85GT C05H Cable length 2 0m For connection between GOT cable and memory card I F module External A8GT 50KBF For external I O connection module Primer interage A9GT 50PRF For Printer connection module Printer ESC P command compalibla rev Packard Printers reais nats ome Printer cable AC30PI0 20P Cable length 3 0m Bus extension AQGT A9GT QCNB Used for connection of the QCPU Q mode long connector box agcT acne ysgor bus For conversion from large type connector to small type A7GT CNB connector Used for connection of the A Q A Motion controller CPU long distance bus 1 Compact Flash TMisa trademark of Sun disk Network module Bus
43. the following conditions 30 230MHz QP 40dByuV m 10m in measurement range 230 1000MHz QP 47dBuV m 10m in measurement range 20 6 1 2 Control cabinet The GOT is an open type device device installed to another device and must be installed in a conductive control panel or cabinet It not only assure the safety but also has a large effect to shut down the noise generated from GOT on the control panel 1 Control cabinet a Use a conductive control cabinet b When attaching the control cabinet s top plate or base plate mask painting and weld so that good surface contact can be made between the cabinet and plate c To ensure good electrical contact with the control cabinet mask the paint on the installation bolts of the inner plate in the control cabinet so that contact between surfaces can be ensured over the widest possible area d Earth the control cabinet with a thick wire so that a low impedance connection to ground can be ensured even at high frequencies 22mmz2 wire or thicker is recommended e Holes made in the control cabinet must be 10 cm 3 94in diameter or less If the holes are 10cm 3 94in or larger radio frequency noise may be emitted In addition because radio waves leak through a clearance between the control panel door and the main unit reduce the clearance as much as practicable The leakage of radio waves can be suppressed by the direct application of an EMI gasket on the paint surface
44. tion modules shown below with A9S56WGOT If communication modules communication boards other than those shown below are used they are not applicable to the EMC directive A9GT 50WBUSS Hardware version B or later Bus connection A9GT BUSSU Hardware version B or later A9GT BUS2SU Hardware version B or later CPU Direct A9GT 50WRS2 Hardware version B or later connection RS 422 A9GT 50WRS4 Hardware version B or later Computer RS 232C A9GT 50WRS2 Hardware version B or later IAS aa RS 422 A9GT 50WRS4 Hardware version B or later connection CC Link connection A8GT J61BT13 Hardware version E or later Ethernet connection A9GT J71E71 T Hardware version C or later Confirm the hardware version with the products rating plate Products that the EMC directive applies to are marked with the CE mark logo a MITSUBISHI GRAPHIC OPERATION TERMINAL 0D E A970GOT TBA B B IN 100 240VAC 50 60Hz Zonas MAX 115VA N 0407 ER at Haerdware version L 4 Conformed standard MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN BD992C189H02 25 6 2 4 About the Cable Used If making the GOT applicable to the EMC directive be sure to use the cables shown below O EMC directive applicable x EMC directive not applicable EMC AC06 12 30 50B AC12 30 50B R A1SC07 12 30 50B A1SC05 07 30 50NB A QnACPU A8GT C12 30 50NB A370C12 25B Bus A9GT J2C10B A8GT C100 200 300EXSS connection A8GT C100 200 300BS A8GT C100 200 30
45. uct Not doing so can cause a fire or failure Tighten the terminal screws of the GOT power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or module Exercise care to avoid foreign matter such as chips and wire offcuts entering the module Not doing so can cause a fire failure or malfunction Plug the bus connection cable by inserting it into the connector of the connected module until it clicks After plugging check that it has been inserted snugly Not doing so can cause a malfunction due to a contact fault Plug the communication cable into the connector of the connected module and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or module TEST OPERATION PRECAUTIONS Before performing test operation bit device on off word device s present value changing timer counter s set value and present value changing buffer memory s present value changing for a user created monitor screen or system monitoring read the manual carefully to fully understand how to operate the equipment During test operation never change the data of the devices which are used to perform significant operation for the system