Home
Walking Surface User Manual
Contents
1. Sales LiteGait com GaitKeeper Designed for Rehab All MOBILITY RESEARCH products are distributed by MOBILITY RESEARCH and are warranted to the original registered product purchaser and the parts of the TRUE product the Product listed below under normal use and service shall be free of manufacturing defects in workmanship and materials only for the period of time beginning from the original date of purchase set forth below Motor Drive Motor Motor Controller Parts Electrical Wear Items Cosmetics Losses due to work stoppage lost revenues damages due to neglect or abuse ARE NOT covered by this warranty Shipping and handling charges ARE NOT covered by this warranty Repairs may be conducted at factory at the discretion of Mobility Research If a problem caused by a manufacturing defect occurs that cannot be resolved by the replacement of parts the problem will be resolved by replacing the current device with a remanufactured replacement device either the same model or one of comparable quality THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED MOBILITY RESEARCH SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE IF MOBILITY RESEARCH CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER
2. since the last activation To increase the speed press the button The speed of the walking belt will increase by 0 1 mph per button press to a maximum of 3 0 mph To decrease the speed press the button The speed of the walking belt will decrease by 0 1 mph per button press To Stop the walking belt select the button NOTE The walking surface will always start at the speed it was running when the stop button was last pressed or at 0 1 mph if the walking surface has been powered down since the last activation Display Hand control display cycles between time of session distance travelled and speed of walking belt Time s Distance m Speed kph TE E 1 Pie 1 TIME DISTANCE SPEED TIME SPEED TIME SPEED Pressing speed buttons returns display to speed display litegait com 800 332 WALK 480 829 1727 10 Designed for Rehab 4 CARE amp MAINTENANCE CARE amp MAINTENANCE It is important to perform the minor maintenance tasks described in this section Failure to maintain the Walking Surface as described here could void the Warranty To reduce the risk of electrical shock always unplug the unit from its power source before cleaning or performing any maintenance tasks INSPECTION Inspect the walking surface daily Look and listen for loose fasteners unusual noises worn or frayed power cords and any ot
3. 15 1 Figure 1 Designed for Rehab 2 SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WARNING READ ALL INSTRUCTIONS BEFORE USING THE WALKING SURFACE CAUTION Health related injuries may result from incorrect or excessive use of exercise equipment The GKmini Walking Surfaces are intended for light commercial use WARNING GKmini Walking Surface REQUIRES use with the LiteGait or GKmini Walker Style handle bars Operation without LiteGait or GKmini handle bars may result in injury to user The walking surface is only safe when used properly with the appropriate LiteGait products GKmini includes a magnet that must be attached to your LiteGait following the provided instructions This safety feature may not be tampered with LiteGait GKmini Walker Style Handlebars Without LiteGait or GKmini handlebars WARNING Do not move the device by lifting the control DANGER To reduce the risk of electric shock always unplug the treadmill before cleaning WARNING To reduce the risk of burns fires and electric shock or injury to persons follow these instructions e Attach the safety magnet to LiteGait prior to use e Do not exceed maximum weight of 350165 e Avoid exiting treadmill while leaving the tread belt in motion e Donotallow power cable or hand held cables to contact walking surface belt during operation Cables must be routed away from the walking surface belt e Never w
4. 9 1727 11 Designed for Rehab 5 TROUBLESHOOTING TROUBLESHOOTING Problem Treadmill belt slips when walking on it Solution Tighten the belt using the instructions below Set the treadmill flat and tension and align the belt according to the following procedures 1 2 Connect power pendant controller to treadmill Then connect magnetic key Keeping the belt centered on both rollers use a Phillips screwdriver to tighten the tensioning screws evenly until you can no longer easily see the slots in the channels behind the ends of the rollers Turn on the treadmill starting at its slowest speed and make sure everything is running smoothly with no out of the ordinary noises If the belt quickly runs to one side tighten the tensioning screw on that side until the belt slowly centers Use one foot to apply all your weight to the belt If the belt sticks to the deck and stops moving tighten each tensioning screw in 1 2 turn increments the same amount Then retest When the belt stops sticking from one foot pressure speed the treadmill up to 1 mph 9 presses of the speed up command Walk heavily on the treadmill If the belt sticks tighten each tensioning screw 1 2 turn and repeat When properly tensioned look at how the edge of the belt is running relative to the trim ledge If it is angling toward the right at the front of the treadmill loosen the tensioning screw on the right 1 2 turn
5. GaitKeeper Designed for Rehab GKmini Motorized Walking Surface used to Stimulate Walking Pattern Brought to you by Mobility Research INC GaitKeeper ee Designed for Rehab TABLE OF CONTENTS 1 A 2 Safety INStrUCtI ONS 6 OMe VO UO 9 A amp 10 5 Troubleshooting 11 7 12 7 Resource Directory 13 litegait com 800 332 WALK 480 829 1727 Designed for Rehab 1 ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Basic Guidelines for Setting Up Your Treadmill After removing the treadmill from the packaging place your treadmill on a clean level surface Make sure the electrical cord easily reaches a grounded three pronged outlet Do not allow the treadmill assembly to rest on the cord Important Electrical Requirements 110V 240V Your GaitKeeper treadmill requires a110 volt 240V Alternating current AC 15 amp 110V 8 Amp 240V grounded outlet circuit This means nothing else can be plugged into the same circuit Danger Do not use an extension cord or ungrounde
6. THIS LIMITED WARRANTY ALL SUCH WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY NO MOBILITY RESEARCH RESELLER AGENT OR EMPLOYEE 15 AUTHORIZED TO MAKE ANY MODIFICATION EXTENSION OR ADDITION TO THIS WARRANTY MOBILITY RESEARCH 15 NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY INCLUDING BUT NOT LIMITED TO LOST PROFITS DOWNTIME GOODWILL OR DAMAGE TO EQUIPMENT AND PROPERTY litegait com 800 332 WALK 480 829 1727 Please activate your warranty by providing the following information This information will allow us to notify you for product updates recall information clinical support technical support maintenance information and to receive our E Newsletter You may visit our website at http www litegait com warranty html and fill the registration form or fill in the information below and mail or fax back Keep a copy for your records Address Email Write Your Serial Number Here Your serial number will be located on the front of the treadmill motor cover EXAMPLE OF SERIAL NUMBER STICKER 06 00003 082087368
7. Using either the screwdriver or the 3 16 Allen wrench tighten the alignment screw on the front right and of the roller 1 2 turn Check again and repeat if necessary FOR ADDITIONAL ASSISTANCE TROUBLESHOOTING PLEASE FEEL FREE TO CONTACT MOBILITY RESEARCH TECHNICAL SUPPORT 1 800 332 9255 litegait com 800 332 WALK 480 829 1727 12 GaitKeeper Designed for Rehab 6 SPECIFICATIONS Walking Surface Width 18 21 Walking Surface Length 40 40 Treadmill Width 21 24 Treadmill Length 42 42 Foot Print 21 42 24 42 Shipping Weight 6016 7016 Maximum User Weight 350 Incline Range N A Drive Motor Brushless Speed Range 0 1 3 0 Step Up Height 6 Power Requirements 110 240 VAC 50 60 Hz 15 AMP dedicated line Note Dimensions are approximate and are subject to change without notice Authorized European Community Representative Mobility Research Lillehgjvej 29 DK 8600 Silkeborg Denmark litegait com 800 332 WALK 480 829 1727 13 Designed for Rehab 7 RESOURCE DIRECTORY Phone Fax Website Phone LiteGait com 800 332 WALK 9255 LiteGait org Toll free in U S and Canada Fax 480 829 0737 litegait com 800 332 WALK 480 829 1727 2015 US 14 Email Directory Service amp Parts Clinical Support Education Sales Service LiteGait com ClinicalSupport LiteGait com Education LiteGait com
8. alk or jog backwards on the treadmill without the aid of a physician and support from LiteGait litegait com 800 332 WALK 480 829 1727 Designed for Rehab e This equipment should never be left unattended when plugged in Wear shoes with rubber or high traction soles Do not use shoes with heels leather soles cleats or spikes Make sure stones are embedded in the soles Do not use this product in bare feet Keep all loose clothing shoelaces and towels away from moving parts e Do not operate the Walking Surface while being covered with a blanket plastic or anything that insulates or stops airflow e Close supervision is necessary if the Walking Surface is used by children or used near children Also applies to disabled persons e Use this Walking Surface only for its intended use as described in this manual e Do not use attachments not recommended by the manufacturer e Never operate if the power cord or plug is damaged if it is not working properly if it has been damaged or dropped or if it has been submerged in water In these cases a qualified service technician should examine the walking surface e Do not use the power cord as a handle for transporting e Do not run the power cord along the side or under the treadmill e Keep the power cord away from heated surfaces e Never drop or insert any object into any opening e Do not reach into or underneath the unit or tip it
9. d outlet The ground helps prevent electrical damage to your treadmill and enhances your safety by helping to prevent shock Check with a qualified electrician or serviceman if you are in doubt as to whether the treadmill is properly grounded Do not modify the plug provided with the treadmill if it will not fit the outlet Have a proper outlet installed by a qualified electrician Component Checklist ITEM DESCRIPTION Walking Surface Hand Set Magnetic Safety Key Power Cord Walker Style Handlebars litegait com 800 332 WALK 480 829 1727 GaitKeeper ee Designed for Rehab ASSEMBLY INSTRUCTIONS WITH LITEGAIT litegait com 800 332 WALK 480 829 1727 GaitKeeper ee Designed for Rehab litegait com 800 332 WALK 480 829 1727 Designed for Rehab POWER REQUIREMENTS FOR GAITKEEPER PRODUCTS NOTE Read and understand all instructions on this sheet and in the Owner s manual before plugging any power cord into an electrical outlet This informa tion sheet will help you identify the voltage and cords you need where you live and will outline re quirements for Grounded dedicated lines e Voltage Power cords e Power adapters e Extension cords DANGER Improper connection of the equipment grounding conductor can result in risk of electric shock Check with qualified electrician or service provider if you are in doubt as to whether the equipment is prop
10. erly grounded or installed on a dedicated line Seek qualified electrician to perform any modifications to the cord or plug Mobility Research is not responsible for any injuries or damages as a result of cord or plug modification CAUTION Place cords away from heat such as baseboards Use care to arrange any cord so it does not become an obstacle Extension Cords Do not use an extension cord to supply power to any product GaitkKeeper equipment must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock GaitKeeper cords except for cycle adapters have an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances where you live Do not use a ground plug adapter to adapt the power cord to a non grounded outlet Do not use a GFCI outlet GFCI circuit breaker A dedicated line will assure that adequate power is available for safe operation over the life of your GaitKeeper Product litegait com 800 332 WALK 480 829 1727 Voltage Voltage required for your unit is located on the serial number decal usually on the front of the unit Depending on where you live voltage requirements differ 115 115V Euro Plug 208 220V NEMA 5 15 NEMA 5 20 7 7 NEMA 6
11. her indications that the equipment may be in need of service If you notice any of these obtain service IMPORTANT If you determine that the Walking Surface needs service make sure that the Walking Surface cannot be used inadvertently Remove the magnet to power the device down and let users know service is needed CLEANING THE EQUIPMENT MOBILITY RESEARCH recommends the walking surface be cleaned before and after each workout Use mild soap and water to dampen a soft cloth and wipe all exposed surfaces This helps remove any dust or dirt CAUTION Do not use any acidic cleaners Doing so will weaken the paint or powder coatings and may void the Warranty Never pour water or spray liquids on any part of the device Allow the walking surface to dry completely before using Frequently vacuum the floor underneath the unit to prevent the accumulation of dust and dirt which can affect the smooth operation of the unit When cleaning the exterior of the unit a non abrasive cleaner and soft cotton cloth are strongly recommended At no time should cleaner be applied directly to any part of the equipment use nonabrasive cleaner of soft cloth and then wipe the unit LONG TERM STORAGE When the treadmill is not in use for any length of time ensure the power cord is unplugged from the power source and position the power and data cords so that they will not become damaged or interfere with people or other equipment litegait com 800 332 WALK 480 82
12. on its side during operation e Use indoors only e Do not operate where aerosol spray products are being used or where oxygen is being administered e Allow only trained personnel to service this equipment e Never use near water or while wet Using this Walking Surface around a pool hot tub or sauna will void the warranty e Avoid the possibility of bystanders being struck or caught between moving parts by making sure that they are out of reach of the walking surface while it is in operation e Allow only one person at a time on the Walking Surface while it s operating e that the sides of the treadmill are placed at least 20 away from wall or other obstructions e Never place liquids of any type directly on the unit e Do not allow animals on or near the treadmill while it s operating e Consult your physician before beginning any exercise program e Do not use if you have a cold or fever litegait com 800 332 WALK 480 829 1727 Designed for Rehab 3 OPERATION OPERATION Treadmill Use Preparation Attach magnetic safety key lanyard to LiteGait Connect magnetic safety key to Walking Surface Operation Stand carefully on the walking belt while supported by LiteGait Press the button on the handset The walking belt will start at the speed it was running when the button was last pressed or at 0 1 kph if the walking surface has been powered down