1. Compact Digital Links via an IR Amplifier such as a Triax Link Amplifier Fig 3 Application Diagram Connect A V signal source port to A V Input on the modulator with RCA connector cable Connect A V Output of the modulator to A V Input on TV like device set with RCA connector cable A V signals can be transferred from A V Output of the modulator to A V input of TV set Plug the provided power adapter into DC Power Input of the modulator Connect local cable TV or other signal source to RF IN of the modulator with RF cable The A V signal from A V Input is modulated as the RF signal combined and amplified with the RF signal from RF IN then output via RF 1 OUT and or RF 2 OUT of modulator Connect RF 1 OUT of the modulator to the main TV set in the lounge to watch programs Connect RF 2 OUT to a spare room TV set through an additional RF cable and Digital Link Eye optional Note RF2 OUT IS WITH 9VDC voltage Do not connect RF2 OUT to TV set directly without Digital Link Eye Plug the IR transmitter into IR jack on the modulator Adjust the IR sensor toward the A V signal source for an optimum reception Operating Instruction Make sure the power adapter is connected to DC IN of the modulator Turn the power switch to ON then the CH number on Display Screen lights up There is 10 10dB adjustable gain from RF IN to RF1 OUT and RF2 OUT When the power is on the signal from RF IN can output to RF1 OUT and RF2 OUT
2. p 6000 Output Connector 3 Kit Content Modulator x1 Power Adapter 9VDC 600mA x1 User s Manual x __ __ lt C 5 5 2 1 DC Plug 4 Installation and Operating Instruction i Panel Function IR Transmitter Jack 3 5mm mono phone plug DC Power Input 9V DC Power Switch RF Input This port can output 7 2MHz remote signal RF Output 1 RF Output 2 This port output 9Vdc and input 7 2MHz remote signal Gain control Rotate this component can control the gain from RF input port to RF1 output and RF2 output port N o c FP c NN 8 A V Input RCA Socket include one video input port and two audio input ports 9 A V Output RCA Socket include one video output port and two audio output ports 2 3 4 5 6 10 Display Screen It can display CH number and audio carrier frequency 11 Mode Switch This button can switch between PAL G and PAL I system 5 5 means PAL G system and 6 0 means PAL I system 12 Channel Down Switch 13 Channel Up Switch 10 11 12 13 Installation Plasma LCD with 4 Feeview Aerial RF 1 OUT RF IN RF 2 OUT DC IN 9V 600mA Freesat rad Receiver gt a TV2 IR Sensors 6 ME lt a 370228 e RF 2 OUT can either go direct to the Triax Compact Digital Link or via a suitable wall plate If more than one additional TV is required then RF 2 OUT is connected to the
3. same channel Intermittence of Image and Sound e Make sure the modulation and TV are using the free channel e Shorten the distance of the signal transmission medium between modulator and TV keep the coaxial cable away from other cables if possible 9 6 Frequency Table Frequency Frequency Frequency 33 seras 49 60525 65 82325 34 57526 so 70325 66 83125 35 56325 51 TM25 67 83925 36 68 51 591 25 52 719 25 847 25 a a ME B 471 25 599 25 727 25 E 29 535 25 45 663 25 61 791 25 30 543 25 46 671 25 62 799 25 33 9 5 10
4. without additional amplifier Use Channel Selection Switches to select the desired channel Push the up or down button firmly the CH will be changed continuously then release the button until the CH stopping at your favor When the A V signal from A V signal source is fed to the modulator there will be the modulated signal output from the modulator There won t be any modulated signal output without A V signal input 8 5 Use the mode switch to change TV system two figures will display on Display Screen 5 5 or 6 0 and 5 5 means audio carrier frequency is 5 5MHz PAL G system Whereas 6 0 stands audio carrier frequency is 6 0MHz PAL I system Pushing CH switch or holding with no operation after one minute will exit mode state To watch the local cable TV programs from RF IN the A V signal from DVD or Satellite Receiver must be turned off With A V signal source remote controller aiming to the IR sensor of Digital Link Eye the controlling signal transmits through the RF cable to the modulator then outputs by IR transmitter to control the A V signal source And if your signal source is SKY satellite receiver it can be controlled without IR transmitter because its signal directly runs from RF output to RF Input on modulator 5 Troubleshooting No Image or Sound e Make sure the power switch is switched to ON position Check the connections of all connectors and plugs e Make sure the modulation and TV are tuned to the
5. TRIAX DECLARATION OF CONFORMITY TRIAX confirms that the product conforms to relevant EMC and LVD Directives 2004 108 EC and 2006 95 EC harmonized standards and consequently can carry CE mark Relevant harmonized standards EMC EN 55013 2001 A1 2003 A2 2006 EN 55020 2007 A11 2011 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 LVD EN 60065 2002 A1 2006 A11 2008 A2 2010 A12 2011 KONFORMITATSERKLARUNG TRIAX bestatigt dass das Produkt die EMC und LVD Richtlinien 2004 108 EC und 2006 95 EC der harmonisierten Normen erfullt und folglich das CE Zeichen tragen darf Relevante harmonisierten Normen EMC EN 55013 2001 A1 2003 A2 2006 EN 55020 2007 A11 2011 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 LVD EN 60065 2002 A1 2006 A11 2008 A2 2010 A12 2011 OVERENSSTEMMELSESERKL ERING TRIAX bekreefter at dette produkt opfylder de relevante EMC og LVD direktiver 2004 108 EF og 2006 95 EF og harmoniserede standarder og dermed kan baere CE meerket Relevante harmoniserede standarder EMC EN 55013 2001 A1 2003 A2 2006 EN 55020 2007 A11 2011 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 THIAX User manual TFM 02 TRIAX IR link modulator TABLE OF CONTENTS PAGE 1 Safety Precaution T Safety PIECAUNON search ene 2 e To avoid electrical shock do not take apart this device E 3 e This device should use only the power supply included with it or provided as an accessory 2 Tech
6. nical specification EM reu M u 4 e Do not overload wall outlets and extension cords as this can result in the risk of fire or electrical shock 4 Installation and Operating Instruction 5 8 e Do not attempt to service this device yourself Refer servicing to qualified personnel only 5 Troubleshooting euere 9 6 Frequency Table cessere nnne nnn 10 Caution Changes or modifications not expressly approved by the Party responsible for compliance could void the user s authority to operate the equipment 2 Technical Specification ITEM DESCRIPTION CH Indicator Two Bit 7 segment LED Modulator DC Output RF2 Regulated 9VDC 100mA TV System PAL G Power Adapter Modulator Output Frequency mu en 2 See ponant Input Voltage 100 240V 50 60Hz AC Modulator Output Level on Suguh vieles 9V 600mA DC RF1 RF2 OUT Gain RF IN RF1 RF2 OUT Return Path Gain 4MHz 8MHz Carrier Noise Ratio Noise Figure Maximum Output Level 60dB IMA3 EN50083 5 RF Input Connector RF Output Connectors AV Input Output Connectors DC IN Connector IR Connector IR Link Control Carrier Frequency RF2 OUT to RF IN Video Input Audio Input 72 dBuV 4dB 10 10dB Adjustable gt 10 dB Peak Point 18dB 2dB gt 48 dB lt 4dB 90dBuV F f F f RCA Port 5 5 2 1 Socket 3 5mm Socket On off keyed 7 2MHz 1 0Vp p 75 9 1 0Vp