Home

Setup Procedure UTAdvanced Quick Setting (Controlling Tank Level

image

Contents

1. 2 Press SET ENTER the setting value blinks 3 Change the setting with the UP or DOWN key 4 Press SET ENTER to set the new value the setting value stops blinking but remains Once functions are configured with the Quick Setting the Quick Setting function bright Power e Redoing the Quick Setting will not appear after you restart However you can redo the Quick Setting by Quick Setting following the procedure below start 1 Set the Quick Setting parameter QSM to ON and re engage power 3 2 Set the PV input type parameter IN to OFF and re engage power 4 START QUICK Press SET ENTER to accept the YES option SETTING Quick Setting starts y CONTROL TYPE First the control type parameter CNT appears Set CNT control type to ONOF2 initial value N BT m 3 OFF is displayed for IN the PV input type aN 4 Ne TEE Set IN PV input type to current signal 4 20 4 20 4 00 to 20 00 mA ZAA 5 PV INPUT UNIT Set UNIT PV input unit to none If necessary use the unit label m This document is subject to change without notice TI 04L01L01 05EN 2011 12 16 00 3 4 MAXIMUM Set RH maximum value of PV input range to 20 00 mA initial value 6 VALUE OF PV INPUT RANGE 7 OA UE OF oe Set RL minimum value of PV input range to 4 00 mA initial value INPUT RANG PV INPUT SCALE DECIMA 8 KONIAKU Set SDP PV input scale decimal point position to 2 9 MA
2. Technical Setup Procedure Information UTAdvanced Quick Setting Controlling Tank Level ON OFF TI 04L01L01 O5EN Foreword O The contents of this document are subject to change without prior notice as a result of improvements in performance or functionality O Copying or reproduction by any means of all or any part of the contents of this document without permission is strictly prohibited O Use of this document is at the users risk m Overview This is an example of wiring and settings using the UTAdvanced Quick Setting function for tank level ON OFF control For more details see the user s manual m Relevant models Standard models of the UT32A UT35A and UT55A with the 24 VDC sensor power supply option m System Close the valve on or over the set value Close Current signal Relay output A 4 20 mA transmitter SP power supply m Wiring UT32A LP UT35A LP UT52A LP UT55A LP Current input Current input 4 20 mA 4 20 mA PV Current PV Current input input 6 Transmitter power supply 24 VDC 21 6 28 0 VDC Level transmitter Level transmitter Transmitter power supply 24 VDC 21 6 28 0 VDC Relay output YOKOGAWA This document is subject to change without notice TI04L01L01 05EN 2011 12 16 1st Edition YK 2 4 m Settings To set ON OFF control input signal 4 to 20 mA and relay control output set the following parameters 1 Select the desired parameter with the UP or DOWN key
3. XIMUM VALUE OF PV INPUT SCALE Set SH maximum value of PV input scale to 3 00 3 0 m 10 a aa Set SL minimum value of PV input scale to 0 00 0 00 m 44 SUPUT vee Set OT output type selection to 00 03 OUT terminal control relay SELECTION 12 CONTROL OUTPUT Skip this parameter not relevant Meee CYCLE TIME 13 BAND Finally EXIT is displayed Select YES and press SET ENTER to complete the basic function setup and return to the operating screen Or you can select NO to continue with the Quick Setting This document is subject to change without notice TI 04L01L01 05EN 2011 12 16 00 4 4 Revision Information Document name Setup Procedure UTAdvanced Quick Setting Controlling Tank Level ON OFF Document number TI 04L01L01 O5EN First edition December 2011 Newly released This document is subject to change without notice TI O4L01L01 O5EN 2011 12 16 00

Download Pdf Manuals

image

Related Search

Related Contents

Samsung Samsung S5600 Kasutusjuhend  Bedienungsanleitung - WilTec Wildanger Technik  MS-Tech MC-1200SI computer case  StarTech.com 4 Bay eSATA USB 2.0 to SATA Hard Drive Docking Station  Fujitsu ESPRIMO P920  und LU6.2-Anwendungen - Fujitsu manual server  η αποδελτιωση των τευχων του contact εγινε απο την μαρια  Cellular Line CRABSUPERGIPHONE holder  Smeg MF22-CR faucet  

Copyright © All rights reserved.
Failed to retrieve file