Home

F Series Indoor IP User`s Manua

image

Contents

1. Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment This series network camera should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Please keep it away from the electromagnetic radiation object and environment Please make sure the CCD CMOS component is out of the radiation of the laser beam device Otherwise it may result in CCD CMOS optical component damage Please keep the sound ventilation Do not allow the water and other liquid falling into the camera Thunder proof device is recommended to be adopted to better prevent thunder The grounding studs of the product are recommended to be grounded to further enhance the reliability of the camera 6 Daily Maintenance Please shut down the device and then unplug the power cable before you begin daily maintenance work il Do not touch the CCD CMOS optic component You can use the blower to clean the dust on the lens surface Always use the dry soft cloth to clean the device If there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device Please put the dustproof cap to protect the CCD CMOS component when you do not use the camera Dome enclosure is
2. then paste it on the ceiling or the wall according to your monitor area requirements Step 3 Draw and then dig three plastic expansion bolts holes on ceiling or other installation surface and then insert three expansion bolts in the holes Secure these three bolts firmly Note Please dig a cable exit hole in the surface according to the installation position map if you want to draw out the cable from the top of the installation surface You need to use the proper tool to open up the side port of the U cable channel of the dome camera pedestal if you want to draw out the cable from the side port of the cable channel when you are installing the device cable And then you can draw out the cable from the cable channel of the pedestal Step 4 Adjust the device installation pedestal to the proper position and then draw the cable through the cable exit you just dug in the ceiling wall Line up the TOP direction of the device to the installation position map and then line up the three screw holes in the device pedestal to the three plastic expansion bolt holes in the installation position Put the three self tapping screws in the three plastic expansion bolts firmly Now the dome camera is secure in the installation surface Step 5 Loosen the two M3 secure screws of the lens rotation structure Do not remove loosen a little bit will be OK Use the inner hexagonal wrench to insert them to the inner hexagonal holes and then use the wren
3. Mini Network Dome Camera User s Manual Version 4 3 1 Welcome Thank you for purchasing our network camera This user s manual is designed to be a reference tool for your system Please read the following safeguard and warnings carefully before you use this series product Please keep this user s manual well for future reference Important Safeguards and Warnings 1 Electrical safety All installation and operation here should conform to your local electrical safety codes The power shall conform to the reguirement in the SELV Safety Extra Low Voltage and the Limited power source is rated 12V DC or 24V AC in the IEC60950 1 Refer to general introduction Please note Do not connect these two power supplying sources to the device at the same time it may result in device damage The product must be grounded to reduce the risk of electronic shock We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation We are not liable for any problems caused by unauthorized modification or attempted repair 2 Transportation security Heavy stress violent vibration or water splash are not allowed during transportation storage and installation 3 Installation Do not apply power to the camera before completing installation Please install the proper power cut off device during the installation connection Always follow the instruction guide the manufacturer recommended 4
4. P addresses in the same segment 4 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc Device List SN IP Address Port Subnet Mask Default Gateway Mac Address 1 192 168 1 108 3TTTT 255 255 255 0 192 168 1 1 90 02 a9 7b 50 gal m gt Tip You can click login button directly and then input corresponding information in fa Upgrade Refresh Login Logout Figure 4 1 Search interface Select one IP address and then right click mouse you can see an interface is shown as in Figure 4 2 Select the Open Device Web item you can go to the corresponding web login interface Device List SN IP Address Port Subnet Mask i 255 255 0 lt l NR Tip You can click login button directly and then input corresponding information to login fil Upgrade Refresh Login Logout Figure 4 2 Search interface 2 If you want to modify the device IP address without logging in the device web interface you can go to the configuration tool main interface to set 11 In the configuration tool search interface Figure 4 1 please select a device IP address and then double click it to open the login interface Or you can select an IP address and then click the Login button to go to the login interface Se
5. ch to turn the lens Adjust the lens to the proper monitor angle and then secure the screws of the lens rotation structure The lens adjust angle ranges are flip 0 75 video pan rotation 15 15 video rotation angle 15 15 Step 6 Line up the dome camera cover to the cable exits and put the cover back Use the inner hexagonal wrench to secure the three inner hexagonal screws firmly Now the installation completed Note The device GND cable can effectively enhance the device reliability The GND hole is near the cable exit of the back of the enclosure The GND screw specification is M3 See Figure 3 3 Figure 3 3 Device installation illustration 3 3 2 Micro SD Card Installation Important Some series products do not support the Micro SD card storage function Please shut down the power and then turn off the device before you install the Micro SD card Step 1 Please refer to the step 1 in chapter 3 1 to open the device Step 2 Find the Micro SD CARD indicator in the enclosure Adjust the Micro SD card to the proper direction and then install See Figure 3 4 Step 3 Please refer to the step 6 in chapter 3 1 to complete the installation Figure 3 4 Device installation illustration 4 4 Quick Configuration Tool 4 1 Overview Quick configuration tool can search current IP address modify IP address At the same time you can use it to upgrade the device Please note the tool only applies to the I
6. ctivation setup and exert corresponding message in screen and audio prompt allow user to pre Alarm record audio file Function Real time video detect motion detect camera masking e Can generate an alarm when network abnormal Micro SD card abnormal event occurred Network camera supports one channel video data transmit to network terminal and then decode Delay is within 270ms network bandwidth support needed aie e Max supports 20 connections l Adopt the following audio and video transmission protocol HTTP TCP UDP RTP RTCP RTSP and etc e Support web access widely used in WAN N Realize network camera configuration and management via Ethernet etwork 1 a Management e Support device management via web or client end Support various network protocols External power adapter DC12V e Support PoE Power Warning Do not connect these two power supplying sources to the device at the same time it may result in device damage e Log function Assistant e Day Night mode auto switch Function e Backlight compensation screen auto split to realize backlight compensation to adjust the bright Support digital WDR Support system resource information and running status real time display Support video watermark function to avoid vicious video modification Support electronic shutter and gain setup Support dual bit stream support ACF 1 3 Specifications 1 3 1 Performance Please refer to t
7. e Figure 4 3 In Figure 4 3 you can view device IP address user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you cannot login the device If you are using device background upgrade port 3800 to login other setups are all invalid IP Address 192 168 1 108 User Name admini Password Port 37777 Figure 4 3 Login prompt After you logged in the configuration tool main interface is shown as below See Figure 4 4 NetWork Paraneter PPPOE System Information System Upgrade General Parameter 7 DHCP Enable iva IP Address 192 168 1 108 Subnet Mask 255 255 0 0 Gateway 10 15 0 1 Mac Address 90 02 39 7F d8 21 Figure 4 4 Main interface For detailed information and operation instruction of the guick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD 12 5 Web Operation This series network camera products support the Web access and management via PC Web includes several modules Monitor channel preview system configuration alarm and etc 5 1 Network Connection Please follow the steps listed below for network connection Make sure the network camera has connected to the network properly Please set the IP address subnet mask a
8. g 2 Framework 2 1 Structure Please refer to the following figure for detailed information See Figure 2 1 Figure 2 1 Structure Please refer to the following sheet for detailed structure information Name X Y Z rotation module 3 Dome camera enclosure Please refer to the following sheet for detailed port information Name Function SN Connect to the DC 12 power to Power input port input ihe power p Network port oo data input output and 2 2 Dimensions Please refer to the following figure for the dimension information The unit is mm See Figure 2 2 through Figure 2 4 Figure 2 2 Dimension illustration 1 Figure 2 3 Dimension illustration 2 Figure 2 4 Dimension illustration 3 3 Installation 3 1 Device Installation Important Please make sure the installation surface can min support the 3X weight of the camera and the bracket Please refer to the steps listed below Ceiling or wall Expansion bolt Dome camera body ST3 self tapping screws Dome camera enclosure Enclosure secure screws Figure 3 1 Device installation illustration 1 Inner hexagonal wrench Figure 3 2 Device installation illustration 2 Step1 Use the inner hexagonal wrench provided to loose the three inner hexagon screws in the dome cover and then open the cover Step 2 Please take the installation position map in the accessories bag and
9. he following sheet for network camera performance specification Model Main High performance DSP Processor OS Embedded LINUX System Support real time network local record and remote operation at the Resources same time User Interface Remote operation interface such as WEB DSS PSS System Status SD card status bit stream statistics log and software version inch CMOS Piei 2048 H 15360 Day Night Support day night mode switch Gain Control Fixed Auto White Balance Manual Auto BLC Off BLC WDR 1 100 HLC anti flicker is outdoor and is valid only when J9 9UEJEJ O9PIA exposure mode is auto with range 1 100 Electronic Manual Auto Shutter It ranges from 1 3 to 1 100000 Video Compression H 264 H 264H MJPEG Standard PAL Main stream 2048 1536 20fps Extra stream 1 704 576 20fps Extra stream 2 1280 720 1fps Main stream 1920 1080 25fps Extra stream 1 704 576 25fps Extra stream 2 1280 720 11fps NTSC Main stream 2048 1536 20fps Extra stream 1 704 480 20fps Extra stream 2 1280 720 1fps Video Frame Rate Main stream 1920 1080 30fps Extra stream 1 704 480 30fps Extra stream 2 1280 720 1fps Note Extra stream 2 s actual frame depends on max capacity set which can be adjusted within its range H 264H 40Kbps 8192Kbps adjustable MIN ahs Rale MJPEG 40Kbps 16384Kbps adjustable and bit rate is adjustable J9JQUIBJ1eg e 19uar Support cu
10. nd gateway of the PC and the network camera respectively Network camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 e Use order ping network camera address to check connection is OK or not 5 2 Login and Main Interface Open IE and input network camera address in the address bar See Figure 5 1 Blank Page Windows Internet Explorer aboutiblank e Input your IP gt address here Internet R100 Figure 5 1 IP address The login interface is shown as below See Figure 5 2 Please input your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you first login 13 IP Camera Username Password Figure 5 2 Web login After you successfully logged in please install WEB plug in unit Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction See Figure 5 3 IP Camera Po uve emo o setup Alamo o Logout Protocol HEN q LA XO Figure 5 3 Web monitoring window 14 I can not boot up Please click RESET button for at least five seconds to restore the device factory default setup Micro SD card Do not set the Micro SD card as the storage media to storage the write times schedule record file It may damage the Micro SD card duration can
11. not use the When disk information is shown as hibernation or capacity is 0 disk as the storage please format it first Via Web media I can not upgrade the device via network When network upgrade operation failed you can use port 3800 to continue upgrade Recommended Kingston 4GB Kingston 1GB Kingston 16GB Transcend 16GB Micro SD card SanDisk 1G SanDisk 4G brand Usually we recommend the 4GB or higher or industry level high speed card in case the slow speed results in data loss Save setup Please use active device for the audio monitor input otherwise there is no audio in the client end Power adapter General power adapter work temperature ranges from 0 C to 40 C It may result in unstable performance if it works in the extremely too hot or too cold environments In this case you may need to use the industrial level power adapter 15 Appendix Toxic or Hazardous Materials or Elements Component Name Toxic or Hazardous Materials or Elements Pb Hg Cd Cr VI PBB PBDE Circuit Board Component Device Construction Material Wire and Cable Packing Components Accessories O Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance of at least
12. one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your local government statutes Note e This user s manual is for reference only Slight difference may be found in user interface e All the designs and software here are subject to change without prior written notice e If there is any uncertainty or controversy please refer to the final explanation of us e Please visit our website for more information 16
13. stomized setup E Support mirror function Alo Flip Support flip function Snapshot Max 1f s snapshot File extension name is JPEG Privacy Mask Supports max 4 privacy mask zones Interest Area Support max 4 interest areas Video Setup Support parameter setup such as bright contrast MES A Channel title time title motion detect privacy mask overlay Information Lens 2 8mm fixed focus M12 Lens is the default accessories Lens Interface 396 18 22 detection zones sensitivity level ranges from 0 to 100 area threshold ranges from 0 to 100 Activation event video storage image snapshot log email function and etc Video Loss A ekigo event video storage image snapshot log email function and kerato Manual Video detect gt Schedule riority Local Storage Support Micro SD 64GB card storage NAS storage Motion Detect Wire Network 1 channel wire Ethernet port 10 100 Base T Ethernet Standard HTTP TCP IP IPv4 IPv6 ARP IGMP ICMP RTSP RTP UDP SMTP FTP DHCP DNS DDNS PPPOE UPNP NTP Bonjour SNMP QoS 802 1x Network Protocol Platform interface PSIA ONVIF Standard Remote A i A Monitor system setup log information maintenance upgrade and etc Built in RESET button Support DC12V and PoE Note 05 series does not support PoE Power Working Da Working A Humidify 998 Dimensions m 110x54 0 25Kg Installation Installed in the places such as wall or the ceilin
14. the optical component do not touch the enclosure when you are installing the device or clean the enclosure when you are doing maintenance work Please use professional optical clean method to clean the enclosure Improper enclosure clean method such as use cloth may result in poor IR effect of camera with IR function 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation please open the package and check all the components are included Contact your local retailer ASAP if something is broken in your package Accessory Name Amount Network Camera Unit 1 Installation Accessories bag 1 Quick Start Guide 1 CD 1 ill li General IMraduclionisssst a oke el ni iii ele 1 1 1 OVEME Mi shell ale ele 1 1 2 Sis Vi SIR RR a tan 1 1 3 SDECIIICANONS sattumist 2 BITS 2 2 EKAMGWOK ra a e ka E SS IN E ETR 4 2 1 A USERS a ms E 4 2 2 DIMENSION SO a e RV ak nus 4 si MA MAMA LkEoo ne ee OS elio 7 3 1 DEVICE station SS naa 7 3 2 Micro SD Card Installation aa E E I 9 4 Quick Configuration Fool a a ein a a aea aa 11 4 1 Venere a e nm 11 42 OPE MIN ata Md mullu 11 br WED ODM oi 13 5 1 Network Connections iiien ts 13 5 2 EOOMNaINO Mal ME ACE a oinline o ai 13 Sy Pilati 15 Appendix Toxic or Hazardous Materials or Elements emetremreneneme nen 16 Table of Contents 1 General Introduction 1 1 Overview This series ne
15. twork camera integrates the traditional camera and network video technology It adopts audio and video data collection transmission together It can connect to the network directly without any auxiliary device This series network camera uses standard H 264 video compression technology and MJPEG audio compression technology which maximally guarantee the audio and video quality This series network camera enclosure has the strong resistance capacity which can guarantee the proper work performance under heavy strike It supports real time monitor and motion detect function It can be used alone or used in a network area When it is used lonely you can connect it to the network and then use a network client end Due to its multiple functions and various uses this series network camera is widely used in many environments such office bank road monitor and etc 1 2 Features User e Different user rights for each group one user belongs to one group The user right shall not exceed the group right Management e Support central server backup function in accordance with your configuration and setup in schedule setting Storage e p ppor record via Web and the recorded file are storage in the client end Function e Support built in Micro SD card Support short time storage when encounter disconnection For some series only Support network storage such as FTP Real time respond to video detect as user pre defined a

Download Pdf Manuals