1. Symbols Symbols Table 1 shows the symbols used in this manual or on the Product Table 1 Symbols Symbol Explanation A Risk of danger Important information Refer to manual A Hazardous voltage Risk of electric shock Application and removal from hazardous live conductors permitted n Double insulated Low battery 4 Earth ground gt Alternating current Direct current Do not dispose of this product as unsorted municipal I waste Go to Fluke s website for recycling information Conforms to relevant European Union directives Equipment is designed to protect against transients CAT III in equipment in fixed installations such as distribution panels feeders and short branch circuits and lighing systems in large buildings 317 319 Users Manual Specifications General Specifications Digital Display Low Battery Indication Power Source Clamp Opening Size Jaw Diameter Display Resolution Auto Range 6000 count resolution Shows when the batteries are below their required voltage Three AAA IEC LRO3 batteries 37 mm 1 45 in 37 mm 1 45 in 162 4 x 58 25 x 30 5 mm 6 39 x 2 29 x 1 20 in Approximately 384 g 13 5 oz batteries included 6000 Counts Available in Ohms CE EN IEC 61010 1 and IEC 61010 2 032 600 V CAT III Electrical Specifications The accuracy specification is defined as reading digits at 23 5 Clamp Meter S
2. REP 1 How to Contact 1 1 Safety Information eene 2 ecce 5 Specifications 6 General 6 Electrical Specifications 7 Software Specifications 10 Environmental Specifications 10 The Product iii ien dere eet 11 317 319 Users Manual Clamp Meter Introduction The Fluke 317 and 319 are hand held battery operated clamp meters the Product that measure ac and dc current ac and dc voltage resistance continuity frequency The Product ships with test leads soft case three AAA batteries installed 317 319 User Manual How to Contact Fluke To contact Fluke call one of these telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 3 6714 3114 Singapore 65 738 5655 Anywhere in the world 1 425 446 5500 317 319 Users Manual Or visit Fluke s website at www fluke com To register your product visit http register fluke com To view print or download the latest manual supplement visit http us fluke com usen support manuals Safety Information
3. AAWarning To prevent possible electrical shock fire or personal injury Use the Product only as specified or the protection supplied by the Product can be compromised Limit operation to the specified measurement category voltage or amperage ratings Do not touch voltages gt 30 V ac rms 42 V ac peak or 60 V dc Carefully read all instructions Do not exceed the Measurement Category CAT rating of the lowest rated individual component of a Product probe or accessory Do not use the Product around explosive gas vapor or in damp or wet environments Use only correct measurement category CAT voltage and amperage rated probes test leads and adapters for the measurement Do not work alone Clamp Meter Safety Information Do not apply more than the rated voltage between the terminals or between each terminal and earth ground Comply with local and national safety codes Use personal protective equipment approved rubber gloves face protection and flame resistant clothes to prevent shock and arc blast injury where hazardous live conductors are exposed Replace the batteries when the low battery indicator shows to prevent incorrect measurements Keep fingers behind the finger guards on the probes Measure a known voltage first to make sure that the Product operates correctly Do not use and disable the Product if it is damaged Connect the common test lead before the live test lead and re
4. 317 319 Clamp Meter PN 4092877 September 2011 2011 Fluke Corporation All rights reserved Specifications subject to change without notice All product names are trademarks of their respective companies LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Fluke Corporation Fluke Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands 11 99 Table of Contents Title Page
5. move the live test lead before the common test lead Read all safety Information before you use the Product Remove all probes test leads and accessories that are not necessary for the measurement Before each use examine the Product Look for cracks or missing pieces of the clamp housing or output cable insulation Also look for loose or weakened components Carefully examine the insulation around the jaws 317 319 Users Manual Do not use test leads if they are damaged Examine the test leads for damaged insulation exposed metal or if the wear indicator shows Check test lead continuity Disconnect power and discharge all high voltage capacitors before you measure resistance continuity capacitance or a diode junction Do not hold the Product anywhere above the tactile barrier See Figure 1 Do not use the current sensor if the wear indicator in the jaw opening is not visible See Figure 2 For safe operation and maintenance of the product Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period Be sure that the battery polarity is correct to prevent battery leakage Repair the Product before use if the battery leaks Have an approved technician repair the Product Remove the input signals before you clean the Product Do not operate the Product with covers removed or the case open Hazardous voltage exposure is possible Clamp Meter
6. pecifications Function Parameter a7 39 Range Resolution Accuracy Crest factor add 2 into spec for CF sp 1 6 6 digit 50 60 Hz 40 A 2 5 8 digit 60 500 Hz 40 A 1 5 5 digit 50 60 Hz 600 A 2 5 5 digit 60 500 Hz 600 A 3 0 Max 500A 2 5 Max 600A AC rms rms response 7 1 6 6 digit 50 60 Hz 40 A 2 5 8 digit 60 500 Hz 40 A 1 5 5 digit 50 60 Hz 600 1000 A 2 5 5 digit 60 500 Hz 600 1000 A 3 0 Max 500 A 2 5 600 1 4 Max 1000A 317 319 Users Manual Function Parameter me Range 40 00A 600 0A Resolution 0 01A 0 1A Accuracy 1 6 6 digit 1 6 6 digit 40 A 40 A 1 5 5 digit 1 5 5 digit 600 A 600 1000 A 1 5 5 digit 20 500 Hz response Range 400 0 0 4000 Q Resolution 0 10 10 me Inrush Integration fos rm e Clamp Meter 2 5 5 0 500 0 Hz Parameter 10 100 Hz 25 A Trigger 5 10 Hz Level 100 500 Hz 210A The accuracy specifications apply at 23 C 5 73 F 41 F Below 18 C and above 28 C 64 F and above 82 F accuracy degrades at 0 1 times specification per C True rms for ac V and ac A accuracy is specified from 5 to 100 of range 317 319 Users Manual Software Specifications Calibration nns Full manual calibration and test One year calibration cycle Data Integrity and Security Calib
7. ration parameters stored in flash ROM Environmental Specifications Operating Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 40 C to 60 C 40 F to 140 F Operating Humidity Non condensing 10 C 50 F 90 RH 50 F to 86 F 10 C to 30 C 75 RH 86 F to 104 F 30 C to 40 C 45 RH 104 F to 122 F 40 C to 50 C Without Condensation Operating Altitude 2000 meters 1 mile above mean sea level Storage Altitude 12 000 meter 7 miles above mean sea level IP Rating com IP40 Vibration Requirements Random MIL PRF 28800F Class 2 5 500 Hz 30 minutes per axis Drop Test Requirements 3 ft 1 m drop test six sides oak floor EMI RFI EMC Instrument unspecified for use in EMC field 20 1 V m 10 The Product 1 ClampMeter Pr BBBB Soo FLUKE 319 TRUE AMS CLAMP METER Clamp Meter The Product Tactile Barrier etr111 eps 11 317 319 Users Manual 2 Jaw Wear Jaw Wear Indicator etr113 eps 12 Clamp Meter The Product 1 I I I 1 I I I I I I I I 1 etr114 eps 13 317 319 Users Manual etr116 eps 14 7 Displa
8. y Hold 8 MIN MAX AVG 2300 ame FLUKE 319 Clamp Meter The Product 2 sec Exit etr122 eps 15 317 319 Users Manual 9 INRUSH 317 319 Users Manual 18
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi PC Shape Pro Manual Profil de novembre 2013 Kingston Technology ValueRAM DDR2 667MHz 4GB-kit Manual de instruções 1.1 Description Les FLOODSAX sont des sacs innovants, ultra Laura Ashley PXY202 Use and Care Manual 取扱説明書 - ジョンソン・エンド・ジョンソン Chapter 3 - AutomationDirect Copyright © All rights reserved.