1. 3 4 Touch Buttons There four touch buttons under the Digital display displays ENTER UP DOWN ESC Press ENTER to choose the run modes Press Up Down to scroll in the menu or submenu options Press Enter to confirm your selection or to switch between two submenus Any time press and hold Up or Down the value will rapidly change and stop when release Once the value is set it will be automatically saved press ESC to exit Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all Parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the unit operates i e smoke fog residue dust dew Trouble Shooting Listed below are solutions for a few common problems the user may encounter Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Unit does not respond to sound Quiet or Low pitched sounds will not activate the unit If problems are not resolved contact your dealer for service Note All information is subject to change with
2. SL3421 36pcs X3W High Power LED Par 64 User Manual Please read this user manual before your operating the device Safety Introduction Be sure the voltage is not higher or lower than the recommended rating Be sure the power cable has no damage t must be turned off while the unit is not in use or before cleaning it Attention Taking care of the unit while installing avoiding to touch the exposed power line otherwise it will result terrible electric shock Do not look straight at the face of the High Power LED Par 64 light The High Power LED Par 64 light should be far away from children and avoid non professional operation Operation Stipulation The High Power LED Par 64 light can only use indoors Please pay attention to the installation and do not swing the High Power LED Par 64 lights while using it Please be sure the High Power LED Par 64 lights is positioned in the right place no too hot or damp before installing it 1m distance above needed between the High Power LED Par 64 light and the object illuminated Please use appropriate and safe power line to connect the LED Please be sure to familiar with the High Power LED Par 64 light functions before operating since damage may be caused with improper use Please do not modify the lamp any un authorized or un professional operation is not guaranteed by the factory any breakdown and damage the factory has no obligation for maintenance Sp
3. ecifications Power input AC240V 50Hz Light Source 36PCS High Power 3W LED Red12pcs Green12pcs and Blue12pcs Using multi media gradation adjusting technology DMX controls colour dimmer and strobe It has electronic address code setting Digital PAR Light has 360 degrees installation due to specially design of hanging device Shining component 36PCS High Power 3W LED Color RGB Mixed color it has more than 16 777 216 kinds of color changing Basic Color Red Green Blue basic colors DMX Channel 6CH Dimmer Streamline dimmer adjustment Connecting 1 If using the Par lights separately each High Power LED Par 64 need to plug the power cable into correct power input required if need to use DMX console to control the Par lights please connect the DMX console with DMX cables If many sets of High Power LED Par 64 lights are used together each High Power LED Par 64 need to plug the power cable into correct power input required please connect these High Power LED Par 64 lights with the DMX cable If need to use DMX console to control them please connect one of the High Power LED Par 64 light to the DMX console with DMX cable and do the settings as DMX mode required as this user manual instructed 2 wm Set Up Power Supply Before plugging your unit in be sure the source voltage in your area matches the required voltage for your High Power LED Par 64 Light The High Power LED Par 64 is AC 240V use Because line volta
4. er units to be Slave by set their Addr as any DMX address Work with DMX Please connect all the units with DMX Signal cables choose one unit as Master and connect it to the DMX controller and choose the mode of Addr set its Addr to be any DMX address and set all other Slave units by set their Addr to be the same DMX address as Master unit DMX Mode Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs This function also allows you to use your units as spot lights This function will allow you to control each individual unit s traits with a standard DMX 512 controller 2 The High Power LED Par 64 light uses 6 DMX channels to operate Please refer to 6CH DMX values and functions chart as below 3 To run your unit in DMX mode plug in the unit via the XLR connections to any standard DMX controller Set your desired DMX address following the setup specifications that come with your DMX controller Note When in Master Slave Synchronization Mode only one unit in a series chain can be set as the master 5 6CH DMX Values and Functions Channel Vale Function S lt Cid 0 9 Nofuncion O S y Of No function 2 STROBE 11 255 STROBE 0 100 No function 2 255 RED brightness 0 100 No function 2 255 Green brightness 0 100 5 No function PEHE 2 255 Blue brightness 0 100 91 110 R B on 111 130 R G on 131 255 R G B on 6 RGB MIXING
5. ge may vary from venue to venue you should be sure your unit voltage matches the wall outlet voltage before attempting to operate you unit DMX Linking To ensure proper DMX data transmission when using several DMX units try to use the shortest cable path possible The order in which units are connected in a DMX line does not influence the DMX addressing For example a unit assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a unit is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Operating Instructions Operating Modes You can use the LED Par 64 light in 6 ways please select the mode through pressing the following buttons ENTER UP DOWN ESC SOUN Sound Active mode this unit will react to sound when under this mode please press UP and DOWN button until it shows the SOUN please press ENTER to choose 2 type of sound mode SOU1 and SOU2 SOUT is function for sound active for white strobe RGB mixed press ENTER if you choose this mode and there are 13 degrees sound sensitivity for your choices 100 S112 please note S100 is for no Sound Active SOU2 is function for sound active for color change press ENTER if you choose this mode and there are13 degrees sound sensitivity for your choices S200 S212 please note S200 is for no Sound Active FLAS Str
6. obe Mode press ENTER to choose this function this unit will automatically strobe under this mode press ENTER to choose RGB color strobe please select Frgb and F001 F012 is for strobe speed choices then press ENTER to choose RGB each color brightness Fr00 Fr12 is for from 0 100 RED BRIGHTNESS choice Fg00 Fg12 is for from 0 100 GREEN BRIGHTNESS choice Fb00 Fb12 is for from 0 100 BLUE BRIGHTNESS choice FLO Color Fade Flowing Mode press ENTER to choose this function this unit will automatically fade to choose fade speed please select from F001 F012 CHAS Color chase Mode press ENTER to choose this function this unit will automatically jump seven colors in sequence of RED GREEN BLUE ORANGE CYAN PURPLE WHITE to choose color jump speed please select from C001 C012 LrGb Manual Mode press ENTER to choose this function this is for operator to adjust the R G B brightness manually Lr00 Lr12 is for from 0 100 RED BRIGHTNESS choice LG00 LG12 is for from 0 100 GREEN BRIGHTNESS choice Lb00 Lb12 is for from 0 100 BLUE BRIGHTNESS choice 2 4 Addr DMX Mode press ENTER to choose this function this is for unit to work under DMX mode the small round dots near A flashes stands for there is DMX signal input if no flashes means no DMX signal input Master slave settings Work Without DMX Please connect all the units with DMX Signal cables choose one unit as Master and run the above modes except Addr set all oth
7. out prior notice 4 4