Home
eXpunhbox voidb@x penalty @M 5000
Contents
1. about 25 meters Penetration Depth Operating Mode Discrimination about 25 meters Penetration Depth Operating Mode Metal Detector about 2 meters Penetration Depth Operating Mode Live Scan Le about 25 meters Table 1 Technical Specifications Control Unit depends on object size and ground conditions OKM Ortungstechnik GmbH www okm gmbh de 3 Technical Specifications 11 3 2 Data Transmission Technology oooooooorrr mH rh ah USB Maximal Data Transmission Rate RII 19200 Baud Table 2 Technical Specifications Data Transmission 3 3 Computer Minimum Requirements The computer is not part of the scope of delivery The indicated values should help you for a correct selection of a suitable computer for analysis of your measured results PrOCO A minimum 1500 MHz CORON ML A minimum 4x Com Porm Data Ten mir 01 enteres USB Free Memory nr minimum 20 MB Working Memory IRAM essen minimum 128 MB Gr Ward gaa minimum 64 MB OpenGL compatible Operating System sssseeseee rnrn nnen Windows 98SE Me 2000 XP Table 3 Technical Specifications Computer Minimum Requirements OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 12 4 Scope of Delivery In the following section you can find all standard equipment The scope of delivery can be dif ferent in some circumstances because of some optional
2. 43 OKM Ortungstechnik GmbH www okm gmbh de 1 Preface 7 1 Preface Dear customer in the first instance we want to thank you that you made your decision on a product of OKM Ortungstechnik GmbH With the eXp 5000 you purchased a product which is based on a electromagnetic pulse method which can be used to locate anomalies in the target area Thus the device is able to detect natural features such as formations of strata cavities groundwater level as well as sepulchers or buried objects such as pipes tanks boxes or suchlike The eXp 5000 is able to locate to document and to analyse buried objects with different struc tures without making necessary any excavation Particularly in areas next to the surface there are many advantages to geoelectric seismic and magnetic procedures and it is further more a usefull complement to these methods The eXp 5000 has a facile and flexible handling and provides fast and easy reproducible results With our team of specialists we guarantee that our products are under recurrent control Our specialists try to implement new developments in terms of further quality improvements for you Of course by selling our products we cannot guarantee that you really make a find during your research The recognition of hidden objects and structures depends on a hugh number of factors like you know Determining factors are the dielectricity constant of the ground the grade of mineralisation and the dimen
3. 2 rn Installation of Device Driver Step5 2 rs Installation of Device Driver Step 6 l llt Lon NN gk eRe ee eoe eee eae eee eee ee Eee s EE View bea eee 394 asa RENE 353 593 5433 A340 19 Row m ROS 9 4 5x 89 5 x Video Eyeglasses eee eee eee hes Magnetometer Main Menu Representation of Values OIM e anio y aa a AAA A A Ground Sean SUDOR A E ew Ground Scan Parameter l l el ll rs Lap OF Parallel coo u sa un m bom ook woe kee Hee oe eS SOD Sllatt ree SOAM Ine rss eGR RAE RRR Eh X a Graphical Representation of a Measurement in Operating Mode Ground Scan Select Stored Measurement 2 2 2 2 2 2 2 2 2 5 cubren Browse SCANS co claras oe X omo eee RO ADOS Sov m Ro eS Gro NaO vo wo A9 ue X Fue ad Metal Deledlor doen 2 x aa GR ok Re ko xo o XOU OTEK Ow oy pee a ook o DOR deo R ORO X036 9 deo A Curve Shape of ron lt lt sa xo om mob arar X ob ee em Curve Shape of Precious Metals a a Curve Shape of Cavities o xo oo m Be ee ew EERE ESE HEED EES Live Scan Orientation of the LiveStream Sensor Live Scan Main Menu Representation of Measured Values DOES uos BG wee ee Ae 5499 X52 94 3 x x v 2 EI eo siones esas e AE Control Elements of the Detector rn nen Control Elements of the VLF Sender En nen Connection of Sender Antenna ew 99 oo 99 9 o9 ah ea v Xo e Connection
4. Assembly Installation of Device Driver Control Elements OKM Ortungstechnik GmbH www okm gmbh de J OO 00 00 00 00 10 10 11 11 12 14 17 20 20 21 22 23 24 25 26 26 29 32 33 39 36 37 38 38 39 40 41 41 User s manual eXp 5000 11 Analysis and Evaluation of Measurements 11 1 Metal or Mineralisation gt x wx bo 3 wo xo 9o Rok wow xw oy Rok ee 11 2 General Procedure e oom xus OER Ow e ose eec Een 11 3 Regulation of the Number of Impulses len 12 Danger of Explosion during Excavation 13 Error Messages 14 Maintenance and Services OKM Ortungstechnik GmbH www okm gmbh de 45 45 4T 48 50 5l 54 List of Figures List of Figures O CON MO OK WN e mom EI e eB oum qe ea OA A A A A A A A A A NN NN NN NN DN DN DD DN DN N e e PR BP RP E A Clr CON ER O OO JI C5 Ol 4 CO DF Cees O oO e WN EP O VO 0 S amp S Ct nn cope OL Deliyery s s e ss ead wa AAA AAA Assembly and Connection of Probe aoaaa aaa a a a a Connection of External Power Supply aooaa a a rn Connection of Video Eyeglasses nn Connection of the USB Data Cable Connection of the Detector Unit rn ren Installation of Device Driver Step l es Installation of Device Driver Step 2 ee Installation of Device Driver Step 3 2 rs Installation of Device Driver Step 4
5. The marking will change so that only the current value is highlighted in red color Now you can change the value of the selected parameter by using the keys Previous Operating Mode and Next Operating Mode To finish this process you have to press again the key Activate Operating Mode Go to your start position and adjust all necessary parameters to your needs Then you have to select option Start Scanning to start the measurement The message from figure 22 will appear and ask you if you want to start your first measure line now Ground Scan f Do you want to scan f the first line now vi wr Figure 22 Start first scan line While using the keys Previous Operating Mode and Next Operating Mode select option Yes if you want to start the measurement Confirm your selection by pressing the key Activate Operating Mode While the device is now sending out the impulses regularly you have to walk continiously your first measured line As soon as your first scan line is finished a new message will appear where you have to select Yes if you want to scan another measured line Repeat this procedure until you scanned your complete area Step by step a graphical represen tation similiar to figure 23 will built up The graphic should represent green color values in majority which represent normal ground In this green area red and blue objects can be placed Metallic objects are normally represented in red and cavities water reser
6. accessories which should not be included in the basic equipment Control Unit 1 Video Eyeglasses with Integrated Headphones 1 Linkage of Probe with GPS Receiver Extern al Power Supply 1 Charger for External Power Supply 1 Cable for External Power Supply 1 Horizontal Probe 50cm 1 Manual 1 Carrying Case 1 3D Software Visualizer 3D 1 USB Connection Cable 1 Horizontal Probe 25cm optional 1 Horizontal Probe 75cm optional 1 Horizontal Probe 100cm optional 1 Antenna for Tunnel Detection optional 1 Super Sensor optional 1 Antenna for Metal Discrimination Detector optional 1 LiveStream Sensor optional 4 VLF Sender optional Table 4 Scope of Delivery Beware that pictures in this manual could be different to delivered parts OKM Ortungstechnik GmbH www okm gmbh de Control Unit Horizontal and with Linkage for Probe Vertical Probes Detector Coil Detector Unit USB Connection Cable Charger for External Power Supply External Power Supply Including Cable Video Eyeglasses Figure 1 Scope of Delivery OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 14 5 Assembly In this section it is explained how to assemble the device and how to prepare a measurement Figure 2 Assembly and Connection of Probe Figure 2 shows how to assemble the standard horizontal probe to the linkage Therefore just put the probe into the appropriate attachm
7. cable 2d Onen 4 Gemeinsame Dokumente ffnen Dateityp Eigene Dateien Abbrechen Metzwerkumgebung Pr Figure 11 Installation of Device Driver Step 5 After successful installation of the driver a message like in figure 12 will appear on your computer screen Now the drivers of your device are installed and you can transfer data to your PC ij Neue Hardware gefunden x Die neue Hardware wurde installiert und kann jetzt verwendet werden mr Figure 12 Installation of Device Driver Step 6 OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 20 7 Control Elements In this section you will learn more about the fundamental use of all control elements for this measuring instrument All connections inputs and outputs are explained in detail 7 1 Control Unit The control unit is the calculation center of the device Via the control unit the programs can be selected all measured values can be recorded and stored Slide In for Detector GPS Receiver Control Keys Retaining Handle Linkage for Probe Figure 13 Control Unit The Linkage for Probe is used to attach the probe to the linkage The GPS Receiver is used for navigation with GPS The receiver should be orientated towards the sky to get the best data transmission from the satellites With the Slide In for Detector you can fix the detector unit The Control Keys are used to navigate the control unit OKM
8. discriminator without holding the probe directly above the ground e You are holding the probe during your confirmation of the operating mode with integrated discriminator to high and then minimize the distance to the ground e You are turning the regulator for discrimination during soil reconciliation Only if you are doing a correct soil reconciliation the functionality of discrimination can be guaranteed OKM Ortungstechnik GmbH www okm gmbh de 11 Analysis and Evaluation of Measurements 45 11 Analysis and Evaluation of Measurements Before measurement you have to know what kind of objects or cavities you are looking for and if the area you choose is suitable for this Measurement without a plan will not give you the results you would like For this reason please consider the following indications e What are you looking for graves tunnels buried objects This question has its effects on your concrete manner to measure an area If you are looking for big objects you can enlarge your distance between the measure points impulses for small objects use small distances see section 11 3 on page 48 e Inform yourself about the area you select for measurement Is it usefull to search at this place Are there historical indications which confirm your speculations What type of soil is on this area Are there good conditions for data recording e Your first measurement in a unknown area has to be large enough to
9. eXp 5000 26 8 2 Ground Scan This operating mode allows you to do a measurement with graphical representation whereby all measured values will be stored in the internal memory of the device Also you have the possibility to recall and see previous stored graphics or to use the GPS system for navigation to these measurements This mode can be used with all antennas except the DDV system and livestream sensor Main Menu Ground Scan Figure 18 Ground Scan In the first submenu which is represented in figure 19 you can choose between the following alternatives e New Scan Set up and record a new graphic e Browse Scans See or delete stored graphics If the measurement has been made while using GPS you can navigate to the measured area e Back To Main Menu Finish Ground Scan and go back to the main menu 8 2 1 New Scan After activating this operating mode you have the possibility to adjust certain settings There are different parameters which influence the measurement In figure 20 you can see the corre sponding submenu You can modify the following parameters the underlined values correspond to the setting made by the factory e Impulse Mode Automatic Manual If you are working in mode Manual the measured values will only be recorded when using the Emitter of Impulses If you select mode Automatic the measured values will be recorded and represented continiously OKM Ortungstechnik GmbH www okm gm
10. stored data without having transferred them to your computer OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 52 Figure 51 Internal Hardware Error If message 51 appears the device cannot control the operating voltage This also means it can not warn you in case of a low status of the battery Also the automatic shutdown of the device may be affected It is adviced to let the device check from the manufacturer to avoid further damages Ask your dealer for further help Figure 52 The external power supply has to be charged Message 52 appears if the battery is low because of a long operating time with the device and not enough voltage is available You should power off the device and charge the external power supply as soon as possible If you continue operating with the device it could be possible that data can get lost Figure 53 Shutting down the system Because there is a PC module integrated in the device you have to shutdown it like a normal OKM Ortungstechnik GmbH www okm gmbh de 13 Error Messages 53 computer Therefore you have to use option Exit from the main menu The following message like in figure 53 remind you to wait until the device powered off by itself Figure 54 Shutting down the system is not possible If the device itself is not able to power off a message like in figure 54 is shown In this case you simply power off your external power supply Figure 55 Pro
11. Future Series eXp 5000 User s manual User s manual eXp 5000 2 Any information contained in these operating instructions may be changed without prior notice OKM does not make any warranty for this document This also applies without limitation to implied assurances of merchantability and fitness for a specific purpose OKM does not assume any responsability for errors in this manual or for any incidental or consequential damage or loss associated with the delivery exploitation or usage of this material This documentation is available as presented and without any kind of warranty In no circumstances OKM takes responsibility for lost profits usage or data losts interruption of business activities or all kind of other indirectly damages which developed because of errors in this documentation This instruction manual and all other stored media which are delivered with this package should only be used for this product Program copies are allowed only for security and savety purposes The resale of these programs in original or changed form is absolutely forbitten This manual may not be copied duplicated or translated into another language neither in part nor completely over the copyright matters without the prior written consent of OKM Copyright C 2002 2006 OKM Ortungstechnik GmbH All rights reserved OKM Ortungstechnik GmbH www okm gmbh de Contents Contents 1 Preface 2 Important Notes RL Sol Ui s
12. M Ortungstechnik GmbH www okm gmbh de 8 Operating Modes 25 8 1 Magnetometer You select operating mode Magnetometer in the main menu to determine the subsoil taking the earth magnetic field into account Also you can recognize through the graphical representation of a oscilloscope like picture on the monitor if you are placed above an metallic object Main Menu Magnetometer Figure 17 Magnetometer Main Menu Representation of Values This mode can be used with all antennas except the DDV system and livestream sensor As soon as you confirm the operating mode Magnetometer the integrated magnetometer will be adjusted to the current basic ground value of the place where it is situated in this moment During the initialization process the message Ground Balance Please Wait appears on the display Only if this message disappears you can start your research If you power on the device above neutral ground all metals will be shown with a deflection to the top in your monitor If the device is situated above a metal while activating the magnetometer all equivalent metal parts will not be recognized By a new press on the button Activate Operating Mode you can initiate a manual soil reconciliation Therefore you have to start on a place with neutral ground With buttons Previous Operating Mode Or Next Operating Mode you are leaving the magnetometer mode and turn back to the main menu OKM Ortungstechnik GmbH www okm gmbh de User s manual
13. Next Operating Mode until it is highlighted in red color Now press the key Activate Operating Mode The marking will change so that only the current value is highlighted in red color Now you can change the value of the selected parameter by using the keys Previous Operating Mode and Next Operating Mode To finish this process you have to press again the key Activate Operating Mode OKM Ortungstechnik GmbH www okm gmbh de 8 Operating Modes 37 8 7 Exit You have to select option Exit to finish the operation with this device As soon as you con firmed this selection the integrated pc module will shut down and the device will power off itself Main Menu nd Figure 35 Exit Please wait until the device has powered off itself After the device is switched off you can power off the external power supply OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 38 9 Additional Optional Equipments Here you can find important information about all available optional equipments for this device 9 1 Disc Detector Visualization System DDV With the DDV a powerful metal detector is on your disposal which not only supports your underground research with a visual representation but also offers you various filter possibilities Sensibility Regulator Operating Lamp Discriminator D Connector Retaining Handle Coil Figure 36 Control Elements of the Detector To use the detector just plug in the connector D i
14. Ortungstechnik GmbH www okm gmbh de 7 Control Elements 21 7 1 1 Front View Figure 16 shows the front side of the control unit Slide In for Detector ELE eee Emitter of Impulses Power On ane Off Button Previous Next Activate Operating Mode Operating Mode Operating Mode Figure 14 Front View The Slide In for Detector is used to attach the detector unit The suitable counterpart is fixed on the detector unit where the unit can slide in With the Emitter of Impulses Power On and Off Button you can power on and off the device Therefore you have to move the emitter towards yourself until it snaps in the front position Before op erating your measuring instrument you have to connect the delivered power supply and power on During a measurent in operating mode Ground Scan you can release manually impulses for recording measured values Therefore you have to move the emitter backwards away from yourself It will turn back automatically if you let it go With the keys and you can select the different operating modes To confirm your selection you have to press the key l OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 22 7 1 2 Back View Figure 15 shows the back side of the control unit with all their connections Connection Connection of Probe of Video Eyeglasses Sound BEAT o5 ls MEAM USB Connection Connection of Cable to Connection External Power Supply GPS Receiver of Video Eyeglass
15. ar made use of diabolical inventions such as rocker fuses acid fuses and ball fuses Those components have been rusting away in the course of time and the slightest movement may cause parts of them to break and be triggered Even seemingly harmless objects such as cartridges or large ammunition are anything but that Explosives may have become crystalline over time that is sugar like crystals have formed Moving such an object may cause those crystals to produce friction leading to an explosion If you come across such relics mark the place and do not fail to report the find to the police Such objects always pose a danger to the life of hikers walkers farmers or children OKM Ortungstechnik GmbH www okm gmbh de 13 Error Messages 51 13 Error Messages In this section you can find possible error messages which can appear during the work with the device Figure 49 Only a small amount of memory available Because every scan in the operating mode Ground Scan will be stored in the internal memory of course the memory place will decrease over time As soon as the free memory cell is less than 20 the following message like in figure 49 will appear Figure 50 No free memory available If there is no more free memory available you will see a message like in figure 50 You can create more memory space if you transfer all stored data with optional software to your computer or if you select option Empty Memory to delete all
16. are used The Regulator of Capacity is prosecuted generally between 50 and 100 Figure 40 Placement of the VLF sender on a site Place the four VLF sender in a square or rectangle and power on all sender Now you can execute a normal measurement in operating mode Ground Scan see figure 40 By using the VLF sender in particular all metallic objects will be enforced more than a measurement without sender Important is the correct adjustment of the parameters of frequency and capacity An exact specification is not possible because it is strongly depending on the particular ground circumstances 9 2 3 Safety Guidelines It is absolutely necessary to beware the following safety guidelines to guarantee a secure work with the VLF sender e Do not hold any receiver like metal detectors probes or others directly over the sender antenna during the operation of the VLF sender The enforced field of the antenna can destroy their electronics e Keep a distance of at least 50cm between antenna and VLF sender Avoid close contact to the sender antenna during operation OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 42 If a change of electrical fuse should be necessary only fuses which are structurally identical may be used which value agrees with those on the equipment Power off the device before loading the internal batteries For charging use only the provided battery charger Power off the device if it is
17. ass above an iron object Typi cally is the high deflection to the top followed by the same deflection down OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 34 Figure 30 Curve Shape of Precious Metals Figure 30 shows which principle curve shape is created if you pass above a precious metal Typ ically is the small additional deflection with the difference that there is no deflection down Figure 31 Curve Shape of Cavities Figure 31 shows the principle curve shape when passing over a cavity Typically is the high deflection down But there is no equivalent deflection in the opposite direction OKM Ortungstechnik GmbH www okm gmbh de 8 Operating Modes 35 8 5 Live Scan To work in the operating mode Live Scan you have to connect the LiveStream Sensor to your device This probe is marked with a white arrow which is fixed on the upper side of the probe During a measurement this white arrow should always be directed to the left side Also you should take care that the arrow which is situated on the strait side of the probe is always directed to the ground Be sure that the probe is correctly aligned before activating this operating mode Figure 32 Live Scan Orientation of the LiveStream Sensor In this operating mode you do not have to keep a defined scan direction You can walk for wards or backwards over your measured area On the screen you will see immediately what is currently situated right under th
18. bbrechen Figure 10 Installation of Device Driver Step 4 Another window will open represented in figure 11 where you have to select the driver file Therefore click on Data carrier Immediately another window appears where you click on the button Search Then select the file OKM LE INF which you can find in the directory drivers usb_cable of your software CD Afterwards you have to click on Open OK and Next to start the installation of the files OKM Ortungstechnik GmbH www okm gmbh de 6 Installation of Device Driver 19 Assistent f r das Suchen neuer Hardware Wahlen Sie den fur diese Hardware zu installierenden laeratetreiber e ae S Wahlen Sie den Hersteller und das Modell der Hardwarekomponente und klicken Sie auf fe weiter Klicken Sie auf Datentr ger wenn Sie uber einen Datentr ger verf gen der den erforderlichen Treiber enthalt Kompatible Hardware anzeigen Modell Installation von Datentr ger xj Legen Sie den Installationsdatentr ger des Herstellers DK aL ein und stellen Sie sicher dass weiter unten das richtige share soccer ahli iE Abbrech 21x iab Datentr gern Suchen in 2 usb cable 10O rri n N Zuletzt verwendete Dokumente 8 ok LE Desktop I Eigene Dateien T gt Abbrechen E Arbeitsplatz s 3 Diskette A Durchsuchen amp 3 SYSTEM E a DATEN D a RECOVER E D vD Laufwerk F e CD Aw Laufmerk 3 LO drivers Dateiname _ ust
19. bh de 8 Operating Modes 27 Ground Scan Browse Scans Back To Main Menu Figure 19 Ground Scan Submenu Ground Scan Impulses 10 Scan Mode Parallel GPS Off Start Scanning Back To Ground Scan Menu Li Os ox Figure 20 Ground Scan Parameter e Impulses 10 20 100 Number of measured values per search line How to select the right number of impulses you can read in section 11 3 on page 48 e Scan Mode Parallel Zig Zag Scan Mode defines the method of scanning an area In mode Parallel measurement starts always from the starting line whereas in mode Zig Zag measurement starts at the end of the line which was scanned before like represented in figure 21 In the last scanning method you have to take care not to change the orien tation of the antenna which means if the white arrow on the side of the probe shows to north direction for example it has to show to north direction in every measured line e GPS Off On If GPS is activated On the GPS coordinates longitude and latitude will be stored automatically according to every measured value This data is important if you want to use the GPS navigation Select the parameter which you want to change with the keys Previous Operating Mode and Next OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 28 Figure 21 Zig Zag or Parallel Operating Mode until it is highlighted in red color Now press the key Activate Operating Mode
20. ct or not Temperature other radio transmission sun energy mineralisation of the ground loam salt water etc can influence negatively the measure results Before you start to dig take your time to do some control scans Repeat exactly the same scan about 3 5 times to be sure about your results Only if all these graphics have almost the same values you can be sure about your results Figure 44 is a graphical representation of a measured area The blue rectangle marks a possible object in the ground To be absolutely sure that there is an object in the ground you have to do a control scan Measure exactly the same area same starting point and the same number of impulses and lines Take also the same distance between the measure points Figure 45 and 46 shows two possible measurements OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 48 Fi Fi surement of an area Figure 45 Control scan Variant A It is easy to recognize that the control scan in figure 45 is totally different from the first measure ment in figure 44 This means only a mineralisation of the ground not a concrete metalic object Even if the control scan in figure 46 is not exactly the same to the first one you can see that the blue marked parts show nearly the same values This is a reference for the existence of an object Figure 46 Control scan Variant B Before you can determine the depth of the detected object you have t
21. e probe The graphical representation is similar to operating mode Ground Scan Main Menu Live Scan Figure 33 Live Scan Main Menu Representation of Measured Values All measured data will flow over the screen Also when you are not moving the measured values were updated constantly If you are situated right over a target it will be visible on the screen also if you are not moving The measured values in operating mode Live Scan cannot be stored OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 36 8 6 Settings In this operating mode you have the possibility to set the date and time The correct adjust ment of date and time are very important because both settings are stored together with the graphical measurement in menu Ground Scan This allows you to identify each measurement according to date and time Main Menu Settings System Date 18 04 2005 Time Format 24 hours System Time 10 40 Back To Main Menu Figure 34 Settings You can select between the following possibilities e Date Format Setting of date format day month year day month year day month year e System Date Setting of date e Time Format Setting of time format 24 Hours 12 Hours 4 am pm e System Time Setting og time Preset is Central European Time CET e Back To Main Menu Leave Settings and go back to Main Menu Select the parameter which you want to change with the keys Previous Operating Mode and
22. e you are using 2 1 General Notes Being an electronic device eXp 5000 has to be treated with the caution and care necessary when such devices are used Any failure to observe the safety precautions given or any use for purposes other than the ones it is conceived for may result in a damage or destruction of the processing unit and connected components The device will get destroyed if it is opened improperly 2 2 Possible Health Hazards If used properly the device normally does not pose any health hazards According to current scientific knowledge the high frequency signals are not harmful to the human body on account of their low power 2 9 Surrounding Area Having been transferred from a cold to a warmer place the device should not be operated im mediately afterwards Any condensation which may have formed might cause the device to get destroyed Avoid strong magnetic fields which may occur in places such as near machines or loudspeakers and avoid using a detector within a radius of 50 meters Metallic objects on the ground such as cans doses catches nails screw or others can influence negatively your measurement and have to be removed Also you have to remove keys telephones chains and rings and all other magnetic and metallic objects from yourself OKM Ortungstechnik GmbH www okm gmbh de 2 Important Notes 9 2 4 Voltage The power supply should not be outside the indicated range of values Use only charge
23. e5 concern the use in normal type of soil In extreme conditions mineralisation salt deposits they can variate from this normal value OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 44 e the detector does not react there is probably golden material in the ground but also bronze is possible Please consider that you always should do the soil reconciliation which is explained in this following section 10 2 Soil Reconciliation A correct soil reconcilation is absolutely necessary that the adjusted discrimination can work properly If the soil reconciliation is not done correctly the operation of the device and the integrated discriminator cannot work properly In the following section you can find a list of all necessary working procedures to do a correct soil reconciliation 1 Power on the device and wait until the acoustic signal disappears 2 Adjust the discriminator on the material you like see previous section 3 Put the device with coil probe about 5cm above the ground 4 Select the operating mode you like and confirm If you hear an acoustic signal from the metal detector after these indications then the soil rec oncilation is not finished correctly Repeat these steps until there is no acoustic signal from the metal detector The following causes can prevent a correct soil reconciliation e You are staying above a metalic object e You confirm the operating mode with integrated
24. ent of the linkage Then connect the probe cable with the control unit Do it without any unnecessary application of force The vertical probes can be used without linkage You can simply hold it in your hand perpendicularly to the soil Figure 3 Connection of External Power Supply Figure 3 shows how to connect the external power supply to the control unit The cable is placed inside a storage case on the back side of the battery and is wired to this power supply While connecting the external power supply take care to connect at first the cable with the control unit The external power supply has to be powered on afterwards OKM Ortungstechnik GmbH www okm gmbh de 5 Assembly 15 Figure 4 Connection of Video Eyeglasses Figure 4 represents the connection of the video eyeglasses Plug in both connectors of the video eyewear into the correct connection of the control unit Figure 5 Connection of the USB Data Cable Figure 5 shows how to plug in the USB connection cable to the computer Further information about the use and installation of the USB driver you can find in section 6 on page 17 OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 16 Figure 6 Connection of the Detector Unit Figure 6 shows how to assemble the detector unit on the control unit You can plug in the unit on the according linkage of the top side of the control unit without any application of force OKM Ortungstechnik GmbH www ok
25. es Image Figure 15 Back View The Connection of Power Supply is used to connect the device with the delivered battery Here the external power supply Power Tank has to be connected The Connection of Probe the cable of the probe or the cable of the detector unit has to be plugged in On the Connection of Video Eyeglasses you have to plug in the cable of the delivered video eyeglasses The USB Connection is used to connect the device to a computer via usb data cable OKM Ortungstechnik GmbH www okm gmbh de 7 Control Elements 23 7 2 Video Eyeglasses The video eyeglasses are used as the display for this device All menus and graphical repre sentations are represented via these video eyeglasses Connect the Connector Socket of the video eyeglasses to the Connection of video eyeglasses on the back side of the control unit Headphones Left Headphones Right Connection Cable Regulator of Sharpness for Left Eye Regulator of Sharpness for Right Eye Power On and Off Button Video Switch Over Regulator of Regulator of Lightness Volume Figure 16 Video Eyeglasses The Connection Cable is used to connect the control unit with the video eyewear The Power On and Off Button is used to switch on and off the video eyeglasses Just push the button shortly With the Regulator of Sharpness you can adjust the sharpness if the image individually With the Regulator of Lightness the lightness of
26. es the eee he HEBER KREGER GS Tl Troni VIEW eun gem oe Pee eee ee wR ee pos Dl denk VIEW sesos iras PRE koX OES 33 T 2 Video Eyeglasses 0 Operating Modes Owl Denen sra A GE Dee SPR Sa SSC DN Ge hae ee RR XE Rue E eA 9 ux kd E SHG Ou New DOC eoe ow dab daw m vox x RO Y 44 ox HHS 5 2 2 Browse Dale umo o ap RA o UR Rm dei oh moe e Eos eo Metal Detector ss ege yo kw Row RkOX ROReOROX Rok OE Eon os DOLI Det oso x ee OROxOS RR ROW X omo e go x mo INCA ae ee ee eee 289 89 Ree eee CA e nou oa Ge eh eo eR oe OER HORE GS OG ERI JI ab tubo ae eRe aa Additional Optional Equipments 9 1 Disc Detector Visualization System DDV 9 2 Very Low Frequency Sender VLF 72 1 ASOMO a6 ne itip errire pii Sew 9 2 2 Usage of the VLF Sender 9 2 3 Safety Guidelines ee eee 10 Discrimination 10 1 Adjust the Discriminator 00000 10 2 Soll Reconciliation s ss eses nu 00 0 sn ODER ww nn 2A General Notes on wc Xo ceo o RO oh khOX X ES 2 2 Possible Health Hazards 23 DQULIDONHPS AXIS doce dea wa gee bide kad oo Pow pe VO cee woscs sw ee Oe ot ee we ee ee 20 Dora 309 4 BRAG REE AAA Technical Specifications El Smet sas oros ox Data Transmission gt e se s sss radaro roa ka dd p we oradi 3 3 Computer Minimum Requirements Scope of Delivery
27. get representative values f ex 20 impulses 20 search lines e What is the form of the object you search If you are looking for an angular metal box the identified object in your graphic should have a form according to this e To get exact values concerning the depth measurement the object has to be in the centre of the graphic which means it has to be framed by normal reference values normal ground If the object is on the side of the graphic and not totally visible a correct depth measurement is not possible e There should not be more than one object in a graphic This will influence the exactness of depth measurement e You should do at least two control scans to get sure about your results So you also can recognize and isolate mineralized ground see section 11 1 on page 45 11 1 Metal or Mineralisation At the beginning it is not always easy to make a difference between real objects and mineralized ground In principle metals are represented in red color but mineralized accumulations can also include red signals Here some advice how you can differentiate between a real object and a mineralisation e Form If the object represented in your graphic has a special form f ex rectangle circle you can conclude of a possible real found e Color If there are many yellow and orange color values around the object it will be probably a mineralisation e Depth With a small depth of about 0 10m or 0 40
28. gmbh de User s manual eXp 5000 32 8 3 Metal Detector To use this operating mode you have to connect the optional DDV system at first The detector is specialized to find small objects e g coins which are located near to the surface Main Menu Metal Detector Figure 27 Metal Detector Also with the detector you have the possibility to determine the material of possible objects So for example you can find out if an object consists of gold silver or iron Further information about the correct usage of the detector and the principle of discrimination you can find in section 9 1 on page 38 and in section 10 on page 43 of this users manual OKM Ortungstechnik GmbH www okm gmbh de 8 Operating Modes 33 8 4 Discrimination This operating mode is used to identify metals and cavities Therefore it is necessary to connect the optional available super sensor or the antenna for tunnel detection There is no given manner fixed or a scan direction You can walk as you want to determine the soil This operating mode is most effective if you already detected possible objects and now want to know more details about them Main Menu Discrimination Figure 28 Discrimination During the measurement you will get a live picture on the screen of your device The different curves give conclusion to the characteristics of possible objects Figure 29 Curve Shape of Iron Figure 29 shows which principle curve shape is created if you p
29. gress of Data Transmission If you transfer data from the device to your computer you can see how many of the files are already transferred Figure 55 shows the progress of data transmission OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 54 14 Maintenance and Services In this section you will learn how to maintain your measuring instrument with all included ac cessories to keep it in good condition a long time and to get good measuring results The following list indicates what you absolutely should avoid e penetrating water e strong dirt and dust deposits e hard impacts e strong magnetic fields e high and long lasting heat effect If you want to clean your device please use a dry rag of soft material To avoid any damage you should transport the device and accessories always in the appropriate carrying cases Beware that all batteries and accumulators are always charged fully while operating with your system You should only load the batteries when they are completely discharged no matter if you are working with the external power supply or with the internal accumulators In this way a long durability of the used batteries is guaranteed To load the external and internal batteries you have to use only chargers which are part of our scope of delivery OKM Ortungstechnik GmbH www okm gmbh de Index Activate Operating Mode 25 28 29 36 scan direction 35 Slide In for Detector 20 21 Coil pr
30. just the sending frequency The Regulator of Capacity the sending capacity can be adjusted In the Connection of Antenna the delivered antenna has to be connected OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 40 9 2 1 Assembly This section describes how to assemble the sender and prepare for a measurement Figure 38 Connection of Sender Antenna In figure 38 you can see how to connect the sender antenna The antenna is fixed up with the velcro fastener on the outside of the VLF sender Remove it and put in on the ground in a distance of about 50cm from the sender Figure 39 Connection of the Charger If the batteries are empty you have to reload them Figure 39 represents how to connect the charger OKM Ortungstechnik GmbH www okm gmbh de 9 Additional Optional Equipments 41 9 2 2 Usage of the VLF Sender After you have attached the antenna and loaded the batteries completely you can operate the VLF sender Beware that the Regulator of Capacity LEVEL is switched on 0 before power on the sender and the antenna is put on the ground in a distance of about 50cm from the sender After powered on the device both Operating lamps has to shine green otherwise you should reload the batteries again Now adjust the desired frequency and capacity before scanning your area With the Regulator of Frequency you can select the desired sender frequency Normally frequencies of less than 40 kHz
31. m gmbh de 6 Installation of Device Driver 17 6 Installation of Device Driver Before you can transfer data from the device to your computer you have to install the USB driver Therefore you have to connect the active computer and the control unit via the USB connection cable When you switch on the power supply a message like in figure 7 will appear on your computer screen J Neue Hardware gefunden x exp 3000 Figure 7 Installation of Device Driver Step 1 If you prosecute Windows XP with Service Pack 2 you will be asked in dialog from figure 8 if Windows Update has to search for drivers up to date Mark entry No not this time and click on Next Assistent f r das Suchen neuer Hardware Willkommen Es wird nach aktueller und aktualisierter Software auf dem Computer auf der Hardwareinstallations CD oder auf der Windows Update ebsite mit Ihrer Erlaubnis gesucht D atenschutzrichtlinie anzeigen Soll eine Verbindung mit Windows Update hergestellt werden um nach Software zu suchen C Ja nur diese eine Mal C Ja und jedes Mal wenn ein Ger t angeschlossen wird Klicken Sie auf weiter um den Vorgang fortzusetzen 4 Lick Abbrechen Figure 8 Installation of Device Driver Step 2 In other versions of the operating system Windows this dialog window should not appear OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 18 In the following dialog window like figure 9 selec
32. m there is a high possibility that there is only a mineralisation of the ground OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 46 e Color Filter If position and form of the object are changing with the use of the color filter it is probably a mineralisation e Control Scan If position depth and form of the object stay nearly the same also in further control scans you can conclude of a real object Also if some graphics look similiar you always have to compare all indications Figure 42 shows a real object left side and a mineralized accumulation right Figure 42 Comparison of object and mineral OKM Ortungstechnik GmbH www okm gmbh de 11 Analysis and Evaluation of Measurements 47 11 2 General Procedure The main rule for scanning an area is The more exactly you scan an area the better will be your graphical evaluation You have to scan in a given manner that the software can calculate the measured values in the right way Your device has following possibilities e Zig Zag e Parallel Figure 43 shows all different ways of scanning in a scheme The measurement starts at your starting point D and ends at point Figure 43 Given manner If you have finished one scan line the next line has to be on the left side Do not change the direction of your probe The more you repeat your scanning above a possible object control scans the better you can decide afterwards if it is a real obje
33. n a large area before doing a second detailed precision measurement Especially for the search of bigger objects you can proceed like this With this manner you can measure relatively fast a large area and afterwards you can record the interesting subsection Further information about the graphical analysis you can find in the appropriate software man ual OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 50 12 Danger of Explosion during Excavation Unfortunately the last two world wars also made the ground in many places of the world a potentially explosive scrap heap A host of those lethal relics are still buried in the ground Do not start digging and hacking for an object wildly when you receive a signal of a piece of metal from your device Firstly you might indeed cause irreparable damage to a truly rare find and secondly there is a chance that the object reacts in an insulted way and strikes back Note the colour of the ground close to the surface A red or reddish color of the ground is an indicator of rust traces As regards the finds themselves you should definitely pay attention to their shape Curved or round objects should be a sign of alarm especially if buttons rings or little pegs can be identified or felt The same applies to recognizable ammunition or bullets and shells Leave that stuff where it is do not touch anything and most importantly do not take any of it home with you The killing machines of w
34. not any longer used otherwise the batteries can be damaged OKM Ortungstechnik GmbH www okm gmbh de 10 Discrimination 43 10 Discrimination In this section the regulation of the discrimination and the soil reconciliation is explained 10 1 Adjust the Discriminator The discriminator serves to filter certain materials So it is possible to erclude for example worthless iron and steel objects Or people who are hunting for treasures and gold are able to exclude other materials with the help of this discriminator Figure 41 Adjustment of discrimination In figure 41 the regulator to adjust the discrimination is represented This regulator can filter certain materials Table 5 explains the adjustment in the case of normal ground conditions Po All metalic bete Table 5 Standard adjustment of the discrimination Beware When you adjust the regulator for discrimination on gold the detector reacts besides gold also on bronze silver and aluminium To find out if there is really gold in the ground you have to follow the following instructions Switch the regulator on gold and start your soil examinations until you reach a place where the detector reacts positive 2 Now switch the discriminator on silver and examine this place again Following there will be two possibilities e the detector reacts positive the material under the ground is not gold but could be silver or aluminium The indications from tabl
35. nto the Connection for Probe of the control unit Then select the operating mode Detector in the main menu Attention As soon as you confirm this option the soil reconciliation will start Detailed infor mation you can find in section 10 on page 43 Now you have to pivot the detector coil continiously right above the ground trying to keep the same distance to the soil Adopt the rhythm of the graphical representation on the screen As soon as you pass above a metallic object a yellow colored trace will appear in your graphic and you can hear an acoustical sound through the headphones OKM Ortungstechnik GmbH www okm gmbh de 9 Additional Optional Equipments 39 9 2 Very Low Frequency Sender VLF With the VLF a sender is available which can optimize your search for metallic objects Connection of Antenna Socket of Charge Security and Operating Lamp Power On and Regulator of FrequeRegulator of Capacity Off Button Figure 37 Control Elements of the VLF Sender With the Power On and Off Button the device can be switched on and off In the Socket of Charger the charger has to be connected to reload the internal batteries The state of the batteries can be surveilled and controlled with the Operating Lamps If the batteries are charged fully the operating lamps will shine green With decreasing of the voltage the lamps will change the color themselves from yellow to orange up to red The Regulator of Frequency is used to ad
36. o scan a further image It only should cover the blue marked area All other metals and mineralized ground should be ig nored because it would disturb the measurement After this you can determine the correct depth 11 3 Regulation of the Number of Impulses There is no special rule for the number of impulses But there are different aspects which has to be considered These are for example e the length of your measured area and e the size of the objects you are searching OKM Ortungstechnik GmbH www okm gmbh de 11 Analysis and Evaluation of Measurements 49 The optimal distance between two impulses is about 20cm until 30cm The smaller the distance between two impulses is the more exactly will be the graphical representation If you are looking for small objects you have to select a small distance for big objects you can increase the distance between each impulse Figure 47 shows the effects of the distance and the number of impulses per scan line for some objects Lladd d NN Figure 47 Effect of number of impulses and their distance Figure 48 shows the difference between very few impulses left side and much more impulses on the same scan line length right side The second record right side shows much more details and also smaller objects can be seen Figure 48 Comparison of small and high number of impulses Do not hesitate to record more measurements with different numbers of impulses For example you can sca
37. obe see Probe Socket of Charger 39 Connection Cable 23 Soll reconciliation 43 44 Connection for Probe 38 Connection of Antenna 39 USB Connection 22 Connection of Power Supply 22 Connection of Probe 22 Connection of Video Eyeglasses 22 Connection of video eyeglasses 23 Connector Socket 23 Control Keys 20 Detector 44 Discrimination 43 Discriminator 43 Emitter of Impulses 26 Emitter of Impulses Power On and Off Button 21 GPS Receiver 20 30 Ground Scan 35 Headphones 23 Linkage for Probe 20 Live Scan 35 LiveStream Sensor 35 Metal Detector 44 Next Operating Mode 25 28 29 36 Operating Lamps 39 Operating lamps 41 Power On and Off Button 23 39 Previous Operating Mode 25 27 29 36 Probe 44 probe 35 Regulator of Capacity 39 41 Regulator of Frequency 39 41 Regulator of Lightness 23 Regulator of Sharpness 23 Regulator of Volume 23 55
38. of the Charger mm nenn Placement of the VLF sender on a site Adjustment of discrimination 2 2 2 2 2 2 Comparison of object and mineral ex wow oy ox onem UR E teehee Oe we Ee DIVER WAM nox em eee ewe FCR Ok x o amp omo4 X dox y 4 k A OR od SS First measurement of an area 2 CL on nen Control secan VDE sae en de a HS e X En rn OH Hs OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 6 46 AT 48 AQ 90 ol 02 99 54 I Control zen Varia D sro ewa raa a A ee cs 48 Effect of number of impulses and their distance 49 Comparison of small and high number of impulses 49 Only a small amount of memory available ol No free memory available 4 rs 51 Internal Hardware Error s 2 0 a 0 0 4 wu u u a a a R9 ee ia oko X Ron 02 The external power supply has to be charged lr 52 Shutting down the system 2l llle ss 52 Shutting down the system is not possible lll ln 53 Progress of Data Transmission o o aoao a nn 53 List of Tables JA WW N e Technical Specifications Control Unit a a 10 Technical Specifications Data Transmission e 11 Technical Specifications Computer Minimum Requirements 11 Scope of Delivery aaa 12 Standard adjustment of the discrimination
39. rs bat teries and rechargable batteries which are included in the scope of delivery Never use the 230 Volt mains supply 2 5 Data safety There can be errors in the process of data collection if e the range of the sender module is been exceeded e the power supply of the device is to low the cables you are using are to long other electronic devices sends out disturbances or atmospherics occurs lightnings OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 10 3 Technical Specifications The following technical indications are medial values During operation small variations are quite possible 3 1 Control Unit Dimensions Hx Wx DD cece cence ene 75mm x 130mm x 177mm A ge about lkg NOMAS rre 9 6 14 4 VDC 22W maximal Safety Class A A EHI pire pene NONE os IP 40 Operating Time Full Charged Battery Delivered Power Supply 25 C 06 eee eee about 3 hours Operating Temperature 6 cence ans 0C 40 C Video Eyeglasses 6 ec cc cee cece enn hh 640 x 480 Pixel Color Scie is eee ee ee ee ee ee ee ee eee eee eee eee eee ee eee eee ee 300 MHz Processor INTEL 1586 compatible o aes asadaduadquadqud quaqua E S n 64 MB RAM Darr Neem EEE ER re ee ee re ee ee SS 64 MB Feedback 4465 5260550250625284052002506245800500250525800600R000 868006888 accustic visual Penetration Depth Operating Mode Magnetometer about 2 meters Penetration Depth Operating Mode Ground Scan
40. sions of an object relating to its depth Specially in very wet soil clay and sand with high conductivity of the ground recording of the measured results can be falsified strongly With this product you purchased a device which stood the tests in regular operation like all other products of us If you are interested in where our devices have gone into action please visit our homepage For our company it is necessary that we protect our developments within the framework of exist ing legislation to a patent or trademark registration Therewith we offer you a higher warranty while using our products Please take your time consecutively read this user s manual and familiarize yourself with the utilisation and operation of this eXp 5000 OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 8 2 Important Notes Please read these operating instructions carefully and closely before using eXp 5000 and its ac cessories These instructions give information on how to use the device and point out potential sources of danger eXp 5000 and its accessories serves for documentation and analysis of detect objects deposited and changes performed in the ground The registered data of the ground structure will be transmitted to a PC for visual representation in a special software program using the components we offer Any additional notes relating to this has to be observed Please read attentively the manual according to the softwar
41. t the entry Install software from a list and click on button Next Assistent f r das Suchen neuer Hardware Mit diesem Assistenten konnen Sie Software f r die folgende Hardwarekomponente installieren OKM Quick Link 4 Falls die Hardwarekomponente mit einer CD 4 oder Diskette geliefert wurde legen Sie diese gt jetzt ein We mochten Sie vorgehen C Software automatisch installieren empfohlen Software von einer Liste oder bestimmten Quelle installieren fur fortgeschrittene Benutzer Klicken Sie auf weiter um den Vorgang fortzusetzen lt Zur ck Abbrechen Figure 9 Installation of Device Driver Step 3 In the next dialog window from figure 10 mark the entry No search select driver individually and click on Nezt Assistent f r das Suchen neuer Hardware E Wahlen Sie die Such und Installationsoptionen ES C Diese Quellen nach dem zutreffendsten Treiber durchsuchen Verwenden Sie die Kontrollk stchen um die Standardsuche zu enveltern oder einzuschr nken Lokale Pfade und wv echselmedien sind in der Standardsuche mit einbegriffen Der zutreffendste Treiber wird installiert weshselmedien durchsuchen Diskette ED Folgende Muelle ebenfalls durchsuchen ES Durchsuchen Verwenden Sie diese Option um einen Geratetreiber aus einer Liste zu w hlen Es wird nicht garantiert dass der von Ihnen gew hlte Treiber der Hardware am besten entspricht lt Zur ck A
42. the video image can be adjusted With the Regulator of Volume the volume of the Headphones can be adjusted OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 24 8 Operating Modes In this section you will learn more about the different operating modes of the device Every function is been explained in particulary in its proper subsection The right selection of an op erating mode depends primarily of your planned measurement So for example there are some special functions which have to be used for a first measurement in a unknown area to get a general overview against which others are more suitable for a detailed search and analysis with a special processing software program The device proccesses the following operating modes e Magnetometer Research of an area with the integrated magnetometer e Ground Scan Measurement with graphical evaluation whereby measured data are stored in the internal memory of the device e Metal Detector Activate optional DDV system to discriminate between metals e Discrimination Examination of detected objects regarding to their characteristics on iron contents e Live Scan Measurement with Live representation No data record is possible in this mode e Settings Setting of date and time e Exit Power off the device and shut down the integrated PC module Via a touchpad on the top of your device you can select and confirm your appropriate operating mode OK
43. to go back to the selection menu e Delete Scan Image The current selected measurement will be deleted if you confirm the following message with Yes Following you will go back to the menu Ground Scan e Use GPS Navigation Start the navigation to the stored GPS data from this measurement After you confirmed the this option you will see a representation like in figure 26 If the GPS Receiver have no or insufficient data the message Searching for Satellites will appear and the programm is waiting until sufficient data is available Ground Scan GPS Navigation 544 9322 N 5100 6523 N 9988 7756 E 1227 5981 E Figure 26 GPS Navigation If sufficient satellites and their data are available the navigation will start The arrow indicates you in which direction you have to walk to reach the selected measured field In the upper left corner you can see your current position and behind in parenthesis the destination point is displayed On the lower left side you can read the distance to your destination point This indication is only correct if sufficient satellites are available and OKM Ortungstechnik GmbH www okm gmbh de 8 Operating Modes 31 you do move forward Only by moving and with the corresponding data the direction and distance of your destination can be determined You can press any key to come back to the selection menu e Back To Ground Scan Menu You go back to menu Ground Scan OKM Ortungstechnik GmbH www okm
44. ves and earth interferences in blue color Beware that miner OKM Ortungstechnik GmbH www okm gmbh de 8 Operating Modes 20 Figure 23 Graphical Representation of a Measurement in Operating Mode Ground Scan alisations of the ground are also shown in red color How you can differentiate minerals and mineralisations from real metals you can read in section 11 1 on page 45 or in the manual of your software program It is absolutely necessary to read section 11 2 on page 47 where the principle procedure of a graphical measurement is described 8 2 2 Browse Scans After confirm menu option Browse Scans with the key Activate Operating Mode you will see a list of all stored measurements like represented in figure 24 Ground Scan 1 2 01 01 2004 07 29 Figure 24 Select Stored Measurement Select the measurement which you like to see with the keys Previous Operating Mode and Next Oper ating Mode Every measurement with GPS data is indicated with the additional lettering GPS Only these measurements are convenient for the GPS navigation For the selected measurement the following options represented in figure 25 are provided OKM Ortungstechnik GmbH www okm gmbh de User s manual eXp 5000 30 Ground Scan Delete Scan Image Use GPS Navigation Back To Ground Scan Menu Figure 25 Submenu Browse Scans e View Scan Image The selected measurement will be displayed once again Press any key
Download Pdf Manuals