LegMaster
Contents
1. COUDES Li ack SOM ee do Oe SS He a oe eo 9 nesvplings esconde SE eee eet oS bho oS ot oS od owe S dul deem bots d 9 Goepel Leg holder 4 544 473 10 Components suis rn hd eS E doe Aa paced wd es dies 10 Assemb PRE EN D ER F E E E a Aa E S 10 Attaching Removing pads 2a u HR OR GR e n TR OR od 11 Intermediate BOE sco sr ox ace dca n ERE RR Bw Ro RE DR RR MER OR 11 Upper Bo SECIDIT qs 2404 4 ny iode ne AL Ee d 11 Lower leg section Goepel leg holder 2222222 11 Adjusting the LegMaster 4 sura deena sacha Rea CR C p AC 12 Raise Lower Abduct ud pace awh ee Say eue one US ARE dto 12 Angling the carrying arm meds x eo e ao d adepto Rae vos 12 Care Cleaning and Disinfection CONG S s dd deo do rear iN odo eae eas 13 e 13 BID T P 13 Service and Repair Work cesser koe ro een ah ren 14 Scrap Disposal 4 2112 Sese Ua ER SEWER PR ea ore a aoe He Ror SEES Ss 14 d MMC EP amp we re ee Bed 14 Overview LegMaster 4 544 526 15 LegMaster User Manual 4 900 876 03 02 Contents 2 LegMaster User Manual 4 900 876 03 02 TRUMPF Important Information 1 Important Information Products of the TRUMPF Medizin Systeme GmbH are manufactured to give a long and trouble free service life Development design and production by TRUMPF Medizin Systeme GmbH have been certified in accordance with DIN ISO 9001 This guarantees highest quality and a long service
2. When operating the operating table with the LegMaster collisions may occur when adjusting the operating table components and the LegMaster Watch the course of the adjustment carefully ATTENTION Remove the upper leg sections 73 5 before swinging upwards Support the main arm with the hand before opening the locking lever and swivelling the arm 1 Pull the locking lever 73 11 outwards 2 Setthe LegMaster upper joint 73 6 1 has a ball bearing and can also be swung horizontally NOTE When the leg sections are lowered they lock into a horizontal position for safety purposes This can be bypassed by pulling out the lever 73 13 3 Bring the locking lever 73 11 into a clamping position The carrying arm 73 6 can optionally hold the lower leg section 73 1 73 2 or the Goepel leg holder 76 and be angled up or down CAUTION Hold the carrying arm 73 6 before loosening the cam lever 73 10 The leg section 73 1 73 2 the Goepel leg holder 76 must be supported during the adjustment 1 Pull the cam handle 73 10 downwards 2 Bringthe carrying arm 73 6 with the leg section Goepel leg holder into the desired angled position 3 Bring the cam lever 73 10 into a clamping position LegMaster User Manual 4 900 876 03 02 TRUMPF Care Cleaning and Disinfection 3 Care Cleaning and Disinfection Care Cleaning Disinfection CAUTION Remove the power plug before starting al
3. onto the mushroom type locking studs 73 12 2 Press the leg section onto the main arm 73 6 until it audibly slots in Removing 1 Pull the ball headed pin 73 7 out of the main arm 73 6 and hold it 2 Remove the leg section 73 5 either in an upward direction or downwards between the main arms 73 6 Attaching 1 Turn the ball headed pin 73 4 ball grip screw 76 5 to the left 2 Press the holding catch 73 16 upwards and slide the lower leg section 73 1 73 2 Goepel leg holder 76 onto the carrying arm 73 9 3 Turn the ball headed pin 73 4 ball grip screw 76 5 to the right until the lower leg section 73 1 73 2 Goepel leg holder 76 is fixated CAUTION Before use check that the lower leg section Goepel leg holder is securely fitted to the carrying arm Removing CAUTION Heavy weight Hold the part being removed securely before pulling it out 1 Loosen the ball headed pin 73 4 by turning it to the left 2 Press the holding catch 73 16 upwards and slide the lower leg section 73 1 73 2 Goepel leg holder 76 off the carrying arm 73 9 3 Put the lower leg section Goepel leg holder down in a safe place LegMaster User Manual 4 900 876 03 02 LegMaster 4 544 526 2 4 Adjusting the LegMaster Raise Lower Abduct Angling the carrying arm CAUTION Only loosen the operating elements in order to make adjustments tighten them immediately afterwards ATTENTION
4. with his instructions 03 02 TRUMPF Medizin Systeme GmbH TRUMPF ATTENTION WN This User Manual apply to the following sales units LO QMOSIOP Tm m 4 544 526 Intermediate pad for LegMaster 4 544 547 Goepel leg holder for LegMaster 4 544 473 LegMaster User Manual 4 900 876 03 02 LegMaster User Manual 4 900 876 03 02 TRUMPF Contents m w N 2 1 2 2 2 3 2 4 Contents Important Information Proper Use of the Equipment ease eed op e ears nte a e E ease 3 Explanation of Symbols 4 42500 Sae hoec roe ww seek dew 4 Safety Ts FUCO acu puo Sopas d Cae po cO EROR RRA OR OR UR da We ci 5 General oo ee Rae wae De a dG tok Ape d rd Odo Be Pues d Sco 5 Changing position do d L RAR dee RUE OTRAS 5 Environmental Protection ss acp sco ia p Ro cR on RO ARE Rc RR E 6 Protection against Infection 244 sss 4454054 Gee ROC Ra ee ea eda d a 6 CIT CT fe Ba oe Gs we BG eS ES SS ee ne Guen 6 Textual representation sosse mig saat eee de deo eke eRe dew owt ae 6 TOSS cag haa a ac ACER ae A RR a a eddie den Cho s oC a o AR dec o 6 LegMaster 4 544 526 Components oe doa sace Rep a qup a pd R RR a CI aV tie Ra Tati dote 7 Rodielugenes 2 2 2422 dae ease XP TaduquemAqUE sq I ERR SUE 8 Lodding Capaci eros e scetur ied wap Nob eats oy Suck ed gres a cab EM arte 8 Coupling poll uuo ap ra rero hes RIPE ey rede 8 Coupling and Uncoupling oua dcr deno oer oco ee Lh OE Red 9
5. LegMaster User Manual This product corresponds to design class 1 within the meaning of the European Medical Device Directive MDD 93 42 EEC July 1993 Appendix 9 and the German Medizin Produkte Gesetz MPG Law on Medical Products August 1994 Appendix 9 The manufacturer declares that this product conforms to the essential requirements of the MPG Appendix 7 and this is documented by the CE sign C TRUMPF Medizin Systeme GmbH Postfach 1263 D 07303 Saalfeld Germany TRUMPF Medizin Systeme GmbH Carl Zeiss Stra e 5 D 07318 Saalfeld Germany Sales and Telephone 49 3671 5 86 0 Distribution Telefax 49 3671 58 61 65 Service Telephone 49 3671 58 61 72 49 3671 58 61 76 Telefax 49 3671 58 61 75 We are constantly working on further developments Therefore please understand that we must reserve the right to change the scope of the delivery in respect of the form equipment and technology at any time Reprinting copying or translating this document in whole or in part is forbidden without the express written permission of TRUMPF Medizin Systeme GmbH All rights under the copyright laws are expressly reserved by TRUMPF Medizin Systeme GmbH Within the bounds of the legal requirements the manufacturer is only then responsible for the technical safety characteristics of this apparatus if the maintenance repairs and modifications to this apparatus are performed by him or by someone appointed by him and in accordance
6. User Manual 4 900 876 03 02 Important Information 1 2 Explanation of Symbols Important information in this user manual is marked with symbols and keywords Keywords such as WARNING CAUTION or ATTENTION indicate the level of danger involved The symbols emphasise the message visually Additional symbols can indicate injury hazards or danger to life and limb The measures to prevent dangers arising must be implemented without fail WARNING INN 1 Danger to life and limb for example electric shock Risk of serious injuries and damage to property CAUTION Risk of injury and damage to property ATTENTION Risk of damage to property ver NOTE Useful additional information and tips LegMaster User Manual 4 900 876 03 02 TRUMPF 1 3 Safety Instructions General Changing position Important Information Please observe the following instructions Keep a log book for medical apparatus All services inspections and repairs are to be documented in this book Within the bounds of the legal requirements the manufacturer is only then responsible for the technical safety characteristics if the maintenance repairs and modifications are performed by him or by someone appointed by him and in accordance with his instructions and training TRUMPF Medizin Systeme GmbH is not liable for damage of any kind arising from the failure to perform inspections or through inadequate repairs modifications or main
7. bH Components must always be disposed of in a way that protects the environment i e it must be done in accordance with the currently valid legal regulations Dispose of as scrap metal sorted according to type Dispose of through a plastic recycling scheme LegMaster User Manual 4 900 876 03 02 TRUMPF Overview LegMaster 4 544 526 6 Overview LegMaster 4 544 526 4 544 526 73 1 73 2 73 3 73 4 73 5 73 6 73 7 73 8 73 9 73 10 73 11 73 12 73 13 73 14 73 15 76 7 76 8 4 544 473 Lower leg section right hand Lower leg section left hand Standard rail lower leg section Locking mechanism lower leg section Upper leg section Main arm with standard rail Locking mechanism upper leg section ntermediate pad 4 544 547 Carrying arm for holding the lower leg section or the Goepel leg holder Lower leg section adjustment cam handle LegMaster adjustment locking lever Holder for upper leg section mushroom type locking studs Lever for safety lock Coupling point upper leg section Locking handle Goepel leg holder right hand 4 544 473 Goepel leg holder left hand 4 544 473 LegMaster User Manual 4 900 876 03 02 15 TRUMPF Medizin Systeme GmbH Postfach 1263 D 07303 Saalfeld Germany Telephone 49 3671 586 0 Telefax 49 3671 58 61 65 e mail info de trumpf med com www trumpf med com LegMaster User Manual 4 900 876 03 02
8. e recommended care and cleaning of the pads in order to maintain their electrically conductive properties as per DIN EN 60601 1 Dispose of all left over cleaning and disinfection materials and any residues thereof in a safe manner which does not harm the environment Ensure that this document is disposed of in a way which does not harm the environment Comply with all the stipulations concerning cleaning disinfection and sterilisation Follow the instructions in this manual concerning cleaning disinfection and sterilisation procedures and the substances to be used therefor The operating tabletops and the patient positioning equipment must be covered with sterile material before use Devices and fitments must be cleaned and disinfected before being handed over to service technicians for maintenance and repair work Pads which no longer fulfil the requirements concerning hygiene and protection against infection must be replaced 1 4 Glossary The following terms and abbreviations are used in this user manual Textual Number in brackets Number code for illustrations representation 50 Referencing text to graphics Terms Operating Table Tabletop with additional sections leg back and head sections ect Operating Table seat section without other fitments Top Fitments leg back head section adapters section extensions ect Components Standard rail Fixing rails for accessories fitments Coupling point Separable joints between
9. l care cleaning or disinfecting work Ensure that no motorised movements can take place ATTENTION Do not use cleansers or disinfectants that are abrasive erosive contain halogens and peracetic acid The care of the fitments is limited to regular cleaning disinfection with suitable substances The following cleansers are permitted Stainless steel or aluminium parts all commercially available stainless steel cleansers Plastic parts all purpose cleansers on a weak alkaline base active cleaning ingredients tensides and phosphates Pads all purpose cleansers on a weak alkaline base active cleaning ingredients tensides and phosphates All commercially available substances conforming with the requirements of the hygiene regulations in the hospital LegMaster User Manual 4 900 876 03 02 Service and Repair work 4 Service and Repair work Scrap Disposal Metals Plastics For service work and repairs please contact TRUMPF Medizin Systeme GmbH Service Telephone 49 3671 58 61 72 49 3671 5861 76 Fax 49 3671 5861 75 Recommended maintenance interval 1 year We only permit our products to be maintained and serviced by trained service personnel Using service experts of TRUMPF Medizin Systeme GmbH will ensure that our products will give you many years of consistent reliable service We recommend that you take out a service contract with TRUMPF Medizin Systeme Gm
10. life easy operation functional design and optimisation for the intended purpose The products of the TRUMPF Medizin Systeme GmbH fulfil the requirements of the Medizinproduktegesetz MPG Law on Medical Products and bears the CE sign Please read this user manual carefully from the beginning in order to familiarise yourself step by step with the many and varied functions Reference is made to any residual dangers in the appropriate sections 1 1 Proper Use of the Equipment The JUPITER MARS and SATURN Select Select L operating tables are intended for the following purpose in conjunction with this operating table component Holding patients during the operation induction of anaesthesia operation recovery from anaesthesia Transporting the patient on the tabletop without column from a patient transfer unit to the operating theatre from the operating theatre to the patient transfer system The operating tabletops must be covered with sterile material before use Accessory devices for use with or on tabletops or accessories may only be used for the intended purpose described in this user manual Intended use of the includes following the instructions in this user manual Any other use is regarded as incorrect usage The supplier manufacturer is not liable for damage to property or injury to persons resulting from incorrect operation of the table or putting it to an improper use LegMaster
11. n a horizontal position safety lock with the locking lever under tension Only in the pad area outside the metal spars CAUTION Danger to the patient The stated loading capacity of the section segments must not be exceeded The values stated apply to an evenly distributed load area load including accessories without longitudinal displacement of the lower leg section 73 1 73 2 Upper leg section 15 kg per side patient weight of 135 kg Lower leg section 10 kg per side Goepel leg holder 10 kg per side Standard bar 30 Nm CAUTION Danger to the patient Do not let the patient climb onto the LegMaster in order to get into the rectal position risk of overload Positioning may only take place from the prone position Upper leg section double clamp wide LegMaster User Manual 4 900 876 03 02 TRUMPF LegMaster 4 544 526 2 1 Coupling and Uncoupling Coupling CAUTION Tighten hand tight LA Test the connection before use 1 1 Turn the locking handle to the left stop position 2 2 Press the coupling points of both fitments together until the coupling point slots in 3 3 Tighten the locking handle until there is no more play in the coupling point p CAUTION A NE Hold the part being uncoupled securely before pulling it out Because of the heavy weights involved never uncouple more than one fitment at a time 1 1 Turn the locking handle to the left stop position 2 2 Press
12. tenance The edges of the pads are flush when the operating table components have been attached properly The pads do not provide adequate protection against decubitis during lengthy operations Use additional gel mats The patient must be actively supported when the position is adjusted Released elements may move autonomously Check that fixing screws are seated properly Accessories with removable pads must not be carried by the pads Every change of position must be performed in a controlled and responsible manner Pay close attention to all electrically assisted functions and movements in order to exclude the possibility of a risk to the patient arising or damage occurring to the equipment or to the furnishings Only approach zero position or handover position if there is no risk of collision Watch the approach to the zero position or the handover takeover position carefully until the end position has been reached Take particular care when lowering the operating table in order to avoid the risk of damage to any operating equipment located under the tabletop In addition beware of the risk of injuries to persons LegMaster User Manual 4 900 876 03 02 Important Information Electricity Environmental Protection Protection against Infection The electrically conductive properties of the LegMaster comply with the legal requirements if the pads supplied are used and properly secured Please perform th
13. the fitments 6 LegMaster User Manual 4 900 876 03 02 TRUMPF LegMaster 4 544 526 2 LegMaster 4 544 526 Components The LegMaster 73 consists of the following components 4 544 526 73 1 732 73 3 73 5 73 6 73 7 73 8 73 9 73 10 73 11 73 12 73 13 73 14 73 15 76 7 76 8 Lower leg section right hand Lower leg section left hand Standard rail lower leg section Locking mechanism lower leg section Upper leg section Main arm with standard rail Locking mechanism upper leg section ntermediate pad 4 544 547 Carrying arm for holding the lower leg section or the Goepel leg holder Lower leg section adjustment cam handle LegMaster adjustment locking lever Holder for upper leg section mushroom type locking studs Lever for safety lock Coupling point upper leg section Locking handle Goepel leg holder right hand 4 544 473 Goepel leg holder left hand 4 544 473 LegMaster User Manual 4 900 876 03 02 7 LegMaster 4 544 526 Function Radiolucence Loading capacity 260 260 73 5 450 e 73 260 732 Coupling point The LegMaster is a four part leg section with lifting and abduction mechanism It is used on the JUPITER MARS and SATURN Select Select L operating tables The LegMaster may only be attached to the coupling points stated in these Instructions for Use CAUTION Danger to the patient Patients may only be transported on the LegMaster i
14. the locking handles upwards and at the same time lift the fitment slightly and pull it out LegMaster User Manual 4 900 876 03 02 9 LegMaster 4 544 526 2 2 Goepel Leg holder 4 544 473 Components The Goepel leg holder consists of the following components 76 1 Pad 76 2 Ball joint can be turned inclined through 180 76 3 LegMaster socket 76 4 Tension lever ball joint 76 5 Ball grip screw 76 6 Velcro strip 76 7 Goepel leg holder left hand 76 8 Goepel leg holder right hand Assembly The distance between the Goepel leg holders and that between the Goepel leg holder and seat section can be adjusted as follows Put the Goepel leg holders on the opposite sides 76 right Goepel leg holder 76 7 76 8 on the left carrying arm and vice versa 73 9 2 73 9 1 Turn the Goepel leg holder 76 on the carrying arm 73 9 1 The Goepel leg holder is turned through 180 and slid onto the carrying arm 2 Turn the pad 76 1 in the ball joint 76 2 the right way round Longitudinal displacement of the Goepel leg holder 76 on the carrying arm 73 9 LegMaster User Manual 4 900 876 03 02 TRUMPF LegMaster 4 544 526 2 3 Attaching Removing pads Intermediate pad Upper leg section Lower leg section Goepel leg holder 73 16 The intermediate pad 4 544 547 73 8 is secured with a Velcro strip Attaching 1 Put the upper leg section 73 5