1. Driver Configuration 24 To operate properly the driver must be configured to recognize the Parallex subsystem The hpsadmin utility allows you to view or modify the driver configuration if you change the configuration in any way During driver installation hpsadmin is initiated automatically however any time after the driver is installed you can run hpsadmin to change the existing configuration The configuration is downloaded to the driver during the boot process Any time you change the driver configuration you must reboot the system for the new configuration to take effect NOTE For movement through hpsadmin use the down arrow key to advance the up arrow key to back up within a menu the enter or return key on some systems to make a selection and the escape key to save any new values selected within a menu and return to the previous menu a From the Driver Configuration menu presented after the DTC Subsystem SETUP screen press 1 to indicate that you have one Parallex adapter connected to your host computer b In the same menu press O to indicate that you wish to view or modify the configuration of the Parallex adapter c Select the Modify field to advance to the Modify Adapter Configuration menu Within this menu youll select e The Parallex adapter model installed e Which parallel port addresses to use There are three standard options to choose from 278 378 and 3BC e The interrupt vector number to u
2. e hps_log to display the current log information from the Parallex subsystem Installation e hps load cn etc tcs20XX dnl to download the operational software to the Parallex subsystem e hps dloop to test the host to Parallex subsystem interface This command will take approximately 30 seconds Y Did any of these commands fail If yes STOP This probably indicates that your parallel port is either not reliable is set up wrong is not capable of bi directional operation or is not truly bi directional Check your hardware setup and descriptions Congratulations If you ve gotten this far your Parallex subsystem should be fully functional If not go back and check for any of the previous error messages from the driver e For SCO examine the file usr adm messages e For UnixWare run crash and enter the command panic Booting the System The hps load utility didn t execute and an error may have occurred when installing the Parallex subsystem Verify that e Thehps load utility is present in etc e File permissions are correct read execute rx should be set e Ifhps load does not exist reinstall the Parallex subsystem software The hps load utility executes but tcs20XX dnl can t be found and an error may have occurred when installing the Parallex subsystem The error message should look similar to hps load Cannot open file etc tes20XX dnl Verify that e The file tcs20XX dnl is present in etc
3. and powered on 2 RTS output Flow control to enable remote device to send data 3 SG Signal return NOT chassis ground 4 TXD output Serial data out from Parallex adapter to remote device 5 RXD input Serial data in from remote device to Parallex 28 Hardware Installation adapter 6 SG Signal return NOT chassis ground 7 CTS input Flow control to enable Parallex adapter to send data on TXD 8 DTR output Signals remote devicethat Parallex adapter is attached and powered on Ta E F pin 1 Figure 6 1 RJ 45 to RJ 45 Straight Through Cable Configuration Figures 6 2 and 6 3 illustrate the pinout signal configurations required for RJ 45 to DB 25 DTE and DCE data communication equipment cables respectively Figure 6 4 shows the configuration required for a crossover null modem cable terminated with RJ 45 connectors RJ 45 Plug Pin Number Signal 1 2 3 6 4 5 7 8 DB 25 Plug Pin Number Signal Figure 6 2 RJ 45 to DB 25 Terminal DTE Cable Diagram Hardware Installation 29 RJ 45 Plug Pin DB 25 Plug Pin Number Signal Number Signal 1 2 3 6 4 5 7 8 Figure 6 3 RJ 45 to DB 25 Modem DCE Cable Diagram 27 Figure 6 4 RJ 45 to RJ 45 Null Modem Cable Configuration 30 Hardware Installation Chapter 7 Parallex Utility Programs The Parallex Menu Program For ease in using the Parallex serial communications subsys
4. e The file permissions are correct read r should be set e ftcs20XX dnl does not exist reinstall the Parallex subsystem software The raw device dev rhp n or dev dtc n could not be opened The error message should look similar to hps load Cannot open device dev rhpO Verify that e The file dev rhp n or dev dtc n is present If not an error occurred in installation e Reinstall the driver 39 e f dev rhp n or dev dtc n is present check the device entry Verify that e The file permissions are correct read write rw should be set e The Parallex subsystem may not have initialized when the system booted Run the hps_log utility If this returns an error go back to the Installation section of this chapter and check your board installation If the hps_log utility succeeds then you just need to load the device as follows e Reset the Parallex adapter by running hps_reset Download the TCS with hps load cn etc tcs20XX dnl e Download the port configuration with hty load f etc hty config You can execute these utilities manually or through hpsadmin e You may not have set up the parallel port configuration correctly Check your hardware documentation and refer to the driver installation chapter of this manual e Ifyou have no success record any error messages and contact a SYSTECH technical representative The hps load utility is running and an error appears on the console determ
5. 128K bytes of flash memory e 256K bytes of static RAM e Green status LED e Environmental specifications as follows e Operating 0 C to 40 C e Storage 10 C to 70 C e Humidity 10 to 90 noncondensing e Appropriate power supply for either 110V or 220V application e 105 to 129 VAC 60 Hz e 198 to 242 VAC 50 Hz e Ports e TIEFE 1284 A peripheral level 2 host port e DB 25 printer port e 8 pin RJ 45 serial ports Pass Through Parallel Port The Parallex s pass through parallel port is compatible with IBM personal computer parallel printer ports as shown in table A 1 Table A 1 Pass Through Parallel Port Pinouts Pin Number Signal Name STROBE D 0 YN DU AU NJ F2 N ololololololol Appendix A Parallex Subsystem Specifications 45 8 D 6 O 9 D 7 O 10 ACK 11 BUSY 12 ERROR 13 SELECT 14 AUTOFD O 15 FAULT 16 INIT O 17 SELECTIN O 18 GND 19 GND 20 GND 21 GND 22 GND 23 GND 24 GND 25 GND Parallel Host Cable The cable used to connect the Parallex adapter to your computer s parallel port must match the pinouts listed in table A 2 Use the parallel host cable provided in your Parallex starter kit if possible If your computer s parallel port is not a DB 25 obtain a cable with the appropriate connector which meets the specifications given Table A 2 Parallel Host Cabl
6. Ensure that your computer s parallel port is configured for bi directional operation refer to your host system user manual for detailed information 8 Shut down your computer 9 Install the Parallex hardware as described in chapter 6 10 Reboot your system Downloading the Terminal Control Software to the Parallex Hardware During the kernel build process utilities will modify directory etc idrc d and file etc inittab to add entries which will download the Parallex adapter and configure the hty devices Thus after the kernel is built the system rebooted and you have entered multi user mode the system will automatically e Download the Terminal Control Software file to the Parallex subsystem using the hps load utility e Initialize ttymon login services on each of the Parallex ports you ll enable them manually as described in the next section NOTE Following download the Parallex adapter s LED will blink slowly about once per second to indicate that it has been downloaded and is operational If this does not occur download failed Do not proceed refer to chapter 8 for troubleshooting UnixWare Driver Installation 25 Enabling Channels for Login Refer to sysadm ADM in your UnixWare system administrator s manual for more information about the following instructions 1 Log onto the system as root 2 Atthe system prompt type sysadm When the Main menu is displayed select ports and press the enter or retur
7. and that matches the pinout shown in appendix A If the power supply provided in your starter kit has a detachable cord connect the cord to the power supply Then connect the small round power supply connector to POWER on the Parallex adapter Connect the power supply to an appropriate AC power source At this point you ll notice that the Parallex adapter s green LED is illuminated The LED will blink to indicate status conditions as follows e Initially as the Parallex adapter s self test is performed the LED will blink quickly e When self test completes it takes approximately 20 seconds the LED will blink a heartbeat pattern of two blinks in quick succession then a pause The heartbeat pattern which indicates that the Parallex subsystem is ready to be downloaded will repeat until downloading occurs e Once downloaded the LED blinks slowly about once per second indicating that the Parallex subsystem is operational Hardware Installation 27 4 Connect cables terminated on at least one end with RJ 45 connectors to as many of the serial ports labeled 0 through 3 7 15 or 31 depending on the model of Parallex subsystem as desired for your environment Tables defining required cable pinouts for use with the Parallex adapter appear later in this chapter Connect the free ends of the serial cables to the serial devices you are using terminals modems printers etc 5 Ifusing a parallel printer connect a cable te
8. b In the same menu press O to indicate that you wish to view or modify the configuration of the Parallex adapter c Select the Modify field to advance to the Modify Adapter Configuration menu Within this menu you ll select e The Parallex adapter model installed SCO Driver Installation e Which parallel port addresses to use There are three standard options to choose from 278 378 and 3BC e The interrupt vector number to use There are two standard options 5 and 7 e The type of parallel port There are two options PS 2 and Compaq Select PS 2 unless your host system is a Compaq NOTE The menus provide reset and help options Selecting reset resets the screen to the default values Selecting help displays help information d Press the escape key to return to the Driver Configuration menu Ensure that the configuration you established for the Parallex subsystem is correct by selecting the View option e Exitthe View menu by pressing the escape key f Press the escape key again to initiate the installation process g A message will tell you that the driver modules are being installed UNIX minor device numbers are assigned sequentially from 0 For example if your configuration is for an SCS 2008 the UNIX minor device numbers would be as shown in table 4 1 Note that port hty08 in the example is a printer port Parallex Adapter UNIX Minor On board dev hty entries Devices Channel 0 0 8 0 8 dev hty00
9. e For SCO cp unix unix backup e ForSVR4 cp stand unix stand unix backup Install the Parallex driver On SCO systems you ll install by running the custom utility On SVR4 UnixWare systems you ll run pkgadd To install the new driver you will need to know The model number of the Parallex adapter to be installed The type of parallel port being used PS 2 standard or Compaq The parallel port address The parallel port interrupt level Follow the on line driver installation instructions including rebuilding the kernel Chapter 4 contains detailed driver installation instructions for SCO chapter 5 for UnixWare Shut down your computer NOTE Ensure that your computer s parallel port is configured for bi directional operation refer to your host system user manual for detailed information Install the hardware components as follows e Use the parallel host cable provided to connect the Parallex adapter COMPUTER port to your computer s parallel port Quick Start Instruction Summary 13 e Connect the Parallex adapter to an AC power source using the power supply provided with your Parallex subsystem Chapter 6 contains detailed hardware installation instructions 6 Power up your Parallex subsystem The LED will blink quickly during self test When the LED blinks a heartbeat pattern the Parallex subsystem has passed self test and is ready to be downloaded 7 Reboot your system The Parallex subsystem will then be
10. hty08 10 After the drivers are configured the SCO custom program will ask you three questions Answer y yes to each of the following e Create a new kernel e Use the new kernel to boot by default e Rebuild the kernel environment Refer to idbuild ADM in your SCO UNIX system administrator s reference manual for more information Exit the custom program by selecting the Quit option and then confirm by pressing the enter or return key after highlighting the yes option NOTE Ensure that your computer s parallel port is configured for bi directional operation refer to your host system user manual for detailed information 11 Shut down your computer 12 Install the Parallex hardware as described in chapter 6 13 Reboot your system SCO Driver Installation 19 Downloading the Terminal Control Software to the Parallex Hardware During the kernel build process utilities will modify directory etc idrc d and file etc inittab to add entries which will download the Parallex subsystem and configure the hty devices Thus after the kernel is built the system rebooted and you have entered multi user mode the system will automatically e 1 Download the Terminal Control Software file to the Parallex subsystem using the hps load utility e 1 Download the port configuration to the Parallex subsystem using the hty load utility NOTE Following download the Parallex adapter s LED will blink slowly about once per
11. second to indicate that it has been downloaded and is operational If this does not occur download failed Do not proceed refer to chapter 8 for troubleshooting Enabling Channels for Login Refer to sysadmsh ADM and enable C in your SCO UNIX system administrator s manual for more information about the following instructions To configure and enable individual channels ports for logins you will first need to update the Terminal Control database to include the hty device names and then enable the ports for login The steps below explain how to do this NOTE The device name specifies both the device and the individual port s to be enabled NOTE Use the escape key to toggle between the currently displayed screen and the previous screen the space bar to move through the options and the enter or return key on some systems to select the option 1 Logonto the system as root 2 Atthe system prompt type sysadmsh Select the Accounts menu then select the Terminal option 4 From the Terminal menu select Create When the Create menu is displayed move to the line for entering the Terminal Device Type the number of the first terminal device port you wish to configure for login for example hty00 followed by the enter or return key You may change the maximum failed login count or the delay between login attempts if you wish however for most applications the defaults may be used 6 Answer yes to the Confirm Change o
12. subsystem specifically the following are covered e Quick start instructions Disabling your existing parallel printer driver Installing the device drivers and Parallex utilities Installing the Parallex hardware Testing your system to ensure proper installation and operation Handling errors and troubleshooting System specifications For Reference To save time in cases where you may have questions about your Parallex subsystem please take a few minutes to fill out the information below This information will be requested if you call for help in troubleshooting your system or if you are interested in purchasing additional SYSTECH equipment to enhance your system capabilities Your Parallex Subsystem 9 Parallex host adapter model SCS 2004 4 port SCS 2008 8 port SCS 2016 16 port SCS 2032 32 port Ooo wv Parallex host adapter serial number Reseller contact Phone number Package Contents The Parallex subsystem consists of the following components Hardware e Parallex adapter e Parallex power supply some power supplies have a detachable power cord e Host connection cable equipped with DB 25 connectors e Parallex stand Software e Diskettes containing e Parallex Device Driver Software e SYSTECH s Terminal Control Software TCS e Utilities and on line manual entries Terminal Control Software SYSTECH s Terminal Control Software TCS allows the Parallex serial communications subs
13. Parallex Subsystem Installation and Operations Guide gt SYSTECH CO RP ORATION Document number 80 000963 6 Revision B Parallex Subsystem Installation and Operations Guide Document part number 80 00963 6 Revision History Date Revision Description 3 25 94 A Initial production release 4 15 94 B Clarified the installation instructions Created 1994 and Protected Under the U S Copyright Act of 1976 Copyright O 1994 SY STECH Corporation All Rights Reserved This document is subject to change without notice Unplug is a registered trademark of SYSTECH Corporation Etherplex is a trademark of SYSTECH Corporation Parallex is a trademark of SYSTECH Corporation SCO is a registered trademark of The Santa Cruz Operation Inc Unix is a registered trademark of Unix System Laboratories Inc UnixWare is a trademark of Univel IBM is a trademark of International Business Machines Inc Agency Notifications FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this manual may cause harmful interference to radio communications Operation of this equipment in a residentia
14. be reported through the Parallex subsystem device drivers by the Parallex adapter resident operating system or Terminal Control Software Symptoms of fatal errors are e User terminal sessions stopped no longer accepting input or producing output e The Parallex adapter s LED is no longer blinking on and off slowly once per second e The entire Parallex subsystem appears to be halted Record any errors that displayed on your system console then check the following symptoms 42 Other Problems The Parallex subsystem resets itself during normal operation e Record any errors displayed on your system console Run the hpserrlog utility and record the results If the problem recurs contact a SYSTECH technical representative The terminal sessions stop or the subsystem appears to be halted e Record any errors displayed on your system console Run the hpserrlog utility and record the results e Runthehps log utility VY Does the Parallex subsystem hang If yes STOP There is probably an internal software error Kill the hps log utility then run the hps dump utility Reset the Parallex subsystem and resume operations If the problem recurs send the resulting dump file hpscore along with a list of the console messages and the results of hpserrlog to SYSTECH for analysis Appendix A Parallex Subsystem Specifications 43 Appendix A Parallex Subsystem Specifications Features e High performance 25 MHz 68360 microprocessor e
15. d hty load hps reset hps log hty stat hpsver hps dloop hps dump hty check LIMITATIONS 34 Parallex Utility Programs Hpsadmin uses the UNIX curses screen management libraries On some systems these routines may not properly support all ASCII terminals Hpsadmin was designed to use a minimal set of screen attributes to minimize these problems If you experience problems verify that your terminal type environment or shell variable TERM is properly set in the system or try different options on your terminal If these do not solve the problem you may still execute all of the Parallex utilities from the UNIX command line Parallex Utility Programs 35 Chapter 8 Troubleshooting Your Parallex Subsystem Before you call for support review this chapter to see if the symptoms exhibited by your system are described This chapter is divided into four sections Installation Booting Multi user Mode and Other Problems Installation The most common installation problems are associated with setting up the parallel port properly If you have installation problems work through the following sequence to diagnose the source of the problems 1 Start by removing the host to Parallex cable and shutting down your host system 2 Power up the Parallex adapter v Does it pass self test and does the LED blink in a steady heartbeat pattern boomp boomp boomp boomp If no STOP There is a problem with the Parallex adapter Contact your su
16. de Problems The system is up but no login prompt appears on the user terminal Verify that the terminal is functional Check the terminal mode settings For SCO systems ensure that the port was configured through sysadmsh and enabled with the enable command For UnixWare systems ensure that the port was enabled through sysadm Verify that the cabling from the Parallex subsystem to the terminal is correctly installed Check to see if a login prompt appears on any other terminal attached to the Parallex subsystem Avoid using RS 232 cables longer than what is defined by the EIA RS 232 specification excessive cable length may lead to data transmission errors Refer to the ELA RS 232 specification which defines the limits of cable lengths as described in total amount of picofarads Ensure that your RS 232 connectors are wired properly for your equipment see chapter 6 for wiring configurations Check for a good terminal connection using the hty check utility Check for the presence of modem signals using the hty stat utility and the channel status option Check the Parallex adapter for a failed port e Runhps log to the Parallex adapter You can execute this command manually or through hpsadmin See if there is a corresponding dev entry for the channel Verify that dev contains e Anhty entry for the channel e Correct mapping of the major minor numbers run hpsadmin to get device mapping e The correct file permission
17. downloaded NOTE Following download the Parallex adapter s LED will blink slowly about once per second to indicate that it has been downloaded and is operational If this does not occur download failed Do not proceed refer to chapter 8 8 Connect any terminals modems and or printers you plan to use then start using the ports Chapter 6 contains cabling information e On SCO systems Parallex devices are identified as dev hty00 through dev hty32 depending on the model of Parallex subsystem e OnSVR4 UnixWare systems Parallex devices are identified as dev hty hty00 through dev hty hty32 depending on the model of Parallex subsystem The printer port is the last port on the Parallex e SCS 2004 SCO dev hty04 UnixWare dev hty hty04 e SCS 2008 SCO dev hty08 UnixWare dev hty hty08 e SCS 2016 SCO dev hty16 UnixWare dev hty hty16 e SCS 2032 SCO dev hty32 UnixWare dev hty hty32 14 Quick Start Instruction Summary Chapter 3 Disabling the Printer Driver It is necessary to disable your existing parallel printer driver if installed before installing the Parallex device driver Some systems require you to actually de install the printer driver others allow you to disable its operation If the printer driver is not installed on your host computer disregard these instructions and proceed with the driver installation instruct
18. e Pinouts Pin Number Signal Name 1 0 1 HostClk H 2 Data 1 B 3 Data 2 B 4 Data 3 B 5 Data 4 B 6 Data 5 B 7 Data 6 B 8 Data 7 B 9 Data 8 B 10 PtrClk P 11 PtrBusy P 12 AckDataReq P 13 Xflag P 14 HostBusy H 15 NDataAvail P 16 NInit H 17 1284 Active H 18 Signal Ground 19 Signal Ground 46 Parallel Host Cable 20 Signal Ground 21 Signal Ground 22 Signal Ground 23 Signal Ground 24 Signal Ground 25 Signal Ground Source is H from host B bi directional P from Parallex adapter Appendix A Parallex Subsystem Specifications 47 Appendix B Tuning the Kernel Since the Parallex serial communications subsystem allows many users some of the kernel s tunable parameters may need to be increased to allow for more processes to support the additional users The NPROC and NREGION parameters are of particular importance Refer to the system administrator s reference manual provided with your system for details about these and other parameters that may need to be changed when the number of supported users is increased NPROC and NREGION are briefly defined below e NPROC specifies how many process table entries to allocate The value of NPROC depends on the number of processes that a user can create The valid range is between 50 and 200 e NREGION specifies how many region table entries to allocate It is recom
19. ectrical shock hazards inside Do not remove cover No user serviceable parts inside VORSICHT Um elektrischen schlag zu ver meiden mettallplatte nicht abnehmen Zugang zur bedienung nicht erforderlich Wartung nur durch qualifiziertes personal PRECAUCION Esta cubierta no debe abrirse Solo personal de servicio calificado No hay partes que puedan recibir mantenimiento por el usuario ATTENTION Ne pas enlever ce couvercle R serv au personnel autoris Il n y a pas de composant l interieur qui puisse tre remplac par l utilisateur ATTENZIONE Non rimuovere questo coperchio Scopritura Solo per personale addestrato e autorizato Nell interno non vi sono componenti che possono essere sottoposti a servzio dall utente o fuori fabbrica Your Parallex Subsystem Chapter 2 Quick Start Instruction Summary This chapter summarizes the steps required to install and begin using your Parallex serial communications subsystem Detailed instructions appear in the following chapters and are referenced below Once you become familiar with the process this summary will provide a quick installation and operation reference 1 On SCO systems de install your existing printer driver by running the custom utility and issuing the command mkdev parallel and selecting the Remove option if the parallel port is currently configured Chapter 3 contains detailed information about deinstalling drivers Make a backup of your kernel
20. ine what type of error occurred e Ifthe hps_load utility can t get the download file header information the error message should look similar to hps load Error reading etc tcs20XX dnl s header e Try to execute the hps load utility either by manually entering etc hps load cn etc tcs20XX dnl or through hpsadmin If the error occurs again it is probable that the download file etc tcs20XX dnl is corrupt in this case reinstall the Parallex subsystem software e Ifa write error occurred during the download sequence the error message should look similar to hps load Write error e Reset the Parallex subsystem by executing the hps reset utility and then the hps load utility You can execute these utilities manually or through hpsadmin or cycle power to the Parallex subsystem off and then on again e Ifyou have no success record the error and contact a SYSTECH technical representative The following error message appears on the console when you open any hty port WARNING HTY hty init Port configuration has not been downloaded The port configuration has not been downloaded to the Parallex adapter Do the following 40 Booting the System Reset the Parallex adapter by running hps_reset Download the TCS with hps load cn etc tcs20XX dnl Download the port configuration with hty load f etc hty config You can execute these utilities manually or through hpsadmin Multi User Mo
21. ions for your system De installing the Printer Driver with SCO On SCO systems you must de install the printer driver before installing the Parallex driver You ll use the SCO custom utility to de install the driver from the system kernel Follow these steps to remove the driver 1 Log onto the system console as root 2 Execute the command mkdev parallel 3 If the parallel port is currently configured select the Remove option Disabling the Printer Driver with UnixWare UnixWare does not allow you to de install the printer driver however your Parallex software will disable its operation automatically during the driver installation process During driver installation the Parallex software checks to see if the Ip printer driver is installed and if so whether either its I O address or IRQ number interrupt vector conflicts with that of the Parallex subsystem If there is a conflict the Parallex software disables the Ip driver operating at that I O address or using that IRQ number before completing the installation process If the printer driver is installed and its I O address or IRO number conflicts with that of the Parallex subsystem the software will display a message informing you that the printer driver is being disabled for that particular port You will no longer be able to use the native printer driver for direct connection to a printer but you can access the printer on any other native parallel ports through the na
22. l area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense Table of Contents Chapter 1 Your Parallex Subsystem Introduction SYSTECH s Parallex serial communications subsystem SCS offers advanced capability for connecting asynchronous devices terminals and printers for example to multi user computer systems The Parallex SCS is a complete hardware and software communications product which provides low cost intelligent serial communications for small and medium sized UNIX installations The Parallex SCS is bus independent eliminating the need for a dedicated bus specific host adapter board The Parallex subsystem handles all serial line discipline issues releasing the host computer from the high interrupt service burdens associated with traditional multi channel serial interfaces Each Parallex SCS subsystem supports up to 32 users depending on the model at speeds up to 115 2K baud A single cable connects the Parallex subsystem to your host computer s bi directional parallel port In addition the Parallex subsystem provides a separate pass through connector for continued output only parallel port operation NOTE Ensure that your computer s parallel port is configured for bi directional operation refer to your host system user manual for detailed information This manual describes how to install and use the Parallex
23. lowing hpsadmin description which is available to you as an on line man page explains operation of the Parallex subsystem menu program in more detail NAME hpsadmin menu interface to the Parallex configuration installation information and diagnostic utilities SYNOPSIS hpsadmin DESCRIPTION Hpsadmin allows the driver configuration to be modified and provides a menu interface to the Parallex utility programs There are two types of Parallex utilities system and diagnostics And there are two categories of system utilities administrative and information gathering The Parallex menu program provides a convenient method for entering the required and optional parameters for the utilities The main menu appears as follows Similar menus appear for the system and diagnostic selections 32 Parallex Utility Programs MAIN MENU Systech Configuration and Diagnostic Utility Modify Driver Config System Utilities Diagnostic Utilities Quit Help Display Menu of the System Utilities Once a utility is selected a screen similar to the following an example from the hps_log utility appears allowing you to specify or change the utility s parameters get specific help on the utility and execute the utility HPS_LOG Display Log and Supplementary Information From The HPS Host Adapter or Cluster Controllers Optional Parameters Enter Device File Name dev dtcO Clear log table upon completion of read N Ru
24. me of the driver to be removed dtc for the Parallex driver where indicated 1 Log onto the system console as root 2 Type the command pkgrm driver name then press the enter or return key The driver package that is currently installed will be displayed 3 When asked if you want to remove this package answer y yes Pkgrm will inform you when the package has been successfully removed 16 Disabling the Printer Driver Chapter 4 SCO Driver Installation For the SCO driver installation you will use components of your SCO UNIX system to complete the installation You should be familiar with SCO UNIX before installing the driver NOTES The link kit must be installed on your computer system before you can install the drivers Refer to the system administrator s manual provided with your computer system for more information about installing device drivers with a link kit Review the following information before you begin the installation process Some of the information you will be required to provide may require consulting with your system administrator You may wish to prepare a configuration worksheet containing the following information which will be requested during the installation the model number of the Parallex subsystem SCS model the parallel port address to use and the parallel port interrupt number to be used Installing the DTC Subsystem Runtime Package The runtime version diskette provided with y
25. mended that this value be set to approximately 3 5 times the value of NPROC The Parallex subsystem driver does not use the host system s character list buffers NCLIST or the system s streams facilities so parameters associated with these facilities do not need to be modified Tuning the Kernel Under SCO Under SCO UNIX the configure ADM command is used to tune the kernel To find the current value of a parameter type the following replacing the words that appear in italics with the actual parameters values you are using cd etc conf cf d configure y parameter To set the parameter to a new value type configure parameter new value To rebuild the kernel with the new values type link unix Tuning the Kernel Under UnixWare Under UnixWare the idtune and idbuild commands are used to tune the kernel To find the current value of a parameter type the following replacing the words that appear in italics with the actual parameters values you are using cd etc conf bin 48 Tuning the Kernel Under SCO idtune gc parameter To set the parameter to a new value type idtune mc parameter value To rebuild the kernel with the new values type idbuild B Appendix B Tuning the Kernel 49 Index B Bi directional port 13 19 25 27 38 Blinking 14 20 25 27 37 C Cables host computer 10 13 27 46 printer 28 46 RJ 45 28 45 RS 232 28 41 Configuratio
26. n 18 24 31 D DB 25 10 29 45 46 De installation 13 15 Device driver 10 11 15 17 23 Device names 19 20 25 dtc 11 H Heartbeat 14 27 37 hps 31 hpsadmin 11 17 23 31 32 hty 11 I Installation 13 15 17 23 27 37 Interrupt level 13 17 23 K Kernel backup 13 Kernel tuning 48 L LED 14 20 27 37 38 45 Load download 10 14 18 24 27 Login 20 26 50 Index P Parallel Pass through feature 9 45 port Bi directional 9 13 19 27 38 Compaq 13 19 24 PS 2 13 19 24 port address 13 19 23 24 37 port interrupt 13 19 24 Pinouts 28 R rhp 11 RJ 45 28 45 S SCS 2004 2008 2016 2032 9 14 Self test 10 14 27 37 Serial 28 45 Stand 27 TCS 10 20 25 40 U Utilities diagnostic 31 32 hps dloop 32 34 39 hty check 32 34 41 system 31 administration 31 hps load 20 25 31 34 39 hps reset 31 34 40 hty load 20 31 34 information gathering 32 hps dump 32 34 hps log 32 34 38 41 hps_ stat 32 34 hpserrlog 32 34 43 hpsver 32 34 Index 51
27. n key When the Service Access Management menu is displayed select the port_services option Move the cursor to the enable option then press the enter or return key Dy BOT Wm lon A list of all ports that can be enabled for a login service will be displayed The ports that are associated with logins on Parallex subsystem ports have a Pmtag of htyscs Move the cursor to each of the selected ports and use the F2 function key to mark each port that is to be enabled After marking all the ports press the enter or return key to enable login sessions on all the marked ports 7 Press the F7 key to display the Command menu then choose the Exit option 26 UnixWare Driver Installation Chapter 6 Hardware Installation This chapter explains how to install the Parallex subsystem hardware components and provides connector pinout and cable configuration information Hardware Connections Have the following items available then install the hardware as described Parallex adapter Parallex power supply Parallex adapter stand Parallel host connection cable Using the parallel host cable provided as part of your Parallex subsystem connect one end to COMPUTER on the Parallex adapter Connect the other end to your host computer s bi directional parallel port If the parallel port connector on your computer is not a DB 25 you ll need to obtain a parallel cable terminated with a connector that is appropriate for your computer
28. n Quit Reset Help Enter the Full Pathname for the Host Adapter Device The following menu movement keys apply to all menus UP ARROW Moves to the next field above the currently highlighted field DOWN ARROW Moves to the next field below the currently highlighted field ENTER Goes to the submenu which is designated by the currently highlighted field Or moves to the next field below the currently highlighted field lt ESC gt Returns to the previous menu Each menu includes a HELP option that describes the actions available from that menu In addition context sensitive help is available for each field of the display This help information is displayed in the border of each screen Parallex Utility Programs 33 QUIT Each menu contains a QUIT option that immediately terminates the hpsadmin program The hpsadmin menus are organized as follows Main Menu Modify Driver Config HELP QUIT System Utilities Administration hps load hty load hps reset HELP QUIT Information Gathering hps log hpserrlog hty stat hpsver hps dump HELP QUIT HELP QUIT Diagnostic Utilities hps dloop hty check HELP QUIT HELP QUIT OPTIONS The following option may be selected C Allow only the Modify Driver Config option in the main menu This is used during driver installation FILES usr dtc bin menu gen Parallex menu engine usr lib dtc HELP FILES hlp Parallex menu help text SEE ALSO hps loa
29. or hty driver which is responsible for processing information for terminal sessions before the information is sent to the Parallex subsystem This driver may be configured to support asynchronous devices on one or more Parallex adapters Both of these device drivers are installed into the system kernel Refer to the appropriate chapter for your system for detailed installation and configuration information Utilities SYSTECH provides utilities for initializing monitoring diagnosing and troubleshooting your Parallex subsystem These powerful utilities are accessed through SYSTECH s hpsadmin menu program which also allows you to view or change the Parallex driver configuration There are two types of utilities e System utilities which are used for e Administration to manage the Parallex subsystem e Information gathering to monitor and gather statistical information e Diagnostics utilities which are used to test the operation of the Parallex subsystem For a discussion of the utilities refer to chapter 7 Documentation e Customer information e This user manual Packaged with your starter kit is important customer information including a warranty card that should be returned to SYSTECH The user manual is all you ll need to install and operate your Parallex serial communications subsystem Your Parallex Subsystem 11 dh A Service Precautions Refer all servicing to qualified service personnel 12 CAUTION El
30. our Parallex subsystem contains the distributed terminal communications DTC installation package which comprises the necessary device driver object code the Parallex utility manager hpsadmin the host utility programs the on line manual pages and the download images for the Parallex subsystem You ll use the SCO custom utility to install the entire runtime package The installation steps are 1 Log onto the system as root 2 SYSTECH recommends that you make a backup copy of the original kernel before continuing To make a copy of the kernel execute the following commands cd cp unix unix backup 3 Type custom to run the utility For more information on the custom ADM utility refer to your system administrator s reference manual 4 Select the Install option then press the enter or return key 5 Select the A new product option then press enter or return 6 Select the Entire Product option then press enter or return SCO Driver Installation 17 7 18 When prompted for the Distribution Floppy Volume 1 diskette insert the DTC Runtime Package for SCO diskette provided with your Parallex subsystem in the appropriate disk drive then press the enter or return key The system will take a minute or two to extract the necessary files After the system recognizes the DTC Runtime Package press the enter or return key again After the files are extracted from the diskette hpsadmin takes over as
31. pport representative 3 Reattach the host to Parallex cable and boot your system V Is the following message displayed on your console ahi start 0 Parallel port control register 0x37A not responding If yes STOP You specified the wrong I O address for the parallel port Check your hardware manual or configuration for the correct address then use hpsadmin to change the driver configuration and rebuild the kernel Y Did the Parallex adapter reset If no STOP You have one of the following problems e There is a controller at the I O address you specified but it is not the controller your Parallex subsystem is attached to Check your hardware manual or configuration for the correct address and then use hpsadmin to change the driver configuration and rebuild the kernel e The driver was not correctly installed Reinstall the driver 37 4 6 38 e You did not plug in the cable Check to ensure that each end of the cable is securely connected e The cable is bad Try a known working cable After resetting properly the Parallex subsystem should pass self test again then wait with the LED blinking a steady heartbeat pattern Y Is either of the following messages displayed on your console ahi I O error Reverse Receive failed SCS 20XX on parallel port base 0x378 ahi I O error Received invalid iolen value SCS 20XX on parallel port base 0x378 If yes STOP Your port is eithe
32. ption to verify the setting or change you entered After confirming the selection you ll be returned to the Terminal menu Repeat steps 3 4 and 5 for each hty device port to be enabled 20 SCO Driver Installation 7 After configuring the system for each hty device port you wish to enable press the escape key to exit the Create menu once again to exit the Terminal menu and a third time to exit the Accounts menu Then select the Quit option 8 The enable C command is used to enable individual ports for login The command causes the system to send a login prompt to the terminal connected to the hty device specified in the command For example enable hty01 would cause the system to send a login prompt to the terminal connected to dev hty01 Repeat this step for each port you wish to enable for login 9 Type init q SCO Driver Installation 21 Chapter 5 UnixWare Driver Installation NOTE Review the following information before you begin the installation process Some of the information you will be required to provide may require consulting with your system administrator You may wish to prepare a configuration worksheet containing the following information which will be requested during the installation the model number of the Parallex subsystem SCS model the parallel port address to use and the parallel port interrupt number to be used Installing the Driver Support Package The Driver Software Package DSP di
33. r set up wrong or is not capable of bi directional operation Note that in this con dition the Parallex subsystem will reset every time it finishes self test Verify that your host computer s parallel port can be enabled as bi directional and then ensure that it is set for bi directional operation You may need to enable bi directional mode through the system configuration or through a hardware switch or jumper V Is the following message displayed on your console ahi I O error PPS TERMINATE Failed Event 24 SCS 20XX on parallel port base 0x378 If yes STOP You most likely specified the wrong interrupt number for the parallel port Check your hardware setup and descriptions Note that in this condition the Parallex subsystem will reset every time it finishes self test Use hpsadmin to set up the correct interrupt in the driver configuration and rebuild the kernel f you have progressed to this point without error the console will display the appropriate message for your system e for SCO HPS AHI 0x0378 0x037B 7 HPS unit 0 e for UnixWare ahi 0 IRQ 7 I O ADDR 0x378 0x37B These messages indicate that the driver has found the Parallex subsystem If the message is not displayed go back and check for any of the previous error messages from the driver e for SCO examine the file usr adm messages e for UnixWare run crash and enter the command panic Next try the following commands in the order shown
34. rminated on at least one end with a DB 25 connector to PRINTER on the Parallex adapter Connect the free end to your parallel printer Pinouts for the Parallex subsystem s pass through printer port are defined in appendix A Placement Place the Parallex subsystem in a convenient location for your environment A stand is provided with each Parallex subsystem so that you may position the adapter vertically if desired The vertical configuration takes up the least amount of floor or desk space You can however use the Parallex subsystem without the stand by positioning the adapter horizontally on any available workspace To use the stand hold the adapter in a vertical position with the POWER connector at the bottom and the LED at the top Then match the molded line on the Parallex adapter to the molded groove in the cavity of the stand and slide the adapter fully onto the stand Connector and Cable Specifications SYSTECH uses a symmetrical RS 232 data terminal equipment DTE pinout on the RJ 45 connectors This eases the configuration of straight through and null modem cables Table 6 1 lists the pinouts of the RJ 45 ports used for RS 232 serial communications Figure 6 1 shows the configuration required for a straight through cable terminated with RJ 45 connectors Table 6 1 RS 232 RJ 45 Pinouts RJ 45 RS 232 Pin Number Name Direction Signal Function 1 DCD input Signals module that remote device is attached
35. s check dev hty n e The same device as that listed in etc inittab 41 e Run who r to get the run level of the system then verify that the run level matches the etc inittab entry where a getty would run Multi user run levels are system dependent but they are usually levels 2 and or 3 e Run the hty_check utility You can execute this utility manually or through hpsadmin Instead of the login prompt garbled text appears on the terminal e Check the terminal settings baud rate data stop bits parity etc for correctness You can log into the terminal but once a stop output usually S is set output will not resume with a start output command usually Q e Check the data and stop bit settings Other Problems Non Fatal Errors Sometimes error messages reported from the host resident Parallex device drivers and the Parallex adapter resident software are out of your control but are not considered fatal These errors will not cause e The Parallex subsystem to shutdown e User terminal sessions to stop e The Parallex adapter LED pattern to change For informational purposes SYSTECH recommends that you record an error of this type if it is reported to your system console Fatal Errors Fatal errors are those which are out of the user s control and which can cause the Parallex subsystem to shut down Under normal use it is unlikely that the user will encounter these types of errors Fatal error messages can
36. sary to execute it directly hps reset resets the Parallex subsystem hty load downloads the driver configuration to the driver and Parallex subsystem Parallex Utility Programs 31 e System information gathering utilities are used to monitor and gather statistical information These include u hps dump dumps Parallex subsystem memory to a host computer for SYSTECH problem analysis hps log displays statistics on system traffic for the Parallex subsystem hpserrlog displays a record of errors occurring on the Parallex subsystem hpsver displays Parallex subsystem software version information hty_stat displays terminal settings for ports on the Parallex subsystem e Diagnostic utilities are used to test the operation of the Parallex subsystem These include e hps_dloop a loopback test for Parallex subsystem memory e hty_check a terminal setup test program Using hpsadmin Hpsadmin SYSTECH s menu program serves a dual function It allows you to view and or modify the Parallex subsystem driver configuration and it provides an easy access to the Parallex utilities To run hpsadmin wait until your system prompt is displayed then enter hpsadmin The main menu will be displayed on the console screen From the main menu you can choose either to modify or view the driver configuration file to select one of the two main types of utilities system or diagnostic or to request help information The fol
37. se There are two standard options 5 and 7 e The type of parallel port There are two options PS 2 and Compaq Select PS 2 unless your host system is a Compaq NOTE The menus provide reset and help options Selecting reset resets the screen to the default values Selecting help displays help information d Press the escape key to return to the Driver Configuration menu Ensure that the configuration you established for the Parallex subsystem is correct by selecting the View option UnixWare Driver Installation e Exit the View menu by pressing the escape key f Press the escape key again to initiate the installation process g A message will tell you that the driver modules are being installed UNIX minor device numbers are assigned sequentially from 0 For example if your configuration is for an SCS 2008 the UNIX minor device numbers would be as shown in table 4 1 Note that port hty08 in the example is a printer port Parallex Adapter UNIX Minor On board dev hty entries Devices Channel 0 0 8 0 8 dev hty00 hty08 7 After the drivers are configured pkgadd will inform you that the kernel must be rebuilt for the changes to be effective You may rebuild the kernel manually with the UnixWare idbuild ADM utility or automatically with hpsadmin Refer to idbuild ADM in your UnixWare system administrator s reference manual for more information Exit the pkgadd program by selecting the Quit option NOTE
38. skettes provided with your Parallex subsystem contain the necessary components to install the Parallex subsystem s DIC package The DTC specific objects within the DSP consist of device driver object modules the Parallex utility manager hpsadmin host utility programs the on line manual pages and a Parallex subsystem download image The DTC package is installed by issuing the UNIX command pkgadd Installing the DTC Package Using pkgadd 1 2 Log onto the system as root SYSTECH recommends that you make a backup copy of the original kernel before continuing To make a copy of the kernel execute the following commands cd stand cp unix unix backup Insert the DTC Runtime Package for UnixWare diskette into the appropriate floppy drive To install the DTC package execute the following command followed by a carriage return note that N is the floppy unit number pkgadd d dev dsk 03ht After the DTC components are extracted from the diskette hpsadmin takes over as the driver installation interface An information screen DTC Subsystem SETUP appears first This screen identifies the information you ll be required to specify for the driver installation e Parallel port interrupt vector number and parallel port I O base address UnixWare Driver Installation 23 6 e Parallel port interface type e Parallex SCS model number Press the y yes key to continue Remove the DTC Runtime Package for UnixWare diskette
39. tem SYSTECH has designed a menu based interface program hpsadmin which enables you to e View or change the Parallex driver configuration e Call up and execute any of the Parallex utilities Specific information about how to use hpsadmin appears in the section titled Using hpsadmin later in this chapter NOTE hpsadmin was designed for use with several SYSTECH products the hps prefix refers to a generic family of products Overview of Parallex Utilities The Parallex subsystem software includes a suite of utility programs for use with the Parallex subsystem Two types of utilities system and diagnostic are provided The utilities are identified below a detailed explanation of each utility appears as an on line man manual page that will be loaded onto your system with the Parallex software NOTE The utilities listed below were designed for use with several SYSTECH products NOTE For UnixWare users to access the utilities easily your path must contain usr dtc bin e System utilities are divided into two categories those used for administration of the subsystem and those used to collect information about the subsystem e System administration utilities are used to perform a variety of functions to manage the operation of the Parallex subsystem These include hps load downloads the Terminal Control Software to the Parallex subsystem This program operates as a daemon and is started at boot time It is normally unneces
40. the driver installation interface An informational screen DTC Subsystem SETUP appears first This screen identifies the information you ll be required to specify for the driver installation e Parallel port interrupt vector number and parallel port I O base address e Parallel port interface type e Parallex SCS model number Press the y yes key to continue Remove the DTC Runtime Package for SCO diskette Driver Configuration To operate properly the driver must be configured to recognize the Parallex subsystem The hpsadmin utility allows you to view or modify the driver configuration if you change the configuration in any way During driver installation hpsadmin is initiated automatically however any time after the driver is installed you can run hpsadmin to change the existing configuration The configuration is downloaded to the driver during the boot process Any time you change the driver configuration you must reboot the system for the new configuration to take effect NOTE For movement through hpsadmin use the down arrow key to advance the up arrow key to back up within a menu the enter or return key on some systems to make a selection and the escape key to save any new values selected within a menu and return to the previous menu a From the Driver Configuration menu presented after the DTC Subsystem SETUP screen press 1 to indicate that you have one Parallex adapter connected to your host computer
41. tive printer driver De Installing the Parallex or Other Drivers If you choose to remove the Parallex driver or any others from your system follow the procedures outlined in the following sections If you re not planning to add another Disabling the Printer Driver 15 package immediately rebuild the kernel as described in the driver installation instructions for your particular driver then reboot your system De installing Other Drivers with SCO Installable driver packages for example the Parallex driver are removed using a different procedure than that described for native drivers such as the parallel printer driver To de install the Parallex driver package or any other installable driver package run the custom utility and specify the Remove option as described below 1 Log onto the system console as root 2 Type the command tom Select the Remove option Select the name of the package to be removed DTC for the Parallex driver package Select Entire Package for removal O go Custom will ask you to confirm your selection before removing the package Select Continue De Installing Other Drivers with UnixWare With the exception of native drivers such as the parallel printer driver installable driver packages including the Pabrallex driver can be removed from your UnixWare system Use the pkgrm package remove utility to remove an existing driver from your UnixWare system as shown below Enter the na
42. ystem to appear to the host computer as a single board multiplexer which handles up to 32 lines depending on the model of Parallex subsystem used The software includes character preprocessing which significantly lightens the terminal handling burden on the host operating system The Terminal Control Software is downloaded from the host after each hardware component has completed ts self test operations Internal Diagnostics SYSTECH provides a comprehensive set of power up and in service diagnostics for Parallex subsystems During initialization the Parallex subsystem checks its own hardware then conducts a handshaking session with the host computer to check the host to Parallex data paths In addition SYSTECH provides a program loader which permits you to quickly download the Terminal Control Software during system initialization 10 Your Parallex Subsystem In service diagnostics may be invoked by the host system at any time without disturbing on going terminal I O Loopback tests may run from the host to the Parallex subsystem Device Drivers SYSTECH provides a run time version of SCO UNIX and SVR4 UnixWare device drivers Two types of drivers are supplied in this package both of which are required for proper operation of the Parallex subsystem e The Parallex adapter rhp or dtc driver which is responsible for passing packets of information to and receiving packets from the Parallex subsystem e The terminal device
Download Pdf Manuals
Related Search
Related Contents
SmartMetals INT.1055 flat panel floorstand Manual - LPT Home Page - HP LaserJet and Lexmark Parts カタログ Agilent Technologies E1470A Switch User Manual Husqvarna 371K Brush Cutter User Manual Sin título-2 - Bienvenidos a Würth Uruguay 取扱説明書 2 3 5 1 6 4 こちら KitchenAid KECD805E User's Manual Copyright © All rights reserved.