FX3U-4AD-TC-ADP USER`S MANUAL

image

Contents

1. External power i supply wiring 24 V DC 12 Grounding Ground resistance 100 Q or less LO L ch represents the channel number When using the Type J thermocouple short circuit the Type J terminals and turn the special auxiliary relay Type K J mode changeover ON For details of auxiliary relays refer to the following manual FX3s FX3G FX3GC FX3u FX3uc Series User s Manual Analog Control Edition 2 24 V DC service power supply of the FX3S FX3G FX3U Series PLC can also be used 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 100 Q or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the respective PLC User s manual Hardware Edition Other Other PLC equipment Q Q Q Independent grounding Common grounding Not allowed Best condition Shared grounding Good condition e The grounding wire size should be AWG 22 20 0 3 0 5 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specifications STARTUP AND MAINTENANCE PRECAUTIONS NCAUTION e Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representa
2. Strand wire single wire Stick terminal with insulating sleeve Contact area Crimp area Insulation sleeve 2 6mm 0 1 3 2 Power Supply Wiring For the power supply wiring refer to the following manual FX3s FX3G FX3Gc FX3u FX3uc Series User s Manual Analog Control Edition 3 3 Selection of thermocouple For the terminal configuration refer to Section 1 2 Precautions on thermocouple wiring e Thermocouple type There are 2 types of thermocouples Type K and Type J Select the desired type However be sure to connect the same type of thermocouple to all the channels Use insulated thermocouple types e Compensating lead wire To connect the thermocouple use one of the right types of compensating lead wires The compensating lead Type J wire indicates the temperature value of approximately 0 12 C higher than that of the wire resistor 10 Q Temperature value should be used in consideration of this point If the compensating lead wire is very long the wire may be easily affected by noise etc It is therefore recommended that the length of the compensating lead wire should be 100 m 328 1 or less Example of thermocouple wiring Using Type J eee L___ J type Thermocouple Wiring yP Teea Compensating lead Thermocouple _wire Shielded _ 3kQ Thermocouple Type of compensating lead wire Type K KX KCA KCB KCC JX TC ADP
3. when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JY997D14801K MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEGIP JAPANESE ENGLISH FX3u 4AD TC ADP USER S MANUAL F X 3u Manual Number JY997D14801 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Effective April 2015 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories and ZXCAUTION A Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury Indicates that incorrect handli
4. Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed Make sure to properly wire the terminal block in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual of the PLC main unit Tightening torque should follow the specifications in the manual of the PLC main unit 3 1 Applicable cable and terminal tightening torque 3 1 1 Type terminal block European type 1 Wire size The power supply wiring and the Type K J changeover input wiring should use 22 20 AWG wire Thermocouple wiring should use the compensating lead wire suitable for the type of thermocouple For details of compensating lead wire Refer to Section 3 3 2 Applicable cable Wire size Single wire 0 3 mm2 to 0 5 mm2 AWG22 to 20 2 pieces of 0 3 mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve lt Reference gt Manufacturer Caulking tool CRIMPFOX 6 Phoenix Contact Co Ltd or CRIMPFOX 6T F 2 Al 0 5 8WH 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6
5. Fol T off S 1 OWLS O aE l Of l a Aer 1 OB lono A oL ala Ko i e c oO Solaz ol z J oO o OWLS E amp E 4 off OLI 4 off Special adapter connector cover is removed Weight Approx 0 1 kg 0 22 Ibs 1 DIN rail mounting groove DIN rail DIN46277 2 Name plate 3 Special adapter slide lock Used to connect additional special adapters onto the left side of this special adapter 4 Special adapters connector cover Remove this cover to connect additional special adapters to the left side 5 Direct mounting hole 2 holes of 64 5 0 18 mounting screw M4 screw Not used when connecting to FX3GC FX3UC Series PLC 6 POWER LED green Lit while 24 V DC power is supplied properly to terminals 24 and 24 7 Terminal block European type Connect thermocouple sensor input Type K or J changeover input and 24 V DC power supply 8 Special adapter connector Used to connect this special adapter to PLC main unit or special adapter 9 DIN rail mounting hook 10 Special adapter fixing hook 11 Special adapter connector Used to connect communication or analog special adapters to the left side of the TC ADP 2 Installation For installation uninstallation details refer to the respective PLC User s manual Hardware Edition INSTALLATION PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wi
6. PRECAUTIONS CAUTION e When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions e Make sure to observe the following precautions in order to prevent malfunctions under the influence of noise 1 Do not bundle the power line or shield of the analog input output cable together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit high voltage line or load line 2 Ground the shield of the analog input output cable at one point on the signal receiving side However do not use common grounding with heavy electrical systems e Make sure to properly wire to the terminal block European type in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size
7. left side of the TC ADP 2 Installation For installation uninstallation details refer to the respective PLC User s manual Hardware Edition INSTALLATION PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS CAUTION e Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect special adapter securely to their designated connectors Loose connections may cause malfunctions 2 1 Connection to the PLC This section describes the connection method to the PLC FX3U Series PLC is used for the following example For installation method to other PLCs refer to the respective
8. other high speed I O special adapters 3 Wiring WIRING PRECAUTIONS WARN ING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product WIRING PRECAUTIONS CAUTION When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Make sure to observe the following precautions in order to prevent malfunctions under the influence of noise 1 Do not bundle the power line or shield of the analog input output cable together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit high voltage line or load line 2 Ground the shield of the analog input output cable at one point on the signal receiving side However do not use common grounding with heavy electrical systems Make sure to properly wire to the terminal block European type in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the man
9. used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN
10. JY997D14801K MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEGIP JAPANESE ENGLISH FX3u 4AD TC ADP USER S MANUAL F X 3u Manual Number JY997D14801 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Effective April 2015 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories ZAWARNING and ZXCAUTION Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by CAUTION may also cause severe injury It is important to follow all precautions for personal safety Associa
11. O wiring installation and maintenance FX3UC Series User s Manual Hardware Edition Explains FX3UC Series PLC specifications for I O wiring installation and maintenance How to obtain manuals For product manuals or documents consult with the Mitsubishi Electric dealer from who you purchased your product Applicable standards FX3U 4AD TC ADP units made in June 2005 or later comply with the EC Directive EMC Directive and UL standards UL cUL Further information can be found in the following manual FX3s Series Hardware Manual Manual No JY997D48301 FX3G Series Hardware Manual Manual No JY997D46001 FX3Gc Series Hardware Manual Manual No JY997D45201 FX3u Series Hardware Manual Manual No JY997D18801 FX3uc D DS DSS Series Hardware Manual Manual No JY997D28601 FX3uUc 32MT LT 2 Hardware Manual Manual No JY997D31601 Regarding the standards that relate to the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Attention e This product is designed for use in industrial applications Note e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best per formance from
12. PLC User s manual Hardware Edition Procedure 1 Turn off the power Disconnect all the cables connected to the PLC main unit and special adapter and demount the main unit and special adapter mounted on DIN rail or mounted directly using screws 2 Install an expansion board to the main unit For the expansion board installation procedure refer to the following manual FX3u Series User s Manual Hardware Edition 3 Remove the special adapter connector cover on the expansion board fig A When connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated 4 Slide the special adapter slide lock fig B of the main unit When connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 5 Connect the special adapter fig C to the main unit as shown on the right Slide back the special adapter slide lock fig B of the main unit to fix the special adapter fig C 6 lt Connection precautions Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination Do not connect a high speed I O special adapter on the left side of an special adapters other than
13. a will be updated at every scan time of the PLC time e FX3S FX3G FX3GC Series PLC 250 us The data will be updated at every scan time of the PLC l H f 1D n 12 fs 1O 12 Ve i 1 1832 F Input characteristics ee EEE Ae H IL 1O 12 Ra H e The photocoupler is adopted to insulate the analog input area from the PLC insulation e The DC DC converter is adopted to insulate the power method supply line from the analog input area e Achannels are not insulated from each other Occupied 0 point This number is not related to the maximum number of points input output points of the PLC This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system
14. cates the temperature value of approximately 0 12 C higher than that of the wire resistor 10 Q Temperature value should be used in consideration of this point If the compensating lead wire is very long the wire may be easily affected by noise etc It is therefore recommended that the length of the compensating lead wire should be 100 m 328 1 or less Example of thermocouple wiring Using Type J eons t Thermocouple Wiring spe Compensating lead wire Shielded Thermocouple Type of compensating lead wire Type K KX KCA KCB KCC JX Terminal block TC ADP Thermocouple ae supply wiring A 24 avos ae ewes 4 Grounding Ground resistance 100 Q or less LO LO ch represents the channel number When using the Type J thermocouple short circuit the Type J terminals and turn the special auxiliary relay Type K J mode changeover ON For details of auxiliary relays refer to the following manual FX3s FX3G FX3Gc FX3u FX3uc Series User s Manual Analog Control Edition 2 24V DC service power supply of the FX3S FX3G FX3U Series PLC can also be used 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 100 Q or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the foll
15. e users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC protection is provided then users may experience temporary loss or accuracy between 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed for the users complete control system users should expect accuracy as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good cable shielding should be used When terminating the shield at Earth ensure that no earth loops are accidentally created e When reading analog values EMC accuracy can be improved out by averaging the readings This can be achieved either through functions on the analog special adapters or through a users program 1 Outline FX3U 4AD TC ADP hereinafter called TC ADP is an analog special adapter for measuring temperature via four channels of connected Type K or Type J thermocouple thermometer 1 1 Incorporated Items Verify that the following product and items are included in the package FX3U 4AD TC ADP K J type thermocouple thermometer input special adapter Product Accessories User s manual This manual 1 2 External Dimensions Part Names and Terminal Layout 10 5
16. following product and items are included in the package FX3U 4AD TC ADP K J type thermocouple thermometer input special adapter Product Accessories User s manual This manual 1 2 External Dimensions Part Names and Terminal Layout 10 5 oft E 4 o0 S OW a aB Of l a Aer 1 OB lono A oL ala Ko OHS S aos J Ho ala s c y Of z J oO o OL E 4 off OLI of Special adapter connector cover is removed Weight Approx 0 1 kg 0 22 Ibs 1 DIN rail mounting groove DIN rail DIN46277 2 Name plate 3 Special adapter slide lock Used to connect additional special adapters onto the left side of this special adapter 4 Special adapters connector cover Remove this cover to connect additional special adapters to the left side 5 Direct mounting hole 2 holes of 64 5 0 18 mounting screw M4 screw Not used when connecting to FX3GC FX3UC Series PLC 6 POWER LED green Lit while 24 V DC power is supplied properly to terminals 24 and 24 7 Terminal block European type Connect thermocouple sensor input Type K or J changeover input and 24 V DC power supply 8 Special adapter connector Used to connect this special adapter to PLC main unit or special adapter 9 DIN rail mounting hook 10 Special adapter fixing hook 11 Special adapter connector Used to connect communication or analog special adapters to the
17. from who you purchased your product Applicable standards FX3U 4AD TC ADP units made in June 2005 or later comply with the EC Directive EMC Directive and UL standards UL cUL Further information can be found in the following manual FX3s Series Hardware Manual Manual No JY997D48301 FX3G Series Hardware Manual Manual No JY997D46001 FX3Gc Series Hardware Manual Manual No JY997D45201 FX3u Series Hardware Manual Manual No JY997D18801 FX3uc D DS DSS Series Hardware Manual Manual No JY997D28601 FX3uc 32MT LT 2 Hardware Manual Manual No JY997D31601 Regarding the standards that relate to the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Attention e This product is designed for use in industrial applications Note e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best per formance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators thes
18. ng may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by CAUTION may also cause severe injury It is important to follow all precautions for personal safety Associated Manuals Manual name Description JY997D16701 MODEL CODE 09R619 Describes specifications for analog control and programming method for FX3S FX3G FX3GC FX3U FX3UC Series PLC FX3S FX3G FX3GC F X3U FX3UC Series User s Manual Analog Control Edition FX3S FX3G FX3GC F X3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition JY997D16601 MODEL CODE 09R517 Describes PLC programming for basic applied instructions and devices FX3S Series JY997D48601 Explains FX3S Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R535 installation and maintenance FX3G Series JY997D31301 Explains FX3G Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R521 installation and maintenance JY997D45401 MODEL CODE 09R533 JY997D16501 MODEL CODE 09R516 JY997D28701 MODEL CODE 09R519 FX3GC Series User s Manual Hardware Edition Explains FX3GC Series PLC specifications for I O wiring installation and maintenance FX3U Series User s Manual Hardware Edition Explains FX3U Series PLC specifications for I
19. nnecting it An alternative connection is to use a ferrule with insulating sleeve lt Reference gt Manufacturer Caulking tool CRIMPFOX 6 i or CRIMPFOX 6T F 2 Al 0 5 8WH 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 Strand wire single wire Phoenix Contact Co Ltd Stick terminal with insulating sleeve Insulation sleeve Contact area Crimp area 0 35 _ 2 6mm 0 1 When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25 Nem Do not tighten terminal screws exceeding the specified torque Failure to do so may cause equipment failures or malfunctions 3 2 Power Supply Wiring For the power supply wiring refer to the following manual FX3s FX3G FX3Gc FX3uU FX3uc Series User s Manual Analog Control Edition 3 3 Selection of thermocouple For the terminal configuration refer to Section 1 2 Precautions on thermocouple wiring e Thermocouple type There are 2 types of thermocouples Type K and Type J Select the desired type However be sure to connect the same type of thermocouple to all the channels Use insulated thermocouple types e Compensating lead wire To connect the thermocouple use one of the right types of compensating lead wires The compensating lead Type J wire indi
20. oard to the main unit For the expansion board installation procedure refer to the following manual FX3u Series User s Manual Hardware Edition 3 Remove the special adapter connector cover on the expansion board fig A When connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated 4 Slide the special adapter slide lock fig B of the main unit When connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 5 Connect the special adapter fig C to the main unit as shown on the right Slide back the special adapter slide lock fig B of the main unit to fix the special adapter fig C 6 lt Connection precautions Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination Do not connect a high speed I O special adapter on the left side of an special adapters other than other high speed I O special adapters 3 Wiring WIRING PRECAUTIONS WARN ING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product WIRING
21. owing figure For details refer to the respective PLC User s manual Hardware Edition Other Other PLC lequipment C Independent grounding Common grounding Not allowed Best condition Shared grounding Good condition e The grounding wire size should be AWG 22 20 0 3 0 5 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specifications STARTUP AND MAINTENANCE PRECAUTIONS Z CAUTION e Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representative e Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORTATION AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product 4 1 Applicable PLC Model name FX3S Series PLC FX3G Series PLC _ Ver 1 00 or later from first production Applicability Ver 1 00 or later from first production FX3GC Series PLC Ver 1 40 or later from first production FX3U Series PLC Ver 2 20 or later from first produc
22. rial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25 Nem Do not tighten terminal screws exceeding the specified torque Failure to do so may cause equipment failures or malfunctions
23. ring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS CAUTION e Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect special adapter securely to their designated connectors Loose connections may cause malfunctions 2 1 Connection to the PLC This section describes the connection method to the PLC FX3U Series PLC is used for the following example For installation method to other PLCs refer to the respective PLC User s manual Hardware Edition Procedure 1 Turn off the power Disconnect all the cables connected to the PLC main unit and special adapter and demount the main unit and special adapter mounted on DIN rail or mounted directly using screws 2 Install an expansion b
24. ted Manuals Manual name Description JY997D16701 MODEL CODE 09R619 Describes specifications for analog control and programming method for FX3S FX3G FX3GC FX3U FX3UC Series PLC FX3S FX3G F X3GC F X3U FX3UC Series User s Manual Analog Control Edition FX3S FX3G FX3GC F X3U FX3UC Series JY997D16601 Describes PLC programming Programming Manual MODEL CODE for basic applied instructions Basic amp Applied Instruction 09R517 and devices Edition FX3S Series JY997D48601 Explains FX3S Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R535 installation and maintenance FX3G Series JY997D31301 Explains FX3G Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R521 installation and maintenance JY997D45401 MODEL CODE 09R533 JY997D16501 MODEL CODE FX3GC Series User s Manual Hardware Edition Explains FX3GC Series PLC specifications for I O wiring installation and maintenance FX3U Series User s Manual Hardware Edition Explains FX3U Series PLC specifications for I O wiring installation and maintenance 09R516 JY997D28701 MODEL CODE 09R519 FX3UC Series User s Manual Hardware Edition Explains FX3UC Series PLC specifications for I O wiring installation and maintenance How to obtain manuals For product manuals or documents consult with the Mitsubishi Electric dealer
25. tion Ver 1 30 or later from the production manufactured in August FX3UC Series PLC 2004 with SER No 48 The version number can be checked by monitoring D8001 D8101 as the last three digits indicate it 4 2 General Specifications Items other than the following are equivalent to the those of the PLC main unit For general specifications refer to the respective PLC User s manual Hardware Edition Item Dielectric withstand Specification voltage Between all terminals and 500 V AC for one minute ground terminal of PLC 5 MQ or more by 500 V DCJ main unit megger 4 3 Power Supply Specifications Insulation resistance Item Specification A D conversion 24 V DC 20 15 45 mA for 24 V DC circuit driving power Connect a 24 V DC power supply to the terminal block 5V DC 15 mA 5 V DC power is supplied from the internal power supply of main unit Interface driving power 4 4 Performance Specifications Specifications Item Centigrade C Fahrenheit F Thermocouple type K or J inputelgnal JIS C 1602 1995 Rated Type K 100 C to 1000 C Type K 148 F to 1832 F temperature range Type J 100 C to 600 C Type J 148 F to 1112 F Type K 1000 to 10000 TypeK 1480 to 18320 TypeJ 1000 to 6000 TypeJ 1480 to 11120 Digital output Resolution Total accuracy 0 5 full scale 1 C e FX3U FX3UC Series PLC 200 us A D conversion The dat
26. tion resistance Item Specification A D conversion 24 V DC 20 15 45 mA for 24 V DC circuit driving power Connect a 24 V DC power supply to the terminal block 5V DC 15 mA 5 V DC power is supplied from the internal power supply of main unit Interface driving power 4 4 Performance Specifications Specifications Item Centigrade C Fahrenheit F 5 Thermocouple type K or J input signal JIS C 1602 1995 Rated Type K 100 C to 1000 C Type K 148 F to 1832 F temperature range Type J 100 C to 600 C Type J 148 F to 1112 F Type K 1000 to 10000 TypeK 1480 to 18320 Type J 1000 to 6000 Type J 1480 to 11120 Digital output Resolution Total accuracy 0 5 full scale 1 C e FX3U FX3UC Series PLC 200 us A D conversion The data will be updated at every scan time of the PLC time e FX3S FX3G FX3GC Series PLC 250 us The data will be updated at every scan time of the PLC 1010 C 1850 F Input characteristics 1 Li l 1 1 1 1 1 1 1 1 i i i N l E1130 F e The photocoupler is adopted to insulate the analog input area from the PLC Insulation e The DC DC converter is adopted to insulate the power method f supply line from the analog input area e A channels are not insulated from each other Occupied 0 point This number is not related to the maximum number of points input output points of the PLC This manual confers no indust
27. tive e Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORTATION AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product 4 1 Applicable PLC Model name FX3S Series PLC FX3G Series PLC Ver 1 00 or later from first production Applicability Ver 1 00 or later from first production FX3GC Series PLC Ver 1 40 or later from first production FX3U Series PLC Ver 2 20 or later from first production Ver 1 30 or later from the production manufactured in August FX3UC Series PLC 2004 with SER No 48 The version number can be checked by monitoring D8001 D8101 as the last three digits indicate it 4 2 General Specifications Items other than the following are equivalent to the those of the PLC main unit For general specifications refer to the respective PLC User s manual Hardware Edition Item Dielectric withstand Specification voltage Between all terminals and 500 V AC for one minute ground terminal of PLC 5 MQ or more by 500 V DCJ main unit megger 4 3 Power Supply Specifications Insula
28. ual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed Make sure to properly wire the terminal block in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual of the PLC main unit Tightening torque should follow the specifications in the manual of the PLC main unit 3 1 Applicable cable and terminal tightening torque 3 1 1 Type terminal block European type 1 Wire size The power supply wiring and the Type K J changeover input wiring should use 22 20 AWG wire Thermocouple wiring should use the compensating lead wire suitable for the type of thermocouple For details of compensating lead wire Refer to Section 3 3 2 Applicable cable Wire size Single wire 0 3 mm2 to 0 5 mm2 AWG22 to 20 2 pieces of 0 3 mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before co
29. what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC protection is provided then users may experience temporary loss or accuracy between 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed for the users complete control system users should expect accuracy as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good cable shielding should be used When terminating the shield at Earth ensure that no earth loops are accidentally created e When reading analog values EMC accuracy can be improved out by averaging the readings This can be achieved either through functions on the analog special adapters or through a users program 1 Outline FX3U 4AD TC ADP hereinafter called TC ADP is an analog special adapter for measuring temperature via four channels of connected Type K or Type J thermocouple thermometer 1 1 Incorporated Items Verify that the

Download Pdf Manuals

image

Related Search

Related Contents

0MAN207 Uso Manutenzione Zero  ft-samosa-r  SoundTouch™ Portable  Télécharger ce fichier - l`Ecole de Musique de Bois  Reductores de la serie 7: R..7, F..7, K..7, S..7 - SEW  HQ Power EXPLIO I  DUO – shampooing + lotion en vapo + peigne – Cheveux protégés  Scarica libretto  Manual for CYPRUS (V1.0) (ATOM Dual Core Model)  Originalbetriebsanleitung MODULARES DURCHFLUSSZÄHLER  