User Manual - Sensortronic Scales

image

Contents

1. Menu Description F01 Setting backlight F02 Change the password F03 Setting lock of print key F04 Setting communication error message display F05 Setting auto save data at printing F06 Setting number of using PAD F11 Setting auto print F12 Setting line feed F13 Setting time F01 Setting backlight Key Function Display Value Description Other Key 0 3 key E Aways oi F01 1 At porra SET Save and exit the 2 At changing weight set mode 3 Always on F02 Change password Notice Initial password is 1234 in factory If PASS 1 is different from PASS 2 RW 2201B display error message Err 31 come back input mode of PASS1 Key Function Display Value Description To do not change pass Select 0 or 1 F02 Ol cd SET centena 1 To change password set mode F02 1 To change password Key PASS Display 0 SET o pas Input 4 number of password Good PASS 1 SET Input new password ___0 PASS 2 SET 0 Retry input new password F03 Setting lock of print key 14 Key Function Display Value Description Key SelectO 1 1 Use of lock F03 SET Exit set mode 0 Don t use You must check F02 before this mode F04 Display comm Error message Key Function Display Value Description Key SelectO 1 1 Don t use F04 SET Exit set mode 0 Display comm Error
2. F05 Auto save setting Key Function Display Value Description Key SelectO 1 1 Auto save at print SET ar set rop 0 Manual save F06 Setting number of pad Key Function Display Value Description Key SelectO 2 0 Use 2 PAD S E Tlexttheset F06 1 Use 1 PAD Number 1 s E r mode 2 Use 1 PAD Number 2 Notice PAD number is written on spec plate F11 Auto print Key Function Display Value Description Key SelectO 1 0 Don t use this function F11 ser Move the 1 Only status of stable next mode Notice If you select 1 of F11 this function is operated when the weight is over 1 max capacity 15 F12 Line feed Key Function Display Value Description Key Select 0 1 5 0 O line feed Move the F12 J J SET next mode 5 5 line feed Format Total Format 2006 11 24 14 32 54 TOTAL PRINT Truck No 1234 Truck No 1234 a AXLE 1 TOTAL AXLE 2 WEIGHT1 12056 kg TOTAL 4234kg WEIGHT2 10150 kg AXLE1 TOTAL 22206 kg _ AXLE 2 WEIGHT1 2056 kg WEIGHT2 4150 kg AXLE2 TOTAL 6206 kg F13 Setting time Key Function Display Value Description Key Select Oor1 F13 06 09 18 Input date SET End of set 10 30 54 Input time mode Notice If date input is done it will be change mode of input time
3. 16 7 How to measure vehicle See the below picture As you shown you can weigh the vehicle four time 1 If vehicle is on the PAD press print key because save the data and print data 2 If weighing is done you can ready next weighing Also if vehicle is on the PAD press print key The reason is same 3 Repeat 2 times 4 Gross weight of vehicle If weighing is all done press sum key because RW 2201B print gross data with 4 axel weight data Sort 1 step 2 step 3 step 4step 1 without dummy a E 5 2 PLATE B A X E 2 use dummy Ea mom L 2 PLATE 2 EM i QE a DUMMY PLATE a ig agi 3 A 1 use dummy DAEMEN omu Ltd x 2PLATE Hon Ooo oo i E 12 DUMMY HE mee Es i So 4 A 1 use dummy i omm m o x 2PLATE Eu Coma ooo uru E 12 DUMMY n o Gees TENS L Notice Even measuring by Dummy plate error of the actual weight can happen The error range is 3 from the Maximum capacity 17 8 Method of using RW 15B Using POWER ON OFF 1 POWER ON Press power S W for 2 sec 2 POWER OFF Press power S W POWER LAMP 1 LAMP OFF This is status of power off 2 LAMPON This is status of power on 3 LAMP blinking RW 15B is needed for charging notice As you shown side picture raised antenna help communication n far more than lay 18 9 How to save data Method 1 1 If wheel of vehicle on pad press save key 1 SAVE is di
4. Internal battery charger With Backlight O Internal Printer 3 Technical Specification RW 2201B Digital amp Display Display LCD 6 digit Sign Character size 24 mm height Display under zero minus display Display status ZERO STABLE UNIT kg Power AC 220 V 50 60Hz Operation temperature 10 C C 40 C C Wireless communication Blue tooth Composition RW 2201B RW 15B 2sets Product weight About 10 6kg Using time About 48 hours Charging time About 24 hours RW 15B Digital amp Display A D Speed 10 times second Power consumption about 0 5 W About 27kg except Ramp Ramp Weight 10kg ne At barrier place Opensite about 50M about 30M Communication distance Notice Communication distance will be changed by circumstance 4 Front pannel 3 Bluetooth POWER CHARGE Display Lamp Display Brief Description Stable lamp A Display this lamp at stable DONG Display this lamp at zero SU IM Display this lamp at sum mode o Percent lamp Display capacity of battery Display the status of PAD1 comm Display the status of PAD2 comm Display the weight of PAD1 Eo Low battery lamp Low battery lamp of RW 2201B LO Low battery lamp Low battery lamp of RW 15B Red lamp on Power lamp of printer Display the power on of printer pr
5. precautions A Warning When any damage or defect Insert plug firmly to wall outlet to Avoid placing the scale near occurs contact your CAS prevent electric shock heather or in direct sunlight authorized dealer immediately for proper repair Do not pull the plug by its cord To prevent from fire occurring To reduce electric shock or when unplugging Damaged Do not place or use the scale incorrect reading Do not spill cord could cause electric shock near flammable or corrosive water on the scale or place it in gas humid condition istent and accurate g maintain periodical check by your CAS authorized dealer Place the scale on firm and temperature consistent environment Avoid sudden shock to the scale Attach the rubber pad to the Internal mechanism could by bottom of the indicator damaged Elimination is possible Keep the scale away from the electromagnetic generation devices This may interfere with accurate reading Our Dealers CAS feels that each of its valued customers should get the best service available Whether it s the initial installation of our product maintenance repair work or simply answering questions about our products CAS Corporation and all of its Authorized Dealers are highly trained to assist you with any need regarding CAS products 2 Feature amp Mainfunction Feature Simple amp Light amp Portable O Easy Control O Internal battery
6. INDUSTRIAL WEIGHING SOLUTION RW 2201B Vehicle Weighing Scale Eh SA o o o D o w N ra o 3 TIVANVW S YSNMO Table of Contents 1 Introduction yissasvaniinasscanedanwussinntbesnnnnasane 5 2 Feature amp Main function 6 3 Technical Specification 6 4 Front Panel sicsicicsasssssenassacsntatocssanaaianess 8 5 TESE MOUE ansis anistia dida dai 11 6 Setting mode 13 7 How to measure vehicle 17 8 Method of using RW 15B 18 9 How to save data 20 10 Change roll of print 22 11 Error Message 23 1 Introduction Thank you for purchasing the CAS RW 2201B Series weighing indicator We have designed this equipment with many advanced features high quality construction and user friendly menu driven programming We are confident that you will find the CAS RW 2201B Series will meet all of your most demanding needs CAS indicator is shaped firmly and delicately designed to coincide with the special requirements of several industrial fields and includes many functions and various external interfaces Also it contains help display functions to be used easily Before using RW 2201B It is recommended to read this manual carefully and to apply the function application fully Precautions Observe the following safety
7. inter Green lamp on printer Self Test lamp of printer Display the ok or not ok of printer m Key Board ZERO Short Used to remove small vibration PAD Short Check the weight of each PAD Long Power off the all PAD Display OFF PRINT Short Used to print and sum weight Long Used to lock print To print input the pre setting password in F02 Notice Check first the setting mode before use this function FO3 gt 1 SUM Short Print all PAD weight of one vehicle Notice It can not print weight of all vehicle one day FIND Short Find saved data Notice Yon can print data of saved data TRUCK No Short To input vehicle number 4 digit SAVE Short To save the weight of PAD Max 10 vehicle Max 4 PAD weight of one vehicle Long To move next mode Notice If you press this key very often it will be saved data every time at other memory SET Short To go next mode or to save data Long To enter SET mode CLR Short To erase data Long To enter TEST mode 10 5 TEST MODE o How to enter TEST mode Turn on Power while press CLR key to enter test mode You will see massage conect Press SET key and then move to test menu o TEST menu TEST1 TEST6 TEST 1 Key test TEST 2 Battery test of RW 2201B TEST 3 Load cell test of PAD1 TEST 4 Load cell test of PAD2 TEST 5 Clock test TEST 6 P
8. ommunication Too far or many barrier Bout t1 out PAD1 t2 out PAD 2 Get close or remove barrier Check the pad power Err2 1 A D value is wrong En22 Err2 1 PAD 1 Err2 2 PAD 2 Tee Eee Check A D value ee Clear on the pad Er 11 Over the initial zero range ae Be aaa 6 Em 12 Err 11 PAD 1 Err12 PAD 2 Initial zero range is within 20 of Max weight Er 30 Entered password exceed 4 Input only 4 number numbers E31 Entered password is different from old Enter new password again password Err 50 Internal memory is erased Call your CAS dealer BT Em Fail to communication Retry communication This may damage load cell OUER1 Over the max weight of PAD1 You must reduce the weight under the max capacity This may damage load cell OUER2 Over the max weight of PAD2 You must reduce the weight under the max capacity batt Low battery of RW 2201B You must recharge the RW 2201B MEMO 22 MEMO 23 e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e r E O S E E r E E E ooo O ee RW 2201B Vehicle Weighing Scale CAS CAS BLDG 440 1 SUNGNAE DONG GANGDONG GU SEOUL KOREA TEL_ 82 2 2225 3500 FAX_ 82 2 475 4668 www globalcas com Specifications are subject to change for improvement without prior notice 9007 RWB 0033 0 2008 05
9. rint test TEST 1 Key test Key Function Display Description SET Move to TEST2 tESt 1 This is status of TEST 1 fa Operate test 1 Press key display value of key code key 1 2 8 4 6 18 7 8 2 0 CLR SET code 1 2 3 4 5 6 7 8 9 0 A b TEST 2 Battery TEST of RW 2201B Key Function Display Description SET Move to TEST3 tESt 2 This is status of TEST 2 6 00 Battery value of RW 2201B 11 TEST 3 Load Cell TEST of PAD1 Key Function Display Description SET Move to TEST4 tESt 3 This is status of TEST 3 24750 AD value of PAD1 TEST 4 Load Cell TEST of PAD2 Key Function Display Description SET Move to TEST5 tESt 4 This is status of TEST 4 23564 AD value of PAD2 TEST 5 Clock test Key Function Display Description tESt 5 This is status of TEST 5 PER 06 11 09 dAtE Display d setting or TEST6 Sus tE Display date 12 02 32 tIME Display time TEST 6 Printer test Key Function Display Description SET Move to weighing tESt 6 This is status of TEST 6 mode 600d Operate printer test Notice Output of print is below TEST OK 6 SET MODE o How to enter SET mode Turn on Power while press SET key or press long SET keyin weighing mode o SET Mode menu
10. splay This means wheel weight save done 2 Repeat the procedure 4times 1 vehicle 3 If you done press save key long Then It will show END message This procedure is for save data The result is saved weight of one vehicle If you see the FULL message memory is full It has memory of 10 vehicle Method 2 If you set 1 of FOS auto save function is used Auto save function is saved at print It is done at Total print Notice It is saved 4 axel weight data per vehicle If exceed 4 axel weight data will overwrite old data Search the saved data 1 Press FIND key Then it will be show 0 XXXX First number means order of saving and second number means number of vehicle 2 Press 2 key or 8 key It will be show save vehicle number 3 If you find what you want vehicle number press print key 4 If you delete data press CLR All saved data is erased 19 10 Change printer roll Insert roll Print Line Feed Key As you show above picture press line feed key after insert roll Then the paper is passing through cartridge Press line feed key again Then the paper is stop This is done See above the picture It is picture of removed cartridge If letter is not clear you must change cartridge Method of change is very simple Hold on the cartridge and pull up 20 11 Error message amp Trouble shooting 21 No Reason Trouble shooting ti out Fail to c