1. BRASSELER USA DENTAL INSTRU MENTATION High Speed Air Turbine Handpiece BRASSELER MINI Please read this Operation Manual carefully before use and file for future reference Handpiece should not be used with friction grip burs exceeding 18 5 mm in length l q 5 z lt pa O lt va LLI A O N CAUTION When operating the handpiece always consider the safety of the patient The handpiece is designed for dental clinical use Do not exceed maximum bur length of 18 55mm Check for vibration noise and overheating outside the patient s oral cavity before use If any abnormalities are found stop using and immediately contact Brasseler USA Should the handpiece function abnormally cease operation immediately and return the handpiece to Brasseler USA for repair Depressing the Push Button while the handpiece is in rotation will result in OVERHEATING of the handpiece head Special caution must be exercised during use to keep cheek tissue AWAY from the Push Button of the handpiece Contact with cheek tissue may cause the Push Button to depress and injury to the patient may occur Do not exceed the recommended air pressure as bur breakage or wear may occur if air pressure is exceeded Do not allow any impact on to the handpiece Do not drop the handpiece Refer to the coupling manual before connecting it to the handpiece tubing Do not attempt to disassemble the handpiece or tamper with th
2. Ring might remain in the Head when removing the Turbine If the O Ring remains the new Turbine can not be inserted properly Use only Brasseler USA genuine turbines If you use other Turbine specification may not be satisfied and void the warranty e The head cap screw thread is very fine To prevent damage to the thread always first tighten the handpiece head cap using fingers then secure with the head cap wrench Make sure that the O ring Fig 10 is correctly located on the cartridge 12 Replacing the O Rings Replace the O Rings if water is present in the exhaust air line This is an indication of possible water leakage within the coupling ALWAYS change the complete set of O Rings Loosen and Remove the Taper Ring at the rear of the handpiece Fig I I 2 Gently remove each O Ring with your thumb Fig 12 3 Insert the complete set of new O Rings in the correct grooves 4 Replace and firmly tighten the Taper Ring X O ring Set Order Code Y900580 N CAUTION Do not disassemble the Taper Ring except for O ring replacement Make certain that the Taper Ring is firmly tightened If the Taper Ring is loose water and air leakage could occur 3 Replacing Non Retraction Valve A Non Retraction Valve is equipped in the Coupling Joint which shuts off the water retraction right at the handpiece head to prevent oral fluids from being sucked into the water line Brasseler USA Coupling Remove the b
3. Bur Depress the Push Button and remove the bur O 4 Connecting Disconnecting the Handpiece Coupling Align the pipes of the coupling and the pipe holes of the hose and push the coupling onto the hose Hold the coupling tightly and fasten the nut of the hose securely Fig 2 2 Insert the handpiece firmly onto the coupling until it clicks to engage Fig 3 Fig 2 N CAUTION Check tightness at the connection between the coupling and the handpiece Handpiece 3 Do not exceed the air pressure of 36psi 2 5 bar Air pressure readings must be checked at the coupling joint as shown in Fig 3 Fig 3 5 Lubrication Supply spray after each use after cleaning the holes and or before autoclaving Push spray nozzle attachment over the SPRAY can nozzle until it firmly seats 2 Insert the spray nozzle in the rear of the handpiece and spray for approximately 2 3 seconds Spray Nozzle Handpiece ye pa SPRAY SPRAY Fig 4 N CAUTION Hold the spray can upright Be sure to hold the handpiece firmly to prevent the handpiece from slipping out of hand by the spray pressure when lubricating Supply lubricant until it comes out of the handpiece head for approx 2 3 seconds 6 Chuck Cleaning Perform the cleaning of the chuck once a week for Push Button Chuck FG bur Nozzle Tip Chuck Cleaning Method I Mount the arrow head spray nozzle tip into the spray port 2 Lubricate chuck directly through the h
4. ack end Gasket Pull and remove the water tube and replace the Non Retraction Valve Gasket Water Tube By Your Side in Dentistry BRASSELER USA DENTAL INSTRU MENTATION One Brasseler Boulevard Savannah GA 31419 To order call 800 841 4522 or fax 888 610 1937 Visit our website www BrasselerUSA com
5. e mechanism Brasseler USA does not recommended the repair and disassembly This may cause the handpiece to perform abnormally and could result in damage failure or accidents Specification Spray Type Minimum Bur Fixing Length 8 0 mm Maximum Bur Length 18 5 mm 8 6 mm x 9 0 mm Optic Glass Rod 2 Caution on burs N CAUTION e Do not use non standard burs The ISO standard shank diameter is 1 5 9 1 60mm Fully depress the Push Button and insert the bur into the chuck until bur is secure Do not use bur when removing the crown do not use bur to pry loose the crown It may cause a malfunction in the handpiece Do not apply too much pressure to the bur Bur may break or bend and become difficult to remove Do not use any bur longer than 18 5mm Do not use bent worn damaged or non concentric burs Such burs can cause damage to the handpiece Do not exceed the bur speed recommended by the bur manufacturer Always use clean burs Unclean burs may allow debris to build up inside chuck causing weak bur retention or premature chuck wear When using shorter than short burs make certain the head diamonds do not come in contact with the chucking mechanism 3 Mounting and Removing the Bur Mounting the bur I Insert the bur until it stops 2 Depress the Push Button 3 Insert the bur into the chuck until it is stops again Fig 4 Release the button Removing the
6. ole where the bur is inserted Fig 5 7 Clean Head System Maintenance _Clean Head Hole I Brush off the debris at the clean head holes Fig 6 Do not use a wire brush 2 Half fill a cup with clean water 3 Rotate the handpiece and immerse half of the handpiece head Fig 7 4 Rotate and stop intermittently the handpiece about 2 to 3 seconds About 3 times z 6 Stop the handpiece and wipe it dry If the dirt is not removed from the hole remove Cigan Pead Pole the turbine and clean it with a brush Fig 6 N CAUTION Use only clean water to maintain the Clean Head System Fig 7 8 Spray Port Maintenance When the spray ports are clogged or spray does not exit evenly from the ports clean the ports as follows Cleaning Wire Remove the bur from the chuck Spray Ports 2 Take out the cleaning wire from the back end of the brush holder Insert the wire straight into the spray ports with caution Do not forcibly insert the wire into the port Damaged or disoriented port could cause the spray to diverge or be directed away from the bur and the cooling efficiency deteriorates 3 After use clean the cleaning wire Push into the brush holder with the pointed end of the Fig 8 wire inward 9 Fiber Optic Maintenance Wipe the Glass Rod clean Fig 9 with an alcohol immersed cotton swab Remove all debris and oil Fig 9 N CAUTION Do not use a sharp tool to clean the cellular glass optic rod It co
7. uld damage the glass and reduce the light transmission If illumination becomes dim please contact Brasseler USA 10 Sterilization Autoclave sterilization is recommended Autoclave sterilization required first time you use and after each patient after lubrication as noted below Autoclave Procedure I Scrub dirt and debris from the handpiece and wipe clean with alcohol immersed cotton swab or cloth Do not use a wire brush 2 Lubricate with spray 3 Insert into an autoclave pouch Seal the pouch 4 Autoclavable up to a max 275 F 135 C ex Autoclave for 20 min at 250 F 121 C or 15 min at 270 F 132 C 5 Keep the handpiece in the autoclave pouch to keep it clean until you use it N CAUTION Do not heat or cool the handpiece quickly Rapid change in temperature could break the cellular glass rod or cause abnormal strain to other metal components Do not wash soak or wipe off the handpiece with oxidizing solutions strong acid superacid solution or sterilizing solution Head Cap Replacing the Turbine Turbine Insert a dummy bur into the chuck 2 Unscrew the Head Cap by turning counter clockwise and remove 3 Push the dummy bur upwards to remove Turbine 4 Clean the interior of the Head casing 5 Insert the new Turbine 6 Replace the Head Cap and firmly screw into place X SX PUO3 Order Code PI 140200 N CAUTION Make sure that the O Ring is removed when removing the Turbine O
Download Pdf Manuals
Related Search
Related Contents
第10号 - 福井大学医学部附属病院 Marley MC Fluid Cooler - SPX Cooling Technologies Weslo Treadmill WLTL34300 User's Manual BOLETIM DO TRABALHO E EMPREGO 37/2014 TDC Double Beam DMX LED light effect User manual - Bax VSM77D, VSM77DL VSM79D, VSM79DL Présentation générale des enjeux du programme annuel Copyright © All rights reserved.