Home

immersion thermostats and dry-blocks

image

Contents

1. 80 Immersion Thermostats Cmn N Thermostat immersion Termotronic II TEMPERATURE CONTROLLABLE FROM AMBIENT 5 C TO 100 C SAFETY STANDARD DIN 12876 SAFETY OVER TEMPERATURE THERMOSTAT WITH SIGNAL LAMP ALARM FEATURES CONTROL PANEL Electronic temperature control Illuminated mains switch 100 temperature sensor Temperature control selector Maximum volume to maintain maximum temperate 20 Heater on indicator lamp litres Heater elements made of INCOLoY stainless ste el Fitted with a stirring circulating pump All parts in contact with liquids made of stainless steel AISI 304 Fixing nut on the side Minimum required tank depth 14 cm MODEL Part No Temp Range Stability Height Width Depth Pump Power Weight JE C exterior cm Pressure Flowrate H 0 W Kg 3000389 Amb 5 to 100 0 2 32 11 16 150 mbar 5l min 1000 2 0 Height measured with the thermometer included It is supplied with a thermometer ACCESSORIES Methacrylate tank Clinic Term Part No Capacity Temp max Height Width Depth Capacity Weight litres Kb usable cm Rack Kg 1000544 8 80 14 16 39 4 2 Racks for the Clinic Term made of AISI 304 stainless steel Racks for 50 micro tubes of 11mm 0 Part No 1000546 Racks for 50 haemolysis tubes and coagulation tests with a diameter of 13 mm Part No 1000545 Racks for 14 tubes with a diameter of 18mm Part No 1000547 R
2. ee B a m _ ND DRY BLOCKS L SA 7 ERMOSTAT di A H 1 Immersion thermostats Analogue control page 100 Immersion thermostats Digital amp Touch screen contro pages 101 to 106 Circulating ultrathermostat page 103 Circulating criothermostat page 103 Bath circulators with thermostatic equipment pages 104 105 Digital amp Touch screen control Immersion thermostat for baths pages 105 106 Refrigerated units for baths page 107 Water recirculators page 107 Thermostat dry blocks page 108 109 Thermo shakers page 109to110 It is characteristic of science that the full explanations are often seized in their essence by the percipient scientist long in advance of any possible John Desmond mr x Lh EQUIPMENT FOR STABLE AND PRECISE TEMPERATURE CONTROL y THERMOSTAT BATHS AND IMMERSION THERMOSTATS c 5 Summary table of the different models QUICK OVERVIEW A Range Model Part No Control Volume m x Stability Set error RS 232 litres AG C 5 100 C Termotronic II 3000389 Analogue 20 0 2 No 5 150 C Digiterm S 150 3000543 Digital ji 20 to 150 C 0 05 1 Yes 5 200 C Digiterm TFT 200 3000544 Touch screen p 20 2 to 100 C 0 05 0 100 C Digit Cool 3001373 Digital 20 GeO beets 1 Yes 100 C 0 05 5 150 C Digiterm S 150 20 3000548 Digital 20 0 05 Yes 5 150
3. C Digiterm S 150 27 3000549 Digital 27 0 05 Yes 5 200 C Digiterm TFT 200 20 3000550 TFT Touch screen 20 0 1 2 Yes 5 200 C Digiterm TFT 200 27 3000551 TFT Touch screen ji 27 0 1 2 Yes to 100 C 0 05 1 5 200 C Ultraterm TFT 200 3000545 TFT Touch screeny 8 to 200 C 01 m Yes to 100 C 0 05 10 100 C Frigiterm TFT 10 3000546 TFT Touch screeny 8 to0 C 0 05 1 Yes to 10 C 0 1 to 100 C 0 05 30 100 C Frigiterm TFT 30 3000547 TFT Touch screen 8 100 C 0 05 1 Yes to 10 C 0 2 5 upto90 C Interheater 6001491 Digital 20 l min 1 No Refrigerated coils 20 20 C Frigedor 3000778 No controller 20 No 20 20 C Frigedor Reg 3001214 Digital 20 1 5 1 5 No THERMOSTATS DRY BLOCKS Range Model Control Blocks 1 Blocks 3 Blocks 4 Stability 30 200 C Digital 7462200 0 75 C With multiple adapters 30 200 C Multiplaces Digital ji 7471200 0 75 C With multiple adapters FIXED 37 C Glinic bloc 7001569 0 5 C Capacity 20 tubes of 75 x 13mm VAC FIXED 37 C Bio bath 7001561 0 5 C Capacity 15 cuvettes of 10 x 10mm 5 60 C TRM 4 Digital ji 5109200 0 5 C For 4 microtiter plates 5 100 C TR100 6 Digital 5109100 0 5 C WITH SHAKING With multiple adapters u with microprocessor 5 ambient 5 C BATH TEMPERATURE LIQUIDS GUIDE Silicon oil Ethylene glycol 50
4. cell culture Thermo control to dry boiling evaporation concentra tion hydrolysis digestion etc COMMON FEATURES Dry block systems have several advantages over wet contact methods such as no risk of evaporation of he ating liquid higher working temperatures better long term temperature stability and no sample cross conta mination or germination of bacteria in the bath nutes or continuous operation Over temperature alarm Heating elements are distributed evenly across the con tact surface maintaining an even distribution of heat Easy to use digital temperature and time control with a digital display 3 Digits Built in temperature sensor Pt 100 Interchangeable blocks made of anodised DURAL alloy to accommodate a variety of tube diameters Customer specific sizes also available External case made of epoxy covered steel with an AISI 304 stainless steel top 1 2 CONTROL PANEL 1 Digital display showing temperature and time in minutes 2 Indicator show displayed parameter Time or tempe rature 3 Push button selector to show time or temperature 4 Push button increase displayed value 5 Push button decrease displayed value 6 Push button Start Stop 7 Over temperature alarm indicator 3 4 7 6 Digital temperature calibration Timer from 1 to 999 mi Dry block heater for tubes Tembloc in n imi di e E er s me ne us S m i m s i qu t m s ne d ins mim m
5. Width Depth Power Weight C C AG exterior cm W Kg 7471200 30 200 0 75 1 5 0 1 11 31 31 700 74 Supplied complete with thermometer 0 200 C and extraction tool for blocks gt Dry blocks FIXED TEMPERATURE OF 37 C WITH CHECK THERMOMETER SAFETY NORM EN 61010 OVER TEMPERTURE CUT OUT FITTED CLINIC BLOC Capacity 20 tubes 5x4 of 75x13 mm VAC Part No 7001569 CLINIC BLOC 1537 Capacity 15 cuvettes 5x3 of 10x10 mm Part No 7001570 MODEL Part No Height Width Depth Stability Power Weight exterior cm ME W Kg 7001569 11 18 28 0 5 10 2 4 For VAC tubes 75x13 For cuvettes 10x10 7001570 1 18 28 0 5 10 24 Part No 7001569 Part No 7001570 BIO BATH Capacity 8 tubes 5x4 of 75x13 mm VAC MODEL Part No Height Width Depth Stability Power Weight exterior cm ED W Kg 7001561 8 8 96 7 0 5 8 0 5 men gt Thermo shaker TRM 4 for Microtiter plates La WITH ELECTRONIC CONTROL AND DIGITAL DISPLAY OF TEMPERATURE SHAKING SPEED AND TIME H FOR TEMPERATURES FROM AMBIENT 5 C TO 60 C STABILITY 0 5 C APPLICATIONS For clinical analysis immunology and nutritious quality control use FEATURES External ABS case with a platform for heating and shaking 2 4 96 well Microtiter pla tes Upper lid with aluminium plate coated inside and simultaneous heating system to the main platform Digital display of current and set
6. point temperature time and shaking speed parame ters Acoustic and luminous indications at the end of the cycle and due to malfunction in temperature or time programmed A built in motor generates a uniform movement depending on the speed program med protected to over temperature with auto switch off and switch on activation Temperature calibration to meet the user s needs Protection device for over temperature that provides safety and reliability CONTROL PANEL LCD display indicating temperature speed in r p m and time Push button SET to program temperature speed in r p m and time Push button increase value Push button v decrease value Push button START STOP for starting and stopping the shaking system Push button OFF for any function Cover inner plate with heating system SPECIFICATIONS Temperature Ambient 5 C to 60 C Heating time lt 23 min to 60 C Shaking range 100 1200rpm Orbital rotation 2mm Timer From 1 min to 99h 59 min MODEL Part No Temperature Stability Block Height Width Height Width Depth Power Weight5 C C homogeneity C platform cm exterior cm W Kg 5109200 ambient 5 to 60 0 5 0 5 219 30 18 40 39 132 9 5 Dry blocks Ji COMEC Metallic dry block thermo shaker TR100 G WITH ELECTRONIC CONTROL AND DIGITAL DISPLAY OF TEMPERATURE SHAKING SPEED AND TIME FOR ADJUSTABLE TEMPERATURE FROM AMBIENT 5 C UP TO 100 C APP
7. 200 with lid at 100 C Graph of temperature and time for the Digiterm 100 and 200 units with capacity of 20 litres Tests completed with Silicon oil up to 200 C A Digiterm TFT 200 with lid at 200 C B Digiterm TFT 200 with lid at 100 C B Digiterm TFT 200 no lid at 90 C C Digiterm S 100 with lid at 100 C D Digiterm S 100 with no lid at 90 C Bath circulators Digiterm S 150 CUVETTES SET OF 20 AND 27 L CAPACITY WITH THERMOSTATIC EQUIPMENT INCLUDED FORT TEMPERATURES FROM AMB 5 150 C STABILITY 0 05 C RESOLUTION 0 1 C 21 litres capacity baths take 20 more time to reach the same temperature SAFETY SAFETY STANDARD DIN 12876 SAFETY ADJUSTABLE OVER TEMPERATURE CUT OFF WITH MANUAL RESET LOW LIQUID LEVEL CUT OFF MODELS Part No Temperature Cuvettes Height Width Depth Height Width Depth Pump Power Weight Range C Capacity interior cm exterior cm Pressure Pump rate W Kg litres mbar l min DIGITERM S 150 20 3000548 150 20 15 30 29 36 55 35 150 12 1060 9 2 DIGITERM S 150 27 3000549 150 27 20 30 29 41 55 35 150 12 1060 10 8 Immersion Thermostats Bath circulators Digiterm TFT 200 e WITH IMMERSION THERMOSTAT DIGITERM TFT 200 CUVETTES SET OF 20 AND 27 L QULA pe FROM AMBIENT 5 C TO 200 C STABILITY 0 1 C SET ERROR 2 C RESOLUTION 0 1 C Fst SAFETY CONFORMS TO THE DIN 12876 STANDARD ADJUSTABLE OVER TEMPERATURE SAFETY CUT O
8. 900 mm Cooling coil 0 45 mm Coil length 150 mm a 9 9 9 9 3 8 0 20 40 60 80 100 120 Minutes Graph showing the cooling performance of the 8 litre 0 Frigedor With insulated stirring tank MODELS Part No EE range FRIGEDOR 3000778 20 to 20 FRIGEDOR REG 3001214 20 to 20 MODEL FRIGEDOR No temperature controller incorporated Continually operates the compressor CONTROL PANEL Mains switch with ON indicator lamp Refrigerated cooling coils for baths Frigedor and Frigedor Reg TEMPERATURES FROM 20 C TO 20 C MODEL FRIGEDOR REG Equipped with a temperature controller with digital con trol and display Includes a Pt 100 temperature probe Resolution 1 digit CONTROL PANEL Mains switch with indicator ON lamp Digital tempe rature controller with push buttons connector for the Pt 100 temperature probe See page 106 hh Stability Height Width Depth Cooling potential Power Weight mG exterior cm W Kg 41 21 34 to 20 C 50 W 289 14 1 5 41 21 34 to 20 C 50 W 289 14 We recommend our thermally insulated baths see page 106 FROM AMBIENT 5 C TO 90 C SAFETY STANDARD DIN 12876 OVER TEMPERATURE SAFETY ADJUSTABLE THERMOSTAT WITH MANUAL RESET DESCRIPTION Water circulation unit designed to feed closed water lo op circuits for condensers distillation columns reactor jackets v
9. ENT 5 C TO 100 C With external refrigeration from 20 to 100 High precision temperature control SAFETY STANDARD DIN 12876 1 SAFETY OVER TEMPERATURE THERMOSTAT WITH ADJUSTABLE MANUAL RESET 2 OVER TEMPERATURE ALARM 3 LOW LIQUID LEVEL FLOAT FEATURES Maximum working volume to maintain maximum temperature 20 litres A clamp and finger screw attach the unit to the tank alternatively the extendible support bridge accessory can be used Minimum fixing depth to the tank 14 cm RS 232 interface for computer control or printing data CONTROL PANEL 1 Bath temperature display indicator 2 Set temperature display indicator 9 3 Heater function light indicator 4 Set value decrease button 3 5 Set value increase button 4 5 MODELS Part No Control range Stability Height Width Depth Pump Power Weight a ME exterior cm Pressure Flowrate H 0 W Kg DIGITERM 150 3000543 Amb 5 to 150 0 05 28 18 19 150 mbar 5 6 l min 1060 3 9 Accessories See page 10D Immersion thermostat with TFT touch screen Digiterm TFT 200 ADJUSTABLE TEMPERATURE FROM AMBIENT 5 C TO 200 C With external refrigeration from 20 to 200 High precision temperature control SAFETY STANDARD DIN 12876 1 SAFETY OVER TEMPERATURE THERMOSTAT WITH ADJUSTABLE MANUAL RESET 2 OVER TEMPERATURE ALARM 3 LOW LIQUID LEVEL FLOAT FEATURES Maximum working volume to maintain maximum temperature 20 litres A clamp and finge
10. FF WITH ADJUSTABLE MANUAL RESET LOW LIQUID LEVEL CUT OFF ELECTRICAL FAULT ALARM FEATURES Temperature sensor probe Pt 100 Heating element made of stainless steel INCOLOY resistant to high temperatures and corrosive en vironments Circulation pump with flow rate suitable for external temperature control for Polarimeters refrac tometers viscometers etc Cooling coil to maintain ambient temperatures using tap water External temperature control connection using Pt 100 probe see page106 External metal case with a corrosion resistant epoxy coating All parts in contact with liquid are made of AIS 304 stainless steel Handles at the side and drain tap MODELS Part No Temperatura Cuvettes Height Width Depth Height Width Depth Pump Power Weight Range C Capacity interior cm exterior cm Pressure Pump rate W Kg litres mbar l min TFT 200 20 3000550 200 20 15 30 29 36 55 35 150 12 2060 10 200 27 3000551 200 27 20 30 29 41 55 35 150 12 2060 12 ACCESSORIES for the DIGITERM S 150 and DIGITERM TFT 200 Made of AISI 304 stainless steel 1 Gable lid Part No 3001295 2 Lifting rack support Capacity 3 tube racks Part No 1001296 3 Tube racks for lifting rack support Part No For tubes Capacity Rack Height Width Depth mm tubes exterior cm 1001202 13 36 8 8 2 23 6 1001203 16 24 8 82 23 6 1001204 20 24 8 82 23 6 Immersion thermostat for baths Digit Cool DIGITAL SELECTOR AND TEM
11. LICATIONS Wide applications of TR100 G for DNA analysis lipids and other cellular components extraction DNA libraries creation DNA amplification electrophoresis pre denatura lization serum solidification etc FEATURES External ABS case with multiadapter device for different blocks depending on the analysis to be made Digital display of current and set point temperature time and shaking speed parameters Acoustic and luminous notification at the end of the cycle and due to malfunction in temperature or time programmed A built in motor generates a uniform movement depending on the speed program med protected to over temperature with auto switch off and switch on activation Temperature calibration to meet the user s needs The thermostat includes a heater platform to adapt multiple blocks depending on the analysis to be made Protection device for over temperature that provides safety and reliability CONTROL PANEL LCD display indicating temperature speed in r p m and time Push button SET to program temperature speed in r p m and time SPECIFICATIONS Push button increase value Temperature Ambient 5 C to 100 C Push button v decrease value Heating time lt 23 min to 100 C Push button START STOP for starting and stopping the shaking system Shaking range 200 1500rpm l Push button OFF for any function Orbital rotation 2mm Timer From 1 min to 99h 59 min MODEL Part No Temperature Stability Bl
12. PERATURE CONTROL ADJUSTABLE FROM 0 TO 100 C lt STABILITY 100 C 0 1 C AND AT 0 C 0 05 C SET ERROR 0 1 C RESOLUTION 0 1 C FEATURES Maximum volume to achieve the working temperature 20 litres Autonomous unit with cooling sy stem Minimum depth of the elements with contact with the liquid 15 cm Compressor unit built in Hermetically sealed compressor RS 232 out put to a computer control or printer Portable control and stirring unit with lifting handle CONTROL PANEL Main power switch LCD Display showing working parameters Push button configuration selector Push button parameter selection Push button increase decrease set value Start Stop push button Digitcool thermostat with bath MODEL and 4 place ring set lid Part No Control Range Height Width Depth Pump Power Power Weight AG exterior cm Pressure Flow H20 W H P Kg 3001373 0 100 45 21 51 150 mbar 12 l min 1460 1 5 22 Immersion Thermostats du err perm ACCESSORIES for thermostatic unit digit cool 1 Lifting rack support DNE Capacity 3 tube racks Part No 1001296 Stainless steel baths Double skinned with an AISI 304 stainless steel exterior with a bath of AISI 304 stainless steel interior MEUM mm tubes exterior cm 1001202 13 36 0 8 2 23 6 1001203 16 24 8 82 23 6 1001204 20 24 8 82 23 6 Ring set lid 105 80 60 and 37 mm 8 MODELS reduction
13. acks for 8 cuvettes for spectrophotometers 10 mm square standard for monotest flask of diffe rent sizes Part No 1000548 Note The methacrylate tank should not be used over 60 C Methacrylate transparent tank Designed to be used with the immersion thermostat Termotronic II Part No Capacity Temp max Height Width Depth Capacity Weight litres ab usable cm Rack Kg 1000397 7 60 10 20 38 4 2 Rack for 24 haemolysis tubes up to 13 mm j made from AISI304 S S Part No 1002532 Rack for 14 test tubes up to 16 mm 0 made from AISI 304 S S Part No 1002531 Metal baths Manufactured with a double external AISI 304 stainless steel skin and an AISI 304 stainless steel pressed bath interior Part No Capacity Height Width Depth Height Width Depth Weight 3 litres usable cm exterior cm Kg 6000390 9 15 29 22 20 34 28 9 9 6000391 12 15 30 31 20 37 35 4 3 2 6000392 20 15 48 30 20 55 35 6 6 6000393 27 20 48 30 25 59 39 7 6 6001093 45 15 62 50 23 70 56 11 With drain tap and lifting handles Immersion Thermostats IMMERSION THERMOSTATS WITH DIGITAL AND TOUCH SCREEN CONTROL The most precise solution for maintaining constant liquid temperatures SAFETY STANDARD DIN 12876 ADJUSTABLE OVER TEMPERATURE SAFETY THERMOSTAT WITH MANUAL RESET AND LOW LIQUID LEVEL FLOAT SENSOR COMMON FEATURES Temperature probe Pt 100 Heating element made of stainless steel INCOLOY resistan
14. e me d i sn E Rs RON ACCESSORIES Metal blocks size 105 x 55 mm high Part No 7000346 for 34 x 6 mm 0 tubes 7000714 for 18 x 1 5 ml Eppendorf tubes 7001224 for 24 x 12 mm 0 tubes 7001618 for 18 x 16 mm f tubes 7000208 for 8 x 20 mm f tubes 7000256 for 6 x 25 mm 0 tubes 7000715 Blank block with no holes for customized demand MODEL Part No Temperature Stability Homogeneity Set error Resolution Height Width Depth Power Weight EU EU E exterior cm W Kg 7462200 30 200 10 75 15 2 1 11 19 29 350 3 7 Supplied complete with thermometer 0 200 C and extraction tool for blocks icu Dry Block heater for tubes Multiplaces ACCESSORIES Metal Blocks 55 high x 95 wide x 75 mm deep Part No 7000306 For 30 x 6 mm 0 tubes total 3 blocks 90 tubes 7000716 For 20 x 1 5ml Eppendorf tubes total 3 blocks 60 tubes 7031220 For 20 x 12 mm f tubes total 3 blocks 60 tubes 7031612 For 12 x 16 mm 0 tubes total 3 blocks 36 tubes 7003208 For 8 x 20 mm 0 tubes total 3 blocks 24 tubes 7001256 For 6 x 25 mm 0 tubes total 3 blocks 18 tubes 7000717 Blank block without holes can be customised to customer requirements 7001474 Block for 15 cuvettes 10 x 10 Capacity 3 blocks 7001475 Block for 96 well microplates of 1 2 ml Capacity 1 block MODEL Part No Temperature Stability Homogeneity Set error Resolution Height
15. emperature high limit low limit Connection device for external temperature Pt100 probe Automatic calibration of a point Permanent view of set temperature DIGITERM TFT 200 ULTRATERM TFT 200 FRIGITERM TFT 10 FRIGITERM TFT 30 Specific functions of models with touch screen FA v Acoustic and visual alarm Safety thermostat TS by software Clock and calendar Mechanic safety thermostat TS Single or cyclic On Off programming USB and RS 232 output Up to 10 work programs PC software 1235 Up to 6 segments per program User manual on screen 3 5 Stability time in each segment from 1 min to 99h Configurable parameters Date time temperatu L Power control program between 10 and 100 re correction data collection interval language Pump 00 10 Alarms and events storage English Spanish and French C F selection 3 2 Flow 00 1 0 Probe error detection over temperature and low temperature limit 00 00 Self Diagnostics Temperature control auto tuning Network failure detection and saving Circulation pump speed control eae 3 e Over temperature and low temperature alarms and me 10 points automatic calibration morization date start time end time and temperature Immersion Thermostats 1m Immersion thermostat with digital control Digiterm 150 ADJUSTABLE TEMPERATURE FROM AMBI
16. events external condensation or heat loss Methacrylate baths Maximum temperature 60 C working temperature range from 40 C to 90 C MODELS MODELS Part No Capacity Height Width Depth Thickness Part No Capacity Height Width Depth Height Width Depth Weight litres usable cm mm litres usable cm exterior cm Kg 1000394 8 15 18 31 6 1000544 9 5 14 5 16 5 39 6 1000395 18 15 23 40 8 1000396 30 20 30 50 8 6003901 9 15 29 22 24 40 34 6 6003921 20 15 48 30 24 61 41 g 6003931 27 20 48 30 29 61 41 11 With drain tap and lifting handles Removable constant liquid level Suitable Thermometer for any type of bath pu Adjustable height to obtain the required Eum liquid level Part No Thermometer support Stainless steel suitable Suitable for Tectron Bio immersion 6001400 Bath depth up to 15 cm for thermometer Fixation aperture up to 40 mm thermostat Scale 20 to 100 C 6001800 Bath depth up to 20 cm Part No 6000896 Part No 3009100 ro Erreger Immersion Thermostats Aw J APPLICATIONS Designed for bath and tank applications that require below ambient temperatures COMMON FEATURES The unit is bench mountable and contains within the epoxy coated case a CFC free hermetically sealed com pressor with condenser and evaporator the cooling coil is made of AISI 304 stainless steel COIL DIMENSIONS Refrigerated immersion length
17. idth Depth Height Width Depth Pump Power Compresser power Weight litres sb usable cm exterior cm Pressure Flowrate 0 W H P Kg FRIGITERM 10 3000546 8 10 100 12 20 14 36 66 44 150 mbar 12 l min 1150 1 8 28 FRIGITERM 30 3000547 8 30 100 12 20 14 36 66 44 150 mbar 12 l min 1460 3 8 30 Immersion Thermostats du N PRECISE CIRCULATING BATHS Choice of baths and immersion circulators Digiterm S 150 and Digiterm TFT 200 CONTROLLABLE TEMPERATURES FROM AMBIENT 5 C TO 150 OR 200 C CAPACITY FROM 20 TO 27 LITRES APPLICATIONS Incubation processes Enzymatic reactions Fermentation laboratory cultures in general COMMON FEATURES Double skinned baths with an AISI 304 stainless steel internal tank with an AISI 304 stain less steel external for convenience handles at the side and drain tap are provided as stan dard A detachable immersion thermostat for controlling stirring and temperature is fit ted A cooling coil with the use of tap water or cooled re circulator can be used to maintain ambient temperatures Internal or external circulation pump Polarimeters refractome ters and viscometers etc a m M za MZ 30 0 15 30 4 60 7 90 105 120 Minutes Minutes Graph of temperature and time for the Tectron Bio 100 and Digiterm S 100 and Digiterm IFT 200 units with capacity of 20 litres Tests completed with water up to 100 C A Digiterm TFT
18. iscometers electrophoresis baths etc desig ned specifically for Constant temperature Constant pump rate of refrigerated fluid Closed loop circuit avoids the build up of scale in co oling coils and cooling circuits FEATURES Digital electronic temperature regulation Circulation flow 20 L min Inox covered steel case RS 232 USB and Ethernet output for recording tem MODEL Part No Height Width Depth Regulation range exterior cm AE 6001491 70 43 56 5 to 90 y Water recirculators Interheater peratures Hose connectors O 12mm internal 230V single phase INTERHERATER Heating power 2 or 4 KW control panel selectable CONTROL PANEL Mains switch Digital temperature control Pressure gauge Water level in the reservoir Autotunning function for optimizing the temperature control of each facility Supports 9 programmable temperature profiles inclu ding temperature ramps and steps ACCESSORY Power Weight Roll of 25 m of reinforced sili W Kd cone hose 4100 22 number 1001540 Immersion Thermostats 4 THERMOSTAT DRY BLOCKS um WITH DIGITAL ELECTRONIC CONTROL OF TEMPERATURE AND TIME SAFETY CONFORMS TO EN 61010 DIRECTIVE OVER TEMPERATURE CUT OUT SYSTEM High precision Free from contamination APPLICATIONS Clinical biochemical and chemical laboratories Incubation of DNA enzyme assays residual testing in dairy incubation and fusion of AGAR
19. ock Height Width Depth Power Weight C C homogeneity C exterior cm W Kg 5109100 ambient 5 to 100 0 5 0 5 18 21 30 88 9 5 ACCESSORIES ABS coated metallic blocks adapted to TR100 G thermostat by means of fixing screws to the block Easy to clean and autoclavable 1222325 For 24 tubes of 8 Timm For 12 tubes of 15 ml For 6 tube of 50 ml Depth 30 mm f Up to 15 mm f Up to 28 mm Part No 5109101 Depth 100 mm Depth 100 mm Part No 5109102 Part No 5109103 For 96 microtubes of 0 2 ml For 54 microtubes of 0 2 ml For 15 microtubes of 0 5 ml For 35 microtubes of 1 5 ml For 35 microtubes of 2 ml with polypropylene lid with polypropylene lid and 20 microtubes of 1 5 ml with polypropylene lid with polypropylene lid Part No 5109104 Part No 5109105 with polypropylene lid Part No 5109107 Part No 5109108 Part No 5109106 Thermocycler for thermal cycles B960 See page 238 Dry blocks
20. r screw attach the unit to the tank alternatively the extendible support bridge accessory can be used Minimum fixing depth to the tank 14 cm RS 232 USB and Ethernet output CONTROL PANEL 125 1 Set current temperature indicator 3 5 2 Pump flow indicator 3 3 Stop button Pimp 00 10 4 Start button 2 32 Flow 00 10 5 Push up parameter 00 00 6 Push down parameter 3 7 Ramps cycles button 8 Set current time indicator in hours minuts 9 Return button MODELS Part No Control range Stability Height Width Depth Pump Power Weight 25 ED exterior cm Pressure Flowrate 0 W Kg DIGITERM TFT 200 3000544 amb 5 to 200 at 100 C 0 05 at 200 C 01 28 18 19 150 mbar 5 6 l min 2060 4 5 Accessories See page 106 Immersion Thermostats Recirculation thermostat Ultraterm TFI 200 ADJUSTABLE TEMPERATURES FROM AMBIENT 5 C TO 200 C SAFETY STANDARD DIN 12876 SAFETY OVER TEMPERATURE THERMOSTAT WITH ADJUSTABLE MANUAL RESET LOW LIQUID LEVEL SENSOR PROTECTION FEATURES Maximum working volume to maintain maximum temperature 8 litres AISI 304 stainless steel top and lid with an inner tank of AISI 304 stainless steel Complete with a pump for internal and external liquid circulation with inlet and ou tlet connectors A cooling coil to maintain ambient temperatures using tap water is also provided A RS 232 inte
21. rface for print out or computer control comes as standard A drain tap is also fitted MODEL Part No Capacity Control range Stability Height Width Depth Height Width Depth Pump Power Weight litres C al usable cm exterior cm Pressure Flowrate 0 W Kg 3000545 8 From amb 5 to 200 C to 100 C 0 05 15 20 14 36 28 36 150 mbar 12 l min 2060 9 5 With external refrigeration to 200 C 0 1 from 20 to 200 Refrigerated recirculation baths Frigiterm TFT 10 and Frigiterm TFT 30 ADJUSTABLE TEMPERATURE FROM 10 C TO 100 C STABILITY 0 C TO 100 C 0 05 C 10 C 0 1 C ADJUSTABLE TEMPERATURE FROM 30 C TO 100 C STABILITY 0 C TO 100 C 0 05 C 30 C 0 2 C SET ERROR 1 C RESOLUTION 0 1 C SAFETY STANDARD DIN 12876 SAFETY OVER TEMPERATURE THERMOSTAT WITH ADJUSTABLE MANUAL RESET LOW LIQUID LEVEL SENSOR PROTECTION FEATURES Maximum working volume to maintain maximum temperature 8 litres SS AISI 304 stainless steel top and lid with an inner tank of AISI 304 stainless steel oo Complete with a pump for internal and external liquid circulation with inlet and ou SS pu O tlet connectors A drain tap is placed at the side of the unit a A hermetically sealed compressor is mounted on anti vibration mounts A RS 232 interface for connection to a printer or computer _ MODELS Part No Capacity Control range Height W
22. rings and a check thermome PartNo Capacity Height Width Depth Height Width Depth Weight ter location hole in the lid litres usable cm exterior cm Kg Capacity 4 places Part No 1001374 6000332 20 15 48 30 20 55 39 6 6 Digitcoo thermostat with bath 6000393 27 20 48 30 25 59 39 7 6 and 4 place ring set lid ACCESSORIES FOR IMMERSION THERMOSTATS _ Pt100 temperature sensor with handle ea 0 4 mm 0 x 135 mm long submersion EN ME ey p Supplied with a 150cm cable and connector Part No 1000893 Extension support bridge Made of AISI 304 stainless steel adjustable to fit the immersion thermostat models Tectron and Digiterm Support for apertures from 22 to 44 cm across Part No 6001092 Stainless steel baths Double skinned with an AISI 304 stainless steel exterior and internal bath of AISI 304 stainless steel MODELS Part No Capacity Height Width Depth Height Width Depth Weight litres usable cm exterior cm Kg 6000390 9 15 29 22 20 34 28 3 9 6000391 12 15 30 31 20 37 35 4 3 6000392 20 15 48 30 20 55 35 6 6 6000393 27 20 48 30 25 55 35 7 6 6001093 45 15 62 50 23 70 56 11 With drain tap and lifting handle Stainless steel baths thermally insulated Ideal for low temperatures Suitable for J P Selecta refrigerated units Similar to our other bath but with additional in ternal expanded foam insulation that pr
23. t to high temperatures and corrosive environments Circulation Pump for internal or external temperature control for Polarimeters refractometers and viscometers etc Cooling coil to maintain ambient temperatures using tap water External temperature control connection using a Pt 100 probe see page 106 External metal case coated in a corrosive resistant epoxy All parts in contact with liquid are made of AIS 304 stainless steel PARTS THAT ARE IN CONTACT WITH LIQUID Safety over temperature thermostat Liquid level float Cooling coil Heating element made of stainless steel INCOLOY that can withstand high temperatures and is corrosion resistant Refrigeration coil connections Pt 100 temperature probe Circulation pump Pump outlet for external circulation Circulating pump outlet Outlet nut of the fluid flow fixed in A or B interchan geable A Internal stirring within the tank B External circulation P 4 0 FLOW OUTPUT Cuvette inner circulation level Up to 7 05 Flow l m External circulation level raised to a meter Up to 5 16 Tests made with silicone tubes of 8 mm internal 0 ee TWO DIFERENT CONTROL SYSTEMS amp A Digital display and B TFT touch screen ID DIGITERM S 150 Specific functions of models with digital screen Low liquid level indication Real time temperature reading Heating indicator Display resolution 0 1 Monitoring t

Download Pdf Manuals