1. DELUGE LED WAV 50W User Manual Please read the instructions carefully before use Innovation Quality Performance particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 14A 9 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 7 Troubleshootino Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A 1 The fixture does not work no light Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B 2 Not responding to DMX controller DMX LED should be on If not check DMX connectors cables to see if link properly If the DMX LED is on and no response to the channel check the address settings and DMX polarity If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interfere
2. Cooling system for cooling down the unit 3 2 Installation A Product Items User manual 60lens B Mounting You can install the unit on the truss or ceiling Use clamps to fix the unit to truss Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure Also always use a safety cable that can hold 10 times of the weight of the unit when installing the fixture C Replace the lens You could replace the other lens if you want to as following picture You should screw the lens roller to take it down as NO 1 and bring the lens out as No 2 Then you could replace the lens that you want to Notes the lens roller has two slots for the lens you should pay more attention that the latest slot is for the 34 lens and the far slot is for 60 lens 6A To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions without any change after idling one minute Back to the functions without any change press MENU button The main functions are shown below node DMX512Address Setting Master Slave Mode LED on LED off Normal Inversion MENU Manual te
3. mable materials close to the unit while operating as it is fire hazard Look over power wires carefully replace immediately if there is any damage Never run on for a long time lest shortening lifespan Avoid any inflammable liquids water or metal objects entering the unit Once it happen cut off the mains power immediately Do not operate in dirty and dusty environment also cleaning fixtures regularly 3A Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 1 512 usually O amp 1 are equal to 1 12A 4 3 DMX Controller e Do not allow children to operate the fixture e Do not touch any wire during operation as there might be a hazard of electric shock Use universal DMX co
4. nce to DMX interface circuit Some fixtures don t respond to the easy controller You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not receive DMX signal 2 E 1 2 Check microphone to see if it is good by tapping the microphone One of the channels is not working well The stepper motor might be damaged or the cable connected to the PCB is broken The motor s drive IC on the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or 13A TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How To Set The Fixture 4 How To Control The Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning 2A 1 Safety Introductions A N Please read the instructions carefully which includes important 6 DMX512 Connections WARNING information about the installation operation and maintenance The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels e Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this i
5. nstruction booklet LSSSASE e All fixtures are intact from the manufacturer please operate follow up the user manual JON MD artificial fault are not under guarantee repair e Unpack and check carefully that there is no transportation damage before using the y unit L J e The unitis for indoor use only Use only in a dry location e Do install and operate by operator el COMMON e Use safety chain when fixes the unit Don t handle the unit by taking its head only but always by taking its base OMe IM PLT D l OM OUTPUT e The unit must be installed in a location with adequate ventilation at least 50cm from DMX adjacent surfaces Termination reduces signal errors and avoids signal e Be sure that no ventilation slots are blocked otherwise the unit will be overheated transmission problems and interference It is always advisable to connect a DMA terminal Resistance 120 ohm 1 4W between pin2 DMA and Pin3 DMX of the last fixture e Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 C Don t operate it where the temperature is higher than this Don t connect the device to any dimmer pack First run there will be smoke or smells and all disappearing a few minutes later Make sure there are no flam
6. ntroller to control the units you have to set DMX address from 1 to e Avoid power wires together around other cables 512 channel so that the units can receive DMX signal e Disconnect mains power before fuse lamp replacement or servicing Press the MENU button up to when the Hddr ig showing on the display Pressing ENTER e Replace fuse only with the same type button and the display will blink Use DOWN and UP button to change the DMX512 address e In the event of serious operating problem stop using the unit immediately Once the address has been selected press and keep ENTER button pressed up to when e Never turn on and off the unit time after time the display stops blinking or storing automatically one minute later To go back to the e The housing the lenses or the ultraviolet filter must be replaced if they are visibly functions without any change press the MENU button again If you use please refer to the damaged following diagram to address your DMX512 channel for the first 4 units e Do not open the unit as there are no user serviceable parts inside e Never try to repair the unit by yourself Repairs carried out by unskilled people can lead 3 channels BRE PY BEEE to damage or malfunction Please contact the nearest authorized technical assistance center e Disconnect the mains power if the fixture is not used for a long time 5 DMX512 Configuration e Do use original packing materials once transport it again DMX512 Configurati
7. on e Do not look directly at the LED light beam while the fixture is on 3 CH mode 255 100 000 009 f Blackout 000 007 f White For power supply do not connect in series much more than 7 units use another mains supply for next 7 units Clockwise Colorz 5 Technical Specifications Spied 128 186 Fast to stow e Voltage AC 100 240V 50 60Hz eee ene e LED 1X50W LED e Fuse T 6 3A e Power consumption 80 W e Dimension 279 x226 x 191 mm 135 2451 Slow to Fast 187 196 Anticlockwise e Weight 4 kg pcs 246 255 5 topped 197 255 Slow to fast Anticlockwise 11A 4A 3 How To Set The Fixture 3 1 Control Panel a Display To show the various menus and the selected functions 2 LED MASTER On Master Mode SLAVE On Slave Mode Soma on nonen No function Button lUP To go forward in the selected functions ENTER To confirm the selected functions 5A 4 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By DMX controller No need to turn the unit off when you change the DMX address as new DMX address setting will be effected at once Every time you turn the unit on it will show wav on the display and move all the motors to their home position After that the unit will be ready to receive DMX signal or run the built in programs 4 1 Master Slave Built In Preprogrammed F
8. out any change after one minute Back to the functions without any change press MENU button again 3 Manual setting color Press the MENU button up to when the dau is shown on the display Pressing ENTER button and use DOWN and UP button to select LOLO 0 255 or 8A
9. run the auto test Back to the functions without any change press MENU button Back to the functions without any change press MENU button Lorie Eee Temperature Test Press the MENU button up to when the t ene is blinking on the display Pressing ENTER button and the display will show the temperature of the unit To go back to the functions press the MENU button again cot rinic S Fixture Hours Press the MENU button up to when the rhe is blinking on the display Pressing ENTER button and the display will show the number of working hours of the unit To go back to the functions press the MENU button 1 as Software version Press the MENU button up to when the ber is showing on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again Factory reset all channels Press the MENU button up to when the inte is shown on the display press ENTER button to setup Back to the functions without any change press MENU button 9A 4 Only for remote control Connecting with CA 8 UC3 to control the unit for Stand by Function and Mode function DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal Mains input Connect to supply mains power for the unit Mains output Connect and supply mains power for the other unit 9
10. st self test ino Temperature heH Fixture Hours Software Version SP Reset 7A DMX 512 Address Setting Press the MENU button up to when the Addl is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically exit menu mode without any change after one minute Back to the previous functions without any change press MENU button l _ Itt Slave Mode Press the MENU button up to when the Ol is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the HA set the fixture as master or Gi Ti set the fixture as slave Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the functions without any change press the MENU button again T a n I1 AI Display Inverse Press MENU button until is blinking on the display Use DOWN and UP button to select display normal or display inverse press ENTER button to setup LED display Press the MENU button up to when the Led is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select display always on or oF Fldisplay off 20 seconds after exit menu mode Once select press ENTER button to setup or exit menu mode with
11. unction The fixture will allow you to link 2 fixtures together and operate without a controller In Master Slave mode the first fixture whose DMX input jack has with nothing connect need to set as master and the other unit need to set as slave 1 via menu then the first unit will control the other to give an automatic and synchronized light show This function is good when you want an instant show Any fixture can act as a Master or as a Slave 4 2 Easy Controller by CA 8 A The easy remote control is used only in master slave mode By connecting to K the 1 4 microphone jack of the first unit you will find that the remote controller ie on the first unit will control all the other units for Stand by Function and Mode i gai if 1 14 nt ae selection Blackout To blackout all the fixture F Hold and press for 3 seconds unction Water wave speed 1 3 1 Clockwise counterclockwise color Color speed 1 3 2 choose color LED OFF LED ON EEE DINING 10A bo C Lint unuc 000 2555 clockwise counterclockwise or di 1425 255 press ENTER button to confirm and use DOWN and UP button to adjust the value once select press ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function without any change press the MENU button Self test Press the MENU button up to when the best is shown on the display Pressing ENTER button to

Download Pdf Manuals

image

Related Search

DELUGE deluge definition deluge torrent deluge system deluge valve deluge download deluge synonym deluged meaning deluge sprinkler system deluge rpg 2 deluge pronunciation deluge fire system deluge windows 11 deluge bittorrent deluge torrent client deluge the shoreless sea deluge vs qbittorrent deluge valve system deluge crossword clue deluge docker deluge windows deluge skid deluge plugins deluge synthstrom deluge password deluge film