1. 48 Barcode scanner configuration guide 13 Codabar Enable Disable Codabar Parameter 07h To enable or disable Codabar scan the appropriate bar code below Enable Codabar 01h Disable Codabar 00h Set Lengths for Codabar Parameter L1 18h L2 19h The length of a code refers to the number of characters i e human readable characters including check digit s the code contains Lengths for Codabar may be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length Select this option to decode only those codes containing a selected length For example select Codabar One Discrete Length then scan 1 4 to decode only Codabar symbols containing 14 characters Numeric bar codes begin on page 56 To change the selection or cancel Codabar One Discrete Length an incorrect entry scan Cancel on page 57 Two Discrete Lengths This option sets the unit to decode only those codes containing two selected lengths For example select Codabar Two Discrete Lengths then scan O 2 1 4 to decode only Codabar symbols containing 6 or 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 Codabar Two Discrete Lengths Length Within Range Select this option to decode a code within a specified range For example to decode Codabar symbols containing between 4 and 12 characters first scan
2. UPC EAN Security Level 1 As bar code quality levels diminish certain characters become prone to mis decodes before others i e 1 2 7 8 If mis decodes of poorly printed bar codes occur and the mis decodes are limited to these characters select this security level UPC EAN Security Level 1 01h UPC EAN Security Level 2 If mis decodes of poorly printed bar codes occur and the mis decodes are not limited to characters 1 2 7 and 8 select this security level UPC EAN Security Level 2 02h UPC EAN Security Level 3 If misdecodes still occur after selecting Security Level 2 select this security level Be advised selecting this option is an extreme measure against mis decoding severely out of spec bar codes Selection of this level of security significantly impairs the decoding ability of the scan engine If this level of UPC EAN Security Level 3 03h security is necessary try to improve the quality of the bar codes 20 Barcode scanner configuration guide UCC Coupon Extended Code Parameter 55h The UCC Coupon Extended Code is an additional bar code adjacent to a UCC Coupon Code To enable or disable UCC Coupon Extended Code Enable UCC Coupon Extended Code 01h Disable UCC Coupon Extended Code 00h scan the appropriate bar code below Barcode scanner configuration guide Coupon Report Parameter F1h DAh Traditional coupon symbols old coupon symbols are composed of two bar codes UPC EA
3. f you select Enable ISBT Concatenation there must be two ISBT codes in order for the digital scanner to decode and perform concatenation The digital scanner does not decode single ISBT symbols f you select Autodiscriminate ISBT Concatenation the digital scanner decodes and concatenates pairs of ISBT codes immediately If only a single SBT symbol is present the digital scanner must decode the symbol the number of times set via ISBT Concatenation Redundancy before transmitting its data to confirm that there is no additional ISBT symbol Disable ISBT Concatenation 00h Enable ISBT Concatenation 01h Autodiscriminate ISBT Concatenation 00h Check ISBT Table Parameter F1h 42h The ISBT specification includes a table that lists several types of ISBT bar codes that are commonly used in pairs If you set ISBT Concatenation to Enable enable Check ISBT Table to concatenate only those pairs found in this table Other types of ISBT codes are not concatenated Enable Check ISBT Table 01h Disable Check ISBT Table 00h Barcode scanner configuration guide 27 ISBT Concatenation Redundancy Parameter DFh If you set ISBT Concatenation to Autodiscriminate use this parameter to set the number of times the digital scanner must decode an ISBT symbol before determining that there is no additional symbol Scan the bar code below then scan two numeric bar codes in Numeric Bar Codes on page 56 to set a value
4. Scan this symbol to transmit data without the check digit Do Not Transmit Code 39 Check Digit Disable 00h 32 Barcode scanner configuration guide Enable Disable Code 39 Full ASCII Parameter 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set To enable or disable Code 39 Full ASCII scan Enable Code 39 Full ASCII 00h Disable Code 39 Full ASCII 00h the appropriate bar code below NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously If the Enable Trioptic Code 39 setting is not accepted disable Code 39 Full ASCII and try again An SSI parameter entry error event ID 07h is sent to the host if packeted data communication is enabled to inform the user that the parameter change was not accepted Barcode scanner configuration guide 33 6 Code 93 Enable Disable Code 93 Parameter 09h To enable or disable Code 93 scan the appropriate bar code below Enable Code 93 01h Disable Code 93 00h 34 Barcode scanner configuration guide Set Lengths for Code 93 Parameter L1 1Ah L2 1Bh The length of a code refers to the number of characters i e human readable characters including check digit s the code contains Lengths for Code 93 may be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length Select this option to decode only those codes contain
5. Select this option to decode a Code 128 symbol with a specific length range Select lengths using numeric bar codes beginning on page 56 For example to decode Code 128 symbols containing between 4 and 12 characters first scan Code 128 Length Within Range Then scan 0 4 1 and 2 enter a leading zero for single digit numbers To correct an error or change the selection scan Cancel on page 57 Any Length Select this option to decode Code 128 symbols containing any number of characters within the digital scanner s capability Code 128 One Discrete Length Code 128 Two Discrete Lengths Code 128 Length Within Range Code 128 Any Length Barcode scanner configuration guide 25 Enable Disable GS1 128 formerly UCC EAN 128 Parameter OEh To enable or disable GS1 128 scan the appropriate bar code below See Appendix A Miscellaneous Code Information for details on GS1 128 formerly UCC EAN 128 Enable GS1 128 01h Disable GS1 128 00h Enable Disable ISBT 128 Parameter 54h To enable or disable ISBT 128 scan the appropriate bar code below Enable ISBT 128 01h Disable ISBT 128 00h 26 Barcode scanner configuration guide ISBT Concatenation Parameter F1h 41h Select an option for concatenating pairs of ISBT code types f you select Disable ISBT Concatenation the digital scanner does not concatenate pairs of ISBT codes it encounters
6. Select this option to decode only those codes containing a selected length For example select MSI One Discrete Length then scan 1 4 to decode only MSI symbols containing 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect MSI One Discrete Length entry scan Cancel on page 57 Two Discrete Lengths Select this option to decode only those codes containing two selected lengths For example select MSI Two Discrete Lengths then scan 0 6 1 4 to decode only MSI symbols containing 6 or 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 MSI Two Discrete Lengths Length Within Range Select this option to decode codes within a specified range For example to decode MSI symbols containing between 4 and 12 characters first scan MSI Length Within Range then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 MSI Two Discrete Lengths Any Length Scan this option to decode MSI Plessey symbols containing any number of characters Barcode scanner configuration guide 51 NOTE Selecting this option may lead to misdecodes for MSI codes MSI Any Length MSI Check Digits Parameter 32h These check digits at the end of the bar code verify the integrity
7. Digit F1h 6Fh Disable Inverse 1D Inverse 1D F1h 4Ah Regular Codabar Codabar 07h Disable Set Lengths for Codabar 18h 5 55 19h CLSI Editing 36h Disable NOTIS Editing 37h Disable MS MS OBh Disable Set Length s for MSI 1Eh 6 55 1Fh MSI Check Digits 32h One Transmit MS Check Digit 2Eh Disable MSI Check Digit Algorithm 33h Mod 10 Mod 10 GS1 DataBar GS1 DataBar Omnidirectional FOh 52h Enable GS1 DataBar Limited FOh 53h Enable GS1 DataBar Expanded FOh 54h Enable Convert GS1 DataBar to UPC EAN FOh Disable 8Dh Barcode scanner configuration guide 2 Set default parameter Scan Set Factory Defaults to restore the factory default values listed in the table on page 5 Set Factory Defaults Barcode scanner configuration guide 3 UPC EAN Enable Disable UPC A Parameter 01h To enable or disable UPC A scan the appropriate bar code below Enable UPC A 01h Disable UPC A 00h Enable Disable UPC E Parameter 02h To enable or disable UPC E scan the appropriate bar code below Enable UPC E 01h Disable UPC E 00h Barcode scanner configuration guide Enable Disable UPC E1 Parameter OCh To enable or disable UPC E1 scan the appropriate bar code below NOTE UPC E1 is not a UCC Uniform Code Council approved symbology Enable UPC E1 01h Disable UPC E1 00h Enable Disable EAN 8 Parameter 04h To enable or disable EAN 8
8. Digit Verification Transmit Code 11 Check Digits 8 Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Set Lengths for Interleaved 2 of 5 1 2 of 5 Check Digit Verification Transmit 2 of 5 Check Digit Convert 2 of 5 to EAN 13 9 Discrete 2 of 5 Enable Disable Discrete 2 of 5 Set Lengths for Discrete 2 of 5 10 Chinese 2 of 5 Enable Disable Chinese 2 of 5 11 Matrix 2 of 5 Enable Disable Matrix 2 of 5 Set Lengths for Matrix 2 of 5 Matrix 2 of 5 Redundancy Matrix 2 of 5 Check Digit Transmit Matrix 2 of 5 Check Digit 12 Inverse 1D 13 Codabar Enable Disable Codabar Set Lengths for Codabar CLSI Editing NOTIS Editing 14 MSI Enable Disable MSI Set Lengths for MSI MSI Check Digits Transmit MSI Check Digit MSI Check Digit Algorithm 15 GS1 DataBar Enable Disable GS1 DataBar Omnidirectional Enable Disable GS1 DataBar Limited Enable Disable GS1 DataBar Expanded Convert GS1 DataBar to UPC EAN 16 Numeric Bar Codes Cancel Barcode scanner configuration guide 1 Introduction This booklet describes the programmable parameters and provides bar codes for programming the Pocket Memo dictation recorder with barcode scanner Operational Parameters The Pocket Memo dictation recorder with barcode scanner is shipped with the factory default settings shown in the table below These factory default values are stored in non volatile memory and are preserved even when the scanner is powered down To change the paramet
9. ISBT Concatenation F1h 41h Disable Check ISBT Table F1h 42h Enable ISBT Concatenation Redundancy DFh 10 Code 39 Code 39 00h Enable Trioptic Code 39 ODh Disable Convert Code 39 to Code 32 56h Disable Barcode scanner configuration guide 5 Parameter Parameter no Hex Factory default Code 32 Prefix E h Disable Set Length s for Code 39 2h 2 55 3h Code 39 Check Digit Verification 30h Disable Transmit Code 39 Check Digit 2Bh Disable Code 39 Full ASCII Conversion 1h Disable Code 93 Code 93 09h Disable Set Length s for Code 93 Ah 4 55 Bh Code 11 Code 11 OAh Disable Set Lengths for Code 11 Ch 4to 55 Dh Code 11 Check Digit Verification 34h Disable Transmit Code 11 Check Digit s 2Fh Disable Interleaved 2 of 5 Interleaved 2 of 5 06h Enable Set Length s for 2 of 5 16h 14 17h 2 of 5 Check Digit Verification 31h Disable Transmit 2 of 5 Check Digit 2Ch Disable Convert 2 of 5 to EAN 13 52h Disable Discrete 2 of 5 Discrete 2 of 5 05h Disable Set Length s for D 2 of 5 14h 12 15h Chinese 2 of 5 Chinese 2 of 5 FOh 98h Disable Matrix 2 of 5 Matrix 2 of 5 F1h 6Ah Disable Matrix 2 of 5 Lengths F1h 6Bh 14 F1h 6Ch Matrix 2 of 5 Redundancy F1h 6Dh Disable Matrix 2 of 5 Check Digit F1h 6Eh Disable Transmit Matrix 2 of 5 Check
10. scan the appropriate bar code below Enable EAN 8 01h Disable EAN 8 00h Barcode scanner configuration guide Enable Disable EAN 13 Parameter 03h To enable or disable EAN 13 scan the appropriate bar code below Enable EAN 13 01h Disable EAN 13 00h Enable Disable Bookland EAN Parameter h53h To enable or disable EAN Bookland scan the appropriate bar code below Enable Bookland EAN 01h Disable Bookland EAN 00h NOTE If you enable Bookland EAN select a Bookland ISBN Format Also select either Decode UPC EAN Supplementals Autodiscriminate UPC EAN Supplementals or Enable 978 979 Supplemental Mode in Decode UPC EAN Supplementals 10 Barcode scanner configuration guide Bookland ISBN Format Parameter F1h 40h If Bookland EAN is enabled select one of the following formats for Bookland data Bookland ISBN 10 The digital scanner reports Bookland data starting with 978 in traditional 10 digit format with the special Bookland check digit for backward compatibility Data starting with 979 is not considered Bookland in this mode Bookland ISBN 13 The digital scanner reports Bookland data starting with either 978 or 979 as EAN 13 in 13 digit format to meet the 2007 ISBN 13 protocol Bookland ISBN 10 00h Bookland ISBN 13 01h NOTE For Bookland EAN to function properly ensure Bookland EAN is enabled see Enable Disable Bookland EAN then select either Decode UPC EAN S
11. single digit numbers must always be preceded by a leading zero To correct an error or change the selection scan Cancel on page 57 Any Length Scan this option to decode Code 11 symbols containing any number of characters within the scan engine capability Code 11 One Discrete Length Code 11 Two Discrete Lengths Code 11 Length Within Range Code 11 Any Length Barcode scanner configuration guide 37 Code 11 Check Digit Verification Parameter 34h This feature allows the scan engine to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm This selects the check digit mechanism for the decoded Code 11 bar code The options are to check for one check digit check for two check digits or disable the feature To enable this feature scan the bar code below corresponding to the number of check digits encoded in your Code 11 symbols Disable 00h One Check Digit 01h Two Check Digits 02h Transmit Code 11 Check Digits Parameter 2Fh This feature selects whether or not to transmit the Code 11 check digit s Transmit Code 11 Check Digit s Enable 01h Do Not Transmit Code 11 Check Digit s Disable 00h NOTE Code 11 Check Digit Verification must be enabled for this parameter to function 38 Barcode scanner configuration guide 8 Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Parameter 06h To ena
12. Codabar Length Within Range then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 Codabar Length Within Range Any Length Scan this option to decode Codabar symbols containing any number of characters Barcode scanner configuration guide 49 Codabar Any Length CLSI Editing Parameter 36h When enabled this parameter strips the start and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol NOTE Symbol length does not include start and stop characters Enable CLSI Editing 01h Disable CLSI Editing 00h NOTIS Editing Parameter 37h When enabled this parameter strips the start and stop characters from decoded Codabar symbol Enable NOTIS Editing 01h Disable NOTIS Editing 00h 50 Barcode scanner configuration guide 14 MSI Enable Disable MSI Parameter OBh To enable or disable MSI scan the appropriate bar code below Enable MSI 01h Disable MSI 00h Set Lengths for MSI Parameter L1 1Eh L2 1Fh The length of a code refers to the number of characters i e human readable characters the code contains and includes check digits Lengths for MSI can be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length
13. Code 39 to Code 32 01h Disable Convert Code 39 to Code 32 00h Code 32 Prefix Parameter E7h Enable this parameter to add the prefix character A to all Code 32 bar codes Convert Code 39 to Code 32 Italian Pharma Code must be enabled for this parameter to function Enable Code 32 Prefix 01h Disable Code 32 Prefix 00h 30 Barcode scanner configuration guide Set Lengths for Code 39 Parameter L1 12h L2 13h The length of a code refers to the number of characters i e human readable characters including check digit s the code contains Lengths for Code 39 may be set for any length one or two discrete lengths or lengths within a specific range If Code 39 Full ASCII is enabled Length Within a Range or Any Length are the preferred options NOTE When setting lengths single digit numbers must always be preceded by a leading zero One Discrete Length This option limits decodes to only those Code 39 symbols containing a selected length Lengths are selected from the numeric bar codes beginning on page 56 For example to decode only Code 39 symbols with 14 characters scan Code 39 One Discrete Length then scan 1 followed by 4 To change the selection or cancel an incorrect entry scan Cancel Code 39 One Discrete Length Two Discrete Lengths This option limits decodes to only those Code 39 symbols containing either of two selected lengths Lengths are selected from the numeric bar
14. N and Code128 A new coupon symbol is composed of a single Databar Expanded bar code The new coupon format offers more options for purchase values up to 999 99 and supports complex discount offers such as a second purchase requirement An interim coupon symbol also exists that contains both types of bar codes UPC EAN and Databar Expanded This format accommodates both retailers that do not recognize or use the additional information included in the new coupon symbol as well as those who can process new coupon symbols Scan a bar code below to select one of the following options for decoding coupon symbols Old Coupon Symbols Scanning an old coupon symbol reports both UPC and Code 128 scanning an interim coupon symbol reports UPC and scanning a new coupon symbol reports nothing no decode New Coupon Symbols Scanning an old coupon symbol reports either UPC or Code 128 and scanning an interim coupon symbol or a new coupon symbol reports Databar Expanded Both Coupon Formats Scanning an old coupon symbol reports both UPC and Code 128 and scanning an interim coupon symbol or a new coupon Old Coupon Symbols 00h New Coupon Symbols 01h Both Coupon Formats 02h symbol reports Databar Expanded 22 Barcode scanner configuration guide ISSN EAN Parameter F1h 69h To enable or disable ISSN EAN scan the appropriate bar code below Enable ISSN EAN 01h Disable ISSN EAN 00h Barcode scanne
15. PC A Check Digit 01h Do Not Transmit UPC A Check Digit 00h 14 Barcode scanner configuration guide Transmit UPC E Check Digit Parameter 29h Scan the appropriate bar code below to transmit the symbol with or without the UPC E check digit Transmit UPC E Check Digit 01h Do Not Transmit UPC E Check Digit 00h Transmit UPC E1 Check Digit Parameter 2Ah Scan the appropriate bar code below to transmit the symbol with or without the UPC E1 check digit Transmit UPC E1 Check Digit 01h Do Not Transmit UPC E1 Check Digit 00h Barcode scanner configuration guide 15 UPC A Preamble Parameter 22h Preamble characters Country Code and System Character can be transmitted as part of a UPC A symbol Select one of the following options for transmitting UPC A preamble to the host device transmit system character only transmit system character and country code O for USA or No Preamble lt DATA gt 00h System Character SYSTEM CHARACTER lt DATA gt 01h System Character amp Country Code lt COUNTRY CODE SYSTEM CHARACTER lt DATA gt 02h transmit no preamble 16 Barcode scanner configuration guide UPC E Preamble Parameter 23h Preamble characters Country Code and System Character can be transmitted as part of a UPC E symbol Select one of the following options for transmitting UPC E preamble
16. Register your product and get support at PO C K ET M M Q www philips com dictation DPM8500 Barcode scanner configuration guide PHILIPS Table of contents 1 Introduction Operational Parameters Parameter defaults 2 Set default parameter 3 UPC EAN Enable Disable UPC A Enable Disable UPC E Enable Disable UPC E1 Enable Disable EAN 8 Enable Disable EAN 13 Enable Disable Bookland EAN Bookland ISBN Format Decode UPC EAN Supplementals Decode UPC EAN Supplemental Redundancy UPC EAN JAN Supplemental AIM ID Format Transmit UPC A Check Digit Transmit UPC E Check Digit Transmit UPC E1 Check Digit UPC A Preamble UPC E Preamble UPC E1 Preamble Convert UPC E to UPC A Convert UPC E1 to UPC A EAN Zero Extend UPC EAN Security Level UCC Coupon Extended Code Coupon Report ISSN EAN 4 Code 128 Enable Disable Code 128 Set Lengths for Code 128 Enable Disable GS1 128 formerly UCC EAN 128 Enable Disable ISBT 128 ISBT Concatenation Check ISBT Table ISBT Concatenation Redundancy 5 Code 39 Enable Disable Code 39 Enable Disable Trioptic Code 39 Convert Code 39 to Code 32 Italian Pharma Code Code 32 Prefix Set Lengths for Code 39 Code 39 Check Digit Verification Transmit Code 39 Check Digit Enable Disable Code 39 Full ASCII 6 Code 93 Enable Disable Code 93 Set Lengths for Code 93 Barcode scanner configuration guide Un Ui Cr 7 Code 11 Enable Disable Code 11 Set Lengths for Code 11 Code 11 Check
17. between 2 and 20 Enter a leading zero for single digit numbers To correct an error or change a selection scan Cancel on page 57 The default is 10 ISBT Concatenation Redundancy 28 Barcode scanner configuration guide 5 Code 39 Enable Disable Code 39 Parameter 00h To enable or disable Code 39 scan the appropriate bar code below Enable Code 39 01h Disable Code 39 00h Enable Disable Trioptic Code 39 Parameter ODh Trioptic Code 39 is a variant of Code 39 used in marking computer tape cartridges Trioptic Code 39 symbols always contain six characters To enable or disable Trioptic Code 39 scan the appropriate bar code below Enable Trioptic Code 39 01h Disable Trioptic Code 39 00h NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously If the Enable Trioptic Code 39 setting is not accepted disable Code 39 Full ASCII and try again An SSI parameter entry error event ID O7h is sent to the host if packeted data communication is enabled to inform the user that the parameter change was not accepted Barcode scanner configuration guide 29 Convert Code 39 to Code 32 Italian Pharma Code Parameter 56h Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 NOTE Code 39 must be enabled in order for this parameter to function Enable Convert
18. ble or disable Interleaved 2 of 5 scan the appropriate bar code below Enable Interleaved 2 of 5 01h Disable Interleaved 2 of 5 Set Lengths for Interleaved 2 of 5 Parameter L1 16h L2 17h The length of a code refers to the number of characters i e human readable characters including check digit s the code contains Lengths for 2 of 5 may be set for any length one or two discrete lengths or lengths within a specific range NOTE When setting lengths single digit numbers must always be preceded by a leading zero One Discrete Length Select this option to decode only those codes containing a selected length For example select 2 of 5 One Discrete Length then scan 1 4 to decode only 2 of 5 symbols containing 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 2 of 5 One Discrete Length Two Discrete Lengths Select this option to decode only those codes containing two selected lengths For example select 2 of 5 Two Discrete Lengths then scan O 6 1 4 to decode only 2 of 5 symbols containing 6 or 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 2 of 5 Two Discrete Lengths Barcode scanner configuration guide 39 Length Within Range Select this option to decode only codes within a specified range For example to decode 2 of 5 symbols
19. codes beginning on page 56 For example to decode only those Code 39 symbols containing either 2 or 14 characters select Code 39 Two Discrete Lengths then scan O 2 1 and then 4 To change the selection or cancel an incorrect entry scan Cancel on page 57 Code 39 Two Discrete Lengths Length Within Range This option limits decodes to only those Code 39 symbols within a specified range For example to decode Code 39 symbols containing between 4 and 12 characters first scan Code 39 Length Within Range Then scan O0 4 1 and 2 Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 Code 39 Length Within Range Any Length Scan this option to decode Code 39 symbols containing any number of characters Code 39 Any Length Barcode scanner configuration guide 31 Code 39 Check Digit Verification Parameter 30h When this feature is enabled the scan engine checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm Only those Code 39 symbols which include a modulo 43 check digit are decoded Only enable this feature if your Code 39 symbols contain Verify Code 39 Check Digit 01h Do Not Verify Code 39 Check Digit 00h a module 43 check digit Transmit Code 39 Check Digit Parameter 2Bh Scan this symbol to transmit the check digit with the data Transmit Code 39 Check Digit Enable 01h
20. containing between 4 and 12 characters first scan 2 of 5 Length Within Range then scan O 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 12 of 5 Length Within Range Any Length Scan this option to decode 2 of 5 symbols containing any number of characters NOTE Selecting this option may lead to misdecodes for 2 of 5 codes 12 of 5 Any Length 2 of 5 Check Digit Verification Parameter 31h When enabled this parameter checks the integrity of an 2 of 5 symbol to ensure it complies with a specified algorithm either USS Uniform Symbology Specification or OPCC Optical Product Code Council Disable 00h USS Check Digit 01h OPCC Check Digit 02h 40 Barcode scanner configuration guide Transmit 2 of 5 Check Digit Parameter 2Ch Scan this symbol to transmit the check digit with the data Transmit 2 of 5 Check Digit Enable 01h Do Not Transmit 2 of 5 Check Digit Disable 00h Scan this symbol to transmit data without the check digit Convert 2 of 5 to EAN 13 Parameter 52h This parameter converts a 14 character 2 of 5 code into EAN 13 and transmits to the host as EAN 13 To accomplish this 2 of 5 must be enabled one length must be set to 14 and the code must have a leading zero and a valid EAN 13 check digit Convert I 2
21. e that prefix immediately Enable 378 379 Supplemental Mode Enable 978 979 Supplemental Mode NOTE If you select 978 979 Supplemental Mode and are scanning Bookland EAN bar codes see Enable Disable Bookland EAN to enable Bookland EAN and select a format using Bookland ISBN Format Enable 977 Supplemental Mode Enable 414 419 434 439 Supplemental Mode Enable 491 Supplemental Mode Enable Smart Supplemental Mode applies to EAN 13 bar codes starting with any prefix listed previously NOTE To minimize the risk of invalid data transmission select either to decode or ignore supplemental characters Barcode scanner configuration guide 11 Select the desired option by scanning one of the following bar codes Decode UPC EAN With Supplementals 01h Ignore UPC EAN With Supplementals 00h Autodiscriminate UPC EAN Supplementals 02h Enable 378 379 Supplemental Mode 04h Enable 978 979 Supplemental Mode 05h 12 Barcode scanner configuration guide Enable 977 Supplemental Mode 07h Enable 414 419 434 439 Supplemental Mode 06h Enable 491 Supplemental Mode 08h Enable Smart Supplemental Mode 03h Decode UPC EAN Supplemental Redundancy Parameter 50h With Autodiscriminate UPC EAN Supplementals selected this option adjusts the number of times a symbol without s
22. emblem are registered trademarks of Koninklijke Philips Electronics N V and are used by Speech Processing Solutions GmbH under license from Koninklijke Philips Electronics N V All trademarks are the property of their respective owners Document version 1 0 2013 04 10
23. er values Scan the appropriate bar codes included in this chapter pprop P L The new values replace the existing memory values 2 The factory default values can be recalled by scanning the RESTORE DEFAULTS bar code on page 7 Parameter defaults The table lists the factory defaults for all parameters To change any option scan the appropriate bar code s Parameter Parameter no Hex Factory default Set Factory Default All Defaults UPC EAN UPC A 01h Enable UPC E 02h Enable UPC E1 OCh Disable EAN 8 04h Enable EAN 13 03h Enable Bookland EAN 53h Disable Bookland ISBN Format F1h 40h SBN 10 Decode UPC EAN Supplementals 10h gnore Decode UPC EAN Supplemental Redundancy 50h 7 UPC EAN JAN Supplemental AIM ID Format F1h AOh Combined Transmit UPC A Check Digit 28h Enable Transmit UPC E Check Digit 29h Enable Transmit UPC E1 Check Digit 2Ah Enable UPC A Preamble 22h System Character UPC E Preamble 23h System Character UPC E1 Preamble 24h System Character Convert UPC E to A 25h Disable Convert UPC E1 to A 26h Disable EAN 8 Zero Extend 27h Disable UPC EAN Security Level 4Dh 1 UCC Coupon Extended Code 55h Disable Coupon Report F1h DAh Both Coupon Formats ISSN EAN F1h 69h Disable Code 128 Code 128 08h Enable Set Length s for Code 128 D1h 1 55 D2h GS1 128 formerly UCC EAN 128 OEh Enable ISBT 128 54h Enable
24. ing a selected length For example select Code 93 One Discrete Length then scan 1 4 to limit the decoding to only Code 93 symbols containing 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 Code 93 One Discrete Length Two Discrete Lengths Select this option to decode only those codes containing two selected lengths For example select Code 93 Two Discrete Lengths then scan 0 2 1 4 to limit the decoding to only Code 93 symbols containing 2 or 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 Code 93 Two Discrete Lengths Length Within Range This option sets the unit to decode a code type within a specified range For example to decode Code 93 symbols containing between 4 and 12 characters first scan Code 93 Length Within Range then scan O 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 Code 93 Length Within Range Any Length Scan this option to decode Code 93 symbols containing any number of characters Code 93 Any Length Barcode scanner configuration guide 35 7 Code 11 Enable Disable Code 11 Parameter OAh To enable or disable Code 11 scan the appropriate bar code below Enable Code 11 01h D
25. isable Code 11 00h 36 Barcode scanner configuration guide Set Lengths for Code 11 Parameter 4 L1 1Ch L2 1Dh The len Code 1 One gth of a code refers to the number of characters i e human readable characters including check digit s the code contains Set lengths for 1 to any length one or two discrete lengths or lengths within a specific range Discrete Length Select this option to decode only Code 11 symbols containing a selected length Select the length using the numeric bar codes beginning on page 56 For example to decode only Code 11 symbols with 14 characters scan Code 11 One Discrete Length then scan 1 followed by 4 To correct an error or to change the selection scan Cancel on page 57 wo Discrete Lengths Select this option to decode only Code 11 symbols containing either of two selected lengths Select lengths using the numeric bar codes beginning on page 56 For example to decode only those Code 11 symbols containing either 2 or 14 characters select Code 11 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page 57 Length Within Range Select this option to decode a Code 11 symbol with a specific length range Select lengths using numeric bar codes beginning on page 56 For example to decode Code 11 symbols containing between 4 and 12 characters first scan Code 11 Length Within Range Then scan 0 4 1 and 2
26. ithin Range Select this option to decode codes within a specified range For example to decode D 2 of 5 symbols containing between 4 and 12 characters first scan D 2 of 5 Length Within Range then scan 0 4 1 and 2 single digit numbers must be preceded by a leading zero Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 D 2 of 5 Length Within Range Any Length Scan this option to decode D 2 of 5 symbols containing any number of characters 42 Barcode scanner configuration guide NOTE Selecting this option may lead to misdecodes for D 2 of 5 codes D 2 of 5 Any Length Barcode scanner configuration guide 43 10 Chinese 2 of 5 Enable Disable Chinese 2 of 5 Parameter FOh 98h To enable or disable Chinese 2 of 5 scan the appropriate bar code below Enable Chinese 2 of 5 01h Disable Chinese 2 of 5 00h 44 Barcode scanner configuration guide 11 Matrix 2 of 5 Enable Disable Matrix 2 of 5 Parameter F1h 6Ah To enable or disable Matrix 2 of 5 scan the appropriate bar code below Enable Matrix 2 of 5 01h Disable Matrix 2 of 5 00h Barcode scanner configuration guide 45 Set Lengths for Matrix 2 of 5 Parameter L1 F1h 6Bh L2 F1h 6Ch The length of a code refers to the number of characters i e human readable characters including check digit s the code contains Set lengths for Matrix 2 of 5 to any le
27. ner s capability Matrix 2 of 5 One Discrete Length Matrix 2 of 5 Two Discrete Lengths Matrix 2 of 5 Length Within Range Matrix 2 of 5 Any Length 46 Barcode scanner configuration guide Matrix 2 of 5 Redundancy Parameter F1h 6Dh To enable or disable Matrix 2 of 5 redundancy scan the appropriate bar code below Enable Matrix 2 of 5 Redundancy 01h Disable Matrix 2 of 5 Redundancy 00h Matrix 2 of 5 Check Digit Parameter F1h 6Eh The check digit is the last character of the symbol used to verify the integrity of the data Scan the appropriate bar code below to transmit the bar Enable Matrix 2 of 5 Check Digit 01h Disable Matrix 2 of 5 Check Digit 00h code data with or without the Matrix 2 of 5 check digit Transmit Matrix 2 of 5 Check Digit Parameter F1h 6Fh Scan a bar code below to transmit Matrix 2 of 5 data with or without the check digit Transmit Matrix 2 of 5 Check Digit 01h Do Not Transmit Matrix 2 of 5 Check Digit 00h Barcode scanner configuration guide 47 12 Inverse 1D Parameter F1h 4Ah This parameter sets the 1D inverse decoder setting Options are Regular Only the digital scanner decodes regular 1D bar codes only Inverse Only the digital scanner decodes inverse 1D bar codes only Inverse Autodetect the digital scanner decodes both regular and inverse 1D bar codes Regular 00h Inverse Only 01h Inverse Autodetect 02h
28. ngth one or two discrete lengths or lengths within a specific range One Discrete Length Select this option to decode only Matrix 2 of 5 symbols containing a selected length Select the length using the numeric bar codes beginning on page 56 For example to decode only Matrix 2 of 5 symbols with 14 characters scan then scan 1 followed by 4 To correct an error or to change the selection scan Cancel on page 57 atrix 2 of 5 One Discrete Length wo Discrete Lengths Select this option to decode only Matrix 2 of 5 symbols containing either of two selected lengths Select lengths using the numeric bar codes beginning on page 56 For example to decode only Matrix 2 of 5 symbols containing either 2 or 14 characters select Matrix 2 of 5 Two Discrete Lengths then scan O 2 1 and then 4 To correct an error or to change the selection scan Cancel on page 57 Length Within Range Select this option to decode a Matrix 2 of 5 symbol with a specific length range Sel ect lengths using the numeric bar codes beginning on page 56 For example to decode Matrix 2 of 5 symbols containing between 4 and 12 characters first scan Matrix 2 of 5 Length Within Range Then scan 0 4 1 and 2 enter a leading zero for single digit numbers To correct an error or change the selection scan Cancel on page 57 Any Length Scan this option to decode Matrix 2 of 5 symbols containing any number of characters within the digital scan
29. of 5 to EAN 13 Enable 01h Do Not Convert I 2 of 5 to EAN 13 Disable 00h Barcode scanner configuration guide 41 9 Discrete 2 of 5 Enable Disable Discrete 2 of 5 Parameter 05h To enable or disable Discrete 2 of 5 scan the appropriate bar code below Enable Discrete 2 of 5 01h Disable Discrete 2 of 5 00h Set Lengths for Discrete 2 of 5 Parameter L1 14h L2 15h The length of a code refers to the number of characters i e human readable characters including check digit s the code contains Lengths for D 2 of 5 may be set for any length one or two discrete lengths or lengths within a specific range One Discrete Length Select this option to decode only those codes containing a selected length For example select D 2 of 5 One Discrete Length then scan 1 4 to decode only D 2 of 5 symbols containing 14 characters Numeric bar codes begin on page 56 To change the selection or cancel D 2 of 5 One Discrete Length an incorrect entry scan Cancel on page 57 Two Discrete Lengths Select this option to decode only those codes containing two selected lengths For example select D 2 of 5 Two Discrete Lengths then scan O 2 1 4 to decode only D 2 of 5 symbols containing 2 or 14 characters Numeric bar codes begin on page 56 To change the selection or cancel an incorrect entry scan Cancel on page 57 D 2 of 5 Two Discrete Lengths Length W
30. of the data At least one check digit is always required Check digits are not One MSI Check Digit 00h automatically transmitted with the data If two check digits are selected also select an MSI Check Digit Algorithm Two MSI Check Digit 01h Transmit MSI Check Digit Parameter 2Eh Scan this symbol to transmit the check digit with the data Transmit MSI Check Digit Enable 01h Do Not Transmit MSI Check Digit Disable 00h Scan this symbol to transmit data without the check digit 52 Barcode scanner configuration guide MSI Check Digit Algorithm Parameter 33h When the Two MSI check digits option is selected an additional verification is required to ensure integrity Select one of the following algorithms MOD 10 MOD 11 00h MOD 10 MOD 10 01h Barcode scanner configuration guide 53 15 GS1 DataBar Enable Disable GS1 DataBar Omnidirectional Parameter FOh 52h To enable or disable GS1 DataBar Omnidirectional scan the appropriate bar code below Enable GS1 DataBar Omnidirectional 01h Disable GS1 DataBar Omnidirectional 00h Enable Disable GS1 DataBar Limited Parameter FOh 53h To enable or disable GS1 DataBar Limited scan the appropriate bar code below Enable GS1 DataBar Limited 01h Disable GS1 DataBar Limited 00h 54 Barcode scanner configuration guide Enable Disable GS1 DataBar Expanded Parameter FOh 54h To enable or disable GS1 Da
31. r configuration guide 23 4 Code 128 Enable Disable Code 128 Parameter 08h To enable or disable Code 128 scan the appropriate bar code below Enable Code 128 01h Disable Code 128 00h 24 Barcode scanner configuration guide Set Lengths for Code 128 Parameter L1 D1h L2 D2h The length of a code refers to the number of characters i e human readable characters including check digit s the code contains Set lengths for Code 128 to any length one or two discrete lengths or lengths within a specific range NOTE When setting lengths for different bar code types enter a leading zero for single digit numbers One Discrete Length Select this option to decode only Code 128 symbols containing a selected length Select the length using the numeric bar codes beginning on page 56 For example to decode only Code 128 symbols with 14 characters scan Code 128 One Discrete Length then scan 1 followed by 4 To correct an error or change the selection scan Cancel on page 57 Two Discrete Lengths Select this option to decode only Code 128 symbols containing either of two selected lengths Select lengths using the numeric bar codes beginning on page 56 For example to decode only Code 128 symbols containing either 2 or 14 characters select Code 128 Two Discrete Lengths then scan O 2 1 and then 4 To correct an error or change the selection scan Cancel on page 57 Length Within Range
32. rcode scanner configuration guide Convert UPC E1 to UPC A Parameter 26h Enable this parameter to convert UPC E1 zero suppressed decoded data to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit Scan DO NOT CONVERT UPC E TO UPC A to transmit UPC E1 zero suppressed decoded data Convert UPC E1 to UPC A Enable 01h Do Not Convert UPC E1 to UPC A Disable 00h EAN Zero Extend Parameter 27h When enabled this parameter adds five leading zeros to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Enable EAN Zero Extend 01h Disable EAN Zero Extend 00h Disable this parameter to transmit EAN 8 symbols as is Barcode scanner configuration guide 19 UPC EAN Security Level Parameter 4Dh The scanner offers four levels of decode security for UPC EAN bar codes Increasing levels of security are provided for decreasing levels of bar code quality Select higher levels of security for decreasing levels of bar code quality Increasing security decreases the scan engine s aggressiveness so choose only that level of security necessary for the application UPC EAN Security Level 0 This default setting allows the scan engine to operate in its most aggressive state while providing sufficient security in decoding most in spec UPC EAN bar codes UPC EAN Security Level 0 00h
33. taBar Expanded scan the appropriate bar code below Enable GS1 DataBar Expanded 01h Disable GS1 DataBar Expanded 00h Convert GS1 DataBar to UPC EAN Parameter FOh 8Dh This parameter only applies to GS1 DataBar Omnidirectional and GS1 DataBar Limited symbols When this conversion is enabled GS1 DataBar Omnidirectional and GS1 DataBar Limited symbols encoding a single zero as the first digit have the leading 010 stripped and the bar code reported as EAN 13 Bar codes beginning with two or more zeros but not six zeros have the leading 0100 stripped and the bar code reported as UPC A The UPC A Preamble parameter to transmit the system character and country code applies to converted bar codes Note that neither the system character nor Enable Convert GS1 DataBar to UPC EAN Disable Convert GS1 DataBar to UPC EAN the check digit can be stripped Barcode scanner configuration guide 55 16 Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 56 0 AMI 1 A 2 ANI 3 MACNN 4 AM 5 Barcode scanner configuration guide 6 D 7 M 8 TIL 9 Cancel To change the selection or cancel an incorrect entry scan the bar code below Barcode scanner configuration guide Cancel 57 PHILIPS Specifications are subject to change without notice 2013 Speech Processing Solutions GmbH All rights reserved Philips and the Philips shield
34. to the host device transmit system character only transmit system character and country code 0 for USA or transmit no preamble No Preamble lt DATA gt 00h System Character lt SYSTEM CHARACTER lt DATA gt 01h System Character amp Country Code lt COUNTRY CODE gt SYSTEM CHARACTER gt lt DATA gt 02h Barcode scanner configuration guide 17 UPC E1 Preamble Parameter 24h Preamble characters Country Code and System Character can be transmitted as part of a UPC E1 symbol Select one of the following options for transmitting UPC E1 preamble to the host device transmit system character only transmit system character and country code 0 for USA or No Preamble DATA transmit no preamble 00h System Character SSYSTEM CHARACTER lt DATA gt 01h System Character amp Country Code lt COUNTRY CODE SYSTEM CHARACTER DATA 02h Convert UPC E to UPC A Parameter 25h Enable this parameter to convert UPC E zero suppressed decoded data to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit Scan DO NOT CONVERT UPC E TO UPC A to transmit UPC E zero suppressed decoded data Convert UPC E to UPC A Enable 01h Do Not Convert UPC E to UPC A Disable 00h 18 Ba
35. upplementals Autodiscriminate UPC EAN Supplementals or Enable 978 979 Supplemental Mode in Decode UPC EAN Supplementals Decode UPC EAN Supplementals Parameter 10h Supplementals are bar codes appended according to specific format conventions e g UPC A 2 UPC E 2 EAN 1342 The following options are available f you select Ignore UPC EAN with Supplementals and the scanner is presented with a UPC EAN plus supplemental symbol the scanner decodes UPC EAN and ignores the supplemental characters f you select Decode UPC EAN with Supplementals the scanner only decodes UPC EAN symbols with supplemental characters and ignores symbols without supplementals f you select Autodiscriminate UPC EAN Supplementals the scanner decodes UPC EAN symbols with supplemental characters immediately If the symbol does not have a supplemental the scanner must decode the bar code the number of times set via Decode UPC EAN Supplemental Redundancy before transmitting its data to confirm that there is no supplemental f you select one of the following Supplemental Mode options the scanner immediately transmits EAN 13 bar codes starting with that prefix that have supplemental characters If the symbol does not have a supplemental the scanner must decode the bar code the number of times set via Decode UPC EAN Supplemental Redundancy before transmitting its data to confirm that there is no supplemental The scanner transmits UPC EAN bar codes that do not hav
36. upplementals are decoded before transmission The range is from 2 to 20 times Five or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals and the autodiscriminate option is selected Scan the bar code below to select a decode redundancy value Next scan two numeric bar codes beginning on page 56 Single digit numbers must have a leading zero To change the selection or cancel an incorrect entry scan Cancel on page 54 Decode UPC EAN Supplemental Redundancy Default 7 Barcode scanner configuration guide 13 UPC EAN JAN Supplemental AIM ID Format Parameter F1h AOh Select an output format when reporting UPC EAN JAN bar codes with Supplementals with Transmit Code ID Character set to AIM Code ID Character Separate transmit UPC EAN with supplementals with separate AIM IDs but one transmission i e E 0 or 47 data E 1 or 2 gt supplemental data Combined transmit UPC EAN with supplementals with one AIM ID and one transmission i e E3 data supplemental data Separate Transmissions transmit UPC EAN with supplementals with separate AIM IDs and separate transmissions i e Separate 00h Combined 01h Separate Transmissions NEW END E 0 or 4 data E 1 or 2 supplemental data Transmit UPC A Check Digit Parameter 28h Scan the appropriate bar code below to transmit the symbol with or without the UPC A check digit Transmit U