GH20SB
Contents
1. Setting applied in more extensive schemes Setting applied only in scheme 14 Defines the maximum value measured by the T4 sensor for boiler pump control FROM 03 01 2012 GH20SB User Manual PAGE 24 Main pump collector pump adjustment If the collector pump adjustment is selected in the Controller settings the Controller will adjust the collector pump rotation speed If the collector pump speed adjustment Regulacja obrot w RegFaz pompy kolektor w Collector pump rotation speed adjustment Tryb pracy pompy cyrkulacyjnej Circulation pump operation mode Moc kolekt wy cz kot a grza ki pompy ciep a Collector power for deactivated boiler heater heat pump Ochrona przed ZabPrzeg przegrzaniem kolektor w Collector overheating prevention Max temp T2 Tsaxpisee wy cz ochrony przegrz kolektor w Max T2 temperature for deactivating collector overheating prevention Ochrona przed Przeciw Zam zamrozeniem kolektor w Collector freezing prevention Wyb r priorytetu PriorytAB grzania Heating priority selection Ochrona przed bakteriami Legionella Protection from Legionella PPUH GECO Sp z 0 0 option is disabled the Controller will only control the pump in the on off operation mode In schemes 6 10 12 14 15 and 16 the collector pump rotation speed adjustment is never active When it is set to Ci g y Continuous
2. To edit rated and minimum flow choose Ustaw parametr w Settings Config on the main menu screen and then Przep yw rotametr Flow Rotameter on the settings configuration menu screen GH20SB J RATE MEC 05571 imum 2e SLl mima SOLAR CONTROLLER On this screen you can edit gt the rated flow 0 5 30 01 min gt the minimum flow 0 rated flow 0 51 min If the Regulacja obrot w pompy P Pump P Rotation Speed Adjustment is set to Nie No the minimum flow will be hidden it cannot be edited Press V and A to switch between these settings and press to edit the highlighted setting During active edition the setting value flashes Use V and A to set a new value Press to save the new value and exit the setting edition option Press to cancel the change and exit the setting edition option Press when setting edition is not active to return to the settings configuration menu screen Press to cause the Controller to switch to the standby mode 3 3 4 6 Factory Control Settings To restore factory control settings choose Ustaw parametr w Settings Config on the main menu screen and then Nastawy fabryczne Factory Settings on the settings configuration menu screen When you choose this option the Controller will ask for confirmation of factory settings restoration Press to restore factory control settings and return to the settings configuration menu screen Pr
3. To view average collector power counters choose Liczniki energii Energy Counters on the main menu screen and then Moc kolektora Collector Power on the energy counters menu screen GH20SB CTOR POWER SOLAR CONTROLLER Report type selection option will appear on the screen Raport dobowy Daily Report Raport tygodniowy Weekly Report Raport miesieczny Monthly Report Raport roczny Yearly Report PPUH GECO Sp z 0 0 FROM 03 01 2012 VVVV GH20SB User Manual PAGE 2 When you select the desired report a list including the date and the average power value for a given time interval day week month year will appear on the screen To edit power distribution in a given time interval use V or A to select the desired time interval and press Press to go back to the previous menu 3 3 9 Holiday function Mo I aua 2s Rigas HOLID Ti 645Q o tae UE Sb 6L Vo i AA T4 259 To use the holiday function editing option choose Funkcja urlopowa Holiday Function on the main menu screen SETTINGS 61 61 01 Mo On this screen you can change the status of the holiday function and define holiday start and end date Press V and A to switch between settings and press to edit the currently highlighted setting During holiday start or end date the value being edited day month or year flashes Using V and A change the flashing edited value and press to edit the next value
4. O4 Mains power outlet 230V AC bridged within the Controller This output may be bridged outside with the switch relay output thus providing switching power supply for controlling e g a three way valve T1 T2 T3 T4 Temperature sensor inputs NTC10k Description of Controller inputs and outputs When connecting devices to the Controller outputs it must be remembered that outputs marked as O1 and O3 are live outputs to which an external device may be connected directly The O2 output is dry and to be placed in series between the power source and the external device PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 6 3 Controller Usage 3 1 Enabling the Controller After connecting the Controller to power supply the Collector will be activated in the standby mode 1f before deactivation it was in the standby mode or in the operation mode 1f before deactivation it was in the operation mode 3 2 Standby Mode In this mode the LCD display is slightly backlit and the Controller name and the current software release are shown on the screen In the standby mode all outputs remain disabled and the alarm sounds are inactive Press to cause the Controller to exit the standby mode and switch to the operation mode 3 3 Operation 3 3 1 Main Screen GH20SB Mo 11 53 2a 64 SOLAR CONTROLLER In the upper line of the LCD display on the left the number of the currently supported system sche
5. a system allowing control of pumps cooperating with collector batteries placed in various directions additionally the system controls a circulation pump Output Device connected Collector pump P Collector pump K Circulation pump C Description Collector sensor Required Tank sensor Required Collector sensor Required Tank sensor Required 6 16 Scheme 16 a system allowing control of pumps cooperating with collector batteries placed in various directions The system allows domestic hot water heating in two heaters Output Device connected Collector pump P Valve U Collector pump K Description T2 T3 T4 PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 35 6 17 Scheme 17 the basic scheme with a circulation pump allowing emergency water dump from the heater Output Device connected Collector pump P Dump valve K Circulation pump C 7 Sensor Error Alarm The Controller checks the temperature sensors for proper connection If a sensor is damaged a cable is broken or a sensor is disconnected the Controller raises alarm for that sensor in the event of sensor short circuit the Controller will nor raise alarm but indicate a temperature of 125 C In the alarm condition all outputs are disconnected additionally when the Controller displays the main screen alarm is indicated by audio signal In the alarm mode you can browse the menu system configure settings and ma
6. Selection of many language versions Easy and quick control settings configuration YYYY PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 5 2 Connecting External Devices The GH20SB Controller is equipped with 4 inputs enabling connection of NTC10k temperature sensors and three outputs enabling connection of external devices pumps or three way valves depending on the system scheme chosen A drawing contains a graphic presentation of the input and output marking The description of the Controller inputs and outputs is provided in the table PPUH GECO Sp z o o E C O 32 060 Liszki Cholerzyn 376 tel 48 12 6369811 fax 6362002 www geco pl e mail gecoQgeco pl Model GH20SB SN 0000 Prod Date C 4 T1 Temp sensor NTC10K 1 01 Main pump output Imax 3 15A T2 Temp sensor NTC10K 2 O2 Relay output dry switch relay Imax 8A T3 Temp sensor NTC10K 3 1 S2 NC normally close T4 Temp sensor NTC10K 4 S2 S3 NO normally open O3 Relay output live 230VAC Un 220 230 VAC Imax 10A O4 Main power outlet 230VAC bridget within the Controller Marking of Controller inputs and outputs Un Mains connection 30VAC 7S0Hay OI Main pump output Maximum current rating 3 15A O2 Relay output dry switch relay Maximum current rating 8A S1 S2 NC normally closed 52 83 NO normally open O3 Relay output live 230VAC V Maximum current rating 8A
7. When editing the year value press this button to save the new date and exit holiday start and end date edition Press to cancel the changes and exit the holiday start or end date edition option If the holiday function status is set to Tak Yes a change of the holiday start or end date will automatically change the status to Nie No PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 22 When editing the holiday function status use V and A to set a new value and press to save the new value and exit the holiday function status edition Press to cancel the change and exit the holiday status edition option Press 0 when setting edition is not active to return to the main menu screen Press to cause the Controller to switch to the standby mode PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual 4 Settings 4 1 Typ kolektora stonecznego Solar collector type Roznica temp TI T2 w cz pompy kolektor w T1 T2 temperatures differences for activating collector pump R nica temp w czenia dod Pompy zaworu Temperatures differences for activating additional pump valve Max temp T2 wy czenia pompy kolektor w Max T2 temperature for deactivating collector pump Min temp T3 uruchomienia pompy kot a Min T3 temperature for activating boiler pump Min temp T4 w czenia pompy cyrkulacyjnej Min T4 tempera
8. 0SB User Manual PAGE 17 3 3 5 3 Sound Settings Editing To edit sound settings choose Ustaw sterownika Controller Config on the main menu screen and then D wi ki Sounds on the Controller configuration menu screen SETTINGS rm sounds sounds On this screen you can edit gt Alarm sounds Yes No gt Keys Yes No Press V and A to switch between these settings and press to edit the currently highlighted setting During active edition the setting value flashes Use V and A to set a new value Press to save the new value and exit the setting edition option Press to cancel the change and exit the setting edition option Press when setting edition is not active to return to the Controller configuration menu screen Press to cause the Controller to switch to the standby mode 3 3 5 4 Language Selection To go to the language selection screen choose Ustaw sterownika Controller Config on the main menu screen and then Jezyk Language on the Controller configuration menu screen Use V and A to select the desired language PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 1 18 Press to save the new language settings and return to the Controller configuration menu screen Press to cancel changes and return to the Controller configuration menu screen Press to cancel changes and cause the Controller to switch to the standby mode 3 3 6 Manual
9. Ch odzenie Cooling on the main menu screen On this screen you can activate cooling and set the temperature of cooling activation and deactivation Press V and A to switch between settings Press to choose current setting editing option During edition the setting value flashes Press V and A to set a new value Press to save the new value and exit the setting edition option Press to cancel the change and exit the setting edition option Press when setting edition is not active to return to the main menu screen Press to cause the Controller to switch to the standby mode 3 3 8 Energy and Collector Power Counters The energy and collector power counters function is not available for schemes 6 10 12 14 15 16 iy STATISTICS wec tor Fower rmal ene r y enersy yield The Controller has an inbuilt module for recording average collector power and the energy generated by the collectors The Controller enables recording and readout of power and energy statistics for the following time intervals PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 20 gt Last 60 recorded days gt Last 20 recorded weeks gt Last 12 recorded months gt Last 10 recorded years Additionally for days weeks months and years statistics there 1s possibility to present the time intervals graphically by means of bar charts gt For daily statistics it is possible to graphically present the hourly dis
10. Control To go to the manual control screen choose Sterowanie r czne Manual Control on the main menu screen GH20SB O SOLAR CONTROLLER gt gt The LCD display will show the system scheme screen and on the right side of the screen letters will appear that correspond to the devices in the scheme together with a description of the external device status WY ZA ON OFF NOTE After switching to manual operation the control algorithm is wholly suspended and the user has full control over the status of the outputs external devices Depending on the selected system configuration the Controller can operate from 1 to 3 external devices Each device can be separately activated and deactivated and its current status is always shown in the system scheme and on the right side of the display next to the letter describing the device To switch between devices use V and A Press to unlock the possibility of changing the status of the currently highlighted output which 1s indicated by the flashing of the output status symbol WYL ZAL ON OFF Press V and A to change the device status and then press to lock the current output status Press to restore control and return to the main menu screen Press to cause the Controller to switch to the standby mode PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 19 3 3 7 Cooling To choose the cooling settings editing option choose
11. H MM Mo 11 56 PM YY 20 11 11 Press V and A to change to flashing edited value PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 16 Press to edit the next value If you press it when editing the year then the new time and date will be saved and you will return to the Controller configuration menu screen Press to cancel changes and return to the Controller configuration menu Press to cancel changes and cause the Controller to switch to the standby mode 3 3 5 2 Display Settings Editing To edit display settings choose Ustaw sterownika Controller Config on the main menu screen and then Wy wietlacz Display on the Controller configuration menu screen GH20SB PLAY shtnesst tandbys 1GCImin On this screen you can edit gt Display backlight intensity 1 10 gt Inactivity time after which the backlight will be automatically turned off 1 10min Press V and A to switch between these settings and press to edit the currently highlighted setting During active edition the setting value flashes Use V and A to set a new value Press to save the new value and exit the setting edition option Press to cancel the change and exit the setting edition option Press when setting edition is not active to return to the Controller configuration menu screen Press to cause the Controller to switch to the standby mode PPUH GECO Sp z 0 0 FROM 03 01 2012 GH2
12. Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie zamro eniem kolektor w No No No No No No No No No No No No No No No No No Collector freezing prevention Wyb r priorytetu grzania Heating priority selection Ochrona przed bakteriami Nie Nie EELE Legionella Protection No No las from Legionella Blokada pracy kot a K Nie uruchomieniem kot a C No Blocking boiler K operation by activating boiler C Factory control settings PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 15 3 3 5 Controller Configuration Menu Screen To go to the Controller configuration menu choose Ustaw sterownika Controller Config on the main menu screen OLLER SETTINGS EB and time Play Ta sett In the Controller configuration menu you can gt Choose date and time edition option gt Choose display settings edition option gt Choose sound edition option gt Choose language selection option Press V and A to switch between options To confirm the selection of an option press Press to return to the main menu screen Press to cause the Controller to switch to the standby mode 3 3 5 1 Editing Date and Time To go to date and time edition screen choose Ustaw sterownika Controller Config on the main menu screen and then Data i czas Date and Time on the Controller configuration menu screen AND TIME H
13. O O OO UE E MEE 35 Te ONS Error Alar AAAA WAWA WN 35 8 Information on Marking and Collection of Waste Electric and Electronic Equipment 35 PPUH GECO Sp z 0 0 Release I FROM 03 01 2012 GH20SB User Manual PAGE 4 1 Controller Description The GH20SB Controller is a device designed and manufactured to support systems with solar collectors The product was base on a reliable state of the art microprocessor technology The Controller is modern in its design and very easy to use as it is equipped with a user panel with a transparent keyboard and an LCD graphic display Its advantage is an extensive package of basic options greatly enhancing its functionality These are Y A selection of 17 various system configurations System scheme display Device operation animation in the system scheme Collector pump rotation speed adjustment External device manual control option Calculation of collector instantaneous power Inbuilt real time clock Controller status memory after disconnecting power supply Extensive average collector power statistics menu Extensive energy counters menu Holiday function Anti legionella function Collector overheating prevention function Anti freeze function Collector type selection function flat plate tube VVVVVVVVV N N NN N Additionally the Controller has been equipped with a number of features facilitating its use Transparent menu Graphic presentation of time intervals
14. P P U H Geco sp ka z o o 32 060 Liszki Cholerzyn 376 tel 012 6369811 6361290 fax 012 6362002 USER MANUAL FOR SOLAR COLLECTOR SYSTEM CONTROLLER GH20SB Software release 01A GH20SB User Manual CONTENTS I Controller Descriptio eri io icon dac e ieio re tin 4 2 Connec ns External DEVICES O a EN INNEREN OS O ROO E A DERE CS Pe eL ERR ess 5 3s Contoler Usi me 6 IL Enabhingtlie Conttoller assa S aha Gad doj 6 2 2 Standby MOJE anna 6 3 3 AO PCTAU Ora E E td O date 6 gt do Man See eea E OSA 6 oea Nn GES e Ez OE E ORA 7 33323 rO yS o CEM E Se Ie COM O O W A AO AEK O 8 3 24 et nes C ontieurati n MEMDERCEN COCA OEG OO 8 3 5 0 Controller Configuration Menu Screen ined said cda had ad GAZE 15 50 0 Mama Ce OUT Ole ces dak GRA 18 Dann COONS E cent NAC OJO Mt a 19 3 0 0 Enersy and Collector Power Counters wadowicki akc E 19 5 0 THONG AY TUNCU OM o zd AEO A doi A O WE odzie N 21 R CULM OS zee W aid zad ak AAA rper m O ECA 23 wk C onol SSN A a Eee en nor eer iot t iosuada Discite cM Ue Df er Marr ae 23 a IA COMMOMCE STINGS sek a a LS Umm 23 5s Additional EUNCHONSZ cO ODEON AO EO OAI 26 2 1 Collector Freezing PIEYCNUORTURCHOM GA EEE oh oko 26 3 25 SAMIEC cone lia PUNCH ON vais dot ONG ZJ NA GRN JAP OE 26 5 95 Houda y PUR GO ou uitio Matera tial tenes Mite itenim tede Nitemttediedo ulta ibd 26 324 Manual Cooling Funto anwad eru aeu setis e su uad wia o du satin Wd pru QD RUE 26 6 Controll
15. User Manual PAGE 25 Symbol Description Symbol Blokada pracy kot a Setting associated only with scheme 14 Allows K uruchomieniem blocking gas boiler K activity during solid fuel boiler kot a C Blocking C operation boiler K operation by activating boiler C 4 2 Controller Settings Poziom jasno ci wy wietlacza Setting defines display backlight intensity Display backlight intensity Czas wygaszenia wy wietlacza Setting defines time without any button pressed after 1 10min Display sleep time which the display becomes inactive for reasons of energy savings Dzwieki alarm w Alarm sounds Setting enabling or disabling alarm sounds when No Yes temperature sensors are disconnected or damaged D wi ki klawiszy Key sounds Setting enabling or disabling key sounds PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 26 5 Additional Functions Del Collector Freezing Prevention Function When this function is enabled the collector pump will activate if the temperature at the T1 sensor is lower than or equal to the freezing point defined in the Nosnik Ciepta Heating Medium setting and the T2 temperature is higher than 7 C The pump will deactivate if the T2 temperature falls below 5 C or the T1 2 temperature is higher than the freezing point defined in the Nosnik Ciepla Heating Medium setting Additionally in schemes 15 and 16 where a second collector is used when this functi
16. ated in boiler C 10 85 C Regulacja obrot w pompy kolektor w Nie Tak Collector pump rotation speed adjustment No Yes Tryb pracy pompy cyrkulacyjnej Przer Ci g a Circulation pump operation mode Intermittent Continuous Moc kolekt wy cz kot a grza ki pompy ciep a 100 3000W Collector power for deactivated boiler heater heat pump 100 3000W vw Vv VW Y Y Y Y V V VW PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 10 Ochrona przed przegrzaniem kolektor w Nie Tak Collector overheating prevention No Yes Max temp T2 wy ochrony przegrz kolektor w 60 85 C Max T2 temperature for deactivating collector overheating prevention 60 85 C Ochrona przed zamrozeniem kolektor w Nie Tak Collector freezing prevention No Yes Wyb r priorytetu grzania A B Heating priority selection A B Ochrona przed bakteriami Legionella Nie Tak Protection from Legionella No Yes Blokada pracy kot a K uruchomieniem kot a C Nie Tak Disabling boiler K operation by activating boiler C No Yes YYY VY V w Depending on the currently selected system scheme some of the above settings may be hidden Press and to switch between settings Press to edit the current setting During edition the setting value flashes Press V and A to define a new value Press to save the new value and exit the setting edition option Press to cancel t
17. aters allows additional heating of the boiler heater with solar energy Output Device connected Collector pump P Pump K Circulation pump C Description Collector sensor Required Tank sensor Required Sensor for calculating power energy Optional Tank sensor Required 6 8 Scheme 8 a system of two heaters allows additional heating of the circulation return with solar energy Device connected O1 Collector pump P Ol Valve U Circulation pump PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 3 6 9 Scheme 9 a system with a three way valve for domestic hot water heating and pool water heating Additional control of the pool water filtering system pump Device connected Collector pump P Valve U Pool pump C l 2 3 4 Sensor Description Collector sensor Required T2 Tank sensor Required T T T T Sensor for calculating power energy Optional T4 Pool sensor Required 6 10 Scheme 10 a system with two collector pumps for domestic hot water heating and pool water heating Additional control of the pool water filtering system pump Device connected Collector pump P Collector pump K Pool pump C T2 T3 T4 PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 32 6 11 Scheme 11 a system with a three way valve for domestic hot water heating in two solar heaters with additional control of a cir
18. between options To confirm the selection of an option press Press to return to the main menu screen Press to cause the Controller to switch to the standby mode 3 3 4 1 Control Settings Editing To edit control settings choose Ustaw parametr w Settings Config on the main menu screen and then Param sterowania Control Settings on the settings configuration menu screen GH20SB TROL i lar Llector SOLAR CONTROLLER On this screen you can change the configuration of the following settings Typ kolektora stonecznego Ptaski Rurowy Solar collector type flat plate tube R nica temp T1 T2 wy cz pompy kolektor w 2 15 C T1 T2 temperatures difference for deactivating collector pump 2 15 C R nica temp w czenia dod pompy zaworu 2 15 C Temperatures difference for activating additional pump valve 2 15 C Max temp T2 wy czenia pompy kolektor w 10 85 C Max T2 temperature for deactivating collector pump 10 85 C Min temp T3 uruchomienia pompy kotta 10 85 C Min T3 temperature for activating boiler pump 10 85 C Min temp T4 w czenia pompy cyrkulacyjnej 10 85 C Min T4 temperature for activating circulation pump 10 85 C Max temp T4 wy czenia r d a ciep a 10 85 C Max T4 temperature for deactivating heat source 10 85 C Max temp wody grzana z kot a C 10 85 C Max temperature of water he
19. culation pump Device connected Collector pump P 02____ Valve U O2 Circulation pump C l 2 3 4 Description Collector sensor Required T2 Tank sensor Required T T T T Sensor for calculating power energy Optional T4 Tank sensor Required 6 12 Scheme 12 a system with two collector pumps for domestic hot water heating 1n two solar heaters with additional control of a circulation pump Output Device connected Collector pump P Collector pump K Circulation pump C PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 33 6 13 Scheme 13 a system allowing the cooperation of collectors with the buffer container used for cooperation with the SH Output Device connected Collector pump P O2 Valve U Collector sensor Required Tank sensor Required Sensor for calculating power energy Optional SH return sensor Required 6 14 Scheme 14 a domestic hot water heating system with solar collectors Additionally the system controls a gas boiler and activates domestic hot water heating after the boiler achieves the required temperature Device connected Collector pump P Boiler K Boiler pump C Description Collector sensor Required Tank sensor Required Sensor for calculating power energy Optional Tank sensor Required PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 34 6 15 Scheme 15
20. ector systems To choose the desired configuration of the collector system choose Wyb r schematu Scheme Selection on the main menu screen GH20SB scheme When you go to the system scheme selection screen on the display screen a figure appears representing the system scheme and accompanied by its number Press V and A to change the system scheme Press to save changes and return to the main menu screen Press to cancel changes and return to the main menu screen Press to cancel changes and cause the Controller to switch to the standby mode 3 3 4 Settings Configuration Menu Screen To go to the settings configuration menu choose Ustaw parametr w Settings Config on the main menu screen GH20SB ETERS SETTINGER rol rarameters gt Program C Program K In the settings configuration menu you can Choose control settings edition option Choose circulation pump C time programme editing option Choose boiler heater K time programme editing option Choose heating medium freezing point editing option Choose rated and minimum flow editing option Choose maximum and minimum collector pump rotation speed editing option PPUH GECO Sp z 0 0 FROM 03 01 2012 VVVVV WV GH20SB User Manual PAGE 9 gt Enter factory values of control settings Depending on the currently selected system scheme some of the above options may be hidden they will not appear in the menu Press and A to switch
21. er Operation Scheme siisc ciissscesssscecsassssstesesdcacacdandacnnsasdedeessacadadeadsadacdancacasssdecdsacennacass 27 6 1 Scheme T the Basic SCHEME ze WANA Ai i Eoo aed hasan eis 27 6 2 Scheme 2 the basic scheme with a circulation pump sseeeeeeeeeeeeen 21 6 3 Scheme 3 the basic scheme with a circulation pump and a gas boiler 28 6 4 Scheme 4 the basic scheme with a circulation pump and an electric heater 28 6 5 Scheme 5 the basic scheme with a circulation pump and a heat pump 29 6 6 Scheme 6 the basic scheme with a circulation pump activating domestic hot water heating after the boiler achieves the required temperature eeeeoaaaaa aaa aaa aaa aaa aaa aaa aaa aaa aaa i 29 6 7 Scheme 7 a system of two heaters allows additional heating of the boiler heater with solar TNC EE NA 30 6 8 Scheme 8 a system of two heaters allows additional heating of the circulation return with SOME CIERCY zda emu dar us ple css eae AEO a RO A OW AA O a iee 30 6 9 Scheme 9 a system with a three way valve for domestic hot water heating and pool water heating Additional control of the pool water filtering system pump eeeeeaaaaaa anawa aaa aaa aaaaaaa 31 6 10 Scheme 10 a system with two collector pumps for domestic hot water heating and pool water heating Additional control of the pool water filte
22. ess to return to the settings configuration menu the control settings will remain unchanged The values of the factory control settings depend on the currently set system scheme PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 1 3 System scheme number me NH eae Typ kolektora P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski P aski s onecznego Solar Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat collector type plate plate plate plate plate plate plate plate plate plate plate plate plate plate plate plate plate R nica temp T1 T2 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C 6 C w cz Pompy kolektor w T1 T2 temperatures differences for activating collector pump 4 R nica temp w czenia dod pompy zaworu Temperatures differences for activating additional pump valve Max temp T2 65 C 65 C 65 C 65 C 65 C 65 C 65 C 65 C 65 C 65 C wy czenia pompy kolektor w Max T2 temperature for deactivating collector pump l d 5 C SC 65 C 65 C Min temp T3 4 5 C 3C 65 C 65 C BERR EM EN EEREN Tak Tak Yes Yes uruchomienia pompy kotta Min T3 temperature for activating boiler pump Min temp T4 w czenia 35 C 35 C 35 C 3 35 C
23. he change and exit the setting edition option Press when setting edition is not active to return to the settings configuration menu screen Press to cause the Controller to switch to the standby mode 3 3 4 2 Editing Circulation Pump C Time Programme To edit the circulation pump C time programme choose Ustaw parametr w Settings Config on the main menu screen and then Program czasowy C C Time Programme on the settings configuration menu screen GH20SB Mo Fr 5a SU SOLAR CONTROLLER The external devices operating hours setting mode allows setting time separately for week days Monday Friday and for Saturday and Sunday The horizontal arrow shown above the scale at the top of the screen indicates the hour range active for edition The edition of the time programme begins with defining the device operation on weekdays Monday Friday To change the hour displayed use V and A After setting the last hour in this range the Controller will switch to editing the time programme for Saturday and after setting the last hour for Sunday it will switch to editing the time programme for Sunday To activate or deactivate an external device at a selected hour press If the device is set to operate during the selected hour it will be indicated by a white field on the hour scale To PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 7 1 deactivate the device for the selected hour use the key to
24. ic scheme with a circulation pump Device connected O1 Collector pump P Ol Circulation pump PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 28 6 3 Scheme 3 the basic scheme with a circulation pump and a gas boiler Device connected Collector pump P 02 BoilerK O2 Circulation pump C l 2 3 4 Description Collector sensor Required T2 Tank sensor Required T T T Sensor for calculating power energy Optional T T4 Tank sensor Required 6 4 Scheme 4 the basic scheme with a circulation pump and an electric heater Device connected Collector pump P Heater K Circulation pump C PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 29 6 5 Scheme 5 the basic scheme with a circulation pump and a heat pump Device connected Collector pump P 02 HeatpumpK O2 Circulation pump C l 2 3 4 Sensor Description Collector sensor Required Tank sensor Required Sensor for calculating power energy Optional Tank sensor Required 6 6 Scheme 6 the basic scheme with a circulation pump activating domestic hot water heating after the boiler achieves the required temperature Device connected Collector pump P Boiler pump K Circulation pump C Description PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 30 6 7 Scheme 7 a system of two he
25. liday function the function is automatically deactivated so as not to activate next year This function should be set manually before any planned holidays 5 4 Manual Cooling Function The manual cooling function is available in the main menu When the cooling option is enabled or the holiday function is active and the temperature in the tank measured by the T2 sensor is higher than the cooling activation temperature the collector pump activates and remains active until the temperature in the tank measured by the T2 sensor falls below cooling deactivation temperature The pump activation is always linked with the freezing prevention function The manual cooling function is time based and 1s active between 12 midnight and the cooling end hour defined in the settings During the collector cooling only the main collector pump P operates while all other devices are inactive The only exception here is the dump valve in scheme 17 1 e it will be active if the T4 temperature is higher than the T4max temperature and it will be inactive if the T4 temperature 1s lower than the T4max 1 temperature PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 27 6 Controller Operation Scheme 6 1 Scheme 1 the basic scheme Device connected Collector pump P Description Collector sensor Required Tank sensor Required Sensor for calculating power energy Optional Tank sensor Optional 6 2 Scheme 2 the bas
26. me is shown In the middle and on the right the time and date are shown Below the time and date line on the left the system scheme and the collector pump control level are displayed The digits in the scheme represent the numbering of the temperature sensors You need to ensure that the sensors are properly installed as described in the scheme Sensor substitution may result in control system malfunction On the right of the system scheme the temperatures measured by sensors are shown T1 corresponds to the temperature measured by sensor 1 T2 corresponds to the temperature measured by sensor 2 etc The Controller is designed to ensure that it 1s not necessary to install all four temperature sensors You need to install only those sensors which are necessary for control If a sensor necessary for control 1s not installed or damaged next to the sensor symbol on the screen the word Err will appear indicating that there 1s no sensor or it is damaged In this case all external devices will be deactivated and the Controller will raise alarm indicated by an intermittent audio signal If a sensor not required for control 1s not connected to the controller or is damaged the Controller will not raise alarm and on the screen the temperature will be replaced with the symbol ec 99 PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 7 Below the displayed temperatures in the lower right hand corner of the screen the collectors instan
27. nually control the external devices The information which sensor is in alarm condition is available in the main screen The display shows Err instead of the temperature next to the sensor marking When the Controller raised sensor alarm check the system for proper connection and installation of the sensors 8 Information on Marking and Collection of Waste Electric and Electronic Equipment NOTE The symbol placed on a product or on its packaging indicates that it 1s subject to selective collection of waste electric and electronic equipment This means that the product should not be discarded with other household waste Appropriate removal of old and waste electric and electronic equipment will prevent potentially harmful effects on the environment and human health The obligation of selective equipment collection rests on the user who should deliver the equipment to a collection point PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 36 P P U H Geco Sp ka z o o 32 060 Liszki Cholerzyn 376 tel 48 12 6369811 48 12 6361290 fax 48 12 6362002 http www geco pl PPUH GECO Sp z 0 0 FROM 03 01 2012
28. on is enabled pump K will activate if the temperature at the T3 sensor is lower than or equal to the freezing point defined in the Nosnik Ciepla Heating Medium setting and the T2 temperature 1s higher than 7 C The pump will deactivate 1f the T2 temperature falls below 5 C or the T3 2 temperature is higher than the freezing point defined in the Nosnik Ciepta Heating Medium setting 3 2 Anti Legionella Function The anti legionella function applies only in schemes 3 4 and 14 It is always activated once a week in the night from Sunday to Monday at 12 midnight When the anti legionella function 1s activated the collector pump is deactivated and the boiler and additionally the circulation pump are turned on When the temperature measured by the T4 sensor exceeds 70 C the circulation pump and the boiler turn off and the anti legionella function deactivates Next time it will be activated in a week in the night from Sunday to Monday The anti legionella function does not work during holidays 2 9 Holiday Function The holiday function consists in totally disabling the control of the heater the gas boiler the heat pump the boiler pump etc Additionally when the holiday function 1s active the collector cooling function regardless of whether it is enabled and the collector overheating prevention function regardless of the value in the ZabPrzeg setting are also active When the Controller finishes the application of the ho
29. pompy cyrkulacyjnej Min T4 temperature for activating circulation pump 3 3 Max temp T4 50 C 50 C 50 C 50 C 50 C wy czenia r d a ciep a Max T4 temperature for deactivating heat source Max temp wody grzana z kot a C Max temperature of water heated in boiler C Regulacja obrot w pompy Tak Tak Tak Tak Tak Tak Tak Tak kolektor w Collector Yes Yes Yes Yes Yes Yes Yes Yes pump rotation speed PPUH GECO Sp z 0 0 FROM 03 01 2012 x adjustment GH20SB User Manual PAGE 14 Tryb pracy pompy Przer Przer Przer Przer Przer Przer Przer Przer Przer Przer Przer Przer cyrkulacyjnej Circulation Interm Interm Interm Interm Interm Interm Interm Interm Interm Interm Interm Inter pump operation mode m Moc kolekt wy cz 1500W 1500W 1500W kot a grza ki pompy ciep a Collector power for deactivated boiler heater heat pump Ochrona przed Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie Nie przegrzaniem kolektor w No No No No No No No No No No No No No No No No No Collector overheating prevention Max temp T2 wy 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C 80 C ochrony przegrz kolektor w Max T2 temperature for deactivating collector overheating prevention Ochrona przed Nie Nie
30. put out the white field above the hour scale Press to save new settings and return to the settings configuration menu screen Press to cancel changes and cause the Controller to switch to the standby mode 3 3 4 3 Editing Boiler Heater K Time Programme To edit the boiler heater K time programme choose Ustaw parametr w Settings Config on the main menu screen and then Program czasowy K K Time Programme on the settings configuration menu screen GH20SB PROGRAM Mo Fr To set the time zones for the device marked with K on the scheme follow the same procedure as when selecting working hours for circulation pump C 3 3 4 4 Editing Heating Medium Freezing Point To edit heating medium freezing point choose Ustaw parametr w Settings Config on the main menu screen and then Nosnik ciep a Heating Medium on the settings configuration menu screen TRANSFER FLUID ezing rerature When you go to this screen the setting value flashes Press V and A to define a new heating medium freezing point temperature in the range from 35 to 0 C Press to save the new value and return to the settings configuration menu Press to cancel changes and return to the settings configuration menu PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 72 Press to cancel changes and cause the Controller to switch to the standby mode 3 3 4 5 Editing Rated and Minimum Flow
31. ring system pump esses 31 6 11 Scheme 11 a system with a three way valve for domestic hot water heating in two solar heaters with additional control of a circulation pump eee ee ooo aaa aaa aaa aaa aaa aaa aaa nazwa aaa nnne 32 6 12 Scheme 12 a system with two collector pumps for domestic hot water heating in two solar heaters with additional control of a circulation pump eee eee aaa aaa aaa aaa aaa aaa aaa aaa aa aaa nennen 22 6 13 Scheme 13 a system allowing the cooperation of collectors with the buffer container used TOP COOPELatlOMs WINE OO kata En OBO SYG 33 PPUH GECO Sp z 0 0 Release I FROM 03 01 2012 GH20SB User Manual 6 14 Scheme 14 a domestic hot water heating system with solar collectors Additionally the system controls a gas boiler and activates domestic hot water heating after the boiler achieves the aui d MPERAUEC s Elo 33 6 15 Scheme 15 a system allowing control of pumps cooperating with collector batteries placed in various directions additionally the system controls a circulation pump sssssss 34 6 16 Scheme 16 a system allowing control of pumps cooperating with collector batteries placed in various directions The system allows domestic hot water heating in two heaters 34 6 17 Scheme 17 the basic scheme with a circulation pump allowing emergency water dump PLOW Re De AERO EE OP
32. taneous power is displayed as calculated by the Controller When the collector pump is deactivated or the sensor on the collector return as a rule it is sensor T3 is disconnected the power indication is replaced with the symbol For systems numbered 6 10 12 14 15 and 16 the power calculation option is not available Depending on the control status additional symbols may appear on the screen such as gt L active anti legionella function gt Holiday symbol active holiday function gt Cooling symbol active cooling function Press to cause the Controller to switch to the standby mode Press uo to cause the Controller to switch to the main menu screen 3 3 2 Main Menu Screen GH20SB Behe ne Selection rameters settinss troller settinzs SOLAR CONTROLLER On the main menu screen you can choose the following Controller functions Scheme selection Settings configuration Controller settings configuration Manual control Cooling settings configuration Energy counters view Holiday function VVVVVVV Press V and A to switch between options To confirm the selection of an option press Press to return to the main screen Press to cause the Controller to switch to the standby mode PPUH GECO Sp z 0 0 FROM 03 01 2012 GH20SB User Manual PAGE 6 3 3 3 System Scheme Selection The Controller allows controlling 17 different configurations of solar coll
33. the circulation pump 1s activated in the hours set in the Program czasowy Time Programme menu If it is set to Przerywana Intermittent the circulation pump will additionally operate in the hours set in the Program czasowy Time Programme menu however it will operate on a cyclical basis activating for 10 minutes then after 10 minutes deactivating for another 10 minutes after it will again activate for 10 minutes Setting applied in schemes 3 4 5 and 14 The Controller calculates the collector power and deactivates the boiler or the heater if the calculated power exceeds the power defined in the control setting When the collector power value is lower than the value defined in the settings the boiler heater and pump outputs are controlled in accordance with their control algorithm Setting defines enabling or disabling the boiler overheating prevention function Setting defines the maximum temperature within the tank when the collector overheating function 1s enabled This setting has priority over the T2max setting Setting enables disables the collector freezing prevention function Setting associated with schemes 9 10 11 12 and 16 Defines the priority of the tank pool heating Setting associated with schemes 3 4 and 14 Defines whether the anti legionella function is enabled or disabled Interm Contin 100 3000W 60 85 C No Yes FROM 03 01 2012 GH20SB
34. tribution of the average collector power and energy gt For weekly statistics it is possible to graphically present the distribution of average power and energy for individual days in the interval from Monday to Sunday gt For monthly statistics it is possible to graphically present the distribution of the average power and energy for individual days The interval depends on the number of days in the month viewed gt For annual statistics it is possible to graphically present the distribution of average power and energy for individual months in the year in intervals from January to December When the graphical presentation in the form of bar charts is displayed in the left upper corner of the screen the highest value in the given interval appears to which the height of each bar is scaled Additionally in the right hand upper corner the series recording date appears The energy counters menu includes also the total energy counter This counter counts on a continuous basis the energy generated since the Controller activation The statistics and the total counter may be reset anytime The reset options are to be found in the energy counters menu and available separately for the total counter and for the statistics A change of date may disturb the sequence of the recorder data To view the energy counters or reset the counters choose Liczniki energii Energy Counters on the main menu screen 3 3 8 1 Average Collector Power Counters
35. ture for activating circulation pump Max temp T4 wy czenia r d a ciep a Max T4 temperature for deactivating heat source Max temp wody grzana z kot a C Max temperature of water heated in boiler C Control Settings Setting T3355 T4 Symbol D D 2 PPUH GECO Sp z 0 0 PAGE 23 This setting applies to all system schemes and enables collector type selection Flat plate Tube The main control delta temperature difference This setting specifies the condition for activating and deactivating the collector pump When the sum of the Al setting and the tank temperature T2 exceeds the temperature measured by the collector sensor T1 the collector pump deactivates If the sum is lower than the T1 value the collector pump is active Additionally to ensure stable operation of the heating system a control hysteresis of 3 C is applied The auxiliary control delta temperature difference The setting is applied to controlling more extensive systems Setting associated with temperature sensor T2 located inside the tank This setting specifies the maximum allowable temperature measured by the sensor T2 which when exceeded causes the collector pump to stop Setting applied in schemes 6 and 14 It defines the minimum boiler pump K activation temperature Setting associated with the circulation pump and the T4 sensor It defines the minimum circulation pump activation temperature T4