Home
36 x 4W LED Alu CW/WW User Manual
Contents
1. 8 36 4W LED Alu CW WW User Manual Code ELUM044 WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment Do not open the equipment not modify the equipment Do not connect thi
2. 255 Strobe slow to fast 0 255 17 Colour Temperature Macro Selector 0 15 Dimmer curve and response select on fixture 16 45 Dimmer curve Linear response halogen 76 105 Dimmer curve Inverse Square response halogen 46 75 106 135 166 195 196 225 DMX 512 DMX Digital Multiplex is a universal protocol used as form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX o
3. TERMINATIONS If this equipment is operated any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Overview You should find inside the Elumen 8 carton the following items 1 36 x 4W LED Alu CW WW 2 Instruction manual 3 Power Cable Technical Specifications DMX channels 2 5 or 6 selectable 36 x 4W CW WW LEDs Dimming master slave and DMX modes 400Hz refresh rate 5 pin XLR in out sockets 4 push button menu with LCD display Powercon in socket Beam angle 30 degrees Power supply 100 240V 50 60HZ Power consumption 151W Weight 4 9Kgs Operating modes 1 Dimming 0 100 2 DMX 3 Master slave 4 Channel select 5 Dimming curves Overview FUSE F2A 250V CO IN DMX 3 O Q CER LCD DISPLAY 0 ENTER DOWN www elumen8s co uk Operation 1 Dimming Mode To enter the dimming mode press the MODE button to show DIMMER on the LCD display Now press the ENTER button and use the UP DOWN buttons to set the brightness of the Cool White LEDs from 00 99 Now press the ENTER button again and u
4. data transmission in place 3 pin 5 Pin XLR fixtures may be implemented 3 pin DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion Bai XLR socket 1 GND screen Pin 2 Signal 5 3 Signal Pin 5 NIC Pin XLR Ss Bin Pin 2 Sign Pin 3 Signal 2 3 Pin XLR socket Pin 1 GND soreen Pin 2 Signal Pin 3 Signal 5 XLR socket Pin 1 GND Sereen Pin 2 Signal En Si pignal Pin 5 NIC lumen8 www elumensg co uk
5. near as DMX value is increased SQUARE light intensity control is finer at low levels and coarser at high levels INVERSE SQUARE light intensity control is coarser at low levels and finer at high levels S CURVE light intensity control is fine at low levels and high levels and coarser at medium levels 4 Channel Mode To enter the channel mode first press the mode button to show CHANNEL on the LCD display Now press the ENTER button and use the UP and DOWN buttons to select 2 5 or channel mode 5 DMX Mode To enter the DMX mode press the MODE button to show DMX MODE on the LCD display Now press the ENTER button and use the UP and DOWN buttons to select the DMX address from 001 512 When you are happy with your setting press the ENTER button to confirm it Preset Colour Temperature Macro Mode To enter the Preset Colour Temperature Macro mode press the ENTER button to show PRESET on the LCD display Now press the ENTER button and use the UP and DOWN buttons to select from the 17 built in preset colour temperature macros Note 1 Warm 17 Cool DMX Charts 2 channel mode Value Function 0 255 Cool White Dimming 0 100 0 255 Warm White Dimming 0 100 5 channel mode 0 255 Cool White 0 255 Warm White 0 255 H5 0 255 Strobe slow to fast 0 255 17 Colour Temperature Macro Selector 6 channel mode H6 0
6. peration The 36 x 4W LED Alu CW WW can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin or 5 pin XLR connector for data input output figure 1 Figure 1 Also remember that DMX cable must be daisy chained and cannot be split Notice Be sure to follow figures 2 amp when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour DMX 512 out 3 pin XLR XLR MALE SOCKET common XLR FEMALE SOCKET 2 cold 1 ground 1 2 cold 3Hot FIGURE Special Note Line termination When longer runs of cable are used you may need to use a terminator the last unit to avoid erratic behaviour XLR Pin Configuration DMX 512 in 3 pin XLR Pin 1 Ground Pin 2 Negative Pin 3 Postive FIGURE 2 Termination reduces signal transmission problems and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number 90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin connectors for
7. s equipment to a dimmer pack Do not switch the equipment and off in short intervals as this will reduce the system s life Only use the equipment indoors not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DE
8. se the UP and DOWN buttons to set the brightness of the Warm White LEDs from 00 99 Now press the ENTER button a final time to add strobe and use the UP and DOWN buttons to change the flash speed from 00 99 NOTE CW WW 99 Dimming 00 off 99 full on F 99 Flash 00 off 99 fast When you are happy with your choice press the ENTER button to confirm it 2 Slave Mode To enter slave mode press the MODE button to show SLAVE on the LCD display Now the unit will follow in sequence with the master unit 3 Dimming Curve Mode The 36 x 4W CW WW Alu includes two sets of dimming curves The first is a Halogen emulation mode with a very smooth slow dimming and a small delay The second is an LED response with faster dimming and no delay To enter the dimming curve mode press the MODE button to show DIMMER CURVE on the LCD display Now press the ENTER button and use the and DOWN buttons to select between the 4 dimming curves from 01 08 1 4 for halogen response type 01 Linear 02 Square 03 Inverse square 04 5 8 are for LED response type 05 Linear 06 Square 07 Inverse square 08 S curve When you are happy with your setting press the ENTER button to confirm it LINEAR SQUARE INVERSE SQUARE S CURVE LINEAR the increase in light intensity appear to be li
Download Pdf Manuals
Related Search
Related Contents
レーザ距離計LDM-i150[Bluetooth機能搭載] カタログ (PDF) EPSON PX-20000 取扱説明書2 詳細編 MANuAl - BZB Express T'nB CIPCRJPH37331 telephony cable UK - Sondex Massive Aro ELAN DIGITAL SYSTEMS LTD. USBpulse100 USER'S GUIDE Copyright © All rights reserved.
Failed to retrieve file