Home

INV10120700 / INV20120700 / INV30120700

image

Contents

1. the black terminal 9 NEG to the negative pole of the power source battery the red terminal 8 POS to the positive pole of the power source battery Integrate a DC fuse holder in the positive wiring but do not place the fuse yet Assemble the DC wiring exactly as indicated Do not place anything between the ring terminal and the terminal surface Make sure that all DC connections are tight Recommended torque 11 7 13 Nm 104 115 InLbs Chassis ground Use a cable AWG8 6 mm to connect the CHASSIS GROUND terminal 7 to the central ground Remote operation switch option If you want to operate the Inverter on a remote location you can install a switch as indicated in figure 2 When the contact is closed the Inverter is switched on Battery Figure 2 USER S MANUAL 700 1000 1500 WATT INVERTER COMMISSIONING AFTER INSTALLATION 1 Check the polarity of the DC connections Do not place the DC fuse if the polarity is not correct 2 Place a DC fuse see SPECIFICATIONS in the fuse holder When placing this fuse a spark may occur caused by internal capacitors of the Inverter This is normal 3 AC voltage the load can be plugged into the AC output ref 2 directly OPERATION Switching on Move the main switch ref 1 to ON The Inverter will start a self test indicated by two beeps from the buzzer and flashing LED indicators This may last for approximate two seconds Finally the buzze
2. 1 1 1 DIP switch S4 is used to select the output frequency Output frequency 54 50 2 0 60Hz 1 NEUTRAL GROUNDING IN 120V MODELS The neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation In accordance with the National Electrical Code requirements that separately derived AC sources such as inverter and generators have their neutral conductors tied to ground in the same way that the neutral conductor from the utility is tied to ground at the AC breaker panel For models configured with a transfer relay while AC utility power is presenting and the Inverter is in bypass mode this connection neutral of the Inverter s AC output to input safety ground is not present so the utility neutral is only connected to ground at your breaker panel as required A NEUTRAL GROUNDING IN 230V MODELS There is no connection made inverter interior between either the line or neutral conductor to the safety ground WARNING Risk of electronic shock Use only Pass and Seymour type 2091 W or 2094 W ground fault circuit interrupter receptacles Others may fail in operating the inverter when connecting to the inverters equipment LED indicators S He midte me input a 2 GEES d Warning innen polarity 1 wi amage uni L POS NEG Chassis Ground USER S MANUAL 700 1000 1500 WATT INVERTER INSTALLATION Choosing a location to install Inst
3. 8 6V 0 5V 14 3V 0 5V 14 3V 0 5V 28 6V 0 5V Maximum allowed ripple DC 5 RMS Input current Meer Adr 64A 32A 64A 64A 32A External DC fuse 100 50A 100A 100A 50A Recommended ee gt 100Ah gt 100Ah gt 100Ah gt 100Ah gt 100Ah fy upto3M 16mm2 AWG4 16mm2 AWG4 16mm2 AWG4 16mm2 AWG4 16mm2 AWG4 No load power consumption Off mode OmA OmA OmA OmA FAMAM Saving 0 25A 0 15A 0 25A 0 25A 0 15A ON Unom 125A 0 64A 1 20A 1 20A 0 60A Operating T Full specifications at ambient temperature 0 to 40 C 32 to 104 F temperature specified Derating with 5 C 3 F at 40 to 60 C 104 to 140 F eee Shutdown at over temperature auto recover after cooling down Practical operating temperature may not meet specified tolerances Ambient temperature 25 to 40 C 13 to 104 F Derating with 5 C 8 F at 40 C to 60 C 104 to 140 F Shutdown at over temperature auto recover after cooling down Cooling Temperature and load regulated fan Non operating temperature Ambient temperature 30 C to 70 C 22 F to 158 F storage temperature x Protected against humidity and condensing air by conformal coating on both Relative humidity sides of all PCB s Max 95 relative humidity non condensing Safety Meet UL458 EN 60950 1 EMC FCC class A EN55022 EN61000 3 2 EN61000 3 3 EN55024 e mark N A N A N A N A N A Protections Overload short circuit over under voltage over tempe
4. A OmA OmA OmA FAMAM Saving 0 25A 0 15A 0 25A 0 25A 0 15A ON Unom 1 25A 0 64A 1 20A 1 20A 0 60A Operating T Full specifications at ambient temperature 0 to 40 C 32 to 104 F RR pna Eee Derating with 5 C 3 F at 40 to 60 C 104 to 140 F Shutdown at over temperature auto recover after cooling down tolerances uc und Ambient temperature 25 to 40 C 13 to 104 F Derating with 5 3 at 40 C to 60 104 to 140 may not meet specified tolerances Shutdown at over temperature auto recover after cooling down Cooling Temperature and load regulated fan Non operating temperature Ambient temperature 30 C to 70 C 22 F to 158 F storage temperature E Relative humidty dos of al BOB Max 0876 relate ay conformal coating boih Safety Meet UL458 EN 60950 1 EMC FCC class A EN55022 EN61000 3 2 EN61000 3 3 EN55024 e mark N A N A N A N A N A Protections Overload short circuit over under voltage over temperature Reversed polarity Internal fuse reversed polarity may lead to permanent damage DIMENSIONS 700 Watt 71 5 2 83 1000 Watt 88 0 3 46 1500 Watt 88 0 3 46 700 Watt 179 7 05 1000 Watt 182 7 17 1500 Watt 191 7 52 10 H3E33ANI JAWM INIS 700 Watt 151 5 94 1000 Watt 151 5 94 1500 Watt 151 5 94 USER S MANUAL 700 1000 1500 WATT INVERTER 700 Watt 273 10 8 1000 Watt 340 13 4 1500 Watt 370 14 6 196 7 72 MARINC
5. O 33 5 1 32 43 5 1 71 43 5 1 71 700 Watt 163 6 42 1000 Watt 166 6 54 1500 Watt 175 6 89 EC DECLARATION OF CONFORMITY Manufacturer Marinco Address Westbrook Crossing Menomonee Falls WI 5305155 Paul Mattews Rd Represented in the EU by Mastervolt B V Address Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Herewith declares that products INV10120700 12 700 230V EU INV10240700 24 700 230V EU INV10121000 12 1000 230V EU INV10241000 24 1000 230V EU INV10121500 12 1500 230V EU INV10241500 24 1500 230V EU Are in conformity with the provisions of the following EU directives e 2004 108 EMC Directive e 2006 95 Low Voltage Directive e 2011 65 EU RoHS Directive The following harmonised standards have been applied Generic emission standard EN 55022 2010 Generic Immunity standard EN 55024 2010 Low voltage standard EN 60950 1 2006 A11 2009 A1 2010 Amsterdam 19 12 2013 H A Poppelier Manager New Product Development 11 MARINCO N85W 12545 Westbrook Crossing Menomonee Falls WI 53051 Phone 800 307 6702 or 262 293 1700 Fax 262 293 7022 Email info Marinco com
6. USERS MANUAL INV10120700 INV20120700 INV30120700 INV10121000 INV20121000 INV10121500 INV20121500 INV30121500 INV10240700 INV20240700 INV10241000 INV10241500 INV20121500 Pure sine wave inverter MARINCO N85W 12545 Westbrook Crossing Menomonee Falls WI 53051 ENGLISH PAGE 1 www marinco com 10000006303 03 QUICK INSTALLATION INSTRUCTIONS This section provides a brief Connect the battery to the DC input overview of a basic stand alone Integrate a fuse holder in the positive installation of the Inverter battery wire but do not place the fuse yet However please review the entire manual for connection of additional features and to ensure best performance and years of trouble free operation Use isolated tools Read safety instructions Red wire Black wire page 3 POS NEG Disconnect the electrical power Connect e red wire to Switch off all consumers e black wire to Switch off all charging systems Incorrect polarity Remove the battery fuse will damage the Check with a suitable Inverter voltmeter whether the DC installation is voltage free Move the main switch of the Inverter to 6 The AC load can be connected directly to the OFF position the AC socket For safe installation e Connect the chassis ground terminal for 120V the AC output ground wire to the central groun
7. all the Inverter in a well ventilated room protected against rain snow spray vapour bilge moisture and dust Ambient temperature 25 40 C 13 104 F Never use the Inverter at a location where there is danger of gas or dust explosions Mount the Inverter in such a way that obstruction of the airflow through the ventilation openings is prevented No objects must be located within a distance of 10 cm 4 inch around the Inverter Do not install the Inverter in the same compartment as the batteries Do not mount the Inverter straight above the batteries because of possible corrosive sulphur fumes Before you start Be sure that the output of the supplying source battery is switched off during installation Also be sure that no consumers are connected to the battery during installation to prevent hazardous situations Before installing the Inverter make sure the main switch figure 1 ref 1 is set to the OFF position Check that the battery voltage is the same as the input voltage of the Inverter e g 24V battery for Grounding Remote operation point switch option Inverter a 24V input voltage Also check that the output voltage satisfies loading requirements A DC fuse holder must be integrated in the positive wiring The DC fuse should be placed last of all e Use four 24 5mm No 8 screws to mount the Inverter to a solid surface See figure 3 Wiring e Connect DC wiring as shown in figure 2
8. ding point of the vehicle ship Mount the Inverter with four screws to a solid If you need to install a Residual Current surface Allow at least 10 cm 4 inch space Device RCD in the wiring of the 230V AC around the apparatus output both the earth PE GND and the neutral N of the AC output of the Inverter must be connected to the grounding point 120V AC sockets contain a GFCI per output To switch on the AC output push the reset button reference R Refer to local applicable regulations on these issues Q Check all wiring If all wiring is OK e Place the inverter fuse e Switch on the Inverter USER S MANUAL 700 1000 1500 WATT INVERTER PRODUCT DESCRIPTION AND APPLICATION The Marinco inverters convert a DC voltage to a pure AC sine wave voltage SAFETY INSTRUCTIONS WARNING Before using the Inverter read and save the safety instructions e Use the Inverter following the instructions and specifications stated in this manual e Connections and safety features must be executed according to the locally applicable regulations e Operation of the Inverter without proper grounding may lead to hazardous situations e Use DC cables with an appropriate size Integrate a fuse in the positive wiring and place it nearby the battery Refer to the specifications e f the positive and negative wires on the DC input battery are exchanged the Inverter will be damaged Damage of this kind is no
9. e apparatus itself the STATUS LED turns red Indication of the LED Meaning Power OK Power saving mode see DIP SWITCH SETTINGS DC input voltage too high GREEN uninterrupted GREEN slow blinking RED fast blinking RED slow blinking DC input voltage too low 22 22 22 ce Internal temperature too RED intermittently blinking high RED uninterrupted Overload short circuit Maintenance No specific maintenance is required If necessary use a soft clean cloth to clean the Inverter Never use any liquids acids and or scourers Check the wiring on a regular base Defects such as loose connections burnt wiring etc must be corrected immediately DECOMMISSIONING Proceed as follows for decommissioning of the inverter 1 Move the main switch ref 1 to the OFF position 2 Remove the DC fuse Be sure that others can not reverse this action taken 3 Now the inverter can be demounted in a safe way USER S MANUAL 700 1000 1500 WATT INVERTER TROUBLE SHOOTING Consult an installer if you cannot solve the problem by means of the table below Problem Possible cause No output voltage all LED indicators are off OFF position Main switch ref 1 is set to Main switch ref 1 is set to the What to do Set the main switch ref 1 in ON position Set the main switch ref 1 in ON position REMOTE but no remote present The remote switch is off if applied Interna
10. e wave voltage apparatus ee Supplier Marinco General vU 12VDC 10 2 24VDC 20 3 12VDC 10 2 12VDC 10 2 24VDC 20 3 ge 15 0VDC 30 0VDC 15 0VDC 15 0VDC 30 0VDC Nom Power Tamb 40 C cos phi 1500W 1500W 1500W 1500W 1500W Max peak load 3000W 3000W 3000W 3000W 3000W Output waveform True sinewave THD lt 3 Maximum efficiency 88 93 90 90 93 Output voltage 120V 5 230V 3 230V 3 230V 3 230V 3 60Hz 0 05Hz 60Hz 0 05Hz 60 Hz 0 05Hz 50 60 Hz 0 05Hz 50 60 Hz 0 05Hz AC outlet Schuko UK Australia Universal Dimensions LxWxH chapter Dimensions Weight 48kg 10 5Lbs 4 8kg 105Lbs 4 8kg 10 5Lbs 4 8kg 10 5Lbs 4 8 9 10 5165 Protection degree IP21 IP21 IP21 IP21 IP21 Technical Technology HF Switch mode I EAE 10 2V 0 5V 20 3V 0 5V 10 2V 40 5V 10 2V 0 5V 20 3V 0 5V 25 2 0 5V 12 7V 0 5V 12 7V 0 5V 25 2 0 5 15 3V 0 5V 30 6V 0 5V 15 3V 0 5V 15 3V 0 5V 30 6V 0 5V ee ee eee NE p VONAST FA IV 05V 28 6V 0 5V 14 3V 0 5V 14 3V 0 5V 28 6V 0 5V Maximum allowed ripple on DC 5 RMS Input current 125 64 125 125 64 External DC fuse 150 100A 150A 150A 100A Recommended 150Ah 150Ah 150Ah 150Ah 150Ah battery capacity fy upto 3m 25mm2 AWG4 25mm2 AWG4 25mm2 AWG4 25mm2 AWG4 25mm2 AWG4 No load power consumption Off mode OmA Om
11. errors in this manual the consequences of these e Use that is inconsistent with the purpose of the product USER S MANUAL 700 1000 1500 WATT INVERTER SPECIFICATIONS Model Inverter 12 700 120V US 24 700 120V US 12 700 230V Br 12 700 230V EU 24 700 230V EU Part number INV20120700 INV20240700 INV30120700 INV10120700 INV10240700 Function of the o gt Conversion of a DC voltage to a pure AC sine wave voltage apparatus eee Supplier Marinco General Sores SEE 12VDC 10 2 24VDC 20 3 12VDC 10 2 12VDC 10 2 24VDC 20 3 ge 15 0VDC 30 0VDC 15 0VDC 15 0VDC 30 0VDC Nom Power Tamb 40 C cosphi 700W 700W 700W 700W 700W Max peak load 1400W 1400W 1400W 1400W 1400W Output waveform True sinewave THD lt 3 Maximum efficiency 89 91 91 91 93 Output voltage 120V 5 120V 5 230V 3 230V 3 230V 3 60Hz 0 05Hz 60Hz 0 05Hz 60 Hz 0 05Hz 50 Hz 0 05Hz 50 Hz 0 05Hz AC outlet Schuko Australia Universal Dimensions LxWxH See chapter Dimensions Weight 27kg 5 4Lbs 2 7kg 5 4Lbs 2 7kg 5 4Lbs 2 7kg 5 4Lbs 2 7kg 5 4Lbs Protection degree IP21 IP21 IP21 IP21 IP21 Technical Technology HF Switch mode I EAE 10 2V 0 5V 20 3V 0 5V 10 2V 0 5V 10 2V 0 5V 20 3V 0 5V p uode quU 25 2V 40 5 12 7V 0 5V 12 7V 0 5V 25 2V 0 5 15 3V 0 5V 30 6V 0 5V 15 3V 0 5V 15 3V 0 5V 30 6V 0 5V Aigbe PNA See t ee ee eee p VONAST FA IV 05V 2
12. l GFCI tripped DC fuse blown No output voltage STATUS LED ref 5 is slowly blinking green No output voltage STATUS LED ref 5 is fast blinking red No output voltage STATUS LED is Slowly blinking red battery No output voltage STATUS LED is intermittently blinking red inverter Airflow insufficient No output voltage STATUS LED is uninterruptedly lit red Inverter switches on and oft STATUS LED is slowly blinking Inverter is in power saving mode DC input voltage too high DC input voltage too low flat Too much load connected to the Close the remote operation switch Press the reset button ref 6 Replace the fuse Increase the load or adjust the power setting mode See DIP SWITCH SETTINGS Check battery voltage switch off charger The inverter will switch on again when the input voltage is lt 14 3 lt 28 6V Charge the battery The inverter will switch on again when the input voltage is gt 12 5V gt 25 0V Reduce the load and let the inverter cool down The inverter will switch on again when the internal temperature is lt 45 C 113 Check the airflow through the inverter The operation of the cooling fan may not be blocked Output overloaded or short circuit Reduce the load and or check the AC wiring for possible short circuits Then reset the inverter manually by switching the main switch off and on again DC input voltage too low because Reduce the length of the DC cables or use of v
13. o load power consumption Off mode OmA Power Saving Mode 0 25A 0 25A 0 15A ON Unom 1 25A 1 20A 0 60A Operating temperature Full specifications at ambient temperature 0 to 40 C 32 to 104 F specifie Derating with 5 C 3 F at 40 to 60 C 104 to 140 F d PA ee Shutdown at over temperature auto recover after cooling down pee cee er Ambient temperature 25 to 40 C 13 to 104 F may not meet specified Detating with 5 C 3 F at 40 C to 60 C 104 to 140 F Shutdown at over temperature auto recover after cooling down Cooling Temperature and load regulated fan Non operating temperature Ambient temperature 30 C to 70 C 22 F to 158 F storage temperature Protected against humidity and condensing air by conformal coating on both sides of all PCB s Relative humidity Max 95 relative humidity non condensing Safety Meet UL458 EN 60950 1 EMC FCC class A EN55022 EN61000 3 2 EN61000 3 3 EN55024 e mark N A N A N A Protections Overload short circuit over under voltage over temperature Internal fuse reversed polarity may lead to permanent damage Reversed polarity USER S MANUAL 700 1000 1500 WATT INVERTER SPECIFICATIONS Model Inverter 12 1500 120V US 24 1500 230V 12 1500 230V Br 12 1500 230V EU 24 1500 230V EU Part number INV20121500 INV30241500 INV30121500 INV10121500 INV10241500 Function of the Conversion of a DC voltage to a pure AC sin
14. oltage drop across the DC cables with a larger gauge red cables due to too long or too narrow cables Flat battery Loose or corroded connections Some loads like televisions and clocks do not operate correctly GUARANTEE TERMS Marinco guarantees that this product was built according to the legally applicable standards and stipulations During production and before delivery all products are exhaustively tested and controlled If you fail to act in accordance with the regulations instructions and stipulations in this user s manual damage can occur and or the product will not fulfil the specifications This may mean that the guarantee will become null and void The guarantee is limited to the costs of repair and or replacement of the product by Marinco only Costs for installation labour or shipping of the defective parts are not covered by this guarantee Disconnect the load and recharge the battery Tighten the connections burnt cables must be corrected immediately Wrong setting of output frequency Check the specified input frequency of the load with the output frequency of the Inverter If necessary adjust the output frequency See DIP SWITCH SETTINGS For making an appeal on warranty you can directly contact your supplier mentioning your complaint application date of purchase and part number serial number The standard guarantee period is 2 years LIABILITY Marinco cannot be held liable for e Possible
15. r will produce another beep and the Inverter will switch on indicated by two green LED indicators Now the Inverter is ready to supply load connected to the AC output Switching off Move the main switch ref 1 to the OFF position Note that switching off the Inverter does not break the connection to the batteries Remote operation The Inverter can be operated on a remote location by means of an optional remote switch Move the main switch ref 1 to the REMOTE position When the remote contact is closed the Inverter is switched on LED indicators See figure 3 The operation of the inverter is made visible by means of LED indicators 3 4 and 5 INPUT LEVEL ref 3 displays the input voltage of the inverter Input voltage V Indication of the LED 12V models 24V models RED blinking slow 10 3 10 6 20 5 21 2 RED 10 6 11 0 21 2 21 8 ORANGE 11 0512 1 21 8 24 1 GREEN 12 1 14 2 24 1 28 6 ORANGE blinking 14 2 15 0 28 6 30 0 RED blinking fast gt 15 0 gt 30 0 LOAD LEVEL ref 4 shows the output load level sc Power level W Model 700 1000 1500 LED off 0 56 0 80 0 120 GREEN 56 230 80 330 120 495 ORANGE 230 525 330 750 495 1125 RED 525 672 750 960 1125 1450 RED blinking 2672 gt 960 gt 1450 STATUS ref 5 shows the operation mode of the inverter As long this LED isn t illuminated red no failure is detected the inverter is operating normally If an error occurs it is detected by th
16. rature Reversed polarity Internal fuse reversed polarity may lead to permanent damage USER S MANUAL 700 1000 1500 WATT INVERTER SPECIFICATIONS Model Inverter 12 1000 120V USA 12 1000 230V EU 24 1000 230V EU Part number INV20121000 INV10121000 INV10241000 seis the Conversion of a DC voltage to a pure AC sine wave voltage Supplier Marinco General Input voltage 12VDC 10 2 15 0VDC 12VDC 10 2 15 0VDC 24VDC 20 3 30 0VDC Nom Power Tamb 40 C 1000w 1000W 1000W cos phi 1 Max peak load 2000W 2000W 2000W Output waveform True sinewave THD lt 3 Maximum efficiency 89 91 94 Output voltage 120V 5 230V 3 230V 3 Frequency selectable 60Hz 0 05Hz 50 Hz 0 05Hz 50 Hz 0 05Hz AC outlet GFCI Schuko UK Australia Universal Dimensions LxWxH See chapter Dimensions Weight 4 0 kg 8 8 Lbs 4 0 kg 8 8 Lbs 4 0 kg 8 8 Lbs Protection degree IP21 IP21 IP21 Technical Technology HF Switch mode PU 050 10 2V 0 5V 20 3V 0 5V p a 12 7V 0 5V 12 7V 0 5V 25 2 0 5V EPI OO O OWD Vonage iT 05 15 3V 0 5V 30 6V 0 5V BOG 14 0 5V 14 0 5V 28 6V 0 5V Maximum allowed ripple DC 5 RMS current nominal 92A 92A 46A External DC fuse 100 100 50 Recommended battery capacity gt 100Ah gt 100Ah gt 100Ah up to 3m 25mm2 AWG4 25mm2 AWG4 25mm2 AWG4 N
17. t covered by guarantee Check whether all connections are connected correctly before placing the fuse e Do not connect the AC output of the inverter to an incoming AC source e Never connect the Inverter in parallel with any other inverter e Never open the housing as high voltages may be present inside UNPACKING The delivery consists of the following parts e heinverter e This user s manual e Four ring terminals After unpacking check the Inverter for possible damage Do not use the Inverter if it is damaged If in doubt contact your supplier DIP SWITCH SETTINGS Under normal circumstances there is no need to change the default settings of the DIP switches the inverter is immediately ready for use See figure 1 On the front side of the inverter four DIP switches ref 6 can be found to adjust the inverter in accordance with your personal preferences 1 Main switch 2 AC output SINE WAVE INVERT R On Ll ole Remote Figure 1 To save energy from the battery in no load operation DIP switches S1 S2 and S3 can be used to adjust the Power Saving Mode The Power Saving Mode scans the output and when it detects a load which is higher than the selected threshold value the inverter is switched on automatically Power Saving Mode 51 S2 S3 Model 700 1000 1500 DISABLE DISABLE 0 0 0 15W 20W 1 0 0 30W 40W 0 1 0 40W 55W 1 1 0 56W 75W 0 0 1 7OW 95W 1 0 1 84W 115W 0 1 1 100W 135W