1. Button see 3 above 4 9 The system is designed to stop attempts to re open the Shut Off Device during an alarm Whilst the Alarm is still running attempts to close the Actuator by pulling down on the Reset Button will be prevented and the device will close again If a Re set cannot be made the override system is working correctly 4 9 Ensure that the gas supply is open as your system check is now completed Fix the Detector s and the the Control Panel in place using the fixings provided 5 Post Installation Checks It is recommended that you check your Detectors are functioning correctly every 3 months by pressing the TEST button Ensure that the Detectors are not damaged and remove any dust which may accumulate to ensure they can operate effectively If the FAULT Light is lit contact your supplier The Detectors should be replaced every 5 years IMPORTANT This system has been designed to provide Visual and Audible Alarms in the event of dangerous gas levels being reached and close off the gas supply to prevent further build up of these gases It is vital that you protect yourself and other occupants by taking the following steps Get fresh air into the premises by opening doors and windows Call a qualified technician and have the problem fixed before restarting appliances If anyone is experiencing symptoms of carbon monoxide poisoning headaches dizziness vomiting call for Medical help and immediately move to
2. Flewtech CONTROLS LIMITED A PEERLESS COMPANY WIRELESS GAS DETECTION amp SHUT OFF SYSTEM INSTRUCTION MANUAL Flowtech Controls Ltd 2009 Flowtech CONTROLS LIMITED A PEERLESS COMPANY Wireless Gas Detection amp Shut Off System User Manual amp Instructions Please read and follow these instructions prior to installation of the system as correct installation is Critical to the performance of the system The system has been designed for Residential premises to detect harmful levels of combustible and or toxic gases and provide visual and audible alarms when preset levels are reached When fitted the system will also activate a shut off device to close the gas supply and prevent further build up The installation of this system or any detector is no substitute for the proper installation and maintenance of fuel burning appliances by a competent person in line with the manufacturers or industry guidelines Effects of Carbon Monoxide CO Carbon Monoxide is a highly toxic gas which is produced when fuels are burnt it has no odour or colour or taste to detect its presence Exposure to high levels of carbon monoxide can cause many symptoms and result in death Symptoms can range from headache nausea vomiting and drowsiness through to unconsciousness convulsions cardio respiratory failure and death The Flowtech System is the only wireless detection and shut off system produced under exclusive license from the pat
3. accessible Tighten the 2 screws which secure the Arm to the Valve Lever Connect the power supply lead from the Actuator to the Control Panel Metal Fixing Bracket Manual Reset Button Metal Control Arm 4 Installation Check When the Actuator or Valve has been fitted and connected to the Control Panel power on the Control Panel and the Detectors to run an Installation Check This sequence will check that the Detectors can conduct wireless communication with the Control Panel that the Control Panel can supply signals and power to the Shut Off Device and that all Reset Functions are working correctly We advise that this check is conducted prior to fixing the Detectors and Control Panel in place 4 1 When power is supplied to the Control Panel the POWER light will be lit GREEN Fi wtech CONTROLS LIMITED A PEERLESS COMPANY WIRELESS ALARM SYSTEM CE TOEODBE POWER TEST ALARM 4 SEGE When power is supplied to the CO Carbon Monoxide Detector s the GREEN LED POWER light will 4 2 be lit 4 3 When power is supplied to the Gas Detector s the GREEN LED POWER light will start to flash This indicates the warm up period It will stop flashing after approximately 3 5 minutes This is required for the sensor in the detector to stabilise and will occur whenever power is re connected 4 4 The Control Panel is designed so that Detectors have to be paired with it by receiving an unique Code When all Detec
4. a location that has fresh air Ensure all occupants are accounted for Do not re enter the premises until it has been aired out and the problem corrected 5 1 Maintenance To ensure the continued operation of your system we recommend the following steps be taken a Ensure that the holes and vents on the gas detectors and Alarm Panel are free from dust or cobwebs If they require cleaning disconnect the power and lightly brush the holes and vents with a soft brush b Never use chemicals to clean the detectors or Alarm panel c Never allow water to enter the detectors of Alarm panel 5 2 Fault Lights In the unlikely event of a Gas Detector showing a YELLOW Fault Light will light up and the detector will sound If this occurs disconnect power to the detector clean as above at 5 1 and re connect the power supply Repeat if necessary If this does not rectify the fault please contact your supplier for further assistance 6 Technical Information 6 1 Carbon Monoxide Detector Power Supply 230v AC Static Current lt 140 pA Alarm Current 60 MA Alarm Volume 85 db Working Environment Temperature 0 50 C Humidity 25 85 Wireless Range 200m Open Ground The response time of this alarm conforms with EN50291 CO Level PPM 50 PPM 100 PPM 300 PPM 400 PPM Response Time 60 90 mins 10 40 mins lt 3 mins Immediately 6 2 Gas Detector Natural Gas LPG Power Supply 230v AC Warm Up Current Sta
5. el location and fitting CEEE l wtech j i i B Lint The Control Panel receives Wireless signals from the TERR Detector s and provides power to the Shut Off E Hi KENI 1 Device s Location of the Control Panel will be such that the chosen Shut Off Device can be connected with the lead from the Control Panel and the Control Panel can be connected to the power supply This may vary depending on the Shut Off Device selected If the Valve option is chosen installation MUST be made by a qualified Gas Installation Engineer When you have chosen a location for your Control Panel ensure that the Control Panel can be connected to the required power supply Do not power on yet or fix to the wall Wireless communications links need to be checked during installation to ensure that the system operates fully 3 Actuator fitting and connections The Actuator which closes the gas supply in the event of an alarm is designed to be fitted to the Gas Meter Control Valve located next to the Gas Meter The Actuator is supplied with 2 sets of metal fixing brackets which secure the Actuator to the Gas Meter Control Valve Select the brackets which match the Gas Meter Control Valve and secure the Actuator to the Gas Meter Control Valve The Actuator has a Metal Control Arm which is secured around the Lever of the valve by 2 screws provided During installation ensure that the Actuator is secure and that the Manual Reset button is
6. ent owner Linden Shield Ltd WO 2003 106871 System Overview The system comprises a Detector or Detectors a Control Panel and a Shut Off device either a Valve or an Actuator The system has been designed to detect potentially harmful gas levels and provide visual and audible alarms and communicate the alarm to a Control Panel which in turn will close off the gas supply to prevent further increases in harmful gas levels if the shut off device is fitted The system can manage up to 3 detectors and guidance on location of different types of Detectors can be found below Detectors can be used independent of the other devices and will provide visual and audible alarm only INSTALLATION GUIDE FLOWTECH RECOMMENDS THAT ALL WIRING SHOULD BE UNDERTAKEN IN ACCORDANCE WITH THE LATEST WIRING REGULATIONS OF THE INSTITUTE OF ELECTRICAL ENGINEERS 1 Detector Location and fixing 1 1 Carbon Monoxide Detector s It is recommended that a CO Detector is located in every room in which a fuel burning appliance is used Due to the properties of Carbon Monoxide the detector should be positioned approximately 30 cm below the ceiling and at least 1 5m above the floor and a minimum of 1 5m away from any fuel burning appliance If one CO Detector is being fitted in the premises it is advisable to position the detector close to sleeping areas where it can he heard Do not install or position the detector outside the premises in damp humid or du
7. sty areas above a gas cooker gas boiler or fuel burning appliance in a drafty area e g close to a window or a doorway behind furniture curtains blinds in an area where the detector may be exposed to insecticide air cleaners glue hair spay or high levels of tobacco smoke Please do not install the detector if the room is being decorated or contains new furniture If it has already been installed please power off the detector and use a plastic bag to cover the detector to protect it Don t remove the plastic bag until the room is ventilated fully then power on the detector The warranty does not cover damage resulting from the above situations 1 2 Natural Gas Detector s It is recommended that a Natural Gas Detector is located approximately 30 cm below the ceiling and at least 1 5m above the floor and within 4 5 m of a gas burning appliance Do not install or position the detector outside the premises in damp humid or dusty areas above a gas cooker gas boiler or fuel burning appliance in a drafty area e g close to a window or a doorway where it can easily damaged 1 3 Fixing Detector s When you have chosen a location for your detector s ensure that the detector can be connected to the required power supply Do not connect it yet or fix to the wall Wireless communications links need to be checked during installation to ensure that the system operates fully 2 Control Pan
8. tic Current Alarm Current Static consumption Alarm Consumption Alarm Volume Working Environment Temperature Humidity Alarm Density Response Time lt 60 MA lt 50 MA lt 150 MA lt 1W lt 3W 85 db Wireless Range 0 60 C lt 97 RH 200m Open Ground Natural Gas 1000 5000PPM LPG 1000 10000PPM lt 30 seconds The response time of this alarm conforms with EN50194 6 3 Gas Lever Control Working Environment Temperature Humidity Rated Voltage Rated Current Rated Power Operating Power Valve Closing time Valve Opening time Torque Insulation resistance Gross Weight Dimensions 10 50 C lt 95 DC 12v Operating Voltage 100 mA Operating Current 1 2 W 0 24 W 10W 5 10 seconds 5 10 seconds 30 60 kg cm gt 20MQ 395g 100mm x 90mm x 70mm DC 6v 18v 20mA 1000mA Flowtech Controls Ltd 2009
9. tors have stabilised shown by the GREEN POWER Light being on constantly ON this coding can take place 4 5 On the top of the Control Panel is a button Press this button for 1 SECOND The RED TO CODE light will come on and the light will stay on for 30 SECONDS During this 30 second period an unique code will be sent to all detectors within range so that they can pair and be able to send signals to the Control Panel 4 6 To PAIR each Detector with your Control Panel PRESS the TEST button on each detector for 2 SECONDS DURING THIS 30 SECOND PERIOD WHILE THE RED TO CODE LIGHT ON THE CONTOL PANEL IS ON If the Detector has been successfully paired and is within range the Control Panel will make 3 BEEP SOUNDS Repeat until all detectors in your system have been checked Additional Detectors can be added to your system at any time To do this repeat steps 4 4 4 5 and 4 6 4 7 To clear all pairings press button on top of the Control Panel constantly for approximately 40 seconds The RED TO CODE LIGHT will be lit and then GO OFF 4 8 To test that the Control Panel can open and close the gas supply PRESS the TEST button on the Control Panel and your shut off device will close If your system uses the Actuator as the shut off device the gas supply can be re opened by pressing the RESET button on the Control Panel If the Valve option has been used in your system re open the Gas Supply be pulling down the Manual Reset