Home

Manual - B&B Electronics

image

Contents

1. par le minist re des Communications du Canada Limited Lifetime Warranty Effective for products of B amp B Electronics shipped on or after May 1 2013 B amp B Electronics warrants that each such product shall be free from defects in material and workmanship for its lifetime This limited lifetime warranty is applicable solely to the original user and is not transferable This warranty is expressly conditioned upon proper storage installation connection operation and maintenance of products in accordance with their written specifications Pursuant to the warranty within the warranty period B amp B Electronics at its option will 1 Replace the product with a functional equivalent 2 Repair the product or 3 Provide a partial refund of purchase price based on a depreciated value Products of other manufacturers sold by B amp B Electronics are not subject to any warranty or indemnity offered by B amp B Electronics but may be subject to the warranties of the other manufacturers Notwithstanding the foregoing under no circumstances shall B amp B Electronics have any warranty obligations or any other liability for i any defects resulting from wear and tear accident improper use by the buyer or use by any third party except in accordance with the written instructions or advice of the B amp B Electronics or the manufacturer of the products including without limitation surge and overvoltage conditions that exceed specified ratings
2. ii any products which have been adjusted modified or repaired by any party other than B amp B Electronics or iii any descriptions illustrations figures as to performance drawings and particulars of weights and dimensions contained in the B amp B Electronics catalogs price lists marketing materials or elsewhere since they are merely intended to represent a general idea of the products and do not form part of this price quote and do not constitute a warranty of any kind whether express or implied as to any of the B amp B Electronics products THE REPAIR OR REPLACEMENT OF THE DEFECTIVE ITEMS IN ACCORDANCE WITH THE EXPRESS WARRANTY SET FORTH ABOVE IS B amp B ELECTRONIC SOLE OBLIGATION UNDER THIS WARRANTY THE WARRANTY CONTAINED IN THIS SECTION SHALL EXTEND TO THE ORIGINAL USER ONLY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED AND ALL SUCH WARRANTIES AND INDEMNITIES ARE EXPRESSLY DISCLAIMED INCLUDING WITHOUT LIMITATION I THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY AND II ANY WARRANTY THAT THE PRODUCTS ARE DO NOT INFRINGE OR VIOLATE THE INTELLECTUAL PROPERTY RIGHTS OF ANY THIRD PARTY IN NO EVENT SHALL B amp B ELECTRONICS BE LIABLE FOR LOSS OF BUSINESS LOSS OF USE OR OF DATA INTERRUPTION OF BUSINESS LOST PROFITS OR GOODWILL OR OTHER SPECIAL INCIDENTAL EXEMPLARY OR CONSEQUENTIAL DAMAGES B amp B ELECTRONIC SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS WARRANTIES OR IN
3. the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the modules or stand alone units over any surface WARNING Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices 16 Safety Certifications UL CUL Listed to Safety of Information Technology Equipment including Electrical Business Equipment Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe 1 European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information abo
4. DEMNITIES MADE BY ANY OTHER PERSON INCLUDING WITHOUT LIMITATION EMPLOYEES DISTRIBUTORS RESELLERS OR DEALERS OF B amp B ELECTRONIC WHICH ARE INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE Table of Contents FCC Radio Frequency Interference Statement cece sees eeeeeteeeneeeees ii Limited Lifetime Warranty sen scccreneveesascsat nl titia to eo t EREA ii About TE TMCV AS S S STS coi Ak wectichtoethaetueh uae toca retndaaAad dits 1 Installating an IMCV DS3 E3 STS eicere re eE ee SEERE E 1 Configuration Instructions iiini iniisa nnii 1 REQUIFEMEMES srncie a aE E H 1 DIP Switches si anr a aa ee a a A a a e aa 3 LED ODOT at tests Se o E a r TE OA OEN 11 TrOUbIESHOGLNG Sainte A e EEA EE O EEE 12 Specifications e e E EE a a E E 13 B amp B Electronics Technical Support sssssssssssssssssissseisssssssssssrisssriessrissnrsssnesssrees 14 Fiber Optic Cleaning Guidelines ssssssssssssssssrttsssssstesssrtsssnresnnssrenesnrressnee 15 Electrostatic Discharge Precautions s sessissseisssesssssessiesstisssriesrrisssessssessress 16 Safety CrtifiGatiOns sx erinra eE EEEE LNN ERT E 17 About the iMcV DS3 E3 STS iMcV DS3 E3 STS is an SNMP manageable module which converts thin coax signals to single mode or multi mode fiber signals at a data rate of 45 Mbps DS3 34 Mbps E3 or 52 Mbps STS Each iMcV DS 3 E3 STS BNC FX module includes one pair of BNC connectors and one pair of ST or SC fiber optic
5. IMcV DS3 E3 STS Repeater Operation Manual Siss Mbps DS3 E3 STS a LPSK NO LAK B amp B ELECTRONICS Make The Right Connections FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment The use of non shielded I O cables may not guarantee compliance with FCC RFI limits This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique publi
6. _O ooo g m 3 o of ZH a i Fnnmuana T wr et 4567 8910 miu 3 FUNCTION RESULT D Default 1 2 OFF 1 2 ON Fiber 0 to 255 ft Transmit Data Source iView Configurable pCO 110 OFF Ooo eoo Feature Descriptions The iMcV DS3 E3 STS module includes several features that allow it to be configured for varying DS3 E3 STS based environments Loopback This switch enables or disables the loopback feature When this feature is enabled the data line Coax or Fiber set by the Loopback Type DIP Switch is looped back By default this feature is set to DISABLED This feature can be controlled by SNMP management software iView when the iMcV DS3 E3 STS module is installed in a managed chassis Loopback Type This switch controls which data line is looped back when the Loopback DIP Switch is enabled The data line loopback selection can be either Fiber Loopback or Coax Loopback By default this feature is set to COAX This feature can be controlled by SNMP management software iView when the iMcV DS3 E3 STS module is installed in a managed chassis Jitter Attenuation This switch selects the jitter attenuation location on the coax transceiver The jitter attenuation can be set on the transmit side or on the receive side of the coax transceiver Jitter attenuation is useful for decreasing jitter in the coax data stream This helps prevent data degradation caused by jitter Jitter attenuation i
7. connectors This module must be installed in either an SNMP manageable iMediaChassis chassis or an unmanaged MediaChassis chassis Also available for single strand fiber iMcV DS 3 E3 STS BNC SSFX includes one pair of BNC connectors and an SC fiber optic connector iMcV D 3 E3 STS BNC SSFX modules allow two wavelengths for example 1310 nm and 1550 nm to share one fiber strand essentially doubling the capacity of installed fiber iMcV DS3 E3 STS modules must be deployed in pairs one at each end of a conversion The data transmitted on the fiber ports can only be received and interpreted by the receive fiber of another iMcV DS3 E3 STS The single strand versions must have opposite transmit and receive wavelengths for example one that transmits at 1310 nm must be paired with another that receives at 1550 nm Installating an iMcV DS3 E3 STS iMcV DS3 E3 STS modules can be installed in any iMediaChassis MediaChassis or 1E MediaChassis series remote modules can also be installed in any unmanaged MediaChassis series or managed iMediaChassis series Each module requires one slot in the chassis To install a module remove the blank brackets covering the slots where the module is to be installed if present by removing the screws on the outside edges of the bracket Slide the module into the chassis card guides until the module is securely seated in the connector Secure the module to the chassis by tightening the captive screw Save an
8. h helps determine whether a connection is still valid Remote loopback tests isolate problems on the coax run between an iMcV DS3 E3 STS module and the connected device while local loopback tests can isolate problems on the fiber connected to the module The following illustrations show a typical progression of loopback tests i e starting by checking the coax segment at the local side then the coax segment at the remote side etc Coax Loopback on Local iMcV DS3 E3 STS Central Office Customer iMcV DS3 E3 STS iMcV DS3 E3 STS Coax Loopback on Remote iMcV DS3 E3 STS None Fiber Coax Loopback Coax a eg iMcV DS3 E3 STS iMcV DS3 E3 STS Fiber Loopback on Local iMcV DS3 E3 STS Central Office Customer iMcV DS3 E3 STS iMcV DS3 E3 STS Fiber Loopback on Remote iMcV DS3 E3 STS Customer iMcV DS3 E3 STS iMcV DS3 E3 STS Pseudorandom Bit Sequence PRBS Testing To test using Pseudorandom Bit Sequence configure the iMcV DS3 E3 STS modules for No Loopback then configure the Transmit Data Source to Transmit 9 Pseudorandom Bit Sequence Configure the local device for loopback conduct the test then check the PBEO LED to verify errors were not received Refer to the LED section for more information Pseudo Random Bit Sequence Customer iMcV DS3 E3 STS iMcV DS3 E3 STS 10 LED Operation The iMcV DS3 E3 STS module features several diagnostic LEDs per port The LED functions a
9. mote Unit This option allows the user to enable Remote Unit on the module The Remote Unit feature is designed to work only as the remote module of the Local Remote pair in the required Master Slave configuration With Remote Unit enabled the user can easily perform the following e Test the line integrity of the remote copper port e Use the Local unit to configure all SNMP configurable features for both units e Use the Local unit to download firmware for both units Refer to the Module LED Functions section for more information By default this feature is set to Disabled This feature can only be selected by setting the DIP Switches manually Loopback Testing The iMcV DS3 E3 STS includes two loopback test modes Coax Loopback and Fiber Loopback The following illustrations show the path that a signal takes in each of the loopback test modes Coax Loopback Fiber Loopback ih Mbps Site Mbps DS3 E3 STS DS3 E3 STS LPBK _NOLNK LPBK NO LNK paeo 4 PBEO eooo eR m u eee Nn RCV A lt q K xm xm a eT er I Rev n Na tall Oeil sym Each loopback performs the following e Redirects the incoming signal back out to the origin while continuing to transmit downstream e Blocks downstream data from arriving on the looped data line 8 Loopback testing is useful for troubleshooting problems with network connections should they occur Looping received data back onto the transmit pat
10. nit Enabled only at the REMOTE end Remote 1 10 OFF Remote Unit Disabled only at the LOCAL end Host iView2 Management Software iView is the B amp B Electronics management software designed specifically for the B amp B Electronics iMcV family of modules It features a GUI and gives network managers the ability to monitor and control the manageable B amp B Electronics products iView is available in several versions including WebServer version 3 0 and can also function as a snap in module for HP OpenView Network Node Manager and other third party SNMP Management software iView supports the following platforms e Windows 2000 e Windows XP e Windows Vista e Windows 7 Please see the SNMP Management Module installation guide for software configuration options Unmanaged Modules Before installing the module in an unmanaged chassis including IE MediaChassis series and MediaChassis series manually configure all of the desired DIP Switch selectable features In an unmanaged configuration none of the DIP Switch settings can be overridden by software DIP Switches The iMcV DS3 E3 STS DIP Switches are located on 1 and 2 on the PCB The S2 DIP Switches are factory configured and must not be moved The S1 DIP Switches provide control over the available iMcV DS3 E3 STS features The location of the 1 DIP Switches is displayed in the following diagram hes ooo 3 m ag al Kk z 000 g nes o
11. re as follows LPBK NO LNK PBEO FA NO LNK RM SYM LEDs Next to Coax BNC Port Glows green when module is in a Loopback mode Glows green when a link is NOT established When Transmit Data Source is set to Pseudo random Bit Sequence this LED will glow yellow when iMcV DS3 E3 STS receives a Pseudorandom Bit Sequence with errors The LED stays off when the converter receives a Pseudorandom Bit Sequence without errors When Transmit Data Source is set to any other configuration besides Pseudorandom Bit Sequence this LED remains off as well LEDs Next to Fiber Optic Port Glows green when FiberAlert is enabled Glows green when a link is NOT established Glows green on the Remote Unit when set to DSW S1 10 Glows green on the Local unit when it has discovered a Remote management with Remote Unit enabled Glows yellow when a FX symbol error has occurred 1 84 Mbps DS3 E3 STS LPBK4 NOLNK al PBEO LIII 11 Troubleshooting General Troubleshooting e During installation first test the fiber and BNC connections with all troubleshooting features disabled then enable these features if desired just before final installation This will reduce the features interference with testing e When working with units where the features cannot be disabled you must establish BOTH your BNC and fiber connections the NO LNK LEDs should not be lit ie NO LNK LED not lit good connection NO LNK LED li
12. s always enabled By default this feature is set to TRANSMIT This feature can be controlled by SNMP management software iView when the iMcV DS3 E3 STS module is installed in a managed chassis FiberAlert This switch enables or disables the FiberAlert feature This feature must only be enabled on the remote end of a Host Remote iMcV DS3 E3 STS pair The FiberAlert feature uses the iMcV DS3 E3 STS module LEDs to indicate that a loss of one strand of fiber has occurred When a strand becomes unavailable the iMcV DS3 E3 STS module at the receiver end detects the loss of the link The module then responds by stopping the transmission of the data and link signal until a new signal or link pulse is received on the strand The result is that the NO LNK LED on both sides of the fiber connection will light up to indicate the presence of a fault somewhere in the fiber loop By using FiberAlert a local site administrator can quickly determine wh3ere a fiber cable fault is located By default this feature is set to DISABLED This feature can be controlled by SNMP management software iView when the iMcV DS3 E3 STS module is installed in a managed chassis WARNING Enabling FiberAlert on both of the iMcV DS3 E3 STS modules will cause them both to stop transmitting unrecoverably when a fault occurs This feature is designed to only be enabled on the Remote iMcV DS3 E3 STS module Transmit LIU Waveshape Line Build Out This swi
13. t problem e To test a media converter by itself first make sure you have an appropriate fiber patch cable then follow these steps to test 1 Connect the media converter to the BNC device with a coax cable 2 Loop a single strand of fiber from the transmit port to the receive port of your media converter 3 Verify that you have a valid connection for both the BNC and fiber ports on your media converter e If there is trouble with link connectivity make sure the connection is made using 75W Coax cable NOTE iMcV DS3 E3 STS Repeater modules cannot be connected iMcV DS3 E3 STS LineTerm modules successfully 12 Specifications Power Consumption Typical 0 550 Amps 5 V Operating Temperature 32 F to 122 F 0 C to 50 C Storage Temperature O F to 160 F 20 C to 70 C Humidity 5 to 95 non condensing 0 to 10 000 ft altitude Dimensions 4 19 x 78 x 2 75 106 4 mm x 19 81 mm x 69 85 mm 13 B amp B Electronics Technical Support Tel 800 346 3119 in the U S and Canada Monday Friday 7 00am 7 00pm CST 353 91 792444 Europe Monday through Friday 8 00am 5 00pm GMT Fax 815 433 5109 U S and Canada 353 91 7924455 Europe E Mail support bb elec com U S and Canada techsupport bb elec com Europe Web www bb elec com 14 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by par
14. tch selects the optimal transmit waveshape for the line build out distance on the coax line The transmit waveshape can be set for a distance of either 0 to 255 feet or over 255 feet This feature corrects problems related to cabling i e cross talk electromagnetic interference etc Improperly setting this switch will cause signal degradation By default this feature is set to gt 255 FEET This feature can be controlled by SNMP management software iView when the iMcV DS3 E3 STS module is installed in a managed chassis Transmit Data Source These switches select the transmit mode used by the iMcV DS3 E3 STS module The transmit modes that can be selected include the following Standard data e Unframed All Ones diagnostic e Alternating Ones and Zeros diagnostic e Pseudorandom bit sequence diagnostic These standard Telco transmission pattern modes are provided to help diagnose transmission errors in the line By default this feature is set to STANDARD DATA This feature can be controlled by SNMP management software iView when the iMcV DS3 E3 STS module is installed in a managed chassis DS3 E3 and STS Selection This switch selects the data rate to use on the coax line The data rate selections available include the following e 45 Mbps DS3 e 34 Mbps E3 e 52 Mbps STS By default this feature is set to 45 Mbps DS3 This feature can only be selected by setting the DIP Switches manually Re
15. ticles of dirt or dust which can obstruct the optic path and cause performance degradation Good system performance requires clean optics and connector ferrules 1 Use fiber patch cords or connectors if you terminate your own fiber only from a reputable supplier low quality components can cause many hard to diagnose problems in an installation Dust caps are installed at B amp B Electronics to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber cable to the device Should it be necessary to disconnect the fiber device reinstall the protective dust caps Store spare caps in a dust free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics If you suspect that the optics have been contaminated alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt 15 Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective packaging until ready to install 2 Wear an ESD wrist grounding strap before handling any module or component If the wrist strap is not available maintain grounded contact with
16. ut proper disposal please contact local authorities waste disposal services or the point of purchase for this equipment S REGISTERED RoHS B B amp B ELECTRONICS Make The Right Connections International Headquarters B amp B Electronics 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Email support bb elec com Website www bb elec com European Headquarters B amp B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 79244S5 Email techSupport bb elec com Website www bb elec com The information in this document is subject to change without notice B amp B Electronics assumes no responsibility for any errors that may appear in this document iMcV DS3 E3 STS Repeater is a trademark of B amp B Electronics Other brands or product names may be trademarks and are the property of their respective companies Document Number 50 80301 00 A5 October 2013
17. y blanks removed during installation for future use Configuration Instructions Proper configuration of the iMcV DS3 E3 STS is required for maximum performance and reliability The following sections describe the prerequisites and the configurations available for both managed and unmanaged modules Requirements The iMcV DS3 E3 STS is designed to conform to many DS3 E3 STS based environments Make sure that all of the relevant information about the expected installation environment is available before configuring the module This information includes the following e Distance of the coax run Distance of the fiber run Troubleshooting requirements Managed Modules To manage iMcV DS3 E3 STS modules an SNMP agent must be present the iMediaChassis requires an SNMP management module For a managed environment first manually configure all of the desired DIP Switch selectable features to match what will be configured through the SNMP Management Module Use the Graphical User Interface GUI to enable features by using the iView SNMP management software In a managed chassis the software settings take priority over the SNMP enabled feature DIP Switch settings Make sure that the software settings match the desired configuration requirements for the installation Before installing the modules they must be configured for Host Remote via the DIP Switches The Master Slave condition requires this configuration 1 10 ON Remote U

Download Pdf Manuals

image

Related Search

Related Contents

Sony BDP-S390  hidescan4プレスリリースのダウンロード    エコキュート 使いこなし術  Des bords de mer au cœur des terres  CIRCULAIRE N° DGOS/PF2/2011/150 du 19  StarTech.com 6 ft Cisco Console Rollover Cable - RJ45 Ethernet M/M    

Copyright © All rights reserved.
Failed to retrieve file