1. MinMax memory Timestamps clear memory WWW and security Security features can be enabled by the Security enabled option When security is enabled it is necessary to set administrator password This password will be required for device settings When secured access is required even to actual values reading it is possible to enable User account only for viewing Port of the www setver can be changed from the default value 80 using filed WWW port Web pages with actual values are refreshed according to Web refresh interval field smin Settings WWW and Security Security General Configuration of the secure access to the device Administrator password must be inserted if security is General device settings enabled Administrator password is used for device configuration User password is used only for measured values viewing Network Basic settings of the network interface Secu rity ena bled Oo e Pg Web server s Configuration of the embedded web server Web server can be disabled by TSensor software d Web server enabled Pad WWW port 80 Time Synchronization with NTP server n Web refresh interval 10 Sec WWW and Security Web server and Security configuration Apply settings Cancel changes MinMax memory Timestamps clear memory Maintenance Factory defaults info etc 18 IE SNC P8x52 03 Setup using TSensor software TSensor software is an alternative to web configuration Some less important pa
2. For each measurement channel is possible to set upper and lower limits time delay for alarm activation and hysteresis for alarm clearing Pittman Settings Alarm limits Configuration of the alarm limits The safe range is between high and low limit Alarm condition occurs General while measured value is out of the safe range for selected time delay Alarm is cleared if measured value General device settings returns to safe range with hysteresis Channel 1 limits Network Channel name Channel 1 Basic settings of the network interface Current value 22 8 0C User adjustment no High limit 0C Low limit C Hysteresis C Time delay sec 50 0 0 0 1 0 30 Channels General settings of the channels Channel 2 limits Channel name Channel 2 Current value 48 7 RH d User adjustment no o E High limit RH Low limit RH Hysteresis RH Time delay sec gt 50 0 0 0 1 0 30 MinMax memory Timestamps clear memory Apply settings Cancel changes Maintenance Factory defaults info etc Example of setting the limit to the upper alarm limit temp limit high hysteresis temp Time delay time In Point 1 the temperature exceeded the limit From this time the time delay is counting Because at point 2 the temperature dropped below the limit value before the time delay expired alarm was not set In Point 3 the temperature has risen over limit again During the time delay the
3. Voltage level for LOW lt 1 0V Voltage level for HIGH gt 2 5V Internal resistivity of the voltage source 2kQ Input voltage range 0 to 30V Reverse polarity protection yes RJ45 connector 10Base T 100Base TX Ethernet Auto Sensing Recommended Connector Cable 33 IE SNC P8x52 03 for industrial use is recommended Cat5e STP cable in less demanding applications can be replaced by Cat5 cable maximum cable length 100m Supported protocols TCP IP UDP IP ARP ICMP DHCP TFTP DNS HTTP SMTP SNMPv1 ModbusTCP SNTP SOAPv1 1 Syslog SMTP protocol SMTP authentication AUTH LOGIN Encryption SSL TLS STARTTLS is not supported Supported web browsers Internet Explorer 9 and later Mozilla Firefox 30 and later Google Chrome 36 and later Opera 21 and later Device should be also compatible with other browsers Functionality wasn t tested with other web browsers Recommended minimum screen resolution 1024 x 768 Memory 1000 values for each channel inside non backup RAM memory 100 values in alarm events log inside non backup RAM memory 100 values in system events log inside non backup RAM memory Case material ABS Mounting the device With two holes at the bottom of the unit Weight P8552 140g P8652 145g EMC EN 61326 1 EN 55011 Operating terms Temperature and humidity range in case with electronic 20 C to 60 C 0 to 100 RH no condensation Temperature range of recommended probe DSTR1
4. address MAC address EA 168 1 47 00 80 43 93 51 DF DHCP Set IP address to AAP table only X conc gateway may not be entered if you want to use the device only in local network If you set the same IP address which is already used the device will not work correctly and there will be collisions on the network If the device detects a collision of IP address then reboot is performed automatically after changing IP address device is restarted and new IP address is assigned Restart of the device takes about 10 seconds find the connected probes and change binary input type on webpages of by TSensor if necessary IE SNC P8x52 03 Checking functions The last step is to check measured values on the device website Enter the device IP address into address bar of the web browser If the default IP address was not changed then insert http 192 168 1 213 Displayed web page lists actual measured values If the web pages are disabled you can see text Access denied If the measured value exceeds the measurement range or probe is not correctly installed then is shown Error message If the channel is switched off the web site displayed n a instead of the value IE SNC P8x52 03 Device setup This chapter describes basic device configuration There is a description of settings using web interface Setup using web interface Device can be setup using web interface or TSensor software Web interface can be managed by the
5. available devices I cannot connect to the device In search window is only IP and MAC address displayed Other details are marked N A This problem occurs if IP address of the device is set to another network Select the window Find device in TSensor software and press Change IP address Follow the software instructions To assign IP address automatically using DHCP server set the device IP address to 0 0 0 0 Device IP address is not displayed in window Find device In TSensor software menu press Help My device was not found in window Find device Follow the software instructions MAC address of the device can be found on product label The device is not found even after manually setting MAC address This problem occuts especially in cases when the IP address of the device belongs to another netwotk and also Subnet mask or Gateway are incorrect In this case is DHCP server in the network necessary In TSensor software menu press Help My device was not found in window Find device As new IP address set 0 0 0 0 Follow the software instructions An alternative is to reset device to factory defaults using factory defaults button 29 IE SNC P8x52 03 Error or n a is displayed instead the measured value Value n a is shown a shortly after device restart If the error code or n a is displayed permanently check if the probes are connected to device correctly Make sure that probes are not damaged and inside operating range T
6. http www w3 org 2001 XMLSchema gt lt soap Body gt lt InsertP8xxxBinInSample xmlns http cometsystem cz schemas soapP8xxxBinIn xsd gt lt name gt Web Sensor lt name gt lt sn gt 14969090 lt sn gt lt tmr gt 10 lt tmr gt lt kind gt 4360 lt kind gt lt c i 1 gt lt e gt 1 lt e gt lt n gt freezer lt n gt lt u gt C lt u gt lt p gt 1 lt p gt lt v gt 10 4 lt v gt lt a gt no lt a gt lt h gt 5 0 lt h gt lt 1 gt 20 0 lt 1 gt c lt c i 5 gt lt e gt 0 lt e gt lt n gt Channel 5 lt n gt lt u gt n a lt u gt lt p gt 1 lt p gt lt v gt 11000 lt v gt lt a gt no lt a gt lt h gt 50 0 lt h gt lt 1 gt 0 0 lt 1 gt c lt b i 6 gt lt e gt 1 lt e gt lt n gt Door 1 lt n gt lt b0 gt open lt b0 gt lt b1 gt closed lt b1 gt lt v gt 0 lt v gt lt a gt no lt a gt lt b gt lt b i 8 gt lt e gt 1 lt e gt lt n gt power lt n gt lt b0 gt fail lt b0 gt lt b1 gt 0K lt b1 gt lt v gt 0 lt v gt 26 IE SNC P8x52 03 lt a gt ac lt a gt lt b gt lt InsertP8xxxBinInSample gt lt soap Body gt lt soap Envelope gt Element Description General lt name gt Device description elements sn Contains the device serial number an eight digit number tmr SOAP sending interval sec kind Device type identification number code
7. web browser Main page will be shown when you insert device address into address bar of your web browser There you find actual measured values Page with history graphs is shown when you click to tile with actual values Access to device setup is possible via tile Settings C Web Sensor d 192 162 1213 Web Sensor Time 15 57 06 2015 02 17 s n 14942068 Channel 1 Channel 2 History Events CSV CSV 26 1 C 30 9 RH dot file dot file alarm none alarm low History Events min 26 1 C min 30 79 RH max 26 3 C max 31 49 6RH CSV CSV comma file comma file Channel 3 76 1 F alarm none Events min 75 7 F max 76 3 F viewer Door Flood sensor Settings closed normal alarm none alarm none Power supply off alarm none Copyright 2015 Comet system s r o All rights reserved 10 IE SNC P8x52 03 General Device name can be changed using item Device name Measured values are stored into memory according History storage interval field After changing of this interval all history values will be cleared Changes must be confirmed by Apply settings button Pittman Settings General General device settings Device name can be changed to user specified name History graphs and tables General will be cleared after changing history storage interval General device settings Device name Web Sensor Network s Basic settings of the network interface Histo ry sto rage interval 1 Min v Pa
8. 17 0x9C51 Channel 3 delay ulnt 40018 0x9C52 Channel 4 temperature or humidity Int 10 40019 0x9C53 Channel 4 alarm status Ascii 40020 0x9C54 Channel 4 upper limit Int 10 40021 0x9C55 Channel 4 lower limit Int 10 40022 0x9C56 Channel 4 hysteresis Int 10 40023 0x9C57 Channel 4 delay ulnt Description Int 10 registry is in format integer 10 16 bits ulnt registry range is 0 65535 Ascii character BCD registry is coded as BCD n a item is not defined should be read Possible alarm states Ascii no no alarm lo value is lower than set limit hi value is higher than set limit 25 IE SNC P8x52 03 SOAP The device allows you to send currently measured values via SOAP v1 1 protocol The device sends values in XML format to the web server The advantage of this protocol is that communication is initialized by the device side Due to it is not necessary use port forwarding If the SOAP message cannot be delivered warning message via SNMP Trap or Syslog protocol is sent The file with the XSD schema can be downloaded from http cometsystem cz schemas soapP8xxxBinIn xsd SOAP message example Host 192 168 1 132 Content Type text xml charset utf 8 Content Length 1323 SOAPAction http cometsystem cz schemas soapP8xxxBinIn xsd InsertP8xxxBinInSample xml version 1 0 encoding utf 8 soap Envelope xmlns soap http schemas xmlsoap org soap envelope xmlns xsi http www w3 org 2001 XMLSchema instance xmlns xsd
9. 62 C 30 C to 80 C Temperature range of probe DSTGL40 C 30 C to 80 C 34 IE SNC P8x52 03 Temperature range of probe DSTG8 C 50 C to 100 C Temperature range of probe DSRH 0 C to 50 C Working position arbitrary End of operation Disconnect the device and dispose it according to current legislation for dealing with electronic equipment Electronic devices must be professionally destroyed in accordance with EU Directive 2002 96 ES of 27th January 2003 Technical support and service Technical support and setvice is provided by distributor Contact is included in warranty certificate Preventive maintenance Make sure the cables and probes are not damaged periodically Recommended calibration interval is 2 years Recommended calibration interval for device with humidity probe DSRH is 1 year 35 IE SNC P8x52 03 Optional accessories This chapter contains list of optional accessories which can be ordered by extra cost Manufacturer recommends using only original accessories Temperature probe DSTR162 C Temperature probe 30 to 80 C with a digital sensor DS18B20 and with Cinch connector for Web Sensor P8552 and Web Sensor P8652 Accuracy 0 5 C from 10 to 80 C 2 C below 10 C Length of the plastic case 25mm diameter 10mm Guaranteed watertight IP67 sensor connected to PVC cable with lengths 1 2 5 or 10m Temperature probe DSTGL40 C Temperature probe 30 to 80 C with a digital s
10. 8 1 132 IP address of the Trap recipient 2 192 168 1 200 Protocols UI M IP address of the Trap recipient 3 0 0 0 0 SNMP 1 SNMPv1 protocol and SNMP Traps Apply settings Cancel changes Time Synchronization with NTP server WWW and Security Web server and Security configuration 17 IE SNC P8x52 03 Time Time synchronization with SNTP server can be enabled by Time synchronization enabled option IP address of the SNTP is necessary to set into SNTP server IP address item List of free NTP servers is available at www pool ntp org en SNTP time is synchronized at UTC format and due to be necessary set corresponding time offset GMT offset min Time is synchronized every 24 hours by default Option NTP synchronization every hour decrease this synchronization interval to one hour Eres Settings Time Time can be synchronized according the SNTP server To correct time is necessary set GMT offset of your time General zone Time synchronisation is required for timestamps inside CSV files General device settings Time synchronised with server yes at 15 48 10 2015 02 17 Network sod aeaa Sf Ea onsen Time synchronization enabled 7 RM SNTP server IP address 192 168 1 2 ve GMT offset min 60 H NTP synchronization every hour e SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Security Web server and Security configuration Apply settings Cancel changes
11. COMET SYSTEM www cometsystem com Web Sensor P8552 with binary inputs PoE Web Sensor P8652 with binary inputs USER GUIDE IE SNC P8x52 03 O Copyright COMET System s r o Is prohibited to copy and make any changes in this manual without explicit agreement of company COMET System s r o All rights reserved COMET System s r o makes constant development and improvement of their products Manufacturer reserves the right to make technical changes to the device without previous notice Misprints reserved Manufacturer is not responsible for damages caused by using the device in conflict with this manual To damages caused by using the device in conflict with this manual cannot be provide free repairs during the warranty period This user manual describes device with firmware version 4 5 8 x IE SNC P8x52 03 T able of contents lentas 4 Genetal safety Tales M 4 Device description and important notices tentent 5 Gette Started sts 6 Whats needed for opetatlon sorier na ea R AE ri Pere es p ree idit 6 Mounting the sao e 6 Device dac M H i CHECKING FUNCHONS MD 9 Device SetuP NC H TQ 10 Setup usine web Jntetface x e tee RH Depp e ae REOR e REED e ES TERE EEEN 10 Setup using Sensor S
12. Device Code DEC P8652 4360 P8552 4361 Channel lt e gt Information about enabled disabled channel 1 enabled 0 elements disabled lt n gt Name of channel lt u gt Channel unit C F or RH In case of error n a text is shown lt p gt Count of the decimal places Always 1 lt v gt Actual measured value a decimal part of number is separated by a dot Error on channel has number 11000 or lower lt a gt Alarm state where no no alarm hi high alarm lo low alarm lt h gt Preset high limit on channel lt I gt Preset low limit on channel BIN lt e gt Information about enabled disabled binary input 1 enabled 0 input disabled elements n Name of binaty input lt b0 gt Description for binary input state 0 lt b1 gt Description for binary input state 1 lt v gt Current state of binary input 0 1 or 11000 lt a gt Alarm state where no no alarm ac active alarm Examples of the web service for incoming SOAP messages from Web Sensor P8652 and P8552 for net and PHP are available at device webpages library page 27 IE SNC P8x52 03 Syslog The device allows sending text message to selected Syslog server Events are send using UDP protocol on port 514 Syslog protocol implantation is according to RFC5424 and REC5426 Events when Syslog messages are send Text Event Sensor fw 4 5 8 x Reset of the device NTP synchronization error NTP synchronizat
13. NS is required to set DNS server IP address SMTP authentication is supported but SSL STARTTLS not Standard SMTP port 25 is used by default SMTP port can be changed Contact your network administrator to obtain configuration parametets of your SMTP server E mail sent by the device cannot be answered 22 IE SNC P8x52 03 SNMP Using SNMP protocol you can read actual measured values alarm status and alarm parameters Via SNMP protocol is also possible to get last 1000 measured values from history table Writing via SNMP protocol is not supported It is supported SNMPv1 protocol version only SNMP used UDP port 161 OID keys description can be found in the MIB table which can be obtained from device website or from your distributor The password for reading is factory set to public Filed System location OID 1 3 6 1 2 1 1 6 sysLocation is blank by default The changes can be made using web interface Some SNMP manager software requires add 0 at end of OID key e g 1 3 6 1 4 1 22626 1 5 2 1 2 0 OID keys 1 3 6 1 4 1 22626 1 5 1 Description Device information 1 3 6 1 4 1 22626 1 5 1 1 Device name String 1 3 6 1 4 1 22626 1 5 1 2 Serial number String 1 3 6 1 4 1 22626 1 5 1 3 Device type Integer 1 3 6 1 4 1 22626 1 5 2 ch Measured value where ch 1 channel 1 etc 1 3 6 1 4 1 22626 1 5 2 ch 1 Channel name String 1 3 6 1 4 1 22626 1 5 2 ch 2 Actual value text Str
14. OMware E 19 Factory detaults e 19 COMMUNICATION PLrOtOCOIS m M 22 S E 22 SMI P sending e mails H MM 22 ui 23 hunter C denasvotdonsnsndgsnensnseses 24 Nar 26 Syd S 28 Se A E EEEE E E E tud ustedes diente siis oit 28 Brei dierejud P 29 forgot the device P address eerie rentrer tee ie HYPE SERE Ve NEEE E E EEEE EEE 29 I cannot connect to the device eere teet teret here re tti Eb use eb eR Eas en SEES eL 29 Error or n a is displayed instead the measured value eene 30 Error2 is displayed on all channels instead the measured value sss 30 Binary inputs not show the correct values 30 Lforgot the password for setup seas eet t E RH D tra t ore ne Dare A LEM KRERS 30 Pactory detauilts isi t 30 Technical specifications EM 32 IDimnenstoOnSne tense unes ur uncus ise ite 32 basic patamcters 2 2cnicnnkdeak intend EEn ea TETAAN EAE 32 COperatino terms cases teet Brent ee eae arenes mte ee 34 End Of OPSratlOny e 35 Technical support and Service ssssicssiessteseiessi
15. ble the device It s forbidden to use the device without the cover Inside the device can be a dangerous voltage and may be risk of electric shock Use only the approptiate power supply adapter according to manufacturer specifications and approved according to relevant standards Make sure that the adapter does not have damaged cables or covers Connect the device only to network parts approved according to relevant standards Where power ovet Ethernet is used the network infrastructure must be compatible with IEEE 802 3af standard Connect and disconnect the device properly Don t connect or disconnect Ethernet cable binary inputs or probes if the device is powered Do not connect higher voltage to binary inputs than is allowed IE SNC P8x52 03 The device may be installed only in prescribed areas Never expose the device to higher or lower temperatures than is allowed The device has not improved resistance to moisture Protect it from dripping or splashing water and do not use at areas with condensation Don t use device in potentially explosive environments Don t stress the device mechanically Device description and important notices This chapter contains information about basic features Also there are important notices concerning to functional safety Values from the device can be read using an Ethernet connection The following formats are supported e Web pages with user changeable look and XML files e Modbus TCP pro
16. ctory set the IP address to 192 168 1 213 This address must be changed according to information from the previous point When you installing several new devices connect them to the netwotk one after another connect temperature and humidity probes to Web Sensor connect binary inputs of the device connect the Ethernet connector if the power over Ethernet PoE is not used connect the power adapter 5V 250mA LEDs on LAN connector should blink after connecting the power Web Sensor connection power supply adapter Power over Ethernet Binary inputs Voltage contact GND Dry contact GND Device settings run configuration software TSensor on your PC switch to an Ethernet communication interface IE SNC P8x52 03 press button Find device Communication interface Device settings d Savica cabi SEI IP address 192168 1 213 C Serial R5232 Find Device C Serial R5485 X Cancel the window shows all available devices on your network IPaddress MAC address 192 168 1 47 _ 00 80 A3 33 51 DF__ 4 5 7 00__ P8652 Q Search Help My device wasn t found x Cancel Change IP click to Change IP address to set new address according to network administrator instructions If your device is not listed then click Help My device wasn t found Then follow the instructions MAC address is on product label The device is factory set to IP 192 168 1 213 P
17. d Apply settings Cancel changes MinMax memory Timestamps clear memory Maintenance Factory defaults info etc Network Network parameters can be obtain automatically from DHCP server using option Obtain an IP address automatically Static IP address is configurable via field IP address It is not necessary setup Default gateway while you use device inside one subnet only DNS server IP is required to set for proper function of DNS Option Standard subnet mask sets network mask automatically according A B or C netwotk class Subnet mask field must be set manually when network with non standard range is used Periodic restart interval enables to restart device after selected time since device start Dittman Settings Network Basic settings of the network interface IP address can be set as either static or obtained automatically General by the DHCP server After saving the setting device will be rebooted automatically Before changing IP General device settings address please contact your network administrator D i Basic settings of the network interface IP address 192 168 1 213 Alarm limits Configuration of the alarm limits Default gateway 192 168 1 1 2d DNS server IP 192 168 1 1 iS Standard subnet mask Oo d Subnet mask 255 255 255 0 LALER TEID ts Periodic restart interval off x Maintenance Factory defaults info etc Apply settings Cancel changes 11 IE SNC P8x52 03 Alarm limits
18. device 6 0 Testing Trap 6 1 NTP synchronization error 6 2 SMTP server login error 6 3 E mail sendin SMTP authentication error 6 4 8 Some error occurred during SMTP communication error 6 5 TCP connection to server cannot be opened 6 6 SMTP server DNS error 6 7 SOAP file not found inside web memory 6 8 SOAP message MAC address can t be obtained from address 6 9 sending error TCP connection to server cannot be opened 6 10 Wrong response code from the SOAP server 6 11 6 15 Upper alarm on channel 6 21 6 25 Lower alarm on channel 6 31 6 35 Clearing alarm on channel 6 41 6 45 Measuting error 6 51 6 55 Alarm on binary input 6 61 6 65 Clearing alarm on binary input Modbus TCP Device supports Modbus protocol for communication with SCADA systems Device use Modbus TCP protocol TCP port is set to 502 by default Port can be changed using web interface Only two Modbus clients can be connected to device at one moment Modbus device address Unit Identifier can be arbitrary Modbus write command is not supported Specification and description of the Modbus protocol is free to download on www modbus org Supported Modbus commands functions Command Code Description Read Holding Register s 0x03 Read 16b register s Read Input Register s 0x04 Read 16b register s Modbus device registers Address could be by 1 higher depending on type used communication library 24 IE SNC P8
19. ensor DS18B20 and with Cinch connector Accuracy 0 5 C from 10 to 80 C 2 C below 10 C Stainless steel case with length 40mm diameter 5 7mm Stainless steel type 17240 Guaranteed watertight IP67 sensor connected to PVC cable with lengths 1 2 5 or 10m Temperature probe DSTG8 C Temperature probe 50 to 100 C with a digital sensor DS18B20 and with Cinch connector Maximum temperature of the probe is 125 C Probe accuracy 0 5 C from 10 to 85 C else 2 C Steal steel case with length 40mm diameter 5 7mm Stainless steel type 17240 Guaranteed watertight IP67 sensor connected to silicone cable with lengths 1 2 5 or 10m Humidity probe DSRH DSRH is a relative humidity probe with Cinch connector Relative humidity accuracy is 3 5 RH from 1096 9099 RH at 25 C Temperature measuring accuracy is 2 C Operating temperature range is 0 to 50 C Probe length 88mm diameter 18mm connected to PVC cable with lengths 1 2 or 5m Humidity temperature probe DSRH C DSRH C is compact probe for measurement of relative humidity and temperature Relative humidity accuracy is 3 5 RH from 10 90 RH at 25 C Temperature measuring accuracy is 0 5 C Operating temperature range is 0 to 50 C Probe length is 100mm and diameter is 14mm Probe is designed to be directly mounted to device without cable 36 IE SNC P8x52 03 Power supply Adapter A1825 Power supply adapter with CEE 7 plug 100 240V 50 60Hz 5V DC 1 2A Adapte
20. erface Alarm limits Configuration of the alarm limits Channels General settings of the channels BIN Inputs Binary inputs settii i SOAP protocol Setup SOAP protocol for database system Email Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPvi protocol and SNMP Traps Time Synchronization with NTP server WWW and Security Web server and Security configuration MinMax memory Timestamps clear memory Maintenance Factory defaults info etc Inputs Binary inputs settings Alarms on binary inputs are evaluated by the selected alarm level Alarm on and time delay for alarm Dry contact option should be selected for door contacts and sensors with relay output Voltage contact is available for sensors with voltage output like a AC voltage detector SP008 Binary Input 1 Enabled Closed state description Open state description Time delay for alarm sec Alarm on Input type Binary Input 2 O Enabled Binary Input 3 Enabled High voltage description Low voltage description Time delay for alarm sec Alarm on Input type Door closed open 2 Open state v Dry contact iv BIN input 2 Power supply ok fail 2 Low voltage Voltage contact iy Apply settings Cancel changes 14 IE SNC P8x52 03 SOAP protocol SOAP protocol can be enabled by option SOAP protocol enabled Destination SOAP server can be set via SOAP server address For
21. han perform new search of probes using web interface Error2 is displayed on all channels instead the measured value Error2 indicates short circuit of measurement bus Check if correct probes are connected Probes Pt100 Pt1000 Ni100 Ni1000 cannot be used with this device Make sure that cables of probes are not damaged Binary inputs not show the correct values Probably is selected wrong type of binary input Please switch input type on web interface Option Dry contact should be used for potential less inputs like a door contact Switch to Voltage contact in case of using AC voltage detector SP008 I forgot the password for setup Please reset device to factory defaults Procedure is described at following point Factory defaults This procedure restore device to factory settings including network parameters IP address Subnet mask etc For factory defaults follow these steps e disconnect the power supply power adapter or RJ45 connector if PoE is used e use something with thin tipped e g paper clip and press the hole on the left side 30 IE SNC P8x52 03 e connect the power wait for 10sec and release the button 31 IE SNC P8x52 03 Technical specifications Information about technical specifications of the device Dimensions 40mm _ 73 mm 24 3 mm Basic parameters Supply voltage P8552 DC voltage from 4 9V to 6 1V coaxial connector 5x 2 1mm diameter positive pole in the middle m
22. in 250mA Supply voltage P8652 Power over Ethernet according to IEEE 802 3af PD Class 0 max 12 95W voltage from 36V to 57V DC For PoE are used pairs 1 2 3 6 or 4 5 7 8 or DC voltage from 4 9V to 6 1V coaxial connector 5x 2 1mm diameter positive pole in the middle min 250mA Consumption 1W depending on the operating mode Protection 32 IE SNC P8x52 03 Measuring interval IP30 case with electronic 2sec Accuracy depending on used probe e g probe DSTG8 C parameters Resolution 0 5 C in temperature range from 10 C to 85 C 2 0 C in temperature range from 10 C to 50 C 2 0 C in temperature range from 85 C to 100 C 0 1 C 0 1 RH Temperature measurement range limited by temperature range of used probe Recommended probes Number of channels Binray input type 55 C to 100 C Temperature probe DSTR162 C max length 10m Temperature probe DSTGL40 C max length 10m Temperature probe DSTG8 C max length 10m Humidity probe DSRH max length 5m Two cinch RCA connectors 4 measurement channels in device Three BIN inputs on WAGO 734 terminals Without galvanic isolation software configurable input dry contact ot voltage contact Binary inputs parameters dry contact Voltage on the unclosed contact 3 3V Current through closed contact 0 1mA Maximum resistivity of the contact lt 5kQ2 Binary inputs parameters voltage contact Communication port
23. ing 1 3 6 1 4 1 22626 1 5 2 ch 3 Actual value Int 10 1 3 6 1 4 1 22626 1 5 2 ch 4 Alarm on channel 0 1 2 Integer 1 3 6 1 4 1 22626 1 5 2 ch 5 High limit Int 10 1 3 6 1 4 1 22626 1 5 2 ch 6 Low limit Int 10 1 3 6 1 4 1 22626 1 5 2 ch 7 Hysteresis Int 10 1 3 6 1 4 1 22626 1 5 2 ch 8 Delay Integer 1 3 6 1 4 1 22626 1 5 2 ch 9 Unit String 1 3 6 1 4 1 22626 1 5 2 ch 10 Alarm on channel text String 1 3 6 1 4 1 22626 1 5 2 ch 11 Minimal value on channel String 1 3 6 1 4 1 22626 1 5 2 ch 12 Maximal value on channel String 1 3 6 1 4 1 22626 1 5 2 bin Binary input where bin 6 BIN1 bin 10 BIN5 1 3 6 1 4 1 22626 1 5 2 bin 1 Binary input name String 1 3 6 1 4 1 22626 1 5 2 bin 2 State of binary input text String 1 3 6 1 4 1 22626 1 5 2 bin 3 State of binary input Integer 1 3 6 1 4 1 22626 1 5 2 bin 4 Alarm on binary input text String 1 3 6 1 4 1 22626 1 5 2 bin 5 Alarm on binary input 0 1 Integer 1 3 6 1 4 1 22626 1 5 3 1 0 SNMP Trap text String 1 3 6 1 4 1 22626 1 5 4 1 1 ch nr History table value nr sample number Int 10 When alarm occurred a warning messages trap can be sent to selected IP addresses Addresses can be set using web interface Traps are sent via UDP protocol on port 162 The device can send following traps 23 IE SNC P8x52 03 Trap Description 0 0 Reset of the
24. ion allows to easy and instant access to data Data are accessible from multiple places by the Database Viewer software One license of Comet Database includes also one license for Database Viewer www cometsystem com
25. ion error Testing message Test Syslog message Email login error E mail sending error Email auth error Email some error Email socket error Email dns error SOAP file not found SOAP message sending error SOAP host error SOAP sock error SOAP delivery error SOAP dns error High alarm CHx Upper alarm on channel Low alarm CHx Lower alarm on channel Clearing CHx Clearing alarm on channel Error CHx Measuting error Alarm BINx Alarm on binary input Clearing BINx Clearing alarm on binary input SNTP The device allows time synchronization with NTP SNTP server SNMP protocol version 3 0 is supported RFC1305 Time synchronization is made every 24 hours Time synchronization every hour can be enabled For time synchronization it is necessary set IP address to the SNTP server It is also possible set GMT offset for correct time zone Time is used in graphs and history CSV files Maximum jitter between two time synchronization is 90sec at 24 hours interval 28 IE SNC P8x52 03 Troubleshooting The chapter describes the common problems with Web Sensor P8552 Web Sensor P8652 and methods how to fix these problems Please read this chapter before you will call technical support I forgot the device IP address IP address is factory set to 192 168 1 213 If you had changed it and forgot new IP address run the TSensor software and press Find device In the window are displayed all
26. l 1 Network ROM code 28 23 00 E7 00 00 00 3E Basic settings of the network interface Sensor temperature pro Alarm limits Enabled Channel 1 temperature C v Configuration of the alarm limits Channel 2 Channels ROM code 26 6E 90 53 01 00 00 FD General settings of the channels Sensor humidity temperature probe BIN Inputs Enabled Channel 2 humidity RH v Binary inputs settings t Apply settings Find sensors Clear channels Cancel changes MinMax memory Timestamps clear memory Maintenance Factory defaults info etc 13 IE SNC P8x52 03 Binary inputs Binary inputs can be enabled or disabled for states evaluation by the Enable option Name of the binary input is configurable max 14 characters Closed state description High voltage description allows to change name of binary input in the closed state Open state has name according Open state description Low voltage description field Alarm states are evaluated according set Time delay for alarm It can be selected that alarm 1s active at closed or open state of binary input Alarms on binary inputs can be disabled also Type of binary input is selectable option Input type Dry contact is a default option and allows to use input with door contacts and sensors with relay output Voltage contact option can be used with sensors like an AC detector SP008 Paimin Settings General General device settings Network Basic settings of the network int
27. o etc Configuration of the alarm emails Device can send warning email when alarm on measured channel occurs Email is also sent when alarm condition is cleared Email sending enabled SMTP server configuration For proper email sending it is necessary to setup connection to your SMTP server SMTP authentication can be used if needed For information about SMTP server settings please contact your network administrator or ISP SMTP server address SMTP server port SMTP authentication Username Password Email configuration smtp examplecom sensor example com Setup up to three address for email recipients Sender address is usually the same as the username of the SMTP authentication Email sender address Recipient 1 Recipient 2 Recipient 3 Short email Alarm email repeat sending interval Info email sending interval Alarm and Info emails attachment 16 sensor example com admin gmail com jara cimrman live com o lHor sd 1 Day Comma CSV files x Cancel changes IE SNC P8x52 03 Modbus a Syslog protocols ModbusTCP and Syslog protocol settings are configurable via menu Protocols Modbus server is enabled by default Deactivation is possible via Modbus server enabled option Modbus port can be changed via Modbus port field Syslog protocol can be enabled using item Syslog enabled Syslog messages are sent to IP address of the Syslog server field Syslog server IP addre
28. oftware 1s not included Website The device supports displaying of measured values history graphs and configuration using web browser History graphs are based on HTMLS canvas Web browser must support this feature for proper function of graphs Firefox Opera Chrome or Internet Explorer 9 can be used If the device has IP address 192 168 1 213 type into your browser http 192 168 1 213 Automatic refresh interval of the web pages can be changed from default value 10sec Actual measured values can be obtained using XML file values xml Values from history can be exported in CSV format Interval of storing values into internal history memory is configurable also History is erased after every reboot of the device Reboot of the device is performed when the power supply is disconnected and also after configuration change The device allows you to customize the design of web pages Details of how to change the design you can find in the manual appendix Manual appendix can be obtained from the manufacturer s website SMTP sending e mails When measured values are over the set limits the device allows send e mail to a maximum of 3 addresses E mail is send when alarm condition on the channel is cleared or a measuring error occurs It is possible to set repeat interval for email sending For correct sending of e mails it is necessary to set address of SMTP server Domain address can be used as SMTP server address too For proper function of D
29. ol settings Alarm events log System events log Clear events logs SNMP SNMPv1 protocol and SNMP Traps Restart Device will be restarted after dialog confirmation All history values are cleared after restart Restarting Time Synchronization with NTP server WWW and Security Web server and Security configuration MinMax memory Timestamps clear memory Maintenance Factory defaults info etc of the device will take a few seconds Restart device Factory defaults Factory defaults button restores device to factory settings Network parameters like a IP address subnet mask and gateway IP will not be changed Factory defaults Network parameters are changed while you close jumper inside the device After jumper closing it is necessary connect power supply Factory defaults have no effect to user correction inside probe 19 IE SNC P8x52 03 Parametet Value SMTP server address example com SMTP server port 25 Alarm email repeat sending interval off Info email repeat sending interval off Alarm and Info emails attachment off E mail recipients addresses cleared E mail sender sensot IP SMTP authentication off SMTP user SMTP password cleared E mail sending enabled off IP addresses SNMP traps recipients 0 0 0 0 System location cleared Password for SNMP reading public Sending SNMP T
30. on This procedure is only informative What is needed for operation To install the unit you need to the following equipment Before installation check if it s available e Web Sensor P8552 or Web Sensor P8652 power supply adapter 5V 250mA or switch with PoE support Before using the device is necessary to decide which way of powering will be used PoE is supported by Web Sensor P8652 RJ45 LAN connection with appropriate cable free IP address in your network up to 2 temperatures probes type DSTR162 C DSTGL40 C DSTG8 C or relative humidity probe DSRH up to 3 sensors with two state output to connection into binaty inputs of Web Sensor dry contacts or voltage contacts Mounting the device check if the equipment from previous chapter is available install the latest version of TSensor software This software will help you find device on network and to change IP address of the device Device configuration is made using web interface TSensor software can be free downloaded from the manufacturer s website Due to reducing impact to environment is CD not part of shipment Software on CD can be supplied optionally contact your network administrator to obtain following information for the connection to the network IE SNC P8x52 03 IP address Gateway DNS server IP Netmask check if there is no IP address conflict when you connect the device into netwotk for the first time The device has from fa
31. r must be used if the device is not powered by Ethernet cable Device case holder for RACK 19 MP046 MP046 is a universal holder for mounting of Web Sensor P8552 and Web Sensor P8652 to RACK 19 Probes holder for RACK 19 MP047 Universal holder for easy mounting probes in RACK 19 Magnetic door contact SA200A with cable shielding f hite genie Dry contact SPOO08 power detector SP0008 is AC voltage presence sensor with optical LED indicator Input voltage 230 Vac 50 Hz power plug type C response time approx 1 sec Voltage contact LD 12 flood detector Water flood detector is designed for a detection of water leakages Dry contact Notice Before detector installation please read enclosed user guide carefully 37 IE SNC P8x52 03 SD 280 optical smoke detector This device is designed to detect the presence of fire inside residential or commercial buildings 12V TMP ALARM Dry contact T Notice Before detector installation please read enclosed user guide carefully JS 20 PIR motion detector This P I R motion detector is used to protect interiors Dry contact Notice Before detector installation please read enclosed user guide carefully Comet database Comet database provide a complex solution for data acquisition alarm monitoring and measured data analyzing from Comet devices Central database server is based on MS SQL technology Client server concept
32. rameters are configurable only by the TSensor software Parameter MTU size can reduce size of the Ethernet frame Lowering of this size can solve some communication problems mainly with Cisco network infrastructure Sensor software can set offset of values at temperature probes At DSRH humidity probe is possible set correction of the humidity and temperature Factory defaults Factory defaults button set the device into factory configuration Network parameters IP address Subnet mask Gateway DNS are left without changes esmine Settings Maintenance Info General i Basic informations about device Find more detailed information on the diagnostic page Please send the General device settings diagnostic file together with request to support Network Device type P8652 Basic settings of the network interface Serial number 07940143 Alarm limits Configuration of the alarm limits MAC address 00 80 A3 93 4E 3F Channels Firmware version 4 5 6 0 3307 1 50 General settings of the channels Build firmware notice BETA 1 BIN Inputs Binary inputs settings Device uptime 2 h 21 min 29 sec SOAP protocol Setup SOAP protocol for database system Diagnostic file 192 168 1 47 diag lo Email Evnets Logs Alarm emails configuration Events logs with the system or alarm messages can be downloaded in CSV file format for further analysis After request confirmation both logs are cleared together Protocols Syslog and ModbusTCP protoc
33. rap off Website refresh interval sec 10 Website enabled yes Website port 80 Security off Administrator password cleared User password cleared Modbus TCP protocol port 502 Modbus TCP enabled Yes History storage interval sec 60 SOAP message when alarm occurs yes SOAP server port 80 SOAP server address cleared SOAP sending interval sec 60 SOAP protocol enabled off Syslog server IP address 0 0 0 0 Syslog protocol enabled off SNTP server IP address 0 0 0 0 GMT offset min 0 NTP synchronization every hour off SNTP synchronization enabled off MTU 1400 Periodic restart interval off Demo mode off Turn on all channels yes Upper limit 50 Lower limit 0 Hysteresis hysteresis for alarm clearing 1 Delay time delay of alarm activation sec 30 Channel enabled all channels Unit on the channel C or RH according used probe Channel name Channel X where X is 1 to 5 Enabled binary channels all channels Binary channel name BIN input X where X is 1 to 3 Binary input alarm on closed 20 IE SNC P8x52 03 Input type dry contact Time delay for binary input sec 2 Closed state description on Open state description off Device name Web Sensor 21 IE SNC P8x52 03 Communication protocols Short introduction to communication protocols of the device To use some communication protocols is necessary software which can use the protocol This S
34. setup of server port can be used option SOAP server port Device sends SOAP message according selected Sending interval Option Send SOAP message when alarm occurs sends message when an alarm on channel occurs or alarm is cleared These SOAP messages are sent asynchronously to selected interval Beminnen Settings SOAP Setup SOAP protocol for database system Current measured values are sent as XML files For more General information please read the user guide for database system General device settings SOAP protocol enabled Network 3 Basic settings of the network interface SOAP server address http 192 168 1 132 soap Alarm limits SOAP server port 80 Configuration of the alarm limits Sending interval 20 Sec iv Channels General settings of the channels Send SOAP message when alarm occurs v BIN Inputs Binary inputs settings Apply settings Cancel changes SOAP protocol Setup SOAP protocol for database system Email Alarm emails configuration MinMax memory Timestamps clear memory Maintenance Factory defaults info etc Email Email sending enabled option allows email features It is necessary set address of the SMTP server into SMTP server address field Domain name for SMTP server can be used Default port of the SMTP server can be changed using item SMTP server port SMTP authentication can be enabled using SMTP authentication option When authentication is enabled Username and Password must be set For s
35. ss Pittman Settings Protocols ModbusTCP protocol General Configuration of the ModbusTCP protocol Current measured values can be read using ModbusTCP General device settings protocol Modbus registers are described inside the user manual Network Modbus server enabled Basic settings of the network interface P Modbus port 502 t t Syslog protocol y Configuration of the Syslog protocol Alarm messages can be sent to the Syslog server using UDP protocol Syslog enabled Email Alarm emails configuration Syslog server IP address 192 168 1 132 Protocols Syslog and ModbusTCP protocol settings Apply settings Cancel changes SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server SNMP For reading values via SNMP it is necessaty to know passwotd SNMP read community SNMP Trap can be delivered up to three IP address IP address of the Trap recipient SNMP Traps are sent at alarm or error state on the channel Trap feature can be enabled by option Trap enabled Sasmi Settings SNMP Configuration of the SNMPv1 protocol and SNMP Traps Current measured values can be read using SNMP General protocol When alarm on channel occurs a warning message Trap can be sent to selected IP addresses General device settings SNMP read community public Network Basic settings of the network interface System location Area 51 a Trap enabled v c IP address of the Trap recipient 1 192 16
36. sssiasedessisseissecessiessdezeiuseiasedessivnesovedaseiassieseiteadeseiesviasednantbanseris 35 Preventive taittelance oue utuntur tibus ee un s Lr a ERU NAN 35 Optional AccESSOTes M 36 IE SNC P8x52 03 Introduction This chapter provides basic information about device Before starting please read this manual carefully Web Sensor P8552 and Web Sensor P8652 are used to measure temperature or relative humidity up to two external probes This allows to measure values from two different places by one device Temperature can be displayed in C or F Relative humidity have unit RH Device is equipped by three binary inputs Binary inputs allow get values from dry contacts or binary sensors with voltage output Type of the binary input is selectable in device setup Communication with the device is realized via Ethernet network Device P8652 can be powered from external power supply adapter or by using power over Ethernet PoE Web Sensor P8552 supports powering from adapter only General safety rules The following summary is used to reduce the risk of injury or damage the device To prevent injury please follow instructions in this manual serviceable parts inside i The device can be services only by a qualified person The device contains no Don t use the device if it doesn t work correctly If you think that the device is not wotking correctly let check it by qualified service person Don t disassem
37. tocol e SNMPv1 protocol e SOAP protocol The device can also be used to check measured values and if the limit is exceeded device sends warning messages Possible ways to sending warning messages e Sending e mails up to 3 e mail addresses e Sending SNMP traps up to 3 configurable IP addresses e Displaying the alarm status on web page e Sending messages to Syslog server The device setup can be made by the TSensor software or by web interface TSensor software can be free downloaded from the manufacturer s website Also you will find latest firmware for your device at webpages Do not upload to your device firmware which is not designed for it Unsupported firmware can damage your device If you want to use PoE you must use PoE switch compatible with IEEE 802 3af standard Reliability of warning messages delivering e mail trap syslog depends on actual availability of necessary network services The device should not be used for critical applications where malfunction could cause to injury or loss of human life For highly reliable systems redundancy is essential For more information please see standard IEC 61508 Never connect the device directly to the Internet If it is necessary connect the device to the Internet properly configured firewall must be used Firewall can be partially replaced with the NAT IE SNC P8x52 03 Getting started Here you can find information necessary to put newly purchased equipment to operati
38. uccessfully email sending it is necessary insert Email sender address This address is usually same as username of the SMTP authentication Into fields Recipient 1 to Recipient 3 it is possible set address of email recipients Option Short email enable sending emails in short format This format is usable when you need to forward emails into SMS messages When option Alarm email repeat sending interval is enabled and there is active alarm on channel then emails with actual values are sent repeatedly Info email sending interval option enables sending emails at selected time interval CSV history file can be sent together with the repeat info emails This feature can be enabled by Alarm and Info emails attachment option It is possible to test email function using button Apply and test This button save a new settings and send a testing email immediately 15 IE SNC P8x52 03 General General device settings Network Basic settings of the network interface Alarm limits Configuration of the alarm limits Channels General settings of the channels BIN Inputs Binary inputs settings SOAP protocol Setup SOAP protocol for database system Email Alarm emails configuration Protocols Syslog and ModbusTCP protocol settings SNMP SNMPv1 protocol and SNMP Traps Time Synchronization with NTP server WWW and Security Web server and Security configuration MinMax memory Timestamps clear memory Maintenance Factory defaults inf
39. value does not drop below the set limit and therefore was in Point 4 caused alarm At this moment were sent e mails traps and set alarm flag on website SNMP and Modbus The alarm lasted up to Point 5 when the temperature dropped below the set hysteresis temperature limit hysteresis At this moment was active alarm cleared and e mail send When alarm occurs alarm messages will be sent In case of power failure or device reset e g changing the configuration will new alarm state evaluated and new alarm messages will be send 12 IE SNC P8x52 03 Channels Channel can be enabled or disabled for measuring using item Enabled Channel can be renamed max 14 characters and it is possible select unit of measured value according connected probe type When channel is not used it is possible copy to it one of other channels option Clone channel This option is not available at fully occupied device Find sensors button starts searching for connected probes All changes must be confirmed using Apply settings button History values are cleared after changing of channel settings Pitman Settings Channels General settings of the channels Find sensors button starts search for connected probes Connected General probes can be cloned to unused channels To change order of ROM codes Drag and Drop feature can be General device settings used History values of the channel will be cleared immediately after changing channel settings Channe
40. x52 03 Address DEC Address HEX Value 39970 0x9C22 1st two digits from serial number BCD 39971 0x9C23 2nd two digits from serial number BCD 39972 0x9C24 3rd two digits from serial number BCD 39973 0x9C25 4th two digits from serial number BCD 39974 0x9C26 Device type ulnt 39975 39979 0x9C27 OxX9C2B Actual measured value on channel Int 10 39980 39984 0x9C2C 0x9C30 Unit on the channel Ascii 39985 39989 0x9C31 0x9C35 Channel alarm state ulnt 39990 39994 0x9C36 0x9C3A Binaty input state ulnt 39995 39999 0x9C3B Ox9C3F Binary input alarm state ulnt 40000 0x9C40 Channel 1 temperature or humidity Int 10 40001 0x9C41 Channel 1 alarm status Ascii 40002 0x9C42 Channel 1 upper limit Int 10 40003 0x9C43 Channel 1 lower limit Int 10 40004 0x9C44 Channel 1 hysteresis Int 10 40005 0x9C45 Channel 1 delay ulnt 40006 0x9C46 Channel 2 temperature or humidity Int 10 40007 0x9C47 Channel 2 alarm status Ascii 40008 0x9C48 Channel 2 upper limit Int 10 40009 0x9C49 Channel 2 lower limit Int 10 40010 Ox9C4A Channel 2 hysteresis Int 10 40011 Ox9C4B Channel 2 delay ulnt 40012 0x9C4C Channel 3 temperature or humidity Int 10 40013 0x9CAD Channel 3 alarm status Ascii 40014 Ox9CAE Channel 3 upper limit Int 10 40015 Ox9CAF Channel 3 lowet limit Int 10 40016 0x9C50 Channel 3 hysteresis Int 10 400