Home

MELINDA IDRO THERMO PRODUCTS USER MANUAL

image

Contents

1. GENERAL MENU BASIC INSTRUCTIONS n OEO ENABLE 5 esteri EDASTAMA A TYPE AND REPLACEMENT OF BATTERIES COMMISSIONING SETTINGS MAINS FREQUENCY 50 60HZ ADJUSTING TIME DAY MONTELAND YEAR 13 ADJUSTING LANGUAGE u san 13 OTHER FUNCTIONS AIR DISCHARGE FIRST LOAD ann ee OPERATION AND LOGIC ADDITIONAL THERMOSTAT ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY 15 ADDITIONAL THERMOSTAT INSTALLATION SET POWER SET CLOCK ADJUSTING LANGUAGE ccseccescsssvvausssssszensazessecoastesssseceasscsossuncasastoszetesscoteudeleasstansstsus BE A E E EEES EEE MEPEREREE MERE E EPA ECER STAND BY ROUTI
2. provincial and town council Standards present in the country in which the appliance has been installed as well as the instructions contained in this manual The Manufacturer cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased All electric components that make up the product must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning SAFETY THE GENERATOR MUST NOT BE USED BY PERSONS INCLUDING CHILDREN WITH REDUCED PHYSICAL SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN MUST BE CHECKED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE DO NOT TOUCH THE GENERATOR WHEN YOU ARE BAREFOOT OR WHEN PARTS OF THE BODY ARE WET OR DAMP THE SAFETY AND ADJUSTMENT DEVICES MUST NOT BE MODIFIED WITHOUT THE AUTHORISATION OR INDICATIONS OF THE MANUFACTURER DO NOT PULL DISCONNECT TWIST ELECTRIC CABLES LEAVING THE STOVE EVEN IF DISCONNECTED FROM THE ELECTRIC POWER SUPPLY MAINS IT IS ADVISED TO POSITION THE POWER SUPPLY CABLE SO THAT IT DOES NOT COME INTO CONTACT WITH HOT PARTS OF THE APPLIANCE THEPOWER SUPPLY PLUG MUST BE ACCESSIBLE AFTER INSTALLATION DO NOT CLOSE OR
3. 4 time spans within a day to use every day of the week The switch on and switch off time can be set in every time slot along with the days of use of the programmed time slot and the desired water temperature 65 80 C The setting of the current day and time is essential to ensure the chrono operates correctly RECOMMENDATIONS Before using the chrono function set the current day and time Therefore check that the points listed in the Set clock sub chapter have been followed so that the chrono function works Aside from programming it activate it as well The ignition and switch off times must be within the arc of one day from 0 to 24 and not over several days Example CORRECT INCORRECT Switch on time 07 00 Switch on time 22 00 Switch off time 18 00 Switch off time 05 00 ENGLISH 17 OExtraflame CONTROLS PROCEDURE e 9 Press key 6 Proceed by pressing key 2 until SET CHRONO is displayed Confirm using key 6 Use keys 4 5 to enable disable set edit the time Press key 2 to go forwards 3 to go back Press key 1 several times to confirm and exit the menu DISPLAY TEMPERATURE MEANING SET CHRONO ENABLE CHRONO On off Enable disable the whole set chrono ENABLE PRG1 On off Enable disable PRG1 ENABLE PRG2 On off Enable disable PRG2 ENABLE PRG3 On off Enable disable PRG3 ENABLE PRG4 On off Enable disable PRG4
4. REDUCE THE DIMENSIONS OF THE AIRING VENTS IN THE PLACE OF INSTALLATION THE AIRING VENTS ARE ESSENTIAL FOR CORRECT COMBUSTION DO NOT LEAVE THE PACKAGING ELEMENTS WITHIN REACH OF CHILDREN OR UNASSISTED DISABLED PERSONS THEHEARTH DOOR MUST ALWAYS BE CLOSED DURING NORMAL FUNCTIONING OF THE PRODUCT WHEN THE APPLIANCE IS FUNCTIONING AND HOT TO THE TOUCH ESPECIALLY ALL EXTERNAL SURFACES ATTENTION MUST BE PAID CHECK FOR THE PRESENCE OF ANY OBSTRUCTIONS BEFORE SWITCHING THE APPLIANCE ON FOLLOWING A PROLONGED PERIOD OF INACTIVITY THE GENERATOR HAS BEEN DESIGNED TO FUNCTION IN ANY CLIMATIC CONDITION IN PARTICULARLY ADVERSE CONDITIONS STRONG WIND FREEZING SAFETY SYSTEMS MAY INTERVENE THAT SWITCH THE GENERATOR OFF IF THIS OCCURS CONTACT THE TECHNICAL AFTER SALES SERVICE AND ALWAYS DISABLE THE SAFETY SYSTEMS N THE EVENT THE FLUE CATCHES FIRE USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE THIS APPLIANCE MUST NOT BE USED TO BURN WASTE DONOT USE ANY FLAMMABLE LIQUIDS FOR IGNITION DURING THE FILLING PHASE DO NOT PUT THE BAG OF PELLETS TO INTO CONTACT WITH THE PRODUCT THE MAJOLICAS ARE TOP QUALITY ARTISAN PRODUCTS AND AS SUCH CAN HAVE MICRO DOTS CRACKLES AND CHROMATIC IMPERFECTIONS THESE FEATURES HIGHLIGHT THEIR VALUABLE NATURE DUE TO THEIR DIFFERENT DILATION COEFFICIENT THEY PRODUCE CRACKLING WHICH DEMONSTRATE THEIR EFFECTIVE AUTHENTICITY TO CLEAN THE MAJOLICAS IT IS RECOMMENDED TO
5. START PRG1 OFF 00 00 23 50 PRG1 ignition time STOP PRG1 OFF 00 00 23 50 PRG1 switch off time MONDAY SUNDAY On off Enable disable the days of PRG1 SET PRG1 65 80 C PRG1 boiler temperature START PRG2 OFF 00 00 23 50 PRG2 ignition time STOP PRG2 OFF 00 00 23 50 PRG2 switch off time MONDAY SUNDAY On off Enable disable the days of PRG2 SET PRG2 65 80 C PRG2 boiler temperature START PRG3 OFF 00 00 23 50 PRG3 ignition time STOP PRG3 OFF 00 00 23 50 PR3 switch off time MONDAY SUNDAY On off Enable disable the days of PRG3 SET PRG3 65 80 C PRG3 boiler temperature START PRG4 OFF 00 00 23 50 PRG4 ignition time STOP PRG4 OFF 00 00 23 50 PRG4 switch off time MONDAY SUNDAY On off Enable disable the days of PRG4 SET PRG4 65 80 C PRG4 boiler temperature WHEN THE WEEKLY PROGRAMMER IS ACTIVE A BOX OF THE RELATIVE ICON WILL APPEAR ON THE CONTROL BOARD STATUS References reserved to the technician SETTINGS SET CLOCK ADJUSTING LANGUAGE seechapter commissioning settings DISPLAY The DISPLAY menu contains two sub menus Key lock Brightness 18 ENGLISH OExtraflame KEY LOCK The menu allows the user to lock the display keys like with mobile phones CONTROLS PROCEDURE Press key 6 Proceed by pressing key 2 until SETTINGS IS DISPLAYED Confirm using key 6 Press key 2 until DISPLAY is shown Confirm using key 6 KEY LOCK will appear confirm with key 6 Use keys 4 5 to enable ON disable OFF
6. be performed with the utmost care after reading the instructions procedures and times reported in this user and maintenance manual CLEANING THE SURFACES AND COVERING Never use abrasive or CHEMICALLY AGGRESSIVE detergents to clean Surfaces must be cleaned when the generator and covering are completely cold To carry out maintenance on surfaces and metal parts just use a cloth dampened with water or water and neutral soap Failure to comply with the directions can damage the generator s surfaces and void the warranty CLEANING THE CERAMIC GLASS Never use abrasive or CHEMICALLY AGGRESSIVE detergents to clean The ceramic glass must be cleaned only when the glass is completely cold To clean the ceramic glass use a dry brush and A NEWSPAPER THAT HAS BEEN DAMPENED AND PASSED THROUGH SOME ASH If the glass is very dirty only use a detergent specifically designed for ceramic glass Spray a modest amount on a cloth and use it on the ceramic glass Do not spray the detergent or any other liquid directly onto the glass or gaskets Failure to comply with the directions can damage the surfaces of the ceramic glass and void the warranty CLEANING THE PELLET TANK When the tank is completely empty unplug the generator s power supply cable and first remove residues dust shavings etc from the empty tank before emptying it DAILY Burn pot Remove the burn pot from the relevant compartment and free the holes using the special poker supplie
7. confirm with key 6 Cut the power to interrupt FIRST LOAD This function allows the user to activate the pellet feeding motor reducer for continuous functioning To activate the function When the stove is cold and OFF press keys 2 and 5 at the same time for a couple of seconds the scrolling message first load will appear on the display To interrupt continuous loading simply press key 1 ENGLISH 13 OExtraflame OPERATION AND LOGIC IGNITION Once the points listed previously have been checked press key 1 for three seconds to ignite the stove 15 minutes are available for the ignition phase After ignition and having reached the control temperature the stove interrupts the ignition phase and passes to STARTING STARTING During the start up stage the stove stabilises combustion increasing it gradually to then start ventilation and switch to the WORK mode WORK During the work phase the stove reaches the set power see following item SET POWER ADJUSTMENT Set the functioning power from 1 to 5 settable using keys 2 3 Power 1 minimum level Power 5 maximum level SET H20 TEMPERATURE ADJUSTMENT Set the boiler temperature from 65 80 C settable using keys 4 5 PUMP OPERATION The pump activates water circulation when the temperature of the water inside the stove reaches approx 60 C As the pump always functions above 60 an always open heating area is recommended to make product functioning homogene
8. gas appliances intended for room heating with or without production of domestic hot water and in adjacent and adjoining premises or inwhich in any case the depression measured during installation between the internal and external environment is greater than 4 Pa INSTALLATIONS IN BATHROOMS BEDROOMS AND STUDIO FLATS Installation in bathrooms bedrooms and studio flats is only allowed for sealed or closed hearth appliances with ducted combustion air taken from the outside POSITIONING AND SAFETY DISTANCES The support surfaces and or points must have a suitable capacity to bear the overall weight of the appliance accessories and coverings If the floor is made of a combustible material we recommending using a non combustible material to protect the front part from any burnt material which might fall during routine cleaning operations The generator must be level to function properly A M lt The adjacent side and rear walls and the supporting surface must be made of non SSS combustible material Installation adjacent to combustible or heat sensitive materials is B Pad allowed as long as there is a suitable safety distance in between which for pellet stoves is EE KE REFERENCES INFLAMMABLE OBJECTS NON INFLAMMABLE OBJECTS Air inlet A 200 mm 100 mm TENE KN B 1500 mm 750 mm C 200 mm 100 mm floor protection INSTALLING INSERTS When installing inserts access must be prevented to th
9. once a year As the generator uses pellets as solid fuel it needs an annual routine maintenance interval that needs to be performed by an authorised technician by only using original spare parts Failure to do so can affect the appliance s safety and you may no longer be entitled to the warranty conditions By following the cleaning schedule reserved to the user and reported in the user and maintenance manual one ensures correct combustion in the generator over time thereby preventing any anomalies and or malfunctions that may require more work to be performed by the technician Requests for routine maintenance are not covered by the product s warranty DOOR ASH DRAWER AND BURN POT GASKETS The gaskets ensure the tightness of the stove and its consequent proper operation They must be checked periodically in the event they are worn or damaged they must be replaced immediately These operations must be carried out by a qualified technician CONNECTION TO THE FLUE Vacuum and clean the pipe that leads to the flue yearly or whenever necessary If there are horizontal sections any residue must be removed before it obstructs the flue PUTTING THE EQUIPMENT OUT OF SERVICE END OF THE SEASON At the end of every season before turning off the stove we recommend completely emptying the pellet tank and using a vacuum cleaner to clear up any pellets and dust residue inside it You should also disconnect the generator from the mains and to ensure
10. sensor in the primary air channel and the combustion chamber Contact after sales centre 25 OExtraflame 26 ENGLISH QExtraflame ENGLISH 27 uExtraflame Riscaldamento a Pellet Extraflame S p A Via Dell Artigianato 12 36030 MONTECCHIO PRECALCINO VI ITALY 20 39 0445 865911 39 0445 865912 DZ info extraflame it www lanordica extraflame com The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice in order to improve its products This manual cannot be considered as a contract for third parties 27 02 2015 004276483 MU MELINDA IDRO LCD 001R
11. using key 6 Use keys 4 or 5 to setthe ROOM AIR TEMP SET Confirm using key 6 Use keys 4 or 5 to setthe H20 TEMP SET Press key 1 several times to confirm and exit the menu 6 6 USER MENU ENABLE FAN This menu allows for the models envisioned to enable or disable the operation of the tangential fan CONTROLS PROCEDURE Press key 6 T Proceed by pressing key 2 until USER MENU is displayed Confirm using key 6 7287 Use keys 4 5 to enable disable ventilation Press key 1 several times to confirm and exit the menu 4 V1 AIR The menu allows the user to adjust the speed of the front fan in percentage for envisioned models CONTROLS PROCEDURE Press key 6 Proceed by pressing key 2 until USER MENU is displayed Confirm using key 6 Press key 2 until V1 AIR appears Use keys 4 5 to increase 4 or decrease 5 Press key 1 several times to confirm and exit the menu 6 16 ENGLISH OExtraflame RESET Allows the user to reset all values modifiable by the user to the default values CONTROLS PROCEDURE Press key 6 Proceed by pressing key 2 until USER MENU is displayed Confirm using key 6 Press key 2 until RESET is displayed Press keys 4 5 to select ON and press key 6 DONE will appear on the display to confirm 0 6 0 LOW The following menu allows the user to adjust the percentage of pellet feed If the stove has functioning prob
12. NE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS 22 PUTTING THE EQUIPMENT OUT OF SERVICE END OF THE SEASON DISPLAYS scsssssssssssssssssescsssscscsssscsssccssscsssccssccssssssscssocssecssscsssscssonssoeses ALARM ENGLISH 3 OExtraflame We thank you for having chosen our company our product is a great heating solution developed from the most advanced technology with top quality machining and modern design aimed at making you enjoy the fantastic sensation that the heat of a flame gives in complete safety WARNINGS This instructions manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to another owner or user or if transferred to another place If it is damaged or lost request another copy from the area technician This product is intended for the use for which it has been expressly designed The manufacturer is exempt from any liability contractual and extracontractual for injury damage caused to persons animals and objects due to installation adjustment and maintenance errors and improper use Installation must be performed by qualified staff which assumes complete responsibility for the definitive installation and consequent good functioning of the product installed One must also bear in mind all laws and national regional
13. Press key 1 several times to confirm and exit the menu 99999 USING THE KEY LOCK AFTER ACTIVATION ie TO LOCK THE KEYBOARD PRESS KEYS 1 AND 5 AT THE SAME TIME UNTIL THE FOLLOWING APPEARS KEYS LOCKED TO UNLOCK THE KEYBOARD PRESS KEYS 1 AND 5 AT THE SAME TIME UNTIL THE FOLLOWING APPEARS KEYS UNLOCKED BRIGHTNESS This menu allows the user to adjust the brightness of the display The possible settings range from OFF 10 to 31 Activating OFF the back light of the display will go off after a preset delay The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine CONTROLS PROCEDURE EE Press key 6 Proceed by pressing key 2 until SETTINGS IS DISPLAYED Confirm using key 6 Press key 2 until DISPLAY is shown and use key 6 to confirm Press key 2 until BRIGHTNESS appears and confirm with key 6 Use keys 4 5 to set the brightness GE Press key 1 several times to confirm and exit the menu STAND BY 99 6 9 The Stby function is used if immediate stove switch off or modulation via an additional thermostat is desired CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several times until SETTINGS is displayed Press key 6 Press key 2 until STAND BY is displayed and use key 6 to confirm 0 O Use keys 4 5 to select enable ON disable OFF Press key 1 several times to confirm and exit the menu 9 AUX If using pow
14. USE A SOFT DRY CLOTH IF A DETERGENT OR LIQUID IS USED THE LATTER COULD PENETRATE INSIDE THE CRACKLES HIGHLIGHTING THEM ROUTINE MAINTENANCE Based on Decree 22 January 2008 n 37 art 2 routine maintenance means interventions aimed at reducing degradation due to normal use as well as dealing with accidental events entailing the need of first interventions which however do not modify the structure of the system upon which one is intervening or its intended use according to the requirements laid down by the technical standards in force and by the manufacturer s use and maintenance manual 4 ENGLISH OExtraflame HYDRAULIC SYSTEM Certain concepts referring to the Italian Standard UNI 10412 2 2009 are described in this chapter As previously described when installing all national regional provincial and council Standards in force provided by the country in which the appliance has been installed must be complied with During installation of the generator it is MANDATORY to adjust the system with a manometer in order to display the water pressure TABLE OF THE DEVICES FOR CLOSED VESSEL SYSTEMS PRESENT AND NOT PRESENT IN THE PRODUCT Safety valve Pump control thermostat it is controlled by the water probe and the board program Acoustic alarm activation thermostat Water temperature indicator display SIS Pressure transducer with view on the display Acoustic alarm Automatic adjustme
15. condensation and prolongs the generator s life span The manufacturer recommends using the 55 C model with 1 hydraulic connections Valve sold as an accessory optional ENGLISH 5 OExtraflame INSTANT DOMESTIC HOT WATER PRODUCTION KIT Warnings if the instant hot water production kit is to be used contact the company technical after sales service STOVE POSITIONING For correct product functioning it is recommended to position it in a way that it is perfectly level with the aid of a spirit level REARMING The figures below show the positions for rearming the tank 85 C and 20 100 C We recommend contacting a qualified technician in the event rearming occurs to verify its cause THERMO PRODUCTS FEATURES o lt a z zi Water content of the thermo product heat exchanger 1 13 Volume of expansion vessel integrated into thermo product I 6 Maximum content of water in the system for integrated expansion vessel I 23 3 bar safety valve integrated into the thermo product YES Minimum and maximum pressure switch integrated into the thermo product YES Pump integrated into the thermo product YES Pump max head m 6 7 6 Content of water in the system in addition to that of the thermo product that can be managed with the integrated expansion 5 vessel An additional expansion vessel must be installed for a higher content of water 3 3 r 2 T
16. ction is in progress only if the generator has been in an OFF state for at least 96 hours the pump is ANTILOCK activated for the time pre set by the manufacturer in order to prevent it from blocking AUTO BLOW The automatic blow is active EXCHANGER BLOCK Automatic exchanger cleaning is blocked DISPLAY EXPLANATION SOLUTION On indicates the presence of an alarm indicates the presence of analarm Flashing indicates the deactivation of the depression sensor p The alarm can be reset pressing key 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have elapsed from when the alarm was displayed ASPIRATION Fumes motor fault Contact after sales centre FAULT on applicable models 24 ENGLISH OExtraflame FUMES PROBE Fumes probe failure Contact after sales centre HOT FUMES High flue gas temperature Check pellet feed see Pellet feed adjustment If the problem cannot be solved contact an authorised technician The door is not closed correctly Check hermetic door closure The ash drawer is not closed correctly Check hermetic closure of the ash drawer ALGAN GRS The combustion chamber is dirty Check cleanliness of the fumes pipe of the sensor in the primary air channel The flue exhaust pipe is blocked and the combustion chamber The pellet feed box is empty Check for the presence of pellets in the feed box NO FORMEN Adjust pellet flow see P
17. d remove the ash from the burn pot using a vacuum cleaner Vacuum the ash deposited in the brazier compartment 20 ENGLISH OExtraflame DAILY Scrapers Cleaning the heat exchangers allows the user to guarantee constant heat output over time This type of maintenance must be performed at least once a day To do this just use the relevant scrapers positioned in the upper part of the stove making upward movements and vice versa several times WEEKLY Clean the combustion chamber and the ash drawer Empty the ash drawer every week or when required It is recommended to remove the ash in the combustion chamber at least once a week using a suitable vacuum cleaner n c MONTHLY For the model in the picture below it is recommended to remove the deflector to facilitate cleaning the chamber and the ash drawer ENGLISH 21 OExtraflame MONTHLY MELINDA IDRO Remove the ash accumulated at the top of the hearth wall see figure below ROUTINE MAINTENANCE CARRIED OUT BY AUTHORISED TECHNICIANS Routine maintenance must be performed at least
18. e building it must always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be provided for cleaning 99 9 CHIMNEY The chimney caps must meet the following requirements they must have a useful outlet section no less than double that of the chimney ducted system on which it is installed they must be adapted in order to prevent the penetration of rain and snow in the chimney ducted system they must be built so that in the event of winds coming from all directions and from any angle the expulsion of combustion products is in any case ensured EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY Protection from rain and wind Protection from rain and wind TS J Insulated flue Max 3 mt T fitting Insulated T fitting with inspection Condensation proof with is T fitting with inspection inspection plug plug OA OO DE CONNECTION TO THE MAINS ELECTRIC SUPPLY The generator is supplied with an electric power cable to be plugged into a 230V 50 Hz socket possibly with a circuit break
19. e conditions and the preset timer have been satisfied DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION C DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE FILLING PHASE IN THE EVENT OF CONTINUOUS NO IGNITION CONTACT AN AUTHORISED TECHNICIAN NO IGNITION FIRST IGNITION COULD EVEN FAIL AS THE AUGER IS EMPTY AND IS NOT ALWAYS ABLE TO LOAD THE BURN POT WITH THE REQUIRED AMOUNT OF PELLETS ON TIME TO REGULARLY START THE FLAME IF THE PROBLEM OCCURS AFTER ONLY A FEW MONTHS WORKING CHECK THAT ROUTINE CLEANING STATED IN THE STOVE BOOKLET HAS BEEN CARRIED OUT CORRECTLY BURN POT UPPER DIVIDER IT IS FORBIDDEN TO USE THE APPLIANCE WITHOUT THE DIVIDER AND OR GLASS PROTECTION SEE THE FIGURE TO THE SIDE ITS REMOVAL JEOPARDISES THE SAFETY OF THE PRODUCT AND IMMEDIATELY VOIDS THE WARRANTY PERIOD IN THE CASE OF WEAR OR DETERIORATION REQUEST AFTER SALES ASSISTANCE FOR REPLACEMENT OF THE PART REPLACEMENT THAT IS NOT UNDER GUARANTEE AS THE COMPONENT IS SUBJECT TO WEAR GLASS PROTECTION 14 ENGLISH OExtraflame ADDITIONAL THERMOSTAT N B Installation must be performed by an authorised technician There is a possibility to thermostat a room adjacent to the room where the stove is positioned just connect a thermostat following the procedure described in the next step it is recommended to position the optional mechanical thermostat at a height of 1 50 m from the floor Stove functioni
20. e internal parts of the appliance and it must not be possible to access live parts during extraction operations Any wiring for example the power cable or room probe must be positioned so as not to be damaged during movement of the insert and must not come into contact with hot parts VENTILATION AND AERATION OF THE INSTALLATION PREMISES Ventilation is deemed sufficient when the room is equipped with air inlets according to the table posse Mr Minimum net opening value of Appliance categories Reference standard net opening section with respect to A the ventilation duct the appliance fumes outlet section Pellet stoves UNI EN 14785 80 cm Boilers UNI EN 303 5 50 100 cm In any case ventilation is deemed sufficient when the pressure difference between the external and internal environment is equal to or less than 4 Pa ENGLISH 7 OExtraflame In the presence of type B gas appliances with intermittent operation not intended for heating they must have their own aeration and or ventilation opening The air inlets must meet the following requirements they must be protected with grids metal mesh etc but without reducing the net useful section they must be made so as to make the maintenance operations possible positioned so that they cannot be obstructed The clean and non contaminated air flow can also be obtained from a room adjacent to that of installation indirect aeration and ventilation as l
21. ellet feed adjustment Pellet feed calibration inadequate MN IGNITION Th rmostat bulbs Check the procedures described in the Ignition chapter PP Check the bulb thermostats see Rearms chapter NO IGNITION No current anion hase Set the stove on OFF using key 1 and repeat the procedure described in the BLACK OUT 9 9 Ignition chapter Thie pellet teed boxis empty Check for the presence of pellets in the feed box NO PELLETS No pellet feed Adjust the pellet flow see Pellet feed adjustment The motor reducer does not feed pellets J P J ee Mia ib di Check hermetic door closure DEPRESSION ALARM y Check hermetic closure of the ash drawer The combustion erim Check cleanliness of the fumes pipe and the combustion chamber The flue exhaust pipe is blocked dirty PIP 1 DEBIMETER Flow sensor faulty FAULT Contact after sales centre Possible air in the system vent the system Lack of adequate circulation Keinen Lack of or inadequate safety zone H20 OVERTEMP The water the stove has exceeded 95 C Unsuitable circulation Possible circulator anomaly If the problem persists the reset operations must be carried out by an authorised technician The automatic burn pot cleaning is blocked Dus clean TRAPDOOR FAULTY Burn pot dirty or clogged p The door is not closed correctly The automatic burn pot cleaning is blocked If the proble
22. em safety dissipation system incorporated with the generator with thermal safety valve self activated whenever the appliance does not have a temperature self adjustment system DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection Whenever the generators lack a device those missing can be installed on the generator flow pipe within a distance no greater than 1 m from the machine COMMISSIONING CHECKS Before connecting the boiler a wash all system piping thoroughly in order to remove any residues which might compromise the correct functioning of certain system components pumps valves etc b check to verify that the flue has adequate draught that it is not narrowed and that other appliances do not discharge into the flue This is to prevent unexpected power increases The flue fitting can be mounted between the boiler and the flue only after this inspection An inspection of the connections with pre existing flues is recommended ANTI CONDENSATION DEVICE MANDATORY Make sure a suitable anti condensate circuit has been realised which guarantees an appliance return temperature of at least 55 C The automatic thermostatic valve for instance is used in solid fuel boilers as it prevents cold water from returning into the exchanger A high return temperature allows efficiency improvement reduces formation of smoke
23. enus up to the initial status ADJUSTING TIME DAY MONTH AND YEAR Set clock allows the user to adjust the time and date SET CLOCK CONTROLS PROCEDURE DAY MON TUE WED SUN Press key 6 HOURS 0 23 Proceed by pressing key 2 until the word SETTINGS is displayed MINUTES 00 59 Confirm using key 6 DATE 231 Confirm SET CLOCK with key 6 3 Use keys 4 or 5 to set and key 2 to move forward to adjust the hours minutes day MONTH 1 12 month and year YEAR 00 99 Press key 1 several times to confirm and exit the menu ADJUSTING LANGUAGE It is possible to select the preferred language to display the various messages SET LANGUAGE CONTROLS PROCEDURE ITALIAN Press key 6 ENGLISH Proceed by pressing key 2 until the word SETTINGS is displayed LANGUAGE GERMAN Confirm using key 6 FRENCH Proceed by pressing key 2 until LANGUAGE is displayed Confirm using key 6 SPANISH Use keys 4 or 5 to set the language Press key 1 several times to confirm and exit the menu OTHER FUNCTIONS AIR DISCHARGE This function allows the user to bleed any air in the stove Once the function has been activated the pump indicator light is activated on the display for 15 minutes 30 seconds the pumps will be powered alternating with 30 seconds of downtime To activate the function With the stove OFF press keys 1 and 4 at the same time enter the password 77 using keys 4 and 5 and
24. er switch The socket must be easily accessible The electrical system must be compliant with standards The efficiency of the earthing circuit must be checked Unsuitable earthing of the system can cause malfunctioning for which the manufacturer will not be held liable Power supply variations beyond 10 can cause faulty operation of the product 8 ENGLISH OExtraflame PELLETS AND FEEDING Pellets are made by applying high pressure to sawdust or wood waste products not containing paint from sawmills carpentry and other activities related to processing and working with wood Given that it does not use any glue to hold it together this type of fuel is completely environmentally friendly In fact the compactness of the pellets over time is guaranteed by a natural substance found in the wood itself wood coal In addition to being an environmentally friendly fuel in that it pushes wood residues to the limits pellets also have technical advantages While wood has a calorific value of 4 4kWh kg with 15 humidity after around 18 months of seasoning the calorific value of pellets is 5 kWh kg Pellet density is 650kg m3 and the water content is equal to 8 of its weight For this reason they do not require seasoning in order to arrive at a sufficiently adequate degree of heat yield The pellets used must comply with the characteristics described by the following standards ENPLUS UNIEN 14961 2 UNI EN ISO 17225 2 class A1 or A2 The
25. erline accessories of the manufacturer the connection must be carried out by the technician enabled directly in the board Contact the dealer for further details ENGLISH 19 OExtraflame CLEANING AND MAINTENANCE ALWAYS FOLLOW THE INSTRUCTIONS IN MAXIMUM SAFETY CONDITIONS Make sure the power cable s plug has been pulled out as the generator might have been programmed to turn on Make sure all the parts of the generator are cold The ashes are completely cold Ensure enough ventilation in the room when cleaning the product Poor cleaning affects correct operation and safety MAINTENANCE To ensure correct operation the generator must undergo routine maintenance by a qualified technician at least once a year Periodic inspection and maintenance operations must always be carried out by specialised technicians who are authorised and work in accordance with current regulations and the instructions reported in this user and maintenance manual EVERY YEAR HAVE THE FLUE EXHAUST SYSTEM SMOKE DUCTS AND T SHAPED FITTINGS SUPPLIED AND INSPECTION PLUGS CLEANED IF THERE ARE ANY BENDS AND ANY HORIZONTAL SECTIONS C THE CLEANING SCHEDULE FOR THE GENERATOR IS ONLY MEANT AS A GUIDE IT DEPENDS ON THE QUALITY OF THE PELLETS USED AND HOW OFTEN THE EQUIPMENT IS USED THESE STEPS MAY NEED TO BE PERFORMED MORE OFTEN PERIODICAL CLEANING TO BE CARRIED OUT BY THE USER As specified in this user and maintenance manual periodic cleaning operations must
26. greater safety especially if there are any children around remove the power supply cable Routine maintenance must be performed at least once a year C IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE REPLACED BY THE AFTER SALES SERVICE OR BY A SIMILARLY QUALIFIED PERSON SO AS TO AVOID ALL RISKS 22 ENGLISH OExtraflame ROUTINE MAINTENANCE The images are for illustration purposes Fumes motor disassembly and cleaning and fumes pipe and T new silicone in required points Inspections of gaskets ash drawer and door replace them and apply silicone where required Combustion chamber amp heat exchanger full cleaning and ignition plug duct cleaning Tank complete emptying and cleaning Room air fan disassembly and removal of dust and any pellet debris Air intake pipe inspection and any flow sensor cleaning IN ES IS JIN 119 IS 000000 ENGLISH 23 OExtraflame DISPLAYS DISPLAY REASON OFF Genera
27. he following graph shows the behaviour of the circulator pump 1 used on our thermo products at the speeds that can be set poo 0 0 0 5 1 1 5 2 2 5 3 3 5 Flow rate m h 6 ENGLISH OExtraflame INSTALLATION GENERAL The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards The installer must provide the owner or person acting for him according to the legislation in force with the declaration of conformity supplied with 1 the use and maintenance manual of the appliance and of the system components such as for example the smoke ducts chimney etc 2 photocopy or photograph of the chimney plaque 3 system booklet where applicable The installer must ask to be issued with a receipt stating that the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium s administrator must be requested COMPATIBILITY Installation in premises with fire hazards is forbidden Installation in residential premises except for sealed operation appliances is also forbidden in which there are liquid fuel operated appliances with continuous or intermittent operation which draw the combustion air in the room in which they are installed or inwhich there are type B
28. lems owing to the quantity of pellets adjust pellet feeding directly from the control board The problems correlated to the amount of fuel can be divided into 2 categories NO FUEL the stove is never able to develop a suitable flame tending to remain very low even at high power at minimum power the stove tends to almost switch off putting the stove in NO PELLETS alarm conditions when the stove displays the NO PELLETS alarm there may be non burned pellets inside the burn pot EXCESS FUEL the stove develops a very high flame even at low power the panoramic glass is very dirty obscuring it almost totally the burn pot tends to become encrusted blocking the holes for air intake due to excessive pellet loading as it is only burned partially The adjustment to be performed is in percentages Therefore changing this parameter will lead to a proportional variation of all stove feeding speeds Feeding is from 30 to 20 CONTROLS PROCEDURE Press key 6 Proceed by pressing key 2 untilUSER MENU is displayed Confirm using key 6 Press key 2 until PELLET is displayed Use keys 4 increase 5 to 4 or decrease 5 the load during the WORK stage Press key 1 several times to confirm and exit the menu 6 SET CHRONO This stage is used to program when the generator automatically turns on and off The factory setting for SET CRONO is disabled on the generator The chrono allows the user to program
29. ly programming disabled amp Indicates the contact of the external additional thermostat Closed contact on the contact of the external additional thermostat is closed Indicates the water temperature status Open contact on the contact of the external additional thermostat Off the T read by the probe is above the set temperature is open On the T read by the probe is below the set temperature Flashing with contact closed the contact of the external additional thermostat is closed and the STBY function is activated Flashing with contact open the contact of the external additional thermostat is open and the STBY function is activated It indicates fumes motor operation SX Off fumes motor disabled i On fumes motor active Flashing breakdown contact technical after sales service It indicates tangential fan operation where applicable 0 9 Off not working working Flashing motor at minimum Lut za It indicates pellet feed motor operation E Off pellet feed motor disabled On pellet feed motor active 1 Ss ge EE 1 o 1 It indicates pump operation Off pump deactivated On pump active Flashing the safety device is active H2O temperature gt 85 C 4 10 ENGLISH OExtraflame GENERAL MENU 1 Go back exit 2 Parameter scrolling nex
30. m persists contact the service centre ALL MIN H20 PRES SURE The system pressure read by the pressure switch is too low Possible air in the system vent the system Possible lack of water or leaks due to anomalies in some system component If the problem persists contact the service centre H20 PROBE H20 probe failure Contact after sales centre ALL MAX H20 PRES The pressure of the water has exceeded the max Possible air in the system vent the system Check that the expansion vessels are not damaged or under dimensioned on applicable models SURE threshold Check that the cold system is loaded at the correct pressure If the problem persists contact the service centre PRESSURE SENSOR Defective disconnected or faulty differential esse FAULTY Pressure sensor AUGER CONTROL Anomalous pellet loading Contact after sales centre AUGER BLOCK Anomalous functioning of the motor Contact after sales centre BOILER PROBE Boiler probe failure Contact after sales centre PUFFER PROBE Boiler probe failure Contact after sales centre The pellet feed box is empty Check for the presence of pellets in the feed box Check hermetic door closure Thedeor shor closed covertly Check hermetic closure of the ash drawer TANK EMPTY The ash drawer is not closed correctly The combustion chamber is dirty The flue exhaust pipe is blocked ENGLISH Check cleanliness of the fumes pipe of the
31. manufacturer always recommended using pellets with a diameter of 6 mm with its products PELLET STORAGE In order to ensure problem free combustion pellets must be stored in a dry place Open the tank lid and load the pellets using a scoop THE USE OF EXPIRED PELLETS OR ANY OTHER MATERIAL WILL AFFECT THE FUNCTIONALITY OF YOUR C GENERATOR AND MAY LEAD TO THE TERMINATION OF THE WARRANTY AND CESSATION OF ANY ACCOMPANYING RESPONSIBILITY ON THE PART OF THE MANUFACTURER CHECKS AND PRECAUTIONS FOR FIRST IGNITION IMPORTANT IN ORDER FOR THE GENERATOR TO WORK PROPERLY THE HYDRAULIC SYSTEM S PRESSURE MUST BE BETWEEN 0 6 AND 2 5 BAR If the pressure detected by the digital pressure switch is below 0 6 or above 2 5 bar it triggers a boiler alarm Bringing the water pressure within the standard values it is possible to reset the alarm by pressing the button ba for 3 seconds The alarm can be reset only if the fumes motor has stopped and 15 minutes have elapsed from the display of the alarm THE PELLET LOADING MOTOR DOES NOT WORK Due to the filling of the system it is normal that there is air inside the circuit During the 1st ignition cycle water movement causes the displacement of air bubbles and their out flow from the automatic vents out of the system This can cause the pressure to drop and activate the minimum pressure switch which stops the motor that transports the pellets and therefore the heat generator Vent out the
32. ng with the external thermostat connected in the STBY clamp can be different on the basis of the activation or disabling of the STBY function The STBY clamp leaves the factory jumpered therefore it is always with closed contact on request ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE When the STBY function is activated the o o LED flashes When the contact or external thermostat is satisfied open contact temperature reached the stove will switch off As soon as the contact or external thermostat switches to the not satisfied status closed contact temperature to be reached it will re ignite N B stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY DEACTIVATED When the STBY function is disabled the o o LED is fixed When the contact or external thermostat is satisfied open contact temperature reached the stove will go to minimum As soon as the contact or external thermostat switches to the not satisfied status closed contact temperature to be reached the stove will start to work again at the pre set power N B stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional con
33. nt circuit breaker switch managed by board program Pressure transducer with minimum and maximum pressure switch alarm Water overheating automatic circuit breaker switch block thermostat Circulation system pump S NISISIS Expansion system INSTALLATION AND SAFETY DEVICES The installation relative system connections commissioning and inspection of correct functioning must be carried out with the highest professional standards in full compliance with the national regional and council Standards in force as well as these instructions For Italy installation must be carried out by professionally authorised staff Ministerial Decree dated 22 01 08 n 37 The Manufacturer declines all liability for damage injury to objects persons caused by the plant TYPE OF SYSTEM There are 2 different types of system Open vessel system and closed vessel system The product has been designed and made to work with closed vessel systems CHECK THAT THE PRELOAD OF THE EXPANSION VESSEL IS SET TO 1 5 BAR SAFETY DEVICES FOR CLOSED VESSEL SYSTEM According to Standard UNI 10412 2 2009 in force in Italy closed systems must be equipped with safety valve pump control thermostat acoustic alarm activation thermostat temperature indicator pressure indicator acoustic alarm regulation automatic circuit breaker switch automatic circuit breaker block switch block thermostat circulation system expansion syst
34. ong as the flow takes place freely through permanent openings communicating with the outside The adjacent room cannot be used as a garage or to store combustible material or for any other activity with a fire hazard bathroom bedroom or common room of the building FLUE GAS EXHAUST The heat generator works in depression and is equipped with an outlet fan for flue gas extraction There must be a single exhaust system for the generator Using a flue that is shared with other devices is not allowed The components of the flue gas exhaust system must be chosen in relation to the type of appliance to be installed in compliance with UNI TS 11278 in the event of metal chimneys with particular attention to that stated in the specification UNI EN 13063 1 and UNI EN 13063 2 UNI EN 1457 UNI EN 1806 in the event of non metallic chimneys The length of the horizontal section must be minimal and in any case no longer than 3 metres with a minimum upward slope of 396 There must not be more than 4 direction changes including the one due to the use of the T element A T fitting with a condensation collection cap must be provided at the base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the building If the smoke duct is inserted in an existing flue it must be certified for solid fuel If the smoke duct is outside th
35. ous avoiding overheating blocks Normally this area is defined as a Safety zone ENVIRONMENTAL TEMPERATURE in the applicable models The front ventilation can be activated deactivated and the room temperature controlled by means of the room probe as per standard See the enable fan chapter on the following pages BURN POT CLEANING During the work stage the stove has an internal counter which cleans the burn pot after a set amount of time This stage will be shown on the display it will bring the stove to a lower power level and will increase the fumes motor for a programmed amount of time When the cleaning stage is finished the stove will continue its work going back to the selected power level MODULATION and H OFF As the water temperature approaches the set point the boiler starts to modulate automatically bringing itself to the minimum power If the temperature increases beyond the set point it will automatically switch off indicating H OFF and will automatically go back on when the temperature drops below the set point SWITCH OFF Press key 1 for three seconds When the operation has been performed the appliance automatically enters the switch off phase blocking the supply of pellets The fumes motor and the hot air ventilation motor will remain on until the temperature of the stove has dropped below the factory parameters RE IGNITION The stove can only be re ignited automatically or manually when the cooling cycl
36. system if necessary even multiple times to remove the air and reload it if the pressure is too low It is not a malfunction but a normal occurrence due to its filling After filling the plumber must always thoroughly vent the system using the special vents in the circuit and running the air breather function on the machine After the first ignition and with a cold machine re activate the function air breather see chapter OTHER FUNCTIONS BULB THERMOSTATS RESET Check by pressing the reset buttons 85 100 C located on the back of the appliance before contacting a technician see section RESET ENGLISH 9 OExtraflame CONTROL PANEL BUTTON DISPLAY OF VARIOUS TO ACCESS ON OFF TEXT MESSAGES THE MENU 1 1 ADJUSTMENT SETTING OPERATING POWER TEMPERATURE DISPLAY ICONS KEY Indicates the stove modulation On the stove is working at the set power Flashing the power at which the stove is working is different to the power set the stove is modulating for various reasons Indicates the receipt of the radio signal On during radio communication Off no radio communication Flashing serial port excluded ER a EN Indicates the presence of an alarm On indicates the presence of an alarm Off indicates the absence of alarms Flashing indicates the deactivation of the depression sensor It indicates weekly programming functioning Indicator on weekly programming active Indicator off week
37. t 2 previous 3 4 5 Modify settings data increase 4 decrease 5 6 Confirm access Menu SET POWER POWER SET TEMPERATURE ROOM AIR TEMP SET i SET H20 USER MENU ENABLE V1 AIRV1 SET CHRONO f ENABLE CHRONO RESET ENABLE PRG1 PELLET ENABLE PRG2 STATUS e STOVE STATUS ENABLE PRG3 ENABLE PRG4 SETTINGS gt SET CLOCK START PRG1 LANGUAGE STOP PRG1 DISPLAY MONDAY PRG STAND BY SUNDAY PRG1 SET PRG1 WHERE PRESENT MENU TECHNICIAN SAME STEPS FOR THE OTHER ONES RESERVED TO THE 3 TIME SLOTS TECHNICIAN BASIC INSTRUCTIONS The following recommendations must be followed the first times the stove is ignited Faint smells may be produced due to the drying of the paints and silicones used Do not remain in the environment for long periods not touch the surfaces as they could still be unstable Airthe room well several times The hardening of the surfaces is terminated after several heating processes Thisappliance must not be used to burn waste Before lighting the stove the following points must be verified The hydraulic system must be completed in compliance with the guidelines of the regulations and the manual The tank must be full of pellets The combustion chamber must be clean The burn pot must be completely free and clean Check the hermetic closure of
38. t by pressing this key 7 ENABLE DELAYED For example if the stove is set to switch off in an hour it shall switch off SWITCH OFF automatically once the set time elapses displaying the countdown every minute for delayed automatic shutdown 8 MENU This key allows the user to access the user and technical menu the technical menu is reserved for assistance 9 INCREASE The temperature setting can be increased by pressing this key 10 ESC KEY hi e or display and returns to the 11 BACK The key returns to the display of the various menus 12 CONFIRMATION KEY adjustments made during the user menu 13 FORWARD The key allows the user to go forward in the various menus 14 ENABLE FUNCTION F1 Pre set key for future applications 15 DECREASE The key decreases the value to be set 16 STOVE STATUS Pressing this key will display the general status of the stove Important note the numbers shown on the remote control are purely indicative and are not present on the remote control supplied with the product TYPE AND REPLACEMENT OF BATTERIES The batteries are housed in the lower part of the remote control To replace it you need to take out the battery holder remove or insert the battery following the symbols on the remote control and on the battery For operation 1 CR2025 3V lithium buffer battery is required The batteries used contain metals harmful for the environment They must therefore be disposed of separa
39. tact or thermostat request will be ignored ADDITIONAL THERMOSTAT INSTALLATION Switch the appliance off using the master switch positioned on the rear of the stove Remove plug from the socket Refer to the electrical layout to connect the two thermostat cables to the relative clamps positioned on the rear of the machine one is red and the other black STBY clamp Every model can have a different position of the relative clamps in the rear of the machine The image is given as an example 7 REFERTO THE SETTINGS CHAPTER TO ACTIVATE STAND BY au Qo HE 6 ENGLISH 15 OExtraflame SET POWER The following menu allows you to set the generator power Minimum power 1 maximum power 5 CONTROLS PROCEDURE Press key 6 Confirm using key 6 SET POWER Use keys 4 or 5 to set the power Press key 1 several times to confirm and exit the menu TEMPERATURE SET The following menu allows you to set The room temperature from OFF 06 40 C for intended models The room temperature will be displayed alternately with the water temperature on the display The boiler temperature from 65 80 C CONTROLS PROCEDURE Press key 6 Proceed by pressing key 2 until TEMPERATURE SET is displayed Confirm
40. tely in appropriate containers IF THE REMOTE CONTROL IS OFF BECAUSE IT HAS NO BATTERIES THE STOVE CAN BE CONTROLLED FROM THE CONTROL PANEL ON TOP OF IT WHILE REPLACING THE BATTERY PAY ATTENTION TO THE POLARITY BY OBSERVING THE SYMBOL ON THE INSIDE COMPARTMENT OF THE REMOTE CONTROL ALL CLEAN CHECK UP SHOULD THE ALL CLEAN CHECK UP ALARM BE TRIGGERED MAKE SURE THAT THE BOTTOM OF THE BURN POT IS FREE OF RESIDUES OR SCALES 25 THE HOLES AT THE BOTTOM MUST BE COMPLETELY FREE GUARANTEE CORRECT COMBUSTION ONE CAN USE THE FUNCTION TO ADJUST COMBUSTION BASED ON THE DESCRIBED REQUIREMENTS IF THE ALARM PERSISTS AND THE ABOVE LISTED CONDITIONS HAVE BEEN CHECKED CONTACT THE QUALIFIED AFTER SALES ASSISTANCE CENTRE 12 BURN POT BOTTOM ENGLISH OExtraflame COMMISSIONING SETTINGS Once the power cable at the back of the stove has been connected move the switch also located on the back to 1 The switch at the back of the stove powers the stove board The stove remains off and a first screen appears on the panel reading OFF MAINS FREQUENCY 50 60HZ In the event the stove is installed in a country with 60Hz frequency the stove will display frequenza rete errata mains frequency incorrect Vary the frequency as described below CONTROLS PROCEDURE Press key 6 Select the frequency required using key 4 or 5 Press key 6 to confirm and key 1 to return to the previous m
41. the fire door and the ash drawer Check that the power supply cable is connected correctly The bipolar switch in the rear right part must be positioned on 1 999 The company has an optional additional board that allows the boiler the following further functions when managing the system The table below indicates the various possibilities that the optional can offer DHW Storage Management Puffer Management 3 heating areas Instant DHW option Puffer pump or 4th heating area management Anti legionella management for DHW storage DHW storage chrono management Auxiliary output management and control SISISISIS SI SIS ENGLISH 11 OExtraflame THE REMOTE CONTROL All that can normally be implemented through the LCD can be adjusted using the remote control The table below provides a detailed description of the various functions 2 o LOP KC 1 ON OFF Pressing the key for three seconds the stove will switch on or off 2 POWERINCREASE Pressing the key will increase the operating power 3 POWER DECREASE Pressing the key will decrease the operating power 4 T INCREASE The temperature setting can be increased by pressing this key 5 T DECREASE The set temperature can be decreased by pressing this key 6 CORDES bode Pressing the key once will enable or disable the chrono The delayed switch off can be se
42. tor off START The start up phase is in progress PELLET FEEDING Continuous pellet feeding is in progress during the ignition phase IGNITION The ignition phase is in progress START UP The start up phase is in progress WORK The normal work phase is in progress MODULATION The generator is working at minimum BURN POT CLEANING Automatic burn pot cleaning is in progress BURN POT CLEANING DEPRESSION Automatic burn pot cleaning is in progress due to insufficient depression FINAL CLEANING The final cleaning is in progress STAND BY Generator off waiting for re ignition due to an external thermostat A new ignition is attempted when the generator has just been switched off When the generator switches off one must wait for STAND BY n the complete shutdown of the fumes motor then clean the burn pot The generator can only be re ignited when these operations COOLING have been performed HOFF Generator off due to water temperature over set T AMB Displays room temperature in the models designed for it T OFF Generator off waiting for re ignition as all the requests have been satisfied STAND BY The generator is cooling after a power cut BLACK OUT Once cooling is completed it will re start automatically ANTI FREEZE The anti freeze function is in progress as the 2 t is below the factory set threshold the pump is active until the water reaches the pre set factory parameter 2 C The pump antilock fun
43. uExtraflame Riscaldamento a Pellet THERMO PRODUCTS USER MANUAL MELINDA IDRO OExtraflame 2 ENGLISH OExtraflame NKEA E o AE EE E S E E ET T 4 WARNINGS 220200000000r0000000n000nrsnnnennnsnnnennnnsnnnsnansnnnnsnnssnnnsnnnsnnnnennnsnnnsnnnssnnnsnnnsnnnsnnnssnnnsnnssnnnssnnnsnnnsnnnssnnnsnnsssnnsnnnsnnnssnsssnnssnnssnnnsnnee b 7 Xi GEY ROUTINE M PU INSTALLATION AND SAFETY ANTI CONDENSATION DEVICE MANDATORY INSTANT DOMESTIC HOT WATER PRODUCTION KIT STOVE POSITIONING e DESSANT MS y n THERMO PRODUCTS FEATURES INSTALLATION GENERAL PELLETS AND FEEDING CHECKS AND PRECAUTIONS FOR FIRST seen setenta seas sees sess tasa etna esses sensa one 9 THE PELLET LOADING MOTOR DOES WORK ettet teri nes ee nie 9 BULB THERMOSTATS RESET etti trier tb rte CER Ue to T te ue EON ION EST TEM NIE ERU HOD ee 9 CONTROL DISPLAY 5

Download Pdf Manuals

image

Related Search

Related Contents

Cabeamento estruturado  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file