MS9A-24HRDN1-MS0W installation manual-ok.cdr

image

Contents

1. Correct Barrier JS x Strong wind NOTE The drain joint is slightly different according to the different outdoor unit For the drain joint with the seal Fig A first fit the seal onto the drain joint then insertthe drain joint into the base pan hole of outdoor unit rotate 90 to securely assemble them Toinstall drain joint as shownin Fig B insert the drain joint into the base pan hole of outdoor unit until it remains fixed with a clicking sound Connecting the drain joint with an extension drain hose Locally purchased in case of the water draining off the outdoor unit during the heating mode Base pan hole in joint gee of outdoor unit Flaring 1 Cut a pipe with a pipe cutter 2 Remove flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal and flare the pipe Firmly hold copper pipe in a die in the dimension shown in the table below ae elt ZC JOOU ACO Outer diam mm 6 6 35 i lt Fp _ A4nRe 9 52 Ip ID z 6 12 7 i j Indoor unit tubing Flare nut Pipings Outer Tightening Additional tightening diam torque N cm torque N cm 1500 1600 amp 6 35mm 153kgf cm 163kgf cm 2500 9 52mm 255kgf cm Tighteningconnection Align pipes to be connected e Sufficiently tighten the flare nut with fingers and then tighten it with a span
2. Drainage 1 Run the drain hose sloping downward Do not install the drain hose as illustrated in Figures 2 When connecting extension drain hose insulate the connecting part of extension drain hose with a shield pipe do not let the drain hose slack Connective pipeinstallation For the left hand and right hand piping remove the pipe cover from the side panel For the rear right hand and rear left hand piping install the piping as shown Bundle the tubing connecting cable and drain hose with tape securely evenly as shown in Figure on the right Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room Do not put anything else in the box CAUTION Connect the indoor unit first then the outdoor unit Do not allow the piping to let out from the back of the indoor unit Be careful not to let the drain hose slack Heat insulated both of the auxiliary piping Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Never intercross nor intertwist the power wire with any other wiring Run the drain hose slopped downward to drain out the condensed water smoothly Indoor unit installation 1 Pass the piping through the hole in the wall 2 Hook the indoor unit onto the upper portion of installation plate Engage the indoor unit with the upper edge of the
3. Lo packed valve B Hi packed valve C and D are ends of indoor unit connection 4 Test running Perform test operation after completing gas leak check at the flare nut connections and electrical safety check Check that all tubing and wiring have been properly connected Check that the gas and liquid side service valves are fully open 1 Connect the power press the ON OFF button on the remote controller to turn the unit on 2 Use the MODE button to select COOL HEAT AUTO and FAN to check if allthe functions works well 3 When the ambient temperature is too low lower than 17 C the unit cannot be controlled by the remote controller to run atcooling mode manual operation canbe taken Manual operation is used only when the remote controller is disable or maintenance necessary Hold the panel sides andlift the panel up toan angle until it remains fixed with a clicking sound Press the Manual control button to select the AUTO or COOL the unitwill operate under Forced AUTO or COOL mode see User Manual for details 4 The test operation shouldlast about 30 minutes Manual control Button o AUTOZOOL CS 1451 BPC12 H
4. any noncondensables and moisture from the system Check that each tube both liquid and gas side tubes between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed Pipe length and refrigerant amount Connective pipe length Air purging method Additional amount of refrigerant to be charged Less than 5m Use vacuum pump Liquid side 6 6 35mm Liquid side 6 9 52mm R22 Pipe length 5 x30g m R22 Pipe length 5 x60g m R410A Pipe length 5 x20g m R410A Pipe length 5 x40g m More than 5m Use vacuum pump For the R407C refrigerant model make sure the refrigerant added into air conditioner is liquid form in any cases e When relocate the unit to another place using vacuum pump to perform evacuation CAUTION Open the valve stem until it hits against the stopper Do not try to open it furher Securely tighten the valve stem cap with a spanner or the like e Valve stem cap tightening torque See Tightening torque table Refrigerant Flare nut Outdoor ni unit A Gasside _ c iquid side p Packed valve Valve body Half union Valve stem 2 Whenusing theVacuumPump 1 Completely tighten the flare nuts A B C D connect the manifold valve charge hose to a charge port of the packed valve on the gas pipe side Connect the charge hose connection to the vacuum pump Fully open the handle Lo of the manifold valve Operate
5. installation plate Ensure the hooks are properly seated on the installation plate by moving it in left and left Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping Press the lower left and right side of the unit against the installation plate until hooks engages with the their slots above th Do not put the end of drain hose into water 1 The Do not block water flow by a rise Move and tape the drain hose with piping in a position as mentioned in Fig Below Cover for the left piping right piping Cover for piping Pipe holder Pipe cover Left piping Pipe cover Left back piping Right piping Right back piping Ponding box Pipe room Connective pipe Wrapping belt Drain hose Upper Hook Cushioning Lower Hook material CONNECT THE CABLE TO THE INDOOR UNIT Electrical work Electric safety regulations for theinitial Installation 1 If there is serioussafety problem about the powersupply the techniciansshould refuse to install the air conditioner and explainto the client until the problem is solved 2 Power voltage should bein the range of 90 110 of rated voltage 3 The creepage protector andmain power switch with a1 5 times capacity of Max Current of the unit should be installed in powercircuit 4 Ensure the air conditioneris grounded well 5 A
6. INSTALLATION MANUAL FOR ROOM AIR CONDITIONER Split Wall Mounted Type QELOBAL globalindustrial com Model 600CP517A 600CP517B SAFETY PRECAUTIONS Please read this installation manual completely before installing the product If the power cord is damaged replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring Standards by authorised personnel only Contact an authorised service technician for repair maintenance or installation of this unit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance All the pictures in the instructions are for explanation purposes only The actual shape should prevail The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details m Theseriousness is classified bythe following indications A WARNING A CAUTION This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property ZA WARNING 1 Install according to this
7. are the same to the indoor s respectively 5 Wrap those cables notconnected with terminals with insulation tapes so that they willnot touch any electrical components Secure the cable onto the control board with the cord clamp a 2Z2 C DTO0CVZ Terminal block of indoor unit gle es e 1 2 S Li 2 SQ le lelele elelalele gt _9 To outdoor unit Electrical box cover To outdoor unit OUTDOOR INSALLATION PRECAUTION e Install the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction where the discharged air is not blocked In the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram The installation wall should be solid brick concrete or the same intensity construction or actions to reinforce damping supporting should be taken The connection between bracket and wall bracket and the air conditioner should be firm stable and reliable Be sure there is no obstacle which block radiating air Incorrect
8. ccording tothe attached Electrical Connection Diagram located on the panel of the outdoorunit and indoor unit to connectthe wire 6 An individual branch circuitand single receptacle used onlyfor this air conditioner mustbe available See the following table for suggested wire sizes Minimum norminal cross sectionalarea of conductors Rated current Nominal cross sectional NOTE ofappliance area A mm2 The cable size and the current of thefuse or switch are determined by the maximum gt 3 and lt 6 0 75 current indicated on the nameplate which gt 6 and lt 10 1 located on the side panel of the unit gt 10 and lt 16 15 ed ea ee eh gt 16 and lt 25 2 5 g i i gt 25 NOTE The airconditioner can be connected only toa supply with system impedance no more than 0 0538 ohm In case necessary please consult your supply authority for system impedance information Connect thecable tothe indoorunit NOTE Before performing any electrical work turn off the main powerto the system 1 The inside and outside connecting cable can be connected without removing the front grille 2 The indoor power cordtype is HOS5VV F or HO5V2V2 F the outdoor power cord and interconnected cord type is HO7RN F 3 Lift the indoor unit panel up remove the electrical box cover by loosening the screw 4 Ensure the colour of wires of outdoor unit andthe terminal Nos
9. installation instructions strictly Ifinstallation is defective it will cause water leakage electrical shock fire 2 Use the attached accessories parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock fire 3 Install at a strong and firm location which is able to withstand the sets weight If the strength is not enough or installation is not properly done the set will drop and cause injury 4 For electrical work follow the local national wiring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock fire 5 Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 6 Wiring routing must be properly arranged so that control board cover is fixed properly If control board cover is not fixed perfectly it will cause heat up at connection point of terminal fire or electrical shock 7 When carrying out piping connection take care not to let air substances other than the specified refrigerant go into refrigeration cycle Otherwise it will cause lower capacity abnormal high pressure in the refrigeration cycle explosion and injury 8 Do not modify the length of the power
10. l or plant which could be affected by hotair discharged Keep the spaces indicated by arrow from wall ceiling fence or other obstacles Do not place any obstacles which may cause a short circuit of the discharged air Settlement of outdoorunit Anchor the outdoor unit witha bolt and nut 10 or 68 tightly and horizontally on a concrete or rigid mount 60cm or more Mountingdimensions L2 mm W2 mm 481 276 530 290 600 320 523 340 560 335 590 333 Outdoor unitdimension mm L1xHxW1 670x540x250 760x590x285 775x545x310 820x595x330 845x700x320 900x860x315 ACCESSORIES Name of Accessories Qty Installation Plate 1 Clip Anchor 5 8 depending onmodels Self tapping Screw A ST3 9x25 5 8 depending onmodels Seal For cooling amp heating models only Drain Joint For cooling amp heating models only jquidsi 06 35 Connecting Liquidside pipe Assembly Parts you must purchase The pipe size differ from appliance to appliance Consult the technician for the proper size Gasside 019 Remote controller Self tapping Screw B ST2 9x10 Remote controller holder NOTE Except the above parts provided the other parts needed during installation you must purchase optional parts l N D 0 0 R U N l T FIT THE INSTALLATION PLATE NOTE The mounting wall is stro
11. ner and torque wrench as shown Excessive torque can break nut depending on installation conditions 2600 265kgf cm 3600 367kgf cm 3500 12 7mm 357kgf cm 4500 4700 o 16mm 459kgf cm 479kgf cm 6500 6700 19mm _ 663kgf cm 683kgf cm CONNECT THE CABLE TO THE OUTDOOR UNIT Remove the electrical control board cover from the outdoor unit by loosening the screw Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units Secure the cable onto the control board with the cord clamp To prevent the irgress of water form a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units Insulate unused cords conductors with PVC tape Process them so they do not touch any electrical or metal parts Terminal block of outdoor unit o Toindoor unit Topower supply Toindoor unit 1 2 Topower supply AIR PURGING AND TEST OPERATION 1 Airpurging e Air and moisture in the refrigerant system have undesirable effects Therefore the indoor unit and tubing between the indoorand outdoor unit must beleak tested and evacuated toremove
12. ng and solid enough to prevent it from the vibration Fitthelnstallation Plate 1 NOTE Correct orientation of Installation Plate Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate If the wall is made of brick concrete or the like drill eight 8 5mm diameter holes in the wall Insert Clip anchor for 150 or more from i appropriate mounting screws Fit the installation plate on the wall with eight 8 type A screws 120mm or more from the wall 1D Os 120mm or more from the wall Fit the Installation Plate and drill Ww holes in the wall according to the wall structure and corresponding mounting points on the installation Pipe hole plate The installation plate provided with the machine differ from appliance to appliance Dimensions are in mm unless otherwise stated Determine hole positions according to left and right side of the installation plate The hole center is obtained by measuring the distance as shown in the diagram Dirll the piping plate hole with 665mm hole core drill Drill the piping hole at either the right orthe left and the hole should be slightly slanted to the outdoor side Always use wall hole conduit when drilling metal grid metal plate or the like
13. supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock CAUTION 1 This equipment must be earthed and installed with earth leakage current breaker It maycause electrical shock if grounding is not perfect 2 Do not install the unit at place where leakage of flammable gas may occur Incase gas leaks and accumulates at surrounding of the unit it may cause fire 3 Carry out drainage piping as mentioned in installation instructions If drainage is not perfect water may enter the room and damage the furniture SELECT THE BEST LOCATION Indoor unit There should not be any heat source or stream near the unit There should not be any obstacles blocking the air circulation e A place where air circulation in the roomis good A palce where drainage can be easily done A palce where noise prevention is taken into consideration Do not install the unitnear the door way Ensure the spaces indicated by arrows from the wall ceiling fence or other obstacles e There should not be any direct sunlight If unavoidable sunlight prevention should be takeninto consideration 45cm or more 2 3m or more Outdoor unit e f an awning is built over the unit to prevent direct sunsight or rain be careful that heat radiation from the condenser is not obstructed There should not be any anima
14. the vacuum pump to evacuate After starting evacuation slightly loose the flare nut of the packed valve on the gas pipe side and check that the air is entering Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus After the evacuation is complete fully close the handle Lo of the manifold valve and stop the operation of the vacuum pump e Make evacuation for 15 minutes and more and check that the compound meter indicates 76cmHg 1 0x10 Pa 6 Turn the stem of the packed valve B about 45 counter clockwise for 6 7 seconds after the gas coming out then tighten the flare nut again Make sure the pressure display in the pressure indicator is a little higher than the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve Manifold valve Compound meter Pressure gauge Handle Lo Charge hose gt charge hose Vacuum pump Packed valve 3 Safetyand leakagecheck Indoor unit 1 Soap water method 2 Leak detector check point Apply a soap water or a liquid neutral detergent on the indoor unit connections and outdoor unit connections by a soft brush to check for leakage ofthe connecting points of the piping If bubbles come out it indicates that the pipes have leakage Outdoor check point Use the leak detector to check for leakage CAUTION A