Home
Manual
Contents
1. Low power indication 14 Output state indication 15 Output state indication 16 Reading value 17 Unit indication 18 Mode indication Operation Instructions RTD measurement D Press the power key 5 turn on the calibrator 2 Press the Input Output key 8 when on the input mode 3 Press RTD mode key 6 on the measure type you want put the RTD or Resistance on the input jack D If you want to measure with 3W 4W mode press the wire mode select key 9 10 to select and put the wire to the correspond input Jack 6 cet the reading value 16 The number in the 5 referring to the Explanation on Front Panel Page 4 Illi WWW AXIOMET EU RTD Simulate D Press the power key 5 turn on the calibrator 2 Press the input output key 8 When on the output mode Press the RTD mode key 6 on the measure type you want H e Press the adjust value key 9 I 10 11 12 to let the value on your need Put the RTD meter or Resistance meter on the input Jack 6 If you want to output with 3W 4W mode put the other wire on the 2wir jack like the left picture D If you want to change the output value then press the adjust value key or change to other RTD type use the RTD mode key 6 9 10 11 12 The number in the O
2. AXIO i Hii MET HANDHELD DIGITAL CLAMP MULTIMETER AX C850 OPERATOR S INSTRUCTION MANUAL Safety Information To avoid possible electric shock or personal injury Never apply more than 30V between any two jacks or between any jack and earth ground Make sure the battery door is closed and latched before you operate the calibrator Remove test leads from the calibrator before you open the battery door Do not operate calibrator if it is damaged Do not operate the calibrator around explosive gas vapor or dust To avoid possible damage the calibrator Make sure choose the right jack and rang before use the calibrator to measurement or calibrator Take away the calibrator from the used circumstance before operate the calibrator or after close the calibrator Introduction RTD Process Calibrator is exactitude measurement and source instrument it can be use to calibrate the RTD transmitter include most impulse transmitter RTD Process Calibrator can measure or simulate 7 difference types of RTD C or F and measure or simulate the Resistance But it could not use to measurement or source at a same time The accessories 2 pair of test lead and alligator clip 6 AAA 1 5V battery user s manual If the Calibrator is broken or short of some accessories please contact the supplier The following table has showed the technical parameter and function of the Calibrator Specification All the specificati
3. on will under 1 year calibration cycle and temperature between 18 28 C except addition explain Measure input Simulate output Resistance specification Range Measure accuracy Simulate accuracy Admie excitation AW Q Q mA 0 15 0 1 0 5 0 00 Q 400 00 Q 0 1 0 1 0 5 3 0 400 0 Q 1500 0 0 0 5 0 5 0 05 0 8 1 1500 0 Q 3200 0 Q 2 1 0 05 0 4 RTD Resistance Temperature Detector Illi WWW AXIOMET EU Admit excitation current only apply on simulate mode The admit excitation current could be marked on the OHM meter or RTD meter which was connected to the calibrator Admit excitation current 0 2mA Measure input Simulate output RTD specification Max input voltage 30V Mode Range Accuracy C Admie excitation Input 4W Input 2W 3W Output mA Pt10 385 200 800 C Nie okreslana 0 1 3 0 328 1472 F Pt50 385 200 800 C 0 7 1 0 0 7 0 1 3 0 328 1472 F Pt100 385 200 800 C 0 33 0 5 0 33 0 1 3 0 328 1472 F Pt200 385 200 250 C 0 2 0 3 0 2 0 1 3 0 328 482 F 250 630 C 482 11669F 0 8 1 6 0 8 Pt500 385 200 500 C 0 3 0 6 0 3 0 05 0 8 328 932 F 500 630 C 932 1166 F 0 4 0 9 0 4 Pt1000 385 200 100 C 0 2 0 4 0 2 0 05 0 8 328 212 F 100 630 C 212 1166 F 0 2 0 5 0 2 Pt100 JIS 200 630 C 0 3 0 5 0 3 0 1 3 0 328 1166 F Admit excitation current only apply on simulate mode The admit excita
4. referring to the Explanation on Front Panel Page 4 OUTPUT 6000 LE T OUTPUT _ IW 34 4W xv WT e UA D at i oR ante A RTD S uw METER WWW AXIOMET EU Maintenance Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents Calibration Calibrate your calibrator once a year to ensure that it performs according to its specifications Replacing the Battery Please change the battery when the LCD indicates E Turn off the power of the Calibrator when you change the battery and screw off the breechblock on the battery cabinet cover then take off it and instead the fresh AAA 1 5 V battery Illi WWW AXIOMET EU
5. tion current be marked on the OHM meter or RTD meter which was connected to the calibrator Admit excitation 0 2mA Max input voltage 30V WWW AXIOMET EU General Specifications Maximum voltage applied between any jack and earth ground or between any tow jack 30V Resolution Storage temperature Operating temperature Operating altitude Temperature coefficient Relative humidity Shock Safety Power requirements Size Weight International Symbols RTD 0 1 C F Resistance 0 01 0 1 0 40 C 60 C 10 C 55 C 3000 meters maximum 0 01 C on 0 C 18 C and 28 C 50 C 95 up to 30 C 75 up to 40 C 45 up to 50 C 35 up to 55 C Random 2g 5Hz to 500Hz 1 meter drop test 6xAAA 1 5V Battery 205mmx98mmx46mm 472 g include battery Symbol Meaning l Earth ground Conform to European Union directives Refer to his instruction sheet for information about this feature Battery T A ES n Double insulation Explanation on Front Panel The front panel is show as in right figure 1 4wire input jack NC on output 2 2wire input output jack 3 2wire input output jack 4 3wire input jack NC on output 5 Power key WWW AXIOMET EU 6 RTD mode key 7 C F key 8 Input Output key 9 Increase more value key wire mode select 10 Reduce more value key wire mode select 11 Increase less value key 12 Reduce less value key 13
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment
Related Contents
Manual de usario Nord C2D MAN-051 Hydraulic Overflow Settlement Cell iiyama ProLite E2607WS Zoomax Snow 7 HD Manuel d`utilisation Fujitsu ESPRIMO E910 GPX C208B Clock Radio User Manual Copyright © All rights reserved.
Failed to retrieve file