1. shows that input voltage is high SLOW BLINK shows that input voltage is low OFF shows that input voltage is very low RECTIFIER The indicator is displayed rectifier status ON shows that rectifier operation is normal OFF shows that rectifier does not operate INVERTER The indicator is displayed inverter status ON shows that inverter operation is normal OFF shows that inverter does not operate AUTO BYPASS The indicator is displayed when load is consuming power from utility line It is possible that you connected more than 100 load to the UPS or INVERTER is malfunction ON shows that load is consuming power from utility line It is possible that you connected more than 100 load to UPS or INVERTER is malfunction SLOW BLINK shows that utility line voltage is abnormal Load is not consuming power from utility line 3 1 7 LOAD LEVEL The indicator displayed how much power UPS is supplying compare with its full capacity 3 1 8 BATTERY LEVEL The indicator displayed how much backup power stored in battery compared with full capacity of battery ON shows that power stored in batteries BLINK shows the black out load is consuming power from batteries 3 1 9 LOW BATTERY The indicator displayed when batteries are supplying power ON shows that power stored in batteries almost gone and UPS is ready toshutdown itself 3 1 10 OVER TEMPERATUER The indicator displayed when temperature inside the UPS is too high 3 1 11 FAULT The indicator d
2. USER S GUIDE LEONICS AN Authorized Distributor e nate X Ultimate X series id AN van poy fa Vi T QV gt UKAS WZ 7ERED si LE CONVER e www leonics com e e mail global busine onics come LEN MAN UPS 076 Rev 2 00 2003 LEONICS CO LTD A5043 ISO 9001 EMS 01007 045 CONTENTS Safety Instruction Introduction Front and Rear Panel Installation Operation Troubleshooting Customer Support Maintenance oO nwW oO 11 11 SAFETY INSTRUCTIONS a read and follow this user s manual carefully and completely b Important Please keep this user s manual for later reference It consists of Introduction Front and Rear Panel Installation and Operation Troubleshooting Customer Support and Maintenance If the UPS does not operate properly and you cannot solve the problem using the troubleshooting information in this user s manual please contact your LEONICS local distributors LEONICS Service Center send e mail to support leonics com or visit www leonics com To help you much more quickly when contact us please record the following information LEONICS UPS model Serial number of your UPS Purchased date Purchased from 1 1 General safety instruction 1 1 1 1 1 2 1 1 3 1 1 4 1 1 6 1 1 7 1 1 8 DO NOT work alone under hazardous condition Short circuit current in conductor may cause severe skin burn Must contact certified person when user
3. from your loads DO NOT connect utility power to UPS OUTPUT This may cause damage to your UPS When heavy rain please avoid using electronic instruments including UPS to prevent it from lightning 1 2 8 Use soft cloth to clean UPS when it is OFF DO NOT clean it with solvents 1 2 9 DO NOT use UPS with life recovery instruments The failure of UPS may cause life recovery instruments failure or effect to their performance or effect to safety system of those instruments 1 3 Warning Safety instruction for battery 1 3 1 There are batteries inside the UPS Although user has disconnected it from utility power line the UPS OUTLET or OUTPUT terminal are still has electricity Be careful of electric shock 1 3 2 The internal parts of UPS may conduct electric current which is dangerous to user UPS has no user serviceable parts DO NOT remove or disassemble any parts of the UPS If the user wants to repair the UPS contact us or our nearest service center 1 3 3 In case that user does not use or keep UPS for a long time to preserve the battery life please follow the below instruction 1 3 3 1 Turn off power switch and unplug input cable from power source 1 3 3 2 In case that user does not use UPS for along time User should re charge battery every 3 months by plugging the input cable to power source and turn the UPS on for at least 8 hours INTRODUCTION 2 1 General Leonics Ultimate X series UPS is a True On Line Double Conversion uninte
4. isplayed when UPS is malfunction Rear Panel Ultimate X 1000VA 1500VA model 3 2 1 3 2 2 3 2 3 3 2 4 3 2 5 3 2 6 Ultimate X 2000VA 3000VA model AC INPUT Connect power cord to this socket INPUT CIRCUIT BREAKER Protect UPS from overload or short circuit current OUTPUT Connect power to load at this outlet SMART RS 232 COMMUNICATION PORT Port to connect RS 232 cable to computer BATTERY EXTENSION PORT Port to connect battery extension modules for increase the duration of backup time SNMP AGENT option A port for connecting LAN line to computer interface network in order to monitoring the UPS status through SNMP HTTP see more details in the Net Agent II manual INSTALLATION 4 1 Connect computer network cable if any to RS 232 port of UPS 4 2 Plug in load cables to UPS OUTPUT 4 3 Plugin INPUT CABLE to wall outlet utility line 4 4 Incase of battery extension plug the cable from battery extension module into the UPS battery extension outlet Warning Be sure that the UPS has already plug in power line for 10 second before connecting battery extension Otherwise it may cause electrical spark OPERATION 5 1 Switch on 5 1 1 Under normal utility power line AC Start Plug in the power cord to the wall outlet Press the POWER ON button for 0 5 seconds then relea
5. off AUTO BYPASS and BATTERY LEVEL are blink and alarm sound alarms twice Utility voltage is too low or black out Press ALARM SILENCE button to mute alarm sound and then turn off loads before UPS shuts down LINE indicator is slow blink AUTO BYPASS is blink and alarm sound alarms twice Utility voltage is too low Press ALARM SILENCE button to mute alarm sound and then turn off loads before UPS shuts down When power return to normal turn it on again 11 Problem Cause Solution LINE indicator blinks fast AUTO BYPASS is blink and alarm sound alarms twice Utility voltage is too high Pree ALARM SILENCE to mute alarmsound and then turn off loads When power returns to normal turn it on again LOW BATTERY indicator blinks fast and alarm sound alarm continuously Battery are almost run out of power Turn off loads and UPS When power returns to normal turn it on again FAULT indicator is on and alarm sound alarms continuously There is something abnor mal inside the UPS Turn off UPS and then turn it on again If the problem is still there contact us or our nearest service center CUSTOMER SUPPORT If the UPS does not operate properly and you cannot solve the problem using the troubleshooting information in this users manual please contact your LEONICS local distributors LEONICS Service Center send e mail to support leonics com or visit
6. power fail but loads are normal MANUAL BYPASS SWITCH OPTION AC LINE INPUT CIRCUIT BREAKER BATTERY Above diagram shows how UPS works when utility power fail and UPS has less than 100 load UPS draws backup power from battery to invert to AC power and continuously supplies to load 2 2 4 Use maintenance bypass switch when UPS is malfunction option MANUAL BYPASS SWITCH OPTION TRANSFER SWITCH LOAD RECTIFIER INVERTER e INPUT CIRCUIT BREAKER N BATTERY Above diagram shows how system works when UPS is malfunction Useris allow to temporary run the system by turning the manual bypass switch from Auto to Bypass position All loads will get power supplied directly from utility line Then contact us or our nearest service center 3 1 Front panel 3 1 2 3 1 3 3 1 4 FRONT AND REAR PANEL 3 1 6 315 4 AWO BYPASS 3 1 4 3 1 3 Q s 3 4 7 LINE RECTIFIER INVERTER com ae a G g Banj a m mm ty LoaD ALARM SILENCE 3 1 8 O 2 tow Banery ON 311 319 tt O f OVERTENP POWER 3 4 10 A mw oF 3 1 2 POWER ON ALARM SILENCE Press this button to turn the UPS on and mute alarm sound POWER OFF Press this button to turn the UPS off LINE The indicator is displayed utility power status ON shows that input voltage is normal FAST BLINK
7. rruptible power supply which is the highest efficiency UPS system available in the present market It is able to protect all kinds of power problems and suitable for any power sensitive electrical appliance and electronic equipments such as computers com munication equipments medical instruments electronic scales measuring instruments scientific equipments and etc 2 2 How Leonics Ultimate X series UPS works 2 2 1 When utility power and loads are normal MANUAL BYPASS SWITCH OPTION TRANSFER SWITCH LOAD RECTIFIER INVERTER gt gt AE SO LINE A INPUT CIRCUIT BREAKER J BATTERY Above diagram shows how UPS works when utility power AC line is normal and UPS has less than 100 load UPS converts utility power from alternative current AC to direct current DC at RECTIFIER Some of the DC power flow to charge battery to be backup power and the rest flow directly to INVERTER to invert power to high quality and stable AC power Then supply to load 2 2 2 When utility power is normal but overload MANUAL BYPASS SWITCH OPTION TRANSFER SWITCH Load T Recmmen INVERTER l AC SO LINE INPUT CIRCUIT BREAKER l BATTERY Above diagram shows how UPS works when utility power is normal and UPS has more than 100 load UPS converts utility power at RECTIFIER to charge battery only The power supplied to load is from utility line 2 2 3 When utility
8. se The display panel will show the UPS status after that UPS will start up See details in section 3 1 5 1 2 Under power failure conditions DC start Press the POWER ON button for 0 5 seconds then release The display panel will show the UPS status after that UPS will start up with the power supply from batteries 5 2 Switch off 5 2 1 Under normal utility power line AC Start Press the POWER OFF button for 0 5 seconds All indicator lights will be off except the LINE indicator That means there is input voltage supplied to UPS for charging batteries 10 5 2 2 Under power failure conditions DC start Press the POWER OFF button for 0 5 seconds then release All indicator lights will be off TROUBLESHOOTING Problem Cause Solution Utility power is normal but UPS supplies backup power Power cord does not plug in properly Check power cord whether it is properly plug in at both wall out let and input socket When power fail UPS backs up but when power return to normal UPS still supplies backup power Utility voltage is too low Turn off loads and wait until utility voltage is normal Then turn on UPS and loads UPS is normal but over load indicator is on Loads connected to UPS is more than 100 UPS capacity Unplug some of the loads until load is about 75 the rest 25 is saving for some loads which may draw high current when operate LINE indicator is
9. wants to connect any equipment to utility power line Check whether the cables receptacles power source are always at good conditions To reduce short circuit risk if you are not sure whether you have ground system disconnect UPS from utility power every time before you connect any loads to UPS After connect all loads to UPS already then reconnect the UPS to utility power DO NOT touch any metal parts of the equipments when connected to UPS When connect or disconnect communication cables between equipments should use only one hand This is to avoid electric shock from contact 2 surfaces which ground has different potential voltage Recommend to connect UPS to 3 wire power source 2 poles ground which connects to branch circuit or fuse or automatic cut out 1 2 Caution Safety instruction for install and operate UPS 1 2 1 1 2 2 1 2 3 1 2 4 1 2 5 1 2 6 1 2 7 Should install UPS in dry area with good ventilation low humidity no chemical particles no flammable substances Avoid installing UPS near radio transmis sion station heat dissipation equipment or direct to sunlight UPS has ventilation grills on the back and sides To help UPS has good ventila tion DO NOT block ventilation grill Should connect UPS to utility line and turn on all the time When user wants to connect computer interface to UPS turn off power switch and disconnect cables from utility line Turn on UPS before turn on loads to prevent surge
10. www leonics com MAINTENANCE 8 1 Leonics UPS does not need any special maintenance Just only use it according to this user s manual and place it away from dusty and humid area Anyway if any of following items are is occurred please contact us or our nearest service center 8 1 1 Cable is cut or damaged 8 1 2 Wet with any liquids 8 1 3 UPS metal cabinet is broken 8 1 4 UPS is dropped fallen crashed or hit 8 2 8 3 8 4 12 8 1 5 User notices abnormal problems under normal operation Under normal operation and continuous use expected life time of ventilation fan is about 20 000 hours Even though the backup batteries are maintenance free type user still need to check them every year to make sure that they are still at good condition by following the procedure below 8 3 1 Turn on UPS 8 3 2 Turn on loads which are connected to UPS OUTPUT 8 3 3 Disconnect all loads from utility power and check whether the loads are still working normally 8 3 4 Ifthe loads are not working normally that means backup batteries are spoiled To get the new batteries contact us or our nearest service center For your safety please turn off the UPS and disconnect the UPS from utility power before maintenance