TACC User Manual
Contents
1. Accept the configuration by clicking OK The configured hardware is displayed in the Hardware Configuration window The newly added masters now have to be parameterized and activated 3 1 3 Master Parameterization Selecting the required master displays the current parameters Modify these according to your requirements and confirm your changes by clicking Apply Note Only masters with activated checkboxes are active bus stations For deactivated masters bus parameters are saved but the master is not active on the bus They can be activated at a later time Emerson Process Management 2014 All Rights reserved Page 7 of 21 User Guide HART Over PROFIBUS Hardware Configuration Tool r Configured Hardware thlink_O00300 E Gateway 1 thiink_000322 E Gateway 1 thlink_001690 E Gateway 1 thlink_002500 E Gateway 2 thlink_002733 E Gateway 2 thiink_000251 10 13 10 113 10 13 10 120 10 13 10 123 10 13 10 124 10 13 10 135 10 13 10 94 10 13 10 109 TH LINK PROFIBUS xEPI 2 TH LINK PROFIBUS xEPI 2 TH LINK PROFIBUS xEPI 2 TH LINK PROFIBUS xEPI 2 TH LINK PROFIBUS xEPI 2 TH LINK PROFIBUS xEPI 2 TH LINK PROFIBUS xEPI 2 Gateway Name IP Address thxepi2_000198 Activated Activated Activated Activated Activated Activated Parameters Station Activated M Address 3 z Baud Rate 1 5MBits v Line Name m Bus Parameters Profile DP X Tal 300 Min Ts
2. Configure the TH LINK PROFIBUS xEPI 2 units according to section 3 1 1 Start of the Hardware Configuration Tool to 3 1 38 Master Parameterization Hardware Configuration Tool Ea Station i thxepi2_000198 10 13 10 113 TH LINK PROFIBUS 7 xEPI 2 Acti cti thlink_O00300 10 13 10 120 TH LINK PROFIBUS xEPI 2 thlink_000322 10 13 10 123 TH LINK PROFIBUS xEPI 2 thlink_001690 10 13 10 124 TH LINK PROFIBUS X xEPI 2 ctivate Baud Rate C Gateway 1 thlink_002500 10 13 10 135 TH LINK PROFIBUS xEPI 2 Activated i oO Gateway 2 thlink_002733 10 13 10 94 TH LINK PROFIBUS xEPI 2 Activated C Gateway 2 thlink_000251 10 13 10 109 TH LINK PROFIBUS xEPI 2 Activated S ofti U Hardware Close Figure 9 Select redundancy partner Select the two TH LINK PROFIBUS xEPI 2 units that belong to the redundancy system To do so Click the first TH LINK PROFIBUS xEPI 2 unit hold down the Ctrl key and click the second TH LINK PROFIBUS xEPI 2 unit Click the Accept button to create a redundancy pair Note It is only possible to build a redundancy pair consisting of two TH LINK PROFIBUS xEPI 2 units It is possible to create a redundancy pair of two PROFIBUS masters from two different gateways but it is not recommended User Guide HART Over PROFIBUS The window Add Line Name opens Enter a Line Name for both PROFIBUS masters and click OK Add Line Name Please enter a line name for both PROFIBUS master BINAZOO Cancel Figure 10
3. new ones to a gateway if you have added new hardware with the Scan or Add functions before Note If you modify a gateway by removing a master that is part of a redundancy pair the redundancy partnership is also removed The line name of the remaining master of the former redundancy pair still displays Modify Gateway Ea thxepi2 000198 10 13 10 113 TH LINK PROFIBUS xEPI 2 thlink_O00300 10 13 10 120 TH LINK PROFIBUS xEPI 2 Device Illustration thlink_O00322 10 13 10 123 TH LINK PROFIBUS xEPI 2 thlink_001690 10 13 10 124 TH LINK PROFIBUS xEPI 2 thlink_002500 10 13 10 135 TH LINK PROFIBUS xEPI 2 HKA EA OK Cancel Figure 21 Modify Gateway 6 3 Deletion of Gateways To delete gateways open the Hardware Configuration tool and click Hardware Select a gateway in the Configured Hardware area and click Remove The gateway is deleted in the Configured Hardware area and all masters of this gateway are assigned to the Unconfigured Hardware area Note If you remove a gateway that is assigned to a redundancy pair the redundancy partnership is also deleted User Guide HART Over PROFIBUS 7 0 Modification and Deletion of Redundancy Pairs 7 1 Modify Redundancy Pairs It is not possible to modify a redundancy pair If you want to change a Line Name you must remove the redundancy and rebuild it with a new Line Name Note The entry for the Line Name must be unique If the entered Line Name already exists the OK button
4. Add Line Name Note The entry for the Line Name must be unique If the entered Line Name already exists the OK button is disabled Figure 11 The first selected TH LINK PROFIBUS xEPI 2 unit is displayed in the Configured Hardware list as the primary master and the second as backup Hardware Configuration Tool Configured Hardware _ Gateway Name __ IP Address Device Line Name C Gateway 1 thxepi2_000198 10 13 10 113 TH LINK PROFIBUS X xEPI 2 Activated oO Gateway 1 thlink_O00300 10 13 10 120 TH LINK PROFIBUS xEPI 2 81NA4200 primary Activated C Gateway 1 think_000322 10 13 10 123 TH LINK PROFIBUS xEPI 2 Activated oO Gateway 1 thlink_0016950 10 13 10 124 TH LINK PROFIBUS xEPI 2 81NA200 backup Activated C Gateway 1 thlink_002500 10 13 10 135 TH LINK PROFIBUS xEPI 2 Activated oO Gateway 2 thlink_002733 10 13 10 94 TH LINK PROFIBUS xEPI 2 Activated QO Gateway 2 thlink_000251 10 13 10 109 TH LINK PROFIBUS xEPI 2 Activated sONGS Figure 12 Redundancy Pair Emerson Process Management 2014 All Rights reserved Parameters Station Activated Address Baud Rate Line Name Bus Parameters Profile Tsl Min Tsdr Max Tsdr Ttr Tqui Tset Gap Retry limit HSA peisir ray Redundancy Pair Hardware Close Page 11 of 21 User Guide HART Over PROFIBUS 4 0 AMS Device Manager Network Configuration To use HART Over PROFIBUS with AMS Device Manager your PROFIBUS network nee
5. Hardware Es Configured Hardware Gateway Name IP Address Device ah All Unconfigured Hardware Add Scan S oft UU OK Cancel Figure 3 Add New Hardware The Configured Hardware area of the Add New Hardware window shows the gateways with configured masters In the Unconfigured Hardware area new masters can be searched for automatically or added manually If you want to identify the hardware automatically click Scan Existing masters are searched for and listed in the Unconfigured Hardware area This process can run for some time lf you want to add hardware manually click Add in the Unconfigured Hardware area This opens a window where you can select the hardware For TH LINK PROFIBUS xEPI 2 xEPI or PB XEPI you need to select TH LINK PROFIBUS xEPI 2 These units require entering host name or IP address Softing PROFIBUS Interface units require entering the Symbolic Node Name Add Hardware manually Hardware Selection f Host Name E he MEME ees REELE E TOUT Tee Hors OIP Addes a C Softing PROFIBUS Interface Add Cancel Figure 4 Add Hardware manually After adding the hardware the Add New Hardware window is displayed again All Softing PROFIBUS Interfaces and TH LINK PROFIBUS xEPI 2 units are listed in the Unconfigured Hardware area They need to be assigned manually to a gateway User Guide HART Over PROFIBUS Click Add in the Configured Hardware area to open the Add Gate
6. TAA A A E E A S E EE E calomel 20 9 2 FAN 810 1 rs 1110 LSet rst a rts Rt AST etn eRe eS aE en Eo ae ee ne ae 21 Emerson Process Management 2014 All Rights reserved Page 3 of 21 User Guide HART Over PROFIBUS 1 0 About this User Manual Please read this User Manual before you work with HART Over PROFIBUS It will help you with the configuration of master systems and will be useful for a better understanding of this application 2 0 HART Over PROFIBUS The HART Over PROFIBUS solution allows central access via Ethernet to all HART devices connected to the PROFIBUS by supported Remote I O RIO with HART functionality The HART devices are configured with the AMS Suite Intelligent Device Manager program For communication via PROFIBUS a class 2 master is required which is configured with the Hardware Configuration tool Detailed information on this can be found in the following sections 3 0 Hardware Configuration Tool With the Hardware Configuration tool you can configure PROFIBUS DP master systems which are required for communication via PROFIBUS softing PROFIBUS Interface TH LINK PROFIBUS xEPI 2 xEPI and Turck PB XEPI are supported Configuration is done in three to four steps a Search add the PROFIBUS DP master b c Parameterize activate the PROFIBUS DP master d Note Gateways are groups of masters of identical device types TH LINK PROFIBUS xEPI 2 xEPI and PB XEPI units are assigned to gateways of 1 to 12 devi
7. US xEPI 2 via IP address Why does AMS Device Manager Ensure that your master has been parameterized and activated show an empty network after a correctly depending on the cyclic master If not it will not be Rebuild Hierarchy registered in the PROFIBUS network or PROFIBUS failures might occur Why does AMS Device Manager In the Hardware Configuration tool there is a gateway show a gateway without configured but all assigned masters are deactivated or invalid segments Why does the start up of AMS HART Over PROFIBUS is designed with a 17 second time out Device Manager take so long to build up the connection to the hardware units If one of these units cannot be reached via TCP IP this time out situation occurs Please ensure that all inaccessible units are deactivated in the Hardware Configuration tool User Guide HART Over PROFIBUS Why does the hierarchy in AMS Device Manager not show a special Remote I O Why are process values highlighted in black in the AMS Device Manager process windows This can happen if there is no class 1 master in the PROFIBUS network of the missing Remote I O In this case it is possible to increase the time before HART Over PROFIBUS begins to communicate with the devices During this additional time the Remote I O has the chance to connect to the PROFIBUS network In the AMSTHInterface folder of the installation directory you can access the AMSTHinterface ini file Open this file and searc
8. User Guide HART Over PROFIBUS TACC HART Over PROFIBUS User Manual December 2014 Emerson Process Management 2014 All Rights reserved Page 1 of 21 User Guide HART Over PROFIBUS Emerson Process Management and Softing Industrial Automation GmbH Softing have collaborated to develop the HART Over PROFIBUS application for use with AMS Device Manager If you have any questions about the operation of the HART Over PROFIBUS application please contact the Emerson Global Service Center at E Mail ap sms ap emersonprocess com Internet htto www emersonprocess com systems support Emerson Process Management reserves the right to make changes and enhancements to this User Guide and or hardware and software specifications at any time and without prior or Subsequent notice Disclaimer The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability We reserve the right to modify or improve the designs or specifications of such products at any time without notice Copyright and Trademark Information Emerson Process Management 2014 All rights reserved The Emerson logo is a trademark and service mark of Emerson Electric Co AMS SNAP ON and ValveLink are marks of one of the Emerson group of c
9. a Communication Host 1 bix a Gateway 1 i TH LINKYxEPI 2 thxepi2_000690 IP 10 13 10 124 D TH LINKYxEPI 2 thxepi _000022 IP 10 13 10 123 D TH LINK xEFI 2 thxepi 000198 IP 10 113 10 113 aa D TH LINKYxEPI 2 thxepi2_000300 IP 10 13 10 120 ey D TH LINKYxEPI 2 thxepi2_001500 IP 10 113 10 135 te D TH LINKYxEPI 2 thlink_ 000733 IP 10 13 10 94 sani TH LINKYxEPI 2 thlink_O00051 IP 10 13 10 109 Ready ANDROMEDA Useradmin Figure 19 AMS Suite Intelligent Device Manager Device Connection View The following list explains AMS Device Manager elements Element Explanation O O O O o r Network name from AMS Device Manager Network Configuration Is the computer where TH AMS Device Manager Communication Components has been installed m Gateway 1 Shows the gateway that was created by the Set Bus Parameter program E g TH LINK xEPI 2 thlink 000051 IP 10 13 10 109 Master that has been assigned to a gateway in the Hardware Configuration Tool in this case for a TH LINK xEPI 2 lf the host name is not available the caption only shows TH LINK xEPI 2 IP 10 13 10 96 For the Softing PROFIBUS Interface the caption shows for example Softing PROFIBUS Interface 1 Symbolic Name eth User Guide HART Over PROFIBUS 6 0 Addition Modification and Deletion of Gateways 6 1 Addition of Gateways To add new hardware open the Hardware Configuration tool and click Hardware Search fo
10. ancel to go back to the Select Network Component Type dialog box gt Cancel Help Figure 16 Add HART Over PROFIBUS Wizard User Guide HART Over PROFIBUS Step 5 Select a name for your network This name will be displayed in AMS Device Manager fe General Enter a unique network name Network Name HART Over PROFIBUS lt Back Cancel Help Figure 17 Network Name Entry Step 6 Enter the name of the PC system or localhost in the DNS or IP Address field and deselect FOUNDATION Fieldbus Confirm with Finish fe Connection x Connection Parameters DNS or IP Address localhost Supported Devices Enable at least one of the following MV HART FOUNDATION Fieldbus Communication Timeout 30000 milliseconds PROFIBUS Diagnosis Browse lt Back Cance Help Figure 18 Connection With this last step parameterization of the PROFIBUS DP masters and their integration in AMS Device Manager is completed Emerson Process Management 2014 All Rights reserved Page 13 of 21 User Guide HART Over PROFIBUS 5 0 Display in AMS Device Manager The server component for all gateways runs on the local AMS Device Manager server with the name of the PC system or localhost 4 AMS Suite Intelligent Device Manager Device Connection View eel ra File Edit View Tools Window Help E x Sie ele a a l la r HART Over PROFIBUS cee o
11. ces each Assign the master to a gateway Create redundancy pair only for redundant systems supported hardware see Release Notes Use of the user interface and configuration of the PROFIBUS DP master will be explained in the following sections User Guide HART Over PROFIBUS 3 1 Step by Step Guide to Master Configuration 3 1 1 Start of the Hardware Configuration Tool Select Softing Hardware Configuration as shown in Figure 1 Apps Photos Weather j Internet Information Services IIS Pictures gt Windows Media Player Hardware Configuration Reader Installation Guide TACC Reading List Release Note User Guide TACC Figure 1 Start Menu 3 1 2 Hardware Selection The Hardware Configuration window displays all previously configured hardware Click the Hardware button for hardware addition and modification Hardware Configuration Tool r Configured Hardware Parameters Gateway Name IP Address Device LineName RedPat Activated ie Activated D Address sd Baud Rate J Line Name m Bus Parameters Profile zl Tsl oOo i i zs MinTsd f Max Tsdr Th igh Tset isd Gap Retry limit i id HSA m Redundancy Pair i oft INAS Hardware Close Figure 2 Hardware Configuration Tool Emerson Process Management 2014 All Rights reserved Page 5 of 21 User Guide HART Over PROFIBUS The Add New Hardware window opens Add New
12. dr e Max Tsdr 150 Ttr 25 Tqui O E E Gap it Retry limit E m Redundancy Pair softiiig Hardware Close Figure 6 Hardware Configuration Activated You can choose between three default profiles DP Bus Parameters Profile a Gap Retry limit HSA Bus Parameter Test Apply Universal FDL FMS Bus Parameters Protile Universal FOL FRMS Tal S000 150 Lap Retry limit HSA Bus Parameter Test Apply User Defined Bus Parameters Profile User Defined Gap Retry limit HSA Bus Parameter Test Apply Figure 7 Default Profiles Activated User Guide HART Over PROFIBUS DP Profile In this profile you can exclusively modify the HSA value Universal Profile FDL FMS In this profile also only the HSA value can be changed Baud rates 45 45 kBit s 3 MBit s 6 MBit s and 12 MBit s are not supported in this profile User Defined Profile In this profile you can modify further bus parameters Click the respective description field and enter your settings To check the entered bus parameters you can use the Bus Parameter Test In case of errors the incorrect values are marked with an exclamation mark Info Error eA Eren F The specified address is already in use on the PROFIBUS ee Nah Please change the settings and repeat the Bus Parameters Test Figure 8 Bus Parameter Test result Attention We strongly r
13. ds to be set up in the AMS Device Manager Network Configuration Proceed through the configuration as follows Desktop Gadget Galley Step 1 Open Network Configuration i Internet Explorer amp Windows Anytime Upgrade wa 4 Windows DVD Maker a Windows Fax and Scan Install Windows Media Center Windows Media Player amp Windows Update A XPS Viewer di Accessories Ap AMS Device Manager Add Device Type gi AMS Device Manager Eea Network Configuration 30 Station Configuration fy Terminate Servers User Manager di Database Utilities di Help di Licensing Documents Pictures Computer Control Panel Devices and Printers Default Programs Help and Support Figure 13 Start Network Configuration Step 3 Select the HART Over PROFIBUS Network type and confirm with Install Select Network Component Type Click the type of network component pou want to install S000 BIM HAART Modem Multiplexer Network Wireless Network FF HSE Network Calibrator HART Over PROFIBUS Stahl Network 4 mn Figure 15 Select Network Component Type Step 2 Add a new network with Add twork Configuration The following network components are installed Remove Properties Figure 14 Network Configuration Step 4 Click Next to install the HART Over Click Next to begin installing a HART Over PROFIBUS Network Click C
14. ecommend use of these standard profiles on all masters in the PROFIBUS network Manual bus parameter setting requires thorough PROFIBUS knowledge Further information on bus parameters can be found in 9 0 Terms and Abbreviations Masters can be in one of the following states Activated Activated status means that the master is completely configured and parameterized This master can be used in AMS Device Manager Deactivated Deactivated status means that the master is completely configured and needs to be parameterized and activated However this master cannot be used in AMS Device Manager Invalid Invalid status means a master has been added manually by entering its host name but the IP address cannot be identified by the host name Masters in the Invalid state cannot be parameterized When all masters are parameterized click the Close button to close the Hardware Configuration tool Settings are adopted with the next start of AMS Device Manager Emerson Process Management 2014 All Rights reserved Page 9 of 21 User Guide HART Over PROFIBUS 3 1 4 Create Redundancy Pair This function is only available for TH LINK PROFIBUS xEPI 2 units For a redundant system one TH LINK PROFIBUS xEPI 2 unit has to be in the primary line and another TH LINK PROFIBUS xEPI 2 unit has to be in the backup line of your PROFIBUS network The supported hardware for redundant systems is listed in the release notes for TH AMS Communication Components
15. h for WaitAfterMasterStart and assign the time in seconds that should elapse before communication default value 0 e g WaitAfterMasterStart 5 the wait time is five seconds 1 The HART device is not accessible Please check physical connections to the HART device 2 Some devices are not capable of responding to several HART requests concurrently HART requests are processed consecutively which requires more time Increase the Communication Timeout in AMS Device Manager Network Configuration see Figure 16 A time out period of 30000 milliseconds per open process window is recommended Emerson Process Management 2014 All Rights reserved Page 19 of 21 User Guide HART Over PROFIBUS 9 0 Terms and Abbreviations 9 1 Terms Abbreviation Ts Slot Time This time determines the maximum time the sender waits for a response from the addressed station Min Tsdr Min Station Delay Responder The time that the slave must wait before it may respond to a request from the master In the standard 11 Tbit is defined Max Tsdr Max Station Delay Responder The time in which the slave must respond to are request from the master of the latest The value range is between 60 and 800 Tbit here depending on transfer rate Target Rotation Time This time is the maximum time available for one Token rotation In this time span all DP masters receive the Token once Tqui Quiet Time for Modulator This is the time a
16. is disabled 7 2 Remove Redundancy Pairs To delete a redundancy pair you have to select both PROFIBUS masters of the redundancy pair Click the first TH LINK PROFIBUS xEPI 2 unit hold down the Ctrl key and click the second TH LINK PROFIBUS xEPI 2 unit Click the Remove button to delete the redundancy partnership Hardware Configuration Tool ea Configured Hardware Parameters Station Name IP Address Device Line Name Activated thxepi2_000198 10 13 10 113 TH LINK PROFIBUS xEPI 2 Activated Activated a thlink_000300 10 13 10 120 TH LINK PROFIBUS sEPI 2 81NA200 primary Activated Adina isd thlink_000322 10 13 10 123 TH LINK PROFIBUS xEPI 2 Activated thlink_001690 10 13 10 124 TH LINK PROFIBUS xEPI 2 81NA200 Activated Baud Rate oO Gateway 1 thiink_002500 10 13 10 135 TH LINK PROFIBUS xEPI 2 Activated eee rT oO Gateway 2 thlink_002733 10 13 10 94 TH LINK PROFIBUS xEPI 2 Activated O Gateway 2 thlink_000251 10 13 10 109 TH LINK PROFIBUS xEPI 2 Activated Bus Parameters Profile Tsl Min Tsdr Max Tsdr Ttr Tqui Tset Gap Retry limit HSA Redundancy Pair Remove S oft IU Hardware Close Figure 22 Remove Redundancy Pair Emerson Process Management 2014 All Rights reserved Page 17 of 21 User Guide HART Over PROFIBUS 8 0 FAQ Why is the Configured Hardware No hardware has been configured Click Hardware and add the window empty after starting the new ha
17. ompanies HART is a registered trademark of the HART Communications Foundation of Austin Texas USA FOUNDATION is a mark of the Fieldbus Foundation of Austin Texas USA All other marks are property of their respective owners User Guide HART Over PROFIBUS TABLE OF CONTENTS 1 0 About this User Manual acerca a a a 4 20 MAHART Over PROFIBUS sicitesttavidoutiaridentderidenideridenidacidenidaadanddesdanddaunenidanidenadaebbestiael 4 3 0 Hardware Configuration TOO cccccccccceccccsececceeeeeseeseseeeeeeseeeesseeeesseeeesseeeesaeeeesaeeees 4 3 1 Step by Step Guide to Master Configuration cccccccccccceeseeeeceeeeceesseeeeeeseeeeeeeeeaeeeeeaas 5 3 1 1 Start of the Hardware Configuration TOO cccccccesescececeeeeeeeeseeeceeeeeseeeeseeeeeeeeessaeaseeeeeeeeeesaas 5 Sele Mardware Sel SCION eein a adie oer anncteaktwuaauneawetamaetes 5 Sho Master Parameterization inci xiseicuseitocntiicecuinindaee ache dhedenawacetend a e a 7 3 1 4 Create Redundancy Pair cccccccsssssececcceseeeccceeeseceecceeueeeeesseuseceeseuaaseceesssageeeesssuaeeesessaagss 10 4 0 AMS Device Manager Network Configuration cccccceccecseeeeseeeeeeeeeeeseeeeesaeeeesaees 12 Step 1 Open Network Configuration ccccccccccccsesssseeceeeeecseeeeeeeeeeeeeeseeesseeeeeeesssseaaseseeeeeessaaaaeeeeeees 12 Step 2 Add a new network with Add cccccccccssseseeeceeeeeceaeeseeeeeeeeessaeeesseeeeeeessuaaaeeeeeeese
18. r new hardware with the Scan function or add the hardware manually Softing PROFIBUS Interfaces and TH LINK PROFIBUS xEPI 2 units are listed in the Unconfigured Hardware area Click Add in the Configured Hardware area to include the hardware units in a new gateway Enter a new name for the gateway and move the required hardware units from the Unassigned to the Assigned area Confirm with OK Afterwards the new masters have to be parameterized as described in 3 1 38 Master Parameterization Add Gateway EJ Gateway Assigned Unassigned IPAddress Device thlink_002733 10 13 10 94 TH LINK PROFIBUS 7 xEPI 2 thlink_000251 10 13 10 109 TH LINK PROFIBUS 7 xEPI 2 thxepi2 000198 10 13 10 113 TH LINK PROFIBUS xEPI 2 thlink_000300 10 13 10 120 TH LINK PROFIBUS xEPI 2 i 10 13 10 123 TH LINK PROFIBUS xEPI 2 a 10 13 10 124 TH LINK PROFIBUS xEPI 2 thlink_002500 10 13 10 135 TH LINK PROFIBUS xEPI 2 A w oo oo os 5 m oO On on OK Cancel Figure 20 Add Gateway Emerson Process Management 2014 All Rights reserved Page 15 of 21 User Guide HART Over PROFIBUS 6 2 Modification of Gateways To modify existing gateways open the Hardware Configuration tool and click Hardware Select a gateway in the Configured Hardware area and click Modify This opens the Modify Gateway window The gateway name and the used masters are displayed You can change the gateway name for all gateway types You can delete masters or add
19. rdware see 3 1 2 Hardware Selection Bus parameters Hardware Configuration tool All are only displayed when a master has been selected bus parameter fields are gray Why is there no hardware in the No hardware units are available in the network or they cannot Unconfigured Hardware area be identified automatically Hardware units can only be located after scanning automatically if the search process is not blocked by firewall settings or similar security settings If the hardware units cannot be searched automatically they have to be inserted by manual addition and IP address entry How many hardware units can Up to 12 hardware units can be assigned to one gateway assign to one gateway Why are no masters listed in the Only configured masters are saved when terminating the Unconfigured Hardware area program Unconfigured hardware is no longer displayed after after starting the Hardware program restart It has to be added again Configuration tool Why is a master listed as Invalid The Invalid status is assigned to a master if it has been added after manually adding the TH LINK manually by entering its host name but the IP address cannot PROFIBUS xEPI 2 unit via host be identified by the host name This could be caused by the fact name that there is no active DNS server or if the TH LINK PROFIBUS xEPI 2 with statically set IP address has not been logged on at the DNS server In this case you need to add your TH LINK PROFIB
20. ssaaaaseeeeeees 12 Step 3 Select the HART Over PROFIBUS Network type and confirm with Install 00 12 Step 4 Click Next to install the HART Over PROFIBUS Network cccsssseeeeeeeeeeeeeessaeeeeeeeeeas 12 Step 5 Select a name for your network This name will be displayed in AMS Device Manager 13 Step 6 Enter the name of the PC system or localhost in the DNS or IP Address field and deselect FOUNDATION Fieldbus Confirm with Finish 0 cccccssececeeeeeceseeeeeneeeeeaeeseeeeteaeeetegeeeneaeeees 13 5 0 Display in AMS Device Managel cccccsecccsscccseeeceececeuceceusecsusecsusessusessusesueenaaees 14 6 0 Addition Modification and Deletion of Gateways cccccccesseeseeeceeeeseeeeseeeesaeees 15 6 1 Addition OF GaleWay S cccanscctiioscbietdisd cecos cece pouch nN ate ce eases Lender eebeiciuaele 15 6 2 MOGITICATION ol GAlew ay Saiscc secon eit hceahe ecw etn ane hatciee Ad aot a tiie tec te 16 6 3 DElEtION Ol Gale Way Sciatic hectic tole E E eden tlec eects 16 7 0 Modification and Deletion of Redundancy Pairs ccccccsecceeeceeeeeeeeseeeseeeeaeeenaees 17 7 1 Modify AEGUAGANCY Pall Sesuo slices a e eatellat acon Caliataiad 17 7 2 Remove Redundancy PAINS 21 cccsueccte ete dactarenatceuha E E ceutiesenchaids 17 Do gy eee ee iN MPEG CROP Cate ROVER OT Cera UY Un Rare Say NS 18 90 Teme and 218 8 ic 110 seer ee eer ne er ee ee 20 9 1 RSs Seely E cee E E EAE A
21. station needs for switching from sending to receiving after telegram end Tset Setup Time This is the time that may pass between receiving a data telegram and the respective reaction within a station Gap GAP Update Factor Specifies after how many bus rotations the master searches for new active stations in order to include them in the bus and be able to pass the token on to that station The GAP area is between the own station address and the next one exception the area of the highest station address up to address 127 does not belong to the GAP area Retry limit Maximum Number of Call Retries Determines the maximum number of telegram retries carried out to reach a station Highest Station Address States the highest valid station address in the PROFIBUS network User Guide HART Over PROFIBUS 9 2 Abbreviations Decentralized Periphery Explanation Fieldbus Message Specification FMS can be operated together with DP Emerson Process Management 2014 All Rights reserved Page 21 of 21
22. way window Add Gateway Ex Gateway Assigned Unassigned Gateway 1 Host Name IP Address Device Host Name IP Address Device thxepi2 000198 10 13 10 113 TH LINK PROFIBUS xEPI 2 thlink_002733 10 13 10 94 TH LINK PROFIBUS xEPI 2 thlink_000300 10 13 10 120 TH LINK PROFIBUS xEPI 2 thlink_000251 10 13 10 109 TH LINK PROFIBUS xEPI 2 Device Illustration thlink_000322 10 13 10 123 TH LINK PROFIBUS xEPI 2 thlink_001690 10 13 10 124 TH LINK PROFIBUS xEPI 2 thlink_002500 10 13 10 135 TH LINK PROFIBUS xEPI 2 HA We OK Cancel Figure 5 Add Gateway Define the name for the Gateway and select the respective hardware units for this gateway To do this highlight the respective hardware units and move them to the Assigned area You can assign a maximum of 12 hardware units to one gateway Note Only the same hardware unit types can add to one gateway That means either Softing PROFIBUS Interfaces or TH LINK PROFIBUS xEPI 2 units Confirm with OK and the gateway will be shown in the Configured Hardware area Assigned masters are displayed for the selected gateway To change the gateway select it and click Modify Gateway name as well as the assigned masters can be modified To delete a gateway select it and click Remove All masters assigned to the respective gateway are moved to the Unconfigured Hardware area Further details on this are included in section 6 0 Addition Modification and Deletion of Gateways